Search NASA⌕ Search

SEARCH · Search NASA

Results for “load analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Temporal Decompostion of a Distribution System Quasi-Static Time-Series Simulation

This paper documents the first phase of an investigation into reducing runtimes of complex OpenDSS models through parallelization. As the method seems promising, future work will quantify - and further mitigate - errors arising from this process. In this initial report, we demonstrate how, through the use of temporal decomposition, the run times of a complex distribution-system-level quasi-static time series simulation can be reduced roughly proportional to the level of parallelization. Using this method, the monolithic model runtime of 51 hours was reduced to a minimum of about 90 minutes. As expected, this comes at the expense of control- and voltage-errors at the time-slice boundaries. All evaluations were performed using a real distribution circuit model with the addition of 50 PV systems - representing a mock complex PV impact study. We are able to reduce induced transition errors through the addition of controls initialization, though small errors persist. The time savings with parallelization are so significant that we feel additional investigation to reduce control errors is warranted.

14 SOLAR ENERGY↗

Performance Analysis of Li-ion Battery Under Various Thermal and Load Conditions

In the recent years, with the rapid advancements made in the technologies of electric and hybrid electric vehicles, selecting suitable batteries has become a major factor. Among the batteries currently used for these types of vehicles, the lithium-ion battery leads the race. Apart from that, the energy gained from regenerative braking in locomotives and vehicles can be stored in batteries for later use for propulsion thus improving the fuel consumption and efficiency. But batteries can be subjected to a wide range of temperatures depending upon the operating conditions. Thus, a thorough knowledge of the battery performance over a wide range of temperatures and different load conditions is necessary for their successful employment in future technologies. In this context, this study aims to experimentally analyze the performance of Li-ion batteries by monitoring the charge–discharge rates, efficiencies, and energy storage capabilities under different environmental and load conditions. Sensors and thermal imaging camera were used to track the environment and battery temperatures, whereas the charge–discharge characteristics were analyzed using CADEX analyzer. The results show that the battery performance is inversely proportional to charge–discharge rates. This is because, at higher charge–discharge rates, the polarization losses increase thus increasing internal heat generation and battery temperature. Also, based on the efficiency and energy storage ability, the optimum performing conditions of the Li-ion battery are 30–40 °C (temperature) and 0.5 C (C-rate).

25 ENERGY STORAGE↗

Hybrid-RL-MPC4CLR (Hybird-Reinforcement-Learning-Model-Predictive-Control-for-Reserve-Policy-Assisted-Critical-Load-Restoration-in-Distribution-Grids)

Hybrid-RL-MPC4CLR was developed as a hybrid controller for active distribution grid critical load restoration, combining deep reinforcement learning (RL) and model predictive control (MPC) aiming at maximizing total restored load following an extreme event. The RL determines a policy for quantifying operating reserve requirements, thereby hedging against uncertainty, while the MPC models grid operations incorporating the RL policy actions (i.e., reserve requirements), renewable (wind and solar) power predictions, and load demand forecasts. The developers formulated the reserve requirement determination problem as a sequential decision-making problem based on the Markov Decision Process (MDP) and design an RL learning environment based on the OpenAI Gym framework and MPC simulation. The RL agent reward and MPC objective function aim to maximize and monotonically increase total restored load and minimize load shedding and renewable power curtailment. The software is developed using various software packages in Python. The MPC's optimal power flow (OPF) model is implemented using the Pyomo package, the RL simulation environment is implemented using the MPC simulation with various scenarios of renewable energy and load demand profiles and power outage beginning times, based on the OpenAI Gym framework. The RL agent training is performed using the RLlib Ray package. The RL algorithm is trained offline using historical forecasts of renewable generation and load demand profiles. Simulation analysis and performance tests are conducted using a modified IEEE 13-bus distribution test feeder containing wind turbine, photovoltaic, microturbine, and battery.

Eseye, Abinet Tesfaye↗

DEEPEN Global Standardized Categorical Exploration Datasets for Magmatic Plays

DEEPEN stands for DE-risking Exploration of geothermal Plays in magmatic ENvironments. As part of the development of the DEEPEN 3D play fairway analysis (PFA) methodology for magmatic plays (conventional hydrothermal, superhot EGS, and supercritical), weights needed to be developed for use in the weighted sum of the different favorability index models produced from geoscientific exploration datasets. This was done using two different approaches: one based on expert opinions, and one based on statistical learning. This GDR submission includes the datasets used to produce the statistical learning-based weights. While expert opinions allow us to include more nuanced information in the weights, expert opinions are subject to human bias. Data-centric or statistical approaches help to overcome these potential human biases by focusing on and drawing conclusions from the data alone. The drawback is that, to apply these types of approaches, a dataset is needed. Therefore, we attempted to build comprehensive standardized datasets mapping anomalies in each exploration dataset to each component of each play. This data was gathered through a literature review focused on magmatic hydrothermal plays along with well-characterized areas where superhot or supercritical conditions are thought to exist. Datasets were assembled for all three play types, but the hydrothermal dataset is the least complete due to its relatively low priority. For each known or assumed resource, the dataset states what anomaly in each exploration dataset is associated with each component of the system. The data is only a semi-quantitative, where values are either high, medium, or low, relative to background levels. In addition, the dataset has significant gaps, as not every possible exploration dataset has been collected and analyzed at every known or suspected geothermal resource area, in the context of all possible play types. The following training sites were used to assemble this dataset: - Conventional magmatic hydrothermal: Akutan (from AK PFA), Oregon Cascades PFA, Glass Buttes OR, Mauna Kea (from HI PFA), Lanai (from HI PFA), Mt St Helens Shear Zone (from WA PFA), Wind River Valley (From WA PFA), Mount Baker (from WA PFA). - Superhot EGS: Newberry (EGS demonstration project), Coso (EGS demonstration project), Geysers (EGS demonstration project), Eastern Snake River Plain (EGS demonstration project), Utah FORGE, Larderello, Kakkonda, Taupo Volcanic Zone, Acoculco, Krafla. - Supercritical: Coso, Geysers, Salton Sea, Larderello, Los Humeros, Taupo Volcanic Zone, Krafla, Reyjanes, Hengill. **Disclaimer: Treat the supercritical fluid anomalies with skepticism. They are based on assumptions due to the general lack of confirmed supercritical fluid encounters and samples at the sites included in this dataset, at the time of assembling the dataset. The main assumption was that the supercritical fluid in a given geothermal system has shared properties with the hydrothermal fluid, which may not be the case in reality. Once the datasets were assembled, principal component analysis (PCA) was applied to each. PCA is an unsupervised statistical learning technique, meaning that labels are not required on the data, that summarized the directions of variance in the data. This approach was chosen because our labels are not certain, i.e., we do not know with 100% confidence that superhot resources exist at all the assumed positive areas. We also do not have data for any known non-geothermal areas, meaning that it would be challenging to apply a supervised learning technique. In order to generate weights from the PCA, an analysis of the PCA loading values was conducted. PCA loading values represent how much a feature is contributing to each principal component, and therefore the overall variance in the data.

15 GEOTHERMAL ENERGY↗

Simulating the Value of Concentrating Solar Power with Thermal Energy Storage in a Production Cost Model

Concentrating solar power (CSP) deployed with thermal energy storage (TES) provides a dispatchable source of renewable energy. The value of CSP with TES, as with other potential generation resources, needs to be established using traditional utility planning tools. Production cost models, which simulate the operation of grid, are often used to estimate the operational value of different generation mixes. CSP with TES has historically had limited analysis in commercial production simulations. This document describes the implementation of CSP with TES in a commercial production cost model. It also describes the simulation of grid operations with CSP in a test system consisting of two balancing areas located primarily in Colorado.

14 SOLAR ENERGY↗

Impacts of Regional Electricity Prices and Building Type on the Economics of Commercial Photovoltaic Systems

To identify the impacts of regional electricity prices and building type on the economics of solar photovoltaic (PV) systems, 207 rate structures across 77 locations and 16 commercial building types were evaluated. Results for expected solar value are reported for each location and building type. Aggregated results are also reported, showing general trends across various impact categories.

14 SOLAR ENERGY↗

Simulation of Wind Turbine Performance and Loading Patterns using a Coupled Meso-scale/Micro-scale Flow Analysis Model

HELIOS simulations were conducted for the WPS-30 turbine from the Sexbierum experimental site. The MMCI module was used to include the effects of the atmospheric boundary layer using the strategy described in the methodology section. In Figure 1 , the thrust and power variation for the WRF/Helios (Meso-scale/micro-scale simulation) is compared with measured power and stand-alone Helios computations (uniform inflow). The unsteady variations in power and thrust caused by the turbulent inflow conditions is clearly evident from these figures. Note that the mean hub height velocity could not be exactly matched to the uniform inflow values of 8 m/s because of constraints in adjusting the geostrophic wind and roughness length in Meso-scale WRF simulations. The offset in mean power and thrust notable in the figures are because of the small difference in the mean wind speed. Nonetheless, these results provide proof-of-concept of the integrated Meso-scale/Micro-scale simulation capability developed as part of this work. To further substantiate the effects of turbulent inflow, flow visualizations (iso-surfaces of vorticity overlaid on contours of velocity magnitude) are shown in Figure 2 . Meandering of the vortex wake and eventual breakdown are observed in the flow visualizations. Vortex breakdown is observed to occur between 1.5 and 2.5 diameter distance from the turbine. In uniform inflow (not shown here), the vortex wake persists to much longer distance of about 5 diameters before beginning to breakdown. It is expected that the vortex breakdown will be strongly correlated with the turbulence intensity of the inflow. The capability developed herein provides enabling technology for analyzing and characterizing such effects.

17 WIND ENERGY↗

Electrochemical Behaviors of Bilayer Oxygen Electrode for Reversible Solid Oxide Cells

Reducing the resistances of oxygen reduction reaction (ORR) and oxygen evolution reaction (OER) while retaining the stability of an oxygen electrode, even in the presence of air contaminants such as Cr, H2O and CO2, is of paramount importance to the current commercial development of intermediate-temperature reversible solid oxide cells (IT-RSOCs). In this presentation, a multifunctional, coarsening-resistant, air-contaminants-tolerant and yet ORR/OER-active oxygen electrode (OE) for IT-RSOCs is described. The testing results show that new bilayer OE exhibits a much better ORR/OER activity and stability than the single-layer benchmark LSCF-GDC OE. Remarkably, the new bilayer OE also demonstrates an exceptionally high resistance to Cr-attack, a critical issue to the development of commercial meal-interconnect loaded SOFC/SOEC stacks/systems. Theoretical analysis is also presented to understand the fundamental reasons for the improved ORR/OER activity and stability observed under real-world operating conditions.

Huang, Kevin↗

Energy Transitions Initiative Partnership Project: City and Borough of Sitka, Alaska - Modeling and Controls Assistance and Renewable Energy Resource Assessment [Slides]

This presentation provides a summary of the ETIPP project objectives and findings for Sitka, Alaska, including sizing of wind penetration, dynamic models, and analysis of efficiency of load control, stability and grid control impacts of wind capacity expansions and locations, and wind-hydro control coordination.

17 WIND ENERGY↗

High Power Solid Target for Positron Source at CEBAF

The progress in the development of a polarized positron injector for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory is presented. The polarized positron beam is generated by a high current polarized electron beam (>1 mA @ 120 MeV) via bremsstrahlung radiation and e+e- pair production in the tungsten target. The simulations show that using an optimized target and positron beamline, the positron injector can provide a cw positron beam with a current larger than 50 nA and a polarization as large as 60%. Injected into the North Linac of CEBAF at an energy of 123 MeV, the positron beam can reach a maximum energy of 12 GeV to perform a rich experimental program. The results of the thermal and structural FEA analysis of the heat load in the target are presented, as well as the simulation results of radiation damage in the target. The performed and planned target material fatigue and radiation damage tests are discussed. This work is supported by the U.S. DOE, Office of Science, Office of Nuclear Physics, Contract No. DE-AC05-06OR23177 and the European Union?s Horizon 2020 research and innovation program under grant agreement No. 824093.

Ushakov, Andriy↗

Improving Cost and Efficiency of the Scalable Solid Oxide Fuel Cells Power System

The objective of this project was to design and develop a 20kW range small-scale solid oxide fuel cells (SOFC) power system for applications such as data centers and commercial buildings. The original plan included a 5,000 hours demonstration and a Techno-Economic Analysis (TEA) which were dropped as part of project termination. The original project plan was to use a stack with a cross-flow cell design which had previously been tested for 500 hours at a community college in Malta, NY. However, it was decided to move to the advanced R-SOFC co-flow cell developed under Department of Energy Award DE-FE0031971. The advanced cell design has the advantage of a larger active area for the same manufacturing footprint which results in fewer required cells for the same stack power, hence a higher volumetric power density (kW/L) and lower cost per kW than the original cross-flow cell design. A full SOFC system Simulink model was developed and calibrated with testing data from a fuel cell stack and BOP (balance of plant) components. The simulation results from the calibrated model showed an acceptable match with the experimental data. A structural analysis conducted for various load scenarios indicated no high stress areas for all spatial directions. Major electrical system components were acquired, built and successfully tested. System sensors were verified and validated against controls. Safety checks, a diagnostic check, PID tuning, and control software commissioning tasks were also conducted. The power electronics prototype was delivered and trial testing completed. Balance of Plant component testing and simulation work was conducted to characterize Reformer-Heat Exchanger heat transfer and backpressure and reformer catalyst methane conversion and product selectivity. Simulations were conducted to design the Anode and Cathode fluid passages and size the air-air and fuel-fuel heat exchangers. A Burner operation map was created from test data and the Anode Gas Recirculation blower was tested to evaluate its durability. The SOFC system used a horizontal style design where components sit directly on a casting with a direct connection to the skid. This design has efficient packaging and a small footprint with approximate dimensions of 750 mm x 700 mm x 1700 mm. An SOFC system was built and successfully tested at the Malta, NY facility The system for over 500 hours under load of which over 300 hours was at full load of 20 kW.

30 DIRECT ENERGY CONVERSION↗

Design and Development of the PIP-II Stripline Beam Position Monitor

• Designed a stripline Beam Position Monitor (BPM) for the PIP-II accelerator to ensure precise proton beam alignment under ultra-high vacuum (UHV) conditions • Developed a mechanically robust and manufacturable assembly, including a cylindrical housing, electrodes, flange interfaces, and internal supports • Achieved high safety margins under pressure loading, using finite element analysis (FEA), while

Avalos Angel, Alejandro [Northern Illinois U.]↗

Optimal Upsetting of Composite Cylinders

The upsetting of a composite cylinder in frictionless creep is analyzed in energy terms. Three loading programs that lead to upsetting of the cylinder by the same amount in the same time are compared. Variational analysis indicates that the kinematic loading program is best for industrial use.

42 ENGINEERING↗

A Conceptual Framework to Describe Energy Efficiency and Demand Response Interactions

Energy efficiency (EE) and demand response (DR) resources provide important utility systems and ratepayer benefits. At the same time, the rapid change in the amount and type of variable renewable energy, like solar and wind, is reshaping the role and economic value of EE and DR, and will likely affect the time-dependent valuation of EE and DR measures. Utilities are increasingly interested in integrating EE and DR measures as a strategic approach to improve their collective cost-effectiveness and performance. We develop a framework to identify the EE and DR attributes, system conditions, and technological factors that are likely to drive interactions between EE and DR. We apply the framework to example measures with different technology specifics in the context of different utility system conditions. We find that EE and DR interactions are likely driven by changes in discretionary load, the addition of controls or other capabilities to shift loads, and the coincidence of savings with system peak or load building periods. Our analysis suggests increasing complexity in evaluating EE and DR interactions when moving from standalone equipment to integrated systems. The framework can be applied to research on integrated building systems by grouping measures into portfolios with different likely implications for EE and DR interactions.

Satchwell, Andrew J. (ORCID:0000000244053599)↗

A Wave Energy Converter Design Load Case Study

This article presents an example by which design loads for a wave energy converter (WEC) might be estimated through the various stages of the WEC design process. Unlike previous studies, this study considers structural loads, for which, an accurate assessment is crucial to the optimization and survival of a WEC. Three levels of computational fidelity are considered. The first set of design load approximations are made using a potential flow frequency-domain boundary-element method with generalized body modes. The second set of design load approximations are made using a modified version of the linear-based time-domain code WEC-Sim. The final set of design load simulations are realized using computational fluid dynamics coupled with finite element analysis to evaluate the WEC’s loads in response to both regular and focused waves. This study demonstrates an efficient framework for evaluating loads through each of the design stages. In comparison with experimental and high-fidelity simulation results, the linear-based methods can roughly approximate the design loads and the sea states at which they occur. The high-fidelity simulations for regular wave responses correspond well with experimental data and appear to provide reliable design load data. The high-fidelity simulations of focused waves, however, result in highly nonlinear interactions that are not predicted by the linear-based most-likely extreme response design load method.

16 TIDAL AND WAVE POWER↗

The Reduced Effectiveness of EGR to Mitigate Knock at High Loads in Boosted SI Engines

Numerous studies have demonstrated that exhaust gas recirculation (EGR) can attenuate knock propensity in spark ignition (SI) engines at naturally aspirated or lightly boosted conditions. In this paper, we investigate the role of cooled EGR under higher load conditions with multiple fuel compositions, where highly retarded combustion phasing typical of modern SI engines was used. It was found that under these conditions, EGR attenuation of knock is greatly reduced, where EGR doesn’t allow significant combustion phasing advance as it does under lighter load conditions. Detailed combustion analysis shows that when EGR is added, the polytropic coefficient increases causing the compressive pressure and temperature to increase. At sufficiently highly boosted conditions, the increase in polytropic coefficient and additional trapped mass from EGR can sufficiently reduce fuel ignition delay to overcome knock attenuation effects. Kinetic modeling demonstrates that the effectiveness of EGR to mitigate knock is highly dependent on the pressure-temperature condition. Experiments at 2000 rpm have confirmed reduced fuel ignition delay under highly boosted conditions relevant to modern downsized boosted SI engines, where in-cylinder pressure is higher and the temperature is cooler. Finally, at these conditions, charge reactivity increases compared to naturally aspirated conditions, and attenuation of knock by EGR is reduced.

33 ADVANCED PROPULSION SYSTEMS↗