Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Ultrathin GaN quantum disk nanowire LEDs with sub-250 nm electroluminescence

By quantum confining GaN at monolayer thickness with AlN barriers inside of a nanowire, deep ultraviolet LEDs are demonstrated. Full three-dimensional strain dependent energy band simulations are carried out within multiple quantum disk (MQD) GaN/AlN nanowire superlattice heterostructures. It is found that, even within the same nanowire MQD, the emission energy of the ultrathin GaN QDs varies from disk to disk due to the changing strain distribution and polarization charge induced energy band bending along the axial nanowire direction. MQD heterostructures are grown by plasma-assisted molecular beam epitaxy to form self-assembled catalyst-free nanowires with 1 to 2 monolayer thick GaN insertions within an AlN matrix. Photoluminescence peaks are observed at 295 nm and 283 nm from the 2 ML and 1 ML thick MQD samples, respectively. Polarization-doped nanowire LEDs are grown incorporating 1 ML thick GaN MQD active regions from which we observe deep ultraviolet electroluminescence. As a result, the shortest LED wavelength peak observed is 240 nm and attributed to electron hole recombination within 1 ML thick GaN QDs.

36 MATERIALS SCIENCE↗

Portable UV-visible spectrometer for measuring absorbance and dichroism of Langmuir monolayers at air-water interfaces.

An UV-visible spectrometer for measuring absorbance and dichroism of Langmuir monolayers under in situ conditions is described. The spectrometer utilizes a stand-alone multipass sensor, which is placed in a Langmuir trough and coupled with light source and spectrometer head via fiber optics. Implementation of the multipass scheme in the absorbance sensor makes it possible to obtain reliable quantitative spectroscopic data of the Langmuir monolayers with absorbance as low as 1 mOD. Such high sensitivity makes the developed sensor very useful for UV-visible spectral studies of a wide variety of chromophores. The new technique was applied to several model systems: fatty acid monolayers containing amphiphilic dyes DiI or BODIPY and also a monolayer of a synthetic amphiphilic porphyrin-binding peptide BBC16. Implementation of UV-visible absorbance spectroscopy measurements in situ together with x-ray scattering technique was used to confirm the bound state of the chromophore, and determine the exact position of the latter in the peptide matrix. Fiber optics design of the spectrometer provides portability and compatibility with other experimental techniques making it possible to study samples with a geometry unsuitable for conventional spectroscopic measurements and located in experimental environments with spatial limitations, such as synchrotron x-ray scattering stations.

36 MATERIALS SCIENCE↗

Emission Properties from ZnO Quantum Dots Dispersed in SiO{sub 2} Matrix

Dispersion of ZnO quantum dots in SiO{sub 2} matrix has been achieved in two techniques based on StOeber method to form ZnO QDs-SiO{sub 2} nanocomposites. Sample A is formed with random dispersion by adding tetraethyl orthosilicate (TEOS) to an ethanolic solution of ZnO nanoparticles and sample B is formed with a chain-like ordered dispersion by adding ZnO nanoparticles to an already hydrolyzed ethanolic TEOS solution. The photoluminescence spectra of the as-grown nanocomposites show strong emission in the ultraviolet region. When annealed at higher temperature, depending on the sample type, these show strong red or white emission. Interestingly, when the excitation is removed, the orderly dispersed ZnO QDs-SiO{sub 2} composite shows a very bright blue fluorescence visible by naked eyes for few seconds indicating their promise for display applications.

36 MATERIALS SCIENCE↗

Dynamics of tetrahydrofuran as minority component in a mixture with poly(2-(dimethylamino)ethyl methacrylate): A neutron scattering and dielectric spectroscopy investigation

We have investigated a mixture of poly(2-(dimethylamino)ethyl methacrylate) (PDMAEMA) and tetrahydrofuran (THF) (70 wt. % PDMAEMA/30 wt. % THF) by combining dielectric spectroscopy and quasielastic neutron scattering (QENS) on a labelled sample, focusing on the dynamics of the THF molecules. Two independent processes have been identified. The “fast” one has been qualified as due to an internal motion of the THF ring leading to hydrogen displacements of about 3 Å with rather broadly distributed activation energies. The “slow” process is characterized by an Arrhenius-like temperature dependence of the characteristic time which persists over more than 9 orders of magnitude in time. The QENS results evidence the confined nature of this process, determining a size of about 8 Å for the volume within which THF hydrogens’ motions are restricted. In a complementary way, we have also investigated the structural features of the sample. This study suggests that THF molecules are well dispersed among side-groups nano-domains in the polymer matrix, ruling out a significant presence of clusters of solvent. Such a good dispersion, together with a rich mobility of the local environment, would prevent cooperativity effects to develop for the structural relaxation of solvent molecules, frustrating thereby the emergence of Vogel-Fulcher-like behavior, at least in the whole temperature interval investigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ag induced electromagnetic interference shielding of Ag-graphite/PVDF flexible nanocomposites thinfilms

We report Ag nanoparticle induced Electromagnetic Interference (EMI) shielding in a flexible composite films of Ag nanoparticles incorporated graphite/poly-vinylidene difluoride (PVDF). PVDF nanocomposite thin-films were synthesized by intercalating Ag in Graphite (GIC) followed by dispersing GIC in PVDF. The X-ray diffraction analysis and the high-resolution transmission electron microscope clearly dictate the microstructure of silver nanoparticles in graphite intercalated composite of PVDF matrix. The conductivity values of nanocomposites are increased upto 2.5 times when compared to neat PVDF having a value of 2.70 S/cm at 1 MHz. The presence of Ag broadly enhanced the dielectric constant and lowers the dielectric loss of PVDF matrix proportional to Ag content. The EMI shielding effectiveness of the composites is 29.1 dB at 12.4 GHz for the sample having 5 wt. % Ag and 10 wt. % graphite in PVDF.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reexamining circular dichroism in photoemission from a topological insulator

The orbital angular momentum (OAM) of electron states is an essential ingredient for topological and quantum geometric quantities in solids. For example, Dirac surface states with helical spin- and orbital-angular momenta are a hallmark of a 3D topological insulator. Angle-resolved photoemission spectroscopy (ARPES) with variable circular light polarization, known as circular dichroism (CD), has been assumed to be a direct probe of OAM and, by proxy, of the Berry curvature of electronic bands in energy- and momentum-space. Indeed, topological surface states have been shown to exhibit angle-dependent CD (CDAD), and more broadly, CD is often interpreted as evidence of spin-orbit coupling. Meanwhile, it is well-established that CD originates from the photoemission matrix elements, which can have extrinsic contributions related to the experimental geometry and the inherently broken inversion symmetry at the sample surface. Therefore, it is important to broadly examine CD-ARPES to determine the scenarios in which it provides a robust probe of intrinsic material physics. We performed CD-ARPES on the canonical topological insulator Bi 2 ⁢Se 3 over a wide range of incident photon energies. Not only do we observe angle-dependent CD in the surface states, as expected, but we also find CD of a similar magnitude in virtually all bulk bands. Since OAM is forbidden by inversion symmetry in the bulk, we conclude this originates from symmetry-breaking in the photoemission process. Comparison with theoretical calculations supports this view and suggests that “hidden” OAM—localized to atomic sites within each unit cell—contributes significantly. Additional effects, including inter-atomic interference and final-state resonances, are responsible for the rapid variation of the CDAD signal with photon energy.

Sidilkover, Ittai [Tel Aviv University, Tel Aviv (↗

Inhomogeneous width of oxygen-deficient centers induced by electron irradiation of silica

We report a study of the luminescence activity of oxygen-deficient centers stabilized in as-grown synthetic silica, as compared with the same defects induced by {beta} irradiation at increasing doses, ranging from 1.2x10{sup 3} to 5x10{sup 6} kGy. We experimentally observe a progressive broadening of the luminescence band with increasing total electron dose released on samples. By analyzing our data within a theoretical model capable of separating homogeneous and inhomogeneous contribution to the total luminescence linewidth, we observe that the increasing of the width is entirely ascribable to the inhomogeneous component which increases, in the most irradiated sample, of 60% with respect to the value in the as-grown sample. This effect can be due either to the progressive creation of new defects statistically exploring different sites of the matrix, or to a progressive structural transformation of silica host which affects the optical properties of induced point defects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved precision in As speciation analysis with HERFD-XANES at the As K -edge: the case of As speciation in mine waste

High-energy-resolution fluorescence-detected (HERFD) X-ray absorption near-edge spectroscopy (XANES) is a spectroscopic method that allows for increased spectral feature resolution, and greater selectivity to decrease complex matrix effects compared with conventional XANES. XANES is an ideal tool for speciation of elements in solid-phase environmental samples. Accurate speciation of As in mine waste materials is important for understanding the mobility and toxicity of As in near-surface environments. In this study, linear combination fitting (LCF) was performed on synthetic spectra generated from mixtures of eight measured reference compounds for both HERFD-XANES and transmission-detected XANES to evaluate the improvement in quantitative speciation with HERFD-XANES spectra. The reference compounds arsenolite (As 2 O 3 ), orpiment (As 2 S 3 ), getchellite (AsSbS 3 ), arsenopyrite (FeAsS), kaňkite (FeAsO 4 ·3.5H 2 O), scorodite (FeAsO 4 ·2H 2 O), sodium arsenate (Na 3 AsO 4 ), and realgar (As 4 S 4 ) were selected for their importance in mine waste systems. Statistical methods of principal component analysis and target transformation were employed to determine whether HERFD improves identification of the components in a dataset of mixtures of reference compounds. LCF was performed on HERFD- and total fluorescence yield (TFY)-XANES spectra collected from mine waste samples. Arsenopyrite, arsenolite, orpiment, and sodium arsenate were more accurately identified in the synthetic HERFD-XANES spectra compared with the transmission-XANES spectra. In mine waste samples containing arsenopyrite and either scorodite or kaňkite, LCF with HERFD-XANES measurements resulted in fits with smaller R -factors than concurrently collected TFY measurements. The improved accuracy of HERFD-XANES analysis may provide enhanced delineation of As phases controlling biogeochemical reactions in mine wastes, contaminated soils, and remediation systems.

58 GEOSCIENCES↗

Low-Activity Waste Glass Standards Preparation and Characterization for Calibration of Analytical Instruments

A matrix of seven low-activity waste (LAW) glasses was fabricated and characterized to be used by the Hanford Waste Treatment and Immobilization Plant (WTP) as analytical instrument calibration and matrix interference standards when measuring LAW glass compositions. The matrix of glasses was designed to represent the range of LAW glass compositions that will be generated by the WTP. Samples from each of the seven glasses were measured with electron probe microanalysis (EPMA), ion chromatography (IC), and bulk inductively coupled plasma mass spectroscopy (ICP-MS) to determine the variability and accuracy across batches and within individually poured glass bar samples. High relative percent differences and standard deviations were calculated for components with low concentrations due to instrument detection limits. IC and ICP-MS percent differences and standard deviations were higher at low component concentrations. Otherwise, variability in measured compositions from IC and ICP-MS was generally lower than measurements from EPMA, with the exclusion of Cl, F, Si, and B. Overall, the two methods proved comparable and complementary. From EPMA, IC, and ICP-MS data, volatile elements were underrepresented compared to batched compositions, which suggested loss of these elements during melting. EPMA data was statistically analyzed to evaluate homogeneity within single bars and whole compositions for each of the seven glasses. Most of the variability within glass compositions occurred at the bar-to-bar level; however, no clear systematic trends were observed. Based on these analyses, when using these glasses as reference material, it is recommended that the overall mean and variance of each composition be used for performing instrument calibrations and analytical corrections.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Reduced-Order Model of Transport Phenomena for Power Plant Simulation

A reduced-order model based on proper orthogonal decomposition (POD) has been developed to simulate transient two- and three-dimensional isothermal and non-isothermal flows in a fluidized bed. Reduced-order models of void fraction, gas and solids temperatures, granular energy, and z-direction gas and solids velocity have been added to the previous version of the code. These algorithms are presented and their implementation is discussed. Verification studies are presented for each algorithm. A number of methods to accelerate the computations performed by the reduced-order model are presented. The errors associated with each acceleration method are computed and discussed. Using a combination of acceleration methods, a two-dimensional isothermal simulation using the reduced-order model is shown to be 114 times faster than using the full-order model. In the pursue of achieving the objectives of the project and completing the tasks planned for this program, several unplanned and unforeseen results, methods and studies have been generated. These additional accomplishments are also presented and they include: (1) a study of the effect of snapshot sampling time on the computation of the POD basis functions, (2) an investigation of different strategies for generating the autocorrelation matrix used to find the POD basis functions, (3) the development and implementation of a bubble detection and tracking algorithm based on mathematical morphology, (4) a method for augmenting the proper orthogonal decomposition to better capture flows with discontinuities, such as bubbles, and (5) a mixed reduced-order/full-order model, called point-mode proper orthogonal decomposition, designed to avoid unphysical due to approximation errors. The limitations of the proper orthogonal decomposition method in simulating transient flows with moving discontinuities, such as bubbling flows, are discussed and several methods are proposed to adapt the method for future use.

01 COAL, LIGNITE, AND PEAT↗

Utility of spatially-resolved atmospheric pressure surface sampling and ionization techniques as alternatives to mass spectrometric imaging (MSI) in drug metabolism

1. Tissue distribution studies of drug molecules play an essential role in the pharmaceutical industry and are commonly undertaken using quantitative whole body autoradiography (QWBA) methods. 2. The growing need for complementary methods to address some scientific gaps around radiography methods has led to increased use of mass spectrometric imaging (MSI) technology over the last 5 to 10 years. More recently, the development of novel mass spectrometric techniques for ambient surface sampling has redefined what can be regarded as fit-for-purpose for MSI in a drug metabolism and disposition arena. 3. Together with a review of these novel alternatives, this paper details the use of two liquid microjunction (LMJ)- based mass spectrometric surface sampling technologies. These approaches are used to provide qualitative determination of parent drug in rat liver tissue slices using liquid extraction surface analysis (LESA) and to assess the performance of a LMJ surface sampling probe (LMJ-SSP) interface for quantitative assessment of parent drug in brain, liver and muscle tissue slices. 4. An assessment of the utility of these spatially-resolved sampling methods is given, showing interdependence between mass spectrometric and QWBA methods, in particular there emerges a reason to question typical MSI workflows for drug metabolism; suggesting the expedient use of profile or region analysis may be more appropriate, rather than generating time-intensive molecular images of the entire tissue section.

ambient surface sampling↗

A Data-scientific Noise-removal Method for Efficient Submillimeter Spectroscopy With Single-dish Telescopes

For submillimeter spectroscopy with ground-based single-dish telescopes, removing the noise contribution from the Earth’s atmosphere and the instrument is essential. For this purpose, here we propose a new method based on a data-scientific approach. The key technique is statistical matrix decomposition that automatically separates the signals of astronomical emission lines from the drift noise components in the fast-sampled (1–10 Hz) time-series spectra obtained by a position-switching (PSW) observation. Because the proposed method does not apply subtraction between two sets of noisy data (i.e., on-source and off-source spectra), it improves the observation sensitivity by a factor of √2. It also reduces artificial signals such as baseline ripples on a spectrum, which may also help to improve the effective sensitivity. We demonstrate this improvement by using the spectroscopic data of emission lines toward a high-redshift galaxy observed with a 2 mm receiver on the 50 m Large Millimeter Telescope. Since the proposed method is carried out offline and no additional measurements are required, it offers an instant improvement on the spectra reduced so far with the conventional method. It also enables efficient deep spectroscopy driven by the future 50 m class large submillimeter single-dish telescopes, where fast PSW observations by mechanical antenna or mirror drive are difficult to achieve.

47 OTHER INSTRUMENTATION↗

Reexamining Circular Dichroism in Photoemission From a Topological Insulator

The orbital angular momentum (OAM) of electron states is an essential ingredient for topological and quantum geometric quantities in solids. For example, Dirac surface states with helical spin- and orbital-angular momenta are a hallmark of a 3D topological insulator. Angle-resolved photoemission spectroscopy (ARPES) with variable circular light polarization, known as circular dichroism (CD), has been assumed to be a direct probe of OAM and, by proxy, of the Berry curvature of electronic bands in energy- and momentum-space. Indeed, topological surface states have been shown to exhibit angle-dependent CD (CDAD), and more broadly, CD is often interpreted as evidence of spin-orbit coupling. Meanwhile, it is well-established that CD originates from the photoemission matrix elements, which can have extrinsic contributions related to the experimental geometry and the inherently broken inversion symmetry at the sample surface. Therefore, it is important to broadly examine CD-ARPES to determine the scenarios in which it provides a robust probe of intrinsic material physics. We performed CD-ARPES on the canonical topological insulator $\mathrm{Bi}_2\mathrm{Se}_3$ over a wide range of incident photon energies. Not only do we observe angle-dependent CD in the surface states, as expected, but we also find CD of a similar magnitude in virtually all bulk bands. Since OAM is forbidden by inversion symmetry in the bulk, we conclude this originates from symmetry-breaking in the photoemission process. Comparison with theoretical calculations supports this view and suggests that $\textit{hidden}$ OAM - localized to atomic sites within each unit cell - contributes significantly. Additional effects, including inter-atomic interference and final-state resonances, are responsible for the rapid variation of the CDAD signal with photon energy.

FOS: Physical sciences↗

Corrosion of metal samples rapidly measured

Corrosion of a large number of metal samples that have been exposed to controlled environment is accurately and rapidly measured. Wire samples of the metal are embedded in clear plastic and sectioned for microexamination. Unexposed wire can be included in the matrix as a reference.

Maskell, C. E.↗

Silver-Teflon contamination UV radiation study

Silver-Teflon (Ag/FEP) is planned to be used as the thermal control material covering the radiator surfaces on the shuttle orbiter payload bay doors. These radiators require the use of materials that have a very low solar absorptance and a high emittance for heat rejection. However, operationally, materials used on these critical radiator surfaces, such as silver-Teflon, will be exposed to a variety of conditions which include both the natural as well as the induced environments from the Shuttle Orbiter. A complete test facility was assembled, and detailed test procedures and a test matrix were developed. Measurements of low solar absorptance were taken before and after contamination, at intervals during irradiation, and after sample cleaning to fulfill all the requirements.

Muscari, J. A.↗

Nonlinear filtering for spacecraft attitude estimation

Nonlinear filtering techniques are applied to spacecraft attitude estimation using quaternion parameterization for the attitude kinematics. By replacing the angular velocity vector by the gyro output vector, a state dependent noise vector is introduced in the seven-dimensional system equations. The resulting conditional probability density function from the Ito differential rule is governed by the Fokker Planck partial differential equation which is approximated by the second order mean and covariance differential equations. In order to minimize computer loading, the covariance propagation is carried out in six-dimensional state space using a matrix transformation. The star tracker data is used to update the covariance matrix in the seven-dimensional space. The algorithm is simulated for an earth pointing spacecraft mission, using Monte Carlo samples of gyro and star measurements. The performance of the second order filter is compared with the extended Kalman Filter through several simulation runs and drift rates have been identified.

Vathsal, S.↗

Investigation of interfacial shear strength in a SiC fibre/Ti-24Al-11Nb composite by a fibre push-out technique

A fiber push-out technique applied at several sample thicknesses was used to determine both the debond shear stress and the frictional shear stress at the fiber-matrix interface at room temperautre for a unidirectional SiC fiber-reinforced T-24Al-11Nb (in at. pct) composite prepared by a powder cloth technique. The push-out technique measures the separate contributions of bond strength and friction to the mechanical shear strength at the fiber-matrix interface. It was found that the fiber-matrix bond shear strength of this material is significantly higher than the fiber-matrix frictional shear stress (119.2 and 47.8 MPa, respectively).

Eldridge, J. I.↗

Influence of Specimen Preparation and Specimen Size on Composite Transverse Tensile Strength and Scatter

The influence of specimen polishing, configuration, and size on the transverse tension strength of two glass-epoxy materials, and one carbon-epoxy material, loaded in three and four point bending was evaluated. Polishing machined edges, arid/or tension side failure surfaces, was detrimental to specimen strength characterization instead of yielding a higher, more accurate, strength as a result of removing inherent manufacture and handling flaws. Transverse tension strength was typically lower for longer span lengths due to the classical weakest link effect. However, strength was less sensitive to volume changes achieved by increasing specimen width. The Weibull scaling law typically over-predicted changes in transverse tension strengths in three point bend tests and under-predicted changes in transverse tension strengths in four point bend tests. Furthermore, the Weibull slope varied with specimen configuration, volume, and sample size. Hence, this scaling law was not adequate for predicting transverse tension strength of heterogeneous, fiber-reinforced, polymer matrix composites.

OBrien, T. Kevin↗