Search NASA⌕ Search

SEARCH · Search NASA

Results for “power system optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Optimisation of dynamic reactive power sources using mesh adaptive direct search

Dynamic reactive power sources can be used to effectively mitigate the fault-induced delayed voltage recovery and transient voltage instability issues. When many var sources need to be installed at planned locations, optimisation of their sizes is a complicated non-linear optimisation problem due to its non-convexity and the dependence of the constraint on time-series trajectories of post-fault voltages. Solving this optimal sizing problem needs to utilise both a non-linear optimisation solver and a power system differential-algebraic equation solver. This study proposes a new approach for solving this problem under both a single contingency and multiple contingencies by using the mesh adaptive direct search algorithm interfaced with a power system simulator. The proposed approach is validated by case studies on a North American Eastern Interconnection model to optimise the sizes of planned STATCOMs against critical contingencies.

Huang, Weihong↗

Actuator Grouping Optimization on Flexible Space Reflectors

With the rapid advances in deployable membrane and mesh antenna technologies, the feasibility of developing large, lightweight reflectors has greatly improved. In order to achieve the required surface accuracy, precision surface control is needed on these lightweight reflectors. For this study, an analytical model is shown which combines a flexible Kapton reflector with Polyvinylidene fluoride (PVDF) actuators for surface control. Surface errors are introduced that are similar to real world scenarios, and a least squares control algorithm is developed for surface control. Experimental results on a 2.4 meter reflector show that while the analytical reflector model is generally correct, due to idiosyncrasies in the reflector it cannot be used for online control. A new method called the En Mass Elimination algorithm is used to determine the optimal grouping of actuators when the number of actuators in the system exceeds the number of power supplies available.

en masse elimination (EME) algorithm↗

Monitoring/Verification Using DMS: TATP Example

Field-rugged and field-programmable differential mobility spectrometry (DMS) networks provide highly selective, universal monitoring of vapors and aerosols at detectable levels from persons or areas involved with illicit chemical/biological/explosives (CBE) production. CBE sensor motes used in conjunction with automated fast gas chromatography with DMS detection (GC/DMS) verification instrumentation integrated into situational operationsmanagement systems can be readily deployed and optimized for changing application scenarios. The feasibility of developing selective DMS motes for a “smart dust” sampling approach with guided, highly selective, fast GC/DMS verification analysis is a compelling approach to minimize or prevent the illegal use of explosives or chemical and biological materials. DMS is currently one of the foremost emerging technologies for field separation and detection of gas-phase chemical species. This is due to trace-level detection limits, high selectivity, and small size. GC is the leading analytical method for the separation of chemical species in complex mixtures. Low-thermal-mass GC columns have led to compact, low-power field systems capable of complete analyses in 15–300 seconds. A collaborative effort optimized a handheld, fast GC/DMS, equipped with a non-rad ionization source, for peroxide-based explosive measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Component-Sizing Methodology for a Hybrid Electric Vehicle Using an Optimization Algorithm

Many leading companies in the automotive industry have been putting tremendous effort into developing new powertrains and technologies to make their products more energy efficient. Evaluating the fuel economy benefit of a new technology in specific powertrain systems is straightforward; and, in an early concept phase, obtaining a projection of energy efficiency benefits from new technologies is extremely useful. However, when carmakers consider new technology or powertrain configurations, they must deal with a trade-off problem involving factors such as energy efficiency and performance, because of the complexities of sizing a vehicle’s powertrain components, which directly affect its energy efficiency and dynamic performance. As powertrains of modern vehicles become more complicated, even more effort is required to design the size of each component. This study presents a component-sizing process based on the forward-looking vehicle simulator “Autonomie” and the optimization algorithm “POUNDERS”; the supervisory control strategy based on Pontryagin’s Minimum Principle (PMP) assures sufficient computational system efficiency. We tested the process by applying it to a single power-split hybrid electric vehicle to determine optimal values of gear ratios and each component size, where we defined the optimization problem as minimizing energy consumption when the vehicle’s dynamic performance is given as a performance constraint. The suggested sizing process will be helpful in determining optimal component sizes for vehicle powertrain to maximize fuel efficiency while dynamic performance is satisfied. Indeed, this process does not require the engineer’s intuition or rules based on heuristics required in the rule-based process.

33 ADVANCED PROPULSION SYSTEMS↗

Robust Control of Uncertain Systems via Dissipative LQG-Type Controllers

Optimal controller design is addressed for a class of linear, time-invariant systems which are dissipative with respect to a quadratic power function. The system matrices are assumed to be affine functions of uncertain parameters confined to a convex polytopic region in the parameter space. For such systems, a method is developed for designing a controller which is dissipative with respect to a given power function, and is simultaneously optimal in the linear-quadratic-Gaussian (LQG) sense. The resulting controller provides robust stability as well as optimal performance. Three important special cases, namely, passive, norm-bounded, and sector-bounded controllers, which are also LQG-optimal, are presented. The results give new methods for robust controller design in the presence of parametric uncertainties.

Joshi, Suresh M.↗

Control Strategies for Distributed Energy Resources to Maximize the Use of Wind Power in Rural Microgrids

The focus of this paper is to design control strategies for distributed energy resources (DERs) to maximize the use of wind power in a rural microgrid. In such a system, it may be economical to harness wind power to reduce the consumption of fossil fuels for electricity production. In this work, we develop control strategies for DERs, including diesel generators, energy storage and demand response, to achieve high penetration of wind energy in a rural microgrid. Combinations of centralized (direct control) and decentralized (autonomous response) control strategies are investigated. Detailed dynamic models for a rural microgrid are built to conduct simulations. The system response to large disturbances and frequency regulation are tested. It is shown that optimal control coordination of DERs can be achieved to maintain system frequency while maximizing wind power usage and reducing the wear and tear on fossil fueled generators.

17 WIND ENERGY↗

Investigations on optimization of accident management measures following a station blackout accident in a VVER-1000 pressurized water reactor

The reactor safety issues are of primary importance for preserving the health of the population and ensuring no release of radioactivity and fission products into the environment. A part of the nuclear research focuses on improvement of the safety of existing nuclear power plants. Studies, research and efforts are a continuing process at improving the safety and reliability of existing and newly developed nuclear power plants at prevention of a core melt accident. Station blackout (loss of AC power supply) is one of the dominant accidents taken into consideration at performing accident analysis. In case of multiple failures of safety systems it leads to a severe accident. To prevent an accident to turn into a severe one or to mitigate the consequences, accident management measures must be performed. The present paper outlines possibilities for application and optimization of accident management measures following a station blackout accident. Assessed is the behaviour of the nuclear power plant during a station blackout accident without accident management measures and with application of primary/secondary side oriented accident management measures. Discussed are the possibilities for operators ' intervention and the influence of the performed accident management measures on the course of the accident. Special attention has been paid to the effectiveness of the passive feeding and physical phenomena having an influence on the system behaviour. The performed simulations show that the effectiveness of the secondary side feeding procedure can be limited due to an early evaporation or flashing effects in the feed water system. The analyzed cases show that the effectiveness of the accident management measures strongly depends on the initiation criteria applied for depressurization of the reactor coolant system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Convex Optimization of Integrated Power-Gas Energy Flow Model With Applications to Probabilistic Energy Flow

Energy flow calculation is a fundamental problem of the integrated power and gas system (IPGS) operation and planning. However, the nonlinear gas flow model introduces major challenges to the energy flow calculation. In this paper, we propose a tractably convex optimization model to solve the energy flow problem in IPGSs. It is demonstrated that the proposed optimization model has the same optimal solution as the original nonlinear steady energy flow model. Also, piecewise linearization is adopted to tightly linearize the nonlinear objective function of the model, which transforms the formulated convex optimization into a linear program one. Thus, the computation complexity of the proposed energy flow model is significantly reduced as compared with the existing methods. In addition, the proposed model can be extended to probabilistic energy flow estimation. Extensive case studies are conducted to validate the effectiveness of the proposed energy flow model using three IPGSs.

42 ENGINEERING↗

Monitoring/Verification using DMS: TATP Example

Field-rugged and field-programmable differential mobility spectrometry (DMS) networks provide highly selective, universal monitoring of vapors and aerosols at detectable levels from persons or areas involved with illicit chemical/biological/explosives (CBE) production. CBE sensor motes used in conjunction with automated fast gas chromatography with DMS detection (GC/DMS) verification instrumentation integrated into situational operations-management systems can be readily deployed and optimized for changing application scenarios. The feasibility of developing selective DMS motes for a “smart dust” sampling approach with guided, highly selective, fast GC/DMS verification analysis is a compelling approach to minimize or prevent the illegal use of explosives or chemical and biological materials. DMS is currently one of the foremost emerging technologies for field separation and detection of gas-phase chemical species. This is due to trace-level detection limits, high selectivity, and small size. Fast GC is the leading field analytical method for gas phase separation of chemical species in complex mixtures. Low-thermal-mass GC columns have led to compact, low-power field systems capable of complete analyses in 15–300 seconds. A collaborative effort optimized a handheld, fast GC/DMS, equipped with a non-rad ionization source, for peroxide-based explosive measurements.

47 OTHER INSTRUMENTATION↗

Air Cooling for High Temperature Power Electronics (Presentation)

Current emphasis on developing high-temperature power electronics, including wide-bandgap materials such as silicon carbide and gallium nitride, increases the opportunity for a completely air-cooled inverter at higher powers. This removes the liquid cooling system for the inverter, saving weight and volume on the liquid-to-air heat exchanger, coolant lines, pumps, and coolant, replacing them with just a fan and air supply ducting. We investigate the potential for an air-cooled heat exchanger from a component and systems-level approach to meet specific power and power density targets. A proposed baseline air-cooled heat exchanger design that does not meet those targets was optimized using a parametric computational fluid dynamics analysis, examining the effects of heat exchanger geometry and device location, fixing the device heat dissipation and maximum junction temperature. The CFD results were extrapolated to a full inverter, including casing, capacitor, bus bar, gate driver, and control board component weights and volumes. Surrogate ducting was tested to understand the pressure drop and subsequent system parasitic load. Geometries that met targets with acceptable loads on the system were down-selected for experimentation. Nine baseline configuration modules dissipated the target heat dissipation, but fell below specific power and power density targets. Six optimized configuration modules dissipated the target heat load, exceeding the specific power and power density targets. By maintaining the same 175 degrees C maximum junction temperature, an optimized heat exchanger design and higher device heat fluxes allowed a reduction in the number of modules required, increasing specific power and power density while still maintaining the inverter power.

30 DIRECT ENERGY CONVERSION↗

A comparison of Ultra-Sensitive Coherent Detection (USCD) and heterodyne detection for a wind sensing application

Ultra-Sensitive Coherent Detection (USCT) and conventional heterodyne detection methods were evaluated for use as a space-borne wind sensing system. For this study, we assume that the wind sensing system would be available by the year 2015. Consequently, laser systems and detectors more advanced than those under consideration for near term programs could be included. Three laser candidates under evaluation are Nd-YAG at 1.06 microns, Ho-YAG at 2.1 microns, and CO2 at 9.11 microns. Both heterodyne and USCD detection methods were included. The primary stress is on the optimization of weight and power consumption of the wind sensor portion of the satellite system.

Amimoto, Sherwin↗

Making the Grid "Smart" Through "Smart" Microgrids: Real-Time Power Management of Microgrids with Multiple Distributed Generation Sources Using Intelligent Control

In this Project we collaborated with two DOE National Laboratories, Pacific Northwest National Lab (PNNL) and Lawrence Berkeley National Lab (LBL). Dr. Hammerstrom of PNNL initially supported our project and was on the graduate committee of one of the Ph.D. students (graduated in 2014) who was supported by this project. He is also a committee member of a current graduate student of the PI who was supported by this project in the last two years (August 2014-July 2016). The graduate student is now supported be the Electrical and Computer Engineering (ECE) Department at Montana State University (MSU). Dr. Chris Marney of LBL provided actual load data, and the software WEBOPT developed at LBL for microgrid (MG) design for our project. NEC-Labs America, a private industry, also supported our project, providing expert support and modest financial support. We also used the software “HOMER,” originally developed at the National Renewable Energy Laboratory (NREL) and the most recent version made available to us by HOMER Energy, Inc., for MG (hybrid energy system) unit sizing. We compared the findings from WebOpt and HOMER and designed appropriately sized hybrid systems for our case studies. The objective of the project was to investigate real-time power management strategies for MGs using intelligent control, considering maximum feasible energy sustainability, reliability and efficiency while, minimizing cost and undesired environmental impact (emissions). Through analytic and simulation studies, we evaluated the suitability of several heuristic and artificial-intelligence (AI)-based optimization techniques that had potential for real-time MG power management, including genetic algorithms (GA), ant colony optimization (ACO), particle swarm optimization (PSO), and multi-agent systems (MAS), which is based on the negotiation of smart software-based agents. We found that PSO and MAS, in particular, distributed MAS, were more efficient and better suited for our work. We investigated the following: • Intelligent load control - demand response (DR) - for frequency stabilization in islanded MGs (partially supported by PNNL). • The impact of high penetration of solar photovoltaic (PV)-generated power at the distribution level (partially supported by PNNL). • The application of AI approaches to renewable (wind, PV) power forecasting (proposed by the reviewers of our proposal). • Application of AI approaches and DR for real-time MG power management (partially supported by NEC Labs-America) • Application of DR in dealing with the variability of wind power • Real-time MG power management using DR and storage (partially supported by NEC Labs-America) • Application of DR in enhancing the performance of load-frequency controller • MAS-based whole-sale and retail power market design for smart grid A

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interplanetary Trajectory Optimization with Powerlimited Propulsion Systems

A trajectory-optimization process is described in which the optimum­ thrust equations are derived using the calculus of variations. The mag­nitude of the thrust is constrained within an upper and a lower bound, but the thrust direction is arbitrary. This formulation allows both the constant-thrust program and the variable-thrust program to be con­sidered. For the constant-thrust program, certain propulsion-system parameters are optimized for maximum final vehicle mass. This theory has been used to study interplanetary missions to Venus and Mars using a power-limited propulsion system. Both one-way and round­ trip rendezvous trajectories are considered. The analysis employs a two-body inverse-square force-field model of three dimensions. An iterative routine used to solve the two-point boundary-value problem is described in the Appendix.

TRAJECTORY↗

Managing code transformations for better performance portability

Code optimization is an intricate task that is getting more complex as computing systems evolve. Managing the program optimization process, including the implementation and evaluation of code variants, is tedious, inefficient, and errors are likely to be introduced in the process. Moreover, because each platform typically requires a different sequence of transformations to fully harness its computing power, the optimization process complexity grows as new platforms are adopted. To address these issues, systems and frameworks have been proposed to automate the code optimization process. They, however, have not been widely adopted and are primarily used by experts with deep knowledge about underlying architecture and compiler intricacies. This article describes the requirements that we believe necessary for making automatic performance tuning more broadly used, especially in complex, long-lived high-performance computing applications. Besides discussing limitations of current systems and strategies to overcome these, we describe the design of a system that is able to semi-automatically generate efficient platform-specific code. In the proposed system, the code optimization is programmer-guided, separately from application code, on an external file in what we call optimization programming. The language to program the optimization process is able to represent complex collections of transformations and, as a result, generate efficient platform-specific code. A database manages different optimized versions of code regions, providing a pragmatic approach to performance portability, and the framework itself has separate components, allowing the optimized code to be used on systems without installing all of the modules required for the code generation. We present experiments on two different platforms to illustrate the generation of efficient platform-specific code that performs comparable to hand-optimized, vendor-provided code.

Computer Science↗

Protecting and Defending against Autonomous Control Systems and Digital Twin Cyber Attacks: Response Strategy for Hyperparameter attacks of Digital Twin Machine Learning Models in Nuclear Power Plants (Final)

Navigating through the complex tapestry of technological advancements, "Response Strategy for Hyperparameter attacks of Digital Twin Machine Learning Model in Nuclear Power Plants" stands at the intersection of cybersecurity and nuclear power plant operations, embarking on a journey through the intricacies of securing digital twins against malicious cyber activities. As nuclear power plants progressively integrate digital twin technology and machine learning models to optimize operations and ensure system reliability, they inadvertently expose themselves to a new spectrum of vulnerabilities, notably in the realm of hyperparameter attacks. Hyperparameters, integral in machine learning model tuning and optimal performance of digital twins, have emerged as a target for adversaries aiming to destabilize the predictive capabilities and therefore, the operational accuracy of these digital entities within critical infrastructures like nuclear plants. This paper, therefore, meticulously threads the needle through the development of a robust response strategy, poised to shield these digital reflections against calculated hyperparameter manipulations, ensuring that the digital twin can effectively and securely function as a reliable proxy for its physical counterpart. The ensuing sections delve into the orchestrated maelstrom of multi-rate time-changing intelligent coordinated hyperparameter attacks and the implementation of event-triggered predictive control, laying down a structured, predictive, and responsive framework that safeguards the nexus where the digital and physical realms of nuclear power plants coalesce. The operational integrity of digital twins in nuclear power plants depends critically on the security of machine learning hyperparameters. This study makes two different contributions. First, a decision-based idea known as a multi-rate time changing intelligent coordinated hyperparameter attack is put forth. In this attack, many hyperparameters are repeatedly changed using both random and intelligent optimal techniques by the attacker. These assaults introduce varied rates at different attack steps, compromise various amounts of hyperparameters, and improve stealth and flexibility. Second, a technique is developed for event triggered predictive control to rapidly respond to potential hyperparameter attacks. This control integrates a sliding window framework, retaining a history of previous data points and employing linear regression to predict the next data point from the current dataset. The control gain K is determined using the Lyapunov-Krasovskii method, and subsequently, an action is developed. Finally, the outcome of the simulation demonstrates the viability of the proposed method for defending nuclear power plant digital twins from hyperparameter attacks.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimal operational controls for power grid

Power grid operation is facing increased penetration of renewables and distributed energy resources at both transmission and distribution levels. This presents an increased level of randomness and uncertainty for its operational quality, where the challenges are mainly how controls and optimizations can be performed so that the operational quality of the power grid can be maintained. An interesting feature is also that we need to make a good use of uncertainties embedded in the swing equation from the renewable contributions rather than simply trying to minimize the impact of uncertainties. Furthermore, this requires effective solutions on system estimation, control, and optimization. Indeed, in past decades, work has been carried out on the development of advanced controls and optimization for such complicated dynamic systems. Examples are optimal operational control for both performance and stability enhancement considering random renewables penetration, frequency, and active power control for microgrids and parameter estimation for various parts of the power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Electronics Manufacturing Improvements for Heavy-Duty Fuel Cell Vehicles

The Marel Power Solutions project, funded by the U.S. Department of Energy under Award DE-SC0023801, focused on advancing manufacturing techniques for power electronics in heavy-duty fuel cell vehicles. The research aimed to enhance system efficiency, reduce costs, and support broader adoption of hydrogen fuel cell technology. Key areas of investigation included power topology, thermal modeling, system architecture, and accessibility through software tools. Key Accomplishments: 1. Power Topology: - Developed an interleaved boost converter with optimized phase count, leveraging Marel’s proprietary Power Stacks. - Achieved reduced parasitic inductance and resistance, enabling high efficiency in DC-DC converters. 2. Thermal Modeling: - Integrated innovative cooling systems into compact Silicon Carbide (SiC) modules. - Simulations demonstrated the ability to dissipate significant heat (up to 7.5 kW), ensuring device reliability under heavy loads. 3. System Architecture: - Utilized simulation tools to analyze the impact of various fuel cell and vehicle parameters on efficiency. - Highlighted the role of smaller, modular improvements, such as enhanced DC-DC converters, in achieving system-wide gains. 4. Accessibility: - Evaluated and implemented MATLAB/Simulink code generation tools for real-world hardware applications. - Demonstrated the potential for rapid prototyping of custom power systems with reduced development costs. Impact and Benefits: - Efficiency and Cost Reduction: Marel’s cooling technology enhances SiC die performance, reducing the number of dies required and overall system size. - Scalability and Flexibility: The innovations support tailored solutions for diverse applications, from mass transit to mining vehicles. - Sustainability: The research promotes the integration of electrification technologies, helping meet rising energy demands sustainably. Conclusion: The project’s outcomes advance the state of power electronics for hydrogen fuel cell vehicles, enabling more efficient, compact, and cost-effective solutions. These developments lay a foundation for future innovation, contributing to the broader adoption of clean energy technologies in transportation and other industries.

08 HYDROGEN↗

Medium-Duty Delivery Truck Integrated Bidirectional Wireless Power Transfer System With Grid and Stationary Energy Storage System Connectivity

Electric vehicles (EVs) can provide power to the grid or buildings similar to distributed energy resources (DER) for energy balancing applications or optimizing the operation of the microgrids in harmony with the other DER assets. This article presents the operating modes of a bidirectional wireless power transfer (WPT) system designed for a medium-duty package delivery vehicle. The WPT system designed for this study can transfer 20 kW of power across 11 in of air gap using custom-designed double-D (DD) couplers with LCC–LCC tuning networks. The proposed system utilizes a 480-V three-phase grid connection, a plug-in hybrid delivery truck with bidirectional WPT, and a stationary energy storage system (SESS) that can be connected to the primary-side dc link. Due to the differences in primary and secondary dc bus voltages, and considering the voltage of the SESS, asymmetric voltage gains were used in the system. Sensitivity analyses of this system with respect to these voltage levels are presented. Five different operating modes of the grid, SESS, and the EV battery are investigated with experimental results. Control algorithms are described for grid-to-vehicle (G2V) and vehicle-to-grid (V2G) operating modes. A bidirectional WPT system is operated with a power factor of 0.99 on the grid side in every operating mode. The EV battery was charged with 20.3 kW with an overall efficiency of 93.02% in the G2V operating mode. Finally, in the V2G operating mode, the WPT system provided 12.82 kW of power back to the grid with an overall efficiency of 89.08%.

25 ENERGY STORAGE↗