Search NASA⌕ Search

SEARCH · Search NASA

Results for “quality monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Version 8 of the SMAP Level-4 Soil Moisture Data Assimilation Product

The NASA Soil Moisture Active Passive (SMAP) mission Level-4 Soil Moisture (L4_SM) product provides global, 9-km resolution, 3-hourly surface (0-5 cm) and root-zone (0-100 cm) soil moisture from April 2015 to present with a mean latency of 2.5 days from the time of observation. The product is based on the assimilation of SMAP L-band (1.4 GHz) brightness temperature (Tb) observations into the NASA Catchment land surface model as the model is driven with observations-based precipitation forcing. This presentation discusses the improvements in the forthcoming Version 8 of L4_SM, including updates in the precipitation forcing, the Catchment model parameters, and the L-band microwave radiative transfer model (mwRTM). The precipitation observations used in L4_SM Version 8 outside of North America and the high latitudes are from the latest (Version 7) NASA Integrated Multi-satellitE Retrievals for the Global Precipitation Measurement mission (IMERG) products. Moreover, occasionally excessive precipitation rates in earlier versions of L4_SM along certain longitudes in North America were eliminated by a bug fix in the precipitation corrections algorithm. The Catchment model in L4_SM Version 8 uses climatological snow albedo values based on observations from the Moderate Resolution Imaging Spectroradiometer, replacing the look-up table parameterization of earlier versions. Additionally, corrected soil parameters were implemented for a small region in Argentina that had erroneously been classified as peat because of an error in the ancillary soil data. Finally, the mwRTM in L4_SM Version 8 uses the Mironov soil mixing approach and updated values of the L-band scattering albedo, soil roughness, and vegetation opacity climatology obtained from the latest (Release 19) SMAP Level-2 dual-channel soil moisture retrieval product. During the development of L4_SM Version 8, the change in the mwRTM parameterization resulted in a reduced unbiased RMSE of surface soil moisture when verified against in situ measurements. It also reduced the standard deviation of the Tb observation-minus-forecast residuals by ~0.15 K, highlighting the importance of the mwRTM for successful data assimilation. The bug fixes in the precipitation corrections algorithm and the Catchment model soil parameters in the Argentina region result in locally large improvements of the simulated land surface states. In summary, the ongoing refinements of the L4_SM product continue to improve its science quality and performance for global soil moisture monitoring

Rolf Reichle↗

An independent algorithm to check the monitor units calculation in radiosurgery

Double checking of the monitor units (MU) is an important step in the quality assurance (QA) process in radiosurgery. In this paper we propose the use of an independent algorithm constructed using the ellipsoid which best fits the measurements taken with the bubble head frame. The monitor units calculated by this independent algorithm and the commercial planning system were compared in 40 patients treated with radiosurgery (57 isocenters, 320 arcs). The average relative difference was -0.2%{+-}2.1 (k=1). These results are better for the variance, -0.4%{+-}1.8 (k=1), when all the depths of the bubble head frame are measured and no arcs are calculated by extrapolation or when only one of these factors appear. If there are missing values in the bubble head frame measurements and the model is extrapolated, the variance of the results is greater, 0.4%{+-}3.9 (k=1). The algorithm is reliable as a QA tool for linac radiosurgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Summary: SEE4GEO

The seismoelectric effects technique (SEE) is a new and innovative approach for geothermal subsurface imaging and monitoring at reservoir scale. The objective of this project is to assess SEE in terms of data acquisition, cost and quality, and to determine its capability in comparison with classical imaging and monitoring techniques, particularly decoupled seismic and electromagnetic methods. This will be achieved by (1) development of a fast, true 3D numerical package, handling SEE imaging and subsurface properties characterization, including resistivity and permeability, (2) laboratory experiments performed in a controlled environment to define optimal deployment design, data quality, and inform field deployment, and (3) field surveys to ultimately test and draw lessons for practical use of SEE technology. There is a relatively extensive body of work in the literature on SEE, and members of this consortium have been involved in theoretical and numerical development of SEE modeling as well as laboratory experiments. Nevertheless, to our knowledge few, if any, documented efforts have been specifically targeting the use of SEE for geothermal subsurface imaging and monitoring. The strength and originality of our proposal rely on an integrated approach leveraging numerical, laboratory and field experiments, to properly document the practical use of SEE. Through this process, SEE in-hand technology for the geothermal industry will be able to progress from a TRL 1 to TRL 3.

58 GEOSCIENCES↗

Seismoelectric Effects for Geothermal Resources Assessment and Monitoring (SEE4GEO)

The seismoelectric effects technique (SEE) is a new and innovative approach for geothermal subsurface imaging and monitoring at reservoir scale. The objective of this project is to assess SEE in terms of data acquisition, cost and quality, and to determine its capability in comparison with classical imaging and monitoring techniques, particularly decoupled seismic and electromagnetic methods. This will be achieved by (1) development of a fast, true 3D numerical package, handling SEE imaging and subsurface properties characterization, including resistivity and permeability, (2) laboratory experiments performed in a controlled environment to define optimal deployment design, data quality, and inform field deployment, and (3) field surveys to ultimately test and draw lessons for practical use of SEE technology. There is a relatively extensive body of work in the literature on SEE, and members of this consortium have been involved in theoretical and numerical development of SEE modeling as well as laboratory experiments. Nevertheless, to our knowledge few, if any, documented efforts have been specifically targeting the use of SEE for geothermal subsurface imaging and monitoring. The strength and originality of our proposal rely on an integrated approach leveraging numerical, laboratory and field experiments, to properly document the practical use of SEE. Through this process, SEE in-hand technology for the geothermal industry will be able to progress from a TRL 1 to TRL 3.

58 GEOSCIENCES↗

Leveraging artificial intelligence and advanced food processing techniques for enhanced food safety, quality, and security: a comprehensive review

Artificial intelligence is emerging as a transformative force in addressing the multifaceted challenges of food safety, food quality, and food security. This review synthesizes advancements in AI-driven technologies, such as machine learning, deep learning, natural language processing, and computer vision, and their applications across the food supply chain, based on a comprehensive analysis of literature published from 1990 to 2024. AI enhances food safety through real-time contamination detection, predictive risk modeling, and compliance monitoring, reducing public health risks. It improves food quality by automating defect detection, optimizing shelf-life predictions, and ensuring consistency in taste, texture, and appearance. Furthermore, AI addresses food security by enabling resource-efficient agriculture, yield forecasting, and supply chain optimization to ensure the availability and accessibility of nutritious food resources. This review also highlights the integration of AI with advanced food processing techniques such as high-pressure processing, ultraviolet treatment, pulsed electric fields, cold plasma, and irradiation, which ensure microbial safety, extend shelf life, and enhance product quality. Additionally, the integration of AI with emerging technologies such as the Internet of Things, blockchain, and AI-powered sensors enables proactive risk management, predictive analytics, and automated quality control. By examining these innovations' potential to enhance transparency, efficiency, and decision-making within food systems, this review identifies current research gaps and proposes strategies to address barriers such as data limitations, model generalizability, and ethical concerns. These insights underscore the critical role of AI in advancing safer, higher-quality, and more secure food systems, guiding future research and fostering sustainable food systems that benefit public health and consumer trust.

AI↗

LYNM PE1 Shot A Meteorology Team Technical Report

Weather support for Shot A was done by NOAA’s Air Resources Laboratory (ARL) / Special Operations and Research Division (SORD) and Lawrence Livermore National Laboratory (LLNL). Weather support activities included wind and precipitation forecasting, maintaining and monitoring PE1 meteorology towers MT02-11, maintaining and monitoring the ARL/SORD tower on Aqueduct Mesa (A12AI, also called MT01), maintaining and monitoring the Blackbrush energy flux tower, radiosonde preparation and launch, providing weather conditions on shot day for go/no-go criteria, and quality control and submission of the datasets. ARL/SORD additionally maintains and monitors the meteorological tower network (Mesonet) and sodar (at Desert Rock) for NNSS.

54 ENVIRONMENTAL SCIENCES↗

Groundwater Level Status Report for Fiscal Year 2007 - Los Alamos National Laboratory

The status of groundwater level monitoring at Los Alamos National Laboratory in Fiscal Year 2007 is provided in this report. The Groundwater Level Monitoring Project was instituted in 2005 to provide a framework for the collection and processing of quality controlled groundwater level data. This report summarizes groundwater level data for 166 monitoring wells, including 45 regional aquifer wells, 25 intermediate wells, and 96 alluvial wells, and 11 water supply wells. Pressure transducers were installed in 133 monitoring wells for continuous monitoring of groundwater levels. Time-series hydrographs of groundwater level data are presented along with pertinent construction and location information for each well.

54 ENVIRONMENTAL SCIENCES↗

Control Point Analysis comparison for 3 different treatment planning and delivery complexity levels using a commercial 3-dimensional diode array

To investigate the use of “Control Point Analysis” (Sun Nuclear Corporation, Melbourne, FL) to analyze and compare delivered volumetric-modulated arc therapy (VMAT) plans for 3 different treatment planning complexity levels. A total of 30 patients were chosen and fully anonymized for the purpose of this study. Overall, 10 lung stereotactic body radiotherapy (SBRT), 10 head-and-neck (H and N), and 10 prostate VMAT plans were generated on Pinnacle{sup 3} and delivered on a Varian linear accelerator (LINAC). The delivered dose was measured using ArcCHECK (Sun Nuclear Corporation, Melbourne, FL). Each plan was analyzed using “Sun Nuclear Corporation (SNC) Patient 6” and “Control Point Analysis.” Gamma passing percentage was used to assess the differences between the measured and planned dose distributions and to assess the role of various control point binning combinations. Of the different sites considered, the prostate cases reported the highest gamma passing percentages calculated with “SNC Patient 6” (97.5% to 99.2% for the 3%, 3 mm) and “Control Point Analysis” (95.4% to 98.3% for the 3%, 3 mm). The mean percentage of passing control point sectors for the prostate cases increased from 51.8 ± 7.8% for individual control points to 70.6 ± 10.5% for 5 control points binned together to 87.8 ± 11.0% for 10 control points binned together (2%, 2-mm passing criteria). Overall, there was an increasing trend in the percentage of sectors passing gamma analysis with an increase in the number of control points binned together in a sector for both the gamma passing criteria (2%, 2 mm and 3%, 3 mm). Although many plans passed the clinical quality assurance criteria, plans involving the delivery of high Monitor Unit (MU)/control point (SBRT) and plans involving high degree of modulation (H and N) showed less delivery accuracy per control point compared with plans with low MU/control point and low degree of modulation (prostate)

61 RADIATION PROTECTION AND DOSIMETRY↗

Dead-time optimization for SiC based voltage source converters using online condition monitoring

This paper introduces a dead-time optimization technique for a 2-level voltage source converter (VSC) using turn-off transition monitoring. Dead-time in a VSC impacts power quality, reliability, and efficiency. Silicon carbide (SiC) based VSCs are more sensitive to dead-time from increased reverse conduction losses and turn-off time variability with operating conditions and load characteristics. An online condition monitoring system for SiC devices has been developed using gate drive assist circuits and a micro-controller. It can be leveraged to monitor turn-off time and indicate the optimal dead-time in each switching cycle of any converter operation. It can also be used to specify load current polarity, which is needed for dead-time optimization in an inverter. This is an important distinction from other inverter dead-time elimination/optimization schemes as current around the zero current crossing is hard to accurately detect. A 1kW half-bridge inverter was assembled to test the turn-off time monitoring and dead-time optimization scheme. Results show 91% reduction in reverse conduction power losses in the SiC devices compared to a set dead-time of 500ns switching at 50 kHz.

Dyer, Jacob↗

Data Fusion for Urban Air Quality Assessment & Forecasting

This presentation provides an overview for our funded project with NASA's Health and Air Quality Applied Sciences Program. The project will expand an existing air quality data fusion tool implemented in Google Earth Engine (GEE) by our project team members at Sonoma Technology, Inc. (STI), a private air quality data company. We will expand the capabilities of this tool using new methods developed by the NASA GMAO which will give it the capability of providing sub-city scale resolution and hourly frequency estimates and forecasts of three key air quality indicators: surface-level particulate matter (PM2.5), nitrogen dioxide (NO2), and ozone (O3). We will combine a variety of Earth Observations including satellite data, global air quality forecasts, and local data from regulatory-grade monitors and/or low cost sensors. We will implement the new data fusion capabilities into the existing GEE tool in consultation with our end-users to best address their needs for sub-city scale air quality estimates and forecasts.

K Emma Knowland↗

Novel Protein Crystal Growth Electrochemical Cell For Applications in X-ray Diffraction and Atomic Force Microscopy

A new crystal growth cell based on transparent indium tin oxide (ITO) glass-electrodes for electrochemically assisted protein crystallization allows for reduced nucleation and crystal quality enhancement. The crystallization behavior of lysozyme and ferritin was monitored as a function of the electric current applied to the growth cell. The X-ray diffraction analysis showed that for specific currents, the crystal quality is substantially improved. No conformational changes were observed in the 3D crystallographic structures determined for crystals grown under different electric current regimes. Finally, the strong crystal adhesion on the surface of ITO electrode because of the electroadhesion allows a sufficiently strong fixing of the protein crystals, to undergo atomic force microscopy investigations in a fluid cell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ambient Monitoring for Sinclair and Dyes Inlets, Puget Sound, Washington: Chemical Analyses for 2012 Regional Mussel Watch

Under the Project ENVVEST Final Project Agreement, the Puget Sound Naval Shipyard & Intermediate Maintenance Facility (PSNS&IMF), Environmental Protection Agency (EPA), Washington State Department of Ecology (Ecology), and local stakeholders have worked collaboratively to improve the environmental quality of Sinclair and Dyes Inlets. A regional mussel monitoring program began in 2010 to assess the status and trend of ecological resources, assess the effectiveness of cleanup and pollution control measures, and determine if discharges from all sources are protective of beneficial uses including aquatic life. The program collected indigenous mussels to represent a time-integrated measure of bioavailable metals and organic chemicals present in the water column. This document supplements the 2010 indigenous mussel data with 2012 data to provide two years of data on the chemical residue of mussels present in the inter-tidal regions of Sinclair Inlet, Dyes Inlet, Port Orchard Passage, Rich Passage, Agate Passage, Liberty Bay, and Keyport Lagoon. The 2012 data set added one station at PSNS&IMF and one market samples from Penn Cove. Indigenous mussels were collected from a small boat and/or from along the shoreline, measured, composited, and analyzed for percent lipids, percent moisture, stable isotopes of carbon and nitrogen, and a suite of trace metals and organic contaminants. The trace metals included silver (Ag), arsenic (As), cadmium (Cd), copper (Cu), mercury (Hg), lead (Pb), and zinc (Zn). The organic contaminants included the list of NOAA Status and Trends 20 polychlorinated biphenyls (PCB) congeners and suite of parent and methylated polycyclic aromatic hydrocarbons (PAHs). The average lengths between the 2010 and 2012 data were generally less than 30% relative percent difference (RPD). Generally, the metals concentrations were lower in 2012 than 2010 with some notable exceptions in Sinclair Inlet and Rich Passage where increases in Ag, Hg, Pb, Cu, and Zn exceeded an RPD of 50% between years. However, they did not exceed the bioaccumulation critical values or the critical body residues corresponding to the no observed effect dose (NOED) and the lowest observed effect dose (LOED) with one exception. The Cd concentrations exceeded the NOED and LOED for the Manchester Lab Pier and the Pike Place Market samples. For the PAHs and PCB, the 2012 data were generally lower than 2010 and some cases significantly lower for PAHs and none of the available invertebrate benchmarks were exceeded.

Brandenberger, Jill M.↗

The NREL Sensor Laboratory: Status and Future Directions for Hydrogen Detection

The NREL Hydrogen Sensor Laboratory was commissioned in 2010 as a resource for the national and international hydrogen community to ensure the availability and proper use of hydrogen sensors. Since then, the Sensor Laboratory has provided unbiased verification of hydrogen sensor performance for sensor developers, end-users, and regulatory agencies and has also provided active support for numerous code and standards development organizations. Although sensor performance assessment remains a core capability, the mission of the NREL Sensor Laboratory has expanded toward a more holistic approach regarding the role of hydrogen detection and its implementation strategy for both assurance of facility safety as well as for process control applications. Active monitoring for detection of unintended releases has been identified by the NFPA 2 Storage Task Group as a viable approach for improving facility safety and lowering setbacks. The current research program for the Sensor Laboratory addresses both conventional and advanced developing detection strategies in response to the emerging large-scale markets, such as those envisioned by H2@Scale. These emerging hydrogen applications may require alternative detection strategies that supplement and may ultimately supplant the use of traditional sensors for monitoring hydrogen releases. Research focus areas for the NREL Sensor Laboratory now encompasses the characterization of released hydrogen behavior to optimize detection strategies for both indoor and outdoor applications, advanced methods of hydrogen leak detection such as hydrogen wide area monitoring approaches for large scale and distributed applications, the incorporation of active monitoring as a risk reduction strategy to improve safety at hydrogen facilities, and continuing support of hydrogen safety codes and standards. In addition to assurance of safety, detection will be critical for process control applications, such as hydrogen fuel quality verification for fuel cell vehicle applications and for monitoring and controlling of hydrogen-natural gas blend composition.

codes and standards↗

Bluetooth(Registered Trademark) Heart Rate Monitors for Spaceflight

Heart rate monitoring is required during exercise for crewmembers aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data is required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth® heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health on board ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) was worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_RHM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the two data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. REULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6%error), followed by CS4 (3.3%error), CS3 (6.4%error), and CS2 (9.2%error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to get the best quality data. CS2 will be used in an ISS Bluetooth validation study, because it simultaneously transmits Magnetic Pulse which is integrated with existing exercise hardware on ISS. The simultaneous data streams allow for beat to beat comparison between the current ISS standard and CS2.Upon Bluetooth(Registered Trademark) validation aboard ISS, down select of a new BT_HRM for operational use will be made.

Buxton, Roxanne E.↗

Bluetooth Heart Rate Monitors For Spaceflight

Heart rate monitoring is required for crewmembers during exercise aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data are required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health aboard the ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) were worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_HRM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the 2 data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. RESULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6% error), followed by CS4 (3.3% error), CS3 (6.4% error), and CS2 (9.2% error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, but unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to obtain the best quality data. CS2 will be used in an ISS Bluetooth validation study, because it simultaneously transmits magnetic pulse that is integrated with existing exercise hardware on ISS. The simultaneous data streams allow for beat-to-beat comparison between the current ISS standard and CS2. Upon Bluetooth validation aboard ISS, the research team will down select a new BT_HRM for operational use.

Buxton, R. E.↗

Data Quality Analysis and Solutions for Distribution-Level PMUs

Synchrophasors provide promising enhancement to the distribution system monitoring. However, different from transmission systems, distribution systems are usually with higher noise, phase unbalance, and distributed energy resources. All of these could impair the data quality of distribution-level phasor measurement units (D-PMUs) and thus deteriorate the performance of D-PMU based applications. Therefore, the data quality of D-PMU should be evaluated to ensure the effectiveness of D-PMU based applications. In this paper, factors in distribution systems that could jeopardize D-PMU data quality are evaluated. The impact of data quality on D-PMU applications is analyzed. Finally, solutions are proposed to improve D-PMU data quality to satisfy these requirements. This work provides effective methods to improve the performance of distribution-level grid monitoring using synchrophasor measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Healthy Indoor Air Quality: A Guide to Understanding Pollutants in Extreme Cold Climates

Internal air quality management through commonly supported recommendations in extreme cold weather climates is complicated by cold air infiltration. Air filtration and IAQ monitoring, through central and stand-alone systems can improve internal air quality to the benefit of occupant health and safety. This fact sheet includes reference information for pollutants, sources, health effects, and mitigation strategies.

cold climate↗

Microbiological, Geochemical and Hydrologic Processes Controlling Uranium Mobility: An Integrated Field-Scale Subsurface Research Challenge Site at Rifle, Colorado, Quality Assurance Project Plan

The U.S. Department of Energy (DOE) is cleaning up and/or monitoring large, dilute plumes contaminated by metals, such as uranium and chromium, whose mobility and solubility change with redox status. Field-scale experiments with acetate as the electron donor have stimulated metal-reducing bacteria to effectively remove uranium [U(VI)] from groundwater at the Uranium Mill Tailings Site in Rifle, Colorado. The Pacific Northwest National Laboratory and a multidisciplinary team of national laboratory and academic collaborators has embarked on a research proposed for the Rifle site, the object of which is to gain a comprehensive and mechanistic understanding of the microbial factors and associated geochemistry controlling uranium mobility so that DOE can confidently remediate uranium plumes as well as support stewardship of uranium-contaminated sites. This Quality Assurance Project Plan provides the quality assurance requirements and processes that will be followed by the Rifle Integrated Field-Scale Subsurface Research Challenge Project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗