Lead Isotope Fingerprinting of Nanoscale Mineral Particles via Single Particle Inductively Coupled Plasma Mass Spectrometry

Determining lead (Pb) isotopic ratios is of broad interest across chemical disciplines for source tracing and age determinations, but the technique is inherently limited when multiple sources of Pb are present in a single sample. Single particle methods offer a solution to directly resolve multiple distinct isotopic ratios within individual samples. In this study, single particle inductively coupled plasma-mass spectrometry (spICP-MS) was performed using time-of-flight (TOF) and multicollector (MC)-based platforms to measure the Pb isotopic composition of individual nanoscale particles. Distinct Pb isotope ratios were measured in particles from four powdered galena samples of different origins (average single-particle 206Pb/207Pb ratios ranging from 0.91 to 1.28) using both the TOF and the MC-based platforms. Differentiation of galena particles in a mixture (liberated grains and those hosted in a silicate matrix) was possible due to detecting their unique multielemental fingerprints. The differing behavior of the two galena samples during digestion was investigated; undigested galena particles trapped within silicate minerals were detected using spICP-MS, which has implications for Pb recovery in bulk-scale isotopic analysis. The multinuclide detection capability of the ICP-TOF-MS instrument allowed for the simultaneous detection of secondary constituent elements within the nanoparticles and the identification of multiple populations of isotopically distinct Pb-bearing particles in a copper ore sample, whereas the increased sensitivity of the MC instrument enabled quantification of 204Pb, allowing differentiation using multiple isotopic ratios. A single particle isotope ratio analysis module was developed within an open-source spICP-TOF-MS data processing platform, enabling its adoption across chemical disciplines.

Goodman, Aaron J. [University of Montreal, Quebec,↗

Determination of the Spectral Index in the Fission Spectrum Energy Regime

Neutron reaction cross sections play a vital role in tracking the production and destruction of isotopes exposed to neutron fluence. They are central to the process of reconciling the initial and final atom inventories. Measurements of irradiated samples by radiochemical methods in tangent with an algorithm are used to evaluate the fluence a sample is exposed to over the course of the irradiation. This algorithm is the Isotope Production Code (IPC) created and used by the radiochemistry data assessment team at Los Alamos National Laboratory (LANL). An integral result is calculated by varying the total neutron fluence seen by a sample. A sample, irradiated in a critical assembly, will be exposed to a unique neutron flux defined by the neutron source and distance of the sample from the source. Neutron cross sections utilized are a function of the hardness of the neutron spectrum at the location of irradiation. A spectral index is used an indicator of the hardness of the neutron spectrum. Cross sections fit forms applied in IPC are collapsed from a LANL 30-group energy structure. Several decades of research and development have been performed to formalize the current IPC cross section library. Basis of the current fission spectrum neutron reaction cross section library is rooted in critical assembly experiments performed from the 1950’s through the early 1970’s at LANL. The focus of this report is development of the spectral index used an indicator of the hardness of the neutron spectrum in the fission spectrum energy regime.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experiments regarding methylphosphonic acid in proficiency test Sample 445

Samples 445/07 and 444/07 (blank) were extracted, in triplicate, by three different extraction methods – column elution, gentle rocking, and agitation with a vortex mixer. The recoveries for MPA differed depending on the extraction method used. In Sample 445/07, MPA was measured at ~2 μg/g (~20% recovery) when extracted by column elution and at ~1 μg/g when gentle rocking or vortex mixing was used. In addition, the soil matrix was observed to cause some ionization suppression effects when LC/MS analysis was used. The results of our experiments support the findings of the Sample Preparation Laboratory and suggest that MPA should remain a scoring chemical for the 44th OPCW PT.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: Non-invasive optical method for rapid determination of alignment degree of oriented nanofibrous layers

This paper presents a rapid non-destructive method that provides information on the anisotropic internal structure of nanofibrous layers. A laser beam of a wavelength of 632.8 nm is directed at and passes through a nanofibrous layer prepared by electrostatic spinning. Information about the structural arrangement of nanofibers in the layer is directly visible in the form of a diffraction image formed on a projection screen or obtained from measured intensities of the laser beam passing through the sample which are determined by the dependency of the angle of the main direction of polarization of the laser beam on the axis of alignment of nanofibers in the sample. Both optical methods were verified on Polyvinyl alcohol (PVA) nanofibrous layers (fiber diameter of 470 nm) with random, single-axis aligned and crossed structures. The obtained results match the results of commonly used methods which apply the analysis of electron microscope images. The presented simple method not only allows samples to be analysed much more rapidly and without damaging them but it also makes possible the analysis of much larger areas, up to several square millimetres, at the same time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Leverage Score Sampling for Parametric PDEs (Final Technical Report)

This final technical report summarizes the accomplishments of work performed under DOE Office of Science Award DE-SC0022266, which is titled “Leverage Score Sampling for Parametric PDEs”. The goal of the project was to extend methods from Randomized Numerical Linear Algebra (RandNLA) to tackle central computational challenges in model order reduction and uncertainty quantification (UQ) for parametric partial differential equations (PDEs). In particular, we sought to use importance sampling methods originally developed for RandNLA to develop sample efficient active learning algorithms for approximating high-dimensional scalar functions, e.g. by polynomials, Gaussian process models, and simple neural networks. Such methods can be immediately applied to developing surrogate models or to approximating quantity of interest (QoI) surfaces. In the context of PDEs, each sample used for learning equates to the solution of the differential equation for a particular set of parameters, so sample efficiency translates to improved computational efficiency for a variety of downstream tasks.

97 MATHEMATICS AND COMPUTING↗

Hanging drop sample preparation improves sensitivity of spatial proteomics

Spatial proteomics holds great promise for revealing tissue heterogeneity in both physiological and pathological conditions. However, one significant limitation of most spatial proteomics workflows is the requirement of large sample amounts that blurs cell-type-specific or microstructure-specific information. In this study, we developed an improved sample preparation approach for spatial proteomics and integrated it with our previously-established laser capture microdissection (LCM) and microfluidics sample processing platform. Specifically, we developed a hanging drop (HD) method to improve the sample recovery by positioning a nanowell chip upside-down during protein extraction and tryptic digestion steps. Compared with the commonly-used sitting-drop method, the HD method keeps the tissue pixel away from the container surface, and thus improves the accessibility of the extraction/digestion buffer to the tissue sample. The HD method can increase the MS signal by 7 fold, leading to a 66% increase in the number of identified proteins. An average of 721, 1489, and 2521 proteins can be quantitatively profiled from laser-dissected 10 μm-thick mouse liver tissue pixels with areas of 0.0025, 0.01, and 0.04 mm 2 , respectively. The improved system was further validated in the study of cell-type-specific proteomes of mouse uterine tissues.

47 OTHER INSTRUMENTATION↗

Development of solid materials for UF 6 sampling: FY16 Annual Report

A handheld implementation of the ABACC-developed Cristallini method, which captures uranium hexafluoride samples as an inert salt, was organized in FY17 and succeeded in demonstrating the handheld sampler concept with reactive hexafluoride gases. The Cristallini method relies on the use of a hydrated substrate to react the incoming hexafluoride resulting in the formation of a stable uranyl fluoride salt. The Cristallini method has been demonstrated as a facility modification installed near the sampling tap of a gas centrifuge enrichment plant. While very successful in reducing the hazards of uranium hexafluoride sample, the method still takes a considerable amount of time and can only be used in facilities where the apparatus has been installed; this arrangement generally prohibits the sampling of filled cylinders that have already exited the facility and have been deposited in the on-site tank storage yard. The handheld unit under development will allow the use of the Cristallini method at facilities that have not been converted as well as tanks in the storage yard. The handheld system utilizes an active vacuum system, rather than a passive vacuum system in the facility setup, to drive the uranium hexafluoride onto the adsorbing media. The handheld unit will be battery operated for fully autonomous operation and will include onboard pressure sensing and flushing capability. To date, the system concept of operations was demonstrated with tungsten hexafluoride that showed the active vacuum pump with multiple cartridges of adsorbing media was viable. Concurrently, the hardened prototype system was developed and tested; removable sample cartridges were developed (the only non-COTS component to date); and preparations were made for uranium tests and a domestic field test.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CHARACTERIZING THE GALACTIC WHITE DWARF BINARY POPULATION WITH SPARSELY SAMPLED RADIAL VELOCITY DATA

We present a method to characterize statistically the parameters of a detached binary sample-binary fraction, separation distribution, and mass-ratio distribution-using noisy radial velocity data with as few as two, randomly spaced, epochs per object. To do this, we analyze the distribution of {Delta}RV{sub max}, the maximum radial velocity difference between any two epochs for the same object. At low values, the core of this distribution is dominated by measurement errors, but for large enough samples there is a high-velocity tail that can effectively constrain the parameters of the binary population. We discuss our approach for the case of a population of detached white dwarf (WD) binaries with separations that are decaying via gravitational wave emission. We derive analytic expressions for the present-day distribution of separations, integrated over the star formation history of the Galaxy, for parameterized initial WD separation distributions at the end of the common-envelope phase. We use Monte Carlo techniques to produce grids of simulated {Delta}RV{sub max} distributions with specific binary population parameters, and the same sampling cadences and radial velocity errors as the observations, and we compare them to the real {Delta}RV{sub max} distribution to constrain the properties of the binary population. We illustrate the sensitivity of the method to both the model and observational parameters. In the particular case of binary WDs, every model population predicts a merger rate per star which can easily be compared to specific Type Ia supernova rates. In a companion paper, we apply the method to a sample of {approx}4000 WDs from the Sloan Digital Sky Survey. The binary fractions and separation distribution parameters allowed by the data indicate a rate of WD-WD mergers per unit stellar mass in the Galactic disk, {approx}1 Multiplication-Sign 10{sup -13} mergers yr{sup -1} M{sup -1}{sub Sun }, remarkably similar to the rate per unit mass of Type Ia supernovae in Milky Way like galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Integrated ‘omics analysis for studying the microbial community response to a pH perturbation of a cellulose-degrading bioreactor culture

Propionate accumulation is a common indicator of process imbalances in anaerobic bioreactor systems. The accumulation of propionate can occur due to low retention rates, hydrogen accumulation, or mechanical changes affecting the proximity between propionate oxidizers and partner species, thereby preventing necessary electron transfer. Few studies, however, have observed the changes in microbial community structure during propionate accumulation. We used 454 pyrosequencing of 16S rDNA to evaluate the community membership during propionate accumulations in replicate bioreactors with rumen based cultures. Half of the culture volume from a parent reactor was transferred to a sterile “daughter” reactor, and both systems were run identically. Both reactors experienced a propionate accumulation after roughly 10 days, with the propionate accumulation being less pronounced in the parent reactor as compared to the daughter reactor. Non-metric multidimensional scaling (NMDS) was used to determine clustering patterns of the samples, and correlative methods were used to determine which OTUs were significantly associated with the movements of samples along the NMDS axes. The presence of Saccharofermentans characterized the position of early samples, whereas the presence of Ruminococcus and Succiniclasticum were more indicative of the positions of later samples. Hydrogen accumulation and low sequence counts indicated low methanogen activity. Although both reactor systems were closed to microbial inputs due to the sterilization of influent media, we recorded significant increases in reactor diversity over time. This suggests that changes in the abundances of dominant community members may affect the sequencing of rare taxa within samples.

59 BASIC BIOLOGICAL SCIENCES↗

Particle Release Experiment (PRex) (Final Report)

An experiment to release radioactive particles representative of small-scale venting from an underground nuclear test was conducted to gather data in support of treaty verification and monitoring activities. For this experiment, a CO 2 -driven “air cannon” was used to release La-140 at ambient temperatures. Lanthanum-140 was chosen to represent the fission fragments because of its short half-life and prominent gamma-ray emissions; the choice was also influenced by the successful production and use of La-140 with low levels of radioactive contaminants in a Defence Research and Development Canada Field Trial. The source was created through activation of high-purity natural lanthanum oxide at the reactor of Washington State University, Pullman, Washington. Multiple varieties of witness plates and air samplers were laid in an irregular grid covering the area over which the plume was modeled to deposit. Aerial survey, a NaI(Tl) mobile spectrometer, and handheld and backpack instruments ranging from polyvinyl toluene to high-purity germanium were used to survey the plume. Additionally, three varieties of soil sampling were investigated. The relative sensitivity and utility of sampling and survey methods are discussed in the context of On-Site Inspection. The measurements and samples show a high degree of correlation and form a valuable set of test data.

54 ENVIRONMENTAL SCIENCES↗

Characterization of the March 2017 tank 10 surface sample (combination of HTF-10-17-30 AND HTF-10-17-31) and variable depth sample (combination of HTF-10-17-32 and HTF-10-17-33)

Two surface samples (HTF-10-17-30 and HTF-10-17-31) and two variable depth samples (HTF-10-17-32 and HTF-10-17-33) were collected from SRS Tank 10 during March 2017 and submitted to SRNL for characterization. At SRNL, the two surface samples were combined in one container, the two variable depth samples (VDSs) were combined in another container, and then the two composite samples were each characterized by a series of physical, ionic, radiological, and elemental analysis methods. The surface sample composite was characterized primarily for Tank Farm corrosion control purposes, while the VDS composite was characterized primarily for Tank Closure Cesium Removal (TCCR) purposes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laser Ablation, Absorbance Ratio Spectrometry (LAARS) Assay Performance Study (FY2018 Annual Report)

The International Atomic Energy Agency (IAEA) has a long history of testing and using laser-based technologies for a variety of safeguards applications. Notable laser-based on-site applications include: 3-dimensional laser range (3DLR) instruments, used for facility design information and verification (DIV); laser measurements to verify unique labels and detect signs of tampering; and laser spectroscopy, for non-contact process monitoring. The IAEA is also evaluating analytical laboratory instruments, such as laser-ablation inductively-coupled plasma mass spectrometry (LA-ICP-MS) for interrogating individual particles to determine uranium isotopic ratios in collected environment samples. Recent laser technology advancements will continue to fuel future IAEA adoption of new and novel laser-based safeguards tools. Pacific Northwest National Laboratory (PNNL) is developing one such tool, called the Laser Ablation, Absorbance Ratio Spectrometry (LAARS) technology, which is designed to provide high-fidelity 235 U/ 238 U isotope ratio measurements to support either on-site enrichment plant or off-site laboratory destructive assay (DA). Analyzing uranium hexafluoride (UF 6 ) DA samples on-site by LAARS could provide early indication of discrepancies with operator declarations during physical inventory verifications, so that such discrepancies could be addressed immediately, rather than after off-site analysis is completed. The IAEA is also seeking on-site DA options, because sample shipping time can be long and evolving restrictions on radioactive/corrosive material shipments may increasingly limit the IAEA’s ability to easily transport UF 6 samples. Routine on-site LAARS analysis could provide timely assay results and reduce the DA sample shipment inventory to just those needed for more definitive determination. A laboratory-based LAARS instrument could also provide rapid, cost-effective prescreening of selected DA samples shipped to the IAEA’s Nuclear Materials Laboratory in Seibersdorf, Austria. PNNL has also developed a complementary UF 6 sampling technology and method, called the Single-Use Destructive Assay (SUDA) sampler to easily collect DA samples that are ideal for on-site analysis by LAARS. Combining the LAARS and SUDA sampler technologies could provide a powerful new on-site DA option for the IAEA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimized sub-sampling in an electron microscope

Disclosed are methods for optimized sub-sampling in an electron microscope. With regard at least to utilization of electron dose budgets, of time for acquisition of measurements, and of computing/processing capabilities, very high efficiencies can be achieved by informing and/or adapting subsequent sub-sampling measurements according to one or more earlier-acquired sparse datasets and/or according to analyzes thereof.

Stevens, Andrew J.↗

Modeling of Hidden Structures Using Sparse Chemical Shift Data from NMR Relaxation Dispersion

NMR relaxation dispersion measurements report on conformational changes occurring on the μs-ms timescale. Chemical shift information derived from relaxation dispersion can be used to generate structural models of weakly populated alternative conformational states. Current methods to obtain such models rely on determining the signs of chemical shift changes between the conformational states, which are difficult to obtain in many situations. Here, we use a “sample and select” method to generate relevant structural models of alternative conformations of the C-terminal-associated region of Escherichia coli dihydrofolate reductase (DHFR), using only unsigned chemical shift changes for backbone amides and carbonyls ( 1 H, 15 N, and 13 C'). We find that CS-Rosetta sampling with unsigned chemical shift changes generates a diversity of structures that are sufficient to characterize a minor conformational state of the C-terminal region of DHFR. The excited state differs from the ground state by a change in secondary structure, consistent with previous predictions from chemical shift hypersurfaces and validated by the x-ray structure of a partially humanized mutant of E. coli DHFR (N23PP/G51PEKN). The results demonstrate that the combination of fragment modeling with sparse chemical shift data can determine the structure of an alternative conformation of DHFR sampled on the μs-ms timescale. Such methods will be useful for characterizing alternative states, which can potentially be used for in silico drug screening, as well as contributing to understanding the role of minor states in biology and molecular evolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Doping Effects on Multivalence States, Electronic Structure, and Optical Band Gap in LaCrO 3 under Varied Atmospheres: An Integrated Experimental and Density Functional Theory Study

Doping effects on the valence state, electronic structure, and optical band and the effects on electrical conductivity were studied on the doped lanthanum chromite (LaCrO 3 ) system. The specific compositions studied were La 1–x Ca x CrO 3 (LCCx), La 1–x Sr x CrO 3 (LSCx), and La 0.8 Sr 0.2 Cr 1–x Mn x O 3 (LSCMx) (0.1 ≤ x ≤ 0.4). The powders were synthesized using a modified Pechini sol–gel method, and the ceramic samples were densified using a reactive sintering method resulting in densities >96% theoretical. X-ray photoelectron spectroscopy (XPS) was completed to characterize the defect states and cationic valence compensation as a result of divalent (Ca 2+ or Sr 2+ ) and trivalent (Mn 3+ ) substitutions. XPS was completed for samples tested in oxidizing and reducing atmospheres (up to 1500 °C), which provided insights into the oxidation state transitions induced by the Ca 2+ and Sr 2+ dopants. The work notably demonstrated, for the first time, the oxidation/reduction transitions of Cr 4+ to Cr 3+ in Sr 2+ /Mn 3+ co-doped samples under reducing atmospheres. Reflectance UV–vis spectrophotometry optical band gap measurements were also completed for the same materials; a decrease in the optical band gap (2.81–3.12 eV) was shown with increased substitution, suggesting electronic structure modifications in the LaCrO 3 perovskite. Density functional theory calculations validated experimental trends, predicting a diminishing band gap with a rising dopant concentration. The transition in Cr oxidation states was attributed to the presence of divalent/trivalent cations. These findings contribute some insights into methods to tune the LaCrO 3 electrical properties for various low- and high-temperature applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization and differentiation of aluminum powders used in improvised explosive devices – Part 1: Proof of concept of the utility of particle micromorphometry

Abstract Aluminum (Al) powders are commonly used in improvised explosive devices as metallic fuels, a component of explosive mixtures. These powders can be obtained readily from industrial‐scale and consumer products, and produced using unsophisticated “kitchen chemistry” techniques. This research demonstrates the potential of automated particle micromorphometry for comparisons between known source and questioned Al powders recovered from IEDs, as well as for insight into the method of Al powder manufacture. Al powder samples were obtained from legitimate manufacturers, and 56 samples were produced “in‐house” from Al‐containing spray paints and ball‐milled Al foils. Transmitted light microscope images of Al powder particles were acquired using an automated stage with automated z‐focus; 17 size and shape parameters were measured for all particles. Approximately 37,000–2,500,000 particles/sample were analyzed using an open‐source statistical package with customized code. Dimensionality reduction was required for processing the large datasets: eight of the 17 measured variables were selected based on inspection of the correlation matrix. Data from four subsamples from each of the 56 samples produced using “in‐house” methods were analyzed using ANOVA to assess the within‐ and between‐sample variation. High within‐sample variation was noted; however, ANOVA and post‐hoc Tukey's honestly significant difference (HSD) tests demonstrated that the between‐sample variation was substantially larger than the within‐sample variation. Each sample could be differentiated from all other samples in the test set. Future experiments will focus on ways to reduce the within‐sample variation, and additional statistical and microanalytical methods to classify sources and confidently constrain the method of Al powder manufacture.

Baldaino, JenaMarie↗

Absolute Efficiency Calibration of a Beta-Gamma Detector

Abstract- Identification and quantification of nuclear events such as the Fukushima reactor failure and nuclear explosions rely heavily on the accurate measurement of radioxenon releases. One radioxenon detection method depends on detecting beta-gamma coincident events paired with a stable xenon measurement to determine the concentration of a plume. Like all measurements, the beta-gamma method relies on knowing the detection efficiency for each isotope measured. Several methods are commonly used to characterize the detection efficiency for a beta-gamma detector. The most common method is using a NIST certified sealed source to determine the efficiency. A second method determines the detection efficiencies relative to an already characterized detector. Finally, a potentially more accurate method is to use the expected sample to perform an absolute efficiency calibration; in the case of a beta-gamma detector, this relies on radioxenon gas samples. The complication of the first method is it focuses only on the gamma detectors and does not offer a solution for determining the beta efficiency. The second method listed is not similarly constrained, however it relies on another detector to have a well-known efficiency calibration. The final method using actual radioxenon samples to make an absolute efficiency determination is the most desirable, but until recently it was not possible to produce all four isotopically pure radioxenon. The production, by University of Texas (UT), of isotopically pure radioxenon has allowed the beta-gamma detectors to be calibrated using the absolute efficiency method. The first four radioxenon isotope calibration will be discussed is this paper.

absolute efficiency calibration beta-gamma↗

Environmental exposures to lead, mercury, and cadmium among South Korean teenagers (KNHANES 2010–2013): Body burden and risk factors

Introduction: Limited information is available on the association of age and sex with blood concentrations of heavy metals in teenagers. In addition, factors such as a shared family environment may have an association. We analyzed data from the Korean National Health and Nutrition Examination Survey (KNHANES, 2010–2013) to determine whether blood levels of heavy metals differ by risk factors such as age, sex, and shared family environment in a representative sample of teenagers. Methods: This study used data obtained in the KNHANES 2010–2013, which had a rolling sampling design that involved a complex, stratified, multistage, probability-cluster survey of a representative sample of the non-institutionalized civilian population in South Korea. Our cross-sectional analysis was restricted to teenagers and their parents who completed the health examination survey, and for whom blood measurements of cadmium, lead, and mercury were available. The final analytical sample consisted of 1585 teenagers, and 376 fathers and 399 mothers who provided measurements of blood heavy metal concentrations. Results: Male teenagers had greater blood levels of lead and mercury, but sex had no association with blood cadmium level. There were age-related increases in blood cadmium, but blood lead decreased with age, and age had little association with blood mercury. The concentrations of cadmium and mercury declined from 2010 to 2013. The blood concentrations of lead, cadmium, and mercury in teenagers were positively associated with the levels in their parents after adjustment for covariates. Conclusion: Our results show that blood heavy metal concentrations differ by risk factors such as age, sex, and shared family environment in teenagers. - Highlights: • This study was based on data obtained by KNHANES 2010–2013. • Male had greater blood levels of lead and mercury, and there were age-related increases in blood cadmium in Korean adolescents. • The blood concentrations of lead, cadmium, and mercury in adolescents were positively associated with the levels in their parents.