Search NASA⌕ Search

SEARCH · Search NASA

Results for “scan pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

SU-F-19A-07: Is a Day30 Scan Necessary to Evaluate Activity-Based Regulatory Compliance in Permanent Interstitial Brachytherapy for Prostate Cancer?

Purpose: To evaluate the Medical Event (ME) criteria for I-125 prostate implants based on the assessment of post implant dosimetry on “Day0”/“Day30” imaging. The new ME criteria do not mandate a timeframe for this assessment. The compliance criteria are: more than 80% of the activity from the written directive for treatment site (TS) must be implanted inside TS, and doses to 1cc of either uninvolved rectum (D1-UR) or uninvolved bladder (D1-UB), or 2cc of other non-specified tissue (D2-UT) must be less than 150% of the planned dose. Methods: “Day0”/“Day30” post-implant analyses for 25 patients were evaluated. Treatment plans had a peripheral loading pattern with 2 core needles placed at least 10 mm away from urethra, with several seeds planned outside of the prostate for adequate target coverage. TS were a uniform 5 mm expansion of the prostate, except posteriorly (no expansion). Results: “Day0”/“Day30”analyses found no MEs. The relative changes for D1-UR, D1-UB, and D2-UT were (ranges): [−37.0, 38.2]%, [−96.5, 74.7]%, and [−41.2, 37.7]%. Furthermore, changes did not correlate with prostate volume changes of −18.7% [σ:16.0%, range:−60.5%, +6.4%]. These unfavorable changes did not lead to ME at “Day30” because these values were generally well below 150% at “Day0”. However, D2-UT dose values exceeded those for D1-UR and D1-UB at both “Day0”/“Day30”. Conclusion: The total activity was relatively insensitive to changes in target volume from “Day0” to ”Day30”. The dose metrics of interest, albeit susceptible to large, often unfavorable changes, remained less than the 150% threshold. Data from this study suggest that “Day0” can be used for the regulatory compliance evaluation. However, further evaluation at “Day30” is advisable if D2-UT is 110% or above (based on the largest D2-UT increase of 37.7% observed in this patient population). Future rigorous statistical analysis of a larger cohort will afford a refinement of this recommendation.

60 APPLIED LIFE SCIENCES↗

Tuning the Magnetic Properties of ZnFe{sub 2}O{sub 4} Nanoparticles Through Partial Doping and Annealing

The aim of this study was to investigate the effect of annealing temperature and cobalt cation (Co{sup 2+}) doping on the magnetic properties of zinc ferrite (ZFO) nanoparticles. The nanoparticles were prepared through sol-gel combustion process with citric acid as the fuel. The obtained nanoparticles were annealed at several temperatures from 300 to 1000 °C for 2 h. Spinel formation was proved by X-ray diffraction (XRD) patterns, and the average crystallite size in all samples was estimated between 22 and 32 nm. It is worthwhile to mention that Fe{sub 2}O{sub 3} and ZnO are detected as the medium phases. Meanwhile, Fe{sub 2}O{sub 3} phase transformation to the other allotropes has happened around 400 °C and was characterized via the simultaneous thermal analysis (STA) and XRD. For higher annealing temperatures, diffusion has gradually been completed and, finally, the single phase of spinel structure was prepared at 1000 °C. In addition, field-emission scanning electron microscopy (FESEM) images revealed that the nanoparticle size after annealing was between 30 and 200 nm for the whole samples. The formation of the spinel phase was considered the most important factor on the magnetic properties of ZFO. Cobalt doping, annealing temperature, and also Fe{sub 2}O{sub 3} phase were the main factors on changing magnetic properties. Paramagnetic nanoparticles with higher coercivity for doped samples rather than un-doped samples have been obtained.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Local structure and composition studies of Li{sub 1.2}Ni{sub 0.2}Mn{sub 0.6}O{sub 2} by analytical electron microscopy.

Positive electrodes for Li-ion batteries based on Li[Li{sub 1/3-2x/3}Ni{sub x}Mn{sub 2/3-x/3}]O{sub 2} (0 {le} x {le} 0.5) compounds are of significant interest because of their ability to deliver reversible capacities exceeding 200 mAh g{sup -1}. In this article we describe the examination of Li{sub 1.2}Ni{sub 0.2}Mn{sub 0.6}O{sub 2} (x = 0.2 in Li[Li{sub 1/3-2x/3}Ni{sub x}Mn{sub 2/3-x/3}]O{sub 2}) samples by X-ray diffraction (XRD), high-resolution electron microscopy (HREM), scanning transmission electron microscopy (STEM), electron diffraction, X-ray energy dispersive spectroscopy (EDS), and electron energy loss spectroscopy (EELS). The studies were conducted on freshly prepared oxides, and on oxide electrodes that were electrochemically activated by cycling twice between 4.8 and 2.0 V vs. Li{sup +}/Li. Rectangular and parallelogram shaped dot arrays with a spacing of 0.43 nm observed in HREM and STEM images along the [10{bar 1}0] zone axis, as well as streaks at 1/3 n (11{bar 2}0) (n = integer) positions in corresponding electron diffraction patterns, indicated ordering of Li-ions in the transition-metal (TM) (0 0 0 1) layers following several stacking sequences, bounded by stacking faults, along the c-axis. Chemical analysis by EDS and EELS showed that Mn, Ni and O were present in all portions of the samples examined; no evidence of elemental segregation was observed either within the grains or at grain boundaries. The Li ordering on TM planes was significantly weaker but still discernable upon electrochemical activation of the oxide samples.

25 ENERGY STORAGE↗

Exploring the Limits of Bottom-Up Gold Filling to Fabricate Diffraction Gratings

Gold deposition on rotating disk electrodes, Bi 3+ adsorption on planar Au films and superconformal Au filling of trenches up to 45 μm deep are examined in Bi 3+ -containing Na 3 Au(SO 3 ) 2 electrolytes with pH between 9.5 and 11.5. Higher pH is found to increase the potential-dependent rate of Bi 3+ adsorption on planar Au surfaces, shortening the incubation period that precedes active Au deposition on planar surfaces and bottom-up filling in patterned features. Decreased contact angles between the Au seeded sidewalls and bottom-up growth front also suggest improved wetting. The bottom-up filling dynamic in trenches is, however, lost at pH 11.5. The impact of Au concentration, 80 mmol/L versus 160 mmol/L Na 3 Au(SO 3 ) 2 , on bottom-up filling is examined in trenches up to ≈ 210 μm deep with aspect ratio of depth/width ≈ 30. The microstructures of void-free, bottom-up filled trench arrays used as X-ray diffraction gratings are characterized by scanning electron microscopy (SEM) and Electron Backscatter Diffraction (EBSD), revealing marked spatial variation of the grain size and orientation within the filled features.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-Dimensional Imaging in Gynecologic Brachytherapy: A Survey of the American Brachytherapy Society

Purpose: To determine current practice patterns with regard to three-dimensional (3D) imaging for gynecologic brachytherapy among American Brachytherapy Society (ABS) members. Methods and Materials: Registered physician members of the ABS received a 19-item survey by e-mail in August 2007. This report excludes physicians not performing brachytherapy for cervical cancer. Results: Of the 256 surveys sent, we report results for 133 respondents who perform one or more implantations per year for locally advanced cervical cancer. Ultrasound aids 56% of physicians with applicator insertion. After insertion, 70% of physicians routinely obtain a computed tomography (CT) scan. The majority (55%) use CT rather than X-ray films (43%) or magnetic resonance imaging (MRI; 2%) for dose specification to the cervix. However, 76% prescribe to Point A alone instead of using a 3D-derived tumor volume (14%), both Point A and tumor volume (7%), or mg/h (3%). Those using 3D imaging routinely contour the bladder and rectum (94%), sigmoid (45%), small bowel (38%), and/or urethra (8%) and calculate normal tissue dose-volume histogram (DVH) analysis parameters including the D2cc (49%), D1cc (36%), D0.1cc (19%), and/or D5cc (19%). Respondents most commonly modify the treatment plan based on International Commission on Radiation Units bladder and/or rectal point dose values (53%) compared with DVH values (45%) or both (2%). Conclusions: More ABS physician members use CT postimplantation imaging than plain films for visualizing the gynecologic brachytherapy apparatus. However, the majority prescribe to Point A rather than using 3D image based dosimetry. Use of 3D image-based treatment planning for gynecologic brachytherapy has the potential for significant growth in the United States.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Respiratory Motion Perturbation Model Adaptable to Patient Breathing Irregularities

Purpose: To develop a physical, adaptive motion perturbation model to predict tumor motion using feedback from dynamic measurement of breathing conditions to compensate for breathing irregularities. Methods and Materials: A novel respiratory motion perturbation (RMP) model was developed to predict tumor motion variations caused by breathing irregularities. This model contained 2 terms: the initial tumor motion trajectory, measured from 4-dimensional computed tomography (4DCT) images, and motion perturbation, calculated from breathing variations in tidal volume (TV) and breathing pattern (BP). The motion perturbation was derived from the patient-specific anatomy, tumor-specific location, and time-dependent breathing variations. Ten patients were studied, and 2 amplitude-binned 4DCT images for each patient were acquired within 2 weeks. The motion trajectories of 40 corresponding bifurcation points in both 4DCT images of each patient were obtained using deformable image registration. An in-house 4D data processing toolbox was developed to calculate the TV and BP as functions of the breathing phase. The motion was predicted from the simulation 4DCT scan to the treatment 4DCT scan, and vice versa, resulting in 800 predictions. For comparison, noncorrected motion differences and the predictions from a published 5-dimensional model were used. Results: The average motion range in the superoinferior direction was 9.4 ± 4.4 mm, the average ΔTV ranged from 10 to 248 mm{sup 3} (−26% to 61%), and the ΔBP ranged from 0 to 0.2 (−71% to 333%) between the 2 4DCT scans. The mean noncorrected motion difference was 2.0 ± 2.8 mm between 2 4DCT motion trajectories. After applying the RMP model, the mean motion difference was reduced significantly to 1.2 ± 1.8 mm (P=.0018), a 40% improvement, similar to the 1.2 ± 1.8 mm (P=.72) predicted with the 5-dimensional model. Conclusions: A novel physical RMP model was developed with an average accuracy of 1.2 ± 1.8 mm for interfraction motion prediction, similar to that of a published lung motion model. This physical RMP was analytically derived and is able to adapt to breathing irregularities. Further improvement of this RMP model is under investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Foundations of machine learning for low-temperature plasmas: methods and case studies

Abstract Machine learning (ML) and artificial intelligence have proven to be an invaluable tool in tackling a vast array of scientific, engineering, and societal problems. The main drivers behind the recent proliferation of ML in practically all aspects of science and technology can be attributed to: (a) improved data acquisition and inexpensive data storage; (b) exponential growth in computing power; and (c) availability of open-source software and resources that have made the use of state-of-the-art ML algorithms widely accessible. The impact of ML on the field of low-temperature plasmas (LTPs) could be particularly significant in the emerging applications that involve plasma treatment of complex interfaces in areas ranging from the manufacture of microelectronics and processing of quantum materials, to the LTP-driven electrification of the chemical industry, and to medicine and biotechnology. This is primarily due to the complex and poorly-understood nature of the plasma-surface interactions in these applications that pose unique challenges to the modeling, diagnostics, and predictive control of LTPs. As the use of ML is becoming more prevalent, it is increasingly paramount for the LTP community to be able to critically analyze and assess the concepts and techniques behind data-driven approaches. To this end, the goal of this paper is to provide a tutorial overview of some of the widely-used ML methods that can be useful, amongst others, for discovering and correlating patterns in the data that may be otherwise impractical to decipher by human intuition alone, for learning multivariable nonlinear data-driven prediction models that are capable of describing the complex behavior of plasma interacting with interfaces, and for guiding the design of experiments to explore the parameter space of plasma-assisted processes in a systematic and resource-efficient manner. We illustrate the utility of various supervised, unsupervised and active learning methods using LTP datasets consisting of commonly-available, information-rich measurements (e.g. optical emission spectra, current–voltage characteristics, scanning electron microscope images, infrared surface temperature measurements, Fourier transform infrared spectra). All the ML demonstrations presented in this paper are carried out using open-source software; the datasets and codes are made publicly available. The FAIR guiding principles for scientific data management and stewardship can accelerate the adoption and development of ML in the LTP community.

Physics↗

Viable chemical approach for patterning nanoscale magnetoresistive random access memory

A reactive ion etching process with alternating Cl{sub 2} and H{sub 2} exposures has been shown to chemically etch CoFe film that is an integral component in magnetoresistive random access memory (MRAM). Starting with systematic thermodynamic calculations assessing various chemistries and reaction pathways leading to the highest possible vapor pressure of the etch products reactions, the potential chemical combinations were verified by etch rate investigation and surface chemistry analysis in plasma treated CoFe films. An ∼20% enhancement in etch rate was observed with the alternating use of Cl{sub 2} and H{sub 2} plasmas, in comparison with the use of only Cl{sub 2} plasma. This chemical combination was effective in removing metal chloride layers, thus maintaining the desired magnetic properties of the CoFe films. Scanning electron microscopy equipped with energy-dispersive x-ray spectroscopy showed visually and spectroscopically that the metal chloride layers generated by Cl{sub 2} plasma were eliminated with H{sub 2} plasma to yield a clean etch profile. This work suggests that the selected chemistries can be used to etch magnetic metal alloys with a smooth etch profile and this general strategy can be applied to design chemically based etch processes to enable the fabrication of highly integrated nanoscale MRAM devices.

36 MATERIALS SCIENCE↗

The Observed Variance Between Predicted and Measured Radiation Dose in Breast and Prostate Patients Utilizing an In Vivo Dosimeter

Purpose: Report the results of using a permanently implantable dosimeter in radiation therapy: determine specific adverse events, degree of migration, and acquire dose measurements during treatment to determine difference between expected and measured dose. Methods and Materials: The Dose Verification System is a wireless, permanently implantable metal-oxide semiconductor field-effect transistor dosimeter using a bidirectional antenna for power and data transfer. The study cohort includes 36 breast (33 patients received two devices) and 29 prostate (21 patients received two devices) cancer patients. A total of 1,783 and 1,749 daily dose measurements were obtained on breast and prostate patients, respectively. The measurements were compared with the planned expected dose. Biweekly computed tomography scans were obtained to evaluate migration and the National Cancer Institute's Common Toxicity Criteria, version 3, was used to evaluate adverse events. Results: Only Grade I/II adverse events of pain and bleeding were noted. There were only four instances of dosimeter migration of >5 mm from known factors. A deviation of {>=}7% in cumulative dose was noted in 7 of 36 (19%) for breast cancer patients. In prostate cancer patients, a {>=}7% deviation was noted in 6 of 29 (21%) and 8 of 19 (42%) during initial and boost irradiation, respectively. The two patterns of dose deviation were random and systematic. Some causes for these differences could involve organ movement, patient movement, or treatment plan considerations. Conclusions: The Dose Verification System was not associated with significant adverse events or migration. The dosimeter can measure dose in situ on a daily basis. The accuracy and utility of the dose verification system complements current image-guided radiation therapy and intensity-modulated radiation therapy techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Field retrieved photovoltaic backsheet survey from diverse climate zones: Analysis of degradation patterns and phenomena

Understanding the impact of climate stressors on photovoltaic (PV) backsheet degradation in real-use conditions is critical to improve the accelerated testing exposures, extend the backsheet lifetime, and increase the confidence in PV reliability. Here, in this work, a total of 33 PV module backsheets were retrieved from six climatic zones worldwide with 2 - 28 years of exposure. These modules included five types of backsheet air-side materials (or outer layer): poly(vinylidene fluoride) (PVDF), poly(tetrafluoroethylene-co-hexafluoropropylene-co-vinylidene fluoride) (THV), poly(vinyl fluoride) (PVF), poly(ethylene terephthalate) (PET), and polyamide (PA). Attenuated total reflection Fourier-transform infrared spectroscopy (ATR-FTIR) was used to identify air-side materials. The degradation induced color change, gloss loss, and chemical material changes analyzed using optical microscopy, differential scanning calorimetry (DSC), scanning electron microscopy (SEM), colorimetry (yellowness index (YI)), and gloss measurements. PVDF, THV, and PVF air-side layer backsheets, in particular PVF, had minimal degradation in the air-side layer appearance and chemical structures after exposure in different climatic zones. The PET air-side backsheets exhibited obvious color increase (22.55 YI units after about 9 years exposure) and the PA/PA/PA backsheets showed large gloss loss (up to 76.4 %) relative to the unexposed backsheets. Severe cracks between cells that penetrated through the entire thickness of backsheets are observed on PA/PA/PA backsheets after 4-6 years of exposure in 6 climatic zones. The current indoor exposure standards were not sufficient to identify this degradation type. However, fluoropolymer based PV backsheets showed lower levels of degradation predictors and increased climatic resistance. Specific samples (PVF) showed little change from baseline after 28 years of outdoor exposure.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

3D Reconstruction of a High-Energy Diffraction Microscopy Sample Using Multi-modal Serial Sectioning with High-Precision EBSD and Surface Profilometry

High-energy diffraction microscopy (HEDM) combined with in situ mechanical testing is a powerful nondestructive technique for tracking the evolving microstructure within polycrystalline materials during deformation. This technique relies on a sophisticated analysis of X-ray diffraction patterns to produce a three-dimensional reconstruction of grains and other microstructural features within the interrogated volume. However, it is known that HEDM can fail to identify certain microstructural features, particularly smaller grains or twinned regions. Characterization of the identical sample volume using high-resolution surface-specific techniques, particularly electron backscatter diffraction (EBSD), can not only provide additional microstructure information about the interrogated volume but also highlight opportunities for improvement of the HEDM reconstruction algorithms. In this study, a sample fabricated from undeformed “low solvus, high refractory” nickel-based superalloy was scanned using HEDM. The volume interrogated by HEDM was then carefully characterized using a combination of surface-specific techniques, including epi-illumination optical microscopy, zero-tilt secondary and backscattered electron imaging, scanning white light interferometry, and high-precision EBSD. Custom data fusion protocols were developed to integrate and align the microstructure maps captured by these surface-specific techniques and HEDM. The raw and processed data from HEDM and serial sectioning have been made available via the Materials Data Facility (MDF) at https://doi.org/10.18126/4y0p-v604 for further investigation.

36 MATERIALS SCIENCE↗

Czochralski growth and characterization of the multicomponent garnet (Lu 1/4 Yb 1/4 Y 1/4 Gd 1/4 ) 3 Al 5 O 12

This work demonstrates the potential for practical scalable growth of complex garnets and evaluates the implications of a multicomponent composition in the optical quality and elemental distribution of a Czochralski-grown crystal. Furthermore, our experimental approach was designed to elucidate the relation between a complex garnet composition ( Lu 1 / 4 Yb 1 / 4 Y 1 / 4 Gd 1 / 4 ) 3 Al 5 O 12 , crystal growth parameters, crystal structural, and elemental homogeneity. Our hypothesis is that combining multiple rare earths (REs) that will fractionally occupy the dodecahedral site in the aluminum garnet structure will result in a stable, single garnet compound that can be grown by the Czochralski method. Single-crystal and powder x-ray diffraction indicated a single garnet phase with an increasing unit cell volume from seed to tail. In addition, we propose that the pattern of elemental segregation will be based on the deviation of the ionic radius of each constituent RE from the average RE ionic radius of the multicomponent garnet. Electron probe microanalysis revealed that ions that are smaller than that average ( Lu 3 + and Yb 3 + ) are preferentially incorporated in the crystal, while elements that are larger than that average ( Gd 3 + ) are rejected. The ionic radius of Y 3 + is close to that average and yttrium segregation was minimal. The concentrations of the four REs are closer to stoichiometric on the tail end of the boule. Scanning electron microscopy and energy-dispersive x-ray spectroscopy analysis reveal Gd-rich inclusions with eutectic microstructures in the tail end of the boule.

36 MATERIALS SCIENCE↗

Plasmonic enhancement of thin-film solar cells using gold-black coatings

Coatings of conducting gold-black nano-structures on commercial thin-film amorphous-silicon solar cells enhance the short-circuit current by 20% over a broad spectrum from 400 to 800 nm wavelength. The efficiency, i.e. the ratio of the maximum electrical output power to the incident solar power, is found to increase 7% for initial un-optimized coatings. Metal blacks are produced cheaply and quickly in a low-vacuum process requiring no lithographic patterning. The inherently broad particle-size distribution is responsible for the broad spectrum enhancement in comparison to what has been reported for mono-disperse lithographically deposited or self-assembled metal nano-particles. Photoemission electron microscopy reveals the spatial-spectral distribution of hot-spots for plasmon resonances, where scattering of normally-incident solar flux into the plane increases the effective optical path in the thin film to enhance light harvesting. Efficiency enhancement is correlated with percent coverage and particle size distribution, which are determined from histogram and wavelet analysis of scanning electron microscopy images. Electrodynamic simulations reveal how the gold-black particles scatter the radiation and locally enhance the field strength.

14 SOLAR ENERGY↗

TiO{sub 2}/PANI And MWNT/PANI Composites Thin Films For Hydrogen Gas Sensing

The MWNT and TiO{sub 2} doped Polyaniline (PANI) composites were synthesized by In-situ chemical oxidative polymerization method at low temperature. The MWNT/PANI and TiO{sub 2}/PANI composite thin films were prepared using spin coating method onto finger type interdigited electrodes to develop the chemiresistor type gas sensor for hydrogen gas sensing application. It was observed that the MWNT and TiO{sub 2} doped PANI composite thin films show a higher response in comparision to neat PANI. The structural and morphological properties of these composite films were characterized by X-Ray differaction (XRD) pattern and sccaning electrone microscopy (SEM) respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of the barrier growth mode on the luminescence and conductivity micron scale uniformity of InGaN light emitting diodes

In this paper, we present a combined cathodoluminescence (CL) and electron beam induced current (EBIC) study of the optical and electrical properties of InGaN light emitting diodes grown using different active region growth methods. In one device, both the quantum wells and quantum barriers were deposited at their optimum temperatures (2 T), whereas in the other device, each barrier was grown in a two step process with the first few nanometers at a lower temperature (Q2T). It was found that in the Q2T sample, small micron scale domains of lower emission intensity correlate strongly to a lower EBIC signal, whereas in the 2 T sample which has a more uniform emission pattern and an anti-correlation exists between CL emission intensity and EBIC signal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interplay of hidden orbital order and superconductivity in CeCoIn5

Abstract Visualizing atomic-orbital degrees of freedom is a frontier challenge in scanned microscopy. Some types of orbital order are virtually imperceptible to normal scattering techniques because they do not reduce the overall crystal lattice symmetry. A good example is d xz / d yz (π,π) orbital order in tetragonal lattices. For enhanced detectability, here we consider the quasiparticle scattering interference (QPI) signature of such (π,π) orbital order in both normal and superconducting phases. The theory reveals that sublattice-specific QPI signatures generated by the orbital order should emerge strongly in the superconducting phase. Sublattice-resolved QPI visualization in superconducting CeCoIn 5 then reveals two orthogonal QPI patterns at lattice-substitutional impurity atoms. We analyze the energy dependence of these two orthogonal QPI patterns and find the intensity peaked near E = 0, as predicted when such (π,π) orbital order is intertwined with d -wave superconductivity. Sublattice-resolved superconductive QPI techniques thus represent a new approach for study of hidden orbital order.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Clinical evaluations of an amplitude-based binning algorithm for 4DCT reconstruction in radiation therapy

Purpose: Phase-binning algorithms are commonly utilized in 4DCT image reconstruction for characterization of tumor or organ shape and respiration motion, but breathing irregularities occurring during 4DCT acquisition can cause considerable image distortions. Recently, amplitude-binning algorithms have been evaluated as a potential improvement to phase-binning algorithms for 4DCT image reconstruction. The purpose of this study was to evaluate the performance of the first commercially available on-line retrospective amplitude-binning algorithm for comparison to the traditional phase-binning algorithm. Methods: Both phantom and clinical data were used for evaluation. A phantom of known geometry was mounted on a 4D motion platform programmed with seven respiratory waves (two computer generated and five patient trajectories) and scanned with a Philips Brilliance Big bore 16-slice CT simulator. 4DCT images were reconstructed using commercial amplitude- and phase-binning algorithms. Image quality of the amplitude- and phase-binned image sets was compared by evaluation of shape and volume distortions in reconstructed images. Clinical evaluations were performed on 64 4DCT patient image sets in a blinded review process. The amplitude- and phase-binned 4DCT maximum intensity projection (MIP) images were further evaluated for 28 stereotactic body radiation therapy (SBRT) cases of total 64 cases. A preliminary investigation of the effects of respiratory amplitude and pattern irregularities on motion artifact severity was conducted. Results: The phantom experiments illustrated that, as expected, maximum inhalation occurred at the 0% amplitude and maximum exhalation occurred at the 50% amplitude of the amplitude-binned 4DCT image sets. The phantom shape distortions were more severe in the images reconstructed from the phase-binning algorithm. In the clinical study, compared to the phase-binning algorithm, the amplitude-binning algorithm yielded fewer or less severe motion artifacts in 37.5% of the cases (24/64), comparable artifacts in 54.7% of the cases (35/64), and slightly greater artifacts in 7.8% of the cases (5/64). Evaluation of SBRT cases demonstrated that the reconstructed tumor sizes and locations were comparable in 96% (1/28) of the MIP image pairs generated from both amplitude- and phase-binning algorithms. In this case the amplitude-binned image set rendered a smaller tumor size, which was likely due to very shallow respiratory amplitudes occurring over several breathing cycles. Conclusions: Overall, the amplitude-binning algorithm for 4DCT reconstruction reduced the severity of tumor distortion and image artifacts compared to the phase-binning algorithm. However, the full range of motion may not be characterized using amplitude-binning algorithms. Despite superior performance, amplitude binning can still be susceptible to motion artifacts caused by large variations in amplitude of respiratory waves.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Iron oxyhydroxide mineralization on microbial extracellular polysaccharides

Iron biominerals can form in neutral pH microaerophilic environments where microbes both catalyze iron oxidation and create polymers that localize mineral precipitation. In order to classify the microbial polymers that influence FeOOH mineralogy, we studied the organic and mineral components of biominerals using scanning transmission X-ray microscopy (STXM), micro X-ray fluorescence ({mu}XRF) microscopy, and high-resolution transmission electron microscopy (HRTEM). We focused on iron microbial mat samples from a creek and abandoned mine; these samples are dominated by iron oxyhydroxide-coated structures with sheath, stalk, and filament morphologies. In addition, we characterized the mineralized products of an iron-oxidizing, stalk-forming bacterial culture isolated from the mine. In both natural and cultured samples, microbial polymers were found to be acidic polysaccharides with carboxyl functional groups, strongly spatially correlated with iron oxyhydroxide distribution patterns. Organic fibrils collect FeOOH and control its recrystallization, in some cases resulting in oriented crystals with high aspect ratios. The impact of polymers is particularly pronounced as the materials age. Synthesis experiments designed to mimic the biomineralization processes show that the polysaccharide carboxyl groups bind dissolved iron strongly but release it as mineralization proceeds. Our results suggest that carboxyl groups of acidic polysaccharides are produced by different microorganisms to create a wide range of iron oxyhydroxide biomineral structures. The intimate and potentially long-term association controls the crystal growth, phase, and reactivity of iron oxyhydroxide nanoparticles in natural systems.

54 ENVIRONMENTAL SCIENCES↗