RF Energy Harvesting Peel-and-Stick Sensors

PARC, a Xerox Company, is developing a low-cost system of peel-and-stick wireless sensors that will enable widespread building environment sensor deployment with the potential to deliver up to 30% energy savings. The system is embodied by a set of RF hubs that provide power to the automatically located sensor nodes, and relays data wirelessly to the building management system (BMS). The sensor nodes are flexible electronic labels powered by rectified RF energy transmitted by a RF hub and can contain multiple printed and conventional sensors. The system design overcomes limitations in wireless sensors related to power delivery, lifetime, and cost by eliminating batteries and photovoltaic devices. The sensor localization is performed automatically by the inclusion of a programmable multidirectional antenna array in the RF hub. Comparison of signal strengths when the RF beam is swept allows for sensor localization, further reducing installation effort and enabling automatic recommissioning of sensors that have been relocated, overcoming a significant challenge in building operations. PARC has already demonstrated wireless power and temperature data transmission up to a distance of 20m with a duty cycle less than a minute between measurements, using power levels well within the FCC regulation limits in the 902-928 MHz ISM band. The sensor’s RF energy harvesting antenna dimensions was less than 5cmx9cm, demonstrating the possibility of small form factor for the sensor nodes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PEEL-AND-STICK SENSORS POWERED BY DIRECTED RF ENERGY

PARC, a Xerox Company, is developing a low-cost system of peel-and-stick wireless sensors that will enable widespread building environment sensor deployment with the potential to deliver up to 30% energy savings. The system is embodied by a set of RF hubs that provide power to automatically located sensor nodes, and relay data wirelessly to the building management system (BMS). The sensor nodes are flexible electronic labels powered by rectified RF energy transmitted by an RF hub and can contain multiple printed and conventional sensors. The system design overcomes limitations in wireless sensors related to power delivery, lifetime, and cost by eliminating batteries and photovoltaic devices. Sensor localization is performed automatically by the inclusion of a programmable multidirectional antenna array in the RF hub. Comparison of signal strengths while the RF beam is swept allows for sensor localization, reducing installation effort and enabling automatic recommissioning of sensors that have been relocated, overcoming a significant challenge in building operations. PARC has already demonstrated wireless power and temperature data transmission up to a distance of 20m with less than one minute between measurements, using power levels well within the FCC regulation limits in the 902-928 MHz ISM band. The sensor’s RF energy harvesting antenna achieves high performance with dimensions below 5cm x 9cm.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ideal Integrating Bolometer

We describe a new 'ideal integrator' bolometer as a prototype for a new generation of sensitive, flexible far-IR detectors suitable for use in large arrays. The combination of a non-dissipative sensor coupled with a fast heat switch provides breakthrough capabilities in both sensitivity and operation. The bolometer temperature varies linearly with the integrated infrared power incident on the detector, and may be sampled intermittently without loss of information between samples. The sample speed and consequent dynamic range depend only on the heat switch reset cycle and can be selected in software. Between samples, the device acts as an ideal integrator with noise significantly lower than resistive bolometers. Since there is no loss of information between samples, the device is well-suited for large arrays. A single SQUID readout could process an entire column of detectors, greatly reducing the complexity, power requirements, and cost of readout electronics for large pixel arrays.

Kogut, Alan↗

Ideal Integrating Bolometer

We describe a new "ideal integrator" bolometer as a prototype for a new generation of sensitive, flexible far-IR detectors suitable for use in large arrays. The combination of a non-dissipative sensor coupled with a fast heat switch provides breakthrough capabilities in both sensitivity and operation. The bolometer temperature varies linearly with the integrated infrared power incident on the detector, and may be sampled intermittently without loss of information between samples. The sample speed and consequent dynamic range depend only on the heat switch reset cycle and can be selected in software. Between samples, the device acts as an ideal integrator with noise significantly lower than resistive bolometers. Since there is no loss of information between samples, the device is well-suited for large arrays. A single SQUID readout could process an entire column of detectors, greatly reducing the complexity, power requirements, and cost of readout electronics for large pixel arrays.

Kogut, A.↗

Sub-second and ppm-level optical sensing of hydrogen using templated control of nano-hydride geometry and composition

Abstract The use of hydrogen as a clean and renewable alternative to fossil fuels requires a suite of flammability mitigating technologies, particularly robust sensors for hydrogen leak detection and concentration monitoring. To this end, we have developed a class of lightweight optical hydrogen sensors based on a metasurface of Pd nano-patchy particle arrays, which fulfills the increasing requirements of a safe hydrogen fuel sensing system with no risk of sparking. The structure of the optical sensor is readily nano-engineered to yield extraordinarily rapid response to hydrogen gas (<3 s at 1 mbar H 2 ) with a high degree of accuracy (<5%). By incorporating 20% Ag, Au or Co, the sensing performances of the Pd-alloy sensor are significantly enhanced, especially for the Pd 80 Co 20 sensor whose optical response time at 1 mbar of H 2 is just ~0.85 s, while preserving the excellent accuracy (<2.5%), limit of detection (2.5 ppm), and robustness against aging, temperature, and interfering gases. The superior performance of our sensor places it among the fastest and most sensitive optical hydrogen sensors.

36 MATERIALS SCIENCE↗

Electrochemical Sensors Based on Nanomaterials for Environmental Monitoring

This article review work relevant to the two fastest growing nanomaterials in electrochemical sensing of metal ions: organically modified ordered mesoporous silicas (OMSs) and carbon nanotubes (CNTs). Nanostructured self-assembled monolayers on mesoporous silicas (SAMMS) materials are highly effective as electrode modifiers; they can be either mixed with conductive materials or spin-cast as a thin-film on electrode surface. The interfacial chemistry of SAMMS can be fine-tuned to selectively preconcentrate the specific metal ions of interest. The functional groups on SAMMS materials enable the preconcentration to be done without mercury, supporting electrolytes, applied potential, and solution degassing, all of which are often required in conventional adsorptive stripping voltammetric sensors. Since it was first introduced in 1991, CNTs have been widely investigated for electrochemical sensors of many important biomolecules because of their electrocatalytic and antifouling properties, biocompatibility, high surface, and mechanical strength. For trace metal analysis, CNT thin-film created by drop-coating of CNT-solvent suspensions on electrode surfaces has been explored in order to develop mercury-free sensors by exploiting the bulk properties of the CNTs. Array of low-site-density aligned carbon nanotubes has been grown on metal substrates by a non-lithographic method. Each CNT serves as a nanoelectrode which normally has greater mass transfer rate and higher mass sensitivity than conventional macroelectrodes. The array of millions of CNT nanoelectrodes provides magnified voltammetric signals for trace metal ions without the need for a signal amplifier.

Electrochemical Sensors↗

Automatic monitoring of vibration welding equipment

A vibration welding system includes vibration welding equipment having a welding horn and anvil, a host device, a check station, and a robot. The robot moves the horn and anvil via an arm to the check station. Sensors, e.g., temperature sensors, are positioned with respect to the welding equipment. Additional sensors are positioned with respect to the check station, including a pressure-sensitive array. The host device, which monitors a condition of the welding equipment, measures signals via the sensors positioned with respect to the welding equipment when the horn is actively forming a weld. The robot moves the horn and anvil to the check station, activates the check station sensors at the check station, and determines a condition of the welding equipment by processing the received signals. Acoustic, force, temperature, displacement, amplitude, and/or attitude/gyroscopic sensors may be used.

47 OTHER INSTRUMENTATION↗

Automated UF 6 Cylinder Enrichment Assay: Status of the Hybrid Enrichment Verification Array (HEVA) Project: POTAS Phase II

Pacific Northwest National Laboratory (PNNL) intends to automate the UF 6 cylinder nondestructive assay (NDA) verification currently performed by the International Atomic Energy Agency (IAEA) at enrichment plants. PNNL is proposing the installation of a portal monitor at a key measurement point to positively identify each cylinder, measure its mass and enrichment, store the data along with operator inputs in a secure database, and maintain continuity of knowledge on measured cylinders until inspector arrival. This report summarizes the status of the research and development of an enrichment assay methodology supporting the cylinder verification concept. The enrichment assay approach exploits a hybrid of two passively-detected ionizing-radiation signatures: the traditional enrichment meter signature (186-keV photon peak area) and a non-traditional signature, manifested in the high-energy (3 to 8 MeV) gamma-ray continuum, generated by neutron emission from UF 6 . PNNL has designed, fabricated, and field-tested several prototype assay sensor packages in an effort to demonstrate proof-of-principle for the hybrid assay approach, quantify the expected assay precision for various categories of cylinder contents, and assess the potential for unsupervised deployment of the technology in a portal-monitor form factor. We refer to recent sensor-package prototypes as the Hybrid Enrichment Verification Array (HEVA). The report provides an overview of the assay signatures and summarizes the results of several HEVA field measurement campaigns on populations of Type 30B UF 6 cylinders containing low-enriched uranium (LEU), natural uranium (NU), and depleted uranium (DU). Approaches to performance optimization of the assay technique via radiation transport modeling are briefly described, as are spectroscopic and data-analysis algorithms.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Silicon on-chip bandpass filters for the multiplexing of high sensitivity photonic crystal microcavity biosensors

A method for the dense integration of high sensitivity photonic crystal (PC) waveguide based biosensors is proposed and experimentally demonstrated on a silicon platform. By connecting an additional PC waveguide filter to a PC microcavity sensor in series, a transmission passband is created, containing the resonances of the PC microcavity for sensing purpose. With proper engineering of the passband, multiple high sensitivity PC microcavity sensors can be integrated into microarrays and be interrogated simultaneously between a single input and a single output port. The concept was demonstrated with a 2-channel L55 PC biosensor array containing PC waveguide filters. The experiment showed that the sensors on both channels can be monitored simultaneously from a single output spectrum. Less than 3 dB extra loss for the additional PC waveguide filter is observed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of the QWIP Focal Plane Arrays for NASA's Landsat Data Continuity Mission

The focal plane assembly for the Thermal Infrared Sensor (TIRS) instrument on NASA's Landsat Data Continuity Mission (LDCM) consists of three 512 x 640 GaAs Quantum Well Infrared Photodetector (QWIP) arrays. The three arrays are precisely mounted and aligned on a silicon carrier substrate to provide a continuous viewing swath of 1850 pixels in two spectral bands defined by filters placed in close proximity to the detector surfaces. The QWIP arrays are hybridized to Indigo ISC9803 readout integrated circuits (ROICs). QWIP arrays were evaluated from four laboratories; QmagiQ, (Nashua, NH), Army Research Laboratory, (Adelphi, MD}, NASA/ Goddard Space Flight Center, (Greenbelt, MD) and Thales, (Palaiseau, France). All were found to be suitable. The final discriminating parameter was the spectral uniformity of individual pixels relative to each other. The performance of the QWIP arrays and the fully assembled, NASA flight-qualified, focal plane assembly will be reviewed. An overview of the focal plane assembly including the construction and test requirements of the focal plane will also be described.

Jhabvala, M.↗

Molecular modeling of polymer composite-analyte interactions in electronic nose sensors

We report a molecular modeling study to investigate the polymer-carbon black (CB) composite-analyte interactions in resistive sensors. These sensors comprise the JPL electronic nose (ENose) sensing array developed for monitoring breathing air in human habitats. The polymer in the composite is modeled based on its stereoisomerism and sequence isomerism, while the CB is modeled as uncharged naphthalene rings with no hydrogens. The Dreiding 2.21 force field is used for the polymer, solvent molecules and graphite parameters are assigned to the carbon black atoms. A combination of molecular mechanics (MM) and molecular dynamics (NPT-MD and NVT-MD) techniques are used to obtain the equilibrium composite structure by inserting naphthalene rings in the polymer matrix. Polymers considered for this work include poly(4-vinylphenol), polyethylene oxide, and ethyl cellulose. Analytes studied are representative of both inorganic and organic compounds. The results are analyzed for the composite microstructure by calculating the radial distribution profiles as well as for the sensor response by predicting the interaction energies of the analytes with the composites. c2003 Elsevier Science B.V. All rights reserved.

NASA Center JPL↗

Instrumentation and Control Selection for the 12 GeV Hall-B Magnets at Jefferson Lab

Here, as part of the Jefferson Lab 12 GeV accelerator upgrade, the Experimental Physics Hall B detector system requires two superconducting magnets – a Torus and a Solenoid. The specifications required maximum space for the detectors which led to the choice of conduction cooling for each magnet. The Torus consists of 6 trapezoidal 'race-track'-type coils connected in series with an operating current of 3770 A. The Solenoid is an actively shielded 5 Tesla magnet consisting of 5 coils connected in series operating at 2416 A. Within the hall the two magnets are located in close proximity to each other and are surrounded by particle detectors. We describe the philosophy behind the instrumentation selection and control design that accounts for this proximity and other challenging working conditions. We describe the choice of sensor technologies, as well as the control and data acquisition methods. The magnet power and cryogenic control sub-systems are implemented using Allen Bradley Control Logix 1756-L72 Programmable Logic Controllers. Sensor instrumentation read-backs are routed into the PLC via National Instruments cRIO hardware (Field Programmable Gate Arrays or FPGA/RT application) using Jefferson Lab designed FPGA-based multi-sensor-excitation-chassis. Configuration, monitoring, and alarm handlers for the magnet systems are provided via an Experimental Physics Instrumentation & Control System interface (EPICS). Failure Modes and Effects Analysis (FMEA) and the requirement to monitor critical parameters during operation guided the selection of instrumentation and associated hardware. The design of the quench protection and voltage tap sub-systems was driven by the anticipated level of voltages developed during a magnet quench. The primary hard-wired quench detection and protection sub-system together with the secondary PLC-based protection sub-system is also discussed. The successful commissioning and subsequent performance of these magnets demonstrates the robustness of the design and implementation approach that was adopted by the Jefferson Lab team and serves as an excellent 'How To' guide for future projects of this size and complexity.

12 GeV↗

High Spectral Resolution, High Cadence, Imaging X-Ray Microcalorimeters for Solar Physics

High spectral resolution, high cadence, imaging x-ray spectroscopy has the potential to revolutionize the study of the solar corona. To that end we have been developing transition-edge-sensor (TES) based x-ray micro calorimeter arrays for future solar physics missions where imaging and high energy resolution spectroscopy will enable previously impossible studies of the dynamics and energetics of the solar corona. The characteristics of these x-ray microcalorimeters are significantly different from conventional micro calorimeters developed for astrophysics because they need to accommodate much higher count rates (300-1000 cps) while maintaining high energy resolution of less than 4 eV FWHM in the X-ray energy band of 0.2-10 keV. The other main difference is a smaller pixel size (less than 75 x 75 square microns) than is typical for x-ray micro calorimeters in order to provide angular resolution less than 1 arcsecond. We have achieved at energy resolution of 2.15 eV at 6 keV in a pixel with a 12 x 12 square micron TES sensor and 34 x 34 x 9.1 micron gold absorber, and a resolution of 2.30 eV at 6 keV in a pixel with a 35 x 35 micron TES and a 57 x 57 x 9.1 micron gold absorber. This performance has been achieved in pixels that are fabricated directly onto solid substrates, ie. they are not supported by silicon nitride membranes. We present the results from these detectors, the expected performance at high count-rates, and prospects for the use of this technology for future Solar missions.

Bandler, Simon R.↗

Molecular modeling of polymer composite interactions with analytes in electronic nose sensors for environmental monitoring in International Space Station

We report a molecular modeling study to investigate the polymer-carbon black (CB) composite-analyte interactions in resistive sensors. These sensors comprise the JPL Electronic Nose (ENose) sensing array developed for monitoring breathing air in human habitats. The polymer in the composite is modeled based on its stereisomerism and sequence isomerism, while the CB is modeled as uncharged naphthalene rings (with no hydrogens). The Dreiding 2.21 force field is used for the polymer and solvent molecules and graphite parameters are assigned to the carbon black atoms. A combination of molecular mechanics (MM) and molecular dynamics (NPT-MD and NVT-MD) techniques are used to obtain the equilibrium composite structure by inserting naphthalene rings in the polymer matrix. Polymers considered for this work include poly(4- vinylphenol), polyethylene oxide, and ethyl cellulose. Analytes studied are representative of both inorganic (ammonia) and organic (methanol, toluene, hydrazine) compounds. The results are analyzed for the composite microstructure by calculating the radial distribution profiles as well as for the sensor response by predicting the interaction energies of the analytes with the composites.

electronic noise environmental monitoring polymer ↗

Characterization of Slat Noise Radiation from a High-Lift Common Research Model

A test campaign was conducted in the open-jet test section of the NASA Langley 14- by 22-Foot Subsonic Tunnel on a 10%-scale, semispan version of a High-Lift Common Research Model (CRM-HL) incorporating a leading-edge slat, trailing-edge flap and removable high-fidelity main landing gear. Aerodynamic and far field acoustic measurements were obtained on baseline and acoustically treated model configurations using an ensemble of time-averaged and unsteady surface pressure sensors paired with a traversing 97-microphone phased array viewing the pressure side of the airframe. A modified version of the DAMAS deconvolution method incorporating corrections for shear layer acoustic wave decorrelation was employed to determine the locations and strengths of relevant noise sources along the span of the slat and in the vicinity of the flap edges and landing gear. The main goal of the test campaign was to use the surface pressure and array data to evaluate the effectiveness of various slat noise reduction concepts. It was found that slat-gap fillers produced significant broadband noise reduction with minimal aerodynamic performance penalties for all Mach numbers and airfoil angles of attack that were investigated. The test campaign clearly demonstrated the noise reduction benefits that can be obtained by applying appropriate treatments to leading-edge slats on commercial transport-class aircraft.

Aeronautics Research Mission Directorate↗

Development of Large-Scale Magnetic Calorimeter Arrays

We describe performance of large-scale arrays of metallic magnetic calorimeters (MMCs) we are developing to meet requirements of the Lynx X-ray Microcalorimeter (LXM) instrument in the astrophysics mission concept Lynx. We have fabricated prototypes with 55,800 x-ray pixels thermally connected to 5,688 MMC sensors. Subarrays demonstrate three types of pixels, which have different energy and spatial resolution goals in LXM. Pixel pitch is 50 or 25 µm. For two subarrays, use of position sensitive detectors, in a "hydra" configuration with 25 x-ray absorbers per sensor, helps achieve a large focal plane by increasing pixel count relative to readout channels. Since each absorber has a different thermal link to its sensor, it generates a different pulse shape and enables discrimination of pixel position. Superconducting wiring from all sensors was brought out to the perimeter of the overall array using multiple buried metal layers planarized by Chemical Mechanical Planarization to achieve high critical current, low inductance, and high fabrication yield. An automated, algorithmic approach was used to layout the complex wiring pattern. For readout with existing small arrays of Superconducting Quantum Interference (SQUID) amplifiers, 112 selected pixels were connected to wire bond pads. In hydras, we successfully identified 25 pulse shapes using rise-time and pulse height. Pulse shapes were similar to simulations. We measured noise and responsivity to substrate temperature and applied x-ray pulses. While we designed sensors to have high inductance to relative to stray inductance of wiring, we had only mismatched (lower input inductance) SQUIDs available in our current apparatus, giving non-optimized resolution. We compared measured and calculated energy resolutions. We have the required sensitivity to reach < 3 eV FWHM resolution for 6 keV x-rays, required for the LXM Main Array, and the ability to discriminate the 25 different absorber pixels down to energies < 300 eV.

microcalorimeters↗

Subtask 1.4 - Techno-Economic Assessment of Regional Carbon Utilization Scenarios and Attendant Monitoring Technology

The U.S. Department of Energy (DOE) Carbon Storage Program seeks to develop technologies to significantly improve the effectiveness of carbon capture and storage (CCS), reduce the cost of implementation, and support the readiness of widespread commercial deployment by 2035. To accomplish this goal, technical and economic barriers must be addressed and the results used to inform regulators and industry on the safety, permanence, and viability of carbon storage. To help overcome these barriers, the Energy & Environmental Research Center (EERC) conducted three activities: 1) investigate the regional techno-economic life cycle of CO2 enhanced oil recovery (EOR) in North Dakota, 2) assist DOE in determining the prospective CO2 storage resource of residual oil zones (ROZs), and 3) develop a seismic technique for monitoring geologic storage of CO2. These three activities address two strategic goals enumerated in the DOE–EERC Cooperative Agreement, namely, 1) to advance foundational science and 2) to inform data-driven policies that enhance U.S. economic growth and job creation, energy security, and environmental quality. Activity 1 In North Dakota, there is synergistic incentive to develop and implement CO2 EOR technologies. Regional industry partners are actively seeking options that can cost-effectively improve the efficiency of power production, while also coproducing CO2 for use in EOR applications. A full-value-chain techno-economic assessment that links lignite resources, power generation, and EOR is needed to determine the implications for a state or region to continue to use these resources or look elsewhere for other energy sources and revenue streams. The integration of North Dakota’s lignite power industry with the state’s oil industry has the potential to revitalize legacy oil fields and produce up to 1 billion barrels of additional oil using CO2 EOR while providing a market for a CO2 commodity captured at coal-fired power plants. Revitalization of North Dakota’s legacy oil fields will bring new industry investment to the state, resulting in the growth of oil-related jobs and revenue through oil sales, severance tax, and associated oilfield development activities (drilling, pipelines, etc.). CO2 demand for EOR and incremental oil production were calculated for 201 conventional oil fields in North Dakota. Infrastructure development in the fields was estimated using 1) a traditional vertical well arrangement of CO2 injectors and oil producers and 2) an advanced case where horizontal wells were used exclusively. Pipeline, compression, and recycling infrastructure requirements were also estimated. When viewed from the CO2 capture and CO2 EOR sectors, the advanced case showed a positive investment scenario when including potential benefits of the 45Q tax credit policy. An economic evaluation of a full implementation of CO2 EOR showed an average $60 billion potential state economic impact estimated over the 37-year construction and production time frame could be realized with an assumed oil price of $65/bbl. Oil price ranges of $35–$90/bbl cause an estimated variation of ±$5 billion over the potential effort. The total net state government revenues were estimated over the 37-year construction and production time frame. With an assumed oil price of $65/bbl, total potential fiscal impact could average $7.4 billion. This result ranges about ±$2.5 billion for a potential EOR implementation effort for oil price ranges of $35–$90/bbl. This broad-brush assessment was focused on “magnitude-of-effect” perspectives of what CO2 capture and use for EOR could mean to the state. Whether CO2 EOR ever becomes widely adopted is not the issue at this stage of evaluation. The question being answered is, How valuable could CO2 capture and CO2 EOR be for the state and local jurisdictions in western North Dakota? The results of the current economic assessment remove any ambiguity to that question. Full implementation of CO2 EOR as modeled in this study provides substantial economic benefits to the state, even at low oil prices (i.e., $35/bbl). Job creation and government revenues could be substantial, depending on the scale of implementation. With a better understanding of what CO2 EOR might mean for the state’s economy, the focus can now shift to the policies and financial mechanisms needed to make private investment in CO2 capture and use as EOR competitive with other energy-related pursuits. Activity 2 ROZs contain remnants of oil not swept away by natural waterflooding. Although nearly all of the identified ROZs are found in West Texas, there is evidence that this category of oil reservoir can be found in other major oil-producing basins of the United States. Because the formation of these oil reservoirs is distinct from other conventional reservoirs, the method to estimate the prospective CO2 storage resource in ROZs may be equally distinct from the method used for conventional fields. As such, the EERC collaborated with DOE’s National Energy Technology Laboratory (NETL) to investigate the feasibility of CO2 storage in ROZs and determine what specific modification (if any) needs to be made to the current DOE volumetric method to estimate prospective CO2 storage resource in oil reservoirs. This activity built on a previous EERC investigation to identify ROZs in the Williston and Powder River Basins and upon collaborations between the EERC and NETL to develop storage resource estimation methods for different types of geologic CO2 storage. Review of the volumetric approach raised questions about the applicability of such an approach to hydrocarbon-bearing zones without the inclusion of potential hydrocarbon production. A production-based approach was presented by the EERC to inform the working group of additional methods of increasing the CO2 storage resource potential. Because the production-based method focuses more heavily on oil recovery than CO2 storage, it was not included in the working group manuscript. Activity 3 The EERC has used sparse and irregular seismic arrays to detect CO2 injected into a reservoir. The variability of seismic noise recorded by the sensors directly impacts the seismic interpretation. However, designing noise attenuation workflows effectively can be a more challenging task using sparse and irregular arrays for data acquisition. Based on the hypothesis that noncoherent noise is stationary during weekly data acquisition, a new machine-learning algorithm was developed to automatically estimate noise conditions using passive records, noise from active records, and ancillary information. The new noise attenuation processing workflow can improve the time-lapse detection of CO2 from sparse and irregular array acquisitions. Results show spatial and temporal noise patterns can be related to the location of the sensors and the weather conditions during the data acquisition and that our attenuation processing workflow can improve the time-lapse detection of CO2 from sparse and irregular array acquisitions. This effort was funded in part through the EERC–DOE Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Department of Commerce.

Peck, Wesly↗