Search NASA⌕ Search

SEARCH · Search NASA

Results for “source injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Electron string ion sources for carbon ion cancer therapy accelerators

The type of the Electron String Ion Sources (ESIS) is considered to be the appropriate one to produce pulsed C{sup 4+} and C{sup 6+} ion beams for cancer therapy accelerators. In fact, the new test ESIS Krion-6T already now provides more than 10{sup 10} C{sup 4+} ions per pulse and about 5 × 10{sup 9} C{sup 6+} ions per pulse. Such ion sources could be suitable to apply at synchrotrons. It has also been found that Krion-6T can provide more than 10{sup 11} C{sup 6+} ions per second at the 100 Hz repetition rate, and the repetition rate can be increased at the same or larger ion output per second. This makes ESIS applicable at cyclotrons as well. ESIS can be also a suitable type of ion source to produce the {sup 11}C radioactive ion beams. A specialized cryogenic cell was experimentally tested at the Krion-2M ESIS for pulse injection of gaseous species into the electron string. It has been shown in experiments with stable methane that the total conversion efficiency of methane molecules to C{sup 4+} ions reached 5%÷10%. For cancer therapy with simultaneous irradiation and precise dose control (positron emission tomography) by means of {sup 11}C, transporting to the tumor with the primary accelerated {sup 11}C{sup 4+} beam, this efficiency is preliminarily considered to be large enough to produce the {sup 11}C{sup 4+} beam from radioactive methane and to inject this beam into synchrotrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AFR-100 Sodium-CO 2 Reaction Analysis

Pressure-boundary failure within the heat-source heat exchanger (IHTS-fluid to secondary-fluid heat exchanger) in a sodium-cooled reactor will lead to a violent decompression on the secondary side and large pressure transients in the IHTS. If the secondary fluid is water or CO 2 , the pressure transients will be intensified by an energetic reaction between the sodium & water or sodium & CO 2 . The coupling of secondary-fluid injection, reaction dynamics, product gas bubble growth, and sodium system response results in a succession of short duration, high intensity pressure pulses travelling in the heat-source heat exchanger and IHTS. Each pulse has higher amplitude than the preceding one if no mitigating features such as rupture disks and gas spaces are provided in the system design. Pressure pulse absorption features and relief systems must be included in the IHTS design to prevent structural damage to the heat-source heat exchanger, and IHTS piping. In the case of the AFR-100 design, the boundary between the IHTS sodium and the secondary-side CO 2 within the sodium-CO 2 heat exchanger could potentially fail. The resulting fluid-hammer and sodium-CO 2 reaction must be mitigated. A variety of heat exchangers types have been proposed for the sodium-CO 2 side. Thus, the following analysis of the IHTS response to a sodium-CO 2 reaction includes a wide range of potential break sizes to cover this spectrum of heat exchanger types. The IHTS pressure response due to leak sizes ranging from 2.0 mm – 16.1 mm were evaluated. Double-ended guillotine tube breaks at the top, center, and bottom of the tube bundle were also considered. As expected, the peak reaction bubble pressure increased and rupture disk burst time decreased as the break size increased. As currently designed, all components, including the sodium-CO 2 heat exchanger tubes and shell and the IHX tubes, can withstand the maximum pressures calculated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Motion of 3-6 keV Nonthermal Sources Along the Legs of a Flare Loop

Observations of nonthermal X-ray sources me critical to studying electron acceleration and transport in solar flares. Strong thermal emission radiated from the preheated plasma before the flare impulsive phase often makes it difficult to detect low-energy X-ray sources that are produced by relatively low-energy nonthermal electrons. Knowledge of the distribution of these low-energy nonthermal electrons is particularly important in determining the total nonthermal electron energy in solar flares. We report on an 'early impulsive flare' in which impulsive hard X-ray emission was seen early in the flare before the soft X-ray emission had risen significantly, indicating limited plasma pre-heating. Early in the flare, RHESSI < 25 keV images show coronal sources that moved first downward and then upwards along the legs of a flare loop. In particular, the 3-6 keV source appeared as a single coronal source at the start of the flare, and then it involved into two coronal sources moving down along the two legs of the loop. After nearly reaching the two footpoints at the hard X-ray peak, the two sources moved back up to the looptop again. RHESSI images and light curves all indicate that nonthermal emission dominated at energies as low as 3-6 keV. We suggest that the evolution of both the spectral index and the low-energy cutoff of the injected electron distribution could result in the accelerated electrons reaching a lower altitude along the legs of the dense flare loop and hence result in the observed downward and upward motions of the nonthermal sources.

Sui, Linhui↗

The MIST-1 and MIST-2 multicusp ion sources for high-current $H$$^{+}_{2}$ beams

We present two iterations of the Multicusp Ion Source Technology at MIT (MIST) sources, designed to fulfill the requirements of the HCHC-XX cyclotron design. The HCHC-XX is a novel compact cyclotron accelerating $H$$^{+}_{2}$. Beam is injected through a radio-frequency quadrupole buncher-accelerator (embedded in the cyclotron yoke) and utilizes so-called vortex motion during acceleration. If successful, it will deliver 10 mA of protons at 60 MeV in CW mode. This scheme requires a low-emittance, high-current initial beam with high $H$$^{+}_{2}$ purity. We briefly summarize the design and previous results of the MIST-1 ion source and, for the first time, the detailed design of the new and improved MIST-2, including the mechanical, electrical, and control system design. We further show experimental results of using the MIST-2 backplate on the MIST-1 body, present a study using different types of permanent magnets for confinement (including no magnets), and finally, we present first results of the MIST-2 in full operation. In this first commissioning run, we were able to increase the total extracted current from the MIST-2 to 7 mA—a factor of 2 over the MIST-1.

Winklehner, D. [Massachusetts Institute of Technol↗

NIO1 diagnostics

The radio frequency ion source NIO1, jointly developed by Consorzio RFX and INFN-LNL, will generate a 60kV-135mA hydrogen negative ion beam, composed of 9 beamlets over an area of about 40 × 40 mm{sup 2}. This experiment will operate in continuous mode and in conditions similar to those foreseen for the larger ion sources of the Neutral Beam Injectors for ITER. The modular design of NIO1 is convenient to address the several still open important issues related to beam extraction, optics, and performance optimization. To this purpose a set of diagnostics is being implemented. Electric and water cooling plant related measurements will allow monitoring current, pressure, flow, and temperature. The plasma in the source will be characterized by emission spectroscopy, cavity ring-down and laser absorption spectroscopy. The accelerated beam will be analyzed with a fast emittance scanner, its intensity profile and divergence with beam emission spectroscopy and visible tomography. The power distribution of the beam on the calorimeter will be monitored by thermocouples and by an infrared camera. This contribution presents the implementation and initial operation of some of these diagnostics in the commissioning phase of the experiment, in particular the cooling water calorimetry and emission spectroscopy.

43 PARTICLE ACCELERATORS↗

Recent Plasma Observations Related to Magnetic Merging and the Low-Latitude Boundary Layer. Case Study by Polar, March 18, 2006

We have begun an investigation of the nature of the low-latitude boundary layer in the mid-altitude cusp region using data from the Polar spacecraft. Magnetosheath-like plasma is frequently observed deep (in terms of distance from the magnetopause and in invariant latitude) in the magnetosphere. One such case, taken during a long period of northward interplanetary magnetic field (IMP) on March 18, 2006, shows injected magnetosheath ions within the magnetosphere with velocity distributions resulting from two separate merging sites along the same field lines. Cold ionospheric ions were also observed counterstreaming along the field lines, evidence that these field lines were closed. Our results support the idea of double reconnection under northward IMP on the same group of field lines can provide a source for the LLBL. However, the flow direction of the accelerated magnetosheath ions antiparallel to the local magnetic field and given location of the spacecraft suggest that these two injection sites are located northward of the spacecraft position. Observed convection velocities of the magnetic field lines are inconsistent with those expected for double post-cusp reconnection in both hemispheres. These observations favor a scenario in which a group of newly closed field lines was created by a combination of high shear merging at high latitudes in the northern hemisphere and low shear merging at lower latitudes at the dayside magnetopause.

Chandler, M.↗

Assessment of geophysical monitoring methods for detection of brine and CO 2 leakage in drinking water aquifers

Here, we evaluated and compared the effectiveness of four surface-based geophysical monitoring methods to downhole pressure and chemical methods to detect brine and CO 2 leakage in underground sources of drinking water overlying a CO 2 storage reservoir. This assessment uses synthetic monitoring data generated from 400 simulated aquifer impact data sets. Here, the six monitoring techniques can detect impacted groundwater once 20,000 tonnes of CO 2 have leaked into the drinking water resource. Geophysical methods are most effective at detecting shallow plumes. Although downhole monitoring methods outperform geophysical methods in detecting deep plumes, geophysical methods may help reduce the false negative during the post injection site care because they detect impacted groundwater where downhole sensors may be absent.

58 GEOSCIENCES↗

Radiation Safety System for SPIDER Neutral Beam Accelerator

SPIDER (Source for Production of Ion of Deuterium Extracted from RF Plasma only) and MITICA (Megavolt ITER Injector Concept Advanced) are the ITER neutral beam injector (NBI) testing facilities of the PRIMA (Padova Research Injector Megavolt Accelerated) Center. Both injectors accelerate negative deuterium ions with a maximum energy of 1 MeV for MITICA and 100 keV for SPIDER with a maximum beam current of 40 A for both experiments. The SPIDER facility is classified in Italy as a particle accelerator. At present, the design of the radiation safety system for the facility has been completed and the relevant reports have been presented to the Italian regulatory authorities. Before SPIDER can operate, approval must be obtained from the Italian Regulatory Authority Board (IRAB) following a detailed licensing process. In the present work, the main project information and criteria for the SPIDER injector source are reported together with the analysis of hypothetical accidental situations and safety issues considerations. Neutron and photon nuclear analysis is presented, along with special shielding solutions designed to meet Italian regulatory dose limits. The contribution of activated corrosion products (ACP) to external exposure of workers has also been assessed. Nuclear analysis indicates that the photon contribution to worker external exposure is negligible, and the neutron dose can be considered by far the main radiation protection issue. Our results confirm that the injector has no important radiological impact on the population living around the facility.

43 PARTICLE ACCELERATORS↗

Characterization of Chemical Sputtering Using the Mark II DIMES Porous Plug Injector in Attached and Semi-detached Divertor Plasmas of DIII-D

An improved, self-contained gas injection system for the divertor material evaluation system (DIMES) on DIII-D has been employed for in situ study of chemical erosion in the tokamak divertor environment. To minimize perturbation to local plasma, the Mark II porous plug injector (PPI) releases methane through a porous graphite surface at the outer strike point at a rate precisely controlled by a micro-orifice flow restrictor to be approximately equal as that predicted for intrinsic chemical sputtering. Effective photon efficiencies resulting from CH(4) are found to be 58 +/- 12 in an attached divertor (n(e) similar to 1.5 x 10(13)/cm(3), T(e) similar to 25 eV, T(surf)similar to 450 K), and 94 +/- 20 in a semi-detached cold divertor (n(e) similar to 6.0 x 10(13)/cm(3), T(e) similar to 2-3 eV, T(surf) similar to 350 K). These values are significantly more than previous measurements in similar plasma conditions, indicating the importance of the injection rate and local re-erosion for the integrity of this analysis. The contribution of chemical versus physical sputtering to the source of C(+) at the target is assessed through simultaneous measurement of CII line, and CD plus CH-band emissions during release of CH(4) from the Pill, then compared with that seen in intrinsic sputtering. (C) 2009 Elsevier B.V. All rights reserved.

03 NATURAL GAS↗

Coherent ultra-broadband laser-assisted injection radiation from a laser plasma accelerator

The injection of electrons into a laser wakefield accelerator (LWFA) is observed to generate an intense coherent ultra-broadband and ultrashort pulse radiation flash, consistent with the acceleration of electrons from rest to nearly the speed of light in a distance <~1μm. Under certain conditions, the radiation occurs at harmonics of the local plasma frequency. The flash is sufficiently bright to induce large nonlinear refractive index shifts in optical materials; we estimate a source brightness temperature of ~10 18 K. We present measurements of the flash spectra, coherence, pulse duration, polarization, and angular distribution, providing a detailed picture of electron injection dynamics in LWFA. Furthermore, these are characteristic of laser-assisted injection of off-axis electrons, which preserves wake coherence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feasibility of a Deep Direct-Use Geothermal System at the University of Illinois Urbana-Champaign

This study assesses the feasibility of using deep direct-use (DDU) geothermal energy in agricultural research facilities on the University of Illinois at Urbana-Champaign campus to exploit low-temperature sedimentary basins, such as the Illinois Basin. Subsurface components of the system include extraction and injection wells and downhole pumps. Surface equipment includes heat pumps/exchangers, and fluid transport and monitoring systems. Two geologic formations in the region exhibit a potential as sources for geothermal energy, based on pre initial temperatures and flow rates of fluids. The St. Peter and Mt. Simon Sandstones lie at depths of 634 and 1,280 m, respectively. Geocellular modeling is used to characterize the reservoirs. A St. Peter Sandstone model was made for an area south of the campus. Petrophysical and geothermal properties used are based on data from the closest wells penetrating the formations. Characterization of the Mt. Simon Sandstone is in progress and is not discussed here. Extraction and injection flows simulated with different wellbore configurations provide estimates of fluid flow out of and into the reservoir. The models are used to optimize flow rates, bottomhole pressure, and temperature of the produced fluid. Individual wellbore models simulate subsurface heat loss and gain, providing guidance on the optimal type and amount of insulation in the wellbore. Design of the surface facilities will address aspects of fluid delivery, heat exchange, capital operating costs, heat loss, and corrosion. Heat capacity and flow rates are assessed to estimate life-cycle costs and benefits, including the environmental benefits of reducing greenhouse gases and water use and increased energy efficiency. A preliminary analysis of surface configurations for the DDU system (including cascading applications) based on building heat loads is being conducted to identify multiple system designs that will maximize performance, energy efficiency, and cost recovery.

15 GEOTHERMAL ENERGY↗

A Unified Beam-Dynamics and Hardware Design Framework for Hybrid Nonlinear-Kicker Injection in NSLS-II

Nonlinear kickers (NLKs) enable off-axis injection in ultralow-emittance storage rings by providing a strong kick to the injected beam while remaining nearly transparent to the stored beam. In hybrid schemes, a conventional four-kicker bump defines the injected trajectory, and the NLK reduces the first-turn action under constrained beam offset and optics conditions. Effective operation additionally requires stable and reproducible first-turn injection trajectories. We develop a compact action–angle framework that expresses NLK dynamics in terms of Courant–Snyder invariants and yields an analytical bound on achievable action reduction. This formulation provides direct design rules for NLK placement, phase advance, injected-beam offset, and kicker field profile. Within this framework, we identify the 8-wire NLK as a practical baseline and extend its design by relaxing the square-geometry constraint, enabling inward shifting of the off-axis field peak while preserving on-axis field and gradient cancellation. Application to the NSLS-II lattice shows how aperture, pulsed-power, and mechanical constraints combine to determine a coupled design solution. Multi-turn tracking confirms that candidate NLK locations maintain sufficient stay-clear (aperture-clearance) margin, while the optimized wire geometry reduces the required current and Lorentz force load. The results establish a unified approach for NLK-assisted injection design and provide a practical pathway for upgrades in diffraction-limited storage rings.

36 MATERIALS SCIENCE↗

Continuous Flow Liquid Microjunction Surface Sampling Probe Connected On-line with HPLC/MS for Spatially Resolved Analysis of Small Molecules and Proteins

RATIONALE: A continuous flow liquid microjunction surface sampling probe extracts soluble material from surfaces for direct ionization and detection by MS. Demonstrated here is the on-line coupling of such a probe with HPLC/MS enabling extraction, separation and detection of small molecules and proteins from surfaces in a spatially resolved (~0.5 mm diameter spots) manner. Methods: A continuous flow liquid microjunction surface sampling probe was connected to a 6-port, 2-position valve for extract collection and injection to an HPLC column. A QTRAP 5500 hybrid triple quadrupole linear ion trap equipped with a Turbo V ion source operated in positive ESI mode was used for all experiments. System operation was tested with extraction, separation and detection of propranolol and associated metabolites from drug dosed tissues and proteins from dried sheep blood spots on paper. Results: Confirmed in the tissue were the parent drug and two different hydroxypropranolol glucuronides. The mass spectrometric response for these compounds from different locations in the liver showed an increase with increasing extraction time (5, 20 and 40 s extractions). For on-line separation and detection/identification of extracted proteins from dried sheep blood spots, two major protein peaks dominated the chromatogram and could be correlated with the expected masses for the hemoglobin and chains. Conclusions: Spatially resolved sampling, separation, and detection of small molecules and proteins from surfaces can be accomplished using a continuous flow liquid microjunction surface sampling probe coupled on-line with HPLC/MS detection.

dried blood spots↗

Characterization of Non-uniformities in Superconducting Tunnel Junction Radiation Detectors

The small dimensions of superconducting tunnel junction (STJ) radiation detectors have motivated the development of STJ arrays to increase detection efficiency and statistical accuracy. We have used a pulsed UV laser and X-rays to characterize and understand non-uniformities in the response of different pixels in Ta-based STJ arrays. To separate the contributions of the detector and the readout electronics, we have also injected the pulses from an arbitrary waveform generator into the array’s amplifier chain. We discuss the magnitude and the sources of the non-uniformity and approaches to reduce it.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The role of wellbore remediation on the evolution of groundwater quality from CO₂ and brine leakage

Long-term storage of CO₂ in underground reservoirs requires a careful assessment to evaluate risk to groundwater sources. The focus of this study is to assess time-frames required to restore water quality to pre-injection levels based on output from complex reactive transport simulations that exhibit plume retraction within a 200-year simulation period. We examined the relationship between plume volume, cumulative injected CO₂ mass, and permeability. The role of mitigation was assessed by projecting falloffs in plume volumes from their maximum peak levels with a Gaussian function to estimate plume recovery times to reach post-injection groundwater compositions. The results show a strong correlation between cumulative injected CO₂ mass and maximum plume pH volumes and a positive correlation between CO₂ flux, cumulative injected CO₂, and plume recovery times, with secondary dependence on permeability.

54 ENVIRONMENTAL SCIENCES↗

Experimental studies of the arc chamber short circuit failure mechanism on the DIII-D neutral beam system

Here we report on efforts to improve performance and longevity of the Neutral Beam Injection (NBI) system by initiating a R&D program aimed at studying the most common failure mechanism for the ion sources. To this end a filament driven plasma chamber has been constructed with plasma parameters similar to the arc chamber of NBI ion sources. A preliminary report of an investigation into the most common failure is presented here: The failure mechanism observed during helium operations on DIII-D is the result of electrical breakdown of the insulation material that separates the filament plates from the anode. The fault is reproduced in a table top experiment analogous to the DIII-D NBI ion source in key parameters and proposals for amelioration of the issue are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Off-line commissioning of the St. Benedict radiofrequency quadrupole cooler-buncher

The St. Benedict ion trapping system, which aims to measure the β - v angular correlation parameter in superallowed-mixed mirror transitions, is under construction at the University of Notre Dame. These measurements will provide much-needed data to improve the accuracy of the V ud element of the CKM matrix. One of the major components of this system is the radio frequency quadrupole cooler-buncher, which is necessary to create low-emittance ion bunches for injection into the measurement Paul trap. The off-line commissioning of the cooler-buncher, using a potassium ion source, determined that the device could produce cooled ion bunches characterized by a 50-ns full-width-half-maximum time width at its exit. The commissioning results also determined the trapping efficiency to be 93(1)% and the trapping half-life to be 20.0(5) s.

Paul trap↗

Optical activation and detection of charge transport between individual colour centres in diamond

Understanding the capture of charge carriers by colour centres in semiconductors is important for the development of novel forms of sensing and quantum information processing, but experiments typically involve ensemble measurements, often impacted by defect proximity. In this study, we show that confocal fluorescence microscopy and magnetic resonance can be used to induce and probe charge transport between individual nitrogen-vacancy centres in diamond at room temperature. In our experiments, a ‘source’ nitrogen vacancy undergoes optically driven cycles of ionization and recombination to produce a stream of photogenerated carriers, one of which is subsequently captured by a ‘target’ nitrogen vacancy several micrometres away. We use a spin-to-charge conversion scheme to encode the spin state of the source colour centre into the charge state of the target, which allows us to set an upper bound to carrier injection from other background defects. We attribute our observations to the action of unscreened Coulomb potentials producing giant carrier capture cross-sections, orders of magnitude greater than those measured in ensembles.

36 MATERIALS SCIENCE↗