Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Surface acoustic-wave piezoelectric crystal aerosol mass microbalance

The development of a particulate mass-sensing instrument based on a quartz-crystal microbalance and enhanced with the new surface acoustic-wave (SAW) technology is reported. Mass sensitivity comparisons of a 158-MHz SAW piezoelectric microbalance and a conventional 10-MHz quartz-crystal microbalance show that the SAW crystal is 266 times more sensitive, in good agreement with the theoretical value of 250. The frequency stability of a single SAW resonator is 6 parts in 10 to the 8th over 1 min. The response to temperature changes is found to be very linear over the range +30 to -30 C. A strong response to 15 ppm SO2 has been demonstrated on a chemically coated SAW crystal.

Bowers, W. D.↗

Lunar-surface UV Photometric Investigation of Exospheres (LUPINE): Thermal Modeling of Payload in a Relevant Daylit Environment

Direct upward remote sensing of the moon’s exosphere from a surface vantage can address production of water-related lunar volatiles as well as their exospheric loss, ballistic transport, and ultimate adsorption in permanently shadowed regions (PSRs). Far UV (FUV) dayside measurements of atomic oxygen, liberated from regolith by energetic solar protons and micrometeorite impact, can provide critical insight into the endogenic lunar water cycle by constraining total column density [O] at site of production. A notional Lunar-surface UV Photometric Investigation of Exospheres (LUPINE) instrument is designed to exploit solar-pumped atomic oxygen fluorescence at 130.4-nm, in a manner similar to the Apollo 17 UV Spectrometer (UVS) experiment [Fastie 1973; Feldman and Morrison, 1991] and the LRO Lyman-alpha Mapping Project (LAMP) spectrograph [Cook et al., 2013], by implementing a zenith-directed FUV photometer from the lunar surface at low (± 10°) selenographic latitude during the lunar day. Atomic oxygen production from solar energetic particle impact sources is thought to maximize in near solar noon [Sarantos et al., 2012], and the lander-embedded zenith-directed LUPINE photometer, in contrast to UVS and LAMP twilight measurements from orbit, can potentially capture the full column abundance of lunar regolith liberated oxygen. Herein we describe adaptation of FUV reflective optics, pulse-counting electronics, and scattered-light-suppression technologies developed for LEO FUV photometry for the challenging thermal environment of the daylit lunar surface. Preliminary thermal modeling and TVAC measurements of heritage FUV photometer components suggests that, if allowed to shed ~8W of waste heat into the bus of a reference Commercial Lunar Payload Services (CLPS) lander, the LUPINE photometer will be kept sufficiently cool to limit dark current to less than 20 counts/s. This level of dark signal enables an OI 130.4-nm 3-sigma detection threshold of ~1 mR for assumed 2-hour integrations.

Lunar UV Photometer↗

The Effects of Water Vapor and Clouds on the Spectral Distribution of Solar Radiation at the...

During the Subsonic Contrail and Cloud Effect Special Study (SUCCESS) a Solar Spectral Flux Radiometer was deployed at the surface in a zenith observing position. The instrument measured the solar spectral downwelling irradiance between 350 and 2500 nm with 10 nm resolution. From April 12 through April 29 approximately 18000 spectra were acquired, under a variety of meteorological conditions including cloud free, cirrus, Stearns, and cumulonimbus clouds. This study focuses on the effect of cirrus and cirrus contrails on the spectral distribution of solar irradiance at the surface and on inferring cirrus properties from their spectral transmittance. The observations have also proven to be useful for comparing the solar spectral irradiance measurements with model predictions, and in particular, for inferring the amount of solar radiation absorbed in the clear and cloudy atmosphere.

Pilewskie, P.↗

Europa Surface Radiation Environment for Lander Assessment

The Jovian magnetospheric particle environment at Europa's surface is critical to assessment of landed astrobiological experiments in three respects: (1) the landing site must be chosen for the best prospects for detectable organic or inorganic signs of Life, e.g. regions of freshly emergent flows from the subsurface; (2) lander systems must reach the surface through the Jovian magnetospheric environment and operate long enough on the surface to return useful data; (3) lander instrumentation must be capable of detecting signs of life in the context of the local environmental radiation and associated chemistry. The Galileo, Voyager, and Pioneer missions have provided a wealth of data on energetic particle intensities throughout the Jovian magnetosphere including from many flybys of Europa. cumulative radiation dosages for spacecraft enroute to Europa can be well characterized, but knowledge of the surface radiation environment is very limited. Energetic electrons should primarily impact the trailing hemisphere with decreasing intensity towards the center of the leading hemisphere and are the most significant radiation component down to meter depths in the surface regolith due to secondary interactions. Observed surface distribution for sulfates is suggestive of electron irradiation but may have alternative interpretations. Having much-larger magnetic gyroradii than electrons, energetic protons and heavier ions irradiate more of the global surface. The particular orientations of electron, proton, and ion gyromotion would project into corresponding directional (e.g., east-west) anisotropies of particle flu into the surface. Particular topographic features at the landing site may therefore offer shielding from part of the incident radiation.

Cooper, John F.↗

Calibration of the modulation transfer function of surface profilometers with binary pseudo-random test standards: Expanding the application range

A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010]. Here we report on a significant expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

47 OTHER INSTRUMENTATION↗

In-Situ Spectrometry of Neutrons

High energy charged particles of extra-galactic, galactic and solar origin collide with spacecraft structures in Earth orbit outside the atmosphere and in interplanetary travel beyond the Earth's magnetosphere. These primaries create a number of secondary particles inside the structures that can produce a significant ionizing radiation environment. This radiation is a threat to long term inhabitants or travelers for space missions and produces an increased risk of cancer and DNA damage. The primary high energy cosmic rays and trapped protons collide with common spacecraft materials such as aluminum and silicon and create secondary particles inside structures that are mostly protons and neutrons. Charged protons are readily detected and instruments are already in existence for this task. Neutrons are electrically neutral and therefore much more difficult to measure and detect. These neutrons are reported to contribute 30-60% of the dose inside space structures and cannot be ignored. Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary surfaces where astronauts will live and work. We propose to design and build a portable, low power and robust neutron spectrometer that will measure the neutron spectrum from 10 KeV to 500 MeV with at least 10% energy resolution in the various energy intervals. This instrument will monitor the existing neutron environment both inside spacecraft structures and on planetary surfaces to determine the safest living areas, warn of high fluxes associated with solar storms and assist the NSBRI Radiation Effects Team in making an accurate assessment of increased cancer risk and DNA damage to astronauts. The instrument uses a highly efficient proportional counter Helium 3 tube at the lowest energy intervals where .equivalent damage factors for tissue are the highest (10 KeV-2 MeV). The Helium 3 tube may be shielded with a cadmium absorber to eliminate the much less damaging, but more prevalent, thermal and epithermal neutrons and to make the structure of the spectrum more accurate in the 20 KeV-2 MeV range; or a pair of tubes, one shielded and one unshielded, can be combined so that the difference in their counts yields the thermal neutron contribution. The spectrometer also uses a 5mm lithium drifted bulk silicon solid state detector in the medium energy range of 2-20 Mev and two standard silicon surface barrier detectors separated by tens of millimeters behind a I cm thick polyethylene moderator in a stack or telescope arrangement for the high energy neutrons (>20 MeV). In the medium and high energy regions equivalent damage factors are lower but hits from one or a small number of neutrons may prove to be important. The silicon detector systems for medium and high energy neutrons will discriminate against charged particles by using a plastic cesium iodide scintillator of an appropriate geometry monitored by a silicon PIN photodiode.

Maurer, Richard H.↗

Automated Targeting for the MER Rovers

The Autonomous Exploration for Gathering Increased Science System (AEGIS) will soon provide automated targeting for remote sensing instruments on the Mars Exploration Rover (MER) mission, which currently which currently has two rovers exploring the surface of Mars. Currently, targets for rover remote-sensing instruments, especially narrow field-of-view instruments (such as the MER Mini- TES spectrometer or the 2011 Mars Science Laboratory (MSL) Mission ChemCam Spectrometer), must be selected manually based on imagery already on the ground with the operations team. AEGIS enables the rover flight software to analyze imagery onboard in order to autonomously select and sequence targeted remote-sensing observations in an opportunistic fashion. In this paper, we first provide some background information on the larger autonomous science framework in which AEGIS was developed. We then describe how AEGIS was specifically developed and tested on the JPL FIDO rover. Finally we discuss how AEGIS will be uploaded and used on the Mars Exploration Rover (MER) mission in early 2009.

rover autonomy↗

Turbulence measurements using tethered balloon instrumentation during FIRE 1987

As part of the surface-based observations conducted on San Nicolas Island, the U.K. Meteorological Office operated a set of turbulence probes attached to a balloon tether cable. Typically six probes were used, each capable of measuring momentum, heat, and humidity fluxes. Two probes were fitted with net radiometers, one positioned above cloud and the other below; a third probe carried a Lyman-alpha hygrometer fitted with a pre-heater for the measurement of total water content. Some preliminary results are presented from the 14th July describing the variation in structure of the cloudy boundary layer during the daytime. This day was characterized by a complete cloud cover, an inversion height of approximately 600 m. and north-westerly winds of approximately 6 m.s(-1). As an illustration the equivalent potential temperature derived from a profile ascent made between approximately 0830 and 0930 (PDT) is shown. The data has been smoothed to a height resolution of about 4 metres. At this time the cloud base was approximately 200 m. and very light drizzle was reaching the surface. The vertical velocity variance and potential temperature flux for two periods are shown; the first (shown by full lines) immediately follows the profile and the second (shown by dashed lines) is central around 1400 (PDT). The data have been normalized by their maximum values in the first period. Cloud base has now risen to approximately 300 m. There is a marked variation during the morning, particularly in sigma w. The net radiative flux above cloud top has by now reached its maximum value.

Hignett, Phillip↗

Artemis Internal Science Team Update: Crew Training

Astronauts will soon return to the Moon as part of Artemis — a campaign of crewed missions to explore the lunar surface. The first crewed Artemis missions include Artemis II, which will send four astronauts to lunar orbit to test the Orion spacecraft and observe the lunar surface; and Artemis III, the first human mission to land on the Moon in the vicinity of the South Pole. Artemis III surface objectives include lunar exploration through scientific traverses and observations, collection of lunar samples for Earth return, and deployment of scientific instruments. From this point, human missions to the lunar surface will continue under Artemis, with increasing exploration capability.

Artemis Science↗

Overview of GRC's Advanced Sensor and Instrumentation Development

Glenn Research Center develops advanced diagnostic techniques to measure surface and flow properties in research facilities. We support a variety of aerospace propulsion applications: Shuttle, X-33, X-43, ISS, and research engine components: inlets, compressors, combustors, nozzles. We are developing a suite of instrumentation specifically for 3rd Generation Reusable Launch Vehicle testing.

Mercer, Carolyn↗

Calibration of the TOPEX altimeter using a GPS buoy

The use of a spar buoy equipped with a Global Positioning System (GPS) antenna to calibrate the height measurement of the TOPEX radar altimeter is described. In order to determine the height of the GPS antenna phase center above the ocean surface, the buoy was also equipped with instrumentation to measure the instantaneous location of the waterline, and tilt of the bouy from vertical. The experiment was conducted off the California coast near the Texaco offshore oil platform, Harvest, during cycle 34 of the TOPEX/POSEIDON observational period. GPS solutions were computed for the bouy position using two different software packages, K&RS and GIPSY-OASIS II. These solutions were combined with estimates of the waterline location on the bouy to yield the height of the ocean surface. The ocean surface height in an absolute coordinate system combined with knowledge of the spacecraft height from tracking data provides a computed altimeter range measurement. By comparing this computed value to the actual altimeter measurement, the altimeter bias can be calibrated. The altimeter height bias obtained with the buoy using K&RS was -14.6 +/- 4 cm, while with GIPSY-OASIS II it was -13.1 +/- 4 cm. These are 0.1 cm and 1.6 cm different from the -14.7 +/- 4 cm result obtained for this flight overflight with the tide gauge instruments located on Platform Harvest.

Born, G. H.↗

X-ray Photon Correlation Spectroscopy Studies of Surfaces and Thin Films

The technique of X-ray Photon Correlation Spectroscopy (XPCS) is reviewed as a method for studying the relatively slow dynamics of materials on time scales ranging from microseconds to thousands of seconds and length scales ranging from microns down to nanometers. We focus on the application of this technique to study dynamical fluctuations of surfaces, interfaces and thin films. We first discuss instrumental issues such as the effects of partial coherence (or alternatively finite instrumental resolution) and optimization of signal-to-noise ratios in the experiments. We then review what has been learned from recent XPCS studies of capillary wave fluctuations on liquid surfaces and polymer films, of nanoparticles used as probes to study the interior dynamics of polymer films, of liquid crystals and multilamellar surfactant films, and of metal surfaces, and magnetic domain wall fluctuations in antiferromagnets. We then discuss studies of non-equilibrium dynamics described by 2-time correlation functions. Finally, we briefly speculate on possible future XPCS experiments at new synchrotron sources currently under development including studies of dynamics on time scales down to femtoseconds.

Sinha, Sunil K.↗

Airborne remote sensing measurements with a pulsed CO2 DIAL system

The present investigation is concerned with an optical radar instrument which has been developed for airborne remote sensing of atmospheric trace species at infrared wavelengths. The instrument makes use of compact, pulsed carbon dioxide lasers. It was designed for conducting differential absorption lidar (DIAL) measurements. The backscatter of laser pulse energy from the ocean and terrain surface is utilized to determine trace species column content. The instrument, which is carried by the NASA P3 aircraft, is used in a flight test program started in July 1981. The results obtained with the instrument in this program are discussed, taking into account ocean surface backscatter statistics, the ratio of ocean to terrain backscatter, the dual-wavelength correlation coefficient, the dual-wavelength cross-covariance, and the dependence of un-correlated noise variance on the mean backscatter signal.

Bufton, J. L.↗

Two Years of Chemical Sampling on Meridiani Planum by the Alpha Particle X-Ray Spectrometer Onboard the Mars Exploration Rover Opportunity

For over two terrestrial years, the Mars Exploration Rover Opportunity has been exploring the martian surface at Meridiani Planum using the Athena instrument payload [1], including the Alpha Particle X-Ray Spectrometer (APXS). The APXS has a small sensor head that is mounted on the robotic arm of the rover. The chemistry, mineralogy and morphology of selected samples were investigated by the APXS along with the Moessbauer Spectrometer (MB) and the Microscopic Imager (MI). The Rock Abrasion Tool (RAT) provided the possibility to dust and/or abrade rock surfaces down to several millimeters to expose fresh material for analysis. We report here on APXS data gathered along the nearly 6-kilometers long traverse in craters and plains of Meridiani.

Bruckner, J.↗

New AFM Techniques for Investigating Molecular Growth Mechanisms of Protein Crystals

Atomic Force Microscopy (AFM) has emerged as a powerful technique for investigating protein crystal growth. Earlier AFM studies were among the first to demonstrate that these crystals grew by dislocation and 2D nucleation growth mechanisms [1]. These investigations were restricted to the micron range where only surface features, such as dislocation hillocks and 2D islands are visible. Most AFM instruments can scan at higher resolutions and have the potential to resolve individual protein molecules at nanometer ranges. Such scans are essential for determining the molecular packing arrangements on crystal faces and for probing the growth process at the molecular level. However, at this resolution the AFM tip influences the image produced, with the resulting image being a convolution of the tip shape and the surface morphology [2]. In most studies this problem is resolved by deconvoluting the image to obtain the true surface morphology. Although deconvolution routines work reasonably well for simple one- dimensional shapes, for complex surfaces this approach does not produce accurate results. In this study we devised a new approach which takes advantage of the precise molecular order of crystal surfaces, combined with the knowledge of individual molecular shapes from the crystallographic data of the protein and the AFM tip shape. This information is used to construct expected theoretical AFM images by convoluting the tip shape with the constructed crystal surface shape for a given surface packing arrangement. By comparing the images from actual AFM scans with the constructed ones for different possible surface packing arrangements, the correct packing arrangement can be conclusively determined. This approach was used in this study to determine the correct one from two possible packing arrangements on (I 10) faces of tetragonal lysozyme crystals. Another novel AFM technique was also devised to measure the dimension of individual growth units of the crystal faces. Measuring these units was not attempted before and most studies have assumed that the growth unit consisted of individual protein molecules. The linescan mode of AFM instruments allows the crystal surface to be scanned along a single line. By scanning across a growth step an image showing the motion of the step is obtained. Normally such an image shows a straight line for continuous and constant step velocity. In this study by increasing the scan rate and by decreasing the step velocity (by decreasing the supersaturation), we were able to capture images of individual growth events, shown by jump discontinuities in the step line. By suitable integration of the image the growth unit dimension in the scanned direction can be obtained. Since multiple units can be involved in the growth process it is necessary to collect a statistically relevant sample before drawing conclusions about the growth mechanism. This technique was successfully employed to obtain the dimensions of growth units for the (110) face, showing that they consisted of various aggregates corresponding to the 43 helices in the crystal structure.

Li, Huayu↗

Encealdus Orbilander: A Flagship Mission Concept for Astrobiology

"Whether life exists beyond Earth remains a fundamental question driving our exploration of the Solar System. At Saturn’s moon Enceladus, plumes of oceanic material vented into space allow the investigation of the astrobiological potential of an ocean world, hinted at by Cassini, without the necessity of drilling through kilometers of ice crust. The Enceladus Orbilander is a flagship ($2.56B in fiscal year 2025 dollars) mission concept created for the 2023–2033 Planetary Science Decadal Survey. Orbilander takes full advantage of the opportunity provided by Enceladus’ plumes to search for signs of life. A single spacecraft both orbits and lands, capturing samples from four distinct reservoirs offered by the plumes. These samples, both particulate and vapor, are then analyzed by the Life Detection Suite (LDS), a set of five instruments conducting complementary and orthogonal biosignature-seeking measurements. To provide the context that specifically enhances interpretation of LDS measurements, geochemical and geophysical investigations are conducted both in orbit and on the surface. These reveal the physio-chemical state of the ocean and core as well as the processes involved in ejection of plume material and how these affect the ocean material analyzed by the LDS. The Orbilander can be delivered to the Saturn system via several launch vehicle and trajectory options, including a direct trajectory (7-year cruise), a ∆V-EGA trajectory (9-year cruise) and several options using an inner cruise with Venus and Earth flybys (10-year cruise). Upon Saturn Orbit Insertion, a 4-year moon tour pumps down the Orbilander’s orbit to intercept Enceladus. The most optimal arrival times balance the Jupiter flyby opportunities of the late 2030s and solar illumination at the Enceladus high southern latitudes where plume material is most abundant. This mission concept therefore targets project start in 2030. Upon Enceladus Orbit Insertion, the Orbilander begins a 1.5-year-long campaign of landing site reconnaissance, remote sensing science, and collecting sufficient plume sample to run all but one of the LDS measurements. After successful landing, the Orbilander spends 2 years on the surface conducting multiple LDS measurements with all five instruments on actively and passively collected plume material, as well as seismic investigations. The schedule laid out here is well-defined, but the mission also has operational and resource flexibility should additional reconnaissance be needed. As part of the design study, mission and development risks were identified and mitigation strategies proposed. Technologies key to achieving the life detection science objectives include instrumentation matured under programs like COLDTech and ICEE-2, such as aspects of the sampling system and microfluidic devices, as well as well-known techniques like high-resolution and separation-capable mass spectrometers. Autonomous onboard navigation is planned to maintain a halo orbit around Enceladus to enable passive sampling from orbit as well as reconnaissance measurements for use in site selection and landing. Terrain relative navigation is included to ensure safe landing, given that targeted areas may contain landing hazards. Continued development of radioisotope thermoelectric generator (RTG) technology and long-life batteries is essential for this long duration mission. The Enceladus Orbilander represents an optimal point in the trade space of science value versus cost, taking advantage of the extensive knowledge of Enceladus provided by Cassini, how well Enceladus lends itself to a search for life in material from its ocean, and the flexibility afforded by the innovative design developed by the APL team. By taking full advantage of Enceladus’ plumes both in orbit and on the surface, Orbilander represents a robust search for life with complementary and orthogonal biosignatures as well as contextual geophysical and geochemical measurements, determining not only whether Enceladus is inhabited (at levels up to 500,000× scarcer than in Earth’s oceans) but also why. "

Exobiology↗

On the use of DSCOVR EPIC to monitor the visible calibration stability of polar orbiting imagers to improve the next edition of the CERES climate data record.

The NASA CERES project has provided the climate quality observed TOA and computed surface fluxes to the scientific community. CERES instruments are onboard the Terra, Aqua, NPP, and NOAA-20 spacecraft. CERES uses MODIS and VIIRS imagers to retrieve cloud properties needed to convert CERES footprint radiance observations into fluxes using empirically derived angular directional models obtained during early CERES record. CERES utilizes geostationary sensors to infer the regional diurnal fluxes in between Terra and Aqua CERES observations. The imagers are also used to radiometrically scale the geostationary sensors (GEO) radiances to the imager calibration reference to ensure that the GEO derived cloud properties and broadband TOA fluxes are consistent in both space and time. Both the imager and GEO retrieved cloud properties are used to compute the surface fluxes. The Aqua-MODIS, SNPP-VIIRS, and NOAA-20 VIIRS afternoon imagers will also need to be radiometrically scaled to the same common calibration reference. Although all three imagers employ onboard solar diffusers, the calibration is not consistent over time due to instrument anomalies and ageing of the onboard calibrators. The CERES imager and GEO calibration group (IGCG) has been tasked to remove the imager channel calibration drifts for the next CERES reprocessing effort. The team will rely primarily on deep convective clouds, desert, and polar ice invariant targets to monitor the imager channel stability. The team uses ray-matched radiance pairs to radiometrically scale the SNPP and NOAA-20 VIIRS sensors to Aqua-MODIS. The radiometric scaling is further validated using geostationary imagers as transfer radiometers. The DSCOVR satellite was launched on February 25, 2015 and orbits around the L1 Lagrange point directly between the Earth and the sun. The EPIC instrument onboard DSCOVR employs a CCD array to image the Earth approximately every 2-hours. The EPIC sensor contains no onboard calibration systems. However, multiple inter-calibration studies have shown that the EPIC imager is very stable in time. This is likely due to the DSCOVR satellite being located about a 1.5M km from the Earth, where very little Earth reflected solar radiation degrades the optics. The excellent radiometric stability of EPIC allows the CERES IGCG to utilize the EPIC observations as a stable reference for monitoring the calibration stability of the three afternoon imagers, as well as to validate the radiometric scaling factors between them. Examples of the imager relative calibration using EPIC before and after radiometric scaling will be shown along with the results from the use of invariant targets to remove imager calibration drifts.

DSCOVR-EPIC↗