Search NASA⌕ Search

SEARCH · Search NASA

Results for “test correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

RELIABILITY OF THE DETECTION OF THE BARYON ACOUSTIC PEAK

The correlation function of the distribution of matter in the universe shows, at large scales, baryon acoustic oscillations, which were imprinted prior to recombination. This feature was first detected in the correlation function of the luminous red galaxies of the Sloan Digital Sky Survey (SDSS). Recently, the final release (DR7) of the SDSS has been made available, and the useful volume is about two times bigger than in the old sample. We present here, for the first time, the redshift-space correlation function of this sample at large scales together with that for one shallower, but denser volume-limited subsample drawn from the Two-Degree Field Redshift Survey. We test the reliability of the detection of the acoustic peak at about 100 h {sup -1} Mpc and the behavior of the correlation function at larger scales by means of careful estimation of errors. We confirm the presence of the peak in the latest data although broader than in previous detections.

79 ASTRONOMY AND ASTROPHYSICS↗

Bridging the length scales on mechanical property evaluation (Final Report)

The development of small-scale mechanical testing in combination with microstructural investigation is of great interest to the nuclear materials community for both materials development and monitoring applications. Dramatically reducing the sample sizes to reduce radioactivity and obtaining mechanical properties of irradiated samples is truly intriguing. Moreover, such studies promise a range of benefits including cost reduction, fundamental insight in structure-property relationships, increased statistics on less sample material, and reinvestigation of prior irradiated and tested reactor samples while simultaneously enabling the generation of mechanical test data on ion beam irradiated materials with limited penetration depths. Small scale materials testing on sub-sized samples has been studied for several decades, though it has only been after the development of micro-testing based on Focused Ion Beam (FIB) sample manufacturing in that orders of magnitude smaller samples could really be investigated in a quantitative manner. In recent years, small scale mechanical testing techniques at a number of length scales has been developed for both unirradiated and irradiated (ion and neutron) materials. Technological advances made in this field have enabled ex-situ and in-situ transmission electron microscopy (TEM) and scanning electron microscopy (SEM) examination, thus leading to more accurate measurements as well as additional mechanistic information. A recent review of the benefits of these techniques show that these techniques are at a stage to tackle multi-scale ranges of materials investigations and can be utilized to obtain fundamental science-based understanding of nuclear materials. Considering the tremendous advances made, one can see how small-scale mechanical testing techniques combined with modeling can enable true small scale to bulk scale mechanical property correlations. However, for the engineering community to adapt this approach fully, one needs to demonstrate that a) that these techniques can produce results with high fidelity and reproducibility, b) generate engineering stress-strain data that one can utilize to understand bulk behavior, and c) generate new insight into relevant phenomena fostering the true understanding of radiation damage and microstructure in materials for nuclear applications. It is the objective of this proposal to bridge the length scale between macro- and micro- scale mechanical testing of unirradiated and irradiated materials. This involves the development and demonstration of procedures for multi-scale mechanical testing that enable high fidelity reproducibility of data and the generation bulk property data from small-scale mechanical tests. Through this, the proposal aims to enhance the confidence in the obtained data at the smaller length scales and enhance the insight provided from these techniques for bulk scale applications on both unirradiated and irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Disentangling Alzheimer’s disease neurodegeneration from typical brain ageing using machine learning

Abstract Neuroimaging biomarkers that distinguish between changes due to typical brain ageing and Alzheimer’s disease are valuable for determining how much each contributes to cognitive decline. Supervised machine learning models can derive multivariate patterns of brain change related to the two processes, including the Spatial Patterns of Atrophy for Recognition of Alzheimer’s Disease (SPARE-AD) and of Brain Aging (SPARE-BA) scores investigated herein. However, the substantial overlap between brain regions affected in the two processes confounds measuring them independently. We present a methodology, and associated results, towards disentangling the two. T1-weighted MRI scans of 4054 participants (48–95 years) with Alzheimer’s disease, mild cognitive impairment (MCI), or cognitively normal (CN) diagnoses from the Imaging-based coordinate SysTem for AGIng and NeurodeGenerative diseases (iSTAGING) consortium were analysed. Multiple sets of SPARE scores were investigated, in order to probe imaging signatures of certain clinically or molecularly defined sub-cohorts. First, a subset of clinical Alzheimer’s disease patients (n = 718) and age- and sex-matched CN adults (n = 718) were selected based purely on clinical diagnoses to train SPARE-BA1 (regression of age using CN individuals) and SPARE-AD1 (classification of CN versus Alzheimer’s disease) models. Second, analogous groups were selected based on clinical and molecular markers to train SPARE-BA2 and SPARE-AD2 models: amyloid-positive Alzheimer’s disease continuum group (n = 718; consisting of amyloid-positive Alzheimer’s disease, amyloid-positive MCI, amyloid- and tau-positive CN individuals) and amyloid-negative CN group (n = 718). Finally, the combined group of the Alzheimer’s disease continuum and amyloid-negative CN individuals was used to train SPARE-BA3 model, with the intention to estimate brain age regardless of Alzheimer’s disease-related brain changes. The disentangled SPARE models, SPARE-AD2 and SPARE-BA3, derived brain patterns that were more specific to the two types of brain changes. The correlation between the SPARE-BA Gap (SPARE-BA minus chronological age) and SPARE-AD was significantly reduced after the decoupling (r = 0.56–0.06). The correlation of disentangled SPARE-AD was non-inferior to amyloid- and tau-related measurements and to the number of APOE ε4 alleles but was lower to Alzheimer’s disease-related psychometric test scores, suggesting the contribution of advanced brain ageing to the latter. The disentangled SPARE-BA was consistently less correlated with Alzheimer’s disease-related clinical, molecular and genetic variables. By employing conservative molecular diagnoses and introducing Alzheimer’s disease continuum cases to the SPARE-BA model training, we achieved more dissociable neuroanatomical biomarkers of typical brain ageing and Alzheimer’s disease.

Hwang, Gyujoon↗

Massively parallel reporter assays and mouse transgenic assays provide correlated and complementary information about neuronal enhancer activity

High-throughput massively parallel reporter assays (MPRAs) and phenotype-rich in vivo transgenic mouse assays are two potentially complementary ways to study the impact of noncoding variants associated with psychiatric diseases. Here, we investigate the utility of combining these assays. Specifically, we carry out an MPRA in induced human neurons on over 50,000 sequences derived from fetal neuronal ATAC-seq datasets and enhancers validated in mouse assays. We also test the impact of over 20,000 variants, including synthetic mutations and 167 common variants associated with psychiatric disorders. We find a strong and specific correlation between MPRA and mouse neuronal enhancer activity. Four out of five tested variants with significant MPRA effects affected neuronal enhancer activity in mouse embryos. Mouse assays also reveal pleiotropic variant effects that could not be observed in MPRA. Our work provides a catalog of functional neuronal enhancers and variant effects and highlights the effectiveness of combining MPRAs and mouse transgenic assays.

Kosicki, Michael↗

Novel scanning electron microscope bulge test technique integrated with loading function

Membranes and film-on-substrate structures are critical elements for some devices in electronics industry and for Micro Electro Mechanical Systems devices. These structures are normally at the scale of micrometer or even nanometer. Thus, the measurement for the mechanical property of these membranes poses a challenge over the conventional measurements at macro-scales. In this study, a novel bulge test method is presented for the evaluation of mechanical property of micro thin membranes. Three aspects are discussed in the study: (a) A novel bulge test with a Scanning Electron Microscope system realizing the function of loading and measuring simultaneously; (b) a simplified Digital Image Correlation method for a height measurement; and (c) an imaging distortion correction by the introduction of a scanning Moiré method. Combined with the above techniques, biaxial modulus as well as Young's modulus of the polyimide film can be determined. Besides, a standard tensile test is conducted as an auxiliary experiment to validate the feasibility of the proposed method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On-Line Monitoring to Detect Sensor and Process Degradation under Normal Operational Transients - 327

Calibration assessment of nuclear plant sensors and transmitters is currently performed through periodic maintenance actions during plant refueling outages. On-line monitoring (OLM) can be used to reduce the time and cost of this maintenance process by using empirical models to evaluate sensor calibration. The implementation of OLM can also mitigate human error associated with unnecessary maintenance on sensors operating within calibration tolerances. OLM has been studied and validated for plants under steady-state baseload operation, but the extension to load-following operation is not well-documented in the literature. Auto-associative kernel regression (AAKR) provides an error-corrected prediction of process sensor measurements for OLM through a weighted average of historic data. The current study evaluates the performance of AAKR for prediction under normal operational transients (such as expected under load-following operation). Performance of the AAKR model with two anomaly detection routines, error uncertainty limit monitoring (EULM) and sequential probability ratio test (SPRT), was evaluated for normal operation, sensor faults, and process degradation. The data used to develop and evaluate the OLM system were collected from a forced flow loop with temperature and flow sensors. Three models of well-correlated groups of sensors are trained to predict normal system behavior under planned transients. The anomaly detection routines are tested for sensor faults and process faults. The results of this experimental study suggest AAKR and an appropriate anomaly detection routine can be applied for sensor calibration and process fault detection under transient operation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Solid Electrolyte Interphase Dispersion Can Predict Cycle and Calendar Lifetimes in Silicon Anodes for Lithium-Ion Batteries

The solid electrolyte interphase (SEI) plays a critical role in lithium-ion battery (LIB) anodes. It is responsible for passivating the reactive surface of lithiated anodes against degradation of the electrolyte which enables long cycle and calendar lifetimes for LIBs. This role is especially important in high energy density anodes like silicon, that undergo massive volumetric changes during electrochemical cycling. The mechanism by which the SEI performs this role, however, is not clear which makes designing an SEI to passivate silicon anodes impossible. Through decades of research, dozens of chemical species have been identified within the SEI ranging from inorganic solids to polymeric coatings all of which simultaneously exist in a 'mosaic' composition at the anode surface. This mosaic creates a highly dispersive environment in which electrostatic screening of the anode surface from the electrolyte is not always complete. Here, we present an electrochemical technique to directly test the dispersion at the anode surface. We use this technique to screen more than 20 different electrolytes against silicon anodes and find correlations between both the cycle life and calendar life. The insights from this study offer a new framework to think about the SEI and a rapid screening method to test novel electrode/electrolyte combinations.

battery↗

Experimental Evaluation of Dual-Opposed Jet Mixer Pump Performance for Slurry Mixing

Million-gallon double-shell tanks at Hanford are used to store transuranic, high-level, and low-level radioactive wastes. These wastes consist of a large volume of salt-laden solution covering a smaller volume of settled sludge primarily containing metal hydroxides. These wastes will be retrieved and processed into immobile waste forms suitable for permanent disposal. Retrieval is an important step in implementing these disposal scenarios. The retrieval concept evaluated is to use submerged dual-nozzle jet mixer pumps with horizontally oriented nozzles located near the tank floor that produce horizontal jets of fluid to mobilize the settled solids. The mixer pumps are oscillated through 180 about a vertical axis so the high velocity fluid jets sweep across the floor of the tank. After the solids are mobilized, the pumps will continue to operate at a reduced flow rate producing lower velocity jets sufficient to maintain the particles in a uniform suspension (concentration uniformity). Several types of waste and tank configurations exist at Hanford. The jet mixer pump systems and operating conditions required to mobilize sludge and maintain slurry uniformity will be a function of the waste type and tank configuration. The focus of this work was to conduct a 1/12-scale experiment to develop an analytical model to relate slurry uniformity to tank and mixer pump configurations, operating conditions, and sludge properties. This experimental study evaluated concentration uniformity in a 1/12-scale experiment varying the Reynolds number (Re), Froude number (Fr), and gravitational settling parameter (Gs) space. Simulant physical properties were chosen to obtain the required Re and Gs where Re and Gs were varied by adjusting the kinematic viscosity and mean particle diameter, respectively. Test conditions were achieved by scaling the jet nozzle exit velocity in a 75-in. diameter tank using a mock-up of a centrally located dual-opposed jet mixer pump located just above the tank floor. Concentration measurements at sampling locations throughout the tank were used to assess the degree of uniformity achieved during each test. Concentration data was obtained using a real time in-situ ultrasonic attenuation probe and post-test analysis of discrete batch samples. The undissolved solids concentration at these locations was analyzed to determine whether the tank contents were uniform (≤ ±10% variation about mean) or nonuniform (> ±10% variation about mean) in concentration. Concentration inhomogeneity was modeled as a function of dimensionless parameters. The parameters that best describe the maximum solids volume fraction that can be suspended were found to be 1) the Fr based on nozzle average discharge velocity and tank contents level and 2) the dimensionless particle size based on nozzle diameter. The dependence on the jet Re does not appear to be statistically significant.

correlation↗

High temperature high velocity direct power extraction using an open-cycle oxy-combustion system

The implementation of oxy-fuel technology in fossil-fuel power plants may contribute to increased system efficiencies and a reduction of pollutant emissions. One technology that has potential to utilize the temperature of undiluted oxy-combustion flames is open-cycle magnetohydrodynamic (MHD) power generators. These systems can be configured as a topping cycle and provide high enthalpy, electrically conductive flows for direct conversion of electricity. This report presents the design and modeling strategies of a MHD combustor operating at temperatures exceeding 3000 K. Throughout the study, computational fluid dynamics (CFD) models were extensively used as a design and optimization tool. A lab-scale 60 kWth model was designed, manufactured and tested as part of this project. A fully-coupled numerical method was developed in ANSYS FLUENT to characterize the heat transfer in the system. This study revealed that nozzle heat transfer may be predicted through a 40% reduction of the semi-empirical Bartz correlation. Experimental results showed good agreement with the numerical evaluation, with the combustor exhibiting a favorable performance when tested during extended time periods. A transient numerical method was employed to analyze fuel injector geometries for the 60-kW combustor. The ANSYS FLUENT study revealed that counter-swirl inlets achieve a uniform pressure and velocity ratio when the ports of the injector length to diameter ratio (L/D) is 4. An angle of 115 degrees was found to increase distribution efficiency. The findings show that this oxy-combustion concept is capable of providing a high-enthalpy environment for seeding, in order to render the flow to be conductive. Based on previous findings, temperatures in the range of 2800-3000 K may enable magnetohydrodynamic power extraction. The heat loss fraction in this oxy-combustion system, based on CFD and analytical calculations, at optimal operating conditions, was estimated to be less than 10 percent. Furthermore, the heat transfer design removed approximately 7 MW/m2. The results observed in the lab-scale system were employed to develop a 1-MW scaled prototype. Scaling methods were based on critical design criteria found in similar systems, aimed at replicating combustion flow fields and reducing possible instabilities. A numerical simulation of the combustor wall was developed for a combined thermal steady model and static structural model. This combined model was developed predict combined stress parameters within the wall during testing conditions. Both models were developed within ANSYS FEA software package. The relative accuracy presented as well major performance parameters are discussed to assess the design's validity and ensure safety. The scaled prototype was manufactured through selective laser melting (SLM)-based additive manufacturing to reduce lead times and increase geometrical complexity. Additional CFD models were developed to optimize coolant manifold system parameters and perform a parametric study on channel geometry. An investigation on coolant manifold geometry demonstrated improvements in channel flow distribution when enlarging manifold lengths and increasing the number of tubes feeding into the flow. A three-dimensional model based on a single channel was developed to capture the effect of variable properties and thermal stratification. All cases in the simulation exhibited higher wall temperatures and lower convective coefficients than those determined through 1-D analytical equations. This implies that pressure and velocity safety factors must be implemented during system operation. Overall, the findings made in this investigation are thought to be of value to researchers and industrial practitioners when designing oxy-fuel direct power extraction systems operating at temperatures exceeding 3000 K. In addition to this, the implementation of the developed technology at pilot and commercial scales could result in a significant improvement in the efficiencies of heritage and next-generation power cycles.

03 NATURAL GAS↗

3D DVH-based metric analysis versus per-beam planar analysis in IMRT pretreatment verification

Purpose: To evaluate methods of pretreatment IMRT analysis, using real measurements performed with a commercial 2D detector array, for clinical relevance and accuracy by comparing clinical DVH parameters. Methods: We divided the work into two parts. The first part consisted of six in-phantom tests aimed to study the sensitivity of the different analysis methods. Beam fluences, 3D dose distribution, and DVH of an unaltered original plan were compared to those of the delivered plan, in which an error had been intentionally introduced. The second part consisted of comparing gamma analysis with DVH metrics for 17 patient plans from various sites. Beam fluences were measured with the MapCHECK 2 detector, per-beam planar analysis was performed with the MapCHECK software, and 3D gamma analysis and the DVH evaluation were performed using 3DVH software. Results: In a per-beam gamma analysis some of the tests yielded false positives or false negatives. However, the 3DVH software correctly described the DVH of the plan which included the error. The measured DVH from the plan with controlled error agreed with the planned DVH within 2% dose or 2% volume. We also found that a gamma criterion of 3%/3 mm was too lax to detect some of the forced errors. Global analysis masked some problems, while local analysis magnified irrelevant errors at low doses. Small hotspots were missed for all metrics due to the spatial resolution of the detector panel. DVH analysis for patient plans revealed small differences between treatment plan calculations and 3DVH results, with the exception of very small volume structures such as the eyes and the lenses. Target coverage (D{sub 98} and D{sub 95}) of the measured plan was systematically lower than that predicted by the treatment planning system, while other DVH characteristics varied depending on the parameter and organ. Conclusions: We found no correlation between the gamma index and the clinical impact of a discrepancy for any of the gamma index evaluation possibilities (global, local, 2D, or 3D). Some of the tests yielded false positives or false negatives in a per-beam gamma analysis. However, they were correctly accounted for in a DVH analysis. We also showed that 3DVH software is reliable for our tests, and is a viable method for correlating planar discrepancies with clinical relevance by comparing the measured DVH of target and OAR's with clinical tolerance.

60 APPLIED LIFE SCIENCES↗

Mitigating the noise of DESI mocks using analytic control variates

In order to address fundamental questions related to the expansion history of the Universe and its primordial nature with the next generation of galaxy experiments, we need to model reliably large-scale structure observables such as the correlation function and the power spectrum. Cosmological N-body simulations provide a reference through which we can test our models, but their output suffers from sample variance on large scales. Fortunately, this is the regime where accurate analytic approximations exist. To reduce the variance, which is key to making optimal use of these simulations, we can leverage the accuracy and precision of such analytic descriptions using Control Variates (CV). The power of control variates stems from utilizing inexpensive but highly correlated surrogates of the statistics one wishes to measure. The stronger the correlation between the surrogate and the statistic of interest, the larger the variance reduction delivered by the method. We apply two control variate formulations to mock catalogs generated in anticipation of upcoming data from the Dark Energy Spectroscopic Instrument (DESI) to test the robustness of its analysis pipeline. Our CV-reduced measurements offer a factor of 5-10 improvement in the measurement error compared with the raw measurements. We explore the relevant properties of the galaxy samples that dictate this reduction and comment on the improvements we find on some of the derived quantities relevant to Baryon Acoustic Oscillation (BAO) analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Lymphopenia Association With Gross Tumor Volume and Lung V5 and Its Effects on Non-Small Cell Lung Cancer Patient Outcomes

Purpose: Radiation therapy (RT) can both suppress and stimulate the immune system. We sought to investigate the mechanisms underlying radiation-induced lymphopenia and its associations with patient outcomes in non-small cell lung cancer (NSCLC). Methods and Materials: Subjects consisted of 711 patients who had received definitive RT for NSCLC. A lymphocyte nadir was calculated as the minimum lymphocyte value measured during definitive RT. Associations between gross tumor volumes (GTVs) and lung dose-volume histogram (DVH) parameters with lymphocyte nadirs were assessed with Spearman correlation coefficients. Relationships between lymphocyte nadirs with overall survival (OS) and event free survival (EFS) were evaluated with Kaplan-Meier analysis and compared with log-rank test results. Multivariate regressions were conducted with linear and Cox regression analyses. All variables were analyzed as continuous if possible. Results: Larger GTVs were correlated with lower lymphocyte nadirs regardless of concurrent chemotherapy receipt (with concurrent: r = −0.26, P<.0001; without: r = −0.48, P<.0001). Analyses of lung DVH parameters revealed significant correlations at lower doses (lung V5-V10: P<.0001) that incrementally decreased and became nonsignificant at higher doses (lung V60-V70: P>.05). Of note, no significant associations were detected between GTV and lung DVH parameters with total leukocyte, neutrophil, or monocyte nadirs during RT or with lymphocyte count prior to RT. Multivariate analysis revealed larger GTV (P<.0001), receipt of concurrent chemotherapy (P<.0001), twice-daily radiation fractionation (P=.02), and stage III disease (P=.05) to be associated with lower lymphocyte nadirs. On univariate analysis, patients with higher lymphocyte nadirs exhibited significantly improved OS (hazard ratio [HR] = 0.51 per 10{sup 3} lymphocytes/μL, P=.01) and EFS (HR = 0.46 per 10{sup 3} lymphocytes/μL, P<.0001). These differences held on multivariate analyses, controlling for common disease and treatment characteristics including GTV. Conclusions: Lower lymphocyte nadirs during definitive RT were associated with larger GTVs and worse patient outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Glass production rate in electric furnaces for radioactive waste vitrification

Correlating the melting rates of feeds in electric melters with results of simple laboratory experiments can help evaluate melter feed additives and their effects on melting rate, and support the feed scheduling and plant operation. A recently proposed melting rate correlation (MRC) equation, relating the melting rate to melt viscosity, feed-to-glass conversion heat, and cold-cap bottom temperature, was tested using data from experiments covering various feed compositions and melter operating parameters. The MRC equation is shown to reasonably represent the measured data and thus can be used to quantify how individual variables (melt viscosity, cold-cap bottom temperature, conversion heat, melter operating temperature, and bubbling rate) affect the glass production rate.

Lee, Seung Min↗

Solid State Lighting Program (Falcon)

Over the past two years, KLA-Tencor and partners successfully developed and deployed software and hardware tools that increase product yield for High Brightness LED (HBLED) manufacturing and reduce product development and factory ramp times. This report summarizes our development effort and details of how the results of the Solid State Light Program (Falcon) have started to help HBLED manufacturers optimize process control by enabling them to flag and correct identified killer defect conditions at any point of origin in the process manufacturing flow. This constitutes a quantum leap in yield management over current practice. Current practice consists of die dispositioning which is just rejection of bad die at end of process based upon probe tests, loosely assisted by optical in-line monitoring for gross process deficiencies. For the first time, and as a result of our Solid State Lighting Program, our LED manufacturing partners have obtained the software and hardware tools that optimize individual process steps to control killer defects at the point in the processes where they originate. Products developed during our two year program enable optimized inspection strategies for many product lines to minimize cost and maximize yield. The Solid State Lighting Program was structured in three phases: i) the development of advanced imaging modes that achieve clear separation between LED defect types, improves signal to noise and scan rates, and minimizes nuisance defects for both front end and back end inspection tools, ii) the creation of defect source analysis (DSA) software that connect the defect maps from back-end and front-end HBLED manufacturing tools to permit the automatic overlay and traceability of defects between tools and process steps, suppress nuisance defects, and identify the origin of killer defects with process step and conditions, and iii) working with partners (Philips Lumileds) on product wafers, obtain a detailed statistical correlation of automated defect and DSA map overlay to failed die identified using end product probe test results. Results from our two year effort have led to “automated end-to-end defect detection” with full defect traceability and the ability to unambiguously correlate device killer defects to optically detected features and their point of origin within the process. Success of the program can be measured by yield improvements at our partner’s facilities and new product orders.

Meeks, Steven↗

On the validity of the Poisson assumption in sampling nanometer-sized aerosols

A Poisson process is traditionally believed to apply to the sampling of aerosols. For a constant aerosol concentration, it is assumed that a Poisson process describes the fluctuation in the measured concentration because aerosols are stochastically distributed in space. Recent studies, however, have shown that sampling of micrometer-sized aerosols has non-Poissonian behavior with positive correlations. The validity of the Poisson assumption for nanometer-sized aerosols has not been examined and thus was tested in this study. Its validity was tested for four particle sizes - 10 nm, 25 nm, 50 nm and 100 nm - by sampling from indoor air with a DMA- CPC setup to obtain a time series of particle counts. Five metrics were calculated from the data: pair-correlation function (PCF), time-averaged PCF, coefficient of variation, probability of measuring a concentration at least 25% greater than average, and posterior distributions from Bayesian inference. To identify departures from Poissonian behavior, these metrics were also calculated for 1,000 computer-generated Poisson time series with the same mean as the experimental data. For nearly all comparisons, the experimental data fell within the range of 80% of the Poisson-simulation values. Essentially, the metrics for the experimental data were indistinguishable from a simulated Poisson process. The greater influence of Brownian motion for nanometer-sized aerosols may explain the Poissonian behavior observed for smaller aerosols. Although the Poisson assumption was found to be valid in this study, it must be carefully applied as the results here do not definitively prove applicability in all sampling situations.

concentration measurement↗

Tracking Replicate Divergence in Microbial Community Composition and Function in Experimental Microcosms

The study of microbial community functions necessitates replicating microbial communities. Variation in community development over time renders this an imperfect process. Thus, anticipating the likely degree of variation among replicate communities may aid in experimental design. We examined divergence in replicate community composition and function among 128 naturally assembled starting communities obtained from soils, each replicated three times, following a 30-day microcosm incubation period. Bacterial and fungal communities diverged in both composition and function among replicates, but remained much more similar to each other than to communities from different starting inocula. Variation in bacterial community composition among replicates was, however, correlated with variation in dissolved organic carbon production. A smaller-scale experiment testing nine starting communities showed that divergence was similar whether replicates were incubated on sterile or non-sterile pine litter, suggesting the impact of a pre-existing community on replicate divergence is minor. However, replicates in this experiment which were incubated for 114 days diverged more than those incubated for 30 days, suggesting experiments that run over long time periods will likely see greater variation among replicate community composition. Here these results suggest that while replicates diverge at a community level, such divergence is unlikely to severely impede the study of community function.

59 BASIC BIOLOGICAL SCIENCES↗

Change in Porosity of A356 by Holding Time and Its Effect on Mechanical Properties

In most of the practical casting operations, it is important to be able to cast large number of part with one single melt. Therefore, when quantity of the charge and melting crucible is increased, during casting process, the liquid is led to settle for a long period of time. In this work, 10 kg charge of A356 was melted at 750 °C and held for 240 min. A sand mold with different thickness was cast at 30, 60, 120, and 240 min of holding time of the liquid, before and after degassing conditions. Melt quality was measured by reduced pressure test, and pore size and number were measured at each cast part. A correlation between bifilm index and tensile properties was established. It was found that melt quality was decreased with increased holding time and pore formation was enhanced linearly. Additionally, mechanical properties of the alloy were decreased with decreased melt quality and increased pore formation due to holding time of the liquid.

36 MATERIALS SCIENCE↗

Therapeutic Potential of DNAzyme Loaded on Chitosan/Cyclodextrin Nanoparticle to Recovery of Chemosensitivity in the MCF-7 Cell Line

Commonly, acquired resistances to anticancer drug are mediated by overexpression of a membrane-associated protein that encode via multi-drug resistance gene-1 (MDR1). Herein, the mRNA-cleaving DNAzyme that targets the mRNA of MDR1 gene in doxorubicin-resistant breast cancer cell line (MCF-7/DR) loaded on the chitosan β-cyclodextrin complexes was used as a tropical agent. Chitosan/β-cyclodextrin complexes were used to deliver DNAzymes into cancer cells. Determination of the physicochemical characteristics of the particles was done by photon correlation spectroscopy and scanning electron microscopy. The encapsulation efficiency of the complexes was tested by using gel retardation assay. Positively charged nanoparticles interacted with DNAzyme that could perform as an efficient DNAzyme transfection system. The rationale usage of this platform is to sensitize MCF-7/DR to doxorubicin by downregulating the drug-resistance gene MDR1. Results demonstrated a downregulation of MDR1 mRNAs in MCF-7/DR/DNZ by real-time PCR, compared to the MCF-7/DR as control. WST1 assay showed the 22-fold decrease in drug resistance on treated cells 24 h after transfection. Results showed the intracellular accumulation of Rh123 increased in the treated cells with DNAzyme. Results suggested a potential platform in association with chemotherapy drug for cancer therapy and indicated extremely efficient at delivery of DNAzyme in restoring chemosensitivity.

60 APPLIED LIFE SCIENCES↗