Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Approximate Green's function methods for HZE transport in multilayered materials

A nonperturbative analytic solution of the high charge and energy (HZE) Green's function is used to implement a computer code for laboratory ion beam transport in multilayered materials. The code is established to operate on the Langley nuclear fragmentation model used in engineering applications. Computational procedures are established to generate linear energy transfer (LET) distributions for a specified ion beam and target for comparison with experimental measurements. The code was found to be highly efficient and compared well with the perturbation approximation.

Wilson, John W.↗

McMillan Lens in a System with Space Charge

Space charge (SC) in a circulating beam in a ring produces both betatron tune shift and betatron tune spread. These effects make some particles move on to a machine resonance and become unstable. Linear elements of beam optics cannot reduce the tune spread induced by SC because of its intrinsic nonlinear nature. We investigate the possibility to mitigate it by a thin McMillan lens providing a nonlinear axially symmetric kick, which is qualitatively opposite to the accumulated kick by SC. Experimentally, the proposed concept can be tested in Fermilab's IOTA ring. A thin McMillan lens can be implemented by a short (70 cm) insertion of an electron beam with specifically chosen density distribution in transverse directions. In this article, to see if McMillan lenses reduce the tune spread induced by SC, we make several simulations with particle tracking code Synergia. We choose such beam and lattice parameters that tune spread is roughly 0.5 and a beam instability due to the half-integer resonance 0.5 is observed. Then, we try to reduce emittance growth by shifting betatron tunes by adjusting quadrupoles and reducing the tune spread by McMillan lenses.

43 PARTICLE ACCELERATORS↗

A nanotube based electron microbeam cellular irradiator for radiobiology research

A prototype cellular irradiator utilizing a carbon nanotube (CNT) based field emission electron source has been developed for microscopic image-guided cellular region irradiation. The CNT cellular irradiation system has shown great potential to be a high temporal and spatial resolution research tool to enable researchers to gain a better understanding of the intricate cellular and intercellular microprocesses occurring following radiation deposition, which is essential to improving radiotherapy cancer treatment outcomes. In this paper, initial results of the system development are reported. The relationship between field emission current, the dose rate, and the dose distribution has been investigated. A beam size of 23 {mu}m has been achieved with variable dose rates of 1-100 Gy/s, and the system dosimetry has been measured using a radiochromic film. Cell irradiation has been demonstrated by the visualization of H2AX phosphorylation at DNA double-strand break sites following irradiation in a rat fibroblast cell monolayer. The prototype single beam cellular irradiator is a preliminary step to a multipixel cell irradiator that is under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Realization of polarization evolution on higher-order Poincaré sphere with metasurface

We present a simple and convenient method to yield cylindrical vector (CV) beams and realize its polarization evolution on higher-order Poincaré sphere based on inhomogeneous birefringent metasurface. By means of local polarization transformation of the metasurface, it is possible to convert a light beam with homogeneous elliptical polarization into a vector beam with any desired polarization distribution. The Stokes parameters of the output light are measured to verify our scheme, which show well agreement with the theoretical prediction. Our method may provide a convenient way to generate CV beams, which is expected to have potential applications in encoding information and quantum computation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CRADA Final Report CRADA No. LB05-001820"Ion Beam Drift Compression Technology for NDCX"

Summary of the specific research and project accomplishments: Through this collaboration, LBNL and FPSI determined the specific energy manipulations that apply to the Neutralized Drift Compression Experiment (NDCX) ion beam and developed the preliminary design of a Fast Induction Energy Corrector (FIEC). This effort was successfully completed, firmly establishing the technical feasibility of the proposed approach for regulating the longitudinal energy distribution of the NDCX ion beam. This is a critical step in achieving the NDCX goal of axial compression of the beam by a factor of 100 during neutralized drift.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quality Parameters of Zero-Order Bessel Light Beams

A collimated light beam at the output of a semiconductor laser module was studied experimentally. The intensity distribution in the transverse cross section of this beam did not have infinite-order axial symmetry and varied with the longitudinal coordinate. The experimental spatial intensity distributions in light fields formed by a conical lens (axicon) from radiation of He–Ne and semiconducting lasers were compared. Criteria were proposed for objective numerical quality assessment of zero-order Bessel light beams. The quality parameters of Bessel light fields formed by the axicon from radiation of He–Ne and semiconducting lasers were obtained from trial calculations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray FEL linear accelerator design via start-to-end global optimization

An X-ray Free Electron Laser (FEL) prefers using an electron beam with low emittance, small energy spread, and a high core current to generate coherent radiation through an undulator. In order to attain such a high brightness beam, the linear accelerator beam dynamics design generally involves separate photoinjector optimization and linac optimization. In this paper, we propose a new beam dynamics design strategy based on global optimization with fast start-to-end simulations from the photocathode to the end of the accelerator. The new start-to-end model significantly reduces the simulation time and makes the global optimization practical. The global optimization method avoids the need to choose a single solution based on bunch length at the injector exit for the linac optimization and helps find the solution with unfavorable bunch length at the injector exit but better phase space distribution that can result in better final electron beam phase space distribution at the entrance of the undulator. Here, using the start-to-end global optimization, we showed in an application example, with a 100 pC beam that good transverse emittance and over kilo-Ampere final core current can be attained using a photoinjector that consists of a VHF gun and boosting RF cavities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser plasma in a magnetic field

Laser ion source (LIS) is a candidate among various heavy ion sources. A high density plasma produced by Nd:yttrium aluminum garnet laser with drift velocity realizes high current and high charge state ion beams. In order to obtain higher beam current, we made experiments using the LIS with a magnetic field by which a confinement effect can make higher beam current. We measured total current by Faraday cup and analyzed charge distribution by electrostatic ion analyzer. It is shown that the ion beam charge state is higher by a permanent magnet.

43 PARTICLE ACCELERATORS↗

Ion recombination correction in carbon ion beams

Purpose: In this work, ion recombination is studied as a function of energy and depth in carbon ion beams. Methods: Measurements were performed in three different passively scattered carbon ion beams with energies of 62 MeV/n, 135 MeV/n, and 290 MeV/n using various types of plane-parallel ionization chambers. Experimental results were compared with two analytical models for initial recombination. One model is generally used for photon beams and the other model, developed by Jaffé, takes into account the ionization density along the ion track. An investigation was carried out to ascertain the effect on the ion recombination correction with varying ionization chamber orientation with respect to the direction of the ion tracks. The variation of the ion recombination correction factors as a function of depth was studied for a Markus ionization chamber in the 62 MeV/n nonmodulated carbon ion beam. This variation can be related to the depth distribution of linear energy transfer. Results: Results show that the theory for photon beams is not applicable to carbon ion beams. On the other hand, by optimizing the value of the ionization density and the initial mean-square radius, good agreement is found between Jaffé’s theory and the experimental results. As predicted by Jaffé’s theory, the results confirm that ion recombination corrections strongly decrease with an increasing angle between the ion tracks and the electric field lines. For the Markus ionization chamber, the variation of the ion recombination correction factor with depth was modeled adequately by a sigmoid function, which is approximately constant in the plateau and strongly increasing in the Bragg peak region to values of up to 1.06. Except in the distal edge region, all experimental results are accurately described by Jaffé’s theory. Conclusions: Experimental results confirm that ion recombination in the investigated carbon ion beams is dominated by initial recombination. Ion recombination corrections are found to be significant and cannot be neglected for reference dosimetry and for the determination of depth dose curves in carbon ion beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HZE beam transport in multilayered materials

A nonperturbative analytic solution of the high charge and energy (HZE) Green's function is used to implement a computer code for laboratory ion beam transport in multiple-layered materials. The code is established to operate on the Langley nuclear fragmentation model used in space engineering applications. Computational procedures are established to generate linear energy transfer (LET) distributions for a specified ion beam and target for comparison with experimental measurement. Comparison with Fe-56 ion with Pb-Al and Pb-(CH2)(x) targets shows reasonable agreement.

Shinn, J. L.↗

HZE beam transport in multilayered materials

A nonperturbative analytic solution of the high charge and energy (HZE) Green's function is used to implement a computer code for laboratory ion beam transport in multiple-layered materials. The code is established to operate on the Langley nuclear fragmentation model used in space engineering applications. Computational procedures are established to generate linear energy transfer (LET) distributions for a specified ion beam and target for comparison with experimental measurement. Comparison with 56Fe ion with Pb-Al and Pb-(CH2)x targets shows reasonable agreement.

NASA Discipline Radiation Health↗

NASA’s Galactic Cosmic Ray Simulator at Brookhaven National Laboratory: Enabling Human Exploration Missions to the Moon and Mars

With exciting new Agency plans for a sustainable return to the moon, astronauts will once again leave earth’s protective magnetosphere only to endure higher levels of radiation from galactic cosmic rays (GCR) and the possibility of a large solar particle event (SPE). Gateway, lunar landers, and surface habitats will be designed to protect crew against SPE’s with vehicle optimization, storm shelter concepts, and/or active dosimetry; however, the ever-penetrating GCR will continue to pose the most significant health risks especially as lunar missions increase in duration and as NASA sets its aspirations on Mars. The primary risks of concern include epithelial carcinogenesis and leukemia, central nervous system effects resulting in potential in-mission cognitive or behavioral impairment and/or late neurological disorders, degenerative tissue effects including cataracts, circulatory and heart disease, as well as, potential immune system decrements impacting multiple aspects of crew health. Characterization and mitigation of these risks requires a significant reduction in the large biological uncertainties of chronic (low-dose rate) heavy ion exposures and the validation of countermeasures in a relevant space environment. NASA has developed the “GCR Simulator” at Brookhaven National Laboratory to generate a spectrum of ion beams that approximates the primary and secondary GCR field experienced at human organ locations within a deep-space vehicle. The majority of the dose is delivered from protons (~65-75%) and alpha particles (~10-20%) with heavier ions (Z≤3) contributing the remainder. The “GCR Simulator” exposes state-of-the art cellular and animal model systems to 33 sequential beams including 4 proton energies plus degrader, 4 helium energies plus degrader, and the five heavy ions of C, O, Si, Ti, and Fe. A polyethylene degrader is used with the 100 MeV/n H and He beams to provide a nearly continuous distribution of low energy particles. A 500 mGy exposure, delivering doses from each of the 33 beams, requires 75-90 minutes. To more closely simulate the low dose rates found in space, sequential field exposures can be divided into daily fractions over 2-4 weeks, with individual fractions as low as 0.1-0.2 mGy. In the large beam configuration (60 x 60 cm(exp 2)), 54 special housing cages can accommodate 2-3 mice each for a 70-75 min duration or ~15 individually housed rats. Emerging research results from our 2018 runs utilizing mixed heavy ion fields and protracted space exposures are forthcoming and deepen our understanding of the numerous health risks faced by our astronauts. This paper discusses NASA’s innovative technology solution for a ground-based GCR simulator at the NASA Space Radiation Laboratory to enable future exploration missions.

Lisa C Simonsen↗

NASA Space Radiation Laboratory Galactic Cosmic Ray Simulator

With exciting new Agency plans for a sustainable return to the moon, astronauts will once again leave earth’s protective magnetosphere only to endure higher levels of radiation from galactic cosmic rays (GCR) and the possibility of a large solar particle event (SPE). Gateway, lunar landers, and surface habitats will be designed to protect crew against SPEs with vehicle optimization, storm shelter concepts, and/or active dosimetry; however, the ever-penetrating GCR will continue to pose the most significant health risks especially as lunar missions increase in duration and as NASA sets its aspirations on Mars. The primary risks of concern include carcinogenesis, central nervous system effects resulting in potential in-mission cognitive or behavioral impairment and/or late neurological disorders, degenerative tissue effects including cataracts, circulatory and heart disease, as well as, potential immune system decrements impacting multiple aspects of crew health. Characterization and mitigation of these risks requires a significant reduction in the large biological uncertainties of chronic (low-dose rate) heavy ion exposures and the validation of countermeasures in a relevant space environment. NASA has developed the “GCR Simulator” at Brookhaven National Laboratory to generate a spectrum of ion beams that approximates the primary and secondary GCR field experienced at human organ locations within a deep-space vehicle. The majority of the dose is delivered from protons (~65-75%) and helium ions (~10-20%) with heavier ions (Z>3) contributing the remainder. The “GCR Simulator” exposes state-of-the art cellular and animal model systems to 33 sequential beams including 4 proton energies plus degrader, 4 helium energies plus degrader, and the five heavy ions of C, O, Si, Ti, and Fe. A polyethylene degrader is used with the 100 MeV/n H and He beams to provide a nearly continuous distribution of low energy particles. A 500 mGy exposure, delivering doses from each of the 33 beams, requires 75-90 minutes. To more closely simulate the low dose rates found in space, sequential field exposures can be divided into daily fractions over 2-6 weeks, with individual beam fractions as low as 0.1-0.2 mGy. In the large beam configuration (60 x 60 cm2), 54 special housing cages can accommodate 2-3 mice each for a 70-75 min duration or ~15 individually housed rats. Emerging research results from our 2018 runs utilizing mixed heavy ion fields and protracted space exposures are forthcoming and will deepen our understanding of the numerous health risks faced by astronauts. This talk discusses NASA’s innovative technology solution for a ground-based GCR simulator at the NASA Space Radiation Laboratory to enable future exploration missions.

galactic cosmic ray simulator↗

A dynamic collimation system for penumbra reduction in spot-scanning proton therapy: Proof of concept

Purpose: In the absence of a collimation system the lateral penumbra of spot scanning (SS) dose distributions delivered by low energy proton beams is highly dependent on the spot size. For current commercial equipment, spot size increases with decreasing proton energy thereby reducing the benefit of the SS technique. This paper presents a dynamic collimation system (DCS) for sharpening the lateral penumbra of proton therapy dose distributions delivered by SS. Methods: The collimation system presented here exploits the property that a proton pencil beam used for SS requires collimation only when it is near the target edge, enabling the use of trimmers that are in motion at times when the pencil beam is away from the target edge. The device consists of two pairs of parallel nickel trimmer blades of 2 cm thickness and dimensions of 2 cm × 18 cm in the beam's eye view. The two pairs of trimmer blades are rotated 90° relative to each other to form a rectangular shape. Each trimmer blade is capable of rapid motion in the direction perpendicular to the central beam axis by means of a linear motor, with maximum velocity and acceleration of 2.5 m/s and 19.6 m/s{sup 2}, respectively. The blades travel on curved tracks to match the divergence of the proton source. An algorithm for selecting blade positions is developed to minimize the dose delivered outside of the target, and treatment plans are created both with and without the DCS. Results: The snout of the DCS has outer dimensions of 22.6 × 22.6 cm{sup 2} and is capable of delivering a minimum treatment field size of 15 × 15 cm{sup 2}. Using currently available components, the constructed system would weigh less than 20 kg. For irregularly shaped fields, the use of the DCS reduces the mean dose outside of a 2D target of 46.6 cm{sup 2} by approximately 40% as compared to an identical plan without collimation. The use of the DCS increased treatment time by 1–3 s per energy layer. Conclusions: The spread of the lateral penumbra of low-energy SS proton treatments may be greatly reduced with the use of this system at the cost of only a small penalty in delivery time.

07 ISOTOPE AND RADIATION SOURCES↗

Three-dimensional imaging of the ultracold plasma formed in a supersonic molecular beam

Double-resonant excitation of nitric oxide in a seeded supersonic molecular beam forms a state-selected Rydberg gas that evolves to form an ultracold plasma. This plasma travels with the propagation of the molecular beam in z over a variable distance as great as 600 mm to strike an imaging detector, which records the charge distribution in the dimensions, x and y. The ω{sub 1} + ω{sub 2} laser crossed molecular beam excitation geometry convolutes the axial Gaussian distribution of NO in the molecular beam with the Gaussian intensity distribution of the perpendicularly aligned laser beam to create an ellipsoidal volume of Rydberg gas. Detected images describe the evolution of this initial density as a function of selected Rydberg gas initial principal quantum number, n{sub 0}, ω{sub 1} laser pulse energy (linearly related to Rydberg gas density, ρ{sub 0}) and flight time. Low-density Rydberg gases of lower principal quantum number produce uniformly expanding, ellipsoidal charge-density distributions. Increase either of n{sub 0} or ρ{sub 0} breaks the ellipsoidal symmetry of plasma expansion. The volume bifurcates to form repelling plasma volumes. The velocity of separation depends on n{sub 0} and ρ{sub 0} in a way that scales uniformly with ρ{sub e}, the density of electrons formed in the core of the Rydberg gas by prompt Penning ionization. Conditions under which this electron gas drives expansion in the long axis dimension of the ellipsoid favours the formation of counter-propagating shock waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Angular distribution of neutron production by proton and carbon-ion therapeutic beams

Carbon-ion beams are increasingly used in the clinical practice for external radiotherapy treatments of deep-seated tumors. At therapeutic energies, carbon ions yield significant secondary products, including neutrons, which may be of concern for the radiation protection of the patient and personnel. We simulated the neutron yield produced by proton and carbon-ion pencil beams impinging on a clinical phantom at three different angles: 15°, 45° and 90°, with respect to the beam axis. We validated the simulated results using the measured response of organic scintillation detectors. We compared the results obtained with FLUKA 2011.2 and MCNPX 2.7.0 based on three different physics models: Bertini, Isabel, and CEM. Over the different ions, energies, and angles, the FLUKA simulation results agree better with the measured data, compared to the MCNPX results. Simulations of carbon ions at low angles exhibit both the highest deviation from measured data and inter-model discrepancy, which is probably due to the different treatment of the pre-equilibrium stage. The reported neutron yield results could help in the comparison of carbon-ion and proton treatments in terms of secondary neutron production for radiation protection applications.

60 APPLIED LIFE SCIENCES↗