Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Computer simulation of the effects of transmission-averaging in microdensitometry

One of the principal advantages of electrography when compared to photography is the nearly linear relationship between source intensity versus resulting image density. This property allows for simplified and more accurate photometric calibration and permits a certain degree of extrapolation of the calibration to beyond the limits of the faintest photoelectric standard on an exposure. The desires to extract quantitative photometric information from electrographic (or photographic) negatives and to convert this information into a digital format for computer analysis or enhancement led to the widespread use of scanning microdensitometers to perform this A-to-D conversion. Therefore it is of vital importance to understand and, if practical, to avoid any nonlinearities which may be introduced during microdensitometry of electrographic emulsions.

Heckathorn, H. M.↗

Adaptive wall research with two- and three-dimensional models in low speed and transonic tunnels

This paper summarises recent research at the University of Southampton into adaptive wall technology and outlines the direction of current efforts. The work is aimed at developing techniques for use in test sections where the top and bottom walls may be adjusted in single curvature. Wall streamlining eliminates, as far as experimentally possible, the top and bottom wall interference in low speed and transonic aerofoil testing. A streamlining technique has been developed for low speeds which allows the testing of swept wing panels in low interference environments. At higher speeds, a comparison of several two-dimensional transonic streamlining algorithms has been made and a technique for streamlining with a choked test section has also been developed. Three-dimensional work has mainly concentrated on tests of sidewall mounted half-wings and the development of the software packages required to assess interference and to adjust the flexible walls. It has been demonstrated that two-dimensional wall adaptation can significantly modify the level of wall interference around relatively large three-dimensional models. The residual interferences are small and are probably amenable to standard post-test correction methods. Tests on a calibrated wing-body model are planned in the near future to further validate the proposed streamlining technique.

Lewis, M. C.↗

Makeup and uses of a basic magnet laboratory for characterizing high-temperature permanent magnets

A set of instrumentation for making basic magnetic measurements was assembled in order to characterize high intrinsic coercivity, rare earth permanent magnets with respect to short term demagnetization resistance and long term aging at temperatures up to 300 C. The major specialized components of this set consist of a 13 T peak field, capacitor discharge pulse magnetizer; a 10 in. pole size, variable gap electromagnet; a temperature controlled oven equipped with iron cobalt pole piece extensions and a removable paddle that carries the magnetization and field sensing coils; associated electronic integrators; and sensor standards for field intensity H and magnetic moment M calibration. A 1 cm cubic magnet sample, carried by the paddle, fits snugly between the pole piece extensions within the electrically heated aluminum oven, where fields up to 3.2 T can be applied by the electromagnet at temperatures up to 300 C. A sample set of demagnetization data for the high energy Sm2Co17 type of magnet is given for temperatures up to 300 C. These data are reduced to the temperature dependence of the M-H knee field and of the field for a given magnetic induction swing, and they are interpreted to show the limits of safe operation.

Niedra, Janis M.↗

Ultrasonic pulsed phase locked loop interferometer for bolt load measurements

The pulsed phase-locked-loop bolt monitor (P2L2) that uses ultrasonic waves to measure bolt preload with accuracies ranging from 1 to 3 percent (depending on the specific bolt) is described. To remeasure bolt load after installation, a thermal calibration factor compensates for bolt temperature changes, and a standard reference block allows correction for acoustic phase errors due to measurement equipment configuration such as utilization of a different transducer, couplant, or cable. Some examples of critical applications including Space Shuttle landing-gear wheels and NASA wind-tunnel fan blades are discussed.

Allison, S. G.↗

An Automated Thermocouple Calibration System

An Automated Thermocouple Calibration System (ATCS) was developed for the unattended calibration of type K thermocouples. This system operates from room temperature to 650 C and has been used for calibration of thermocouples in an eight-zone furnace system which may employ as many as 60 thermocouples simultaneously. It is highly efficient, allowing for the calibration of large numbers of thermocouples in significantly less time than required for manual calibrations. The system consists of a personal computer, a data acquisition/control unit, and a laboratory calibration furnace. The calibration furnace is a microprocessor-controlled multipurpose temperature calibrator with an accuracy of +/- 0.7 C. The accuracy of the calibration furnace is traceable to the National Institute of Standards and Technology (NIST). The computer software is menu-based to give the user flexibility and ease of use. The user needs no programming experience to operate the systems. This system was specifically developed for use in the Microgravity Materials Science Laboratory (MMSL) at the NASA LeRC.

Bethea, Mark D.↗

Evaluation of dual-tip micromanometers during 21-day implantation in goats

Investigative research efforts using a cardiovascular model required the determination of central circulatory haemodynamic and arterial system parameters for the evaluation of cardiovascular performance. These calculations required continuous beat-to-beat measurement of pressure within the four chambers of the heart and great vessels. Sensitivity and offset drift, longevity, and sources of error for eight 3F dual-tipped micromanometers were determined during 21 days of implantation in goats. Subjects were instrumented with pairs of chronically implanted fluid-filled access catheters in the left and right ventricles, through which dual-tipped (test) micromanometers were chronically inserted and single-tip (standard) micromanometers were acutely inserted. Acutely inserted sensors were calibrated daily and measured pressures were compared in vivo to the chronically inserted sensors. Comparison of the pre- and post-gain calibration of the chronically inserted sensors showed a mean sensitivity drift of 1.0 +/- 0.4% (99% confidence, n = 9 sensors) and mean offset drift of 5.0 +/- 1.5 mmHg (99% confidence, n = 9 sensors). Potential sources of error for these drifts were identified, and included measurement system inaccuracies, temperature drift, hydrostatic column gradients, and dynamic pressure changes. Based upon these findings, we determined that these micromanometers may be chronically inserted in high-pressure chambers for up to 17 days with an acceptable error, but should be limited to acute (hours) insertions in low-pressure applications.

Non-NASA Center↗

Monochromatic Measurements of the JPSS-1 VIIRS Polarization Sensitivity

Polarization sensitivity is a critical property that must be characterized for spaceborne remote sensing instruments designed to measure reflected solar radiation. Broadband testing of the first Joint Polar-orbiting Satellite System (JPSS-1) Visible Infrared Imaging Radiometer Suite (VIIRS) showed unexpectedly large polarization sensitivities for the bluest bands on VIIRS (centered between 400 and 600 nm). Subsequent ray trace modeling indicated that large diattenuation on the edges of the bandpass for these spectral bands was the driver behind these large sensitivities. Additional testing using the National Institute of Standards and Technologies Traveling Spectral Irradiance and Radiance Responsivity Calibrations Using Uniform Sources was added to the test program to verify and enhance the model. The testing was limited in scope to two spectral bands at two scan angles; nonetheless, this additional testing provided valuable insight into the polarization sensitivity. Analysis has shown that the derived diattenuation agreed with the broadband measurements to within an absolute difference of about0.4 and that the ray trace model reproduced the general features of the measured data. Additionally, by deriving the spectral responsivity, the linear diattenuation is shown to be explicitly dependent on the changes in bandwidth with polarization state.

Monochromatic↗

SNPP VIIRS RSB Earth View Reflectance Uncertainty

The Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership (SNPP) satellite uses its 14 reflective solar bands to passively collect solar radiant energy reflected off the Earth. The Level 1 product is the geolocated and radiometrically calibrated top-of- the-atmosphere solar reflectance. The absolute radiometric uncertainty associated with this product includes contributions from the noise associated with measured detector digital counts and the radiometric calibration bias. Here, we provide a detailed algorithm for calculating the estimated standard deviation of the retrieved top-of-the-atmosphere spectral solar radiation reflectance.

VIIRS↗

Determination of Ballistic Limit for IM7/8552 Using LS-DYNA MAT 261

The goal of the NASA ACC High Energy Dynamic Impact Project is to determine the state of the art of dynamic fracture simulations for high velocity impact for composite fuselage shielding applications. Using a building block approach, several computational models considered under NASA ACC are being validated against test data, starting at unconfigured panels and progressing to configured panels under combined out-of-plane and in-plane loading due to ballistic impact. The computational models being evaluated in this project include MAT 162, MAT 213, MAT 261, SPG, and Peridynamics. In this paper, the simulation results using LS-Dyna Material MAT 261 are presented. In particular, a series of blind predictions for unconfigured panels were performed to determine the ballistic limit or V50 velocity. MAT 261 employs failure approach that is generally physically-based using fracture toughness criteria. The overall material model relies on typical ply-level stiffness properties, similar to MAT 162 and other composite continuum damage material models. The fracture toughness values are based on standard tests, and thus are not subject to extensive calibration. This approach is more efficient than performing extensive optimization studies for calibration of parameters. Also, this approach of relying on physical properties reduces the uncertainty of results, as questions concerning the quality and extent of the calibration studies is no longer relevant. However, it was found that carefully controlled coupon-level tests are needed to accurately obtain the required fracture toughness values. Additionally, it should be noted that there is one significant parameter in MAT 261 that does appear to require calibration, and that is the overall failure strain. This is the strain at which the element is deleted, and is not the same as the strain at which damage begins to accumulate. This failure strain is termed EFS (Effective Failure Strain), and is the maximum effective stain for element failure. Simulations have shown that this value will significantly affect impact response and failure. The paper presents the effect of this element failure strain parameter, along with possible uncertainties in fracture toughness values. With an adjusted appropriate value for EFS, it is seen that simulation results compare well with impact test data for predicted penetration velocity.

Byar, Alan↗

Development of Gas Analysis Capabilities

Project Description: The project objective was to develop gas analysis methodology and processes to identify and quantify contaminants specific to KSC, primarily volatile organic compounds (VOCs), utilizing the recently purchased gas chromatograph-mass spectrometer (GCMS) coupled with a sample pre-concentrator. This work established a standing, quick-turnaround quantitative GCMS methodology for KSC-specific VOCs associated with launching and landing spacecraft at trace-levels far below previous detection limits. Closeout Summary: This project established a standing methodology for rapid turnaround identification and quantification of 119 targeted VOCs considered most likely to be encountered at KSC. Of these, 111 of the calibration files are based on manufacturer-certified gas standard mixes. The other eight were generated using standards generated in-house from neat, certified reference materials using procedures for standard generation that were developed under this project. Additionally, the spectral signatures of two hydrofluorocarbon precision cleaning solvents, that are widely used in flight hardware processing, have been added to the mass spectral library for rapid qualitative identification.

Cristina Oropeza↗

Chapter 7: Sun Photometers

Sun photometry is an extended technique for monitoring the atmospheric composition and support satellite product validation. By measuring the direct solar irradiance, the amount and characteristics of the atmospheric aerosol particles, precipitable water vapor column, and ozone columns can be derived. Global operational networks such as the Aerosol Robotic Network (AERONET), Global Atmosphere Watch-Precision Filter Radiometer Network (GAW-PFR), Maritime Aerosol Network (MAN), or the Brewer spectrophotometer networks constitute sustained efforts for long-term monitoring of the atmosphere, with invaluable data production using cost-effective and relatively simple instrumentation. The data quality relies on the standardization of these networks, with special emphasis on the calibration as the key element in Sun photometry.

Sun photometry↗

Benefits of the Multiple Echo Technique for Ultrasonic Thickness Testing

Much effort has been put into determining methods to make accurate thickness measurements, especially at elevated temperatures. An accuracy of +/- 0.001 inches is typically noted for commercial ultrasonic thickness gauges and ultrasonic thickness techniques. Codes and standards put limitations on many inspection factors including equipment, calibration tolerance and temperature variations. These factors are important and should be controlled, but unfortunately do not guarantee accurate and repeatable measurements in the field. Most technicians long for a single technique that is best for every situation, unfortunately, there are no 'silver bullets' when it comes to nondestructive testing. This paper will describe and discuss some of the major contributors to measurement error as well as some advantages and limitations of multiple echo techniques and why multiple echo techniques should be more widely utilized for ultrasonic thickness measurements.

42 ENGINEERING↗

Production of Xenon-135 from isotopically enriched Xenon-134 and Xenon-136 Targets

Atmospheric radioxenon analyses conducted under the Comprehensive Test Ban Treaty Organization (CTBTO) necessitates the collection and analysis of air samples to quantify 135Xe, an indicator for nuclear explosions and reactor operations. Analytical instrument calibration for these analyses requires high quality, monoisotopic reference standards that are typically short lived, and therefore must be produced and shipped promptly to monitoring stations worldwide. This work describes the preparation of 135Xe by neutron capture (n, ?) on monoisotopic 134Xe, neutron irradiation (n,2n) on monoisotopic 136Xe, and high energy photon irradiation (?, n) on monoisotopic 136Xe. The targets are prepared by electromagnetic isotope separation of natural xenon. Results from each process are compared for 135Xe yield and purity.

07 ISOTOPE AND RADIATION SOURCES↗

Comparison of Activity Determination of Radium 226 in FUSRAP Soil using Various Energy Lines - 12299

Gamma spectroscopy is used at the Formerly Utilized Sites Remedial Action Program (FUSRAP) Maywood Superfund Site as the primary radioanalytical tool for quantization of activities of the radionuclides of concern in site soil. When selecting energy lines in gamma spectroscopy, a number of factors are considered including assumptions concerning secondary equilibrium, interferences, and the strength of the lines. The case of the Maywood radionuclide of concern radium-226 (Ra-226) is considered in this paper. At the FUSRAP Maywood Superfund Site, one of the daughters produced from radioactive decay of Ra-226, lead-214 (Pb- 214), is used to quantitate Ra-226. Another Ra-226 daughter, bismuth-214 (Bi-214), also may be used to quantitate Ra-226. In this paper, a comparison of Ra-226 to Pb-214 activities and Ra-226 to Bi-214 activities, obtained using gamma spectrometry for a large number of soil samples, was performed. The Pb-214, Bi-214, and Ra-226 activities were quantitated using the 352 kilo electron volt (keV), 609 keV, and 186 keV lines, respectively. The comparisons were made after correcting the Ra-226 activities by a factor of 0.571 and both ignoring and accounting for the contribution of a U-235 interfering line to the Ra-226 line. For the Pb-214 and Bi-214 activities, a mean in-growth factor was employed. The gamma spectrometer was calibrated for efficiency and energy using a mixed gamma standard and an energy range of 59 keV to 1830 keV. The authors expect other sites with Ra-226 contamination in soil may benefit from the discussions and points in this paper. Proper use of correction factors and comparison of the data from three different gamma-emitting radionuclides revealed agreement with expectations and provided confidence that using such correction factors generates quality data. The results indicate that if contamination is low level and due to NORM, the Ra-226 can be measured directly if corrected to subtract the contribution from U-235. If there is any indication that technologically enhanced uranium may be present, the preferred measurement approach for quantitation of Ra-226 activity is detection of one of the Ra-226 daughters, Pb-214 or Bi-214, using a correction factor obtained from an in-growth curve. The results also show that the adjusted Ra-226 results compare very well with both the Pb-214 and Bi-214 results obtained using an in-growth curve correction factor. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hexavalent chromium sensor for real-time In situ measurement of ground water contamination - 15433

Hexavalent chromium (Cr{sup 6+}) is a contaminant of concern at multiple Department of Energy (DOE) and industrial sites across the United States. It is used in stainless steel production, textile dyes, tanning, wood preservation, and in conversion coatings. It was used at DOE sites, such as the Hanford Nuclear Reservation in Washington state, in the form sodium dichromate (Na{sub 2}Cr{sub 2}O{sub 7}) to inhibit corrosion. This has resulted in the release of chromate (CrO{sub 4}{sup 2-}) to groundwater. Chromate is anionic and is readily transported with ground water through the subsurface to receptors such as river biota at Hanford, and in some regions to potable water wells. To improve Cr{sup 6+} groundwater plume monitoring while reducing monitoring cost, a cable-deployed, submersible sensor was developed for direct measurements of Cr{sup 6+} in natural groundwater. With a diameter of 3.8 cm (1.5 inch) the sensor could be deployed in 5 cm (2 inch) diameter screened wells. The sensor uses ultra violet (UV) photo-spectroscopy to measure Cr{sup 6+} at concentrations as low as 5 to 10 μg L{sup -1} (as hexavalent chromium, Cr{sup +6}) in natural water. Turbidity, caused by colloidal material suspended in natural water, can interfere with the chromate measurement but was automatically compensated within the instrument. Because the instrument had some temperature sensitivity, a correction was also applied based on in situ temperature measurements in the sensor. The sensor has been tested in the laboratory and was deployed to the field with encouraging results. Laboratory calibrations consistently yielded concentration measurements that correlate well with standard analytical methods (r{sup 2} = 0.99). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Selective Determination of Methylmercury Levels in Mercury-Contaminated Topsoils from Oak Ridge, TN - 18163

Mercury (Hg) is a strong neurotoxin that affects the central and peripheral nervous system. Mercury has several organomercury species that bio-accumulate in many different environments. In early 1950's, elemental mercury was used for manufacturing of various components nuclear weapons systems in the Y-12 Security Complex in Oak Ridge, TN. The mercury released to the environment contaminated the facilities, soil, sediment, surface water, and groundwater within the boundaries of the Y-12 Plant and the downstream environment along the East Fork Poplar Creek. Remediation efforts have been made since then to alleviate the amount of mercury contamination that impacts the soil, water and wildlife at the Y-12 complex and surrounding areas. Yet, mercury levels in the water still exceed both the regulatory limits (51 ng/L) and the remediation goal (200 μg/L). Methylmercury (CH{sub 3}Hg) is the most toxic form of mercury that bio-accumulates exponentially compared to other forms of mercury. It is hypothesized that contaminated soils contain significant levels of methylmercury that contributes to contamination in nearby freshwater ecosystems in Y-12 complex. The objective of this study was to develop analytical method for selective determination of CH{sub 3}Hg from mercury-contaminated soils that contained elevated levels of inorganic mercury, Hg(II). Attempts were made to selectively extract CH{sub 3}Hg from spiked template soils via extraction in dilute hydrochloric (HCl) and nitric acids (HNO{sub 3}). The latter performed better than HCl affording quantitative extraction of CH{sub 3}Hg with minimal extraction of Hg(II). Under same circumstance, only about 5% of Hg(II) extracted from the soil matrix. Coprecipitation efforts were made using Bi(III), Fe(III) and La(III) alone and in conjunction with thiourea and L-cysteine. A combination of La(III) + L-cysteine afforded highest elimination of Hg(II) from solutions. Thiourea was not suitable for coprecipitation of Hg(II) as it also precipitated up to 67% of CH{sub 3}Hg from simulated soil solutions. Cold vapor generation (CVG) interfaced to ICP-MS was optimized for selective determination of CH{sub 3}Hg{sup +}. Calibration curves were established with CH{sub 3}Hg standards in La(III) and 0.1% L-cysteine and 5% (v/v) HNO{sub 3} by CVG-ICP-MS. The method was validated by determination of CH{sub 3}Hg in sediment reference material (SQC1238) and Estuarine sediment (ERM - CC580) containing trace levels of CH{sub 3}Hg in Hg(II) matrix. The procedure was applied to floodplain soils from Oak Ridge, TN. Methylmercury levels were in the range of 0.031 to 0.047 μg/g. The results indicated that CH{sub 3}Hg{sup +} levels were substantially lower inorganic Hg(II), still though CH{sub 3}Hg at these levels could be significant source of persistent mercury contamination in freshwater systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Calibrated Noise Measurements with Induced Receiver Gain Fluctuations

The lack of well-developed techniques for modeling changing statistical moments in our observations has stymied the application of stochastic process theory in science and engineering. These limitations were encountered when modeling the performance of radiometer calibration architectures and algorithms in the presence of non stationary receiver fluctuations. Analyses of measured signals have traditionally been limited to a single measurement series. Whereas in a radiometer that samples a set of noise references, the data collection can be treated as an ensemble set of measurements of the receiver state. Noise Assisted Data Analysis is a growing field of study with significant potential for aiding the understanding and modeling of non stationary processes. Typically, NADA entails adding noise to a signal to produce an ensemble set on which statistical analysis is performed. Alternatively as in radiometric measurements, mixing a signal with calibrated noise provides, through the calibration process, the means to detect deviations from the stationary assumption and thereby a measurement tool to characterize the signal's non stationary properties. Data sets comprised of calibrated noise measurements have been limited to those collected with naturally occurring fluctuations in the radiometer receiver. To examine the application of NADA using calibrated noise, a Receiver Gain Modulation Circuit (RGMC) was designed and built to modulate the gain of a radiometer receiver using an external signal. In 2010, an RGMC was installed and operated at the National Institute of Standards and Techniques (NIST) using their Noise Figure Radiometer (NFRad) and national standard noise references. The data collected is the first known set of calibrated noise measurements from a receiver with an externally modulated gain. As an initial step, sinusoidal and step-function signals were used to modulate the receiver gain, to evaluate the circuit characteristics and to study the performance of a variety of calibration algorithms. The receiver noise temperature and time-bandwidth product of the NFRad are calculated from the data. Statistical analysis using temporal-dependent calibration algorithms reveals that the natural occurring fluctuations in the receiver are stationary over long intervals (100s of seconds); however the receiver exhibits local non stationarity over the interval over which one set of reference measurements are collected. A variety of calibration algorithms have been applied to the data to assess algorithms' performance with the gain fluctuation signals. This presentation will describe the RGMC, experiment design and a comparative analysis of calibration algorithms.

Racette, Paul↗

An accurate online calibration system based on combined clamp-shape coil for high voltage electronic current transformers

Electronic transformers are widely used in power systems because of their wide bandwidth and good transient performance. However, as an emerging technology, the failure rate of electronic transformers is higher than that of traditional transformers. As a result, the calibration period needs to be shortened. Traditional calibration methods require the power of transmission line be cut off, which results in complicated operation and power off loss. This paper proposes an online calibration system which can calibrate electronic current transformers without power off. In this work, the high accuracy standard current transformer and online operation method are the key techniques. Based on the clamp-shape iron-core coil and clamp-shape air-core coil, a combined clamp-shape coil is designed as the standard current transformer. By analyzing the output characteristics of the two coils, the combined clamp-shape coil can achieve verification of the accuracy. So the accuracy of the online calibration system can be guaranteed. Moreover, by employing the earth potential working method and using two insulating rods to connect the combined clamp-shape coil to the high voltage bus, the operation becomes simple and safe. Tests in China National Center for High Voltage Measurement and field experiments show that the proposed system has a high accuracy of up to 0.05 class.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗