Search NASA⌕ Search

SEARCH · Search NASA

Results for “CASE STUDY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Case studies of NOAA 6/TIROS N data impact on numerical weather forecasts

The impact of satellite temperatures from systems which predate the launching of the third generation of vertical sounding instruments aboard TIROS N (13 Oct 1978) and NOAA 6 (27 June 1979) is reported. The first evaluation of soundings from TIROS N found that oceanic, cloudy retrievals over NH mid latitudes show a cold bias in winter. It is confirmed for both satellite systems using a larger data base. It is shown that RMS differences between retrievals and colocated radiosonde observations within the swath 30-60N during the 1979-80 winter were generally 2-3K in clear air and higher for cloudy columns. A positive impact of TIROS N temperatures on the analysis of synoptic weather systems is shown. Analyses prepared from only satellite temperatures seemed to give a better definition to weather systems' thermal structure than that provided by corresponding NMC analyses without satellite data. The results of a set of 14 numerical forecast experiments performed with the PE model of the Israel Meteorological Service (IMS) are summarized; these were designed to test the impact of TIROS N and NOAA 6 temperatures within the IMS analysis and forecast cycle. The satellite data coverage over the NH, the mean area/period S1 and RMS verification scores and the spatial distribution of SAT versus NO SAT forecast differences are discussed and it is concluded that positive forecast impact occurs over ocean areas where the extra data improve the specification which is otherwise available from conventional observations. The forecast impact for three cases from the same set of experiments was examined and it is found that satellite temperatures, observed over the Atlantic Ocean contribute to better forecasts over Iceland and central Europe although a worse result was verified over Spain. It is also shown that the better scores of a forecast based also on satellite data and verified over North America actually represent a mixed impact on the forecast synoptic patterns. A superior 48 hr 500 mb forecast over the western US due to the better initial specification afforded by satellite observed temperatures over the North Pacific Ocean is shown.

Druyan, L. M.↗

Size saturation in low energy ion beam synthesized nanoparticles in silica glass: 50 keV Ag{sup -} ions implantation, a case study

Fluence-dependent formation of Ag nanoparticles (NPs) in silica glass by 50 keV Ag{sup -} ions implantation has been studied. Samples implanted with fluences of 2x10{sup 16} ions cm{sup -2} and above are found to show an absorption band at around 410 nm, corresponding to the surface plasmon resonance (SPR) of the Ag NPs in silica glass. An increase in SPR peak intensity with increase in fluence has been observed up to a fluence of 7x10{sup 16} ions cm{sup -2} (F7), after which the absorption intensity shows a saturation. Simulations of the optical absorption spectra also indicated an increase in the absorption intensity and hence the size of the NPs with increase in fluence up to F7, beyond which NP size is seen to saturate. The saturation of fluence and the SPR intensity (or NP size) have been explained as coming due to a break up of larger Ag NPs formed near the surface by displacement spikes induced by subsequently incident Ag ions against their regrowth from the movement of Ag atoms toward the surface and their sputtering loss. Further, we have compared our observations with the earlier data on saturation of fluence and size of NPs in cases of Au and Zn, and concluded that the saturation of both fluence and NP size are general phenomena for low energy high fluence metal ion implantation.

36 MATERIALS SCIENCE↗

Methodology to design a municipal solid waste pre-collection system. A case study

Highlights: • MSW recovery starts at homes; therefore it is important to facilitate it to people. • Additionally, to optimize MSW collection a previous pre-collection must be planned. • A methodology to organize pre-collection considering several factors is presented. • The methodology has been verified applying it to a Spanish middle town. - Abstract: The municipal solid waste (MSW) management is an important task that local governments as well as private companies must take into account to protect human health, the environment and to preserve natural resources. To design an adequate MSW management plan the first step consists in defining the waste generation and composition patterns of the town. As these patterns depend on several socio-economic factors it is advisable to organize them previously. Moreover, the waste generation and composition patterns may vary around the town and over the time. Generally, the data are not homogeneous around the city as the number of inhabitants is not constant nor it is the economic activity. Therefore, if all the information is showed in thematic maps, the final waste management decisions can be made more efficiently. The main aim of this paper is to present a structured methodology that allows local authorities or private companies who deal with MSW to design its own MSW management plan depending on the available data. According to these data, this paper proposes two ways of action: a direct way when detailed data are available and an indirect way when there is a lack of data and it is necessary to take into account bibliographic data. In any case, the amount of information needed is considerable. This paper combines the planning methodology with the Geographic Information Systems to present the final results in thematic maps that make easier to interpret them. The proposed methodology is a previous useful tool to organize the MSW collection routes including the selective collection. To verify the methodology it has been successfully applied to a Spanish town.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Utilization of O4 Slant Column Density to Derive Aerosol Layer Height from a Space-Borne UV-Visible Hyperspectral Sensor: Sensitivity and Case Study

The sensitivities of oxygen-dimer (O4) slant column densities (SCDs) to changes in aerosol layer height are investigated using the simulated radiances by a radiative transfer model, the linearized pseudo-spherical vector discrete ordinate radiative transfer (VLIDORT), and the differential optical absorption spectroscopy (DOAS) technique. The sensitivities of the O4 index (O4I), which is defined as dividing O4 SCD by 10(sup 40) molecules (sup 2) per centimeters(sup -5), to aerosol types and optical properties are also evaluated and compared. Among the O4 absorption bands at 340, 360, 380, and 477 nanometers, the O4 absorption band at 477 nanometers is found to be the most suitable to retrieve the aerosol effective height. However, the O4I at 477 nanometers is significantly influenced not only by the aerosol layer effective height but also by aerosol vertical profiles, optical properties including single scattering albedo (SSA), aerosol optical depth (AOD), particle size, and surface albedo. Overall, the error of the retrieved aerosol effective height is estimated to be 1276, 846, and 739 meters for dust, non-absorbing, and absorbing aerosol, respectively, assuming knowledge on the aerosol vertical distribution shape. Using radiance data from the Ozone Monitoring Instrument (OMI), a new algorithm is developed to derive the aerosol effective height over East Asia after the determination of the aerosol type and AOD from the MODerate resolution Imaging Spectroradiometer (MODIS). About 80 percent of retrieved aerosol effective heights are within the error range of 1 kilometer compared to those obtained from the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) measurements on thick aerosol layer cases.

Air Pollution↗

How important is spatial resolution: Case studies at 48, 12 and 4 km for the U.S., Latin America and Southern Asia

A critical role for regional climate models is downscaling coarse spatial resolution global model simulations of climate change to the much higher resolution required for assessment of regional changes and impacts. But what degree of downscaling is required? Fully coupled global climate models typically have resolutions of at best 100-200 km. The most recent set of IPCC reports suggest that the scale of regional/local impacts to climate change are on the order of 10 km. The scale mismatch is obvious, but less clear is what degree the climate simulations must be downscaled to meet the needs of impacts studies - other non-climate factors might also be crucial or even dominant. We have made a series of simulations with the WRF ARW for the U.S., large portions of Latin America, and South and Southeast Asia. Each set of runs includes a large outer domain at 48 km; an intermediate domain at 12 km (that is the primary basis for model results and interpretations); and one or more 'exploratory' inner domains at 4 km. The latter include regions with complex topography as well as both homogeneous and inhomogeneous land surface types. For each region a multi-year control forced by NCEP reanalyses has been made. Experiments for Asia are focusing on the effects of deforestation, while those for the U.S. and Latin America are focusing on IPCC climate change scenarios (A1FI for the U.S. and A2 for Latin America). Large-scale forcings for the latter two are provided by NCAR CCSM IPCC AR4 simulations. Preliminary results suggest that the higher resolutions have much more structure in standard climate quantities such as temperature or precipitation. Less obvious, however, is how realistic these structures are. In some cases, they clearly follow the better resolution of topography; in other instances the reason is less certain. Furthermore, observational datasets are frequently inadequate in assessing realism, especially for the non-U.S. domains. Finally, this work raises the issue of the trade-off between the length and the resolution of regional climate model simulations. Which is more important - long runs at medium resolution, or shorter runs at higher resolution?

54 ENVIRONMENTAL SCIENCES↗

Methodology to design a municipal solid waste generation and composition map: A case study

Highlights: • To draw a waste generation and composition map of a town a lot of factors must be taken into account. • The methodology proposed offers two different depending on the available data combined with geographical information systems. • The methodology has been applied to a Spanish city with success. • The methodology will be a useful tool to organize the municipal solid waste management. - Abstract: The municipal solid waste (MSW) management is an important task that local governments as well as private companies must take into account to protect human health, the environment and to preserve natural resources. To design an adequate MSW management plan the first step consist in defining the waste generation and composition patterns of the town. As these patterns depend on several socio-economic factors it is advisable to organize them previously. Moreover, the waste generation and composition patterns may vary around the town and over the time. Generally, the data are not homogeneous around the city as the number of inhabitants is not constant nor it is the economic activity. Therefore, if all the information is showed in thematic maps, the final waste management decisions can be made more efficiently. The main aim of this paper is to present a structured methodology that allows local authorities or private companies who deal with MSW to design its own MSW management plan depending on the available data. According to these data, this paper proposes two ways of action: a direct way when detailed data are available and an indirect way when there is a lack of data and it is necessary to take into account bibliographic data. In any case, the amount of information needed is considerable. This paper combines the planning methodology with the Geographic Information Systems to present the final results in thematic maps that make easier to interpret them. The proposed methodology is a previous useful tool to organize the MSW collection routes including the selective collection. To verify the methodology it has been successfully applied to a Spanish town.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A FIRE-ACE/SHEBA Case Study of Mixed-Phase Arctic Boundary Layer Clouds: Entrainment Rate Limitations on Rapid Primary Ice Nucleation Processes

Observations of long-lived mixed-phase Arctic boundary layer clouds on 7 May 1998 during the First International Satellite Cloud Climatology Project (ISCCP) Regional Experiment (FIRE)Arctic Cloud Experiment (ACE)Surface Heat Budget of the Arctic Ocean (SHEBA) campaign provide a unique opportunity to test understanding of cloud ice formation. Under the microphysically simple conditions observed (apparently negligible ice aggregation, sublimation, and multiplication), the only expected source of new ice crystals is activation of heterogeneous ice nuclei (IN) and the only sink is sedimentation. Large-eddy simulations with size-resolved microphysics are initialized with IN number concentration N(sub IN) measured above cloud top, but details of IN activation behavior are unknown. If activated rapidly (in deposition, condensation, or immersion modes), as commonly assumed, IN are depleted from the well-mixed boundary layer within minutes. Quasi-equilibrium ice number concentration N(sub i) is then limited to a small fraction of overlying N(sub IN) that is determined by the cloud-top entrainment rate w(sub e) divided by the number-weighted ice fall speed at the surface v(sub f). Because w(sub c)< 1 cm/s and v(sub f)> 10 cm/s, N(sub i)/N(sub IN)<< 1. Such conditions may be common for this cloud type, which has implications for modeling IN diagnostically, interpreting measurements, and quantifying sensitivity to increasing N(sub IN) (when w(sub e)/v(sub f)< 1, entrainment rate limitations serve to buffer cloud system response). To reproduce observed ice crystal size distributions and cloud radar reflectivities with rapidly consumed IN in this case, the measured above-cloud N(sub IN) must be multiplied by approximately 30. However, results are sensitive to assumed ice crystal properties not constrained by measurements. In addition, simulations do not reproduce the pronounced mesoscale heterogeneity in radar reflectivity that is observed.

Fridlin, Ann↗

Common Cause Case Study: An Estimated Probability of Four Solid Rocket Booster Hold-Down Post Stud Hang-ups

Until Solid Rocket Motor ignition, the Space Shuttle is mated to the Mobil Launch Platform in part via eight (8) Solid Rocket Booster (SRB) hold-down bolts. The bolts are fractured using redundant pyrotechnics, and are designed to drop through a hold-down post on the Mobile Launch Platform before the Space Shuttle begins movement. The Space Shuttle program has experienced numerous failures where a bolt has hung up. That is, it did not clear the hold-down post before liftoff and was caught by the SRBs. This places an additional structural load on the vehicle that was not included in the original certification requirements. The Space Shuttle is currently being certified to withstand the loads induced by up to three (3) of eight (8) SRB hold-down experiencing a "hang-up". The results of loads analyses performed for (4) stud hang-ups indicate that the internal vehicle loads exceed current structural certification limits at several locations. To determine the risk to the vehicle from four (4) stud hang-ups, the likelihood of the scenario occurring must first be evaluated. Prior to the analysis discussed in this paper, the likelihood of occurrence had been estimated assuming that the stud hang-ups were completely independent events. That is, it was assumed that no common causes or factors existed between the individual stud hang-up events. A review of the data associated with the hang-up events, showed that a common factor (timing skew) was present. This paper summarizes a revised likelihood evaluation performed for the four (4) stud hang-ups case considering that there are common factors associated with the stud hang-ups. The results show that explicitly (i.e. not using standard common cause methodologies such as beta factor or Multiple Greek Letter modeling) taking into account the common factor of timing skew results in an increase in the estimated likelihood of four (4) stud hang-ups of an order of magnitude over the independent failure case.

Cross, Robert↗

A Case Study of Tunable White LED Lighting with Networked Lighting Controls (Emory University Cognitive Empowerment Program)

Emory University and Georgia Institute of Technology (Georgia Tech) partnered to create the Charlie and Harriet Schaffer Cognitive Empowerment Program (CEP) facility in northeast Atlanta. Together with the funders they are building a program to help individuals experiencing mild cognitive impairment (MCI) to maintain their physical and cognitive health, and independence as long as possible. In addition to applying effective strategies and therapies, the two research groups are investigating the responses of the MCI members to treatments that involve acoustical conditions, exercise and movement, and lighting changes that may support retention or relearning of skills. Care partners and family members receive support and instruction to improve home and work life, promoting joy, purpose, and wellness in the family groups. The lighting system uses tunable-white LEDs, employing luminaires with both warm and cool-color emitters that can be dimmed separately to produce any white correlated color temperature (CCT) between 2700 K and 6500 K. All luminaires were dimmable to achieve subdued or lively surroundings for different treatments, time-of-day, and mood. A central networked digital control system was employed to allow tuning of multiple spaces together (for example, bright, cool morning light could be programmed for extra stimulation, or lighting in all spaces at the end of the day could be reduced in both light output and CCT to promote relaxation and not interfere with the melatonin cycle of occupants). Almost all spaces were equipped with individual room control of dimming and color temperature with touch screens to allow users to tune the lighting as desired, but each room’s controls could also be specially programmed through the server in case the research staff were investigating lighting settings on learning, for example. The server incorporates a timeclock, and it is able to send signals to switch off all lighting after occupancy hours, or enable occupancy sensors to control the lighting. The bulk of the construction work was completed in January 2020. It was clear from an initial walk-through that although the lighting system produced the expected high light level with low-glare qualities of light, that there were issues and inconsistencies to be resolved. These were noted in an initial punchlist visit and expected to be resolved when the tech representatives from the agency visited with the electrical contractor in the following few weeks. What followed was 2.5 years of identifying unexpected lighting performance in terms of light output, color, scheduling, and occupancy. This report documents the issues encountered in the effort to get the lighting and controls systems to operate as intended. It concludes with guidance for design professionals and manufacturers to help avoid problematic complexity in future projects.

42 ENGINEERING↗

Common Cause Case Study: An Estimated Probability of Four Solid Rocket Booster Hold-down Post Stud Hang-ups

Until Solid Rocket Motor ignition, the Space Shuttle is mated to the Mobil Launch Platform in part via eight (8) Solid Rocket Booster (SRB) hold-down bolts. The bolts are fractured using redundant pyrotechnics, and are designed to drop through a hold-down post on the Mobile Launch Platform before the Space Shuttle begins movement. The Space Shuttle program has experienced numerous failures where a bolt has "hung-up." That is, it did not clear the hold-down post before liftoff and was caught by the SRBs. This places an additional structural load on the vehicle that was not included in the original certification requirements. The Space Shuttle is currently being certified to withstand the loads induced by up to three (3) of eight (8) SRB hold-down post studs experiencing a "hang-up." The results af loads analyses performed for four (4) stud-hang ups indicate that the internal vehicle loads exceed current structural certification limits at several locations. To determine the risk to the vehicle from four (4) stud hang-ups, the likelihood of the scenario occurring must first be evaluated. Prior to the analysis discussed in this paper, the likelihood of occurrence had been estimated assuming that the stud hang-ups were completely independent events. That is, it was assumed that no common causes or factors existed between the individual stud hang-up events. A review of the data associated with the hang-up events, showed that a common factor (timing skew) was present. This paper summarizes a revised likelihood evaluation performed for the four (4) stud hang-ups case considering that there are common factors associated with the stud hang-ups. The results show that explicitly (i.e. not using standard common cause methodologies such as beta factor or Multiple Greek Letter modeling) taking into account the common factor of timing skew results in an increase in the estimated likelihood of four (4) stud hang-ups of an order of magnitude over the independent failure case.

Cross, Robert↗

SAFETY AT FLUOR HANFORD (B) CASE STUDY - PREPARED BY THE THUNDERBIRD SCHOOL OF GLOBAL MANAGEMENT

One year into the Hanford contract, Fluor had learned a number of hard lessons very quickly. Although the Hanford remediation contract was in many ways a new endeavor for Fluor and a different kind of contract, the organization moved quickly to increase communication with all employees, attack head-on what it considered unsafe and inappropriate safety practices, and strongly inject its own corporate cultural beliefs into the Hanford organization. It wasn't easy, and it didn't happen overnight. From the beginning, Fluor established processes and programs to drive down injury rates. For example, whereas the previous contractor's approach to injuries had been passive, Fluor took a much more aggressive approach to worker injuries. The previous contractor had established a practice of sending injured workers home with the basic directive 'to come back when you are well'. Instead of using outsourced medical assessment, Fluor internalized it and evaluated all claims aggressively. Legitimate claims were quickly settled, and management moved to identify 'repeat offenders' when it came to reportable safety incidents. In the first year of Fluor's management, reportable injuries dropped from 5.37 to 2.99 per 200,000 man-hours. Despite the drop in injury rates, the safety record at Fluor Hanford was not at a level that met either Fluor or the Department of Energy's expectations. Earlier in 1997, Fluor Hanford's proposed safety program was rejected by the DOE. The DOE was not satisfied with Fluor Hanford's proposal for various reasons, including insufficient worker involvement and a lack of accountability. With the need for change clearly established, Fluor Hanford management embarked on a decade-long mission to change the safety culture and improve safety performance. This case describes the key changes and their impact on Fluor Hanford.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Compression of Solar Spectroscopic Observations: a Case Study of MgII k Spectral Line Profiles Observed by NASA’s IRIS Satellite

In this study we extract the deep features and investigate the compression of the MgII k spectral line profiles observed in quiet Sun regions by NASA’s IRIS satellite. The data set of line profiles used for the analysis was obtained on April 20th, 2020, at the center of the solar disc, and contains almost 300,000 individual MgII k line profiles after data cleaning. The data are separated into train and test subsets. The train subset was used to train the autoencoder of the varying embedding layer size. The early stopping criterion was implemented on the test subset to prevent the model from overfitting. Our results indicate that it is possible to compress the spectral line profiles more than 27 times (which corresponds to the reduction of the data dimensionality from 110 to 4) while having a 4DN average reconstruction error, which is comparable to the variations in the line continuum. The mean squared error and the reconstruction error of even statistical moments sharply decrease when the dimensionality of the embedding layer increases from 1 to 4 and almost stop decreasing for higher numbers. The observed occasional improvements in training for values higher than 4 indicate that a better compact embedding may potentially be obtained if other training strategies and longer training times are used. The features learned for the critical four-dimensional case can be interpreted. In particular, three of these four features mainly control the line width, line asymmetry, and line dip formation respectively. The presented results are the first attempt to obtain a compact embedding for spectroscopic line profiles and confirm the value of this approach, in particular for feature extraction, data compression, and denoising.

SMD↗

Benefits of less intrusive remediation alternatives; A review of case studies in Oak Ridge, Tennessee - 15482

Various alternative cleanup strategies have been utilized at Department of Energy facilities in Oak Ridge, Tennessee to avoid costly and potentially ineffective removal of contaminants in soil and sediments, transportation by truck, and long-term storage in landfills. One such example is a remedial decision in the 1990's to not conduct large-scale removal of PCB-contaminated sediments from a large downstream reservoir, and instead implement sediment disturbance controls and monitoring requirements. Monitoring results suggest the decision was a good one with PCB concentrations in fish decreasing substantially over the last 20 years, presumably due to recent cleaner sediments overlying historical sediment layers. At the East Tennessee Technology Park an innovative remediation strategy was developed to reduce human and ecological risks associated with a PCB-contaminated pond, while also enhancing the site's natural resources. Termed the 'Ecological Management and Enhancement' strategy, this remediation option provided an alternative approach to more conventional pond remediation options like sediment and soil removal, draining and capping, and point source/discharge actions. The basic premise of this option is that ecological management, including fish and wildlife management and vegetation management, can interrupt the contaminant exposure pathways that lead to ecological or human receptors. Recent monitoring results have demonstrated both risk reduction and increased natural resource value. Currently under investigation is the use of watershed management approaches that may help ameliorate mercury methylation and bioaccumulation in East Fork Poplar Creek. There is increased recognition that mercury source reduction alone will not achieve the human health risk target level in fish in the downstream environment, where water chemistry and ecological processes are conducive to mercury methylation. Additionally, significant losses in natural resource values are anticipated if major soil and sediment source removal activities are implemented. The Oak Ridge experience suggests that alternative approaches to the conventional 'muck and truck' options to sediment contamination are worth pursuing in some cases. Taking advantage of natural attenuation processes and/or implementing less intrusive water and ecological manipulations could be especially advantageous at contaminated sites where there are multiple or complex sources that are difficult to remediate, conventional source removal is costly, the contaminant of concern is highly bio-accumulative, or where natural resource values could be preserved or enhanced. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Long-range pollution transport during the MILAGRO-2006 campaign: a case study of a major Mexico City outflow event using free-floating altitude-controlled balloons

One of the major objectives of the Megacities Initiative: Local And Global Research 3 Observations (MILAGRO 2006) campaign was to investigate the long-range transport of 4 Mexico City Metropolitan Area (MCMA) pollution outflow and its downwind impacts on air 5 quality and climate. Four aircraft (DOE G-1, NSF/NCAR C-130, NASA-J31, and NASA 6 DC-8) made extensive chemical, aerosol, and radiation measurements above MCMA and over 7 1000 km downwind in order to characterize the evolution of MCMA pollution as it aged and 8 dispersed over the central Mexican plateau and the Gulf of Mexico. As part of this effort, 9 free-floating Controlled-Meteorological (CMET) balloons, capable of changing altitude on 10 command via satellite, characterized the MCMA outflow by performing repeated soundings 11 during the transit. In this paper, we present an analysis based on the data from two CMET 12 balloons that were launched near Mexico City on the afternoon of 18 March 2006 and floated 13 downwind with the outflow for nearly 30 hours. Continuous profile measurements made by 14 the balloons show the evolving structure of the MCMA outflow in considerable detail: its 15 stability and stratification, interaction with other air masses, mixing episodes, and dispersion 16 into the regional background. Air parcel trajectories, computed directly from the balloon 17 wind profiles, show three different transport pathways for Mexico City outflow on 18-19 18 March: (a) high-altitude advection of the top of the MCMA mixed layer, (b) low-altitude flow 19 over the Sierra Madre Oriental followed by decoupling and isolated transport over the Gulf, 20 and (c) the same decoupling scenario with entrainment into a cleaner westerly jet below the 21 plateau. The C-130 intercepted the balloon-based trajectories three times on 19 March, once 22 along each transport pathway. In all three cases, distinct peaks in the urban tracer signature 23 and LIDAR backscatter imagery provided evidence for Mexico City air. The coherence of the 24 high-altitude outflow was well preserved after 25 hours whereas that lower in the atmosphere 25 was more widely dispersed over the same time period. Other C-130 intercepts, previously 26 thought to be from Mexico City, are shown to have likely originated elsewhere. These 27 findings address key questions about the long-range transport of Mexico City pollution and its 28 impact on the regional background. The particular intercepts identified should prove useful in 29 answering a wide range scientific questions pertaining to the transport, transformation, and 30 downwind impacts of megacity air pollution. 31 32

54 ENVIRONMENTAL SCIENCES↗

The Dynamical Role of the Chesapeake Bay on the Local Ozone Pollution Using Mesoscale Modeling—A Case Study

This study investigated the dynamic influence of the Chesapeake Bay (CB) on local ozone (O3) concentration and distribution using a weather forecasting model. The Weather Research and Forecasting model coupled with Chemistry (WRF–Chem) was employed to simulate O3 production and transportation near the CB. Baseline (water) as well as sensitivity (nowater) model experiments of bay circulation were carried out with and without bay water by changing the water surface from water to land (loam). First, the model performance simulating O3 was evaluated using the baseline experiment results and AirNow surface wind and O3 observations. The results showed that the model overestimates surface O3 by up to 20–30%. Further, the comparisons of the baseline and sensitivity experiments revealed higher O3 mixing ratios, primarily due to the resulting bay breeze circulation. These increases, after considering model overestimation, represent a mean bay dynamics circulation-induced contribution of up to 10% at night and 5% during the day. Furthermore, the boundary layer over northern CB, where it is at its narrowest width, was higher (by 1.2 km on average) during daytime due to higher surface temperatures observed. The boundary layer depth difference between the northern, central, and southern regions of the bay leads to a differential in the role of bay circulation dynamics in the observed O3 increase. The relatively wider swath of water surface over southern CB resulted in a lower boundary layer depth and stronger breeze circulation and this circulation contributed to O3 concentrations. Moreover, since the case selected has a minimal bay breeze circulation, the associated surface ozone enhancements represent what is expected at least at a minimum.

Chesapeak Bay↗

Financial Analysis of Incentive Mechanisms to Promote Energy Efficiency: Case Study of a Prototypical Southwest Utility

Many state regulatory commissions and policymakers want utilities to aggressively pursue energy efficiency as a strategy to mitigate demand and energy growth, diversify the resource mix, and provide an alternative to building new, costly generation. However, as the National Action Plan for Energy Efficiency (NAPEE 2007) points out, many utilities continue to shy away from aggressively expanding their energy efficiency efforts when their shareholder's fundamental financial interests are placed at risk by doing so. Thus, there is increased interest in developing effective ratemaking and policy approaches that address utility disincentives to pursue energy efficiency or lack of incentives for more aggressive energy efficiency efforts. New regulatory initiatives to promote increased utility energy efficiency efforts also affect the interests of consumers. Ratepayers and their advocates are concerned with issues of fairness, impacts on rates, and total consumer costs. From the perspective of energy efficiency advocates, the quid pro quo for utility shareholder incentives is the obligation to acquire all, or nearly all, achievable cost-effective energy efficiency. A key issue for state regulators and policymakers is how to maximize the cost-effective energy efficiency savings attained while achieving an equitable sharing of benefits, costs and risks among the various stakeholders. In this study, we modeled a prototypical vertically-integrated electric investor-owned utility in the southwestern US that is considering implementing several energy efficiency portfolios. We analyze the impact of these energy efficiency portfolios on utility shareholders and ratepayers as well as the incremental effect on each party when lost fixed cost recovery and/or utility shareholder incentive mechanisms are implemented. A primary goal of our quantitative modeling is to provide regulators and policymakers with an analytic framework and tools that assess the financial impacts of alternative incentive approaches on utility shareholders and customers if energy efficiency is implemented under various utility operating, cost, and supply conditions.We used and adapted a spreadsheet-based financial model (the Benefits Calculator) which was developed originally as a tool to support the National Action Plan for Energy Efficiency (NAPEE). The major steps in our analysis are displayed graphically in Figure ES- 1. Two main inputs are required: (1) characterization of the utility which includes its initial financial and physical market position, a forecast of the utility?s future sales, peak demand, and resource strategy to meet projected growth; and (2) characterization of the Demand-Side Resource (DSR) portfolio ? projected electricity and demand savings, costs and economic lifetime of a portfolio of energy efficiency (and/or demand response) programs that the utility is planning or considering implementing during the analysis period. The Benefits Calculator also estimates total resource costs and benefits of the DSR portfolio using a forecast of avoided capacity and energy costs. The Benefits Calculator then uses inputs provided in the Utility Characterization to produce a ?business-as usual? base case as well as alternative scenarios that include energy efficiency resources, including the corresponding utility financial budgets required in each case. If a decoupling and/or a shareholder incentive mechanism are instituted, the Benefits Calculator model readjusts the utility?s revenue requirement and retail rates accordingly. Finally, for each scenario, the Benefits Calculator produces several metrics that provides insights on how energy efficiency resources, decoupling and/or a shareholder incentive mechanism impacts utility shareholders (e.g. overall earnings, return on equity), ratepayers (e.g., average customer bills and rates) and society (e.g. net resource benefits).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

NORM in Building Materials: A Case Study in Releasing and Disposing of Building Debris within the DOE System - 18123

In 2013, the Office of Management and Budget issued Memorandum 2013-02, clarifying its 'Freeze the Footprint' policy. Memorandum 2013-02 requires that all federal agencies maintain or reduce their total square footage, within each subsequent year, from a FY2012 baseline. Memorandum 2013-02 also requires that total square footage remain constant with respect to the type/intended use of a building. At Los Alamos National Laboratory (LANL), this means that new construction cannot occur without demolition of equivalent (both in type and square footage) building(s). Since 2013, decommissioning and demolition of aging, unused facilities at LANL has increased. In 2016, the TA16-280 building complex was scheduled for demolition. TA16-280 is a former high explosives (HE) processing facility that consists of six buildings connected to each other via weatherproof walkways. It was constructed in the 1950's and has been subsequently used for HE shipping, receiving, and storage. Interviews with radiation protection staff suggest that some of the buildings within the complex may have been used to store depleted uranium metal parts in a non-dispersible form. It is LANL policy to conduct decommissioning surveys for radioactive materials when building history cannot confirm that a structure is radiologically non-impacted. LANL follows the Multi-Agency Radiation Survey and Assessment of Materials and Equipment (MARSAME) process to develop its surveys and clear structures from radiological control. After clearance, a structure may be dispositioned as non-regulated waste, at a significant cost savings compared to regulated disposition pathways such as low-level waste. MARSAME measurements conducted in the 16-280 complex were elevated compared to reference measurements of surrogate materials, and a majority of the survey units failed to pass indistinguishable from background (IFB), which is LANL's unregulated clearance criteria. Further measurements conducted both in situ and in the laboratory indicated the presence of naturally-occurring thorium in several building materials including: poured concrete, the glaze atop ceramic blast tiles, and the porcelain enamel on the exterior of blast-proof ceiling lamps. Other than naturally-occurring thorium, there were no elevated radionuclide concentrations detected in building materials. It should be noted that there was no history of thorium use in the 16-280 complex, and the material in question was in all cases fixed to and within the building materials in question. Except in certain specific cases, such material is exempt from regulation under the Atomic Energy Act of 1954 [3], as amended, and is therefore exempt from regulation under the Nuclear Regulatory Commission, the Department of Energy, and agreement state regulatory frameworks. Despite this regulatory exemption, disposition of material from the 16-280 complex proved to be challenging, principally because local industrial landfills stipulate 'No radioactive material' in their Waste Acceptance Criteria. This disconnect between what is regulated and what is disposable creates a situation where some DOE sites find it easier to disposition property as Low Level Waste in lieu of pursuing a non-regulated disposition pathway. This presentation will explore the specifics of the 16-280 decommissioning project as well as the implications of the release/disposition disconnect for naturally occurring radioactive material and project planning at LANL. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Is the Chemisorbed CO 2 in Ionic Liquid Electrolytes Active for Electrochemical Utilization? A Case Study on Carboxylate and Carbamate Speciation

This study examines the activity of chemisorbed CO 2 species in the microenvironment formed by bifunctional ionic liquids (ILs) in the reactive capture and conversion (RCC) of CO 2 to CO on silver. Comparative electroanalytical measurements with imidazolium based ILs were performed to probe the impact of electrostatic interactions, anion and cation basicity, and hydrogen bonding on RCC. Particularly, ILs with 1-ethyl-3-methylimidazolium ([EMIM]+) and 1-ethyl-2,3-dimethylimidazolium ([EMMIM]+) cations and aprotic heterocyclic anions of 2-cyanopyrrolide ([2-CNpyr]) and 1,2,4-triazolide ([124-Triz]) were examined for RCC. It was found that anion–CO 2 carbamate complexes facilitate RCC at significantly lower overpotentials compared to cation–CO 2 carboxylate complexes. Additionally, [EMIM]+ was found to better stabilize anion–CO 2 complexes at the interface than [EMMIM]+. Furthermore, it was found that 2-CNpyrH that naturally forms during CO 2 absorption competes for electrode surface adsorption with the anion–CO 2 carbamate complex, thereby reducing the electrochemical activity of the anion–CO 2 complex. These results highlight the importance of IL structure in tuning the interfacial interactions and suggest that ILs with anion-dominated CO 2 chemisorption enhances CO 2 utilization in RCC applications.

Coskun, Oguz Kagan [Case Western Reserve Univ., Cl↗