Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Minibeam radiation therapy for the management of osteosarcomas: A Monte Carlo study

Purpose: Minibeam radiation therapy (MBRT) exploits the well-established tissue-sparing effect provided by the combination of submillimetric field sizes and a spatial fractionation of the dose. The aim of this work is to evaluate the feasibility and potential therapeutic gain of MBRT, in comparison with conventional radiotherapy, for osteosarcoma treatments. Methods: Monte Carlo simulations (PENELOPE/PENEASY code) were used as a method to study the dose distributions resulting from MBRT irradiations of a rat femur and a realistic human femur phantoms. As a figure of merit, peak and valley doses and peak-to-valley dose ratios (PVDR) were assessed. Conversion of absorbed dose to normalized total dose (NTD) was performed in the human case. Several field sizes and irradiation geometries were evaluated. Results: It is feasible to deliver a uniform dose distribution in the target while the healthy tissue benefits from a spatial fractionation of the dose. Very high PVDR values (⩾20) were achieved in the entrance beam path in the rat case. PVDR values ranged from 2 to 9 in the human phantom. NTD{sub 2.0} of 87 Gy might be reached in the tumor in the human femur while the healthy tissues might receive valley NTD{sub 2.0} lower than 20 Gy. The doses in the tumor and healthy tissues might be significantly higher and lower than the ones commonly delivered used in conventional radiotherapy. Conclusions: The obtained dose distributions indicate that a gain in normal tissue sparing might be expected. This would allow the use of higher (and potentially curative) doses in the tumor. Biological experiments are warranted.

61 RADIATION PROTECTION AND DOSIMETRY↗

NNL.Fe.qSNAP-ZBL.2024.1: A Fe Spectral Neighbor Analysis Potential for Radiation Damage Simulations

The NNL.Fe.qSNAP-ZBL.2024.1 machine-learned potential (MLP) has been generated to support the development of an elemental body-centered cubic (BCC) Fe athermal recombination corrected neutron damage model and simulations of primary recoil atom (PRA) cascades in BCC Fe. This MLP is a quadratic spectral neighbor analysis potential (qSNAP) hybridized with the universal Ziegler-Beirsack-Littmark (ZBL) potential at short-range and is named according to Naval Nuclear Laboratory MLP naming conventions (NNL.material-system.MLP-type.year.version). Training set calculations for Fe are presented along with the subsequent MLP fitting procedure. A key criterion of the fitting procedure is that ZBL describes the short-range interaction with minimal impact on the MLP. The MLP is compared to density functional theory (DFT) predicted properties relevant to radiation damage simulation, including threshold displacement energies, for validation. The NNL.Fe.qSNAP-ZBL.2024.1 potential is considered suitable for molecular dynamics (MD) simulations of radiation defects up to 800 K and PRA cascades in BCC Fe up to around 10 keV. The potential can additionally be used on a limited basis for recoils of 10–20 keV, within which range the emergence of structures outside the training set in cascade simulations may cause system instabilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The majorana experiment

The MAJORANA Collaboration is assembling an array of HPGe detectors to search for neutrinoless double-beta decay in {sup 76}Ge. Initially, MAJORANA aims to construct a prototype module to demonstrate the potential of a future 1-tonne experiment. The design and potential reach of this prototype DEMONSTRATOR module are presented. Our proposed method uses the well-established technique of searching for neutrinoless double-beta decay in high purity Ge-diode radiation detectors that play both roles of source and detector. The use of P-PC Ge detectors present advances in background rejection and a Significantly lower energy threshold than conventional Ge detector technologies. The lower energy threshold opens up a broader and exciting physics program including searches for dark matter and axions concurrent with the double-beta decay search. The DEMONSTRATOR should establish that the backgrounds are low enough to justify scaling to tonne-scale experiment, probe the neutrino effective mass region above 100 meV, and search the low energy region with a sensitivity to dark matter. The DEMONSTRATOR will be sited at the 4850-ft level (4200 m.w.e) of the Sanford Underground Laboratory at Homestake and preparations for construction are currently underway.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance analysis of a latent heat storage system with phase change material for new designed solar collectors in greenhouse heating

The continuous increase in the level of greenhouse gas emissions and the rise in fuel prices are the main driving forces behind the efforts for more effectively utilize various sources of renewable energy. In many parts of the world, direct solar radiation is considered to be one of the most prospective sources of energy. In this study, the thermal performance of a phase change thermal storage unit is analyzed and discussed. The storage unit is a component of ten pieced solar air collectors heating system being developed for space heating of a greenhouse and charging of PCM. CaCl{sub 2}6H{sub 2}O was used as PCM in thermal energy storage with a melting temperature of 29 C. Hot air delivered by ten pieced solar air collector is passed through the PCM to charge the storage unit. The stored heat is utilized to heat ambient air before being admitted to a greenhouse. This study is based on experimental results of the PCM employed to analyze the transient thermal behavior of the storage unit during the charge and discharge periods. The proposed size of collectors integrated PCM provided about 18-23% of total daily thermal energy requirements of the greenhouse for 3-4 h, in comparison with the conventional heating device. (author)

14 SOLAR ENERGY↗

Means of Intensity Modulation of Radiation in External Radiotherapy

The paper deals with the main means of the beam intensity modifications that are used in radio therapeutic praxis. Physical principles and the main characteristics of the physical wedges and the enhanced dynamic wedges (EDW) are described. The main advantages and the disadvantages of the EDW over the conventional physical wedges are listed. The paper describes also a process of dosimetry verification of the application of the EDW that was applied on The Saint Elizabeth Cancer Institute in Bratislava and it details the experiment of the verification of an isodose distribution within this implementation of the EDW.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Current State of Radiation Dosimetry in Radionuclide Therapy

Radionuclide therapy combines the specificity of cancer cell targeting with the well-known cytotoxic effects of ionizing radiation. It has the potential to simultaneously eradicate both the primary tumor site as well as the metastatic extent of the disease throughout the body. Despite these advantages, a major limitation of radionuclide therapy is that conventional internal dosimetry methods have failed to accurately predict treatment outcomes in patients. It has been proposed that this shortcoming is due to the fact that therapeutic dosimetry is typically performed using methods developed for diagnostic imaging that do not consider patient specific anatomy, pharmacokinetics and dose heterogeneity. Even worse, dosimetry methods are often completely neglected during treatment planning and dose prescription is based on Body Surface Area/Weight (BSA/BW) and platelet counts. The most widely used internal dosimetry software is OLINDA/EXM (Organ Level Internal Dose Assessment for Exponential Modeling). OLINDA/EXM calculates absorbed doses using the formulism developed by the Medical Internal Radiation Dose (MIRD) committee of the Society of Nuclear Medicine. In its current implementation, OLINDA/EXM requires the use of S factors, which are derived in phantoms that do not accurately represent the actual patient. In addition, OLINDA/EXM assumes that the activity distribution in each organ and tumor is uniform, when it has been well established that activity distributions are often highly heterogeneous. Furthermore, the tumor is not modeled in the phantom, which introduces additional uncertainties in the calculation. Due to these limitations, there is a clear need for improved dosimetry methods for therapeutic nuclear medicine that utilize patient-specific imaging information. A variety of efforts are currently underway to develop such methods. There are two commercial software packages on the market for voxel level internal dosimetry: STRATOS (Philips Technologies, Aachen, Germany) and VoxelDose (DosiSoft, Cachan, France), but both packages are not widely used in clinical practice. In addition, several academic platforms have been developed. Similar to these offerings, RAPID is a robust, fast and multimodal platform. However, RAPID has been designed with tremendous flexibility to perform accurate dosimetry for any radiopharmaceutical in the pre-clinical and clinical setting in order to aid in drug development and to assist in radionuclide therapy treatment planning. This presentation will overview existing dosimetry platforms while focusing on the Monte Carlo-based platform developed at the University of Wisconsin known as RAPID (Radiopharmaceutical Assessment Platform for Internal Dosimetry). RAPID is a robust and universal platform that can provide accurate 3D internal dosimetry for any radiopharmaceutical during both the pre-clinical and clinical stages of drug development as well as clinical treatment planning in TRT. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Pulse Length Control in an X-Ray FEL by Using Wakefields

For the users of the high-brightness radiation sources of free-electron lasers it is desirable to reduce the FEL pulse length to 10 fs and below for time-resolved pump and probe experiments. Although it can be achieved by conventional compression methods for the electron beam or the chirped FEL pulse, the technical realization is demanding. In this presentation we study the impact of longitudinal wakefields in the undulator and how their properties can be used to reduced the amplifying part of the bunch to the desired length. Methods of actively controlling the wakefields are presented.

43 PARTICLE ACCELERATORS↗

Hyperfine interactions in {sup 61}Ni with synchrotron-radiation-based perturbed angular correlations

We report on the observation of perturbed angular {gamma}-{gamma} correlations with 67.41 keV nuclear resonance of {sup 61}Ni using nuclear resonance scattering of synchrotron radiation. The dependence of the correlations on the direction and the magnitude of the hyperfine magnetic field is demonstrated in the feasibility study with nickel metal. The interpretation of the experimental data is done using modification of the theory of conventional perturbed angular correlations for the case of the linearly polarized first photon.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synchrotron FTIR Imaging For The Identification Of Cell Types Within Human Tissues

The use of synchrotron Fourier Transform Infrared spectroscopy (S-FTIR) has been shown to be a very promising tool for biomedical research. S-FTIR spectroscopy allows for the fast acquisition of infrared (IR) spectra at a spatial resolution approaching the IR diffraction limit. The development of the Infrared Environmental Imaging (IRENI) beamline at the Synchrotron Radiation Center (SRC) at the University of Wisconsin-Madison has allowed for diffraction limited imaging measurements of cells in human prostate and breast tissues. This has allowed for the identification of cell types within tissues that would otherwise not have been resolvable using conventional FTIR sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron radiation shielding material polyethylene: consequences of gamma irradiation - 15062

High and ultra-high molecular weight polyethylenes are high performance materials, which are predestined for a wide range of applications due to characteristics like high density, low weight, good dimensional stability, high chemical resistance, and high hydrogen content. These polymers are used in two demanding areas: as implant material in medical technology (only ultra-high molecular weight polyethylenes) and as a component for neutron shielding purposes in casks for storage and transport of radioactive waste. In the medical field (joint replacements) as well as during neutron radiation shielding application, high and ultra-high molecular weight polyethylenes are exposed to gamma irradiation: in the first case requested as sterilization process and for surface-crosslinking and in the second case existing as a side effect of inserting the radioactive material in the cask. Given that polyethylene as shielding material has to withstand any type of degradation affecting safety relevant aspects to be applicable for long-term radiation shielding purposes for instance over a period of 40 years, the durability of the material is of special interest. High molecular weight polyethylene (HMW-PE; LUPOLEN 5261Z; Lyondell Basell) and ultra-high molecular weight polyethylene (UHMW-PE; GUR 4120; Ticona) were subjected to gamma radiation and afterwards thermally treated. The gamma doses used are in the range of 50 to 600 kGy and irradiation takes place at RT using a Co-60 source. The planned thermal treatment will take place at a temperature of 125 deg.C for periods of minimum 30 days and maximum of five years. With the applied conventional analytical techniques it is possible to detect structural changes of both types of polyethylene induced by gamma irradiation and certainly of thermal treatment. Through gamma irradiation melting temperature, crystallinity, and density, respectively increased. Furthermore both polyethylenes get oxidized and cross-linked. With regard to the special application as neutron radiation shielding material in casks for storage and transport of radioactive materials, the impact of irradiation lead to changes of material properties. A consolidated view indicates that the detected changes of the irradiated (U)HMW-PE are not safety relevant for long-term neutron radiation shielding purposes over a period of 40 years in Germany. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On the feasibility of polyurethane based 3D dosimeters with optical CT for dosimetric verification of low energy photon brachytherapy seeds

Purpose: To investigate the feasibility of and challenges yet to be addressed to measure dose from low energy (effective energy <50 keV) brachytherapy sources (Pd-103, Cs-131, and I-125) using polyurethane based 3D dosimeters with optical CT. Methods: The authors' evaluation used the following sources: models 200 (Pd-103), CS-1 Rev2 (Cs-131), and 6711 (I-125). The authors used the Monte Carlo radiation transport code MCNP5, simulations with the ScanSim optical tomography simulation software, and experimental measurements with PRESAGE{sup ®} dosimeters/optical CT to investigate the following: (1) the water equivalency of conventional (density = 1.065 g/cm{sup 3}) and deformable (density = 1.02 g/cm{sup 3}) formulations of polyurethane dosimeters, (2) the scatter conditions necessary to achieve accurate dosimetry for low energy photon seeds, (3) the change in photon energy spectrum within the dosimeter as a function of distance from the source in order to determine potential energy sensitivity effects, (4) the optimal delivered dose to balance optical transmission (per projection) with signal to noise ratio in the reconstructed dose distribution, and (5) the magnitude and characteristics of artifacts due to the presence of a channel in the dosimeter. Monte Carlo simulations were performed using both conventional and deformable dosimeter formulations. For verification, 2.8 Gy at 1 cm was delivered in 92 h using an I-125 source to a PRESAGE{sup ®} dosimeter with conventional formulation and a central channel with 0.0425 cm radius for source placement. The dose distribution was reconstructed with 0.02 and 0.04 cm{sup 3} voxel size using the Duke midsized optical CT scanner (DMOS). Results: While the conventional formulation overattenuates dose from all three sources compared to water, the current deformable formulation has nearly water equivalent attenuation properties for Cs-131 and I-125, while underattenuating for Pd-103. The energy spectrum of each source is relatively stable within the first 5 cm especially for I-125. The inherent assumption of radial symmetry in the TG43 geometry leads to a linear increase in sample points within the 3D dosimeter as a function of distance away from the source, which partially offsets the decreasing signal. Simulations of dose reconstruction using optical CT showed the feasibility of reconstructing dose out to a radius of 10 cm without saturating projection images using an optimal dose and high dynamic range scanning; the simulations also predicted that reconstruction artifacts at the channel surface due to a small discrepancy in refractive index should be negligible. Agreement of the measured with calculated radial dose function for I-125 was within 5% between 0.3 and 2.5 cm from the source, and the median difference of measured from calculated anisotropy function was within 5% between 0.3 and 2.0 cm from the source. Conclusions: 3D dosimetry using polyurethane dosimeters with optical CT looks to be a promising application to verify dosimetric distributions surrounding low energy brachytherapy sources.

07 ISOTOPE AND RADIATION SOURCES↗

A three-parameter approximation for radiative transfer in nonhomogeneous atmospheres - Application to the O3 9.6-micron band

A three-parameter scaling approximation is developed in conjunction with random models for the computation of transmittance along nonhomogeneous atmospheres. In addition to the scaled path length and pressure, a third parameter is introduced to account for intermediate absorption. With reference to the results derived from line-by-line calculations, the accuracy of this scaling approximation is assessed in different atmospheric conditions. For the O3 9.6-micron band where the Curtis-Godson and other conventional scaling methods usually produce large errors, the present model can achieve relative accuracies within about 1 percent in transmittance and the downward surface flux. Accuracy of about 0.15 K/d can be obtained in cooling rate calculations. The present three-parameter approximation is well suited for radiative transfer parameterizations in which the demand for high accuracy is required in the transmittance and flux calculations.

Fu, Qiang↗

Characterization of Electronic Materials HgZnSe and HgZnTe Using Innovative and Conventional Techniques

HgZnSe and HgZnTe are electronic materials of interest for potential IR detector and focal plane array applications due to their improved strength and compositional stability over HgCdTe, but they are difficult to grow on Earth and to fully characterize. Conventional contact methods of characterization, such as Hall and van der Paw, although adequate for many situations are typically labor intensive and not entirely suitable where only very small samples are available. To adequately characterize and compare properties of electronic materials grown in low earth orbit with those grown on Earth, innovative techniques are needed that complement existing methods. This paper describes the implementation and test results of a unique non-contact method of characterizing uniformity, mobility, and carrier concentration together with results from conventional methods applied to HgZnSe and HgZnTe. The innovative method has advantages over conventional contact methods since it circumvents problems of possible contamination from alloying electrical contacts to a sample and also has the capability to map a sample. Non- destructive mapping, the determination of the carrier concentration and mobility at each place on a sample, provides a means to quantitatively compare, at high spatial resolution, effects of microgravity on electronic properties and uniformity of electronic materials grown in low-Earth orbit with Earth grown materials. The mapping technique described here uses a 1mm diameter polarized beam of radiation to probe the sample. Activation of a magnetic field, in which the sample is placed, causes the plane of polarization of the probe beam to rotate. This Faraday rotation is a function of the free carrier concentration and the band parameters of the material. Maps of carrier concentration, mobility, and transmission generated from measurements of the Faraday rotation angles over the temperature range from 300K to 77K will be presented. New information on band parameters, obtained by combining results from conventional Hall measurements of the free carrier concentration with Faraday rotation measurements, will also be presented. One example of how this type of information was derived is illustrated in the following figure which shows Faraday rotation vs wavelength modeled for Hg(l-x)ZnxSe at a temperature of 300K and x=0.07. The plasma contribution, total Faraday rotation, and interband contribution to the Faraday rotation, are designated in the Figure as del(p), FR tot, and del(i) respectively. Experimentally measured values of FR tot, each indicated by + , agree acceptably well with the model at the probe wavelength of 10.6 microns. The model shows that at the probe wavelength, practically all the rotation is due to the plasma component, which can be expressed as delta(sub p)= 2pi(e(sup 3))NBL/c(sup 2)nm*(sup 2) omega(sup 2). In this equation, delta(sub p) is the rotation angle due to the free carrier plasma, N is the free carrier concentration, B the magnetic field strength, L the thickness of the sample, n the index of refraction, omega the probe radiation frequency, c the speed of light, e the electron charge, and m* the effective mass. A measurement of N by conventional techniques, combined with a measurement of the Faraday rotation angle allows m* to be accurately determined since it is an inverse square function.

Tanton, George↗

Poster — Thur Eve — 28: Enabling trajectory-based radiotherapy on a TrueBeam accelerator with the Eclipse treatment planning system

The TrueBeam linear accelerator platform has a developer's mode which permits the user dynamic control over many of the machine's mechanical and radiation systems. Using this research tool, synchronous couch and gantry motion can be programmed to simulate isocentric treatment with a shortened SAD, with benefits such as smaller projected MLC leaf widths and an increased dose rate. In this work, water tank measurements were used to commission a virtual linear accelerator with an 85 cm SAD in Eclipse, from which several arc-based radiotherapy treatments were generated, including an inverse optimized VMAT delivery. For each plan, the pertinent treatment delivery information was extracted from control points specified in the Eclipse-exported DICOM files using the pydicom package in Python, allowing construction of an XML control file. The dimensions of the jaws and MLC positions, defined for an 85 cm SAD in Eclipse, were scaled for delivery on a conventional SAD linear accelerator, and translational couch motion was added as a function of gantry angle to simulate delivery at 85 cm SAD. Ionization chamber and Gafchromic film measurements were used to compare the radiation delivery to dose calculations in Eclipse. With the exception of the VMAT delivery, ionization chamber measurements agreed within 3.3% of the Eclipse calculations. For the VMAT delivery, the ionization chamber was located in an inhomogeneous region, but gamma evaluation of the Gafchromic film plane resulted in a 94.5% passing rate using criteria of 3 mm/3%. The results indicate that Eclipse calculation infrastructure can be used.

07 ISOTOPE AND RADIATION SOURCES↗

Measurement of neutron dose equivalent outside and inside of the treatment vault of GRID therapy

Purpose: To evaluate the neutron and photon dose equivalent rates at the treatment vault entrance (H{sub n,D} and H{sub G}), and to study the secondary radiation to the patient in GRID therapy. The radiation activation on the grid was studied.Methods: A Varian Clinac 23EX accelerator was working at 18 MV mode with a grid manufactured by .decimal, Inc. The H{sub n,D} and H{sub G} were measured using an Andersson–Braun neutron REM meter, and a Geiger Müller counter. The radiation activation on the grid was measured after the irradiation with an ion chamber γ-ray survey meter. The secondary radiation dose equivalent to patient was evaluated by etched track detectors and OSL detectors on a RANDO{sup ®} phantom.Results: Within the measurement uncertainty, there is no significant difference between the H{sub n,D} and H{sub G} with and without a grid. However, the neutron dose equivalent to the patient with the grid is, on average, 35.3% lower than that without the grid when using the same field size and the same amount of monitor unit. The photon dose equivalent to the patient with the grid is, on average, 44.9% lower. The measured average half-life of the radiation activation in the grid is 12.0 (±0.9) min. The activation can be categorized into a fast decay component and a slow decay component with half-lives of 3.4 (±1.6) min and 15.3 (±4.0) min, respectively. There was no detectable radioactive contamination found on the surface of the grid through a wipe test.Conclusions: This work indicates that there is no significant change of the H{sub n,D} and H{sub G} in GRID therapy, compared with a conventional external beam therapy. However, the neutron and scattered photon dose equivalent to the patient decrease dramatically with the grid and can be clinical irrelevant. Meanwhile, the users of a grid should be aware of the possible high dose to the radiation worker from the radiation activation on the surface of the grid. A delay in handling the grid after the beam delivery is suggested.

61 RADIATION PROTECTION AND DOSIMETRY↗

Polyurea-Based Aerogel Monoliths and Composites

aerogel insulation material was developed that will provide superior thermal insulation and inherent radiation protection for government and commercial applications. The rubbery polyureabased aerogel exhibits little dustiness, good flexibility and toughness, and durability typical of the parent polyurea polymer, yet with the low density and superior insulation properties associated with aerogels. The thermal conductivity values of polyurea-based aerogels at lower temperature under vacuum pressures are very low and better than that of silica aerogels. Flexible, rubbery polyurea-based aerogels are able to overcome the weak and brittle nature of conventional inorganic and organic aerogels, including polyisocyanurate aerogels, which are generally prepared with the one similar component to polyurethane rubber aerogels. Additionally, with higher content of hydrogen in their structures, the polyurea rubber-based aerogels will also provide inherently better radiation protection than those of inorganic and carbon aerogels. The aerogel materials also demonstrate good hydrophobicity due to their hydrocarbon molecular structure. There are several strategies to overcoming the drawbacks associated with the weakness and brittleness of silica aerogels. Development of the flexible fiber-reinforced silica aerogel composite blanket has proven to be one promising approach, providing a conveniently fielded form factor that is relatively robust in industrial environments compared to silica aerogel monoliths. However, the flexible, silica aerogel composites still have a brittle, dusty character that may be undesirable, or even intolerable, in certain application environments. Although the cross - linked organic aerogels, such as resorcinol- formaldehyde (RF), polyisocyanurate, and cellulose aerogels, show very high impact strength, they are also very brittle with little elongation (i.e., less rubbery). Also, silica and carbon aerogels are less efficient radiation shielding materials due to their lower content of hydrogen element. The invention involves mixing at least one isocyanate resin in solvent along with a specific amount of at least one polyamine hardener. The hardener is selected from a group of polyoxyalkyleneamines, amine-based polyols, or a mixture thereof. Mixing is performed in the presence of a catalyst and reinforcing inorganic and/or organic materials, and the system is then subjected to gelation, aging, and supercritical drying. The aerogels will offer exceptional flexibility, excellent thermal and physical properties, and good hydrophobicity. The rubbery polyurea-based aerogels are very flexible with no dust and hydrophobic organics that demonstrated the following ranges of typical properties: densities of 0.08 to 0.293 g/cu cm, shrinkage factor (raerogel/rtarget) = 1.6 to 2.84, and thermal conductivity values of 15.2 to 20.3 mW/m K.

Lee, Je Kyun↗

Exclusive Alternating Chemotherapy and Radiotherapy in Nonmetastatic Inflammatory Breast Cancer: 20 Years of Follow-Up

Background: Locoregional treatment of inflammatory breast cancer (IBC) is crucial because local relapses may be highly symptomatic and are commonly associated with distant metastasis. With a median follow-up of 20 years, we report here the long-term results of a monocentric clinical trial combining primary chemotherapy (CT) with a schedule of anthracycline-based CT and an alternating split-course of radiotherapy (RT Asterisk-Operator CT) without mastectomy. Methods and Materials: From September 1983 to December 1989, 124 women with nonmetastatic IBC (T4d M0) were treated with three cycles of primary AVCMF chemotherapy (anthracycline, vincristine, cyclophosphamide, methotrexate, and 5-fluorouracil) and then an alternating RT Asterisk-Operator CT schedule followed by three cycles of FAC. Hormonal therapy was systematically administered: ovarian irradiation (12 Gy in four fractions) or tamoxifen 20 mg daily. Results: Local control was achieved in 82% of patients. The 10- and 20-year local relapse rates were 26% and 33%, respectively, but only 10% of locally controlled cases were not associated with concurrent distant metastasis. The 10- and 20-year overall survival rates were 39% and 19%, respectively. Severe fibrosis occurred in 54% of patients, grade 3 brachial plexus neuropathy in 4%, grade 2 pneumonitis in 9%. Grade 1, 2 and 3 cardiac toxicity was observed in 3.8%, 3.8% and 1.2% of cases respectively. Conclusions: This combined regimen allowed good long-term local control without surgery. Survival rates were similar to those obtained with conventional regimens (primary chemotherapy, total mastectomy, and adjuvant radiotherapy). Since IBC continues to be an entity with a dismal prognosis, this approach, safely combining preoperative or postoperative radiation therapy and systemic treatments, should be reassessed when suitable targeted agents are available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Characterization of Scintillator Performance at Temperatures up to 400 Degrees Centigrade

The logging and characterization of geothermal wells requires improved scintillator systems that are capable of operation at temperatures significantly above those commonly encountered in the logging of most conventional oil and gas wells (e.g., temperatures nominally in the range of up to 150oC.) Unfortunately, most of the existing data on the performance of scintillators for radiation detection at elevated temperatures is fragmentary, uncorrelated, and generally limited to relatively low temperatures in most cases to temperatures well below 200oC. We have designed a system for characterizing scintillator performance at temperatures extending up to 400oC under inert atmospheric conditions, and this system is applied here to the determination of scintillator performance at elevated temperatures for a wide range of scintillators including, among others: bismuth germanate, cadmium tungstate, cesium iodide, cesium iodide (Tl), cesium iodide (Na), sodium iodide, sodium iodide (Tl), lutetium oxy-orthosilicate (Ce), zinc tungstate, yttrium aluminum perovskite (Ce), yttrium aluminum garnet (Ce), lutetium aluminum perovskite (Ce), and barium fluoride, strontium iodide(Eu). The results of these high-temperature scintillator performance tests are described in detail here. Comparisons of the relative elevated-temperature properties of the various scintillator materials have resulted in the identification of promising scintillator candidates for high-temperature use in geothermal and fossil-fuel well environments.

gamma ray↗