Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibrating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

FAST Model Calibration and Validation of the OC5-DeepCwind Floating Offshore Wind System Against Wave Tank Test Data

During the course of the Offshore Code Comparison Collaboration, Continued, with Correlation (OC5) project, which focused on the validation of numerical methods through comparison against tank test data, the authors created a numerical FAST model of the 1:50-scale DeepCwind semisubmersible system that was tested at the Maritime Research Institute Netherlands ocean basin in 2013. This paper discusses several model calibration studies that were conducted to identify model adjustments that improve the agreement between the numerical simulations and the experimental test data. These calibration studies cover wind-field-specific parameters (coherence, turbulence), hydrodynamic and aerodynamic modeling approaches, as well as rotor model (blade-pitch and blade-mass imbalances) and tower model (structural tower damping coefficient) adjustments. These calibration studies were conducted based on relatively simple calibration load cases (wave only/wind only). The agreement between the final FAST model and experimental measurements is then assessed based on more-complex combined wind and wave validation cases.

17 WIND ENERGY↗

Reduced chemistry model calibration using unsteady flames with repetitive extinction and ignition

In this paper, combustion in a narrow channel with an imposed temperature gradient is used to calibrate a reduced chemical mechanism. The focus is placed on unsteady flames with repetitive extinction and ignition (FREI) at high pressure. The reduced mechanism follows a hybrid approach, combining a small fuel-dependent submechanism with a detailed fuel-independent submechanism for the core species chemistry. The fuel-dependent submechanism consists of three species and nine reactions describing both the low and high-temperature fuel decomposition pathways. The sensitivity of the extinction and ignition locations to the fuel-dependent reactions is assessed and multiple reactions are found to affect the FREI behavior. The sensitive reactions are calibrated following a Bayesian approach. The calibrated reduced model is compared to a detailed model and good agreement in ignition delay times and laminar flame speeds is observed. Finally, this illustrates the potential of a micro flow reactor with a controlled temperature profile to test fuels, calibrate chemical models, and infer kinetic data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutronics Analysis of TREAT Multi-SERTTA Calibration Test Vehicle (Multi-SERTTA CAL)

Transient testing is a necessary step in the performance evaluation of Accident Tolerant Fuels (ATF) developed as part of the Fuel Cycle Research and Development Advanced Fuels Campaign initiated and supported by the United States Department of Energy (DOE-NE). These advanced fuels are expected to be used in future reactors or replace the current fuel design used in existing power reactors for enhanced performance and safety. Upon completion of a process proscribed by the National Environmental Policy Act, the Transient Reactor Test (TREAT) facility, located at Idaho National Laboratory (INL), was chosen by DOE-NE to provide the desired specialized testing. TREAT has successfully operated from start-up in 1959 to 1994 when it was placed on operational stand-by. Careful preparations are being made for operational readiness and TREAT is projected to resume testing no later than 2018. Past TREAT testing primarily focused on sodium-cooled reactor fuels (SRF). Test vehicle designs varied to accommodate testing needs ranging from separate effects tests to integral tests approaching simulation of actual reactor environment conditions including forced convection cooling. The current focus on light water reactor (LWR) ATF requires design of new experiment vehicles to accommodate the water/steam environment and associated complexities regarding desired energy deposition into the specimen and proper containment. The first set of experiments in TREAT restart is expected to be conducted with the Multi-SERTTA (Static Environment Rodlet Transient Test Apparatuses). Difficult to quantify and calculate integral and time dependent effects inherent in transient testing limit predictive modeling capability; therefore, calibration testing in TREAT prior to the actual experiment is necessary to empirically determine the effectiveness of core-to-specimen power coupling in order to achieve the desired energy deposition into the test specimen during a nuclear power transient. This has been done in the past, in part, by evaluating the difference in energy deposition into dosimeter wires subjected to various TREAT time dependent power conditions. These calibration tests were typically conducted in a test vehicle neutronically similar to the actual test vehicle, but more simplistic in design in order to quickly retrieve and analyze dosimeter wires and minimize containment structure costs due to several trials. Prior calibration testing for SRF experiments could be conducted without coolant as sodium has no notable neutronic effect on the core-to-specimen power coupling factor (PCF). Such is not the case with LWR fuel where water serves as both moderator and coolant. This presents a design challenge as the calibration test vehicle must retain heated, high-pressure water to preserve neutronic equivalence representative of near prototypic reactor conditions while allowing for quick retrieval of dosimeters. The solution to this challenge comes in the form of a thin walled dry well positioned through the center of the basic Multi-SERTTA design. Test vehicle reactivity worth and PCF are two important factors with respect to ascertainment of neutronic equivalence. Similarity in test vehicle reactivity worth is desired to avoid the need to change operational core rod positions in TREAT which could significantly alter neutron flux distribution and consequently power distribution throughout the core and into the test specimen. The geometry and composition of various materials within the experiment containment structure can also significantly alter the quality of neutron signal delivery from the core to the test specimen. Introduction of an Inconel tube, albeit very thin, is expected to impact PCF. Simple modifications to the CAL design may compensate for the anticipated change. Evaluation of these factors and proposed modifications through neutronics analysis serves to inform experiment design and is a valuable tool towards achieving the optimal CAL design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Calibration of COBRA-TF and STAR-CCM+ with Dakota 6.5 for CASL

High-to-low (Hi2Lo) is utilizing a validated model in a high resolution code to generate synthetic data for improvement of the same model in a lower resolution code. This process is useful in cases where experimental data does not exist or is not sufficient. Data from the high resolution code is treated as calibration data (with appropriate uncertainties and error bounds) which can be used to train parameters that affect solution accuracy in the lower resolution code model and reduce uncertainty. Implementing the Hi2Lo process between COBRA-TF (CTF) and STAR-CCM+ (STAR) within a Dakota 6.5 framework is the goal of this work. High resolution results provided by STAR will eventually be used in addition to experimental data from Westinghouse Electric Company (WEC) to reduce uncertainty in the CTF model. The scope of the work presented herein is a proof of concept for deterministic calibration using Dakota and is not a demonstration of the Hi2Lo process. CTF temperatures will be calibrated to WEC experimental data as a first demonstration of the calibration process. Validation of the CTF model with experimental data was performed previously.

42 ENGINEERING↗

VALIDATION, VERIFICATION, AND CALIBRATION THROUGH A CAUSAL LENS

This paper presents an alternative method based on causal inference to perform validation, verification, and calibration of simulation models. While classical validation and verification approaches focus on the identification of the associations between data elements using statistical and machine learning methods, the novel methods in this paper focus instead on the identification of causal relationships between data elements. Statistical and machine learning-based approaches are strictly data-driven, meaning that they provide quantitative comparison measures between datasets without explicitly considering the hypotheses behind them. This can lead to the erroneous conclusion that, if two data sets are close enough, then the models that generated them are similar. In addition, when experimental and simulated data differ to an extent that fails to meet the acceptance criteria, calibration techniques are used to tweak simulation model parameters to reduce the gap between the two types of data. This produces the false expectation that a simulation model will match reality. The methods presented in this paper move away from these strictly data-driven methods for validation and calibration toward more robust, model-driven methods based on causal inference. Causal inference aims to identify the possible mechanisms that might have generated data. Thus, this analysis targets the prediction of the effects when one (or more) of the identified mechanisms are altered. There are many approaches to identify, quantify and illustrate causal relationships. For the scope of this paper, directed graphs are employed as causal models. If the directed graph lacks cycles it is known as a directed acyclic graph (DAG). A node in such a graph represents an observed data element while a directed edge connecting two nodes represents a causal relationship between two variables. The developed causal methods are designed to extract causal models from simulation models and from experimental data. Causal models capture the causal relationships between data elements (e.g., simulated and experimental data). In this context, validation and verification are performed by comparing causal models. The proposed approach does not only inform system analysts on how a simulation model matches real-world data, but also identifies elements of the simulation model that should be revised when discrepancies between simulation and experimental data are observed. Through these causal methods, analysts have a means to identify the portion of the model equation(s) that are behind an edge connecting two variables. Hence, once the structural differences between causal models have been determined, model calibration can occur by changing only those model parameters that impact the identified causal relationships.

97 MATHEMATICS AND COMPUTING↗

Enhancing Seismic Calibration Research Through Software Automation and Scientific Information Management

The National Nuclear Security Administration (NNSA) Ground-Based Nuclear Explosion Monitoring Research and Development (GNEMRD) Program at LLNL continues to make significant progress enhancing the process of deriving seismic calibrations and performing scientific integration, analysis, and information management with software automation tools. Our tool efforts address the problematic issues of very large datasets and varied formats encountered during seismic calibration research. New information management and analysis tools have resulted in demonstrated gains in efficiency of producing scientific data products and improved accuracy of derived seismic calibrations. In contrast to previous years, software development work this past year has emphasized development of automation at the data ingestion level. This change reflects a gradually-changing emphasis in our program from processing a few large data sets that result in a single integrated delivery, to processing many different data sets from a variety of sources. The increase in the number of sources had resulted in a large increase in the amount of metadata relative to the final volume of research products. Software developed this year addresses the problems of: (1) Efficient metadata ingestion and conflict resolution; (2) Automated ingestion of bulletin information; (3) Automated ingestion of waveform information from global data centers; and (4) Site Metadata and Response transformation required for certain products. This year, we also made a significant step forward in meeting a long-standing goal of developing and using a waveform correlation framework. Our objective for such a framework is to extract additional calibration data (e.g. mining blasts) and to study the extent to which correlated seismicity can be found in global and regional scale environments.

58 GEOSCIENCES↗

Calibration of the modulation transfer function of surface profilometers with binary pseudo-random test standards: Expanding the application range

A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010]. Here we report on a significant expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

47 OTHER INSTRUMENTATION↗

Calibration and optimization of proportional counter modules using Garfield

Prototypes of radiation detector arrays used for charged-particle radiography require iniliol calibration to correlate the distribution of electron arrival time to the particle track locations. This step is crucial to obtaining the spatial resolution necessary to separate particle tracks traversing the individual proportional counters in the arrays. Our past attempts to use cosmic rays alone for the initial calibration have fallen short of obtaining the desired resolution due to the insufficient cosmic ray flux to provide the necessary number of particle tracks. A theoretical relation between electron drift time and radial drift distance is obtained with Garfield, a CERN gas detector simulation program. This relation is then used as an effective starting point for the initial calibration and results in a shorter calibration period and improved spatial resolution of the detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiometer Calibration and Characterization (RCC) User's Manual: Windows Version 4.0

The Radiometer Calibration and Characterization (RCC) software is a data acquisition and data archival system for performing Broadband Outdoor Radiometer Calibrations (BORCAL). RCC provides a unique method of calibrating broadband atmospheric longwave and solar shortwave radiometers using techniques that reduce measurement uncertainty and better characterize a radiometer's response profile. The RCC software automatically monitors and controls many of the components that contribute to uncertainty in an instrument's responsivity. This is a user's manual and guide to the RCC software.

47 OTHER INSTRUMENTATION↗

Characterization of Calibrated Gelatin Sponge Particles in a Rabbit Renal Embolization Model

Purpose: To evaluate the level of artery occlusion, degradation periods, tissue response and vessel recanalization of calibrated gelatin sponge particles after segmental renal artery embolization. Materials and Methods: Superselective embolization of 14 adult rabbits was performed with calibrated gelatin sponge particles (150–350 μm). Two rabbits were killed immediately after the procedure (day 0). One pair of rabbits was killed on each of the following days: 1, 3, 7, 14, 28 and 56. One rabbit from each pair underwent CT angiography before embolization and killing. The pathologic changes of the embolized renal parenchyma and embolic characteristics of calibrated gelatin sponge particles were evaluated histologically and angiographically. Results: Calibrated gelatin sponge particles were distally located in interlobular artery with a dense packing on day 0. The level of occlusion paralleled the size of the particles. Partial degradation of the particles was observed on day 3, and complete degradation was observed on day 14. Vessel recanalization was observed through both CTA and histological analysis starting on day 3. Vascular inflammation responding to gelatin sponge particles was mild and subsided with the degradation of the particles. On day 28 and day 56, attenuation of embolized vessels occurred due to marked intimal proliferation, and vascular occlusion developed. Conclusions: Gelatin sponge particles of 150–350 μm produced dense and distal embolization, and were resorbed before day 14 with a mild tissue reaction. Vessel recanalization occurred secondary to the resorption of gelatin sponge particles, but permanent vascular occlusion developed due to marked intimal hyperplasia after day 28.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Understanding Calibration and Error Propagation in Longitudinal and Lateral Manganin Gauge Shock Experiments

Soda-lime glass remains elastic under shock pressures up to approximately 6.5 GPa. In this paper, soda lime glass shock experiments are used to understand the calibration and error propagation in longitudinal and lateral manganin gauge experiments. The errors in the calibration process for both longitudinal and lateral manganin gauge experiments are identified and discussed. Five soda-lime glass experiments up to 3 GPa are analyzed using this refined technique. The results show good agreement between the experimental data and the published calibration by Rosenberg and Moshel. Errors are propagated from the experimental data measurements and the assumptions that are made in the calibration, where the bulk of the error seems to come from uncertainty in the dynamic yield strength of manganin. Finally, the method presented in this paper allows for analysis of dynamic shock experiments with longitudinal and lateral manganin gauges including error propagation.

36 MATERIALS SCIENCE↗

Further Development of the Tamped Richtmyer-Meshkov Instability Method and Application to Molybdenum Dynamic Strength Calibration and Tabulation

The high pressure and high strain rate dynamic strength of Mo is experimentally and computationally investigated in the 3–20 GPa stress, 50–600 C temperature, and 10 5 –10 6 /s strain rate regimes using a modified tamped Richtmyer-Meshkov instability (RMI) method. Modifications to the tamped RMI method include a method to determine loading states during strain, a new strength calibration function based on interface shape, and a robust uncertainty quantification method. These modifications improve fidelity of the tamped RMI method, allowing evaluation of the compensating effects of pressure hardening, strain rate hardening, strain hardening, and thermal softening. The new calibration function based on interface shape is not limited to sinusoidal corrugations and could be applied to additional interface shapes. Plate impact experiments are performed at Argonne National Laboratory’s Advanced Photon Source’s Dynamic Compression Sector operated by Washington State University (DCS), driving a planar shock front through a corrugated Mo-D 2 O or Mo-C 8 F 18 interface, forcing the corrugation to significantly deform. The extent of interfacial deformation, RMI growth, is experimentally observed using X-ray phase contrast imaging at the DCS. RMI jet lengths and jet shapes are extracted from the experimental radiographs, then used to calibrate numerical simulations performed with the Sandia National Laboratories (SNL) hydrocode CTH. Mo yield strength, Y, as a function of shock pressure, P, strain rate, $\dot{\varepsilon }$, accumulated strain, ϵ, relative volumetric compression, RD , and temperature, T , is determined for each impact experiment and presented. The calibrated Mo yield strength values range 1.2–1.8 GPa, with strength generally decreasing as the impact stress increases. This trend is likely caused by thermal softening or strain localization. The tabular yield strength versus loading condition data presented in this paper can be used to fit complex strength models.

Voorhees, T. J. [Sandia National Lab. (SNL-CA), Li↗

Dynamic calibration of differential equations using machine learning, with application to turbulence models

We present a methodology for calibration of parametric ordinary and partial differential equation models, using off-the-shelf software for back-propagation in Neural Networks (NN). As a prototypical example, we consider calibration of a Reynolds-averaged Navier-Stokes (RANS) turbulence closure model, against ground truth data from direct numerical simulations (DNS) of two different turbulent flows. Numerical time integration is represented as a custom NN, where only the RANS model parameters are trainable. A loss function is defined to quantify the mismatch between the NN prediction and the ground truth over a predefined, finite time integration window. This loss function is then minimized using a gradient descent method utilizing the back-propagation algorithm. Furthermore, this dynamic approach to training is to be contrasted with a static approach, wherein a least square regression estimate for parameters is obtained in the limit of an infinitesimal time integration window. In a first test of static and dynamic approaches against ground truth data generated by the model, the former proves to be significantly faster and more accurate than the latter at recovering the parameters. When both calibration approaches are tested against DNS data, for which it is known that the model cannot achieve a perfect fit, the static approach yields a good prediction only for short times, while the dynamic approach results in physical and stable predictions over the entire integration window. After optimization of the dynamic approach for time step, spatial resolution, stability, and physics-based constraints, we obtain a 50% improvement of outcomes over those obtained from the existing, manually calibrated set of parameters, demonstrating the merits of this systematic and automated procedure.

97 MATHEMATICS AND COMPUTING↗

Electron beam test of key elements of the laser-based calibration system for the muon g - 2 experiment

We report the test of many of the key elements of the laser-based calibration system for muon g - 2 experiment E989 at Fermilab. The test was performed at the Laboratori Nazionali di Frascati's Beam Test Facility using a 450 MeV electron beam impinging on a small subset of the final g - 2 lead-fluoride crystal calorimeter system. The calibration system was configured as planned for the E989 experiment and uses the same type of laser and most of the final optical elements. We show results regarding the calorimeter's response calibration, the maximum equivalent electron energy which can be provided by the laser and the stability of the calibration system components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discussion and improvement of a blade-type XBPM with coupling suppression by compensating calibration coefficients

The Taiwan Photon Source (TPS) is a third-generation, 3-GeV storage ring with a design current of 500 mA. To monitor the photon beam stability, blade-type X-ray beam position monitors (XBPMs) are installed to record and monitor the photon beam position. The beam position coordinates involve both the X- and Y-axes, and we must consider coupling effects in the XBPM, which have to be reduced for reliability and optimum precision. This study focuses on the front-end (FE) XBPM calibration via four-blade normalization and suppression matrix compensation. The calibration results show that in the optimal measurement range of +/- 200 mu m, the coupling effect between the X and Y position is suppressed to less than a 1-mu m drift, which satisfies the high-accuracy beam position requirements for user operation. The reliability and precision of the XBPM system improved after applying the serial calibration process developed in this study, and the detailed derivation of each calibration step will be discussed here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

252 Cf yield calibration method for nuclear material accountancy and safeguards practitioners

Californium-252 is an isotope commonly encapsulated as a physically small but strong spontaneous fission neutron source for applications in industry, academia, and research. Within the nuclear safeguards community, a well-characterized 252 Cf source is often used as an accessible alternative for plutonium in calibrations measurements, which require the absolute source strength. Current methods of source strength quantification can provide an accurate estimate, approximately 1% uncertainty under optimal conditions, but are typically costly and time consuming. An alternative method was developed to determine 252 Cf source strength using passive neutron correlation counting (PNCC). The PNCC method enables institutions and facilities to perform 252 Cf source calibration measurements in-house using detection systems that are common within the nuclear safeguards community. This novel method was previously successfully demonstrated using neutron multiplicity well counters. However, the previous evaluation utilized detection systems with high neutron detection efficiencies, greater than 60%. The purpose of the current study is to extend the previous evaluation and demonstrate the feasibility of the PNCC 252 Cf calibration method for suite of coincidence counters with lower neutron detection efficiencies, between 15% and 35%, which are more commonly encountered in the field, as well as to provide a step-by-step guide to using the method. The neutron source used in this evaluation was previously certified by the National Institutes of Science and Technology (NIST), which provides a reference for the accuracy of the PNCC method. In conclusion, the present source yield calculations demonstrate excellent agreement with a NIST calibration technique and achieve a standard uncertainty below the target 1%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-term thermal stability and calibration of Type-II fiber Bragg grating array inscribed in radiation-hardened fibers

This paper investigates the long-term thermal stability of Type-II fiber Bragg grating (FBG) arrays, inscribed by femtosecond laser in radiation-hardened fiber, for potential applications as multiplexed sensors in high-temperature energy systems. The thermal stability of FBG sensors was assessed through 16 thermal cycles from room temperature (RT) to 750 ℃ about two months, involving 100 FBG sensors. The results show that the absolute temperature drift of FBG sensors can be reduced to less than 0.4 pm/day after 54 h thermal annealing process at a constant temperature of 800 ℃. As temperature sensors, the FBGs demonstrated stable performance, achieving a standard deviation (STD) of 1.8 pm (corresponding to a temperature resolution of 0.118 ℃) post-annealing. Repeated thermal cycles revealed a random drift of 2.3 pm in the FBG wavelength at RT. Polynomial fitting was explored as a calibration method to convert FBG wavelength shifts into absolute temperature measurements. By optimizing calibration temperature points (RT, 200 ℃, 400 ℃, and 750 ℃), the study shows that cubic polynomial calibration using four points yields an average R2 of 0.9997 and an RMSE of 3.58 ℃ across the entire temperature range (RT to 750 ℃). This approach represents an 11.53-fold improvement over empirical slope calibration and a 1.34-fold improvement over four-point piecewise fitting. The findings indicate that Type-II FBGs inscribed in radiation-hardened fibers can function as accurate temperature sensors, with performance on par with or exceeding that of thermocouples. With their multiplexing capability, robust signal transmission over long lead cables, and immunity to electromagnetic interference, FBG sensors offer a promising alternative to traditional electronic sensors for energy system monitoring.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

Calibrating cryogenic temperature of TEM specimens using EELS

Cryogenic Scanning/Transmission Electron Microscopy has been established as a leading method to image sensitive biological samples and is now becoming a powerful tool to understand materials' behavior at low temperatures. However, achieving precise local temperature calibration at low temperatures remains a challenge, which is especially crucial for studying phase transitions and emergent physical properties in quantum materials. In this study, we employ electron energy loss spectroscopy (EELS) to measure local cryogenic specimen temperatures. Here we use the temperature-dependent characteristics of aluminum's bulk plasmon peak in EEL spectra, which shifts due to changes in electron density caused by thermal expansion and contraction. We successfully demonstrate the versatility of this method by calibrating different liquid nitrogen cooling holders in various microscopes, regardless of whether a monochromated or non-monochromated electron beam is used. Temperature discrepancies between the actual temperature and the setpoint temperatures are identified across a range from room temperature to 100 K. This work demonstrates the importance of temperature calibrations at intermediate temperatures and presents a straightforward, robust method for calibrating local temperatures of cryogenically-cooled specimens in electron microscopes.

36 MATERIALS SCIENCE↗