Large-Format, High Throughput Photon-counting Imager
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
An experiment designed to compare neutron noise analysis techniques on subcritical assemblies using differing neutron detector designs was developed as a collaborative effort between the Institut de radioprotection et de surete nucleaire (IRSN), Los Alamos (LANL), Lawrence Livermore (LLNL), and Sandia National Laboratories. This experiment has the final goal of characterizing neutron noise analysis accuracy in determining multiplication in light water systems for various neutron detection systems. This experiment utilized the Seven Percent Critical Experiment (7uPCX) facility at Sandia National Laboratories. The 7uPCX is an assembly designed to investigate light water systems with fuel enrichment above 5% and is able to use square or hex grid plates with varying pitches.
Described herein are methods, systems, and non-transitory computer-readable media to non-destructively acquire three-dimensional profiles of cellular microbiological samples growing on the surface of a solid growth medium. Acquisitions can be performed by an optical microscope that includes a vertical scanning interferometer. The three-dimensional profiles can enable measurement of sample parameters of microcolonies, which can be made of microbial colony forming units. The methods and systems enable early and rapid detection and quantification of microbes.
A branch predictor of a processor includes one or more prediction structures, including a predicted branch address and predicted branch direction, that identify predicted branches. To reduce power consumption, the branch predictor selects one or more of the prediction structures that are not expected to provide useful branch prediction information and filters the selected structures such that the filtered structures are not used for branch prediction. The branch predictor thereby reduces the amount of power used for branch prediction without substantially reducing the accuracy of the predicted branches.
Explore the source record for details and available documents.
The thermal analysis of nuclear and ultra-rare materials plays an important role in nuclear energy, planetary, environmental, and technological settings. Heat effects associated with the sample temperature, heat capacity, phase transformation, radiation damage and crystallographic defects are some of the thermochemistry measurements made with conventional differential scanning calorimeters. However, the measurement capabilities of the of traditional DSCs are often restricted when studying limited ultra-rare accessory minerals or materials submitted to extreme conditions, such as radiation in the nuclear fuel cycle and high pressure. We investigate the usage of nanocalorimetry for the energetic analysis of nuclear or ultra-rare materials, such as irradiated materials and high-pressure phases, with an emphasis on radiation damage and heat capacity measurements. Examples of how nanocalorimetry has been previously used for phase transitions, melting, and nucleation in ultra-fast heating and cooling rates are presented. Finally, an outlook of the field and future work, including beneficial safety and environmental outcomes from the potential usage of nanocalorimetry, are shown.
To properly inform transport policy and infrastructure changes, transportation related metrics need both measured values and uncertainties of those values. Travel monitoring smartphone apps can record people's travel behavior, but trip data quality is limited by sensor errors, user labeling rates and the accuracy of inference algorithms used for travel diary creation. We discuss the use of phone app recorded travel diary data to estimate energy consumption, and propose the use of propagation of variance to find error bars for such estimates. We define energy consumption for one trip as trip length times the energy intensity per distance unit of the travel mode used. We characterize trip length errors with relative error and inferred trip mode errors with confusion matrix columns. The resulting variances of each measurement are then propagated to the final calculated energy consumption. We tested our uncertainty methods on a dataset that used phone app data combined with prompted recall, consisting of 92,234 labeled trips for over 500,000 miles. Accounting for uncertainty using expected energy intensities and variance propagation gives a dataset-wide aggregate energy consumption percent error of about 9%, within one standard deviation from the truth. Future work could involve applying similar methods to other travel diary based metrics.
To properly inform transport policy and infrastructure changes, transportation related metrics need both measured values and uncertainties of those values. Travel monitoring smartphone apps can record people's travel behavior, but trip data quality is limited by sensor errors, user labeling rates and the accuracy of inference algorithms used for travel diary creation. We discuss the use of phone app recorded travel diary data to estimate energy consumption, and propose the use of propagation of variance to find error bars for such estimates. We define energy consumption for one trip as trip length times the energy intensity per distance unit of the travel mode used. We characterize trip length errors with relative error and inferred trip mode errors with confusion matrix columns. The resulting variances of each measurement are then propagated to the final calculated energy consumption. We tested our uncertainty methods on a dataset that used phone app data combined with prompted recall, consisting of 92,234 labeled trips for over 500,000 miles. Accounting for uncertainty using expected energy intensities and variance propagation gives a dataset-wide aggregate energy consumption percent error of about 9%, within one standard deviation from the truth. Future work could involve applying similar methods to other travel diary based metrics.
The Nevada National Security Site (NNSS) provides a comprehensive bicoastal radiological and nuclear emergency response to United States Department of Energy/National Nuclear Security Administration. A major part of the support is to provide systematic radiological search for lost or stolen sources, Radiological search is a core competency of the NNSS with its origin dating back to nuclear weapons test era. Search operations from multiple platforms is the common thread among the various NNSS assets, which include Aerial Measuring System (AMS), Maritime Support Team (MST), National Capitol Response (NCR), National Search Team (NST) and Radiological Assistance Program (RAP). Information collected and analyzed during search operations add to the actionable intelligence for the law enforcement agencies and provide valuable guidance for the tactical resolution of a nuclear or radiological crisis. Search is an intelligence and situational awareness driven operation and most often called upon during a radiological emergency, however it can be brought into play to thwart a potential threat by providing monitoring and surveillance support. The Office of Nuclear Incident Response (NA-84) serves as the technical leader in responding to and resolving nuclear and radiological threats worldwide and integrates its efforts with other NNSA stakeholders (e.g., NNSA office of Defense Nuclear Non-proliferation NA-22). The response includes expertise in the areas of radiological search, render safe, and consequence management. This article will discuss the methodologies, tools, procedures, and techniques to extract maximum radiological characterization information (isotopic composition, activities for individual isotopes, threat assessment etc.) from field monitoring or Search operation data.
Explore the source record for details and available documents.
The Usibelli coal mine, which mines ultra-low sulphur subbituminous coal, is described. 5 photos.
When Pu is present in waste items as lumps, the Reals neutron coincidence signal may be bolstered by virtue of self induced fission events. This gives rise to a positive bias to the assay result and leads to a one sided contribution to the total measurement uncertainty. In the general it is not feasible to determine to magnitude of this effect experimentally and allowance for it must therefore be estimated using separate ad hoc rules. In this paper we to develop a simple model for the self-multiplication enhancement in small lumps allowing the importance of the effect in waste assay to be quantified. In addition, an approach is suggested for how to propagate an uncertainty contribution in to the final result. In conclusion: By introducing a generic scheme we have taken the first pragmatic steps to accounting for multiplication effects in the TMU in the determination of Pu-240 eff-mass by PNCC in waste. We have used a simple physical model to derive the underlying relationships needed. A first order expression suitable for small, dense lumps was set out, primarily for instructive reasons, but this is not a restriction of the method. The method is readily scaleable to material of different isotopic composition, density and a. Numerical parameters suitable for practical applications have been established and we feel the approach is fit for the intended purpose reflecting operational experiences and the general state of knowledge of waste items. (authors)
Explore the source record for details and available documents.
Explore the source record for details and available documents.
GE-Reuter-Stokes (GERS) has developed a new line of neutron proportional counters, the B10Plus+* proportional counter. The detector design is intended to serve as a cost-effective alternative to traditional {sup 3}He proportional counters in a variety of applications. The detector is a hybrid design 10B-lined tube optimized with the addition of a small quantity of 3He gas to improve the detector performance and efficiency. As a demonstration of the B10Plus+* detector, GERS has constructed a Uranium Neutron Collar (UNCL) system consisting of B-10Plus+* proportional counters. GERS has designed and built a demonstration UNCL system intended to match the performance of a Type-I UNCL design in Pressurized Water Reactor (PWR) geometry operating in thermal mode. GERS offered their system on loan to the International Atomic Energy Agency (IAEA) Safeguards Division of Technical and Scientific Services for an assessment of the detector technology and the demonstration system. We have characterized the demonstration UNCL system and compared its performance with a traditional Type-I UNCL design in regular use by the IAEA. This paper summarizes our findings and observations during the characterization and testing activity. (authors)
Research and development into applications for improving equipment condition monitoring programs at nuclear facilities has been around since the 1990s. However, while the field has moved from using data-driven machine learning (ML) algorithms for detection and prediction of equipment degradation and failure to prognostic capabilities, these applications are still not widely used in the U.S. nuclear industry. Additionally, there has been significant effort in designing both data-driven and physics-based artificial intelligence (AI) and ML models for many other potential applications in the nuclear industry, including cyber intrusion detection systems (IDS). However, as the last twenty years in condition-based maintenance research has shown us, there are significant hurdles that must be overcome for deployment of IDS on plant systems. This paper provides a discussion on the practical recommendations that researchers should consider for successful adoption of AI/ML IDS in the nuclear industry.
Precision in measuring particle energies is crucial to understand the intricacies of high-energy physics beyond the standard model. For the REDTOP experiment to detect η/η´ mesons potentially decaying into dark-matter particles not yetdiscovered, it is essential to have accurate measurements through sophisticated and innovative detector technology built with special properties. The ADRIANO2 (A Dual Readout Integrally Active Non-segmented Option) Calorimeter Prototype plays a pivotal role in advancing detection capabilities, offering the potential to enhance the particle identification procedure. This study delves into the characterization of the ADRIANO2 prototype’s light yield with the ultimate goal of contributing to broader high-energy physics objectives. To estimate the light yield for the ADRIANO2 prototype, we must calibrate the light sensors as well as collect data from beams of known properties. Several prototypes of the ADRIANO2 detector have been tested at the Mtest Facility at Fermi National Accelerator Laboratory in the last few years. This paper attempts to summarize the calibration of one such ADRIANO2 prototype to estimate its experimental performance.
The US Department of Energy (DOE) is often faced with the need to evaluate radionuclides at low concentrations. When site sample data are likely to be close to threshold activity concentrations of interest, then the means by which the radiochemical analysis is performed and reported is critical. This situation can occur when differentiating from zero (presence/absence) for radionuclides that do not occur naturally, close comparison with environmental background for naturally occurring radionuclides, close comparison with a risk- or dose-based threshold concentrations of interest, or even comparisons across studies. There are several analytical issues that are of concern, but the two that appear to cause incorrect decisions to be made most often involve establishing detection limits and subtracting ambient background conditions in the laboratory. These issues are not critical when radionuclide activity concentrations are large relative to thresholds of concern, but they seem to be poorly understood when it matters. When the comparisons are important and are likely to be close to a threshold of interest, then the general contract with the analytical laboratories needs to be changed so that the right or appropriate data are obtained. The concern is that important decisions are made incorrectly more often as greater scrutiny is placed on DoE's radionuclide cleanup or monitoring decisions by the public and other stakeholders. Examples are presented of problems that have been observed for different projects, both within and outside the realm of DOE and NRC remediation and radioactive waste disposal problems, and solutions are offered that should lead to better data from which important decisions need to be made. The first example is from Los Alamos National Laboratory (LANL) and involves radionuclide concentrations in soil and rock beneath LANL's Material Disposal Area (MDA) G. An initial review of the data led to a conclusion that americium and plutonium are a long way present beneath MDA G. A more thorough review of the data that accounted properly for ambient background and the detection limits that had been established led to the opposite conclusion. Another example is from the Nevada National Security Site where tritium results from one of the wells were unexpectedly high. Proper understanding and analysis of ambient background led to the conclusion that the increased concentrations were not so obvious, and that a different contract with the analytical laboratory was needed to provide more appropriate data to support a better determination. Other examples are used from regulatory review of projects in Nevada, where background levels and secular equilibrium for naturally occurring radionuclides are not established correctly because of analytical issues. The same basic issues have also been found to create difficulties analyzing historical data from the West Valley Demonstration Project. There is evidence in the data that the apparent lack of secular equilibrium where it is expected to exist is related to ambient background subtraction or other analytical issues. A final example is presented for analysis of Tc-99 in samples of depleted uranium. In this case, two different studies that were performed only three months apart provide quite different results. The US Environmental Protection Agency (EPA) established the data quality objectives (DQO) process in the mid-1980's to establish decision performance criteria for data collection. EPA guidance (EPA G-4, for example) clearly distinguishes between DQOs and measurement performance objectives (MQOs) that should be addressed for laboratory analysis of samples. The language of DQOs and MQOs has become confused over time it seems, and the subsequent effects seem to include a lack of attention to decision performance and a routine approach to measurement quality. In order to better address radionuclide sample analysis when the concentrations are close to thresholds of concern, which might be zero for some radionuclides, background for others, and risk-based thresholds for yet others, it is important that routine laboratory analysis methods are adjusted, and that the project team and the laboratory work closely together to ensure that the data meets the MQO requirements of laboratory analysis and reporting of results, and that the MQOs effectively support project-specific DQOs. This basic approach will be applied in Los Alamos in the coming year to the collection of moisture data from underneath MDA T that will be analyzed for americium and neptunium isotopes. Proper understanding of the radiochemistry methods and reporting, and of appropriate statistical methods is critical to the success of such projects, ensuring that the right decisions are made. (authors)