Search NASA⌕ Search

SEARCH · Search NASA

Results for “DETECTOR PHYSICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Monolithic active pixel matrix with binary counters (MAMBO III) ASIC

Monolithic Active Matrix with Binary Counters (MAMBO) is a counting ASIC designed for detecting and measuring low energy X-rays from 6-12keV. Each pixel contains analogue functionality implemented with a charge preamplifier, CR-RC{sup 2} shaper and a baseline restorer. It also contains a window comparator which can be trimmed by 4 bit DACs to remove systematic offsets. The hits are registered by a 12 bit ripple counter which is reconfigured as a shift register to serially output the data from the entire ASIC. Each pixel can be tested individually. Two diverse approaches have been used to prevent coupling between the detector and electronics in MAMBO III and MAMBO IV. MAMBO III is a 3D ASIC, the bottom ASIC consists of diodes which are connected to the top ASIC using {mu}-bump bonds. The detector is decoupled from the electronics by physically separating them on two tiers and using several metal layers as a shield. MAMBO IV is a monolithic structure which uses a nested well approach to isolate the detector from the electronics. The ASICs are being fabricated using the SOI 0.2 {micro}m OKI process, MAMBO III is 3D bonded at T-Micro and MAMBO IV nested well structure was developed in collaboration between OKI and Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing the CDF's B physics program with a faster data acquisition system.

The physics program of Run II at the Tevatron includes precision electroweak measurements such as the determination of the top quark and W boson masses; bottom and charm physics including the determination of the B{sub s} and D{sup 0} mixing parameters; studies of the strong interaction; and searches for the Higgs particle, supersymmetric particles, hidden space-time dimensions and quark substructure. All of these measurements benefit from a high-resolution tracking detector. Most of them rely heavily on the efficient identification of heavy flavored B hadrons by detection of displaced secondary vertices, and are enhanced by the capability to trigger on tracks not coming from the primary vertex. This is uniquely provided by CDF's finely-segmented silicon detectors surrounding the interaction region. Thus CDF experiment's physics potential critically depends on the performance of its silicon detectors. The CDF silicon detectors were designed to operate up to 2-3 fb{sup -1} of accumulated pji collisions, with an upgrade planned thereafter. However, the upgrade project was canceled in 2003 and Run II has been extended through 2011, with an expected total delivered integrated luminosity of 12 fb{sup -1} or more. Several preventive measures were taken to keep the original detector operational and maintain its performance. The most important of these are the decrease in the operating temperature of the detector, which reduces the impact of radiation exposure, and measures to minimize damage due to integrated radiation dose, thermal cycles, and wire bond resonance conditions. Despite these measures the detectors operating conditions continue to change with issues arising from radiation damage to the sensors, aging infrastructure and electronics. These, together with the basic challenges posed by the inaccessibility of the detector volume and large number (about 750 thousand) of readout channels, make the silicon detector operations the single most complex and high priority job in the CDF experiment.

43 PARTICLE ACCELERATORS↗

Search for Anomalous Production of Photon + Jets + Missing Transverse Energy in $p\bar{p}$ Collisions at $\sqrt{s}=1.96$~TeV Using the CDF II Detector

A model-independent signature-based search for physics beyond the Standard Model is performed in the photon + jets + missing transverse energy channel in \ppbar collisions at a center of mass energy of 1.96 TeV using the CDF II detector. Events with a photon + jets are predicted by the Standard Model and also by many theoretical models beyond the Standard Model. In the Standard Model, the main mechanisms for photon + jets production include quark-antiquark annihilation and quark-gluon scattering. No intrinsic missing transverse energy is present in any of these Standard Model processes. In this search, photon + $\geq$1 jet and photon + $\geq$2 jet events are analyzed with and without a minimum requirement on the missing transverse energy. Numerous mass distributions and kinematic distributions are studied and no significant excess over the background prediction is found. All results indicate good agreement with expectations of the Standard Model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Two-Stage Cryogenic HEMT-Based Amplifier for Low-Temperature Detectors

To search for dark matter candidates with masses below $\mathcal{O}$ (MeV), the SPLENDOR (Search for Particles of Light dark mattEr with Narrow-gap semiconDuctORs) experiment is developing novel narrow-bandgap semiconductors with electronic bandgaps on the order of 1–100 meV. In order to detect the charge signal produced by scattering or absorption events, SPLENDOR has designed a two-stage cryogenic HEMT-based amplifier with an estimated charge resolution approaching the single-electron level. A low-capacitance (~ 1.6 pF) HEMT is used as a buffer stage at T = 10 mK to mitigate effects of stray capacitance at the input. The buffered signal is then amplified by a higher-capacitance (~ 200 pF) HEMT amplifier stage at T = 4 K. Importantly, the design of this amplifier makes it usable with any insulating material—allowing for rapid prototyping of a variety of novel detector materials. Here, we present the two-stage cryogenic amplifier design, preliminary voltage noise performance, and estimated charge resolution of 7.2 electrons.

47 OTHER INSTRUMENTATION↗

Solid State Streak Camera Prototype Electronic Performance Testing and Characterization

Streak Cameras are an essential diagnostic tool used in shock physics and high energy density physics experiments. Such experiments require well calibrated temporally resolved diagnostics for studying events that occur in the nanosecond to microsecond time scales. Although streak cameras are among the most common detectors used within the high energy density physics community, they require frequent calibration and typically lack reproducibility in the fine detail. A solid state device with similar temporal performance characteristics could provide several advantages to current streak camera systems by utilizing discrete spatial resolution set by the sensor diodes. National Security Technologies (NSTec) has built a multi-channel solid state streak camera (SSSC) prototype, in collaboration with Sandia National Laboratories, as part of an ongoing project to develop the technology to a level competitive with analog streak cameras. The device concept and results from electronic testing of our first prototypes will be discussed in this manuscript. These measurements will be used as a base for future SSSC development projects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Increasing the energy dynamic range of solid-state nuclear track detectors using multiple surfaces

Solid-state nuclear track detectors, such as CR-39, are widely used in physics and in many inertial confinement fusion (ICF) experiments. In the ICF experiments, the particles of interest, such as D{sup 3}He-protons, have ranges of order of the detector thickness. In this case, the dynamic range of the detector can be extended by recording data on both the front and back sides of the detector. Higher energy particles which are undetectable on the front surface can then be measured on the back of the detector. Studies of track formation under the conditions on the front and back of the detector reveal significant differences. Distinct front and back energy calibrations of CR-39 are therefore necessary and are presented for protons. Utilizing multiple surfaces with additional calibrations can extend the range of detectable energies on a single piece of CR-39 by up to 7-8 MeV. The track formation process is explored with a Monte Carlo code, which shows that the track formation difference between front and back is due to the non-uniform ion energy deposition in matter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutrino Scattering in the NOvA Near Detector

aNOvA is a long-baseline accelerator-based neutrino experiment based in the USA. NOvA uses an intense neutrino beam produced at Fermilab’s accelerator complex to make physics measurements of neutrino oscillations, neutrino cross sections, and much more. For its physics goals, NOvA uses two functionally-identical detectors. The Near Detector (ND) is situated at Fermilab, 1 km from the neutrino target and the Far Detector (FD) is located at Ash River, MN, a distance of 810 km from the neutrino source. The ND receives a high statistics neutrino flux which gives a unique opportunity for high-precision neutrino cross-section measurements and is used as a control for the oscillation analyses. In this talk/poster, I will give an overview of the NOvA experiment. I will also talk about the current and future status of the NOvA’s cross-section physics program.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Secondary-Source Core Reload Modeling with VERA

The CASL reactor simulation package VERA has been adapted to provide high-fidelity simulation capabilities for modeling source range detector response during subcritical reactor configurations. New features include the activation and shuffling of secondary-source assemblies, use of burned fuel neutron emission data from the ORIGEN depletion solver to the MPACT deterministic neutron transport solver, allowance of user-defined sources in MPACT based on material composition, ability to solve the subcritical source-driven system with neutron multiplication using the MPACT diffusion solver, and transfer of the calculated fission source from MPACT to the continuous-energy Monte Carlo solver Shift for final detector response evaluation using the CADIS methodology for variance reduction. These new capabilities were benchmarked against Watts Bar Unit 1 plant operating data for the first few fuel loading steps and were found to demonstrate excellent agreement with the measured data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Athermal Energy Loss from X-rays Deposited in Thin Superconducting Films on Solid Substrates

When energy is deposited in a thin-film cryogenic detector, such as from the absorption of an X-ray, an important feature that determines the energy resolution is the amount of athermal energy that can be lost to the heat bath prior to the elementary excitation systems coming into thermal equilibrium. This form of energy loss will be position-dependent and therefore can limit the detector energy resolution. An understanding of the physical processes that occur when elementary excitations are generated in metal films on dielectric substrates is important for the design and optimization of a number of different types of low temperature detector. We have measured the total energy loss in one relatively simple geometry that allows us to study these processes and compare measurements with calculation based upon a model for the various di.erent processes. We have modeled the athermal phonon energy loss in this device by finding an evolving phonon distribution function that solves the system of kinetic equations for the interacting system of electrons and phonons. Using measurements of device parameters such as the Debye energy and the thermal di.usivity we have calculated the expected energy loss from this detector geometry, and also the position-dependent variation of this loss. We have also calculated the predicted impact on measured spectral line-shapes, and shown that they agree well with measurements. In addition, we have tested this model by using it to predict the performance of a number of other types of detector with di.erent geometries, where good agreement is also found.

Kozorezov, Alexander G.↗

Electron pulse-dilation diagnostic instruments

During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5–30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. In this paper we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

47 OTHER INSTRUMENTATION↗

First Observation of Cyclotron Radiation from MeV-Scale e ± following Nuclear β Decay

We present an apparatus for detection of cyclotron radiation yielding a frequency-based β ± kinetic energy determination in the 5 keV to 2.1 MeV range, characteristic of nuclear β decays. The cyclotron frequency of the radiating β particles in a magnetic field is used to determine the β energy precisely. Our work establishes the foundation to apply the cyclotron radiation emission spectroscopy (CRES) technique, developed by the Project 8 Collaboration, far beyond the 18-keV tritium endpoint region. We report initial measurements of β – ’s from 6 He and β + ’s from 19 Ne decays to demonstrate the broadband response of our detection system and assess potential systematic uncertainties for β spectroscopy over the full (MeV) energy range. To our knowledge, this is the first direct observation of cyclotron radiation from individual highly relativistic β’s in a waveguide. Furthermore, this work establishes the application of CRES to a variety of nuclei, opening its reach to searches for new physics beyond the TeV scale via precision β-decay measurements.

43 PARTICLE ACCELERATORS↗

Beyond the Standard Model physics prospects at DUNE

The Deep Underground Neutrino Experiment (DUNE) is an international project for neutrino physics and proton-decay searches, currently in the design and construction stages. Once built, DUNE will consist of two detectors exposed to the world's most intense neutrino beam. The near detector will record neutrino interactions near the beginning of the beamline, at Fermilab. The other, much larger, detector, comprising four 17-kton liquid argon time projection chambers (LArTPCs), will be installed at a depth of 1.5 km at the Sanford Underground Research Facility in South Dakota, about 1300 km away from the neutrino source.The unique combination of the high-intensity neutrino beam with DUNE's high-resolution near detector system and massive LArTPC far detector enables a variety of probes of BSM physics, either novel or with unprecedented sensitivity, from the potential discovery of new particles (sterile neutrinos or dark matter), to precision tests of the three-flavour neutrino mixing paradigm, or the detailed study of rare processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TH-CD-201-07: Experimentally Investigating Proton Energy Deposition On the Microscopic Scale Using Fluorescence Nuclear Track Detectors

Purpose: In order to further understand the interplay between proton physics and radiobiology it is necessary to consider proton energy deposition on the microscopic scale. In this work we used Fluorescent Nuclear Track Detectors (FNTDs) to experimentally investigate proton energy deposition, track-by-track. Methods: We irradiated 8×4×0.5mm{sup 3} FNTD chips (Landauer Inc) at seven water depths along a pristine proton Bragg peak with range=12cm. After irradiation, the FNTDs were scanned using a confocal microscope (FV1200, Olympus) with a high-power red laser and an oil-immersion objective lens (UPLSAPO60XO, NA=1.35). 10 slice image stacks were acquired with a slice-thickness of 2µm at multiple positions across each FNTD. Image-based analyses of track radius and track “mass” (integrated signal intensity) were performed using trackpy. For comparison, Monte Carlo simulated data were obtained using TOPAS and TOPAS-nBio. Results: Excellent correlation was observed between median track mass and TOPAS dose-averaged linear energy transfer. The resolution of the imaging system was determined insufficient to detect a relationship between track radius and exposure depth. Histograms of track mass (i) displayed strong repeatability across positions within an FNTD and (ii) varied in peak position and shape as a function of depth. TOPAS-nBio simulations implemented on the nanometer scale using physics lists from GEANT4-DNA yielded energy deposition distributions for individual protons and electrons scored within a virtual FNTD. Good agreement was found between these simulated datasets and the FNTD track mass distributions. Conclusion: Robust experimental measurements of the integral energy deposited by individual proton tracks can be performed using FNTDs. Monte Carlo simulations offer an exceedingly powerful approach to the quantification of proton energy deposition on the microscopic scale, but whilst they have been well validated at the macroscopic level, their microscopic validation is far from complete. Our results demonstrate that FNTD-based study can play an important role in addressing this deficit. Tracy Underwood gratefully acknowledges the support of the European Commission under an FP7 Marie Curie International Outgoing Fellowship for Career Development (#630064).

60 APPLIED LIFE SCIENCES↗

The Pandora multi-algorithm approach to automated pattern recognition in LAr TPC detectors

Pattern recognition is the identification of structures and regularities in data. In high energy physics, it is a vital stage in the reconstruction of events recorded by fine-granularity detectors. The development and operation of Liquid Argon Time Projection Chambers (LAr TPCs) for neutrino physics has created a need for new approaches to pattern recognition, in order to fully exploit the superb imaging capabilities offered by this technology. Whereas the human brain excels at identifying features in the recorded events, it is a significant challenge to develop an automated solution. The Pandora Software Development Kit (SDK) provides functionality to aid the process of designing, implementing and running pattern recognition algorithms. In particular, it promotes the use of a multi-algorithm approach to pattern recognition: individual algorithms each aim to address a specific task in a particular topology; a series of many tens of algorithms then carefully build-up a picture of the event and, together, provide a robust automated pattern recognition solution. Building on successful use of the Pandora SDK for pattern recognition at collider experiments, a sophisticated chain of algorithms has been created to perform pattern recognition for neutrino experiments utilising LAr TPCs like MicroBooNE. The input to the Pandora pattern recognition is a list of 2D Hits. The output from the chain of over 70 algorithms is a hierarchy of reconstructed 3D Particles, each with an identified particle type, vertex and direction. In this document, we present details of the Pandora pattern recognition algorithms used to reconstruct cosmic-ray and neutrino events in LAr TPCs. We also present metrics that assess the current reconstruction performance using simulated data from MicroBooNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Space-based gravitational-wave detectors can determine the thermal history of the early Universe

It is shown that space-based gravitational-wave detectors such as DECIGO and/or the Big Bang Observer will provide us with invaluable information on the cosmic thermal history after inflation, and they will be able to determine the reheat temperature T{sub R} provided that it lies in the range preferred by the cosmological gravitino problem, T{sub R}{approx}10{sup 5-9} GeV. Therefore it is strongly desired that they will be put into practice as soon as possible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗