Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

TPSAS-NF1676L-27431-DND

The Protocol Actions for Astronaut Dose Calculations were developed to provide participating agencies an opportunity to compare results best on their best practices. The results presented here were calculated using the HZETRN space radiation transport code and human response models developed for the On-Line Tool for the Assessment of Radiation in Space (OLTARIS). Two sets of results are presented: - The first set, labelled TARIS 4.0, were calculated using the latest version of the space radiation analysis tools developed for OLTARIS, but not yet incorporated into OLTARIS. - The second set, labelled OLTARIS (TARIS version 3.5), were calculated with the current version of OLTARIS and TIM participants should be able to reproduce these results.

Martha Clowdsley↗

SU-F-J-140: Using Handheld Stereo Depth Cameras to Extend Medical Imaging for Radiation Therapy Planning

Purpose: A correct body contour is essential for the accuracy of dose calculation in radiation therapy. While modern medical imaging technologies provide highly accurate representations of body contours, there are times when a patient’s anatomy cannot be fully captured or there is a lack of easy access to CT/MRI scanning. Recently, handheld cameras have emerged that are capable of performing three dimensional (3D) scans of patient surface anatomy. By combining 3D camera and medical imaging data, the patient’s surface contour can be fully captured. Methods: A proof-of-concept system matches a patient surface model, created using a handheld stereo depth camera (DC), to the available areas of a body contour segmented from a CT scan. The matched surface contour is then converted to a DICOM structure and added to the CT dataset to provide additional contour information. In order to evaluate the system, a 3D model of a patient was created by segmenting the body contour with a treatment planning system (TPS) and fabricated with a 3D printer. A DC and associated software were used to create a 3D scan of the printed phantom. The surface created by the camera was then registered to a CT model that had been cropped to simulate missing scan data. The aligned surface was then imported into the TPS and compared with the originally segmented contour. Results: The RMS error for the alignment between the camera and cropped CT models was 2.26 mm. Mean distance between the aligned camera surface and ground truth model was −1.23 +/−2.47 mm. Maximum deviations were < 1 cm and occurred in areas of high concavity or where anatomy was close to the couch. Conclusion: The proof-of-concept study shows an accurate, easy and affordable method to extend medical imaging for radiation therapy planning using 3D cameras without additional radiation. Intel provided the camera hardware used in this study.

60 APPLIED LIFE SCIENCES↗

Dosimetric characterization of a microDiamond detector in clinical scanned carbon ion beams

Purpose: To investigate for the first time the dosimetric properties of a new commercial synthetic diamond detector (PTW microDiamond) in high-energy scanned clinical carbon ion beams generated by a synchrotron at the CNAO facility. Methods: The detector response was evaluated in a water phantom with actively scanned carbon ion beams ranging from 115 to 380 MeV/u (30–250 mm Bragg peak depth in water). Homogeneous square fields of 3 × 3 and 6 × 6 cm{sup 2} were used. Short- and medium-term (2 months) detector response stability, dependence on beam energy as well as ion type (carbon ions and protons), linearity with dose, and directional and dose-rate dependence were investigated. The depth dose curve of a 280 MeV/u carbon ion beam, scanned over a 3 × 3 cm{sup 2} area, was measured with the microDiamond detector and compared to that measured using a PTW Advanced Markus ionization chamber, and also simulated using FLUKA Monte Carlo code. The detector response in two spread-out-Bragg-peaks (SOBPs), respectively, centered at 9 and 21 cm depths in water and calculated using the treatment planning system (TPS) used at CNAO, was measured. Results: A negligible drift of detector sensitivity within the experimental session was seen, indicating that no detector preirradiation was needed. Short-term response reproducibility around 1% (1 standard deviation) was found. Only 2% maximum variation of microDiamond sensitivity was observed among all the evaluated proton and carbon ion beam energies. The detector response showed a good linear behavior. Detector sensitivity was found to be dose-rate independent, with a variation below 1.3% in the evaluated dose-rate range. A very good agreement between measured and simulated Bragg curves with both microDiamond and Advanced Markus chamber was found, showing a negligible LET dependence of the tested detector. A depth dose curve was also measured by positioning the microDiamond with its main axis oriented orthogonally to the beam direction. A strong distortion in Bragg peak measurement was observed, confirming manufacturer recommendation on avoiding such configuration. Very good results were obtained for SOBP measurements, with a difference below 1% between measured and TPS-calculated doses. The stability of detector sensitivity in the observation period was within the experimental uncertainty. Conclusions: Dosimetric characterization of a PTW microDiamond detector in high-energy scanned carbon ion beams was performed. The results of the present study showed that this detector is suitable for dosimetry of clinical carbon ion beams, with a negligible LET and dose-rate dependence.

07 ISOTOPE AND RADIATION SOURCES↗

Radiation dose rate distributions of spent fuel dry casks estimated with MAVRIC based on detailed geometry and continuous-energy models

This study presents a detailed comparison of the dose rate distributions of a dry TN–32 fuel cask with two geometry models and two cross-sectional datasets. The accuracies of radiation dose rate estimation and computational efficiencies of each geometry model with two cross-sectional data-sets are compared. The use of automated variance reduction techniques can significantly improve the computational efficiency of such a realistic, deep penetration problem that involves radiation transport from different volumetric sources, thereby eliciting only a small statistical error. Monaco with Automated Variance Reduction using Importance Calculations (MAVRIC) is a computational sequence within the SCALE 6.2 code package based on consistent adjoint driven importance sampling (CADIS), a type of automated variance reduction technique. Homogenous and full fuel assembly models are built herein, and two nuclear cross-section libraries (V7–200N47G and continuous energy) are applied in this work. Based on the detailed comparisons, we found that neutron dose rate estimation is more dependent on geometry modeling than on cross-section data. For neutron-induced gamma rays, the dose rate distribution depends on both the spatial self-shielding effect and the cross-section library. The primary gamma rays respectively contribute to the total dose rate by ~91% and ~ 99% on side and top surfaces, and the dose rate accuracy is more dependent on the cross-section library than on geometry modeling. In terms of the computation efficiency and efforts spent on geometry modeling, the homogenous fuel assembly model with the MG library can produce an acceptable dose rate distribution, but the detailed fuel assembly model with the continuous-energy library is required for more precise dose rate estimation.

61 RADIATION PROTECTION AND DOSIMETRY↗

NIRP Core Software Suite v.5.1

SAND2023-06610O The Nuclear Incident Response Program (NIRP) Core Software Suite is a set of code that supports multiple applications. It includes miscellaneous base code for data objects, mathematic equations, and user interface components that are used for developing large applications, including those used for data management. Among the types of applications: • Analyst Manager is used for managing contact information, which is also often included in reports and identifies the owners of calculations. • Radionuclide Viewer provides access to the Dose Coefficient File Package (DCFPAK) radiological data, and it complements the Mixture Manager tool. • Mixture Manager creates and manages radionuclides mixtures that are commonly used in other applications. • High Explosive Manager manages explosives and properties. • Chart Viewer is used for data charts such as meteorology charts and other charts specific to data needs. • Unit Converter converts numeric values to/from different units. This package includes object-oriented base code such as data objects describing the date, time, and location of an event; weather conditions; data types that support predefined ranges of values; a unit library, and others. The package also includes mathematic equations such as determining the distance between two points; erf functions; factorial functions; incidence fractions of probit curves; and others. Other features are customized user interface components for text fields; unit selectors (combo boxes); menus; panels; bug-tracking; and automated checks for software updates. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Collins, Ian↗

Transient Photocurrent From High-Voltage Vertical GaN Diodes Irradiated With Electrons: Experiments and Simulations

Radiation-hard high-voltage vertical GaN p-n diodes are being developed for use in power electronics subjected to ionizing radiation. Here, we present a comparison of the measured and simulated photocurrent response of diodes exposed to ionizing irradiation with 70 keV and 20 MeV electrons at dose rates in the range of 1.4x10 7 - 5.0x10 8 rad(GaN)/s. The simulations correctly predict the trend in measured steady-state photocurrent and agree with experimental results within a factor of 2. Furthermore, simulations of the transient photocurrent response to dose rates with uniform and non-uniform ionization depth profiles uncover the physical processes involved that cannot be otherwise experimentally observed due to orders of magnitude larger RC time constant of the test circuit. The simulations were performed using an Exploratory Physics Development code developed at Sandia National Laboratories. The code offers the capability to include defect physics under more general conditions, not included in commercially available software packages, extending the applicability of the simulations to different types of radiation environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiological characterization and Decommissioning of Research and Power Reactors - 15602

The production of the detailed activity and dose rate atlases (ADAs) is one of the indispensable measures in the decommissioning process of nuclear reactors which allows to determine the radiation field for optimal radiation protection as well as to quantify and characterize nuclear waste for disposal. High-detailed simulation models capable of performing neutron and radiation transport calculations at different levels of precision and details are applied for this purpose. Within the framework of the research project 'Decommissioning of Research and Power Reactors', funded by the German Federal Ministry of Education and Research (BMBF), and implemented by the Institute of Nuclear Engineering and Technology Transfer (NET) -RWTH Aachen, sophisticated simulation tools are developed. The enhances capability of these tools for the generation of the activity and dose rate distribution are tested and demonstrated on the shutdown German research reactor FRJ-2. To achieve the project goal different computational steps were required: 1. Development of a calculational CAD-based model for Monte Carlo neutron and gamma transport simulation using converter tool McCad 2. Design of the neutron source which reproduce the neutron distribution leaving the core 3. Enhancement of the simulation performance by using the hybrid deterministic Monte Carlo variance reduction methods 4. Calculation of N-flux distribution in the entire geometry 5. Development of couple codes between MCNP5 and the activation code ORIGEN2.2 This paper describes the main significant project milestones. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Poster — Thur Eve — 14: Improving Tissue Segmentation for Monte Carlo Dose Calculation using DECT

Purpose: To improve Monte Carlo dose calculation accuracy through a new tissue segmentation technique with dual energy CT (DECT). Methods: Electron density (ED) and effective atomic number (EAN) can be extracted directly from DECT data with a stoichiometric calibration method. Images are acquired with Monte Carlo CT projections using the user code egs-cbct and reconstructed using an FDK backprojection algorithm. Calibration is performed using projections of a numerical RMI phantom. A weighted parameter algorithm then uses both EAN and ED to assign materials to voxels from DECT simulated images. This new method is compared to a standard tissue characterization from single energy CT (SECT) data using a segmented calibrated Hounsfield unit (HU) to ED curve. Both methods are compared to the reference numerical head phantom. Monte Carlo simulations on uniform phantoms of different tissues using dosxyz-nrc show discrepancies in depth-dose distributions. Results: Both SECT and DECT segmentation methods show similar performance assigning soft tissues. Performance is however improved with DECT in regions with higher density, such as bones, where it assigns materials correctly 8% more often than segmentation with SECT, considering the same set of tissues and simulated clinical CT images, i.e. including noise and reconstruction artifacts. Furthermore, Monte Carlo results indicate that kV photon beam depth-dose distributions can double between two tissues of density higher than muscle. Conclusions: A direct acquisition of ED and the added information of EAN with DECT data improves tissue segmentation and increases the accuracy of Monte Carlo dose calculation in kV photon beams.

07 ISOTOPE AND RADIATION SOURCES↗

Fast Biological Modeling for Voxel-based Heavy Ion Treatment Planning Using the Mechanistic Repair-Misrepair-Fixation Model and Nuclear Fragment Spectra

Purpose: The physical and biological differences between heavy ions and photons have not been fully exploited and could improve treatment outcomes. In carbon ion therapy, treatment planning must account for physical properties, such as the absorbed dose and nuclear fragmentation, and for differences in the relative biological effectiveness (RBE) of ions compared with photons. We combined the mechanistic repair-misrepair-fixation (RMF) model with Monte Carlo-generated fragmentation spectra for biological optimization of carbon ion treatment plans. Methods and Materials: Relative changes in double-strand break yields and radiosensitivity parameters with particle type and energy were determined using the independently benchmarked Monte Carlo damage simulation and the RMF model to estimate the RBE values for primary carbon ions and secondary fragments. Depth-dependent energy spectra were generated with the Monte Carlo code FLUKA for clinically relevant initial carbon ion energies. The predicted trends in RBE were compared with the published experimental data. Biological optimization for carbon ions was implemented in a 3-dimensional research treatment planning tool. Results: We compared the RBE and RBE-weighted dose (RWD) distributions of different carbon ion treatment scenarios with and without nuclear fragments. The inclusion of fragments in the simulations led to smaller RBE predictions. A validation of RMF against measured cell survival data reported in published studies showed reasonable agreement. We calculated and optimized the RWD distributions on patient data and compared the RMF predictions with those from other biological models. The RBE values in an astrocytoma tumor ranged from 2.2 to 4.9 (mean 2.8) for a RWD of 3 Gy(RBE) assuming (α/β){sub X} = 2 Gy. Conclusions: These studies provide new information to quantify and assess uncertainties in the clinically relevant RBE values for carbon ion therapy based on biophysical mechanisms. We present results from the first biological optimization of carbon ion radiation therapy beams on patient data using a combined RMF and Monte Carlo damage simulation modeling approach. The presented method is advantageous for fast biological optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Molecular Imaging of the ATM Kinase Activity

Purpose: Ataxia telangiectasia mutated (ATM) is a serine/threonine kinase critical to the cellular DNA-damage response, including from DNA double-strand breaks. ATM activation results in the initiation of a complex cascade of events including DNA damage repair, cell cycle checkpoint control, and survival. We sought to create a bioluminescent reporter that dynamically and noninvasively measures ATM kinase activity in living cells and subjects. Methods and Materials: Using the split luciferase technology, we constructed a hybrid cDNA, ATM-reporter (ATMR), coding for a protein that quantitatively reports on changes in ATM kinase activity through changes in bioluminescence. Results: Treatment of ATMR-expressing cells with ATM inhibitors resulted in a dose-dependent increase in bioluminescence activity. In contrast, induction of ATM kinase activity upon irradiation resulted in a decrease in reporter activity that correlated with ATM and Chk2 activation by immunoblotting in a time-dependent fashion. Nuclear targeting improved ATMR sensitivity to both ATM inhibitors and radiation, whereas a mutant ATMR (lacking the target phosphorylation site) displayed a muted response. Treatment with ATM inhibitors and small interfering (si)RNA-targeted knockdown of ATM confirm the specificity of the reporter. Using reporter expressing xenografted tumors demonstrated the ability of ATMR to report in ATM activity in mouse models that correlated in a time-dependent fashion with changes in Chk2 activity. Conclusions: We describe the development and validation of a novel, specific, noninvasive bioluminescent reporter that enables monitoring of ATM activity in real time, in vitro and in vivo. Potential applications of this reporter include the identification and development of novel ATM inhibitors or ATM-interacting partners through high-throughput screens and in vivo pharmacokinetic/pharmacodynamic studies of ATM inhibitors in preclinical models.

60 APPLIED LIFE SCIENCES↗

Parametric Evaluation of SiC/SiC Composite Cladding with UO 2 Fuel for LWR Applications: Fuel Rod Interactions and Impact of Nonuniform Power Profile in Fuel Rod

SiC/SiC composites are candidates for accident tolerant fuel cladding in light water reactors. In the extreme nuclear reactor environment, SiC-based fuel cladding will be exposed to neutron damage, significant heat flux, and a corrosive environment. Here, to ensure reliable and safe operation of accident tolerant fuel cladding concepts such as SiC-based materials, it is important to assess thermo-mechanical performance under in-reactor conditions including irradiation and realistic temperature distributions. The effect of non-uniform dimensional changes caused by neutron irradiation with spatially varying temperatures, along with the closing of the fuel–cladding gap, on the stress development in the cladding over the course of irradiation were evaluated. The effect of non-uniform circumferential power profile in the fuel rod on the mechanical performance of the cladding is also evaluated. These analyses have been performed using the BISON fuel performance modeling code and the commercial finite element analysis code Abaqus. A constitutive model is constructed and solved numerically to predict the stress distribution in the cladding under normal operating conditions. The dependence of dimensions and thermophysical properties on irradiation dose and temperature has been incorporated into the models. Initial scoping results from parametric analyses provide time varying stress distributions in the cladding as well as the interaction of fuel rod with the cladding under different conditions of initial fuel rod-cladding gap and linear heat rate. It is found that a non-uniform circumferential power profile in the fuel rod may cause significant lateral bowing in the cladding, and motivates further analysis and evaluation.

Accident tolerant fuel↗

Skyshine Calculations for a Large Spent Nuclear Fuel Storage Facility with SCALE 6.2.3

The SCALE code system developed at Oak Ridge National Laboratory includes state-of-the-art capabilities for radiation source term and radiation transport simulations that can be used in numerous applications, including dose rate analyses of complex consolidated interim storage facilities (CISFs). A licensed CISF could be used to store tens of thousands of tonnes of spent nuclear fuel discharged from commercial power reactors using various cask and storage pad designs. A CISF design must comply with the regulatory requirements provided in 10 CFR Part 72, including requirements related to annual dose limits applicable to real individuals located beyond the area controlled by the licensee. Therefore, calculating a dose to the public is a necessary part of the licensing process for the construction of a CISF. These calculations are very challenging because of the complexity of the CISF design and the low magnitude of dose rate at large distances from the facility. This paper describes detailed far-field dose rate calculations performed for a proposed CISF using MAVRIC, the Monte Carlo radiation shielding sequence in SCALE 6.2.3, with automated variance reduction based on discrete ordinates calculations. The method presented in this paper uses a detailed Monte Carlo radiation transport simulation in one step from source to dose rate. A series of independent simulations was made using the complete site geometry (all casks present), but with only one cask containing radiation sources to obtain the dose rate maps produced by each storage cask. The CISF dose rate map was obtained by adding the dose rate maps produced by the independent individual cask simulations. Ample volumes of air and soil extending beyond the location of interest for dose rate calculation were included in the calculation model to properly simulate important radiation attenuation and scattering events that affect far-field dose rates. Furthermore, a comprehensive sensitivity study is included in this paper to illustrate the importance of selecting appropriate air volume, mass density, and composition for CISF skyshine dose rate calculations. Dry soil and soil containing water were analyzed to determine their effects on groundshine radiation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-18C-09: Assessment of OSL Dosimeter Technology in the Validation of a Monte Carlo Radiation Transport Code for CT Dosimetry

Purpose: To assess the utility of optically stimulated luminescent (OSL) dosimeter technology in calibrating and validating a Monte Carlo radiation transport code for computed tomography (CT). Methods: Exposure data were taken using both a standard CT 100-mm pencil ionization chamber and a series of 150-mm OSL CT dosimeters. Measurements were made at system isocenter in air as well as in standard 16-cm (head) and 32-cm (body) CTDI phantoms at isocenter and at the 12 o'clock positions. Scans were performed on a Philips Brilliance 64 CT scanner for 100 and 120 kVp at 300 mAs with a nominal beam width of 40 mm. A radiation transport code to simulate the CT scanner conditions was developed using the GEANT4 physics toolkit. The imaging geometry and associated parameters were simulated for each ionization chamber and phantom combination. Simulated absorbed doses were compared to both CTDI{sub 100} values determined from the ion chamber and to CTDI{sub 100} values reported from the OSLs. The dose profiles from each simulation were also compared to the physical OSL dose profiles. Results: CTDI{sub 100} values reported by the ion chamber and OSLs are generally in good agreement (average percent difference of 9%), and provide a suitable way to calibrate doses obtained from simulation to real absorbed doses. Simulated and real CTDI{sub 100} values agree to within 10% or less, and the simulated dose profiles also predict the physical profiles reported by the OSLs. Conclusion: Ionization chambers are generally considered the standard for absolute dose measurements. However, OSL dosimeters may also serve as a useful tool with the significant benefit of also assessing the radiation dose profile. This may offer an advantage to those developing simulations for assessing radiation dosimetry such as verification of spatial dose distribution and beam width.

61 RADIATION PROTECTION AND DOSIMETRY↗

Benchmark Analysis of Pion Contribution from Galactic Cosmic Rays

Shielding strategies for extended stays in space must include a comprehensive resolution of the secondary radiation environment inside the spacecraft induced by the primary, external radiation. The distribution of absorbed dose and dose equivalent is a function of the type, energy and population of these secondary products. A systematic verification and validation effort is underway for HZETRN, which is a space radiation transport code currently used by NASA. It performs neutron, proton and heavy ion transport explicitly, but it does not take into account the production and transport of mesons, photons and leptons. The question naturally arises as to what is the contribution of these particles to space radiation. The pion has a production kinetic energy threshold of about 280 MeV. The Galactic cosmic ray (GCR) spectra, coincidentally, reaches flux maxima in the hundreds of MeV range, corresponding to the pion production threshold. We present results from the Monte Carlo code MCNPX, showing the effect of lepton and meson physics when produced and transported explicitly in a GCR environment.

Aghara, Sukesh K.↗

3D Visualization of Monte-Carlo Simulation's of HZE Track Structure and Initial Chemical Species

Heavy ions biophysics is important for space radiation risk assessment [1] and hadron-therapy [2]. The characteristic of heavy ions tracks include a very high energy deposition region close to the track (<20 nm) denoted as the track core, and an outer penumbra region consisting of individual secondary electrons (6-rays). A still open question is the radiobiological effects of 6- rays relative to the track core. Of importance is the induction of double-strand breaks (DSB) [3] and oxidative damage to the biomolecules and the tissue matrix, considered the most important lesions for acute and long term effects of radiation. In this work, we have simulated a 56Fe26+ ion track of 1 GeV/amu with our Monte-Carlo code RITRACKS [4]. The simulation results have been used to calculate the energy depiction and initial chemical species in a "voxelized" space, which is then visualized in 3D. Several voxels with dose >1000 Gy are found in the penumbra, some located ~0.1 mm from the track core. In computational models, the DSB induction probability is calculated with radial dose [6], which may not take into account the higher RBE of electron track ends for DSB induction. Therefore, these simulations should help improve models of DSB induction and our understanding of heavy ions biophysics.

Plante, Ianik↗

SU-F-J-174: A Series of Computational Human Phantoms in DICOM-RT Format for Normal Tissue Dose Reconstruction in Epidemiological Studies

Purpose: Epidemiological studies of second cancer risk in radiotherapy patients often require individualized dose estimates of normal tissues. Prior to 3D conformal radiation therapy planning, patient anatomy information was mostly limited to 2D radiological images or not even available. Generic patient CT images are often used in commercial radiotherapy treatment planning system (TPS) to reconstruct normal tissue doses. The objective of the current work was to develop a series of reference size computational human phantoms in DICOM-RT format for direct use in dose reconstruction in TPS. Methods: Contours of 93 organs and tissues were extracted from a series of pediatric and adult hybrid computational human phantoms (newborn, 1-, 5-, 10-, 15-year-old, and adult males and females) using Rhinoceros software. A MATLAB script was created to convert the contours into the DICOM-RT structure format. The simulated CT images with the resolution of 1×1×3 mm3 were also generated from the binary phantom format and coupled with the DICOM-structure files. Accurate volumes of the organs were drawn in the format using precise delineation of the contours in converted format. Due to complex geometry of organs, higher resolution (1×1×1 mm3) was found to be more efficient in the conversion of newborn and 1-year-old phantoms. Results: Contour sets were efficiently converted into DICOM-RT structures in relatively short time (about 30 minutes for each phantom). A good agreement was observed in the volumes between the original phantoms and the converted contours for large organs (NRMSD<1.0%) and small organs (NRMSD<7.7%). Conclusion: A comprehensive series of computational human phantoms in DICOM-RT format was created to support epidemiological studies of second cancer risks in radiotherapy patients. We confirmed the DICOM-RT phantoms were successfully imported into the TPS programs of major vendors.

60 APPLIED LIFE SCIENCES↗

4D cone beam CT via spatiotemporal tensor framelet

Purpose: On-board 4D cone beam CT (4DCBCT) offers respiratory phase-resolved volumetric imaging, and improves the accuracy of target localization in image guided radiation therapy. However, the clinical utility of this technique has been greatly impeded by its degraded image quality, prolonged imaging time, and increased imaging dose. The purpose of this letter is to develop a novel iterative 4DCBCT reconstruction method for improved image quality, increased imaging speed, and reduced imaging dose. Methods: The essence of this work is to introduce the spatiotemporal tensor framelet (STF), a high-dimensional tensor generalization of the 1D framelet for 4DCBCT, to effectively take into account of highly correlated and redundant features of the patient anatomy during respiration, in a multilevel fashion with multibasis sparsifying transform. The STF-based algorithm is implemented on a GPU platform for improved computational efficiency. To evaluate the method, 4DCBCT full-fan scans were acquired within 30 s, with a gantry rotation of 200°; STF is also compared with a state-of-art reconstruction method via spatiotemporal total variation regularization. Results: Both the simulation and experimental results demonstrate that STF-based reconstruction achieved superior image quality. The reconstruction of 20 respiratory phases took less than 10 min on an NVIDIA Tesla C2070 GPU card. The STF codes are available at https://sites.google.com/site/spatiotemporaltensorframelet . Conclusions: By effectively utilizing the spatiotemporal coherence of the patient anatomy among different respiratory phases in a multilevel fashion with multibasis sparsifying transform, the proposed STF method potentially enables fast and low-dose 4DCBCT with improved image quality.

60 APPLIED LIFE SCIENCES↗

Study of the distribution profile of iron ions implanted into silicon

Iron ions with energies of 90 and 250 keV and a dose of 10{sup 16} cm{sup –2} are implanted into a silicon single crystal with the (110) orientation. The method of Rutherford backscattering in combination with channeling is used to study the distribution profiles of the introduced impurity and also the profiles of the distribution of radiation-induced defects in the crystal lattice. Experimental data are compared with the results of simulation performed using the TRIM software package. It is shown that, at an energy of 4.6 keV/nucleon, the average projected ranges coincide; however, at an energy of 1.6 keV/nucleon, the difference amounts to 35%. In addition, it is shown that the calculation incorrectly takes into account the dose dependence at energies of 1.6–4.6 keV/nucleon.

36 MATERIALS SCIENCE↗