Search NASA⌕ Search

SEARCH · Search NASA

Results for “Failures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Investigation of Failure Modes, Mechanisms and Driving Forces for Electrically Conductive Adhesives as Interconnects in PV Modules

In this work we describe our current progress into investigating the reliability of ECA interconnects for PV modules. Preliminary thermal cycling experiments demonstrated that both cohesive and adhesive failure of the ECA joint are relevant failure modes that result in an increase of the joints electrical resistance. A thorough viscoelastic characterization of the candidate ECA was conducted to enable accurate numerical modeling of the joint’s response to thermal cycling. Combined with critical and subcritical fracture measurements, the numerical model elucidates that an additional fatigue mechanism exists which can result in fracture well below subcritical debonding threshold values. It is also demonstrated that fracture of the ECA is more sensitive to humidity than temperature and subcritical debonding mechanisms do exist which are again more sensitive to humidity.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Failure Stress and Apparent Elastic Modulus of Diesel Particulate Filter Ceramics

Three established mechanical test specimen geometries and test methods used to evaluate mechanical properties of brittle materials are adapted to the diesel particulate filter (DPF) architecture to evaluate failure initiation stress and apparent elastic modulus of the ceramics comprising DPFs. The three custom-designed test coupons are harvested out of DPFs to promote a particular combination of orientation of crack initiation and crack plane. The testing of the DPF biaxial flexure disk produces a radial tensile stress and a crack plane parallel with the DPF's longitudinal axis. The testing of the DPF sectored flexural specimen produces axial tension at the DPF's OD and a crack plane perpendicular to the DPF's longitudinal axis. The testing of the DPF o-ring specimen produces hoop tension at the DPF's original outer diameter (OD) and at the inner diameter of the test coupon, and a crack plane parallel to the DPF's longitudinal axis. The testing of these mechanical test coupons also enables the determination of an apparent elastic modulus of the DPF ceramic material. Results consistently show that the apparent elastic modulus of the DPF ceramics is much less (e.g., up to an order of magnitude less) than apparent elastic modulus estimated using sonic- or resonance-based test methods. These specimen geometries, produced stress states, and modes of consequential crack initiation are discussed in context to the DPF's symmetry along with the assessments of each specimen's ease of fabrication, testing, failure stress determination, ultimate viability, and prospects for test standardization. Lastly, an explanation is offered for why the apparent elastic modulus measured with these three mechanical test coupons is relatively low and why their low values are more accurate for predicting thermomechanical stresses in DPFs.

36 MATERIALS SCIENCE↗

Investigating lab-scaled offshore wind aerodynamic testing failure and developing solutions for early anomaly detections

As offshore wind systems become more complex, the risk of human error or equipment malfunction increases during experimental testing. This study investigates a lab-scale incident involving a 1 : 50 scale 5 MW wind turbine, where a generator failure led to rotor overspeed and a blade–tower strike. To improve early fault detection, we propose a data-driven method based on multivariate long short-term memory (LSTM) models. High-frequency measurements are projected onto principal components, and anomalies are identified using reconstruction error and its time derivative. Two models are trained on different healthy datasets and tested using single- and multi-principal component (1PC and MPC) variations. Results show that combining both error and error derivative improves detection accuracy. The 1PC model detects faults faster, has a higher recall rate, and achieves a 43 % improvement in anomaly detection accuracy, while the MPC model yields higher precision. This approach provides a simple and effective tool for early anomaly detection in lab-scale experiments, helping to reduce the risk of future failures during the testing of new technologies.

17 WIND ENERGY↗

DMTN-260: Failure Modes and Error Handling for Prompt Processing

The Prompt Processing system will be responsible for processing roughly a thousand visits per night, and distributing the results in near real time, for at least ten years of Rubin Observatory operations. As such, it must be highly robust to algorithmic, network, and infrastructure failures, ranging from momentary glitches to extended downtimes. DMTN-219 introduced the initial design for the Prompt Processing framework; this document expands on the design to address expected failure modes and recovery strategies for each.

79 ASTRONOMY AND ASTROPHYSICS↗

Program computes single-point failures in critical system designs

Computer program analyzes the designs of critical systems that will either prove the design is free of single-point failures or detect each member of the population of single-point failures inherent in a system design. This program should find application in the checkout of redundant circuits and digital systems.

Brown, W. R.↗

Automatic patient respiration failure detection system with wireless transmission

Automatic respiration failure detection system detects respiration failure in patients with a surgically implanted tracheostomy tube, and actuates an audible and/or visual alarm. The system incorporates a miniature radio transmitter so that the patient is unencumbered by wires yet can be monitored from a remote location.

Dimeff, J.↗

Tensile failure of fiber composites.

Composite tensile-failure modes, discussing failure load prediction, experimental data and statistical analysis of stress concentration effects

Zweben, C.↗

Failure in glass

Review of state of the art concerning glass failure mechanisms and fatigue theories discusses brittle fracture in glass, fatigue mechanisms, fatigue behavior, environmental effects on failure rate, and aging.

Keeton, S. C.↗

Analytical failure determination of flow-induced fatigue in bellows

Fatigue failure of bellows when subjected to passage of fluids at high speeds is discussed. It is assumed that flow through bellows generates sound in fluid and vibration caused by sound waves is principal contributor to failure. Effects of sound waves on bellows structure are analyzed.

Cron, R. G.↗

Metallization failures

Metallization-related failure mechanisms were shown to be a major cause of integrated circuit failures under accelerated stress conditions, as well as in actual use under field operation. The integrated circuit industry is aware of the problem and is attempting to solve it in one of two ways: (1) better understanding of the aluminum system, which is the most widely used metallization material for silicon integrated circuits both as a single level and multilevel metallization, or (2) evaluating alternative metal systems. Aluminum metallization offers many advantages, but also has limitations particularly at elevated temperatures and high current densities. As an alternative, multilayer systems of the general form, silicon device-metal-inorganic insulator-metal, are being considered to produce large scale integrated arrays. The merits and restrictions of metallization systems in current usage and systems under development are defined.

Beatty, R.↗

The kinetic and mechanical aspects of hydrogen-induced failure in metals

Premature hydrogen-induced failure observed to occur in many metal systems involves three stages of fracture: (1) crack initiation, (2) stable slow crack growth, and (3) unstable rapid crack growth. The presence of hydrogen at some critical location on the metal surface or within the metal lattice was shown to influence one or both of the first two stages of brittle fracture but has a negligible effect on the unstable rapid crack growth stage. The relative influence of the applied parameters of time, temperature, etc., on the propensity of a metal to exhibit hydrogen induced premature failure was investigated.

Nelson, H. G.↗

Development of KSC program for investigating and generating field failure rates. Reliability handbook for ground support equipment

Field failure rates and confidence factors are presented for 88 identifiable components of the ground support equipment at the John F. Kennedy Space Center. For most of these, supplementary information regarding failure mode and cause is tabulated. Complete reliability assessments are included for three systems, eight subsystems, and nine generic piece-part classifications. Procedures for updating or augmenting the reliability results are also included.

Bloomquist, C. E.↗

Gyro and accelerometer failure detection and identification in redundant sensor systems

Algorithms for failure detection and identification for redundant noncolinear arrays of single degree of freedom gyros and accelerometers are described. These algorithms are optimum in the sense that detection occurs as soon as it is no longer possible to account for the instrument outputs as the outputs of good instruments operating within their noise tolerances, and identification occurs as soon as it is true that only a particular instrument failure could account for the actual instrument outputs within the noise tolerance of good instruments. An estimation algorithm is described which minimizes the maximum possible estimation error magnitude for the given set of instrument outputs. Monte Carlo simulation results are presented for the application of the algorithms to an inertial reference unit consisting of six gyros and six accelerometers in two alternate configurations.

Potter, J. E.↗

Gyro and accelerometer failure detection and identification in redundant sensor systems.

An algorithm for failure detection and identification for redundant non-orthogonal arrays of single degree of freedom gyros and accelerometers is described which is optimum in the sense that detection occurs as soon as it is no longer possible to account for the instrument outputs as the outputs of good instruments operating within their noise tolerances, and identification occurs as soon as it is true that only a particular instrument failure could account for the actual instrument outputs within the noise tolerance of good instruments. An estimation algorithm is described which minimizes the maximum possible error magnitude for the given set of instrument outputs. Monte Carlo simulation results are presented for the application of the algorithms to an inertial reference unit consisting of six gyros and six accelerometers in two alternate configurations.

Potter, J. E.↗

Basic failure mechanisms in advanced composites

Failure mechanisms in carbon-epoxy composites are identified as a basis for more reliable prediction of the performance of these materials. The approach involves both the study of local fracture events in model specimens containing small groups of filaments and fractographic examination of high fiber content engineering composites. Emphasis is placed on the correlation of model specimen observations with gross fracture modes. The effects of fiber surface treatment, resin modification and fiber content are studied and acoustic emission methods are applied. Some effort is devoted to analysis of the failure process in composite/metal specimens.

Mullin, J. V.↗