Search NASA⌕ Search

SEARCH · Search NASA

Results for “High spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Patterned graphene functionalization via mask-free scanning of micro-plasma jet under ambient condition

In this work, a mask-free method is introduced for patterned nitrogen doping of graphene using a micro-plasma jet under ambient condition. Raman and X-ray photoelectron spectroscopy spectra indicate that nitrogen atoms are incorporated into the graphene lattice with the two-dimensional spatial distribution precisely controlled in the range of mm down to 10 μm. Since the chemistry of the micro-plasma jet can be controlled by the choice of the gas mixture, this direct writing process with micro-plasma jet can be a versatile approach for patterned functionalization of graphene with high spatial resolution. This could have promising applications in graphene-based electronics.

36 MATERIALS SCIENCE↗

Detection of a 2.8 THz quantum cascade laser with a semiconductor nanowire field-effect transistor coupled to a bow-tie antenna

The use of a high-electron mobility semiconductor nanowire as transistor channel has recently allowed the extension of the spectral coverage of THz field-effect transistor detectors up to 1.5 THz. In this report, we demonstrate efficient operation of a field-effect transistor detector based on a semiconductor nanowire at a much higher frequency, 2.8 THz, with a responsivity ≈5 V/W in a bandwidth ≈100 kHz, thus proving the full potential of such approach for the detection of THz quantum cascade lasers. Finally, such a THz sensing system is exploited to perform raster scan transmission imaging, with high spatial resolution, signal-to-noise ratio, and acquisition rate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Indus-2 X-ray lithography beamline for X-ray optics and material science applications

X-ray lithography is an ideal technique by which high aspect ratio and high spatial resolution micro/nano structures are fabricated using X-rays from synchrotron radiation source. The technique has been used for fabricating optics (X-ray, visible and infrared), sensors and actuators, fluidics and photonics. A beamline for X-ray lithography is operational on Indus-2. The beamline offers wide lithographic window from 1-40keV photon energy and wide beam for producing microstructures in polymers upto size ∼100mm × 100mm. X-ray exposures are possible in air, vacuum and He gas environment. The air based exposures enables the X-ray irradiation of resist for lithography and also irradiation of biological and liquid samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Movable multi-probes for plasma boundary measurement in sino-united spherical tokamak

A novel movable multi-probes is developed to get local magnetic and electrostatic profiles on Sino-UNIted Spherical Tokamak (SUNIST). This multi-probes combines a four-tips Langmuir probe, a magnetic coil, and a retarding field energy analyzer (RFEA). It can be used to simultaneously measure the poloidal magnetic field B{sub p}, electric field E{sub r}, electron temperature T{sub e}, electron density n{sub e}, and ion temperature T{sub i}. Its small overall size (20 × 20 × 38 mm{sup 3}) enables the movable multi-probes to measure the magnetic and electrostatic profiles in high spatial resolution, with negligible impact to plasma in SUNIST. This paper presents the design of the movable multi-probes, in particular, details of RFEA for reliable ion energy measurements. Preliminary experimental results of the movable multi-probes are given as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single photon emission at 1.55 μm from charged and neutral exciton confined in a single quantum dash

We investigate charged and neutral exciton complexes confined in a single self-assembled InAs/InGaAlAs/InP quantum dash emitting at 1.55 μm. The emission characteristics have been probed by measuring high-spatial-resolution polarization-resolved photoluminescence and cross-correlations of photon emission statistics at T = 5 K. The photon auto-correlation histogram of the emission from both the neutral and charged exciton indicates a clear antibunching dip with as-measured g{sup (2)}(0) values of 0.18 and 0.31, respectively. It proves that these exciton complexes confined in single quantum dashes of InP-based material system can act as true single photon emitters being compatible with standard long-distance fiber communication technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accurate measurement of relative tilt and azimuth angles in electron tomography: A comparison of fiducial marker method with electron diffraction

Electron tomography is a method whereby a three-dimensional reconstruction of a nanoscale object is obtained from a series of projected images measured in a transmission electron microscope. We developed an electron-diffraction method to measure the tilt and azimuth angles, with Kikuchi lines used to align a series of diffraction patterns obtained with each image of the tilt series. Since it is based on electron diffraction, the method is not affected by sample drift and is not sensitive to sample thickness, whereas tilt angle measurement and alignment using fiducial-marker methods are affected by both sample drift and thickness. The accuracy of the diffraction method benefits reconstructions with a large number of voxels, where both high spatial resolution and a large field of view are desired. The diffraction method allows both the tilt and azimuth angle to be measured, while fiducial marker methods typically treat the tilt and azimuth angle as an unknown parameter. The diffraction method can be also used to estimate the accuracy of the fiducial marker method, and the sample-stage accuracy. A nano-dot fiducial marker measurement differs from a diffraction measurement by no more than ±1°.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting vapour bubbles in simulations of metastable water

The investigation of cavitation in metastable liquids with molecular simulations requires an appropriate definition of the volume of the vapour bubble forming within the metastable liquid phase. Commonly used approaches for bubble detection exhibit two significant flaws: first, when applied to water they often identify the voids within the hydrogen bond network as bubbles thus masking the signature of emerging bubbles and, second, they lack thermodynamic consistency. Here, we present two grid-based methods, the M-method and the V-method, to detect bubbles in metastable water specifically designed to address these shortcomings. The M-method incorporates information about neighbouring grid cells to distinguish between liquid- and vapour-like cells, which allows for a very sensitive detection of small bubbles and high spatial resolution of the detected bubbles. The V-method is calibrated such that its estimates for the bubble volume correspond to the average change in system volume and are thus thermodynamically consistent. Both methods are computationally inexpensive such that they can be used in molecular dynamics and Monte Carlo simulations of cavitation. We illustrate them by computing the free energy barrier and the size of the critical bubble for cavitation in water at negative pressure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Implosion dynamics measurements by monochromatic x-ray radiography in inertial confinement fusion

The implosion dynamics is the most important metrics for assessing the progress toward ignition of an inertially confined fusion experiment. A high spatial resolution monochromatic x-ray imaging system based on the spherically bent crystal is developed to measure the implosion trajectory. The density distribution of the imploding capsules can be inferred with more accurately from monochromatic trajectories. The self emission of the imploded core will be restrained by spectral resolution and the setup of the imaging system. Also the variations of the backlighters' intensity will not be seen in the images. It has been demonstrated on SGII laser facility at the first time. The ablator remaining mass and the implosion velocity, which are the important ablator parameters, are calculated from the monochromatic trajectories. And the results are contrasted to the 1D hydrodynamics simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Confocal shift interferometry of coherent emission from trapped dipolar excitons

We introduce a confocal shift-interferometer based on optical fibers. The presented spectroscopy allows measuring coherence maps of luminescent samples with a high spatial resolution even at cryogenic temperatures. We apply the spectroscopy onto electrostatically trapped, dipolar excitons in a semiconductor double quantum well. We find that the measured spatial coherence length of the excitonic emission coincides with the point spread function of the confocal setup. The results are consistent with a temporal coherence of the excitonic emission down to temperatures of 250 mK.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wetting state on hydrophilic and hydrophobic micro-textured surfaces: Thermodynamic analysis and X-ray visualization

In this study, the wetting state on hydrophobic and hydrophilic micro-textured surfaces was investigated. High spatial resolution synchrotron X-ray radiography was used to overcome the limitations in visualization in previous research and clearly visualize the wetting state for each droplet under quantified surface conditions. Based on thermodynamic characteristics, a theoretical model for wetting state depending on the chemical composition (intrinsic contact angle) and geometrical morphology (roughness ratio) of the surfaces was developed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Near-isothermal furnace for in situ and real time X-ray radiography solidification experiments

In this paper, we present a newly developed near-isothermal X-ray transparent furnace for in situ imaging of solidification processes in thin metallic samples. We show that the furnace is ideally suited to study equiaxed microstructure evolution and grain interaction. To observe the growth dynamics of equiaxed dendritic structures, a minimal temperature gradient across the sample is required. A uniform thermal profile inside a circular sample is achieved by positioning the sample in the center of a cylindrical furnace body surrounded by a circular heater arrangement. Performance tests with the hypo-eutectic Al-15wt.%Cu and the near-eutectic Al-33wt.%Cu alloys validate the near-isothermal character of the sample environment. Controlled cooling rates of less than 0.5 K min{sup −1} up to 10 K min{sup −1} can be achieved in a temperature range of 720 K–1220 K. Integrated in our rotatable laboratory X-ray facility, X-RISE, the furnace provides a large field of view of 10.5 mm in diameter and a high spatial resolution of ∼4 μm. With the here presented furnace, equiaxed dendrite growth models can be rigorously tested against experiments on metal alloys by, e.g., enabling dendrite growth velocities to be determined as a function of undercooling or solutal fields in front of the growing dendrite to be measured.

36 MATERIALS SCIENCE↗

Two dimensional numerical simulations of carrier dynamics during time-resolved photoluminescence decays in two-photon microscopy measurements in semiconductors

We use two-dimensional numerical simulations to analyze high spatial resolution time-resolved spectroscopy data. This analysis is applied to two-photon excitation time-resolved photoluminescence (2PE-TRPL) but is broadly applicable to all microscopic time-resolved techniques. By solving time-dependent drift-diffusion equations, we gain insight into carrier dynamics and transport characteristics. Accurate understanding of measurement results establishes the limits and potential of the measurement and enhances its value as a characterization method. Diffusion of carriers outside of the collection volume can have a significant impact on the measured decay but can also provide an estimate of carrier mobility as well as lifetime. In addition to material parameters, the experimental conditions, such as spot size and injection level, can impact the measurement results. Although small spot size provides better resolution, it also increases the impact of diffusion on the decay; if the spot size is much smaller than the diffusion length, it impacts the entire decay. By reproducing experimental 2PE-TRPL decays, the simulations determine the bulk carrier lifetime from the data. The analysis is applied to single-crystal and heteroepitaxial CdTe, material important for solar cells, but it is also applicable to other semiconductors where carrier diffusion from the excitation volume could affect experimental measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electric field stimulation setup for photoemission electron microscopes

Manipulating magnetisation by the application of an electric field in magnetoelectric multiferroics represents a timely issue due to the potential applications in low power electronics and the novel physics involved. Thanks to its element sensitivity and high spatial resolution, X-ray photoemission electron microscopy is a uniquely suited technique for the investigation of magnetoelectric coupling in multiferroic materials. In this work, we present a setup that allows for the application of in situ electric and magnetic fields while the sample is analysed in the microscope. As an example of the performances of the setup, we present measurements on Ni/Pb(Mg{sub 0.66}Nb{sub 0.33})O{sub 3}-PbTiO{sub 3} and La{sub 0.7}Sr{sub 0.3}MnO{sub 3}/PMN-PT artificial multiferroic nanostructures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy-loss magnetic chiral dichroism study of epitaxial MnAs film on GaAs(001)

The room-temperature ferromagnetic behavior of MnAs/GaAs(001) thin film has been locally explored by Transmission Electron Microscope (TEM). We first differentiated hexagonal α-MnAs and quasi-hexagonal β-MnAs which are very similar in atomic structure by electron diffraction. Local magnetic moment information of the identified α-MnAs was extracted from manganese-L{sub 2,3} edges using Energy-loss Magnetic Circular Dichroism technique and the ratio of orbital to spin magnetic moment was measured. In this experiment, atomic structure identification, chemical analysis, and magnetic moment measurement were simultaneously achieved at high spatial resolution in TEM, thus providing a potential method for in-situ study of local properties of multiphase magnetic materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The spectral imaging facility: Setup characterization

The SPectral IMager (SPIM) facility is a laboratory visible infrared spectrometer developed to support space borne observations of rocky bodies of the solar system. Currently, this laboratory setup is used to support the DAWN mission, which is in its journey towards the asteroid 1-Ceres, and to support the 2018 Exo-Mars mission in the spectral investigation of the Martian subsurface. The main part of this setup is an imaging spectrometer that is a spare of the DAWN visible infrared spectrometer. The spectrometer has been assembled and calibrated at Selex ES and then installed in the facility developed at the INAF-IAPS laboratory in Rome. The goal of SPIM is to collect data to build spectral libraries for the interpretation of the space borne and in situ hyperspectral measurements of planetary materials. Given its very high spatial resolution combined with the imaging capability, this instrument can also help in the detailed study of minerals and rocks. In this paper, the instrument setup is first described, and then a series of test measurements, aimed to the characterization of the main subsystems, are reported. In particular, laboratory tests have been performed concerning (i) the radiation sources, (ii) the reference targets, and (iii) linearity of detector response; the instrumental imaging artifacts have also been investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of toroidal vessel eddy current during plasma disruption on J-TEXT

In this paper, we have employed a thin, printed circuit board eddy current array in order to determine the radial distribution of the azimuthal component of the eddy current density at the surface of a steel plate. The eddy current in the steel plate can be calculated by analytical methods under the simplifying assumptions that the steel plate is infinitely large and the exciting current is of uniform distribution. The measurement on the steel plate shows that this method has high spatial resolution. Then, we extended this methodology to a toroidal geometry with the objective of determining the poloidal distribution of the toroidal component of the eddy current density associated with plasma disruption in a fusion reactor called J-TEXT. The preliminary measured result is consistent with the analysis and calculation results on the J-TEXT vacuum vessel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The structure of a magnetic-field front propagating non-diffusively in low-resistivity multi-species plasma

We report on the first experimental verification of the traveling-wave-like picture of a magnetic-field and an associated electric potential hill propagating non-diffusively in low resistivity plasma. High spatial resolution spectroscopic method, developed here, allowed for obtaining the detailed shape of the propagating magnetic-field front. The measurements demonstrated that the ion separation, previously claimed, results from the reflection of the higher charge-to-mass ratio ions from the propagating potential hill and from climbing the hill by the lower charge-to-mass ratio ions. This ion dynamics is found to be consistent with the observed electron density evolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Near-field scanning magneto-optical spectroscopy of Wigner molecules

We study the emission spectra of single self-organized InP/GaInP QDs (size 100-220 nm) using high-spatial-resolution, low-temperature (5 K) near-field scanning optical microscope (NSOM) operating at magnetic field strength B=0-10 T. The dots contain up to twenty electrons and represent natural Wigner molecules (WM). We observed vibronic-type shake-up structure in single electron QDs manifesting formation of two electron (2e) WM in photo-excited state. We found that relative intensities of the shake-up components described well by vibronic Frank-Condon factors giving for dots having parabolic confinement energy ħω{sub 0}=1.2-4 meV molecule bond lengths 40-140 nm. We used measurements of magnetic-field-induced shifts to distinguish emission of 2e-WM and singly charged exciton (trion). We also observed magnetic-field-induced molecular-droplet transition for two electron dot, emitting through doubly charge exciton (tetron) at zero magnetic field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗