Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Vacancy effects on the formation of helium and krypton cavities in 3-C-SiC irradiated and annealed at elevated temperatures

Polycrystalline 3C-SiC was sequentially irradiated at 400 and 750°C with 120 keV He 2+ and 4 MeV Kr 15+ ions to 10 17 and 41016 cm -2 , respectively. The Kr 15+ ions penetrated the entire depth of the He 2+ ion implantation region. Three areas of He 2+ , Kr 15+ and He 2+ + Kr 15+ ion implanted 3C-SiC were created through masked overlapping irradiations. The sample was subsequently annealed at 1600°C in vacuum and characterized using cross-sectional transmission electron microscopy and energy-dispersive x-ray spectroscopy. Compared to the He 2+ ion only implanted 3C-SiC, helium cavities in the He 2+ and Kr15+ co-implanted 3C-SiC had a smaller size but higher density. At 25 dpa, presence of He in the co-implanted 3C-SiC significantly promoted cavity growth; much smaller voids were formed in the Kr 15+ ion only irradiated 3C-SiC at the same dose. In addition, local Kr migration and trapping at cavities occurred, but long-range Kr diffusion in 3C-SiC was not observed up to 1600°C.

36 MATERIALS SCIENCE↗

Laboratory Monitoring of Bone Tissue Remodeling after Augmentation of Impression Intraarticular Fracture with Different Types of Bone Graft

The effects of bone graft materials on the inflammatory response and biochemical markers of bone remodeling were studied on a rabbit model of fracture augmentation with the following grafts: β-tricalcium phosphate, demineralized bone matrix, nanostructured carbon implant, and porous titanium implant made by additive 3D printing. The markers of bone remodeling and the blood system response in the postoperative period were studied. It was found that porous titanium implant and β-tricalcium phosphate induced osteogenesis and minimized osteoclastic resorption. Augmentation with nanostructured carbon implant and demineralized bone matrix stimulated the processes of osteoclastic resorption.

3D PRINTING↗

Microstructure of titanium on complex deformation paths: Comparison of ECAP, KOBO and HE techniques

Highlights: • Method for producing CP titanium rods for medical implants is searched. • Three processing methods producing ultra-fine grain titanium are compared. • Microstructure and textures are examined and analysed. • Mechanical characteristics are determined based on microhardness and tensile tests. • Hydrostatic extrusion (HE) leads to the best properties of titanium rods for medical implants. - Abstract: In this work samples of commercial purity grade 2 titanium were severely deformed by three different extrusion techniques: equal-channel angular pressing (ECAP), extrusion through oscillating die (KOBO), and hydrostatic extrusion (HE). Resulting microstructures and mechanical properties of processed titanium samples are studied and compared with regard to potential application as a material for dental implants. The obtained results demonstrate the effect of different strain paths, involved by three applied deformation methods, on microstructure refinement, mechanical properties and textures of the studied material. Heterogeneous microstructures with bimodal grain size distributions are observed for all deformation techniques in the examined material, however differences in their internal structures and grain boundary distributions point to different grain refinement mechanisms. The fraction of ultra-fine grains is the highest in titanium deformed by HE. Also the internal grain fragmentation is the most important after HE deformation. This leads to the best mechanical and microstructural properties obtained in this type of deformation. Consequently, the HE process seems to be very interesting for production of material for medical implants.

36 MATERIALS SCIENCE↗

Influence of substrate composition on size and chemical state of ion beam synthesised Co nanoparticles – Towards fabrication of electrodes for energy devices

A one-step approach to synthesize ultrafine transition metal particles (size < 5 nm) in carbon substrates is highly desirable for fabricating electrodes for energy devices. Herein, cobalt ion implantation into amorphous carbon films (a:C) and hydrogenated amorphous carbon films (a:CH) was explored, with the aim of synthesizing ultrafine metallic cobalt nanoparticles at room temperature. Co ions of 30 keV energy were implanted into the carbon films to achieve a Co areal density of 1.0 ± 0.1 × 10 17 atoms cm -2 . Rutherford backscattering measurements revealed that hydrogenated amorphous carbon films gave a broader Co depth distribution compared to the amorphous carbon films. Further, cross-sectional TEM analysis revealed that hydrogenated carbon films suppressed metallic Co nanoparticle aggregation, leading to the creation of ultrafine Co nanoparticles (size < 5 nm). Co L-edge X-ray absorption spectroscopy measurements confirmed the formation of predominantly metallic Co nanoparticles by ion implantation. Results conclusively demonstrate that the presence of hydrogen (~ 28 at%) in the carbon matrix facilitates the synthesis of ultrafine metallic Co nanoparticles during Co ion implantation.

36 MATERIALS SCIENCE↗

A preliminary evaluation of immune stimulation following exposure to metal particles and ions using the mouse popliteal lymph node assay

The objective of this preliminary study was to evaluate the threshold for immune stimulation in mice following local exposure to metal particles and ions representative of normal-functioning cobalt-chromium (CoCr) metal-on-metal (MoM) hip implants. The popliteal lymph node assay (PLNA) was used in this study to assess immune responses in BALB/c mice following treatment with chromium-oxide (Cr{sub 2}O{sub 3}) particles, metal salts (CoCl{sub 2}, CrCl{sub 3} and NiCl{sub 2}), or Cr{sub 2}O{sub 3} particles together with metal salts using single-dose exposures representing approximately 10 days (0.000114 mg), 19 years (0.0800 mg), and 40 years (0.171 mg) of normal implant wear. The immune response elicited following treatment with Cr{sub 2}O{sub 3} particles together with metal salts was also assessed at four additional doses equivalent to approximately 1.5 months (0.0005 mg), 0.6 years (0.0025 mg), 2.3 years (0.01 mg), and 9.3 years (0.04 mg) of normal implant wear. Mice were injected subcutaneously (50 μL) into the right hind foot with the test article, or with the relevant vehicle control. The proliferative response of the draining lymph node cells (LNC) was measured four days after treatment, and stimulation indices (SI) were derived relative to vehicle controls. The PLNA was negative (SI < 3) for all Cr{sub 2}O{sub 3} particle doses, and was also negative at the lowest dose of the metal salt mixture, and the lowest four doses of the Cr{sub 2}O{sub 3} particles with metal salt mixture. The PLNA was positive (SI > 3) at the highest two doses of the metal salt mixture and the highest three doses of the Cr{sub 2}O{sub 3} particles with the metal salt mixture. The provisional NOAEL and LOAEL values identified in this study for immune activation corresponds to Co and Cr concentrations in the synovial fluid approximately 500 and 2000 times higher than that reported for normal-functioning MoM hip implants, respectively. Overall, these results indicate that normal wear conditions are unlikely to result in immune stimulation in individuals not previously sensitized to metals. - Highlights: • Immune responses in mice were assessed following treatment with Cr2O3 particles with metal salts. • The PLNA was negative (SI < 3) for all Cr2O3 particle doses. • A LOAEL for immune activation was identified at 0.04 mg of metal particles with metal salts. • A NOAEL for immune activation was identified at 0.01 mg of metal particles with metal salts.

60 APPLIED LIFE SCIENCES↗

Surface Mechanoengineering of a Zr-based Bulk Metallic Glass via Ar-Nanobubble Doping to Probe Cell Sensitivity to Rigid Materials

In this paper, a new materials platform, utilizing the amorphous microstructure of bulk metallic glasses (BMGs) and the versatility of ion implantation, was developed for the fundamental investigation of cell responses to substrate-rigidity variations in the gigapascal modulus range, which was previously unattainable with polymeric materials. The surface rigidity of a Zr-Al- Ni-Cu-Y BMG was modulated with low-energy Ar-ion implantation owing to the impartment of Ar nanobubbles into the amorphous matrix. Surface softening was achieved due to the formation of nanobubble-doped transitional zones in the Zrbased BMG substrate. Bone-forming cell studies on this newly designed platform demonstrated that mechanical cues, accompanied with the potential effects of other surface properties (i.e. roughness, morphology, and chemistry), contributed to modulating cell behaviors. Cell adhesion and actin filaments were found to be less established on less stiff surfaces, especially on the surface with an elastic modulus of 51 GPa. Cell growth appeared to be affected by surface mechanical properties. A lower stiffness was generally related to a higher growth rate. Findings in this study broadened our fundamental understanding concerning the mechanosensing of bone cells on stiff substrates. It also suggests that surface mechano-engineering of metallic materials could be a potential strategy to promote osseointegration of such materials for bone-implant applications. Further investigations are proposed to fine tune the ion implantation variables in order to further distinguish the surface-mechanical effect on bone-forming cell activities from the contributions of other surface properties.

36 MATERIALS SCIENCE↗

Defect mitigation by ion induced amorphousization and solid-phase epitaxy

Ion implantation is a common technique in the semiconductor industry used to modify the electrical properties of materials, usually silicon. Some dopant ions are sufficiently light, such as boron, that they do not create a continuous amorphous layer in silicon over the range of the ions. In the presence of such a layer, most of the ioninduced damage can be removed by solid-phase epitaxy growth (SPEG), which results in recrystallization of the amorphous damage. However, end-of-range defects at the amorphous-crystal interface give rise to threading dislocations during SPEG that degrade the quality of the recrytallized Si. We have studied the end of range defects in silicon with three different implantations. The first was with 80 keV {sup 30}Si with a dose of 3 Multiplication-Sign 10{sup 15} Si/cm{sup 2}, and the second was with 100 keV {sup 72}Ge at a dose of 1 Multiplication-Sign 10{sup 15} Ge/cm{sup 2}, and the third was a double implant of 100 keV {sup 72}Ge at a dose of 1 Multiplication-Sign 10{sup 15} Ge/cm{sup 2} followed by 340 keV {sup 28}Si at a dose of 3 Multiplication-Sign 10{sup 14} Si/cm{sup 2}. SPEG was done at 650 Degree-Sign C to recrystalize the implanted samples, and the end of range defects were studied using channeled Rutherford Backscattering Spectrometry (RBS-c). The effects of photon-assisted hydrogenation on amorphization and recrystallization were also studied.

36 MATERIALS SCIENCE↗

Controlled synthesis of buried delta-layers of Ag nanocrystals for near-field plasmonic effects on free surfaces

We report on the shallow synthesis by low energy ion implantation of delta-layers of Ag nanocrystals in SiO{sub 2} at few nanometers under its free surface. Transmission electron microscopy observations, ballistic simulations, and reflectance measurements are coupled to define the conditions for which the synthesis is fully controlled and when, on the contrary, this control is lost. We show that low dose implantation leads to the formation of a well-defined single plane of nanocrystals, while for larger doses, sputtering and diffusion effects limit the control of the size, position, and volume amount of these nanocrystals. This paper provides the experimental evidence of the incorporated dose saturation predicted in the literature when implanting metal ions at high doses in glass matrices. Its consequences on the particle population and the plasmonic optical response of the composite layers are carefully analyzed. We show here that this saturation phenomenon is underestimated in standard simulation predictions due to diffusion of metal atoms towards the surface and nanocrystal nucleation during the implantation process.

36 MATERIALS SCIENCE↗

Creation of deep blue light emitting nitrogen-vacancy center in nanosized diamond

This paper reports on the formation of complex defect centers related to the N3 center in nanosized diamond by employing plasma immersion and focused ion beam implantation methods. He{sup +} ion implantation into nanosized diamond “layer” was performed with the aim of creating carbon atom vacancies in the diamond structure, followed by the introduction of molecular N{sub 2}{sup +} ion and heat treatment in vacuum at 750 °C to initiate vacancy diffusion. To decrease the sp{sup 2} carbon content of nanosized diamond formed during the implantation processes, a further heat treatment at 450 °C in flowing air atmosphere was used. The modification of the bonding properties after each step of defect creation was monitored by Raman scattering measurements. The fluorescence measurements of implanted and annealed nanosized diamond showed the appearance of an intensive and narrow emission band with fine structures at 2.98 eV, 2.83 eV, and 2.71 eV photon energies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tuning the ferromagnetic-antiferromagnetic interfaces of granular Co-CoO exchange bias systems by annealing

The low-temperature magnetic behavior of granular Co-CoO exchange bias systems, prepared by oxygen ion implantation in Co thin films and subsequent annealing, is addressed. The thermal activation effects lead to an O migration which results in virtually pure Co areas embedded in a structurally relaxed and nearly stoichiometric CoO phase. This yields decreased training and exchange bias shifts, while the blocking temperature significantly increases, coming close to the Néel temperature of bulk CoO for samples implanted to a fluence above 1 × 10{sup 17} ions/cm{sup 2} (15% O). The dependence of the exchange bias shift on the pristine O-implanted content is analogous to that of the antiferromagnetic thickness in most ferromagnetic/antiferromagnetic systems (i.e., an increase in the exchange bias shift up to a maximum followed by a decrease until a steady state is reached), suggesting that, after annealing, the enriched Co areas might be rather similar in size for samples implanted above 1 × 10{sup 17} ions/cm{sup 2}, whereas the corresponding CoO counterparts become enlarged with pristine O content (i.e., effect of the antiferromagnet size). This study demonstrates that the magnetic properties of granular Co-CoO systems can be tailored by controllably modifying the local microstructure through annealing treatments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Atomistic simulation of damage accumulation and amorphization in Ge

Damage accumulation and amorphization mechanisms by means of ion implantation in Ge are studied using Kinetic Monte Carlo and Binary Collision Approximation techniques. Such mechanisms are investigated through different stages of damage accumulation taking place in the implantation process: from point defect generation and cluster formation up to full amorphization of Ge layers. We propose a damage concentration amorphization threshold for Ge of ∼1.3 × 10{sup 22} cm{sup −3} which is independent on the implantation conditions. Recombination energy barriers depending on amorphous pocket sizes are provided. This leads to an explanation of the reported distinct behavior of the damage generated by different ions. We have also observed that the dissolution of clusters plays an important role for relatively high temperatures and fluences. The model is able to explain and predict different damage generation regimes, amount of generated damage, and extension of amorphous layers in Ge for different ions and implantation conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ion beam synthesis of ZrC{sub x}O{sub y} nanoparticles in cubic zirconia

{110}-oriented yttria-stabilized zirconia single crystals have been implanted with low-energy C ions in an axial direction, at room temperature and at 550 °C. Room temperature ion implantation generated a damage layer that contains the expected dislocation loop clusters. Strikingly, the high temperature implantation produced zirconium oxycarbide nanoparticles (ZrC{sub x}O{sub y}) at a shallow depth in the yttria-stabilized cubic zirconia crystal, with a diameter in the range of 4–10 nm. Moreover, in the high concentration region of implanted C ions, between 100 and 150 nm below the surface, a number of large precipitates, up to 20 nm, were observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Helium solubility in SON68 nuclear waste glass

Helium behavior in a sodium borosilicate glass (SON68) dedicated to the immobilization of high-level nuclear waste is examined. Two experimental approaches on nonradioactive glass specimens are implemented: pressurized helium infusion experiments and {sup 3}He ion implantation experiments. The temperature variation of helium solubility in SON68 glass was determined and analyzed with the harmonic oscillator model to determine values of the energy of interaction E(0) at the host sites (about -4000 J/mol), the vibration frequency (about 1.7 x 10{sup 11} s{sup -1}), and the density of solubility sites (2.2 x 10{sup 21} sites cm{sup -3}). The implantation experiments show that a non diffusive transport phenomenon (i.e., athermal diffusion) is involved in the material when the helium concentration exceeds 2.3 x 10{sup 21} He cm{sup -3}, and thus probably as soon as it exceeds the density of solubility sites accessible to helium in the glass. We propose that this transport mechanism could be associated with the relaxation of the stress gradient induced by the implanted helium profile, which is favored by the glass damage. Microstructural characterization by TEM and ESEM of glass specimens implanted with high helium concentrations showed a homogeneous microstructure free of bubbles, pores, or cracking at a scale of 10 nm. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monte Carlo investigation of I-125 interseed attenuation for standard and thinner seeds in prostate brachytherapy with phantom validation using a MOSFET

Purpose: In permanent seed implant prostate brachytherapy the actual dose delivered to the patient may be less than that calculated by TG-43U1 due to interseed attenuation (ISA) and differences between prostate tissue composition and water. In this study the magnitude of the ISA effect is assessed in a phantom and in clinical prostate postimplant cases. Results are compared for seed models 6711 and 9011 with 0.8 and 0.5 mm diameters, respectively. Methods: A polymethyl methacrylate (PMMA) phantom was designed to perform ISA measurements in a simple eight-seed arrangement and at the center of an implant of 36 seeds. Monte Carlo (MC) simulation and experimental measurements using a MOSFET dosimeter were used to measure dose rate and the ISA effect. MC simulations of 15 CT-based postimplant prostate treatment plans were performed to compare the clinical impact of ISA on dose to prostate, urethra, rectum, and the volume enclosed by the 100% isodose, for 6711 and 9011 seed models. Results: In the phantom, ISA reduced the dose rate at the MOSFET position by 8.6%-18.3% (6711) and 7.8%-16.7% (9011) depending on the measurement configuration. MOSFET measured dose rates agreed with MC simulation predictions within the MOSFET measurement uncertainty, which ranged from 5.5% to 7.2% depending on the measurement configuration (k= 1, for the mean of four measurements). For 15 clinical implants, the mean ISA effect for 6711 was to reduce prostate D90 by 4.2 Gy (3%), prostate V100 by 0.5 cc (1.4%), urethra D10 by 11.3 Gy (4.4%), rectal D2cc by 5.5 Gy (4.6%), and the 100% isodose volume by 2.3 cc. For the 9011 seed the mean ISA effect reduced prostate D90 by 2.2 Gy (1.6%), prostate V100 by 0.3 cc (0.7%), urethra D10 by 8.0 Gy (3.2%), rectal D2cc by 3.1 Gy (2.7%), and the 100% isodose volume by 1.2 cc. Differences between the MC simulation and TG-43U1 consensus data for the 6711 seed model had a similar impact, reducing mean prostate D90 by 6 Gy (4.2%) and V100 by 0.6 cc (1.8%). Conclusions: ISA causes the delivered dose in prostate seed implant brachytherapy to be lower than the dose calculated by TG-43U1. MC simulation of phantom seed arrangements show that dose at a point can be reduced by up to 18% and this has been validated using a MOSFET dosimeter. Clinical simulations show that ISA reduces DVH parameter values, but the reduction is less for thinner seeds.

60 APPLIED LIFE SCIENCES↗

SU-E-T-507: Interfractional Variation of Fiducial Marker Position During HDR Brachytherapy with Cervical Interstitial Needle Template

Purpose: HDR brachytherapy using interstitial needle template for cervical cancer is commonly delivered in 4-5 fractions. Routine verification of needle positions before each fraction is often based on radiographic imaging of implanted fiducial markers. The current study evaluated interfractional displacement of implanted fiducial markers using CT images. Methods: 9 sequential patients with cervical interstitial needle implants were evaluated. The superior and inferior borders of the target volumes were defined by fiducial markers in planning CT. The implant position was verified with kV orthogonal images before each fraction. A second CT was acquired prior 3rd fraction (one or 2 days post planning CT). Distances from inferior and superior fiducial markers to pubic symphysis plane (perpendicular to vaginal obtulator)were measured. Distance from needle tip of a reference needle (next to the inferior marker) to the pubic symphysis plane was also determined. The difference in fiducial marker distance or needle tip distance between planning CT and CT prior 3rd fraction were measured to assess markers migration and needle displacement. Results: The mean inferior marker displacement was 4.5 mm and ranged 0.9 to 11.3 mm. The mean superior marker displacement was 2.7 mm and ranged 0 to 10.4 mm. There was a good association between inferior and superior marker displacement (r=0.95). Mean averaged inferior and superior marker displacement was 3.3 mm and ranged from 0.1 to 10.9 mm, with a standard deviation of 3.2 mm. The mean needle displacement was 5.6 mm and ranged 0.2 to 15.6 mm. Needle displacements were reduced (p<0.05) after adjusting according to needle-to-fiducials distance. Conclusion: There were small fiducial marker displacements between HDR fractions. Our study suggests a target margin of 9.7 mm to cover interfractional marker displacements (in 95% cases) for pretreatment verification based on radiographic imaging.

60 APPLIED LIFE SCIENCES↗

Feasibility of vibro-acoustography with a quasi-2D ultrasound array transducer for detection and localizing of permanent prostate brachytherapy seeds: A pilot ex vivo study

Purpose: Effective permanent prostate brachytherapy (PPB) requires precise placement of radioactive seeds in and around the prostate. The impetus for this research is to examine a new ultrasound-based imaging modality, vibro-acoustography (VA), which may serve to provide a high rate of PPB seed detection while also effecting enhanced prostate imaging. The authors investigate the ability of VA, implemented on a clinical ultrasound (US) scanner and equipped with a quasi-2D (Q2D) array US transducer, to detect and localize PPB seeds in excised prostate specimens. Methods: Nonradioactive brachytherapy seeds were implanted into four excised cadaver prostates. A clinical US scanner equipped with a Q2D array US transducer was customized to acquire both US and C-scan VA images at various depths. The VA images were then used to detect and localize the implanted seeds in prostate tissue. To validate the VA results, computed tomography (CT) images of the same tissue samples were obtained to serve as the reference by which to evaluate the performance of VA in PPB seed detection. Results: The results indicate that VA is capable of accurately identifying the presence and distribution of PPB seeds with a high imaging contrast. Moreover, a large ratio of the PPB seeds implanted into prostate tissue samples could be detected through acquired VA images. Using CT-based seed identification as the standard, VA was capable of detecting 74%–92% of the implanted seeds. Additionally, the angular independency of VA in detecting PPB seeds was demonstrated through a well-controlled phantom experiment. Conclusions: Q2DVA detected a substantial portion of the seeds by using a 2D array US transducer in excised prostate tissue specimens. While VA has inherent advantages associated with conventional US imaging, it has the additional advantage of permitting detection of PPB seeds independent of their orientation. These results suggest the potential of VA as a method for PPB imaging that ultimately may allow US-based real-time intraoperative dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-609: Perturbation Effects of Pedicle Screws On Radiotherapy Dose Distributions

Purpose: Radiation therapy in conjunction with surgical implant fixation is a common combined treatment in case of bone metastases. However, metal implants generally used in orthopedic implants perturb radiation dose distributions. Carbon-Fiber Reinforced (CFR) PEEK material has been recently introduced for production of intramedullary screws and plates. Gold powder can be added to the CFR-PEEK material in order to enhance visibility of the screws during intraoperative imaging procedures. In this work, we investigated the perturbation effects of the pedicle screws made of CFR-PEEK, CFR-PEEK with added gold powder (CFR-PEEK-AU) and Titanium (Ti) on radiotherapy dose distributions. Methods: Monte Carlo (MC) simulations were performed using the EGSnrc code package for 6MV beams with 10×10 fields at SSD=100cm. By means of MC simulations, dose distributions around titanium, CFR- PEEK and CFR-PEEK-AU screws (manufactured by Carbo-Fix Orthopedics LTD, Israel) placed in a water phantom were calculated. The screw axis was either parallel or perpendicular to the beam axis. Dose perturbation (relative to dose in homogeneous water phantom) was assessed. Results: Maximum overdose due to backscatter was 10% for the Ti screws, 5% for the CFR-PEEK-AU screws and effectively zero for the CFR-PEEK screws. Maximum underdose due to attenuation was 25% for the Ti screws, 15% for the CFR-PEEK-AU screws and 5% for the CFR-PEEK screws. Conclusion: Titanium screws introduce the largest distortion on the radiation dose distribution. The gold powder added to the CFR-PEEK material improves visibility at the cost of increased dose perturbation. CFR-PEEK screws caused minimal alteration on the dose distribution. This can decrease possible over and underdose of adjacent tissue and thus favorably influence treatment efficiency. The use of such implants has potential clinical advantage in the treatment of neoplastic bone disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-374: Dosimetric Effects of Irradiation Through a Bilateral Hip Prosthesis in a MRI Linac

Purpose: To evaluate the interface effects when irradiating through a hip prosthesis in the presence of an orthogonal 1.5 T magnetic field using Monte Carlo simulations. Methods: A 20×20×38 cm virtual phantom with two 5×5×5 cm sections of bilateral titanium hip prosthesis was created in GPU-based Monte Carlo (MC) algorithm (GPUMCD, Elekta AB, Stockholm Sweden). The lateral prosthesis spacing was based on a representative patient CT scan. A treatment SAD of 143.5 cm was chosen, corresponding to the Elekta AB MRI Linac and the beam energy distribution was sampled from a histogram representing the true MRI Linac spectrum. A magnetic field of 1.5 T was applied perpendicular to the plane of irradiation. Dose was calculated, in voxels of side 1 mm, for 2×2, 5×5, and 10×10 cm treatment field sizes with normal beam incidence (gantry at 90° or 270°) and at 5° and 10° from normal, representing the range of incidence through the bilateral prosthesis. Results: With magnetic field ON (B-On) and normal beam incidence the backscatter dose at the interfaces of proximal and distal implants is reduced for all the field sizes compared to the magnetic field OFF (B-Off) case. The absolute reduction in doses at the interface was in the range of 12.93% to 13.16% for the proximal implant and 13.57% to 16.12% for the distal implant. Similarly for the oblique incidences of 5o and 10o the dose in the plane adjacent to the prosthetic implants is lower when the magnetic field is ON. Conclusion: The dosimetric effects of irradiating through a hip prosthesis in the presence of a transverse magnetic field have been determined using MC simulation. The backscatter dose reduction translates into significantly lower hot spots at the prosthetic interfaces, which are otherwise substantially high in the absence of the magnetic field. This project was supported through funding provided by ElektaTM.

60 APPLIED LIFE SCIENCES↗