Search NASA⌕ Search

SEARCH · Search NASA

Results for “LEGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

A distinctive type of ascending prominence - 'Fountain'

Cinematographic observations of solar prominences made at Mauna Loa, Hawaii, during the past few years suggest that there is a well-defined subclass of ascending prominences characterized by closed-system transference of chromospheric material along an arch or loop (up one leg and down the other). While this occurs, the entire prominence envelope steadily rises upward and expands through the corona. These prominences are denoted as 'fountains'. Several examples are described. Fountains appear to be well contained by coronal magnetic fields. Their total kinetic energy is of the order of 10 to the 30th power erg, but dissipation is typically quite slow (over time periods of 100 min or so), so that the correlative disturbances (radio bursts, coronal transients, chromospheric brightenings) are generally not spectacular or nonexistent.

Tandberg-Hanssen, E.↗

Lower body negative pressure - The second manned Skylab mission

Results of orthostatic evaluations of the crew of Skylab 3 with lower body negative pressure (LBNP) stress tests during their 59-d mission are reported. Except for an inflight increase (rather than a decrease) in resting heart rates, results were essentially parallel to those observed in crewmen of the shorter Skylab 2 mission. Exaggerated elevations in heart rate and decreases in pulse pressure during LBNP stress inflight and immediately postflight corresponded to lowered orthostatic tolerance. Large decrements is resting calf size inflight and in total leg volume postflight indicated significant headward fluid shifts as had already been seen in the Skylab 2 crewmen. In addition, decreases in calf circumference gave no certain indication of a plateau over the 59 d inflight. Percentage volume increase in calf size during LBNP stress inflight was greater than those in either preflight or postflight tests.

Johnson, R. L.↗

Evidence for open field lines in Jupiter's magnetosphere

A model for the night-side Jovian magnetic field is derived partly on the basis of theoretical considerations and partly on the basis of the magnetic-field data obtained during the outbound leg of the path of Pioneer 10. This model can explain the observed sawtooth modulation of energetic particle fluxes in terms of closed and open field lines that cannot contain the particles. The model is applicable only to the Jovian magnetotail.

Goertz, C. K.↗

Biomedical technology transfer: Applications of NASA science and technology

The major efforts of the Stanford Biomedical Applications Team Program at the Stanford University School of Medicine for the period from October 1, 1975 to September 31, 1976 are covered. A completed EMG biotelemetry system which monitors the physiological signals of man and animals in space related research is discussed. The results of a pilot study involving lower body negative pressure testing in cardiac patients has been completed as well as the design and construction of a new leg negative pressure unit for evaluating heart patients. This technology utilizes vacuum chambers to stress the cardiovascular system during space flight. Laboratory tests of an intracranial pressure transducer, have been conducted. Extremely stable long term data using capacative pressure sensors has lead to the order of commercially manufactured monitoring systems base. Projects involving commercialization are: flexible medical electrodes, an echocardioscope, a miniature biotelemetry system, and an on-line ventricular contour detector.

Source record↗

Biomedical technical transfer. Applications of NASA science and technology

Lower body negative pressure testing in cardiac patients has been completed as well as the design and construction of a new leg negative unit for evaluating heart patients. This technology is based on NASA research, using vacuum chambers to stress the cardiovascular system during space flight. Additional laboratory tests of an intracranial pressure transducer, have been conducted. Three new biomedical problems to which NASA technology is applicable are also identified. These are: a communication device for the speech impaired, the NASA development liquid-cooled garment, and miniature force transducers for heart research.

Source record↗

Magnitude of 64-m elevation axis movements due to alidade temperature changes

In projected very-long baseline interferometry (VLBI) work a reference point for 64-m antennas is the intersection of the elevation and azimuth axes. A minimum-level effort at DSS 14 to determine the magnitude of the effect of diurnal changes in the temperature of the alidade legs on the height of the elevation axis is described. The thermal expansion between the lowest recorded temperature -3 C (27 F) and the highest, 36 C (97 F), over the period covered was 8.9 mm (0.35 in.).

Hung, N. T.↗

Biomedical technology transfer: Bioinstrumentation for cardiology, neurology, and the circulatory system

Developments in applying aerospace medical technology to the design and production of medical equipment and instrumentation are reported. Projects described include intercranial pressure transducers, leg negative pressure devices, a synthetic speech prosthesis for victims of cerebral palsy, and a Doppler blood flow instrument. Commercialization activities for disseminating and utilizing NASA technology, and new biomedical problem areas are discussed.

Source record↗

Coastal wave measurements during passage of tropical storm Amy

Aerial photographic and laser profilometer data of waves generated by tropical storm Amy are presented. The data mission consisted primarily of two legs, one in the direction of the wind waves, and the second along the direction of swell propagation, using Jennette's Pier at Nags Head, North Carolina, as a focal point. At flight time, Amy's center was 512 nmi from shore and had maximum winds of 60 knots. The storm's history is presented, along with a satellite photograph, showing the extent of the storm on the day of the flight. Flight ground tracks are presented along with sample aerial photographs of the wave conditions showing approximate wavelength and direction. Sample wave energy spectra are presented both from the laser profilometer onboard the aircraft, and from the Corps of Engineers Research Center (CERC) shore gauge at Nags Head, North Carolina.

Morris, W. D.↗

Skylab 2 crew observations and summary

Signs and symptoms experienced during weightlessness ranged from a sensation of fullness in the head to a strange body posture and the sensation of fluid drainage out of the legs. There was no vestibular sense of the upright whatsoever unless the crewmember happened to look at the earth; motion sickness was not a clinical problem. The ability to maintain physical fitness through exercise and the caloric demand remained just about the same as they do on the ground after initial adjustment.

Kerwin, J. P.↗

Biostereometric analysis of body form

Four-camera stereophotogrammetry of Skylab crewmen, preflight and postflight, revealed a loss of volume of one to one and one-half liters from the legs, much of which was replaced during the first 4 postflight days. It is estimated that about one third of the loss represents partial atrophy due to relative disuse in zero-gravity, the remainder being due to a deficit in body fluid. Reduction in volume of the abdomen has also been noted.

Whittle, M. W.↗

Evaluation of the electromechanical properties of the cardiovascular system after prolonged weightlessness

Devices and techniques for measuring and analyzing systolic time intervals and quantitative phonocardiograms were initiated during Apollo 17. The data show that the systolic time interval from Apollo 17 crewmen remained elevated longer postflight than the response criteria of heart rate, blood pressure, and percent change in leg volume all of which had returned to preflight levels by the second day postflight. Although the systolic time interval values were only slightly outside the preflight fiducial limits, this finding suggested that: the analysis of systolic time intervals may help to identify the mechanisms of postflight orthostatic intolerance by virtue of measuring ventricular function more directly and, the noninvasive technique may prove useful in determining the extent and duration of cardiovascular instability after long duration space flight. The systolic time intervals obtained on the Apollo 17 crewmen during lower body negative pressure were similar to those noted in patients with significant heart disease.

Bergman, S. A., Jr.↗

Exerciser

The Mark I exerciser which was added for the second and third Skylab missions, was used for a number of arm and leg exercises. This unit is a modified version of a commercial device. This is an iso-kinetic, or constant velocity, exerciser which retards the speed at which the user is allowed to move. The user applies a maximum effort and the device automatically varies the opposing resistance to maintain speed of translation at a constant preselected value.

Lem, J. D.↗

Labyrinth and cerebral-spinal fluid pressure changes in guinea pigs and monkeys during simulated zero G

This study was undertaken to explore the hypothesis that shifts of body fluids from the legs and torso toward the head contribute to the motion sickness experienced by astronauts and cosmonauts. The shifts in body fluids observed during zero-G exposure were simulated by elevating guinea pigs' and monkeys' torsos and hindquarters. Cerebral-spinal fluid pressure was recorded from a transducer located in a brain ventricle; labyrinth fluid pressure was recorded from a pipette cemented in a hole in a semicircular canal. An anticipated divergence in cerebral-spinal fluid pressure and labyrinth fluid pressure during torso elevation was not observed. The results of this study do not support a fluid shift mechanism of zero-G-induced motion sickness. However, a more complete test of the fluid shift mechanism would be obtained if endolymph and perilymph pressure changes were determined separately; we have been unable to perform this test to date.

Parker, D. E.↗

Planetary atmospheres with mass spectrometers carried on high-speed probes or satellites

Earth satellite-borne mass spectrometers are considered, taking into account the identification of atomic oxygen in the thermosphere with an 'open' source mass spectrometer flown on a sounding rocket, the conventional closed-source instrument, the mass spectrometers on the Atmosphere Explorer satellites, and mass spectrometer electron multiplier output. A description is presented of mass spectrometers and planetary entry probes. Attention is given to an attempt to obtain an atmospheric composition profile with a terrestrial entry probe, the descending trajectory in the early orbits of the Atmosphere Explorer C satellite, and the molecular nitrogen densities for the descending legs of the orbits. It is pointed out that chemical reactions on the surfaces of the mass spectrometer make the measurement of reactive atmospheric species such as atomic oxygen very difficult.

Nier, A. O.↗

Propulsion cycle effects for a two-fan V/STOL aircraft

This paper discusses the results of an in-depth study investigating the impacts of variable pitch, geared turbofan cycle parameters on a two-fan, subsonic, V/STOL aircraft. Variations in fan pressure ratio, compressor pressure ratio and combustor exit temperature are presented as they affect critical mission legs, aircraft performance, engine thrust-to-weight ratio and as a total systems impact in terms of aircraft takeoff gross weight. Several parameters have counter acting components which, when combined, synergistically result in an optimum value for that parameter. Careful attention has been paid to the changes in aircraft installation penalties associated with each cycle parameter.

Feddersen, R. E.↗

Low Reynolds number flow past a blunt axisymmetric body at angle of attack

Low Reynolds number flow of an ideal gas over a blunt axisymmetric body of large half-angle at small angles of attack is investigated, for the case of laminar hypersonic flow. Time-varying viscous shock layer equations describing the flowfield are obtained from the full Navier-Stokes system by keeping terms to second order in the inverse square root of Re in both viscous and inviscid regions; the equations are valid for moderate to high Re. Drag, skin friction, and heating rates were obtained at small (or zero) angles of attack. Conditions experienced by planetary entry probes during the high-altitude (early) legs of an atmospheric entry trajectory are pertinent to the problem.

Kumar, A.↗

Extension of atomic nitrogen measurements into the lower thermosphere

Special operating modes of the open source neutral mass spectrometer (OSS) on the Atmosphere Explorer C permit the measurement of odd nitrogen (N + NO) number densities between 180 and 450 km. By using optical measurements of NO concentrations from the ultraviolet nitric oxide experiment on AE-C, number densities of N are obtained. Altitude profiles for the midlatitude legs of three orbits in the late spring of 1974 are presented and compared with densities predicted by the AE-C (OSS) empirical N model at 375 km. Atomic nitrogen appeared to be in diffusive equilibrium at least above 200 km in each of the orbits studied. A typical number density of N at 200 km, 0900 LST, and 40 deg N latitude in late May 1974 is 30 million per cu cm.

Engebretson, M. J.↗

Wake characteristics of a tower for the DOE-NASA MOD-1 wind turbine

A 1/40th scale model of a tower concept designed for a MOD-1 wind power turbine was tested in a low speed wind tunnel. Wake wind speed profiles were measured, and from these were determined local values of wake minimum velocity ratio, average velocity ratio, and width over a range of tower elevations and wind approach angles. Comparison with results from two other all tubular models (MOD-0 and eight leg designs) tested earlier in the same tunnel indicated that wake width and flow blockage at the rotor plane of rotation were slightly larger for the MOD-1 tower than for the other two models. The differences in wake characteristics were attributed to differences in tower geometry and member dimensions.

Savino, J. M.↗