Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Commissioning of horizontal-bend superconducting magnet for Jefferson Lab's 11-GeV super high momentum spectrometer

Commissioning characteristics of the Superconducting High Momentum Spectrometer (SHMS) Horizontal Bend (HB) magnet was presented. Pre-commissioning peer review of the magnet uncovered issues with eddy currents in the thermal shield, resulting in additional testing and modeling of the magnet. A three-stage test plan was discussed. A solution of using a small dump resistor and a warm thermal shield was presented. Analyses illustrated that it was safe to run the magnet to full test current. As a result, the HB magnet was successfully cooled to 4 K and reached its maximum test current of 4000 A.

47 OTHER INSTRUMENTATION↗

Technical Note: Response measurement for select radiation detectors in magnetic fields

Purpose: Dose response to applied magnetic fields for ion chambers and solid state detectors has been investigated previously for the anticipated use in linear accelerator–magnetic resonance devices. In this investigation, the authors present the measured response of selected radiation detectors when the magnetic field is applied in the same direction as the radiation beam, i.e., a longitudinal magnetic field, to verify previous simulation only data. Methods: The dose response of a PR06C ion chamber, PTW60003 diamond detector, and IBA PFD diode detector is measured in a longitudinal magnetic field. The detectors are irradiated with buildup caps and their long axes either parallel or perpendicular to the incident photon beam. In each case, the magnetic field dose response is reported as the ratio of detector signals with to that without an applied longitudinal magnetic field. The magnetic field dose response for each unique orientation as a function of magnetic field strength was then compared to the previous simulation only studies. Results: The measured dose response of each detector in longitudinal magnetic fields shows no discernable response up to near 0.21 T. This result was expected and matches the previously published simulation only results, showing no appreciable dose response with magnetic field. Conclusions: Low field longitudinal magnetic fields have been shown to have little or no effect on the dose response of the detectors investigated and further lend credibility to previous simulation only studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydrostatic Level Sensors as High Precision Ground Motion Instrumentation for Tevatron and Other Energy Frontier Accelerators

Particle accelerators require very tight tolerances on the alignment and stability of their elements: magnets, accelerating cavities, vacuum chambers, etc. In this article we describe the Hydrostatic Level Sensors (HLS) for very low frequency measurements used in a variety of facilities at Fermilab. We present design features of the sensors, outline their technical parameters, describe their test and calibration procedures, discuss different regimes of operation and give few illustrative examples of the experimental data. Detail experimental results of the ground motion measurements with these detectors will be presented in subsequent papers.

43 PARTICLE ACCELERATORS↗

Physics-based Tests to Identify the Accuracy of Solar Wind Ion Measurements: A Case Study with the Wind Faraday Cups

We present techniques for comparing measurements of velocity, temperature, and density with constraints imposed by the plasma physics of magnetized bi-Maxwellian ions. Deviations from these physics-based constraints are interpreted as arising from measurement errors. Two million ion spectra from the Solar Wind Experiment Faraday Cup instruments on the Wind spacecraft are used as a case study. The accuracy of velocity measurements is determined by the fact that differential flow between hydrogen and helium should be aligned with the ambient magnetic field. Modeling the breakdown of field alignment suggests velocity uncertainties are less than 0.16% in magnitude and 3deg in direction. Temperature uncertainty is found by examining the distribution of observed temperature anisotropies in high-beta solar wind intervals where the firehose, mirror, and cyclotron microinstabilities should drive the distribution to isotropy. The presence of a finite anisotropy at high beta suggests overall temperature uncertainties of 8%. Hydrogen and helium number densities are compared with the electron density inferred from observations of the local electron plasma frequency as a function of solar wind speed and year. We find that after accounting for the contribution of minor ions, the results are consistent with a systematic offset between the two instruments of 34%. The temperature and density methods are sensitive to non-Maxwellian features such as heat flux and proton beams and as a result are more suited to slow solar wind where these features are rare. These procedures are of general use in identifying the accuracy of observations from any solar wind ion instrument.

Kasper, J. C.↗

Pulsed thrust measurements using electromagnetic calibration techniques

A thrust stand for accurately measuring impulse bits, which ranged from 10-1000 {mu}N s using a noncontact electromagnetic calibration technique is described. In particular, a permanent magnet structure was designed to produce a uniform magnetic field, and a multiturn coil was made to produce a calibration force less than 10 mN. The electromagnetic calibration force for pulsed thrust measurements was linear to the coil current and changed less than 2.5% when the distance between the coil and magnet changed 6 mm. A pulsed plasma thruster was first tested on the thrust stand, and afterward five single impulse bits were measured to give a 310 {mu}N s average impulse bit. Uncertainty of the measured impulse bit was analyzed to evaluate the quality of the measurement and was found to be 10 {mu}N s with 95% credibility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity of magnetic field-line pitch angle measurements to sawtooth events in tokamaks

The sensitivity of the pitch angle profiles measured by the motional Stark effect (MSE) diagnostic to the evolution of the safety factor, q, profiles during the tokamak sawtooth events has been investigated for Korea Superconducting Tokamak Advanced Research (KSTAR). An analytic relation between the tokamak pitch angle, γ, and q estimates that Δγ ∼ 0.1° is required for detecting Δq ∼ 0.05 near the magnetic axis (not at the magnetic axis, though). The pitch angle becomes less sensitive to the same Δq for the middle and outer regions of the plasma (Δγ ∼ 0.5°). At the magnetic axis, it is not straightforward to directly relate the γ sensitivity to Δq since the gradient of γ(R), where R is the major radius of the tokamak, is involved. Many of the MSE data obtained from the 2015 KSTAR campaign, when calibrated carefully, can meet these requirements with the time integration down to 10 ms. The analysis with the measured data shows that the pitch angle profiles and their gradients near the magnetic axis can resolve the change of the q profiles including the central safety factor, q{sub 0}, during the sawtooth events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A scanning Hall probe microscope for high resolution magnetic imaging down to 300 mK

We present the design, construction, and performance of a low-temperature scanning Hall probe microscope with submicron lateral resolution and a large scanning range. The detachable microscope head is mounted on the cold flange of a commercial {sup 3}He-refrigerator (Oxford Instruments, Heliox VT-50) and operates between room temperature and 300 mK. It is fitted with a three-axis slip-stick nanopositioner that enables precise in situ adjustment of the probe location within a 6x6x7 mm{sup 3} space. The local magnetic induction at the sample surface is mapped with an easily changeable microfabricated Hall probe [typically GsAs/AlGaAs or AlGaAs/InGaAs/GaAs Hall sensors with integrated scanning tunnel microscopy (STM) tunneling tips] and can achieve minimum detectable fields {>=}10 mG/Hz{sup 1/2}. The Hall probe is brought into very close proximity to the sample surface by sensing and controlling tunnel currents at the integrated STM tip. The instrument is capable of simultaneous tunneling and Hall signal acquisition in surface-tracking mode. We illustrate the potential of the system with images of superconducting vortices at the surface of a Nb thin film down to 372 mK, and also of labyrinth magnetic-domain patterns of an yttrium iron garnet film captured at room temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A temporally and spatially resolved electron density diagnostic method for the edge plasma based on Stark broadening

An electron density diagnostic (≥10{sup 10} cm{sup −3}) capable of high temporal (ms) and spatial (mm) resolution is currently under development at Oak Ridge National Laboratory. The diagnostic is based on measuring the Stark broadened, Doppler-free spectral line profile of the n = 6–2 hydrogen Balmer series transition. The profile is then fit to a fully quantum mechanical model including the appropriate electric and magnetic field operators. The quasi-static approach used to calculate the Doppler-free spectral line profile is outlined here and the results from the model are presented for H-δ spectra for electron densities of 10{sup 10}–10{sup 13} cm{sup −3}. The profile shows complex behavior due to the interaction between the magnetic substates of the atom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast island phase identification for tearing mode feedback control on J-TEXT tokamak

A new method to control the tearing mode (TM) in tokamaks has been proposed [Q. Hu and Q. Yu, Nucl. Fusion 56, 034001 (5pp.) (2016)], according to which, the external resonant magnetic perturbation needs to be applied in certain magnetic island phase regions. Therefore, it is very important to identify the helical phase of magnetic islands in real time. The TM in tokamak plasmas is normally rotating and carries magnetic oscillations, which are known as Mirnov oscillations and can be detected by Mirnov probes. When the O-point or X-point of the magnetic island passes through the probe, the signal will experience a zero-crossing. A poloidal Mirnov probe array and a corresponding island phase identification method are presented. A field-programmable gate array is used to provide the magnetic island helical phase in real time by using multichannel zero crossing detection. This system has been developed on the J-TEXT tokamak and works well. This paper introduces the establishment of the fast magnetic island phase identifying system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rotatable spin-polarized electron source for inverse-photoemission experiments

We present a ROtatable Spin-polarized Electron source (ROSE) for the use in spin- and angle-resolved inverse-photoemission (SR-IPE) experiments. A key feature of the ROSE is a variable direction of the transversal electron beam polarization. As a result, the inverse-photoemission experiment becomes sensitive to two orthogonal in-plane polarization directions, and, for nonnormal electron incidence, to the out-of-plane polarization component. We characterize the ROSE and test its performance on the basis of SR-IPE experiments. Measurements on magnetized Ni films on W(110) serve as a reference to demonstrate the variable spin sensitivity. Moreover, investigations of the unoccupied spin-dependent surface electronic structure of Tl/Si(111) highlight the capability to analyze complex phenomena like spin rotations in momentum space. Essentially, the ROSE opens the way to further studies on complex spin-dependent effects in the field of surface magnetism and spin-orbit interaction at surfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heavy ion beam physics at Facility for Rare Isotope Beams

The Facility for Rare Isotope Beams (FRIB) will be the world's premier rare-isotope beam facility. Experiments with the majority (~80%) of the isotope predicted to exist will become available. The FRIB facility is based on a superconducting (SC) heavy ion linac with output energy above 200 MeV/u for any ions at beam power of 400 kW. FRIB includes a target facility for in-flight production of rare isotopes. A three-stage fragment separator will be used to prepare fast rare isotope beams with high-purity for nuclear physics experiments. The installation work of the accelerator and experimental systems is approaching completion and multi-stage beam commissioning activities started in summer 2017 with expected project completion in early 2022. In conclusion, the commencement of operation for users' experiments is planned immediately following the project completion.

43 PARTICLE ACCELERATORS↗

Modelling and Evaluation of Spectra in Beam Aided Spectroscopy

The evaluation of active beam induced spectra requires advanced modelling of both active and passive features. Three types of line shapes are addressed in this paper: Thermal spectra representing Maxwellian distribution functions described by Gaussian-like line shapes, secondly broad-band fast ion spectra with energies well above local ion temperatures, and, finally, the narrow lines shapes of the equi-spaced Motion Stark multiplet (MSE) of excited neutral beam particles travelling through the magnetic field confining the plasma. In each case additional line shape broadening caused by Gaussian-like instrument functions is taken into account. Further broadening effects are induced by collision velocity dependent effective atomic rates where the observed spectral shape is the result of a convolution of emission rate function and velocity distribution function projected into the direction of observation. In the case of Beam Emission Spectroscopy which encompasses the Motional Stark features, line broadening is also caused by the finite angular spread of injected neutrals and secondly by a ripple in the acceleration voltage associated with high energy neutral beams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A linear radio frequency plasma reactor for potential and current mapping in a magnetized plasma

Langmuir probe measurements in front of high power ion cyclotron resonant frequency antennas are not possible or simply too noisy to be analyzed properly. A linear experiment is a radio frequency (RF) magnetized plasma discharge reactor designed to probe the rectified potential in front of such antennas but at low power level (1 kW) to next improve antenna design and mitigate sheath effects. The maximum magnetic field is 0.1 T, and the RF amplifier can work between 10 kHz and 250 MHz allowing ion cyclotron resonances for argon or helium. The first measurements with no magnetic field are presented here, especially 2D potential maps extracted from the RF compensated probe measurements yield ni ≈ 10{sup 15} m{sup −3} and Te ≈ 2 eV for RF power lower than 100 W. Series resonances in the chamber are highlighted and allow to deduce the plasma parameters from a simple equivalent impedance model of the plasma in helium gas. Next studies will be focused on magnetized plasmas and especially magnetized RF sheaths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Co-Investigator Proposal for Enstrophy - - Filamentation of Auroral Currents

Cornell University provided three instruments for the Enstrophy experiment: an electric field meter, a plasma wave receiver, and a magnetometer for measuring FAC. The electric field meter consisted of a 6 m Weitzmann boom system with analog signal processing and 12 bit ADC, which yielded one electric field component instantaneously and a two dimensional electric field every half spin. The plasma wave receiver used the same sensing system with the addition of pre-amplifiers in the spheres to sense plasma waves up to and including the electron Langmuir frequency. Signal processing employed a variety of continuous and snap shot techniques depending on the frequency range and band width. The science magnetometer provided by Cornell University was a Billingsly design fluxgate previously used on spacecraft missions but without radiation hardening. The magnetometer was mounted on a one meter, stiff aluminum "flop-down" boom. The Enstrophy payload was launched on february 11, 1999. Because of a design flaw in the event timers, the magnetometer boom was deployed before the payload despun. As a result the magnetometer separated mechanically from the boom but maintained electrical connection. This was confirmed by the calculation of the scalar magnetic field from all three vector components of the magnetic field. However, the individual vector values had no scientific value. The electric field and plasma wave instrumentation worked as designed. The data from these instruments was provided to the University of New Hampshire and to the Principal Investigator, as proposed.

Kintner, Paul M.↗

Study of the operation temperature in the spin-exchange relaxation free magnetometer

We study the influence of the cell temperature on the sensitivity of the spin-exchange relaxation free (SERF) magnetometer and analyze the possibility of operating at a low temperature. Utilizing a 25 × 25 × 25 mm{sup 3} Cs vapor cell with a heating temperature of 85 {sup ∘}C, which is almost half of the value of potassium, we obtain a linewidth of 1.37 Hz and achieve a magnetic field sensitivity of 55 fT/Hz{sup 1/2} in a single channel. Theoretical analysis shows that fundamental sensitivity limits of this device with an active volume of 1 cm{sup 3} could approach 1 fT/Hz{sup 1/2}. Taking advantage of the higher saturated vapor pressure, SERF magnetometer based on Cs opens up the possibility for low cost and portable sensors and is particularly appropriate for lower temperature applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial heterodyne spectroscopy for fast local magnetic field measurements of magnetized fusion plasmas

A novel spectroscopy diagnostic for measuring internal magnetic fields in high temperature magnetized plasmas has been developed. It involves spectrally resolving the Balmer- α (656 nm) neutral beam radiation split by the motional Stark effect with a spatial heterodyne spectrometer (SHS). The unique combination of high optical throughput (3.7 mm 2 sr) and spectral resolution (δλ ~ 0.1 nm) allows these measurements to be made with time resolution $\ll$1 ms. The high throughput is effectively utilized by incorporating a novel geometric Doppler broadening compensation technique in the spectrometer. The technique significantly reduces the spectral resolution penalty inherent to using large area, high-throughput optics while still collecting the large photon flux provided by such optics. In this work, fluxes of order 10 10 s –1 support the measurement of deviations of <5 mT (Δ λ Stark ~ 10 –4 nm) in the local magnetic field with 50 µs time resolution. Example high time resolution measurements of the pedestal magnetic field throughout the ELM cycle of a DIII-D tokamak plasma are presented. Local magnetic field measurements give access to the dynamics of the edge current density, which is essential to understanding stability limits, edge localized mode generation and suppression, and predicting performance of H-mode tokamaks.

47 OTHER INSTRUMENTATION↗

THE INTERPRETATION OF ROTATION MEASURES IN THE PRESENCE OF INHOMOGENEOUS FOREGROUND SCREENS

We analyze the redshift evolution of the rotation measure (RM) in the Taylor et al. data set, based on NVSS radio data at 21 cm, and compare with results from our previous work based on RMs determined at lower wavelengths, e.g., 6 cm. We find that, in spite of the same analysis, Taylor et al.'s data set produces neither an increase of the RM dispersion with redshift nor the correlation of RM strength with Mg II absorption lines that we found previously. We develop a simple model to understand this discrepancy. The model assumes that the Faraday rotators, namely the QSO's host galaxy and the intervening Mg II host galaxies along the line of sight, contain partially inhomogeneous RM screens. We find that this leads to an increasing depolarization toward longer wavelengths and to wavelength-dependent RM values. In particular, due to cosmological redshift, observations at fixed wavelength of sources at different redshift are affected differently by depolarization and are sensitive to different Faraday active components. For example, at 21 cm the polarized signal is averaged out by inhomogeneous Faraday screens and the measured RM mostly reflects the Milky Way contributions for low-redshift QSOs whereas polarization is relatively unaffected for high-redshift QSOs. Similar effects are produced by intervening galaxies acting as inhomogeneous screens. Finally, we assess the performance of RM synthesis on our synthetic models and conclude that the study of magnetic fields in galaxies as a function of cosmic time will benefit considerably from the application of such a technique, provided there is sufficient instrumental bandwidth. For this purpose, high-frequency channels appear preferable but not strictly necessary.

79 ASTRONOMY AND ASTROPHYSICS↗