Search NASA⌕ Search

SEARCH · Search NASA

Results for “MINORITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Integral Reactor Containment Condensation Model and Experimental Validation

This NEUP funded project, NEUP 12-3630, is for experimental, numerical and analytical studies on high-pressure steam condensation phenomena in a steel containment vessel connected to a water cooling tank, carried out at Oregon State University (OrSU) and the University of Wisconsin at Madison (UW-Madison). In the three years of investigation duration, following the original proposal, the planned tasks have been completed: (1) Performed a scaling study for the full pressure test facility applicable to the reference design for the condensation heat transfer process during design basis accidents (DBAs), modified the existing test facility to route the steady-state secondary steam flow into the high pressure containment for controllable condensation tests, and extended the operations at negative gage pressure conditions (OrSU). (2) Conducted a series of DBA and quasi-steady experiments using the full pressure test facility to provide a reliable high pressure condensation database (OrSU). (3) Analyzed experimental data and evaluated condensation model for the experimental conditions, and predicted the prototypic containment performance under accidental conditions (UW-Madison). A film flow model was developed for the scaling analysis, and the results suggest that the 1/3 scaled test facility covers large portion of laminar film flow, leading to a lower average heat transfer coefficient comparing to the prototypic value. Although it is conservative in reactor safety analysis, the significant reduction of heat transfer coefficient (50%) could under estimate the prototypic condensation heat transfer rate, resulting in inaccurate prediction of the decay heat removal capability. Further investigation is thus needed to quantify the scaling distortion for safety analysis code validation. Experimental investigations were performed in the existing MASLWR test facility at OrST with minor modifications. A total of 13 containment condensation tests were conducted for pressure ranging from 4 to 21 bar with three different static inventories of non-condensable gas. Condensation and heat transfer rates were evaluated employing several methods, notably from measured temperature gradients in the HTP as well as measured condensate formation rates. A detailed mass and energy accounting was used to assess the various measurement methods and to support simplifying assumptions required for the analysis. Condensation heat fluxes and heat transfer coefficients are calculated and presented as a function of pressure to satisfy the objectives of this investigation. The major conclusions for those tests are summarized below: (1) In the steam blow-down tests, the initial condensation heat transfer process involves the heating-up of the containment heat transfer plate. An inverse heat conduction model was developed to capture the rapid transient transfer characteristics, and the analysis method is applicable to SMR safety analysis. (2) The average condensation heat transfer coefficients for different pressure conditions and non-condensable gas mass fractions were obtained from the integral test facility, through the measurements of the heat conduction rate across the containment heat transfer plate, and from the water condensation rates measurement based on the total energy balance equation. 15 (3) The test results using the measured HTP wall temperatures are considerably lower than popular condensation models would predict mainly due to the side wall conduction effects in the existing MASLWR integral test facility. The data revealed the detailed heat transfer characteristics of the model containment, important to the SMR safety analysis and the validation of associated evaluation model. However this approach, unlike separate effect tests, cannot isolate the condensation heat transfer coefficient over the containment wall, and therefore is not suitable for the assessment of the condensation heat transfer coefficient against system pressure and noncondensable gas mass fraction. (4) The average condensation heat transfer coefficients measured from the water condensation rates through energy balance analysis are appropriate, however, with considerable uncertainties due to the heat loss and temperature distribution on the containment wall. With the consideration of the side wall conduction effects, the results indicate that the measured heat transfer coefficients in the tests is about 20% lower than the prediction of Dehbi’s correlation, mainly due to the side wall conduction effects. The investigation also indicates an increase in the condensation heat transfer coefficient at high containment pressure conditions, but the uncertainties invoked with this method appear to be substantial. (5) Non-condensable gas in the tests has little effects on the condensation heat transfer at high elevation measurement ports. It does affect the bottom measurements near the water level position. The results suggest that the heavier non-condensable gas is accumulated in the lower portion of the containment due to stratification in the narrow containment space. The overall effects of the non-condensable gas on the heat transfer process should thus be negligible for tall containments of narrow condensation spaces in most SMR designs. Therefore, the previous correlations with noncondensable gas effects are not appropriate to those small SMR containments due to the very poor mixing of steam and non-condensable gas. The MELCOR simulation results agree with the experimental data reasonably well. However, it is observed that the MELCOR overpredicts the heat flux for all analyzed tests. The MELCOR predicts that the heat fluxes for CCT’s approximately range from 30 to 45 kW/m2 whereas the experimental data (averaged) ranges from about 25 to 40 kW/m2. This may be due to the limited availability of liquid film models included in MELCOR. Also, it is believed that due to complex test geometry, measured temperature gradients across the heat transfer plate may have been underestimated and thus the heat flux had been underestimated. The MELCOR model predicts a film thickness on the order of 100 microns, which agrees very well with film flow model developed in this study for scaling analysis. However, the expected differences in film thicknesses for near vacuum and near atmospheric test conditions are not significant. Further study on the behavior of condensate film is expected to refine the simulation results. Possible refinements include but are not limited to, the followings: CFD simulation focusing on the liquid film behavior and benchmarking with experimental analyses for simpler geometries. 16 1 INTRODUCTION This NEUP funded project, NEUP 12-3630, is for experimental, numerical and analytical studies on high-pressure steam condensation phenomena in a steel containment vessel connected to a water cooling tank, carried out at Oregon State University (OrSU) and the University of Wisconsin at Madison (UW-Madison). The experimental results are employed to validate the containment condensation model in reactor containment system safety analysis code for integral SMRs. Such a containment condensation model is important to demonstrate the adequate cooling. In the three years of investigation, following the original proposal, the following planned tasks have been completed: (1) Performed a scaling study for the full pressure test facility applicable to the reference design for the condensation heat transfer process during design basis accidents (DBAs), modified the existing test facility to route the steady-state secondary steam flow into the high pressure containment for controllable condensation tests, and extended the operations at negative gage pressure conditions (OrSU). (2) Conducted a series of DBA and quasi-steady experiments using the full pressure test facility to provide a reliable high pressure condensation database (OrSU). (3) Analyzed experimental data and evaluated condensation model for the experimental conditions, and predicted the prototypic containment performance under accidental conditions (UW-Madison). The results are applicable to integral Small Modular Reactor (SMR) designs, including NuScale, mPower, Westinghouse SMR, Holtec-160 and other integral reactors with small containments of relatively high pressures under accidental conditions. Testing has been conducted at the OrSU laboratory in the existing MASLWR (Multi-Application Small Light Water Reactor) integral test facility sponsored by the US Department of Energy. Its highpressure stainless steel containment model (~2 MPa) is scaled to the NuScale SMR currently under development at NuScale Power, Inc.. Minor modifications to the model containment have been made to control the non-condensable gas fraction and to utilize the secondary loop stable steam flow for condensation testing. UW-Madison has developed a containment condensation model, which leveraged previous validated containment heat transfer work carried out at UW-Madison, and extended the range of applicability of the model to integral SMR designs that utilize containment vessels of high heat transfer efficiencies. In this final report, the research background and literature survey are presented in Chapter 2 and 3, respectively. The test facility description and modifications are summarized in Chapter 4, and the scaling analysis is introduced in Chapter 5. The tests description, procedures, and data analysis are presented in Chapter 6, while the numerical modeling is presented in Chapter 7, followed by a conclusion section in Chapter 8.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sigma Team for Advanced Actinide Recycle FY2015 Accomplishments and Directions

The Sigma Team for Minor Actinide Recycle (STAAR) has made notable progress in FY 2015 toward the overarching goal to develop more efficient separation methods for actinides in support of the United States Department of Energy (USDOE) objective of sustainable fuel cycles. Research in STAAR has been emphasizing the separation of americium and other minor actinides (MAs) to enable closed nuclear fuel recycle options, mainly within the paradigm of aqueous reprocessing of used oxide nuclear fuel dissolved in nitric acid. Its major scientific challenge concerns achieving selectivity for trivalent actinides vs lanthanides. Not only is this challenge yielding to research advances, but technology concepts such as ALSEP (Actinide Lanthanide Separation) are maturing toward demonstration readiness. Efforts are organized in five task areas: 1) combining bifunctional neutral extractants with an acidic extractant to form a single process solvent, developing a process flowsheet, and demonstrating it at bench scale; 2) oxidation of Am(III) to Am(VI) and subsequent separation with other multivalent actinides; 3) developing an effective soft-donor solvent system for An(III) selective extraction using mixed N,O-donor or all-N donor extractants such as triazinyl pyridine compounds; 4) testing of inorganic and hybrid-type ion exchange materials for MA separations; and 5) computer-aided molecular design to identify altogether new extractants and complexants and theory-based experimental data interpretation. Within these tasks, two strategies are employed, one involving oxidation of americium to its pentavalent or hexavalent state and one that seeks to selectively complex trivalent americium either in the aqueous phase or the solvent phase. Solvent extraction represents the primary separation method employed, though ion exchange and crystallization play an important role. Highlights of accomplishments include: Confirmation of the first-ever electrolytic oxidation of Am(III) in a noncomplexing aqueous solution and submission of this scientific breakthrough as a paper in Science; The first-ever co-crystallization of Am(VI) with UO 2 (NO 3 ) 2 ∙ 6H 2 O, opening the door to a new approach for separating hexavalent actinides as a group; Results showing that three potentially problematic metals will not present risk in ALSEP; Improvement in ALSEP contactor stripping kinetics to acceptable performance; A comparison of centrifugal contactors vs mixer-settlers showing the former performs better in ALSEP stripping; Synthesis of new mixed N,O-donor extractants with enhanced solubility and strength for selective trivalent actinide extraction; Development of computational methods showing promise in prediction of the selectivity of new extractants for trivalent actinides vs lanthanides; An order-of-magnitude improvement in aqueous Am/Eu complexation selectivity of an alternative macrocyclic stripping agent for ALSEP, potentially enabling an option for an Am product stream free from both Ln and Cm. An alternative aqueous combination of dipicolinate complexant and malonate buffer that may present options for ALSEP and TALSPEAK (Trivalent Actinide-Lanthanide Separations by Phosphorus-reagent Extraction from Aqueous Komplexes) type separations. The ALSEP concept is advancing toward a benchtop flowsheet demonstration planned for FY 2016, and a bench-scale test bed at Idaho National Laboratory (INL) will be employed to demonstrate at least one tandem Am oxidation and separation concept. This report outlines the goals of the STAAR, significance of achieving these goals, STAAR organization around the above aims and questions, recent highlights, and future directions. The report also includes a listing of publications, reports, patents, and dissertations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

How grain boundaries affect the efficiency of poly-CdTe solar-cells: A fundamental atomic-scale study of grain boundary dislocation cores using CdTe bi-crystal thin films.

It is now widely accepted that grain boundaries in poly-crystalline CdTe thin film devices have a detrimental effect on the minority carrier lifetimes, the open circuit voltage and therefore the overall solar-cell performance. The goal of this project was to develop a fundamental understanding of the role of grain boundaries in CdTe on the carrier life-time, open-circuit voltage, Voc, and the diffusion of impurities. To achieve this goal, i) CdTe bi-crystals were fabricated with various misorientation angels, ii) the atomic- and electronic structures of the grain boundaries were characterized using scanning transmission electron microscopy (STEM), and iii) first-principles density functional theory modeling was performed on the structures determined by STEM to predict the grain boundary potential. The transport properties and minority carrier lifetimes of the bi-crystal grain boundaries were measured using a variety of approaches, including TRPL, and provided feedback to the characterization and modeling effort about the effectiveness of the proposed models.

14 SOLAR ENERGY↗

Development of Scanning Ultrafast Electron Microscope Capability.

Modern semiconductor devices rely on the transport of minority charge carriers. Direct examination of minority carrier lifetimes in real devices with nanometer-scale features requires a measurement method with simultaneously high spatial and temporal resolutions. Achieving nanometer spatial resolutions at sub-nanosecond temporal resolution is possible with pump-probe methods that utilize electrons as probes. Recently, a stroboscopic scanning electron microscope was developed at Caltech, and used to study carrier transport across a Si p-n junction [ 1 , 2 , 3 ] . In this report, we detail our development of a prototype scanning ultrafast electron microscope system at Sandia National Laboratories based on the original Caltech design. This effort represents Sandia's first exploration into ultrafast electron microscopy.

47 OTHER INSTRUMENTATION↗

Lakeview, Oregon, Disposal Site

9.1 Compliance Summary The Lakeview, Oregon, Uranium Mill Tailings Radiation Control Act (UMTRCA) Title I Disposal Site was inspected September 16 and 17, 2015. Other than some ongoing concern with erosion-control rock riprap degradation, the disposal cell was in good condition. Some minor fence repairs and vegetation removal, and minor erosion repair work along the west site fence is planned. Inspectors identified no other maintenance needs or cause for a follow-up or contingency inspection. Disposal cell riprap is evaluated annually to ensure continued long-term protection of the cell from erosion during a severe precipitation event. Degradation of the rock riprap was first observed at the site in the mid-1990s. Rock gradation monitoring of the riprap on the west side slope has been performed as part of the annual inspection since 1997 to determine the mean diameter (D 50 ) value. As prescribed by the monitoring procedure, the rock monitoring is routinely conducted at random locations. However, at the U.S. Nuclear Regulatory Commission’s (NRC’s) request, the 2015 rock monitoring approach deviated from the normal procedure by using a pre-established monitoring grid in a subset area of the west side slope. This changed the monitoring approach from random sampling to biased sampling. The D 50 value measured during the 2015 gradation monitoring is 2.39 inches, which falls below the original D 50 design size range of 2.7–3.9 inches for the Type B size side slope riprap. At NRC’s request, rock durability monitoring was added to the gradation monitoring in 2009 to monitor durability by rock type. Results of the 2015 durability monitoring showed that74 percent of the total rock sampled is durability class code A rock with an assigned durability class of “highly durable” or durability class code B “durable” rock, and that over 90 percent of the 3-inch or larger rock is durability class code A or B. The rock durability classifications are further explained in Section 9.4.2.2.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low Cost, Epitaxial Growth of II-VI Materials for Multijunction Photovoltaic Cells

Multijunction solar cells have theoretical power conversion efficiencies in excess of 29% under one sun illumination and could become a highly disruptive technology if fabricated using low cost processing techniques to epitaxially grow defect tolerant, thin films on silicon. The PLANT PV/Molecular Foundry team studied the feasibility of using cadmium selenide (CdSe) as the wide band-gap, top cell and Si as the bottom cell in monolithically integrated tandem architecture. The greatest challenge in developing tandem solar cells is depositing wide band gap semiconductors that are both highly doped and have minority carrier lifetimes greater than 1 ns. The proposed research was to determine whether it is possible to rapidly grow CdSe films with sufficient minority carrier lifetimes and doping levels required to produce an open-circuit voltage (Voc) greater than 1.1V using close-space sublimation (CSS).

14 SOLAR ENERGY↗

Summary of ALSEP Test Loop Solvent Irradiation Testing

Separating the minor actinide elements (americium and curium) from the fission product lanthanides is an important step in closing the nuclear fuel cycle. Isolating the minor actinides will allow transmuting them to short lived or stable isotopes in fast reactors, thereby reducing the long-term hazard associated with these elements. The Actinide Lanthanide Separation Process (ALSEP) is being developed by the DOE-NE Material Recovery and Waste Form Development Campaign to accomplish this separation with a single process. To develop a fundamental understanding of the solvent degradation mechanisms for the ALSEP Process, testing was performed in the INL Radiolysis/Hydrolysis Test Loop for the extraction section of the ALSEP flowsheet. This work culminated in the completion of the level two milestone (M2FT-16IN030102021) "Complete ALSEP test loop solvent irradiation test.” This report summarizes the testing performed and the impact of radiation on the ALSEP Process performance as a function of dose.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Parametric and experimentally informed BWR Severe Accident Analysis Utilizing FeCrAl - M3FT-17OR020205041

Iron-chromium-aluminum (FeCrAl) alloys are being considered as advanced fuel cladding concepts with enhanced accident tolerance. At high temperatures, FeCrAl alloys have slower oxidation kinetics and higher strength compared with zirconium-based alloys. FeCrAl could be used for fuel cladding and spacer or mixing vane grids in light water reactors and/or as channel box material in boiling water reactors (BWRs). There is a need to assess the potential gains afforded by the FeCrAl accident-tolerant-fuel (ATF) concept over the existing zirconium-based materials employed today. To accurately assess the response of FeCrAl alloys under severe accident conditions, a number of FeCrAl properties and characteristics are required. These include thermophysical properties as well as burst characteristics, oxidation kinetics, possible eutectic interactions, and failure temperatures. These properties can vary among different FeCrAl alloys. Oak Ridge National Laboratory has pursued refined values for the oxidation kinetics of the B136Y FeCrAl alloy (Fe-13Cr-6Al wt %). This investigation included oxidation tests with varying heating rates and end-point temperatures in a steam environment. The rate constant for the low-temperature oxidation kinetics was found to be higher than that for the commercial APMT FeCrAl alloy (Fe-21Cr-5Al-3Mo wt %). Compared with APMT, a 5 times higher rate constant best predicted the entire dataset (root mean square deviation). Based on tests following heating rates comparable with those the cladding would experience during a station blackout, the transition to higher oxidation kinetics occurs at approximately 1,500°C. A parametric study varying the low-temperature FeCrAl oxidation kinetics was conducted for a BWR plant using FeCrAl fuel cladding and channel boxes using the MELCOR code. A range of station blackout severe accident scenarios were simulated for a BWR/4 reactor with Mark I containment. Increasing the FeCrAl low-temperature oxidation rate constant (3 times and 10 times that of the rate constant for APMT) had a negligible impact on the early stages of the accident and minor impacts on the accident progression after the first relocation of the fuel. At temperatures below 1,500°C, increasing the rate constant for APMT by a factor of 10 still resulted in only minor FeCrAl oxidation. In general, the gains afforded by the FeCrAl enhanced ATF concept with respect to accident sequence timing and combustible gas generation are consistent with previous efforts. Compared with the traditional Zircaloy-based cladding and channel box system, the FeCrAl concept could provide a few extra hours of time for operators to take mitigating actions and/or for evacuations to take place. A coolable core geometry is retained longer, enhancing the ability to stabilize an accident. For example, a station blackout was simulated in which cooling water injection was lost 36 hours after shutdown. The timing to first fuel relocation was delayed by approximately 5 h for the FeCrAl ATF concept compared with that of the traditional Zircaloy-based cladding and channel box system.

36 MATERIALS SCIENCE↗

Analysis of Dust Samples Collected from an In-Service Interim Storage System at the Maine Yankee Nuclear Site.

In July, 2016, the Electric Power Research Institute and industry partners performed a field test at the Maine Yankee Nuclear Site, located near Wiscasset, Maine. The primary goal of the field test was to evaluate the use of robots in surveying the surface of an in-service interim storage canister within an overpack; however, as part of the demonstration, dust and soluble salt samples were collected from horizontal surfaces within the interim storage system. The storage system is a vertical system made by NAC International, consisting of a steel-lined concrete overpack containing a 304 stainless steel (SS) welded storage canister. The canister did not contain spent fuel but rather greater-than-class-C waste, which did not generate significant heat, limiting airflow through the storage system. The surfaces that were sampled for deposits included the top of the shield plug, the side of the canister, and a shelf at the bottom of the overpack, just below the level of the pillar on which the canister sits. The samples were sent to Sandia National Laboratories for analysis. This report summarizes the results of those analyses. Because the primary goal of the field test was to evaluate the use of robots in surveying the surface of the canister within the overpack, collection of dust samples was carried out in a qualitative fashion, using paper filters and sponges as the sampling media. The sampling focused mostly on determining the composition of soluble salts present in the dust. It was anticipated that a wet substrate would more effectively extract soluble salts from the surface that was sampled, so both the sponges and the filter paper were wetted prior to being applied to the surface of the metal. Sampling was accomplished by simply pressing the damp substrate against the metal surface for two minutes, and then removing it. It is unlikely that the sampling method quantitatively collected dust or salts from the metal surface; however, both substrates did extract a significant amount of material. The paper filters collected both particles, trapped within the cellulose fibers of the filter, and salts, while the sponges collected only the soluble salts, with very few particles. Upon delivery to Sandia, both collection media were analyzed using the same methods. The soluble salts were leached from the substrates and analyzed via ion chromatography, and insoluble minerals were analyzed by scanning electron microscopy and energy dispersive X-ray spectroscopy. The insoluble minerals were found to consist largely of terrestrially-derived mineral fragments, dominantly quartz and biotite. Large (mm-sized) aggregates of calcium carbonate, calcium silicate, and calcium aluminum silicate were also present. The aggregates had one flat, smooth surface and one well crystallized surface, and were interpreted to be efflorescence on the inside of the overpack and in the vent, formed by seepage of cement pore fluids through joints in the steel liner of the overpack. Such efflorescence was commonly observed during the boroscope inspection of the storage system at the site. The material may have flaked off and fallen to the point where the dust was collected, or may have brushed off onto the sponges when the robot was retrieved through the inlet vent. Chemical analysis showed that the soluble salts on the shield plug were Ca- and Na-rich, with lesser K and minor Mg; the anionic component was dominated by SO 4 and Cl, with minor amounts of NO 3 . The cation composition of the soluble salts from the overpack shelf and the canister surface was similar to the filter samples, but the anions differed significantly, being dominantly NO 3 with lesser Cl and only trace SO 4 . The salts appear to represent a mixture of sea-salts (probably partially converted to nitrates and sulfates by particle-gas conversion reactions) and continental salt aerosols. Ammonium, a common component in continental aerosols, was not observed and may have been lost by degassing from the canister surface or after collection during sample storage and transportation. The demonstration at Maine Yankee has shown that the robot and sampling method used for the test can successfully be used to collect soluble salts from metal surfaces within an interim storage system overpack. The results were consistent from sample to sample, suggesting that a representative sample of the soluble salts was being collected. However, it is unlikely that the salt samples collected here represent quantitative sampling of the salts on the surfaces evaluated; for that reason, chloride densities per unit area are not presented here. It should also be noted that the relevance to storage systems at the site that contain SNF may be limited, because a heat- generating canister will result in greater airflow through the overpack, affecting dust deposition rates and possibly salt compositions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Crystal Structure Evolution of U-Si Nuclear Fuel Phases as a Function of Temperature

The crystal structure of the U 3 Si 2 line compound in the U-Si system was investigated as a function of temperature from room temperature t o1373 K using high temperature neutron time-of-flight diffraction on the HIPPO diffractometer at LANSCE. The U-Si system is actively researched due to its promise as an accident tolerant nuclear fuel. The simultaneous Rietveld refinement of five histograms from the five HIPPO detector rings provided fundamental datasets for the lattice parameters, anisotropic atomic displacement parameters, and atomic positions as a function of temperature. To explore the possibility of minority phases as a result of the synthesis route and especially due to hyper-stoichiometry, a stoichiometric U 3 Si 2.00 sample and a hyper-stoichiometric U 3 Si 2.01 sample were studied. While minor differences in the anisotropic atomic displacement parameters between the two samples were observed, over the entire investigated temperature range no additional phases were observed. However, significant differences in the thermal expansion behavior were identified between the two compositions that warrant future investigations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Evaluation of the CHKED Multi-Elemental Analysis and Software

The Hybrid K-edge Densitometer (HKED) is a high precision safeguards assay system developed by Ottmar and Eberle [1] for quantification of the U and Pu concentrations of dissolver solutions in spent nuclear fuel reprocessing. The HKED measurement supplements traditional destructive assay methods such as Isotope Dilution Mass Spectrometry (IDMS) and is an essential component of the international safeguards program implementation at these facilities. The Canberra Hybrid K-Edge Densitometry (CHKED) software was recently developed by Canberra Industries to better address the changing composition of the nuclear fuel cycle by addition of a multi-elemental analysis capability to the K-Edge transmission measurement. Our evaluation of the CHKED software was performed at the request of the International Atomic Energy Agency (IAEA) to examine the functionality and performance of the CHKED software and algorithms and identify potential areas for improvement of the software. The reader is assumed to be familiar with the HKED technique and its current implementation in safeguards assay of U and Pu in the nuclear fuel cycle. The Canberra Hybrid K-Edge Densitometry CHKED software replicates functionality of the older VMSbased Hybrid K-Edge Densitometer (HKED) software and incorporates additional analysis algorithms and tools. When the traditional HKED analyses are selected, the CHKED software appears to faithfully reproduce the measurement results as reported by the older software. The CHKED software includes a Multi-elemental K-Edge (MEKED) analysis based in part on algorithms devised at Los Alamos National Laboratory. In principle, the MEKED analysis represents a significant advancement over the traditional HKED analysis, providing a capability to analyze the actinide concentrations from complex solutions, such as low U:Pu ratios (e.g., U:Pu = 1:1) including additional minor actinide components such as Np and Am. However, this MEKED analysis is somewhat limited by reliance on a region of interest (ROI) analysis of the spectrum, the need for extensive calibration measurements and a simplistic interpretation of the KED transmission spectrum. Finally, the MEKED algorithm set associated with the CHKED software (V1.0) acquired by Oak Ridge National Laboratory (ORNL) from Canberra Industries does not seem to be “finished” (e.g., the MEKED analysis seems to only determine measurement results for two actinides with while results for the minor actinides appear to be highly dependent on declaration values).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

FY19 Status of the Full Circumference Examination of the Inner Container Closure Weld Region for Selected 3013 DE Containers

One of the main focus areas of the 3013 Surveillance Program is a thorough evaluation of the inner container closure weld region (ICCWR) opened for destructive examination (DE). As part of the protocol to investigate the corrosion in the ICCWR a laser confocal microscope (LCM) is used to perform close visual examination of the surface and measurements of corrosion features on the surface. In FY17, DE containers from FY13 through FY16 were evaluated to select candidates for a full circumference analysis of the ICCWR. In FY18, the selected DE containers for full circumference evaluation (FCE) were processed according to the ICCWR protocol and LCM data collection was completed for the full circumference only for FY15 DE07. In FY19 the remaining DE containers were completed. The ICCWR protocol was completed as follows: (1) the FCE containers were sectioned into quarters and the weld removed to access the ICCWR; (2) a series of images of the ICCWR full circumference were taken using a stereo microscope and assembled into panoramic views; (3) SEM/EDS analysis performed on selected sections showed what is most likely corrosion products on the surface and chlorides randomly dispersed; (4) the presence of chlorides was also confirmed with ion chromatography of citric acid washes, in which FY15 DE07 and FY16 DE05 showed a significant amount of chlorides with FY15 DE08 showing the less amount of chlorides; (5) dye penetrant examination was performed on the interior and exterior surfaces of all the sidewall sections but reveled no relevant indication of surface-breaking defects, (6) finally, as described above, the full circumference examination of the ICCWR by LCM was completed. The three ICCWRs show general and localized corrosion on the surface. However, FY15 DE08 show more areas with agglomerated pits in Zones 2 and 3 than the other two DEs. The major suspect corrosion events were observed for FY15 DE07 on Sections C1 and C2 and for FY15 DE08 on Section C2. These events correspond to suspect cracks or crack-like features identified with a unique name to easily refer to each feature. FY15 DE07 shows a crack-like feature, identified as Acrux, in Section C1 and three features in Section C2 identified as Bellatrix, Cursa Minor and Cursa Major. Acrux and Bellatrix are located at the boundary of Zone 2 and Zone 3. Cursa Minor and Cursa Major are in Zone 2. FY15 DE08 shows two crack-like features, identified as Denebola and Draco, in Section C2. Both features are located at the boundary of Zone 2 and Zone 3. However, gas analysis and statistical evaluation of the gas compositions and pressures via GEST analyses suggest that leakage between the OI and IC volumes was unlikely. Additional characterization and analysis will be performed on the locations where the cracks were found.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summary of Assessments Performed in FY 20 by SNL QA POC for FY 19 SNL NTRD Milestone Deliverables

The Sandia National Laboratories (SNL) staff is meeting the requirements of Nuclear Fuel Cycle and Supply Chain (NFCSC) Quality Assurance Program Document (QAPD). Each of the NFCSC FY 19 packages for SNL were reviewed. Minor errors were identified with regard to one package for the previous version of this report. Those are being rectified and future instances will indicate the appropriate entries. Aside from the minor discrepancies noted, there were no quality assurance findings this fiscal year for the NFCSC program. In particular, all of the Quality Rigor Level (QRL) level assignments were confirmed to be appropriate.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Status of the Characterization of DEs from the Full Circumference Examination of the Inner Container Closure Weld Region (FY2020)

One of the main focus areas of the 3013 Surveillance Program is a thorough evaluation of the inner container closure weld region (ICCWR) opened for destructive examination (DE). As part of the protocol to investigate the corrosion in the ICCWR a laser confocal microscope (LCM) is used to perform close visual examination of the surface and measurements of corrosion features on the surface. DE containers from FY13 through FY16 were screened with three candidates selected for full circumference evaluation (FCE) according to the ICCWR examination protocol, During the FCE, FY16 DE05 and FY15 DE07 showed suspect major corrosion events, FY16 DE05 Section C2 shows two crack-like features, identified as Denebola and Draco. Both features are located at the boundary of Zone 2 and Zone 3. Consequently, Section C2 of FY16 DE05 was selected for examination by serial metallography at Savannah River National Laboratory (SRNL). For FY15 DE07 the suspect corrosion events were observed on Sections Cl and C2. Section Cl shows one crack-like feature, identified as Acrux. Section C2 shows three crack-like features, identified as Bellatrix, Cursa Minor and Cursa Major. Unlike Acrux and Bellatrix, which are located at the boundary of Zone 2 and Zone 3, Cursa Minor and Cursa Major are located in Zone 2. Sections Cl and C2 of FY15 DE07 were sent to Los Alamos National Laboratory (LANE) for characterization by X-Ray Tomography (XRT).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vitrification of Hanford Tank 241-AP-107 with Recycled Condensate

During the vitrification of nuclear waste at the Hanford Waste Treatment and Immobilization Plant (WTP) – the primary mission of the U.S. Department of Energy Office of River Protection – the offgas condensate generated from the waste-to-glass conversion is currently planned to be concentrated by evaporation in the Effluent Management Facility (EMF). This concentrated condensate can then be recycled back to the incoming waste and vitrified. To test the recycle process, a test apparatus was designed to mimic the EMF evaporator and used to concentrate a volume of condensate that had been previously produced during the vitrification of Hanford tank 241-AP-107 (referred to herein as AP-107) waste in a continuous laboratory-scale melter (CLSM). The test apparatus successfully concentrated the AP-107 condensate by a factor of 10 while retaining over 90 % of the technetium-99 ( 99 Tc), Cs, and I inventory. A second portion of AP-107 waste was retrieved by Washington River Protection Solutions, LLC, given to Pacific Northwest National Laboratory, and combined with the AP-107 condensate concentrate after undergoing solids filtration and cesium removal by ion exchange. This combination served to approximate the recycling action to be performed at the WTP. After the addition of glass-forming chemicals (GFCs), the combined AP-107 waste and AP-107 condensate concentrate were processed in the CLSM to produce a glass, called AP-107-1R, that was designed to satisfy the WTP baseline requirements (Kim et al. 2012). During the 8.87 hours of processing, 7.27 kg of AP-107-1R glass were produced for an average glass production rate of 1739 kg m 2 d -1 . Compared to the previous run in the CLSM without recycled condensate, the run with the recycle had a greater average glass production rate, but the rate was within the potential range of variability when processing melter feeds with similar composition in the CLSM. The glass produced from the AP-107 recycle run in the CLSM was within 10 % of the target AP-107-1R glass composition with respect to the primary glass components. Analysis of the minor component impurities revealed that their content in the glass product had approached their nominal target after 2 turnovers of the glass inventory in the CLSM while the activity of the minor radionuclides was retained in the glass product. The 99 Tc and total cesium content in the combined AP-107 waste and recycled condensate were maintained at concentrations expected to be experienced at the WTP. During processing in the CLSM, at discrete sampling time periods, the target 99 Tc/Cs mass ratio in the glass formulation varied from 0.9 to 62.9. Across this range, the Cs retention in the glass ranged from 53 to 60 %, while the retention from the entire runtime totaled 68 %, values which align with Cs retention in other scaled melter systems while processing LAW melter feeds at 99 Tc/Cs mass ratios ranging from 1 to 100. The 99 Tc retention in the glass ranged from 22 to 32 %, primarily due to the cold-cap coverage on the glass melt surface, the area covered by reacting melter feed, varying from ~80 % to ~95 % during processing, demonstrating greater volatility of 99 Tc from the glass while more surface was exposed, as expected based on previous 99 Tc volatility studies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of K-Optimization on Trap Concentration in (Ag,Cu)(In,Ga)Se 2 Solar Cells

Recent progress has been made in improving efficiency in Cu(In,Ga)Se 2 (CIGS) absorbers with steady increases in peak efficiency. One way this has been achieved is by adding Ag to CIGS (ACIGS) to achieve higher V OC . However, these efficiencies are still well below the Shockley-Queisser efficiency limit, and traps acting as recombination centers and compensating centers are one thing limiting the solar efficiency. Past research in CIGS has shown that alkali treatment can improve the efficiency and metastability problems in CIGS, but less is understood about the role of alkali treatments in ACIGS. Here, we investigate the impact of potassium in ACIGS through its impact on trap incorporation and minority carrier lifetime. The samples in this study were grown in a roll-to-roll coater with Mo, ACIGS, CdS, and ZnO structure. Both cells were grown identically except the second (K-optimized) cell was grown with increased K-doping of the Mo contact and was more Cu-poor near the surface to optimize the K profile. This resulted in an efficiency increase from 16.8% to 18.7% for the K-optimized cell, which was mostly due to a 65 mV V OC increase. The doping profile showed a 2X increase in acceptor concentration of the K-optimized cell (2.5×10 15 cm -3 ) which suggests that the K was better incorporated into the ACIGS after these optimizations. To characterize the traps in these cells, deep level transient and optical spectroscopy were used. The DLOS measurements showed an EV+0.98 eV trap whose concentration was reduced 10X in the K-optimized cell (4×10 14 cm -3 ). This is consistent with previous results from the alkali treatment in CIGS, which also showed a decrease in near-conduction band trap concentration [1], but the reduction was larger than previous studies possibly indicating the combination of K and Cu-poor surface may both have aided in reducing the EV+0.98 eV trap concentration. The other primary trap is the mid-gap trap (EV+0.58 eV), which was quantified using DLTS. Its concentration decreased from 9×10 13 cm -3 to 4×10 13 cm -3 in the K-optimized sample, which is a 2X reduction. Previous studies have shown this trap is likely an efficient recombination center [2], which makes sense because it is near mid-gap. This trap has also been associated with V OC instability and reduction, so reducing this trap concentration is essential to achieve high V OC and cell efficiency. To help confirm this association, time-resolved photoluminescence measurements have shown in this sample set and a previous study that the minority carrier lifetime (19 ns baseline to 56 ns K-optimized) and this EV+0.56 eV trap concentration are inversely proportional, which would be expected for a recombination-limited carrier lifetime. The K optimization of ACIGS results in significantly improved cell efficiency and reduced trap concentrations that correlate with the improved material and electrical properties. We will report on this and the impact of the K optimization on the cell metastability.

14 SOLAR ENERGY↗

Laser-Interference Surface Preparation for Enhanced Coating Adhesion and Adhesive Joining of Multi-Materials (Final Project Report)

This report investigates a laser-interference surface treatment as a non-contact, i.e., without major solid/liquid medium application or abrasion, and non-chemical surface preparation method for aerospace coating systems. It was proposed to use the laser-interference technique to structure surfaces of Al and/or Ti, creating "rough" surfaces with pre-engineered series of ridges and valleys at submicron scale. The science goal of this study was to develop an understanding of the surface microstructure, topology, and physical mechanisms that would improve adhesion and corrosion protection of Al2024-T3. Microstructure analysis indicates that the laser-interference structuring (LIS) was found to reduce the formation of CuMn-rich precipitates in Al 2024-T3 over a 500-800 nm depth from top surface. The X-cut and cross-hatch coating adhesion ratings indicate that the LIS specimens meet the performance requirements in the coating adhesion specifications by having a higher or identical ranking to those specimens prepared with current state-of-the-art chemical conversion or sulfuric acid anodizing. After the ASTM B117 corrosion exposure, it was found that the laser processed specimens exhibited only few blisters. It was found that the corrosion damage was minimized at a laser rastering speed of 4 mm/s, for which only 33% of specimens developed very minor corrosion damage. The ASTM D1654 creepage ratings, used to evaluate corrosion damage along the scribe lines, were found to be at least nine for all coated panels. These results indicate that the laser-interference technique with the additional acetone wiping has the potential to be further developed as a minor chemical surface preparation technique for chromate-containing epoxy primers coatings.

36 MATERIALS SCIENCE↗

Tunable Laser-Plasma Amplifier (Final Report)

Exploration at the laser intensity frontier has always offered new avenues for physics and reaching beyond this frontier is a grand challenge. Present-day petawatt-class lasers provide focused intensities on target of 10 22 W/cm 2 , corresponding to electric fields of 200 TV/m, while laser-plasma amplification opens a route for focused intensities well above 10 23 W/cm 2 . Intensities in this range provide the ability to test quantum electrodynamics in the unexplored low-energy, strong-field regime where signatures for new physics may arise. The behavior of matter under such extraordinary conditions is a rich and fascinating subject, not only in its own right in fundamental plasma physics, but for the many potential applications that promise to enrich the natural sciences in the future, including compact electron-beam, ion-beam particle accelerators, and ultra-bright X-ray sources. Although laser systems are now under construction internationally to access intensities of 10 23 W/cm 2 , the current technologies used appear to be fundamentally limited to these intensities. The realization of intensities beyond 10 23 W/cm 2 using parametric amplification in plasmas promises a breakthrough in high-energy density physics. Parametric amplification using Raman scattering in a plasma could provide the enabling technology for the generation of ultra-high-power laser pulses, but a more complete understanding of the nonlinear optics of plasmas is required. There is a significant gap in well-diagnosed laser-plasma instability studies of nonlinear plasma-wave phenomena, which are critical to understand for future laser-plasma devices. To achieve an efficient laser-plasma amplifier, plasma waves must be driven to large amplitude where significant energy can be rapidly transferred from the pump to the seed over the pulse duration of the seed. Simulations suggest that this nonlinear pump depletion regime can be achieved in the “pi-pulse” amplification regime. While simulations show this optimal regime with efficient amplification, it has remained elusive in experiments and there is a growing consensus within the community that thermal effects and pump beam limitations prevent laser-plasma amplifiers from progressing through the linear regime into the nonlinear pump depletion regime. Previous experiments have been significantly limited by the laser power available at the necessary wavelengths for the seed laser; therefore, the amplification is required to start in the linear regime where it is sensitive to many deleterious effects. The enabling technology (currently unique to plasma-wave amplification in the world) at the University of Rochester is the ability to provide a seed pulse with sufficient power (4 mJ/100 fs seed) to immediately drive nonlinear plasma waves into the pi-pulse regime and to tune its wavelength to optimize the efficiency of energy transfer. This in combination with the state-of-the-art OMEGA heater beams providing multiple kilojoules in a nanosecond to sufficiently heat the plasma make this system distinct from previous studies. These heater beams will provide, for the first time in Raman amplification studies, a homogeneous electron temperature high enough to prevent pump beam propagation issues that have plagued previous experiments. These systems will provide a platform for driving electron-plasma waves into the nonlinear regime where pump depletion and pulse shortening are predicted to lead to high amplification efficiencies (>30%). The Team has made significant progress through prior support from DOE Fusion Energy Sciences [DOE Office of Science Award Number DE-SC0016253 (2016-2022)]. This includes twenty-two peer-reviewed manuscripts, one patent, ten contributed talks presented at international conferences, and research that was highlighted as invited talks at fifteen international conferences. The broader impacts of this research are evident in the support of early career scientists, two Ph.D. theses, four current graduate students, a Masters Project, two undergraduate researchers, and an underrepresented minority student hired through the California Alliance for Minority Participation who now works as a Research Engineer in the group. This research met all of the funded research objectives and the highlights from primary Raman amplification thrust of this work are discussed below and form the foundation for the proposed research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗