Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Implementation of Monte Carlo Transport in the General Relativistic SpEC Code

Neutrino transport and neutrino-matter interactions are known to play an important role in the evolution of neutron star mergers and of their post-merger remnants. Neutrinos cool remnants, drive post-merger winds, and deposit energy in the low-density polar regions where relativistic jets may eventually form. Neutrinos also modify the composition of the ejected material, impacting the outcome of nucleosynthesis in merger outflows and the properties of the optical/infrared transients that they power (kilonovae). So far, merger simulations have largely relied on approximate treatments of the neutrinos (leakage, moments) that simplify the equations of radiation transport in a way that makes simulations more affordable but also introduces unquantifiable errors in the results. To improve on these methods, we recently published a first simulation of neutron star mergers using a low-cost Monte Carlo algorithm for neutrino radiation transport. Our transport code limits costs in optically thick regions by placing a hard ceiling on the value of the absorption opacity of the fluid, yet all approximations made within the code are designed to vanish in the limit of infinite numerical resolution. We provide here an in-depth description of this algorithm, of its implementation in the SpEC merger code, and of the expected impact of our approximations in optically thick regions. We argue that the last is a subdominant source of error at the accuracy reached by current simulations and for the interactions currently included in our code. We also provide tests of the most important features of this code.

79 ASTRONOMY AND ASTROPHYSICS↗

MCNP® Code Version 6.3.1 Release Notes

The Monte Carlo N-Particle® (MCNP® ) code is a general-purpose, continuous-energy, generalized-geometry, time-dependent, radiation transport code developed by the MCNP development team. MCNP calculations provide predictive capabilities that can replace expensive or impossible-to-perform experiments. Specific application problems include simulations of experimental diagnostics, intrinsic radiation, radiation detection and measurement, criticality safety, nuclear threat reduction and response, radiation health protection, nuclear weapons effects, and nuclear forensics. This MCNP code, version 6.3.1, follows the MCNP6.3.0 version. Since the release of MCNP6.3.0, a variety of bug fixes and code enhancements have been completed for MCNP6.3.1. A few new features have also been added to this release to support both ongoing research and the release of the latest ENDF/B-VIII.1 nuclear data library. The MCNP code, version 6.3.1, theory and user input information is documented in MCNP® Code Version 6.3.1 Theory & User Manual, the build guidance for various platforms is documented in MCNP® Code Version 6.3.1 Build Guide, and the verification and validation testing for various application benchmark test suites is documented in MCNP® Code Version 6.3.1 Verification & Validation Testing.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using Whisper-1.1 to guide improvements to nuclear data evaluations

Along with the latest release of the general purpose Monte Carlo radiation transport code, MCNP6.2, came the first officially released version of Whisper, version 1.1, a statistical analysis code used for nuclear criticality safety (NCS) validation. The Whisper software package is primarily used to calculate the upper subcritical limit (USL) of a particular application case along with components of the margin of subcriticality (MOS). In the calculation of the MOS due to nuclear data uncertainties, Whisper uses the generalized linear-least-squares (GLLS) approach to obtain adjusted nuclear data uncertainties which are then propagated to estimate the nuclear data uncertainties in the k{sub eff} of the application. Due to the fact that Whisper contains the simulated and measured k{sub eff} values for over 1100 benchmarks, nuclear data sensitivity profiles for each benchmark along with the nuclear data covariance matrices, all of which are used in the GLLS method, it is possible to easily utilize these data available to help guide improvements to nuclear data evaluations. In the present work, the Whisper data and the GLLS method are used together to suggest an adjusted nuclear data cross section evaluation specifically for {sup 233}U such that the agreement between the calculated and experimental k{sub eff} measurements of the relevant benchmarks are improved. With this adjusted nuclear data available, feedback to the theoretical and experimental nuclear data community is provided. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

(U) A Code System for Cross-Section Uncertainty Propagation for PARTISN

A rudimentary code system has been developed for propagating neutron cross-section uncertainties to response uncertainties using the PARTISN multigroup discrete-ordinates neutron transport code. The code system uses the first-order sandwich rule with sensitivities computed using SENSMG and covariances computed using NJOY. Databases of reaction cross sections and covariances using ENDF/B-VIII.0 data in the LANL standard 30-group structure have been precalculated. The final uncertainty in a k eff example problem compares well with the result from TOFFEE, a similar code that propagates neutron cross-section uncertainties to response uncertainties using the MCNP6 Monte Carlo neutron transport code. Presently, neither code system propagates uncertainties in $\overline{v}$, $\overline{μ}$, or χ, and neither code system propagates nuclide-nuclide covariances

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benchmarking PARTISN with Analog Monte Carlo: Moments of the Neutron Number and the Cumulative Fission Number Probability Distributions

The purpose of this report is to provide the reader with an understanding of how a Monte Carlo neutron transport code was written, developed, and evolved to calculate the probability distribution functions (PDFs) and their moments for the neutron number at a final time as well as the cumulative fission number, along with introducing several basic Monte Carlo concepts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coupling External Radiation Transport Code Results to the GADRAS Detector Response Function

Simulating gamma spectra is useful for analyzing special nuclear materials. Gamma spectra are influenced not only by the source and the detector, but also by the external, and potentially complex, scattering environment. The scattering environment can make accurate representations of gamma spectra difficult to obtain. By coupling the Monte Carlo Nuclear Particle (MCNP) code with the Gamma Detector Response and Analysis Software (GADRAS) detector response function, gamma spectrum simulations can be computed with a high degree of fidelity even in the presence of a complex scattering environment. Traditionally, GADRAS represents the external scattering environment with empirically derived scattering parameters. By modeling the external scattering environment in MCNP and using the results as input for the GADRAS detector response function, gamma spectra can be obtained with a high degree of fidelity. This method was verified with experimental data obtained in an environment with a significant amount of scattering material. The experiment used both gamma-emitting sources and moderated and bare neutron-emitting sources. The sources were modeled using GADRAS and MCNP in the presence of the external scattering environment, producing accurate representations of the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new cubic phantom for PET/CT dosimetry: Experimental and Monte Carlo characterization

In recent years, positron emission tomography (PET) associated with multidetector computed tomography (MDCT) has become a diagnostic technique widely disseminated to evaluate various malignant tumors and other diseases. However, during PET/CT examinations, the doses of ionizing radiation experienced by the internal organs of patients may be substantial. To study the doses involved in PET/CT procedures, a new cubic phantom of overlapping acrylic plates was developed and characterized. This phantom has a deposit for the placement of the fluorine-18 fluoro-2-deoxy-D-glucose ({sup 18}F-FDG) solution. There are also small holes near the faces for the insertion of optically stimulated luminescence dosimeters (OSLD). The holes for OSLD are positioned at different distances from the {sup 18}F-FDG deposit. The experimental results were obtained in two PET/CT devices operating with different parameters. Differences in the absorbed doses were observed in OSLD measurements due to the non-orthogonal positioning of the detectors inside the phantom. This phantom was also evaluated using Monte Carlo simulations, with the MCNPX code. The phantom and the geometrical characteristics of the equipment were carefully modeled in the MCNPX code, in order to develop a new methodology form comparison of experimental and simulated results, as well as to allow the characterization of PET/CT equipments in Monte Carlo simulations. All results showed good agreement, proving that this new phantom may be applied for these experiments. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of the VERA Core Physics Benchmark Problems using cosRMC Code

In reactor physics, two kinds of numerical methods are generally employed to solve the neutron transport equations, one of which is the deterministic method and the other one is the Monte Carlo method. Monte Carlo is widely used to provide reference solution because of its ability to deal with continuous energy cross sections and complex geometry. Just like any statistical process, the Monte Carlo method requires repetition to achieve a small relative uncertainty, and therefore may inevitably have larger simulation times than deterministic method. Fortunately, the great advancements of computer technology make it possible to apply Monte Carlo method in reactor core analysis. To promote nuclear power plant system design and simulation software self-reliance development, a Monte Carlo neutron/photon transport code cosRMC has been developed jointly by State Nuclear Power Software Development Center (SNPSDC) and Tsinghua University. The cosRMC is aimed at achieving full core calculations and analysis with high fidelity and efficiency by means of advanced methodologies and algorithms as well as high performance computing techniques. The cosRMC has many functions as criticality calculation, fixed-source calculation, burnup calculation, etc. In order to ensure its reliability, several types of verification and validation (V and V) work have been and are being carried out for cosRMC. The simulation results of cosRMC based on Problem 1 to 3 of VERA Core Physics Benchmark showed its good capability of 2D lattice and 3D assembly modeling. In this paper, some progressive verification results of multi-assembly and full core problems are presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

General Relativistic Implicit Monte Carlo Radiation-hydrodynamics

Abstract We report on a new capability added to our general relativistic radiation-magnetohydrodynamics code, Cosmos++ : an implicit Monte Carlo (IMC) treatment for radiation transport. The method is based on a Fleck-type implicit discretization of the radiation-hydrodynamics equations, but generalized for both Newtonian and relativistic regimes. A multiple reference frame approach is used to geodesically transport photon packets (and solve the hydrodynamics equations) in the coordinate frame, while radiation–matter interactions are handled either in the fluid or electron frames then communicated via Lorentz boosts and orthonormal tetrad bases attached to the fluid. We describe a method for constructing estimators of radiation moments using path-weighting that generalizes to arbitrary coordinate systems in flat or curved spacetime. Absorption, emission, scattering, and relativistic Comptonization are among the matter interactions considered in this report. We discuss our formulations and numerical methods, and validate our models against a suite of radiation and coupled radiation-hydrodynamics test problems in both flat and curved spacetimes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear signal simulation applied to gas ionizing chambers

Particle transport codes used in detector simulation allow the calculation of the energy deposited by charged particles produced following an interaction. The pulses temporal shaping is more and more used in nuclear measurement into pulse shape analysis techniques. A model is proposed in this paper to simulate the pulse temporal shaping and the associated noise level thanks to the output track file PTRAC provides by Monte-Carlo particle transport codes. The model has been dedicated to ion chambers and more especially for High Pressure Xenon chambers HPXe where the pulse shape analysis can resolve some issues regarding with this technology as the ballistic deficit phenomenon. The model is fully described and an example is presented as a validation of such full detector simulation. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NUMERICAL MODELING OF MULTI-WAVELENGTH SPECTRA OF M87 CORE EMISSION

Spectral fits to M87 core data from radio to hard X-ray are generated via a specially selected software suite, comprised of the High-Accuracy Relativistic Magnetohydrodynamics GRMHD accretion disk model and a two-dimensional Monte Carlo radiation transport code. By determining appropriate parameter changes necessary to fit X-ray-quiescent and flaring behavior of M87's core, we assess the reasonableness of various flaring mechanisms. This shows that an accretion disk model of M87's core out to 28 GM/c{sup 2} can describe the inner emissions. High spin rates show GRMHD-driven polar outflow generation, without citing an external jet model. Our results favor accretion rate changes as the dominant mechanism of X-ray flux and index changes, with variations in density of approximately 20% necessary to scale between the average X-ray spectrum and flaring or quiescent spectra. The best-fit parameters are black hole spin a/M > 0.8 and maximum accretion flow density n {<=} 3 Multiplication-Sign 10{sup 7} cm{sup -3}, equivalent to horizon accretion rates between m-dot = M-dot / M-dot{sub Edd}{approx}2 Multiplication-Sign 10{sup -6} and 1 Multiplication-Sign 10{sup -5} (with M-dot{sub Edd} defined assuming a radiative efficiency {eta} = 0.1). These results demonstrate that the immediate surroundings of M87's core are appropriate to explain observed X-ray variability.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimization of a coupling scheme between MCNP5 and SUBCHANFLOW for high fidelity modeling of LWR reactors

In order to increase the accuracy and the degree of spatial resolution of core design studies, coupled Three-Dimensional (3D) neutronics (deterministic and Monte Carlo) and 3D thermal hydraulics (CFD and sub-channel) codes are being developed worldwide. In this paper the optimization of a coupling between MCNP5 code and an in-house development thermal-hydraulics code SUBCHANFLOW is presented. Various improvements of the coupling methodology are presented. With the help of novel interpolation tool a consistent methodology for the preparation of thermal scattering data library have been developed, ensuring that inelastic scattering from bound nuclei is treated at the correct moderator temperature. Trough the utilization of a hybrid coupling with discrete energy Monte-Carlo code KENO a methodology for acceleration of the coupled calculation is being demonstrated. In this approach an additional coupling between KENO and SUBCHANFLOW was developed, the converged results of which are used as initial conditions for the MCNP-SUBCHANFLOW coupling. Acceleration of fission source distribution convergence, by sampling fission source distribution from the power distribution obtained by KENO is also demonstrated. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

LLNL Mercury Project Trinity Open Science Final Report

The Mercury Monte Carlo particle transport code developed at Lawrence Livermore National Laboratory (LLNL) is used to simulate the transport of radiation through urban environments. These challenging calculations include complicated geometries and require significant computational resources to complete. As a result, a question arises as to the level of convergence of the calculations with Monte Carlo simulation particle count. In the Trinity Open Science calculations, one main focus was to investigate convergence of the relevant simulation quantities with Monte Carlo particle count to assess the current simulation methodology. Both for this application space but also of more general applicability, we also investigated the impact of code algorithms on parallel scaling on the Trinity machine as well as the utilization of the Trinity DataWarp burst buffer technology in Mercury via the LLNL Scalable Checkpoint/Restart (SCR) library.

54 ENVIRONMENTAL SCIENCES↗

Radiation shielding for superconducting RF cavity test facility at A0

The results of Monte Carlo radiation shielding study performed with the MARS15 code for the vertical test facility at the A0 north cave enclosure at Fermilab are presented and discussed. The vertical test facility at the A0 north cave is planned to be used for testing 1.3 GHz single-cell superconducting RF cavities with accelerating length of 0.115 m. The operations will be focused on high accelerating gradients--up to 50 MV/m. In such a case the facility can be a strong radiation source [1]. When performing a radiation shielding design for the facility one has to take into account gammas generated due to interactions of accelerated electrons with cavity walls and surroundings (for example, range of 3.7-MeV electrons in niobium is approximately 3.1 mm while the thickness of the niobium walls of such RF cavities is about 2.8 mm). The electrons are usually the result of contamination in the cavity. The radiation shielding study was performed with the MARS15 Monte Carlo code [2]. A realistic model of the source term has been used that describes spatial, energy and angular distributions of the field-emitted electrons inside the RF cavities. The results of the calculations are normalized using the existing experimental data on measured dose rate in the vicinity of such RF cavities.

43 PARTICLE ACCELERATORS↗

An EGSnrc Monte Carlo-calculated database of TG-43 parameters

Monte Carlo methods are used to calculate a complete TG-43 dosimetry parameter data set for 27 low-energy photon emitting brachytherapy sources (18 {sup 125}I and 9 {sup 103}Pd). All Monte Carlo calculations are performed using the EGSnrc user-code BrachyDose. TG-43 dosimetry parameters, including dose rate constants, radial dose functions (with functional fitting parameters), and anisotropy data, are calculated with finer spatial resolution, greater range of distances, and smaller uncertainties than data currently available in the literature for many of these sources. In particular, for most of the seeds, this is the first time that anisotropy data have been tabulated at distances less than 0.5 cm from the source. These calculations employ the state-of-the-art XCOM photon cross sections, and detailed source geometries are modeled using Yegin's multigeometry package. This data set serves as a completely independent verification of the currently available dosimetry parameters calculated using other Monte Carlo codes, including MCNP and PTRAN. This report also describes the Carleton Laboratory for Radiotherapy Physics TG-43 Parameter Database, a publicly accessible web site (at http://www.physics.carleton.ca/clrp/seed{sub d}atabase/) through which all of the data calculated for this study can be accessed. Also available on the web site are descriptions of the methods and Monte Carlo models used in this study and comparisons of data calculated in this study with data calculated by other authors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Applications of the Monte Carlo method in nuclear physics using the GEANT4 toolkit

The capabilities of the personal computers allow the application of Monte Carlo methods to simulate very complex problems that involve the transport of particles through matter. Among the several codes commonly employed in nuclear physics problems, the GEANT4 has received great attention in the last years, mainly due to its flexibility and possibility to be improved by the users. Differently from other Monte Carlo codes, GEANT4 is a toolkit written in object oriented language (C++) that includes the mathematical engine of several physical processes, which are suitable to be employed in the transport of practically all types of particles and heavy ions. GEANT4 has also several tools to define materials, geometry, sources of radiation, beams of particles, electromagnetic fields, and graphical visualization of the experimental setup. After a brief description of the GEANT4 toolkit, this presentation reports investigations carried out by our group that involve simulations in the areas of dosimetry, nuclear instrumentation and medical physics. The physical processes available for photons, electrons, positrons and heavy ions were used in these simulations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Physics and Algorithm Enhancements for a Validated MCNP/X Monte Carlo Simulation Tool, Phase VII

Currently the US lacks an end-to-end (i.e., source-to-detector) radiation transport simulation code with predictive capability for the broad range of DHS nuclear material detection applications. For example, gaps in the physics, along with inadequate analysis algorithms, make it difficult for Monte Carlo simulations to provide a comprehensive evaluation, design, and optimization of proposed interrogation systems. With the development and implementation of several key physics and algorithm enhancements, along with needed improvements in evaluated data and benchmark measurements, the MCNP/X Monte Carlo codes will provide designers, operators, and systems analysts with a validated tool for developing state-of-the-art active and passive detection systems. This project is currently in its seventh year (Phase VII). This presentation will review thirty enhancements that have been implemented in MCNPX over the last 3 years and were included in the 2011 release of version 2.7.0. These improvements include 12 physics enhancements, 4 source enhancements, 8 tally enhancements, and 6 other enhancements. Examples and results will be provided for each of these features. The presentation will also discuss the eight enhancements that will be migrated into MCNP6 over the upcoming year.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of SERPENT and CASMO-5M for pressurized water reactors models

The objective of this work is to perform a preliminary assessment of the capability of SERPENT to generate cross sections for a PWR Beginning-of-Life (BOL) isothermal mini-core by comparing a SERPENT/PARCS solution with the results obtained using a CASMO-5M/PARCS approach. The PARCS code is used instead of the usual SIMULATE-3 to analyze the Swiss Reactors, because interfaces with PARCS already exist to obtain neutronic data from SERPENT. For the PWR configurations, the differences between CASMO-5M and SERPENT solutions are within 200 pcm at the assembly level and thus rather small when considering the deterministic transport method (energy/angular/space discretization) in CASMO-5M versus the stochastic treatment of SERPENT, the statistical uncertainties in the Monte-Carlo approach as well as the eventual differences in nuclear data used by both codes. At the 2D mini-core level, no major difference is observed when comparing PARCS run with CASMO-5M versus SERPENT cross sections. For the generation of kinetic parameters, non trivial differences are observed due both to the methods and the data used. For the relatively limited number of configurations considered, it is hard to make any definitive statement on the benefits of using Monte Carlo codes in terms of nuclear data generation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗