Design of High Temperature Ultrasonic Linear Arrays for Under-Sodium Viewing

This paper summarizes the design process for high temperature ultrasonic phased array transducers for imaging in liquid sodium at temperatures up to 260C. The project is funded by the USDOE Generation IV Reactor Program and includes collaboration with the Japanese Atomic Energy Agency. The transducer system is being designed to be able to provide images inside a sodium cooled fast reactor, to support operation and maintenance activities including potentially location of looseor damaged parts during service outages. The prototype transducer array is being designed for 8 to 16, 3MHz rectangular lead niobate (K-81) or bismuth titanate (K-15) piezoelectric elements spaced at λ/2 (wavelength in sodium). A nickel or nickel alloy faceplate serves as the sodium wetting surface. Scan angle of the focused ultrasonic beam is ±30 degrees. Imaging spatial resolution is ≤ 1mm. The array is designed to be operated using a commercial phased array control system and it is planned that array testing will be performed in room temperature water, hot oil (260C), and molten sodium (260C).

liquid metal fast reactor↗

Sub-aperture piston phase diversity for segmented and multi-aperture systems

Phase diversity is a method of image-based wavefront sensing that simultaneously estimates the unknown phase aberrations of an imaging system along with an image of the object. To perform this estimation a series of images differing by a known aberration, typically defocus, are used. In this paper we present a new method of introducing the diversity unique to segmented and multi-aperture systems in which individual segments or sub-apertures are pistoned with respect to one another. We compare this new diversity with the conventional focus diversity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Robust optimization methods for cardiac sparing in tangential breast IMRT

Purpose: In left-sided tangential breast intensity modulated radiation therapy (IMRT), the heart may enter the radiation field and receive excessive radiation while the patient is breathing. The patient’s breathing pattern is often irregular and unpredictable. We verify the clinical applicability of a heart-sparing robust optimization approach for breast IMRT. We compare robust optimized plans with clinical plans at free-breathing and clinical plans at deep inspiration breath-hold (DIBH) using active breathing control (ABC). Methods: Eight patients were included in the study with each patient simulated using 4D-CT. The 4D-CT image acquisition generated ten breathing phase datasets. An average scan was constructed using all the phase datasets. Two of the eight patients were also imaged at breath-hold using ABC. The 4D-CT datasets were used to calculate the accumulated dose for robust optimized and clinical plans based on deformable registration. We generated a set of simulated breathing probability mass functions, which represent the fraction of time patients spend in different breathing phases. The robust optimization method was applied to each patient using a set of dose-influence matrices extracted from the 4D-CT data and a model of the breathing motion uncertainty. The goal of the optimization models was to minimize the dose to the heart while ensuring dose constraints on the target were achieved under breathing motion uncertainty. Results: Robust optimized plans were improved or equivalent to the clinical plans in terms of heart sparing for all patients studied. The robust method reduced the accumulated heart dose (D10cc) by up to 801 cGy compared to the clinical method while also improving the coverage of the accumulated whole breast target volume. On average, the robust method reduced the heart dose (D10cc) by 364 cGy and improved the optBreast dose (D99%) by 477 cGy. In addition, the robust method had smaller deviations from the planned dose to the accumulated dose. The deviation of the accumulated dose from the planned dose for the optBreast (D99%) was 12 cGy for robust versus 445 cGy for clinical. The deviation for the heart (D10cc) was 41 cGy for robust and 320 cGy for clinical. Conclusions: The robust optimization approach can reduce heart dose compared to the clinical method at free-breathing and can potentially reduce the need for breath-hold techniques.

60 APPLIED LIFE SCIENCES↗

SU-E-J-226: Propagation of Pancreas Target Contours On Respiratory Correlated CT Images Using Deformable Image Registration

Purpose: Respiratory Correlated CT (RCCT) scans to assess intra-fraction motion among pancreatic cancer patients undergoing radiotherapy allow for dose sparing of normal tissues, in particular for the duodenum. Contour propagation of the gross tumor volume (GTV) from one reference respiratory phase to 9 other phases is time consuming. Deformable image registration (DIR) has been successfully used for high contrast disease sites but lower contrast for pancreatic tumors may compromise accuracy. This study evaluates the accuracy of Fast Free Form (FFF) registration-based contour propagation of the GTV on RCCT scans of pancreas cancer patients. Methods: Twenty-four pancreatic cancer patients were retrospectively studied; 20 had tumors in the pancreatic head/neck, 4 in the body/tail. Patients were simulated with RCCT and images were sorted into 10 respiratory phases. A radiation oncologist manually delineated the GTV for 5 phases (0%, 30%, 50%, 70% and 90%). The FFF algorithm was used to map deformations between the EE (50%) phase and each of the other 4 phases. The resultant deformation fields served to propagate GTV contours from EE to the other phases. The Dice Similarity Coefficient (DSC), which measures agreement between the DIR-propagated and manually-delineated GTVs, was used to quantitatively examine DIR accuracy. Results: Average DSC over all scans and patients is 0.82 and standard deviation is 0.09 (DSC range 0.97–0.57). For GTV volumes above and below the median volume of 20.2 cc, a Wilcoxon rank-sum test shows significantly different DSC (p=0.0000002). For the GTVs above the median volume, average +/− SD is 0.85 +/− 0.07; and for the GTVs below, the average +/− SD is 0.75 +/−0.08. Conclusion: For pancreatic tumors, the FFF DIR algorithm accurately propagated the GTV between the images in different phases of RCCT, with improved performance for larger tumors.

60 APPLIED LIFE SCIENCES↗

Itokawa's Opposition Surge seen by Hayabusa/AMICA

Using images acquired by the Hayabusa/AMICA instrument, along with Lederer et al.'s (2008) ground-based observations, we re-examine Itokawa's disk-integrated phase curve. The AMICA images provide critical opposition measurements (between 0.7deg - 9.3deg phase at 540 nm). Using Hapke's model (2012), we fit the updated phase curves at 5 different wavelengths. Preliminary modeling results show a range of porosity values commensurate with those in the literature (Ostro et al. 2004, Gundlach and Blum, 2012, Kiuchi and Nakamura 2014) based on an impact-generated grain size distribution function and grain size range evaluations from the AMICA data (Yano et al. 2006). This wide range on a global porosity is indicative of a highly variable porosity across the surface. The derived transport mean free path and the generally forward scattering nature of the global regolith are indicative of scattering centers (such as cracks, bubbles, and inclusions) that are small compared to the observational wavelengths. The derived regolith properties are compared with the imaging and sample analysis results, providing a test of the predictive capabilities of global disk-integrated measurements. This work suggests that the sub-pixel grain information could be extracted from the photometry, especially around opposition.

Dominque, D.↗

SU-F-J-158: Respiratory Motion Resolved, Self-Gated 4D-MRI Using Rotating Cartesian K-Space Sampling

Purpose: Dynamic MRI has been used to quantify respiratory motion of abdominal organs in radiation treatment planning. Many existing 4D-MRI methods based on 2D acquisitions suffer from limited slice resolution and additional stitching artifacts when evaluated in 3D{sup 1}. To address these issues, we developed a 4D-MRI (3D dynamic) technique with true 3D k-space encoding and respiratory motion self-gating. Methods: The 3D k-space was acquired using a Rotating Cartesian K-space (ROCK) pattern, where the Cartesian grid was reordered in a quasi-spiral fashion with each spiral arm rotated using golden angle{sup 2}. Each quasi-spiral arm started with the k-space center-line, which were used as self-gating{sup 3} signal for respiratory motion estimation. The acquired k-space data was then binned into 8 respiratory phases and the golden angle ensures a near-uniform k-space sampling in each phase. Finally, dynamic 3D images were reconstructed using the ESPIRiT technique{sup 4}. 4D-MRI was performed on 6 healthy volunteers, using the following parameters (bSSFP, Fat-Sat, TE/TR=2ms/4ms, matrix size=500×350×120, resolution=1×1×1.2mm, TA=5min, 8 respiratory phases). Supplemental 2D real-time images were acquired in 9 different planes. Dynamic locations of the diaphragm dome and left kidney were measured from both 4D and 2D images. The same protocol was also performed on a MRI-compatible motion phantom where the motion was programmed with different amplitude (10–30mm) and frequency (3–10/min). Results: High resolution 4D-MRI were obtained successfully in 5 minutes. Quantitative motion measurements from 4D-MRI agree with the ones from 2D CINE (<5% error). The 4D images are free of the stitching artifacts and their near-isotropic resolution facilitates 3D visualization and segmentation of abdominal organs such as the liver, kidney and pancreas. Conclusion: Our preliminary studies demonstrated a novel ROCK 4D-MRI technique with true 3D k-space encoding and respiratory motion self-gating. The technique leads to high-resolution and artifacts-free 4D images for improved abdominal organ motion studies. K.S acknowledges funding support from NIH R01CA188300.

60 APPLIED LIFE SCIENCES↗

Visualizing bleb mass dynamics in single cells using quantitative phase microscopy

Understanding biological responses to directed energy (DE) is critical to ensure the safety of personnel within the Department of Defense. At the Air Force Research Laboratory, we have developed or adapted advanced optical imaging systems that quantify biophysical responses to DE. One notable cellular response to DE exposure is the formation of blebs, or semi-spherical protrusions of the plasma membrane in living cells. In this work, we demonstrate the capacity of quantitative phase imaging (QPI) to both visualize and quantify the formation of membrane blebs following DE exposure. QPI is an interferometric imaging tool that uses optical path length as a label-free contrast mechanism and is sensitive to the non-aqueous mass density, or dry mass, of living cells. Blebs from both CHO-K1 and U937 cells were generated after exposure to a series of 600 ns, 21.2 kV/cm electric pulses. These blebs were visualized in real time, and their dry mass relative to the rest of the cell body was quantified as a function of time. It is our hope that this system will lead to an improved understanding of both DE-induced and apoptotic blebbing.

Steelman, Zachary A.↗

Geometric ortho-rectification and generation of sigma(0) image products from multiple incidence synthetic aperture radar images

The results of the first phase of a cooperative effort in geometric orthorectification and generation of sigma(0) images of multiple incidence SAR images are presented. The geometric accuracy of the final image products is approximately 18 m or 1.5 pixels. A method for registering radar imagery collected from an airborne platform to an existing digital elevation model despite the effects of unmodeled variations in the flight path of the platform is demonstrated. The results indicate the requirements for a more detailed digital elevation model.

Curlander, James↗

Topography estimation with interferometric synthetic aperture radar using fringe detection

Methods are presented for using Synthetic Aperture Radar (SAR) interferometry data to estimate surface topography. An expression is given to relate the elevation of a ground point to the phase difference of SAR images received from two spatially separated antennas. An iterative algorithm which solves for the position and elevation of each point in the image simultaneously is developed. One of the critical issues that determines the accuracy of the terrain mapping is the phase unwrapping. An approach to the problem by fringe line detection is proposed. The algorithms are tested with two Seasat SAR images of terrain near Yellowstone National Park. The resultant elevation map is compared with a USGS terrain elevation model. The error of the SAR elevation with respect to the digital terrain map is about 8.2 percent of the total terrain variation.

Lin, Qian↗

Denoised Wigner distribution deconvolution via low-rank matrix completion

Wigner distribution deconvolution (WDD) is a decades-old method for recovering phase from intensity measurements. Although the technique offers an elegant linear solution to the quadratic phase retrieval problem, it has seen limited adoption due to its high computational/memory requirements and the fact that the technique often exhibits high noise sensitivity. Here, we propose a method for noise suppression in WDD via low-rank noisy matrix completion. Our technique exploits the redundancy of an object’s phase space to denoise its WDD reconstruction. We show in model calculations that our technique outperforms other WDD algorithms as well as modern iterative methods for phase retrieval such as ptychography. Here, our results suggest that a class of phase retrieval techniques relying on regularized direct inversion of ptychographic datasets (instead of iterative reconstruction techniques) can provide accurate quantitative phase information in the presence of high levels of noise.

47 OTHER INSTRUMENTATION↗

Direct, Dynamic Measurement of Interfacial Area within Porous Media

Standard models of two-phase flow in porous media have been shown to exhibit several shortcomings that might be partially overcome with a recently developed model based on thermodynamic principles (Hassanizadeh and Gray, 1990). This alternative two-phase flow model contains a set of new and non-standard parameters, including specific interfacial area. By incorporating interfacial area production, destruction, and propagation into functional relationships that describe the capillary pressure and saturation, a more physical model has been developed. Niessner and Hassanizadeh (2008) have examined this model numerically and have shown that the model captures saturation hysteresis with drainage/imbibition cycles. Several static experimental studies have been performed to examine the validity of this new thermodynamically based approach; these allow the determination of static parameters of the model. To date, no experimental studies have obtained information about the dynamic parameters required for the model. A new experimental porous flow cell has been constructed using stereolithography to study two-phase flow phenomena (Crandall et al. 2008). A novel image analysis tool was developed for an examination of the evolution of flow patterns during displacement experiments (Crandall et al. 2009). This analysis tool enables the direct quantification of interfacial area between fluids by matching known geometrical properties of the constructed flow cell with locations identified as interfaces from images of flowing fluids. Numerous images were obtained from two-phase experiments within the flow cell. The dynamic evolution of the fluid distribution and the fluid-fluid interface locations were determined by analyzing these images. In this paper, we give a brief introduction to the thermodynamically based two-phase flow model, review the properties of the stereolithography flow cell, and show how the image analysis procedure has been used to obtain dynamic parameters for the numerical model. These parameters include production/destruction of interfacial area as a function of saturation and capillary pressure. Our preliminary results for primary drainage in porous media show that the specific interfacial area increased linearly with increasing gas saturation until breakthrough of the displacing gas into the exit manifold occurred.

54 ENVIRONMENTAL SCIENCES↗

Two-Phase Flow Simulations In a Natural Rock Fracture using the VOF Method

Standard models of two-phase flow in porous media have been shown to exhibit several shortcomings that might be partially overcome with a recently developed model based on thermodynamic principles (Hassanizadeh and Gray, 1990). This alternative two-phase flow model contains a set of new and non-standard parameters, including specific interfacial area. By incorporating interfacial area production, destruction, and propagation into functional relationships that describe the capillary pressure and saturation, a more physical model has been developed. Niessner and Hassanizadeh (2008) have examined this model numerically and have shown that the model captures saturation hysteresis with drainage/imbibition cycles. Several static experimental studies have been performed to examine the validity of this new thermodynamically based approach; these allow the determination of static parameters of the model. To date, no experimental studies have obtained information about the dynamic parameters required for the model. A new experimental porous flow cell has been constructed using stereolithography to study two-phase flow phenomena (Crandall et al. 2008). A novel image analysis tool was developed for an examination of the evolution of flow patterns during displacement experiments (Crandall et al. 2009). This analysis tool enables the direct quantification of interfacial area between fluids by matching known geometrical properties of the constructed flow cell with locations identified as interfaces from images of flowing fluids. Numerous images were obtained from two-phase experiments within the flow cell. The dynamic evolution of the fluid distribution and the fluid-fluid interface locations were determined by analyzing these images. In this paper, we give a brief introduction to the thermodynamically based two-phase flow model, review the properties of the stereolithography flow cell, and show how the image analysis procedure has been used to obtain dynamic parameters for the numerical model. These parameters include production/destruction of interfacial area as a function of saturation and capillary pressure. Our preliminary results for primary drainage in porous media show that the specific interfacial area increased linearly with increasing gas saturation until breakthrough of the displacing gas into the exit manifold occurred.

54 ENVIRONMENTAL SCIENCES↗

LIVA: A Data Reduction Program for Line-imaging ORVIS Measurements

LIVA (Line-Imaging Velocimetry Analysis) is a program for reducing data of a line-imaging optically recording velocity interferometer system (ORVIS) diagnostic. LIVA uses the Fourier transform method to extract phase information from recorded streak camera images. The extracted phase shift is used to infer target velocity as a function of space and time. The program can be run in any current version of MATLAB (2008a or later) or as a Windows XP executable.

Ao, Tommy↗