Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Results of the Aerosol Sampling Experiment on the International Space Station

The indoor air quality of the International Space Station (ISS), in terms of particulate matter, has been assessed through a sampling experiment that collected airborne debris for return to Earth. The Aerosol Sampling Experiment took place on ISS in December 2016 and January 2017, with sample return in February 2017. For redundancy, two different aerosol samplers collected particles in two size ranges spanning from 10 nm to hundreds of micrometers. Multiple analysis techniques have been used to characterize the particles, such as reflective light microscopy, manual scanning electron microscopy (SEM) analysis (secondary and backscattered imaging) with energy dispersive spectroscopy (EDS) x-ray analysis, computer controlled scanning electron microscopy (CCSEM) and Raman spectroscopy. Sampling took place in five locations on ISS, with the greatest deposition of particles in Node 3, followed by Node 1, the US Lab and Node 2. The PMM had very few airborne particles, as expected, owing to the lack of human presence. A large proportion of the sampled material consisted of fibers from clothing. Many particles had complex morphologies or contained multiple metals in a carbonaceous matrix. Metal particles were analyzed for each sampling location in terms of both weight and number percent, with 27 heavy metals detected. Fiberglass and TiO2 particles were present in every location. Quantitative analysis results are presented, and where possible, particle emission sources are identified with the intention to fuel discussions on mitigation.

Meyer, Marit E.↗

Measurement of Photons Emitted by High-Energy Charged Particles as Background in Single-Photon Resolving Image Sensors

This work introduces an advanced technique optimized for detecting photons generated by charged particles, leveraging Skipper charge coupled device (Skipper-CCD) image sensors. By analyzing background sources and detection efficiencies, the technique achieves strong agreement between experimental results and Cherenkov-based simulations. It also provides a robust framework for investigating secondary photon production in environments with high fluxes of ionizing particles, such as those anticipated in space-based astronomical instruments. These secondary photons present a critical challenge as background noise for next-generation single-photon resolving imagers used to study faint celestial objects. Furthermore, the method exhibits significant potential for broader applications, including exploring photon generation in various substrate materials and examining their transport through multiple interfaces.

Fernandez Moroni, Guillermo [Fermilab; Chicago U.,↗

SNM detection by active muon interrogation

Muons are charged particles with mass between the electron and proton and can be produced indirectly through pion decay by interaction of a charged-particle beam with a target. There are several distinct features of the muon interaction with matter attractive as a probe for detection of SNM at moderate ranges. These include muon penetration of virtually any amount of material without significant nuclear interaction until stopped by ionization loss in a short distance. When stopped, high-energy penetrating x-rays (in the range of 6 MeV for uranium,) unique to isotopic composition are emitted in the capture process. The subsequent interaction with the nucleus produces additional radiation useful in assessing SNM presence. A focused muon beam can be transported through the atmosphere, at a range limited mainly by beam-size growth through scattering. A muonbeam intensity of > 10{sup 9} /second is required for efficient interrogation and, as in any other technique, dose limits are to be respected. To produce sufficient muons a high-energy (threshold {approx}140 MeV) high-intensity (<1 mA) proton or electron beam is needed implying the use of a linear accelerator to bombard a refractory target. The muon yield is fractionally small, with large angle and energy dispersion, so that efficient collection is necessary in all dimensions of phase space. To accomplish this Los Alamos has proposed a magnetic collection system followed by a unique linear accelerator that provides the requisite phase-space bunching and allows an energy sweep to successively stop muons throughout a large structure such as a sea-going vessel. A possible maritime application would entail fitting the high-gradient accelerators on a large ship with a helicopter-borne detection system. We will describe our experimental results for muon effects and particle collection along with our current design and program for a muon detection system.

43 PARTICLE ACCELERATORS↗

Directional resolution of dish antenna experiments to search for WISPy dark matter

Dark matter consisting of very light and very weakly interacting particles such as axions, axion-like particles and hidden photons could be detected using reflective surfaces. On such reflectors some of the dark matter particles are converted into photons and, given a suitable geometry, concentrated on the detector. This technique offers sensitivity to the direction of the velocity of the dark matter particles. In this note we investigate how far spherical mirrors can concentrate the generated photons and what this implies for the resolution in directional detection as well as the sensitivity of discovery experiments not aiming for directional resolution. Finally we discuss an improved setup using a combination of a reflecting plane with focussing optics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Trapping of transuranium elements by the earth's magnetic field

The search for a transuranium element component of cosmic radiation has been carried out in high altitude balloon experiments. The trapping of high Z elements on orbits in the Earth's magnetic field may lead to a sufficient enhancement of the intensity of particle flux to make it possible to detect these elements by satellite experiments. Calculations are presented that predict the behavior of trapped particles as a function of the predicted flux and energy distribution of high Z elements incident on the Earth's magnetic field. Techniques are suggested for the detection of such particles. In addition, the possibility of production of transuranium elements in the recently discovered pulsars are discussed.

Bloom, J. L.↗

Assessment of velocity/trajectory measurement technologies during a particle capture event

Since the early 1960s, the means to measure the time of flight (TOF) of dust grain within a mechanical detection array has existed, first in the laboratory and then in space experiments. Laboratory hypervelocity dust particle accelerators have used electrostatic detection of charge on accelerated particles for TOF and particle mass detections. These laboratory studies have led to the development of ultra-thin-film sensors that have been used for TOF measurements in dust particle space experiments. The prototypes for such devices were ultra-thin-film capacitors that were used in the OGO series of satellites. The main goal of the experimental work to be described is the development of the capability to determine the velocity vector or trajectory of a dust grain traversing an integrated dust detection array. The results of these studies have shown that the capability of detecting the charge liberated by hypervelocity dust grains with diameters in the micrometer range can be detected. Based on these results, detection systems have been designed to provide a precise analysis of the physical and dynamic properties of micrometer and submicrometer dust grains, namely the design verification unit (DVU). Through unique combinations of in situ detection systems, direct measurements of particle surface charge, velocity, momentum, kinetic energy, and trajectory have been achieved. From these measurements, the remaining physical parameters of mass, size, and density can be determined.

Tanner, William G.↗

Effects of amorphous silica coating on cerium oxide nanoparticles induced pulmonary responses

Recently cerium compounds have been used in a variety of consumer products, including diesel fuel additives, to increase fuel combustion efficiency and decrease diesel soot emissions. However, cerium oxide (CeO{sub 2}) nanoparticles have been detected in the exhaust, which raises a health concern. Previous studies have shown that exposure of rats to nanoscale CeO{sub 2} by intratracheal instillation (IT) induces sustained pulmonary inflammation and fibrosis. In the present study, male Sprague–Dawley rats were exposed to CeO{sub 2} or CeO{sub 2} coated with a nano layer of amorphous SiO{sub 2} (aSiO{sub 2}/CeO{sub 2}) by a single IT and sacrificed at various times post-exposure to assess potential protective effects of the aSiO{sub 2} coating. The first acellular bronchoalveolar lavage (BAL) fluid and BAL cells were collected and analyzed from all exposed animals. At the low dose (0.15 mg/kg), CeO{sub 2} but not aSiO{sub 2}/CeO{sub 2} exposure induced inflammation. However, at the higher doses, both particles induced a dose-related inflammation, cytotoxicity, inflammatory cytokines, matrix metalloproteinase (MMP)-9, and tissue inhibitor of MMP at 1 day post-exposure. Morphological analysis of lung showed an increased inflammation, surfactant and collagen fibers after CeO{sub 2} (high dose at 3.5 mg/kg) treatment at 28 days post-exposure. aSiO{sub 2} coating significantly reduced CeO{sub 2}-induced inflammatory responses in the airspace and appeared to attenuate phospholipidosis and fibrosis. Energy dispersive X-ray spectroscopy analysis showed Ce and phosphorous (P) in all particle-exposed lungs, whereas Si was only detected in aSiO{sub 2}/CeO{sub 2}-exposed lungs up to 3 days after exposure, suggesting that aSiO{sub 2} dissolved off the CeO{sub 2} core, and some of the CeO{sub 2} was transformed to CePO{sub 4} with time. These results demonstrate that aSiO{sub 2} coating reduce CeO{sub 2}-induced inflammation, phospholipidosis and fibrosis. - Highlights: • Both CeO{sub 2} and aSiO{sub 2}/CeO{sub 2} particles were detected in the respective particle-exposed lungs. • The dissolution of aSiO{sub 2} coating from CeO{sub 2} particle core with time was demonstrated in the particle-exposed lungs. • aSiO{sub 2} coating significantly protected CeO{sub 2}-induced pulmonary inflammatory responses. • aSiO{sub 2} coating showed a protective effect on CeO{sub 2}-induced lung fibrosis.

60 APPLIED LIFE SCIENCES↗

A reversible time-of-flight detector for use in pseudocontinuous resonance enhanced multiphoton (pc-REMPI) detection

A time-of-flight coincidence detector is demonstrated. This detector is optimized for use in a pseudocontinuous resonance enhanced multiphoton ionization scheme that requires photoelectrons and photoions to be detected in coincidence. The detector utilizes two simultaneously operating charged particle detectors, one for the detection of electrons and the other for the detection of ions. In order to allow for field reversal, the detectors are physically identical, differing only by the value of applied voltages. Particular attention is given to the implementation of a charge-to-voltage transducer that allows for subnanosecond detection of both electrons and ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The cloud monitor by an infrared camera at the Telescope Array experiment

The mesurement of the extensive air shower using the fluorescence detectors (FDs) is affected by the condition of the atmosphere. In particular, FD aperture is limited by cloudiness. If cloud exists on the light path from extensive air shower to FDs, fluorescence photons will be absorbed drastically. Therefore cloudiness of FD's field of view (FOV) is one of important quality cut condition in FD analysis. In the Telescope Array (TA), an infrared (IR) camera with 320x236 pixels and a filed of view of 25.8 deg. x19.5 deg. has been installed at an observation site for cloud monitoring during FD observations. This IR camera measures temperature of the sky every 30 min during FD observation. IR camera is mounted on steering table, which can be changed in elevation and azimuthal direction. Clouds can be seen at a higher temperature than areas of cloudless sky from these temperature maps. In this paper, we discuss the quality of the cloud monitoring data, the analysis method, and current quality cut condition of cloudiness in FD analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation efficiency and ionization yield of liquid xenon for monoenergetic nuclear recoils down to 4 keV

Liquid xenon (LXe) is an excellent material for experiments designed to detect dark matter in the form of weakly interacting massive particles (WIMPs). A low energy detection threshold is essential for a sensitive WIMP search. The understanding of the relative scintillation efficiency (L{sub eff}) and ionization yield of low energy nuclear recoils in LXe is limited for energies below 10 keV. In this article, we present new measurements that extend the energy down to 4 keV, finding that L{sub eff} decreases with decreasing energy. We also measure the quenching of scintillation efficiency caused by the electric field in LXe, finding no significant field dependence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multipoint measurements of energetic particles in the magnetosphere

The benefits of energetic-particle measurements in the study of magnetospheric physics are reviewed, including the particles' relative ease of detection, their high rectilinear speed, their range of gyroradii, and their immunity to large-scale electric fields. With such particles, it is possible to observationally separate distinctive plasma regions, uniquely assess field-line topologies, examine connectivity from the magnetospheric equator to the ionosphere, and sense global changes in magnetospheric configuration. Multipoint measurements of energetic particles have contributed substantially to the understanding of the earth magnetopause, the leakage of particles into the upstream region, the effect of sudden storm compressions, the global nature of substorm dynamics, and the location and character of high-energy acceleration processes.

Baker, D. N.↗

NeutronSTARS: A segmented neutron and charged particle detector for low-energy reaction studies

NeutronSTARS (Neutron-Silicon Telescope Array for Reaction Studies) consists of 2.2-tons of gadolinium-doped liquid scintillator for neutron detection and large area silicon detectors for charged particle identification. This detector array is intended for low-energy-nuclear-reaction measurements that result in the emission of neutrons such as (n, xn) and fission. This paper describes the NeutronSTARS experimental setup, calibration, and the array’s response to neutral and charged particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmic-ray sum rules

We introduce new sum rules allowing to determine universal properties of the unknown component of the cosmic rays; we show how they can be used to predict the positron fraction at energies not yet explored by current experiments, and to constrain specific models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Planck 2013 results. X. HFI energetic particle effects: Characterization, removal, and simulation

We describe the detection, interpretation, and removal of the signal resulting from interactions of high energy particles with the Planck High Frequency Instrument (HFI). There are two types of interactions: heating of the 0.1 K bolometer plate; and glitches in each detector time stream. The transient responses to detector glitch shapes are not simple single-pole exponential decays and fall into three families. The glitch shape for each family has been characterized empirically in flight data and these shapes have been used to remove glitches from the detector time streams. The spectrum of the count rate per unit energy is computed for each family and a correspondence is made to the location on the detector of the particle hit. Most of the detected glitches are from Galactic protons incident on the die frame supporting the micro-machined bolometric detectors. In the Planck orbit at L2, the particle flux is around 5 cm -2 s -1 and is dominated by protons incident on the spacecraft with energy >39 MeV, at a rate of typically one event per second per detector. Different categories of glitches have different signatures in the time stream. Two of the glitch types have a low amplitude component that decays over nearly 1 s. This component produces excess noise if not properly removed from the time-ordered data. We have used a glitch detection and subtraction method based on the joint fit of population templates. The application of this novel glitch subtraction method removes excess noise from the time streams. Using realistic simulations, we find that this method does not introduce signal bias into the Planck data.

79 ASTRONOMY AND ASTROPHYSICS↗

Recent results from WASA-at-COSY

WASA--a 4{pi} spectrometer for detection of charged and neutral particles--started operation at the cooler synchrotron COSY-Juelich in 2007. A number of experiments on meson production and decays have been carried out since then. The status of the analysis and preliminary results of some selected topics from the physics program are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-J-149: Secondary Emission Detection for Improved Proton Relative Stopping Power Identification

Purpose: This research investigates application of secondary prompt gamma (PG) emission spectra, resulting from nuclear reactions induced by protons, to characterize tissue composition along the particle path. The objective of utilizing the intensity of discrete high-energy peaks of PG is to improve the accuracy of relative stopping power (RSP) values available for proton therapy treatment planning on a patient specific basis and to reduce uncertainty in dose depth calculations. Methods: In this research, MCNP6 was used to simulate PG emission spectra generated from proton induced nuclear reactions in medium of varying composition of carbon, oxygen, calcium and nitrogen, the predominant elements found in human tissue. The relative peak intensities at discrete energies predicted by MCNP6 were compared to the corresponding atomic composition of the medium. Results: The results have shown a good general agreement with experimentally measured values reported by other investigators. Unexpected divergence from experimental spectra was noted in the peak intensities for some cases depending on the source of the cross-section data when using compiled proton table libraries vs. physics models built into MCNP6. While the use of proton cross-section libraries is generally recommended when available, these libraries lack data for several less abundant isotopes. This limits the range of their applicability and forces the simulations to rely on physics models for reactions with natural atomic compositions. Conclusion: Current end-of-range proton imaging provides an average RSP for the total estimated track length. The accurate identification of tissue composition along the incident particle path using PG detection and characterization allows for improved determination of the tissue RSP on the local level. While this would allow for more accurate depth calculations resulting in tighter treatment margins, precise understanding of proton beam behavior in tissue of various compositions is necessary requiring detailed simulations with a high degree of accuracy.

60 APPLIED LIFE SCIENCES↗

PAMELA Results on the Cosmic-Ray Antiproton Flux from 60 MeV to 180 GeV in Kinetic Energy

The satellite-borne experiment PAMELA has been used to make a new measurement of the cosmic-ray antiproton flux and the antiproton-to-proton flux ratio which extends previously published measurements down to 60 MeV and up to 180 GeV in kinetic energy. During 850 days of data acquisition approximately 1500 antiprotons were observed. The measurements are consistent with purely secondary production of antiprotons in the Galaxy. More precise secondary production models are required for a complete interpretation of the results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A ton-scale bolometric detector for the search for neutrinoless double beta decay

After an introduction on neutrinoless double beta decay physics, a description of CUORE and CUORICINO experiments, detectors and results are reported. The actual efforts and next steps of the CUORE Project, required to probe the inverted hierarchy region of the neutrino effective Majorana mass, are also described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗