Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Living on the edge: a non-perturbative resolution to the negativity of bulk entropies

Lin, Maldacena, Rozenberg, and Shan (LMRS) presented a new information paradox in black hole physics by noticing that the entanglement and Rényi entropies in a two-sided black hole can become negative when the geometry contains a very large number of matter excitations behind the black hole horizon. While originally this puzzle was presented in the context of BPS two-sided black holes in two-dimensional supergravity, the negativity in fact persists for more general two-sided black holes in the presence of a large number of matter excitations. Since the entanglement and Rényi entropies in ordinary quantum systems cannot be negative, resolving this puzzle is a necessary step towards understanding the quantum mechanical description of black holes. In this paper, we explain how to address the entanglement negativity puzzle, both in the original setting discussed by LMRS and in more general non-supersymmetric settings, by summing over all non-perturbative contributions to the gravitational path integral. We then interpret this result from the point of view of a dual matrix integral, which we use to extend our analysis beyond the regime of validity of the genus re-summation performed in the gravitational path integral. In this regime, positivity is rescued by new saddles of the matrix integral, a one-eigenvalue instanton and a two-eigenvalue instanton. Finally, we formulate a similar puzzle and its resolution using random tensor network techniques.

2D Gravity↗

Living on the edge: a non-perturbative resolution to the negativity of bulk entropies

Lin, Maldacena, Rozenberg, and Shan (LMRS) presented a new information paradox in black hole physics by noticing that the entanglement and Rényi entropies in a two-sided black hole can become negative when the geometry contains a very large number of matter excitations behind the black hole horizon. While originally this puzzle was presented in the context of BPS two-sided black holes in two-dimensional supergravity, the negativity in fact persists for more general two-sided black holes in the presence of a large number of matter excitations. Since the entanglement and Rényi entropies in ordinary quantum systems cannot be negative, resolving this puzzle is a necessary step towards understanding the quantum mechanical description of black holes. In this paper, we explain how to address the entanglement negativity puzzle, both in the original setting discussed by LMRS and in more general non-supersymmetric settings, by summing over all non-perturbative contributions to the gravitational path integral. We then interpret this result from the point of view of a dual matrix integral, which we use to extend our analysis beyond the regime of validity of the genus re-summation performed in the gravitational path integral. In this regime, positivity is rescued by new saddles of the matrix integral, a one-eigenvalue instanton and a two-eigenvalue instanton. Finally, we formulate a similar puzzle and its resolution using random tensor network techniques.

FOS: Physical sciences↗

An Aerial Radiological Survey of Selected Areas of Area 18 - Nevada Test Site

As part of the proficiency training for the Radiological Mapping mission of the Aerial Measuring System (AMS), a survey team from the Remote Sensing Laboratory-Nellis (RSL-Nellis) conducted an aerial radiological survey of selected areas of Area 18 of the Nevada Test Site (NTS) for the purpose of mapping man-made radiation deposited as a result of the Johnnie Boy and Little Feller I tests. The survey area centered over the Johnnie Boy ground zero but also included the ground zero and deposition area of the Little Feller I test, approximately 7,000 feet (2133 meters) southeast of the Johnnie Boy site. The survey was conducted in one flight. The completed survey covered a total of 4.0 square miles. The flight lines (with the turns) over the surveyed areas are presented in Figure 1. One 2.5-hour-long flight was performed at an altitude of 100 ft above ground level (AGL) with 200 foot flight-line spacing. A test-line flight was conducted near the Desert Rock Airstrip to ensure quality control of the data. The test line is not shown in Figure 1. However, Figure 1 does include the flight lines for a ''perimeter'' flight. The path traced by the helicopter flying over distinct roads within the survey area can be used to overlay the survey data on a base map or image. The flight survey lines were flown in an east-west orientation perpendicular to the deposition patterns for both sites. This technique provides better spatial resolution when contouring the data. The data were collected by the AMS data acquisition system (REDAR V) using an array of twelve 2-inch x 4-inch x 16-inch sodium iodide (NaI) detectors flown on-board a twin-engine Bell 412 helicopter. Data, in the form of gamma energy spectra, were collected every second over the course of the survey and were geo-referenced using a differential Global Positioning System. Spectral data allows the system to distinguish between ordinary fluctuations in natural background radiation levels and the signature produced by man-made radioisotopes. Spectral data can also identify specific radioactive isotopes. Based on the results of the RSL NTS 1994 surveys, this area was chosen for a resurvey to improve the spatial resolution of the reported depositions for the Johnnie Boy and Little Feller I events. In addition, the survey was expected to confirm the absence of detectable concentrations of Americium-241 (Am-241) at the Johnnie Boy site and attempt to confirm the presence of Uranium-235 (U-235).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

U2504 Determines the Species Specificity of the A-Site Cleft Antibiotics: The Structures of Tiamulin, Homoharringtonine, and Bruceantin Bound to the Ribosome

Structures have been obtained for the complexes that tiamulin, homoharringtonine, and bruceantin form with the large ribosomal subunit of Haloarcula marismortui at resolutions ranging from 2.65 to 3.2 {angstrom}. They show that all these inhibitors block protein synthesis by competing with the amino acid side chains of incoming aminoacyl-tRNAs for binding in the Asite cleft in the peptidyl-transferase center, which is universally conserved. In addition, these structures support the hypothesis that the species specificity exhibited by the A-site cleft inhibitors is determined by the interactions they make, or fail to make, with a single nucleotide, U2504 (Escherichia coli). In the ribosome, the position of U2504 is controlled by its interactions with neighboring nucleotides, whose identities vary among kingdoms.

59 BASIC BIOLOGICAL SCIENCES↗

Microangiography in Living Mice Using Synchrotron Radiation

Traditionally, there are no methods available to detect the fine morphologic changes of cerebrovasculature in small living animals such as rats and mice. Newly developed synchrotron radiation microangiography can achieve a fine resolution of several micrometers and had provided us with a powerful tool to study the cerebral vasculature in small animals. The purpose of this study is to identify the morphology of cerebrovasculature especially the structure of Lenticulostriate arteries (LSAs) in living mice using the synchrotron radiation source at Shanghai Synchrotron Radiation Facility (SSRF) in Shanghai, China. Adult CD-1 mice weighing 35-40 grams were anesthetized. Nonionic iodine (Omnipaque, 350 mg I /mL) was used as a contrast agent. The study was performed at the BL13W1 beam line at SSRF. The beam line was derived from a storage ring of electrons with an accelerated energy of 3.5 GeV and an average beam current of 200 mA. X-ray energy of 33.3 keV was used to produce the highest contrast image. Images were acquired every 172 ms by a x-ray camera (Photonic-Science VHR 1.38) with a resolution of 13 {mu}m/pixel. The optimal dose of contrast agent is 100 {mu}l per injection and the injecting rate is 33 {mu}l/sec. The best position for imaging is to have the mouse lay on its right or left side, with ventral side facing the X-ray source. We observed the lenticulostriate artery for the first time in living mice. Our result show that there are 4 to 5 lenticulostriate branches originating from the root of middle cerebral artery in each hemisphere. LSAs have an average diameter of 43{+-}6.8 {mu}m. There were no differences between LSAs from the left and right hemisphere (p<0.05). These results suggest that synchrotron radiation may provide a unique tool for experimental stroke research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive sampling for accelerating neutron diffraction-based strain mapping *

Abstract Neutron diffraction is a useful technique for mapping residual strains in dense metal objects. The technique works by placing an object in the path of a neutron beam, measuring the diffracted signals and inferring the local lattice strain values from the measurement. In order to map the strains across the entire object, the object is stepped one position at a time in the path of the neutron beam, typically in raster order, and at each position a strain value is estimated. Typical dwell times at neutron diffraction instruments result in an overall measurement that can take several hours to map an object that is several tens of centimeters in each dimension at a resolution of a few millimeters, during which the end users do not have an estimate of the global strain features and are at risk of incomplete information in case of instruments outages. In this paper, we propose an object adaptive sampling strategy to measure the significant points first. We start with a small initial uniform set of measurement points across the object to be mapped, compute the strain in those positions and use a machine learning technique to predict the next position to measure in the object. Specifically, we use a Bayesian optimization based on a Gaussian process regression method to infer the underlying strain field from a sparse set of measurements and predict the next most informative positions to measure based on estimates of the mean and variance in the strain fields estimated from the previously measured points. We demonstrate our real-time measure-infer-predict workflow on additively manufactured steel parts—demonstrating that we can get an accurate strain estimate even with 30%–40% of the typical number of measurements—leading the path to faster strain mapping with useful real-time feedback. We emphasize that the proposed method is general and can be used for fast mapping of other material properties such as phase fractions from time-consuming point-wise neutron measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Chemical identification of new particle formation and growth precursors through positive matrix factorization of ambient ion measurements

Abstract. In the lower troposphere, rapid collisions between ions and trace gases result in the transfer of positive charge to the highest proton affinity species and negative charge to the lowest proton affinity species. Measurements of the chemical composition of ambient ions thus provide direct insight into the most acidic and basic trace gases and their ion–molecule clusters – compounds thought to be important for new particle formation and growth. We deployed an atmospheric pressure interface time-of-flight mass spectrometer (APi-ToF) to measure ambient ion chemical composition during the 2016 Holistic Interactions of Shallow Clouds, Aerosols, and Land Ecosystems (HI-SCALE) campaign at the United States Department of Energy Atmospheric Radiation Measurement facility in the Southern Great Plains (SGP), an agricultural region. Cations and anions were measured for alternating periods of ∼ 24 h over 1 month. We use binned positive matrix factorization (binPMF) and generalized Kendrick analysis (GKA) to obtain information about the chemical formulas and temporal variation in ionic composition without the need for averaging over a long timescale or a priori high-resolution peak fitting. Negative ions consist of strong acids including sulfuric and nitric acid, organosulfates, and clusters of NO3- with highly oxygenated organic molecules (HOMs) derived from monoterpene (MT) and sesquiterpene (SQT) oxidation. Organonitrates derived from SQTs account for most of the HOM signal. Combined with the diel profiles and back trajectory analysis, these results suggest that NO3 radical chemistry is active at this site. SQT oxidation products likely contribute to particle growth at the SGP site. The positive ions consist of bases including alkyl pyridines and amines and a series of high-mass species. Nearly all the positive ions contained only one nitrogen atom and in general support ammonia and amines as being the dominant bases that could participate in new particle formation. Overall, this work demonstrates how APi-ToF measurements combined with binPMF analysis can provide insight into the temporal evolution of compounds important for new particle formation and growth.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser Tracker Calibration - Testing the Angle Measurement System -

Physics experiments at the SLAC National Accelerator Laboratory (SLAC) usually require high accuracy positioning, e. g. 100 {micro}m over a distance of 150 m or 25 {micro}m in a 10 x 10 x 3 meter volume. Laser tracker measurement systems have become one of the most important tools for achieving these accuracies when mapping components. The accuracy of these measurements is related to the manufacturing tolerances of various individual components, the resolutions of measurement systems, the overall precision of the assembly, and how well imperfections can be modeled. As with theodolites and total stations, one can remove the effects of most assembly and calibration errors by measuring targets in both direct and reverse positions and computing the mean to obtain the result. However, this approach does not compensate for errors originating from the encoder system. In order to improve and gain a better understanding of laser tracker angle measurement tolerances we extended our laboratory's capabilities with the addition of a horizontal angle calibration test stand. This setup is based on the use of a high precision rotary table providing an angular accuracy of better than 0.2 arcsec. Presently, our setup permits only tests of the horizontal angle measurement system. A test stand for vertical angle calibration is under construction. Distance measurements (LECOCQ & FUSS, 2000) are compared to an interferometer bench for distances of up to 32 m. Together both tests provide a better understanding of the instrument and how it should be operated. The observations also provide a reasonable estimate of covariance information of the measurements according to their actual performance for network adjustments.

43 PARTICLE ACCELERATORS↗

Saccharomycotina yeasts defy long-standing macroecological patterns

The Saccharomycotina yeasts (“yeasts” hereafter) are a fungal clade of scientific, economic, and medical significance. Yeasts are highly ecologically diverse, found across a broad range of environments in every biome and continent on earth; however, little is known about what rules govern the macroecology of yeast species and their range limits in the wild. Here, we trained machine learning models on 12,816 terrestrial occurrence records and 96 environmental variables to infer global distribution maps at ~1 km2 resolution for 186 yeast species (~15% of described species from 75% of orders) and to test environmental drivers of yeast biogeography and macroecology. We found that predicted yeast diversity hotspots occur in mixed montane forests in temperate climates. Diversity in vegetation type and topography were some of the greatest predictors of yeast species richness, suggesting that microhabitats and environmental clines are key to yeast diversity. We further found that range limits in yeasts are significantly influenced by carbon niche breadth and range overlap with other yeast species, with carbon specialists and species in high-diversity environments exhibiting reduced geographic ranges. Finally, yeasts contravene many long-standing macroecological principles, including the latitudinal diversity gradient, temperature-dependent species richness, and a positive relationship between latitude and range size (Rapoport’s rule). These results unveil how the environment governs the global diversity and distribution of species in the yeast subphylum. These high-resolution models of yeast species distributions will facilitate the prediction of economically relevant and emerging pathogenic species under current and future climate scenarios.

59 BASIC BIOLOGICAL SCIENCES↗

IMAGINE: first neutron protein structure and new capabilities for neutron macromolecular crystallography

The first high-resolution neutron protein structure of perdeuterated rubredoxin from Pyrococcus furiosus ( Pf Rd) determined using the new IMAGINE macromolecular neutron crystallography instrument at the Oak Ridge National Laboratory is reported. Neutron diffraction data extending to 1.65 Å resolution were collected from a relatively small 0.7 mm 3 Pf Rd crystal using 2.5 d (60 h) of beam time. The refined structure contains 371 out of 391, or 95%, of the D atoms of the protein and 58 solvent molecules. The IMAGINE instrument is designed to provide neutron data at or near atomic resolution (1.5 Å) from crystals with volume <1.0 mm 3 and with unit-cell edges <100 Å. Beamline features include novel elliptical focusing mirrors that deliver neutrons into a 2.0 × 3.2 mm focal spot at the sample position with full-width vertical and horizontal divergences of 0.5 and 0.6°, respectively. Variable short- and long-wavelength cutoff optics provide automated exchange between multiple-wavelength configurations (λ min = 2.0, 2.8, 3.3 Å to λ max = 3.0, 4.0, 4.5, ~20 Å). These optics produce a more than 20-fold increase in the flux density at the sample and should help to enable more routine collection of high-resolution data from submillimetre-cubed crystals. Notably, the crystal used to collect these Pf Rd data was 5–10 times smaller than those previously reported.

Meilleur, Flora↗

Electronic d-band properties of gold nanoclusters grown on amorphous carbon

The electronic d-band properties are important factors for the emerging catalytic activity of Au nanoclusters of sub-5-nm size. We analyzed the d-band properties of Au nanoclusters grown on amorphous carbon supports by photoelectron spectroscopy using synchrotron-radiation light coupled with high-resolution ion scattering spectrometry which enables us to estimate the size and shape of Au nanoclusters. The d-band width (W{sub d}), d-band center position (E{sub d}), and apparent 5d{sub 3/2}-d{sub 5/2} spin-orbit splitting (E{sub SO}) were determined as a function of a number of Au atoms per cluster (n{sub A}) and an average coordination number (n{sub C}) in a wide range (11<n{sub A}<1600). The W{sub d} and E{sub SO} values decrease steeply with decreasing n{sub A} below {approx}150 owing to band narrowing which is caused by hybridization of fewer wave functions of the valence electrons. However, E{sub d} shifts to the higher binding energy side with decreasing cluster size. The rapid movement of E{sub d} is attributed to the dynamic final-state effect, which results in higher binding energy shifts of core and valence states due to a positive hole created after photoelectron emission. We have estimated the contribution from the final-state effect and derived the approximated initial-state spectra. Modified data, however, still show a slight movement of the d-band center away from the Fermi level (E{sub F}) although the E{sub d} values for Au nanoclusters are closer to E{sub F} compared to the bulk value. This behavior is ascribed to the contraction of average Au-Au bond length with decreasing cluster size.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Interpreting Temperature Strain Data from Meso-Scale Clathrate Experiments

Gas hydrates are important in global climate change, carbon sequestra- tion, and seafloor stability. Currently, formation and dissociation pathways are poorly defined. We present a new approach for processing large amounts of data from meso-scale experiments, such as the LUNA distributed sensing system (DSS) in the seafloor process simulator (SPS) at Oak Ridge National Laboratory. The DSS provides a proxy for temperature measurement with a high spatial resolution allowing the heat of reaction during gas hydrate formation/dissociation to aid in locating clathrates in the vessel. The DSS fibers are placed in the sediment following an Archimedean spiral design and then the position of each sensor is solved by iterating over the arc length formula with Newtons method. The data is then gridded with 1 a natural neighbor interpolation algorithm to allow contouring of the data. The solution of the sensor locations is verified with hot and cold stimulus in known locations. An experiment was preformed with a vertically split column of sand and silt. The DSS system clearly showed hydrate forming in the sand first, then slowly creeping into the silt. Similar systems and data processing techniques could be used for monitoring of hydrates in natural environments or in any situation where a hybrid temperature/strain index is useful. Further ad- vances in fiber technology allow the fiber to be applied in any configuration and the position of each sensor to be precisely determined making practical applications easier.

54 ENVIRONMENTAL SCIENCES↗

High accuracy plasma density measurement using hybrid Langmuir probe and microwave interferometer method

High spatial resolution plasma density measurements have been taken as part of an investigation into magnetic nozzle physics at the NASA/MSFC Propulsion Research Center. These measurements utilized a Langmuir triple probe scanned across the measurement chord of either of two stationary rf interferometers. By normalizing the scanned profile to the microwave interferometer line-integrated density measurement for each electrostatic probe measurement, the effect of shot-to-shot variation of the line-integrated density can be removed. In addition, by summing the voltage readings at each radial position in a transverse scan, the line density can be reconstituted, allowing the absolute density to be determined, assuming that the shape of the profile is constant from shot to shot. The spatial and temporal resolutions of this measurement technique depend on the resolutions of the scanned electrostatic probe and the interferometer. The measurement accuracy is 9%-15%, which is on the order of the accuracy of the rf interferometer. The measurement technique was compared directly with both scanning rf interferometer and standard Langmuir probe theory. The hybrid technique compares favorably with the scanning rf interferometer, and appears more accurate than probe theory alone. Additionally, our measurement technique is generally applicable even for nonaxisymmetric plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resolution and sensitivity of a Fabry-Perot interferometer with a photon-number-resolving detector

With photon-number resolving detectors, we show compression of interference fringes with increasing photon numbers for a Fabry-Perot interferometer. This feature provides a higher precision in determining the position of the interference maxima compared to a classical detection strategy. We also theoretically show supersensitivity if N-photon states are sent into the interferometer and a photon-number resolving measurement is performed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cushing's syndrome mutant PKA L205R exhibits altered substrate specificity

The PKA L205R hotspot mutation has been implicated in Cushing's syndrome through hyperactive gain-of-function PKA signaling; however, its influence on substrate specificity has not been investigated. Here, we employ the Proteomic Peptide Library (ProPeL) approach to create high-resolution models for PKA WT and PKA L205R substrate specificity. We reveal that the L205R mutation reduces canonical hydrophobic preference at the substrate P + 1 position, and increases acidic preference in downstream positions. Using these models, we designed peptide substrates that exhibit altered selectivity for specific PKA variants, and demonstrate the feasibility of selective PKA L205R loss-of-function signaling. Through these results, we suggest that substrate rewiring may contribute to Cushing's syndrome disease etiology, and introduce a powerful new paradigm for investigating mutation-induced kinase substrate rewiring in human disease.

59 BASIC BIOLOGICAL SCIENCES↗

The effect of Ce{sup 4+} incorporation on structural, morphological and photocatalytic characters of ZnO nanoparticles

We report a simple chemical precipitation method for the preparation of undoped and cerium doped ZnO nanocrystals. The concentration of cerium in the products can be controlled in the range of 0.025–0.125 mol. The structure and chemical compositions of the products were characterized by X-ray diffraction, X-ray photoelectron spectroscopy; energy dispersive spectrum and Fourier transform infrared spectroscopy. The results demonstrate that Ce{sup 4+} ions were successfully incorporated into the lattice position of Zn{sup 2+} ions in ZnO. The morphology of the products was analyzed by field emission scanning electron microscopy and confirmed by high resolution transmission electron microscope analysis. The optical properties of the products were studied by ultraviolet–visible and room temperature photoluminescence measurements. The photoluminescence emission spectra of Ce-doped ZnO showed enhanced visible emissions as a result of 5d → 4f transition of cerium. In particular, a novel photocatalytic activity of the products was assessed using methylene blue. The obtained result reveals that Ce-doped products show higher reduction efficiency for methylene blue than the undoped ZnO. - Highlights: • Nanocrystals of ZnO and ZnO:Ce{sup 4+} were grown. • XPS results confirmed the incorporated cerium in tetravalence. • PL emission exhibited 5d → 4f transition on cerium doping. • Doped ZnO decolorizes MB faster than undoped ZnO.

36 MATERIALS SCIENCE↗

Time-of-flight secondary ion mass spectrometry with transmission of energetic primary cluster ions through foil targets

We developed time-of-flight (TOF) secondary ion (SI) mass spectrometry that provides informative SI ion mass spectra without needing a sophisticated ion beam pulsing system. In the newly developed spectrometry, energetic large cluster ions with energies of the order of sub MeV or greater are used as primary ions. Because their impacts on the target surface produce high yields of SIs, the resulting SI mass spectra are informative. In addition, the start signals necessary for timing information on primary ion incidence are provided by the detection signals of particles emitted from the rear surface of foil targets upon transmission of the primary ions. This configuration allows us to obtain positive and negative TOF SI mass spectra without pulsing system, which requires precise control of the primary ions to give the spectra with good mass resolution. We also successfully applied the TOF SI mass spectrometry with energetic cluster ion impacts to the chemical structure characterization of organic thin film targets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitive fast electron spectrometer in adjustable triode configuration with pulsed tunable laser for research on photo-induced field emission cathodes

We have completed an ultra-high vacuum system for sensitive fast electron spectroscopy from cold cathodes in triode configuration under high electric fields E (<100 MV/m) and pulsed tunable laser illumination (3.5 ns, 10 Hz, hν = 0.5-5.9 eV, and 0.3-17 mJ). The cathodes are prepared and inserted under clean room conditions and can be precisely 3D-positioned, cooled or heated (77-400 K). Commissioning results with the upgraded system are presented. Field emission measurements with a W tip yielded an energy resolution of 14 meV at 4 eV pass energy and a precise determination of the emitter work function, size, and temperature. Photoemission spectroscopy of short electron bunches from a virgin and laser-ablated S-GaP crystal and quantum efficiency measurements revealed surface states, energy relaxation, and band structure effects. In conclusion, this novel system is ready now for the development and characterization of photo-induced field emission cathodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗