Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiator Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

The IBA Easy-E-Beam Integrated Processing System

IBA Industrial Inc., (formerly known as Radiation Dynamics, Inc.) has been making high-energy and medium-energy, direct-current proton and electron accelerators for research and industrial applications for many years. Some industrial applications of high-power electron accelerators are the crosslinking of polymeric materials and products, such as the insulation on electrical wires, multi-conductor cable jackets, heat-shrinkable plastic tubing and film, plastic pipe, foam and pellets, the partial curing of rubber sheet for automobile tire components, and the sterilization of disposable medical devices. The curing (polymerization and crosslinking) of carbon and glass fiber-reinforced composite plastic parts, the preservation of foods and the treatment of waste materials are attractive possibilities for future applications. With electron energies above 1.0 MeV, the radiation protection for operating personnel is usually provided by surrounding the accelerator facility with thick concrete walls. With lower energies, steel and lead panels can be used, which are substantially thinner and more compact than the equivalent concrete walls. IBA has developed a series of electron processing systems called Easy-e-Beam for the medium energy range from 300 keV to 1000 keV. These systems include the shielding as an integral part of a complete radiation processing facility. The basic concepts of the electron accelerator, the product processing equipment, the programmable control system, the configuration of the radiation shielding and some performance characteristics are described in this paper.

07 ISOTOPE AND RADIATION SOURCES↗

Fabrication and performance analysis of 4-sq cm indium tin oxide/InP photovoltaic solar cells

Large-area photovoltaic solar cells based on direct current magnetron sputter deposition of indium tin oxide (ITO) into single-crystal p-InP substrates demonstrated both the radiation hardness and high performance necessary for extraterrestrial applications. A small-scale production project was initiated in which approximately 50 ITO/InP cells are being produced. The procedures used in this small-scale production of 4-sq cm ITO/InP cells are presented and discussed. The discussion includes analyses of performance range of all available production cells, and device performance data of the best cells thus far produced. Additionally, processing experience gained from the production of these cells is discussed, indicating other issues that may be encountered when large-scale productions are begun.

Gessert, T. A.↗

Perspectives on radiation effects in nickel-base alloys for applications in advanced reactors

Because of their superior high temperature strength and corrosion properties, a set of Ni-base alloys has been proposed for various in-core applications in Gen IV reactor systems. However, irradiation-performance data for these alloys is either limited or non-existent. A review is presented of the irradiation-performance of a group of Ni-base alloys based upon data from fast breeder reactor programs conducted in the 1975 1985 timeframe with emphasis on the mechanisms involved in the loss of high temperature ductility and the breakdown in swelling resistance with increasing neutron dose. The implications of these data for the performance of the Gen IV Ni-base alloys are discussed and possible pathways to mitigate the effects of irradiation on alloy performance are outlined. A radical approach to designing radiation damage-resistant Ni alloys based upon recent advances in mechanical alloying is also described.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

LOCAL ABSORPTION OF HIGH-ENERGY EMISSION FROM GAMMA-RAY BURSTS

High-energy photons emitted from gamma-ray bursts (GRBs) are subject to pair-production interactions with lower energy photons, leading to an effective optical depth. In this paper, we estimate the opacity resulting from photon fields located at various distances from long GRB sites: those of the binary companion to the massive stellar progenitor, the star-forming molecular cloud containing the GRB, and the total photon field of the host galaxy. The first two photon fields are found to be transparent for most reasonable sets of assumptions about these systems. In the case of galactic radiation fields, we have performed several numerical simulations to calculate the expected opacities for two different line-of-sight geometries through the host galaxy and include a full accounting of the infrared radiation produced by the absorption and re-radiation of starlight by dust. The optical depth for GeV gamma rays due to direct starlight is less than unity for all host galaxies. At higher energies, >10 TeV, a spectral cutoff can occur due to the rapidly increasing number of mid- to far-IR intragalactic photons re-radiated by dust. Photons in the extragalactic background light therefore remain the only relevant source of photon-photon opacity for ongoing GRB observations with Fermi-LAT and potential future detections with ground-based gamma-ray telescopes.

79 ASTRONOMY AND ASTROPHYSICS↗

EMI Shields made from intercalated graphite composites

Electromagnetic interference (EMI) shielding typically makes up about twenty percent of the mass of a spacecraft power system. Graphite fiber/polymer composites have significantly lower densities and higher strengths than aluminum, the present material of choice for EMI shields, but they lack the electrical conductivity that enables acceptable shielding effectiveness. Bromine intercalated pitch-based graphite/epoxy composites have conductivities fifty times higher than conventional structural graphite fibers. Calculations are presented which indicate that EMI shields made from such composites can have sufficient shielding at less than 20% of the mass of conventional aluminum shields. EMI shields provide many functions other than EMI shielding including physical protection, thermal management, and shielding from ionizing radiation. Intercalated graphite composites perform well in these areas also. Mechanically, they have much higher specific strength and modulus than aluminum. They also have shorter half thicknesses for x-rays and gamma radiation than aluminum. Thermally, they distribute infra-red radiation by absorbing and re-radiating it rather than concentrating it by reflection as aluminum does. The prospects for intercalated graphite fiber/polymer composites for EMI shielding are encouraging.

Gaier, James R.↗

Multicenter Collaborative Quality Assurance Program for the Province of Ontario, Canada: First-Year Results

Purpose: The objective of this work was to develop a collaborative quality assurance (CQA) program to assess the performance of intensity modulated radiation therapy (IMRT) planning and delivery across the province of Ontario, Canada. Methods and Materials: The CQA program was designed to be a comprehensive end-to-end test that can be completed on multiple planning and delivery platforms. The first year of the program included a head-and-neck (H and N) planning exercise and on-site visit to acquire dosimetric measurements to assess planning and delivery performance. A single dosimeter was used at each institution, and the planned to measured dose agreement was evaluated for both the H and N plan and a standard plan (linear-accelerator specific) that was created to enable a direct comparison between centers with similar infrastructure. Results: CQA program feasibility was demonstrated through participation of all 13 radiation therapy centers in the province. Planning and delivery was completed on a variety of infrastructure (treatment planning systems and linear accelerators). The planning exercise was completed using both static gantry and rotational IMRT, and planned-to-delivered dose agreement (pass rates) for 3%/3-mm gamma evaluation were greater than 90% (92.6%-99.6%). Conclusions: All centers had acceptable results, but variation in planned to delivered dose agreement for the same planning and delivery platform was noted. The upper end of the range will provide an achievable target for other centers through continued quality improvement, aided by feedback provided by the program through the use of standard plans and simple test fields.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calibration and Initial Results of Space Radiation Dosimetry Using the iMESA-R

The integrated Miniaturized Electrostatic Analyzer-Reflight (iMESA-R) is a space weather instrument designed to measure plasma density, temperature, and spacecraft charging, along with total ionizing dose and dose rate. A constellation consisting of five nearly identical instruments has been designed and developed to act as science payloads hosted on-board Department of Defense satellites operating in low-Earth orbit. To validate the dosimetry component of the iMESA-R, a radiation test study was performed to calibrate the dosimeter and ascertain the attenuation due to the instrument aluminum housing. An 80 curie Cobalt-60 radioisotope source emitting beta, X-ray, and gamma ray radiation decay products was used to calibrate the dosimeter response as a function of distance and instrument shielding. We present results of the calibration study along with initial on-orbit data presented from the first operational iMESA-R hosted on-board Space Test Program Satellite 5 in a polar Earth orbit. The initial on-orbit data demonstrate the ability to map the radiation environment, particularly the South Atlantic Anomaly and the auroral regions using total ionizing dose rate due to electrons of E > 1.5 MeV and protons of E > 25 MeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectroscopic Measurements and Models of Energy Deposition in the Substrate of Quantum Circuits by Natural Ionizing Radiation

Naturally occurring background radiation is a potential source of correlated decoherence events in superconducting qubits that will challenge error-correction schemes. In order to characterize the radiation environment in an unshielded laboratory representative of superconducting qubits’ environments, we performed broadband, spectroscopic measurements of background radiation events inside a millikelvin refrigerator. The spectrometer was designed to mimic the size and composition of a quantum circuit. Specifically, we measured the background radiation spectra in silicon substrates of two thicknesses, 500 and 1500 µm, and one area, 25 mm 2 . The observed spectra span energies from a few kilo-electron-volts up to nearly 10 MeV, are nearly featureless, and decrease in intensity by a factor of 40 000 between 100 keV and 3 MeV for the 500-µm substrate. We integrate the spectra to obtain the average event rates and deposited power levels. These quantities correspond to a rate of 0.023 events per second and a power of 4.9 keV s -1 , when counting events that deposit at least 40 keV for the 500-µm-thick substrate. We find that the cryogenic measurements are in good agreement with predictions based on simple measurements of the terrestrial gamma-ray flux outside the refrigerator, published models of cosmic-ray fluxes, a crude model of the cryostat, and radiation-transport simulations. This model requires no free parameters to predict the background radiation spectra in the silicon substrates. The agreement between measurements and predictions demonstrates that the model we present can be used to assess the relative contributions of terrestrial and cosmic-ray sources to background radiation interactions in silicon substrates of varying thickness. These spectroscopic measurements are performed with a novel combination of superconducting microresonators located on micromachined silicon islands that define the interaction volume with background radiation. The resonators transduce deposited energy to a readily detectable electrical signal. Microresonator readout closely resembles dispersive superconducting qubit readout, so similar devices—with or without micromachined islands—are suitable for integration with superconducting quantum circuits as detectors for background radiation events. For our specific laboratory conditions, we find that gamma-ray emissions from radioisotopes are responsible for the majority of events that deposit E < 1 ⁢Me⁢V. We present results demonstrating that the background radiation spectrum contains relevant contributions from cosmic-ray particles other than muons, particularly a tail of multi-mega-electron-volt events due to protons and neutrons. These observations suggest several paths to reducing the impact of background radiation on quantum circuits, supported by an empirically validated model for generating reliable predictions of radiation interactions with silicon substrates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of V-groove radiator configuration

In the design of spacecraft radiators intended to provide cryogenic cooling, it is important to minimize the space occupied by radiator shielding while satisfying the performance requirements. This study develops and tests the first step toward optimizing radiator shield configurations and examines the design of the highly effective V-groove radiator concept. This investigation, which makes use of a special purpose Monte Carlo/ray tracing computer program, directly identifies the two shield configuration which minimizes radiator footprint for a given temperature drop. Furthermore, multiple shield configurations may be analyzed through a combination of analysis and program statistics. The results presented demonstrate the sensitivity of intershield temperature drop to shield angle and/or offset and provide a comparison of angled and parallel shield configurations. Good agreement with experimental data is shown for a multiple shield configuration.

Schember, Helene R.↗

Application of adaptive multilevel splitting on coupled neutron-photon TRIPOLI-4{sup R} Monte Carlo simulations - 25427

In the context of radiation protection simulations, the Adaptive Multilevel Splitting (AMS) algorithm is a challenging variance reduction (VR) technique that has been recently investigated in the field of particle transport simulation. It has been implemented in the forthcoming version 11 of the Monte Carlo code TRIPOLI-4{sup R} and successfully tested in neutron-only and photon-only configurations. This paper addresses the application of the AMS algorithm to coupled simulations, and particularly to neutron-photon Monte Carlo calculations. The branching process occurring during the Monte Carlo coupled transport is taken into account in the new coupled-AMS algorithm and is explained in this paper. Two different neutron-photon configurations are then investigated, leading to a comparison of the coupled-AMS algorithm with the analog simulation on the one hand, and with the Exponential Transform (ET) on the other hand, which is the standard VR technique of TRIPOLI-4. Gains up to 30 are obtained in terms of Figure of Merit relatively to the analog simulation, which is about 4 to 6 times more efficient than the ET method for these configurations. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental and Numerical Investigation of Propellant of Different Thickness for Laser Micro Propulsion

The thickness of propellant is an important experimental parameter under T-mode, which has a direct impact on the performance of the laser Micro propulsion. In this paper, the prolusion performance of four propellants with different thickness is measured respectively, the experimental results show that the momentum coupling coefficient C{sub m} rises with the increase of thickness, while the specific impulse I{sub sp} falls on the contrary. The same trend for I{sub sp} also has been obtained from the simulated result by the Discrete Element Program (DEM).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Engine Cycle Analysis of Air Breathing Microwave Rocket with Reed Valves

The Microwave Rocket is a candidate for a low cost launcher system. Pulsed plasma generated by a high power millimeter wave beam drives a blast wave, and a vehicle acquires impulsive thrust by exhausting the blast wave. The thrust generation process of the Microwave Rocket is similar to a pulse detonation engine. In order to enhance the performance of its air refreshment, the air-breathing mechanism using reed valves is under development. Ambient air is taken to the thruster through reed valves. Reed valves are closed while the inside pressure is high enough. After the time when the shock wave exhausts at the open end, an expansion wave is driven and propagates to the thrust-wall. The reed valve is opened by the negative gauge pressure induced by the expansion wave and its reflection wave. In these processes, the pressure oscillation is important parameter. In this paper, the pressure oscillation in the thruster was calculated by CFD combined with the flux through from reed valves, which is estimated analytically. As a result, the air-breathing performance is evaluated using Partial Filling Rate (PFR), the ratio of thruster length to diameter L/D, and ratio of opening area of reed valves to superficial area {alpha}. An engine cycle and predicted thrust was explained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-97: An Analysis of Knowledge Based Planning for Stereotactic Body Radiation Therapy of the Spine

Purpose: Creating high quality SBRT treatment plans for the spine is often tedious and time consuming. In addition, the quality of treatment plans can vary greatly between treatment facilities due to inconsistencies in planning methods. This study investigates the performance of knowledge-based planning (KBP) for spine SBRT. Methods: Treatment plans were created for 28 spine SBRT patients. Each case was planned to meet strict dose objectives and guidelines. After physician and physicist approval, the plans were added to a custom model in a KBP system (RapidPlan, Varian Eclipse v13.5). The model was then trained to be able to predict estimated DVHs and provide starting objective functions for future patients based on both generated and manual objectives. To validate the model, ten additional spine SBRT cases were planned manually as well as using the model objectives. Plans were compared based on planning time and quality (ability to meet the plan objectives, including dose metrics and conformity). Results: The average dose to the spinal cord and the cord PRV differed between the validation and control plans by <0.25% demonstrating iso-toxicity. Six out of 10 validation plans met all dose objectives without the need for modifications, and overall, target dose coverage was increased by about 4.8%. If the validation plans did not meet the dose requirements initially, only 1–2 iterations of modifying the planning parameters were required before an acceptable plan was achieved. While manually created plans usually required 30 minutes to 3 hours to create, KBP can be used to create similar quality plans in 15–20 minutes. Conclusion: KBP for spinal tumors has shown to greatly decrease the amount of time required to achieve high quality treatment plans with minimal human intervention and could feasibly be used to standardize plan quality between institutions. Supported by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Beam Test Results of the RADiCAL—A Radiation Hard Innovative EM Calorimeter

High-performance calorimetry conducted at future hadron colliders, such as the FCC-hh, poses a significant challenge for applying current detector technologies due to unprecedented beam luminosities and radiation fields. Solutions include developing scintillators that are capable of separating events at the sub-fifty picosecond level while also maintaining performance after extreme and constant neutron and ionizing radiation exposure. The radiation-hard innovative calorimeter (RADiCAL) is an approach that incorporates radiation tolerant materials in a sampling “shashlik”-style calorimeter configuration, using quartz capillaries filled with organic liquid or polymer-based wavelength shifters embedded in layers of tungsten plates and lutetium-yttrium oxyorthosilicate (LYSO) crystals. Here, this novel design intends to address the priority research directions (PRD) for calorimetry listed in the DOE basic research needs (BRN) workshop for high energy physics (HEP) instrumentation. Here we report preliminary results from an experimental run at the Fermilab Test Beam Facility (FTBF) in June 2022. These tests demonstrate that the RADiCAL concept is capable of ¡50 ps timing resolution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time Evolution of Electric Fields in CDMS Detectors

The Cryogenic Dark Matter Search (CDMS) utilizes large mass, 3-inch diameter x 1-inch thick target masses as particle detectors. The target is instrumented with both phonon and ionization sensors, the later providing a {approx}1 V cm{sup -1} electric field in the detector bulk. Cumulative radiation exposure which creates {approx}200 x 10{sup 6} electron-hole pairs could be sufficient to produce a comparable reverse field in the detector thereby degrading the ionization channel performance, if it was not shielded by image charges on the electrodes. To study this, the existing CDMS detector Monte Carlo has been modified to allow for an event by event evolution of the bulk electric field, in three spatial dimensions. Surprisingly, this simple model is not sufficient to explain the degradation of detector performance. Our most recent results and interpretation are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Characterization of Scintillator Performance at Temperatures up to 400 Degrees Centigrade

The logging and characterization of geothermal wells requires improved scintillator systems that are capable of operation at temperatures significantly above those commonly encountered in the logging of most conventional oil and gas wells (e.g., temperatures nominally in the range of up to 150oC.) Unfortunately, most of the existing data on the performance of scintillators for radiation detection at elevated temperatures is fragmentary, uncorrelated, and generally limited to relatively low temperatures in most cases to temperatures well below 200oC. We have designed a system for characterizing scintillator performance at temperatures extending up to 400oC under inert atmospheric conditions, and this system is applied here to the determination of scintillator performance at elevated temperatures for a wide range of scintillators including, among others: bismuth germanate, cadmium tungstate, cesium iodide, cesium iodide (Tl), cesium iodide (Na), sodium iodide, sodium iodide (Tl), lutetium oxy-orthosilicate (Ce), zinc tungstate, yttrium aluminum perovskite (Ce), yttrium aluminum garnet (Ce), lutetium aluminum perovskite (Ce), and barium fluoride, strontium iodide(Eu). The results of these high-temperature scintillator performance tests are described in detail here. Comparisons of the relative elevated-temperature properties of the various scintillator materials have resulted in the identification of promising scintillator candidates for high-temperature use in geothermal and fossil-fuel well environments.

gamma ray↗

Characterizing plasma conditions in radiatively heated solid-density samples with x-ray Thomson scattering

Here, we have developed an experimental platform to generate radiatively heated solid density samples for warm dense matter studies at the OMEGA laser facility. Cylindrical samples of boron and beryllium are isochorically heated by K- and L-shell emission from x-ray converter foils wrapped around the cylinders' radii. X-ray Thomson scattering (XRTS) measures the temperature and the ionization state of the samples as function of time. Temperatures approach 10 eV, and the ionization states are found to be Z B = 3 and Z Be = 2. Radiation hydrodynamics simulations were performed to confirm a homogeneous plasma state exists in the center of the sample for the duration of the experiment. Results from the study can be extended to improve understanding of radiative heating processes in the warm dense matter regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of detector grade CdZnTe material from Redlen Technologies

CdZnTe (or CZT) crystals can be used in a variety of detector-type applications. This large band gap material shows great promise for use as a gamma radiation spectrometer. Historically, the performance of CZT has typically been adversely affected by point defects, structural and compositional heterogeneities within the crystals, such as twinning, pipes, grain boundaries (polycrystallinity) and secondary phases (SP). The synthesis of CZT material has improved greatly with the primary performance limitation being attributed to mainly SP. In this presentation, we describe the extensive characterization of detector grade material that has been treated with post growth annealing to remove the SPs. Some of the analytical methods used in this study included polarized, cross polarized and transmission IR imaging, I-V curves measurements, synchrotron X-ray topography and electron microscopy.

43 PARTICLE ACCELERATORS↗