Search NASA⌕ Search

SEARCH · Search NASA

Results for “SWEEP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

High-resolution thermal expansion measurements under helium-gas pressure

We report on the realization of a capacitive dilatometer, designed for high-resolution measurements of length changes of a material for temperatures 1.4 K Less-Than-Or-Slanted-Equal-To T Less-Than-Or-Slanted-Equal-To 300 K and hydrostatic pressure P Less-Than-Or-Slanted-Equal-To 250 MPa. Helium ({sup 4}He) is used as a pressure-transmitting medium, ensuring hydrostatic-pressure conditions. Special emphasis has been given to guarantee, to a good approximation, constant-pressure conditions during temperature sweeps. The performance of the dilatometer is demonstrated by measurements of the coefficient of thermal expansion at pressures P Asymptotically-Equal-To 0.1 MPa (ambient pressure) and 104 MPa on a single crystal of azurite, Cu{sub 3}(CO{sub 3}){sub 2}(OH){sub 2}, a quasi-one-dimensional spin S = 1/2 Heisenberg antiferromagnet. The results indicate a strong effect of pressure on the magnetic interactions in this system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Revisiting plasma hysteresis with an electronically compensated Langmuir probe

The measurement of electron temperature in plasma by Langmuir probes, using ramped bias voltage, is seriously affected by the capacitive current of capacitance of the cable between the probe tip and data acquisition system. In earlier works a dummy cable was used to balance the capacitive currents. Under these conditions, the measured capacitive current was kept less than a few mA. Such probes are suitable for measurements in plasma where measured ion saturation current is of the order of hundreds of mA. This paper reports that controlled balancing of capacitive current can be minimized to less than 20 {mu}A, allowing plasma measurements to be done with ion saturation current of the order of hundreds of {mu}A. The electron temperature measurement made by using probe compensation technique becomes independent of sweep frequency. A correction of {<=}45% is observed in measured electron temperature values when compared with uncompensated probe. This also enhances accuracy in the measurement of fluctuation in electron temperature as {delta}T{sub pk-pk} changes by {approx}30%. The developed technique with swept rate {<=}100 kHz is found accurate enough to measure both the electron temperature and its fluctuating counterpart. This shows its usefulness in measuring accurately the temperature fluctuations because of electron temperature gradient in large volume plasma device plasma with frequency ordering {<=}50 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Langmuir probe diagnostics of an atmospheric pressure, vortex-stabilized nitrogen plasma jet

Langmuir probe measurements in an atmospheric pressure direct current (dc) plasma jet are reported. Sweeping probes were used. The experiment was carried out using a dc non-transferred arc torch with a rod-type cathode and an anode of 5 mm diameter. The torch was operated at a nominal power level of 15 kW with a nitrogen flow rate of 25 Nl min{sup -1}. A flat ion saturation region was found in the current-voltage curve of the probe. The ion saturation current to a cylindrical probe in a high-pressure non local thermal equilibrium (LTE) plasma was modeled. Thermal effects and ionization/recombination processes inside the probe perturbed region were taken into account. Averaged radial profiles of the electron and heavy particle temperatures as well as the electron density were obtained. An electron temperature around 11 000 K, a heavy particle temperature around 9500 K and an electron density of about 4 Multiplication-Sign 10{sup 22} m{sup -3}, were found at the jet centre at 3.5 mm downstream from the torch exit. Large deviations from kinetic equilibrium were found throughout the plasma jet. The electron and heavy particle temperature profiles showed good agreement with those reported in the literature by using spectroscopic techniques. It was also found that the temperature radial profile based on LTE was very close to that of the electrons. The calculations have shown that this method is particularly useful for studying spraying-type plasma jets characterized by electron temperatures in the range 9000-14 000 K.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Contamination effects on fixed-bias Langmuir probes

Langmuir probes are standard instruments for plasma density measurements on many sounding rockets. These probes can be operated in swept-bias as well as in fixed-bias modes. In swept-bias Langmuir probes, contamination effects are frequently visible as a hysteresis between consecutive up and down voltage ramps. This hysteresis, if not corrected, leads to poorly determined plasma densities and temperatures. With a properly chosen sweep function, the contamination parameters can be determined from the measurements and correct plasma parameters can then be determined. In this paper, we study the contamination effects on fixed-bias Langmuir probes, where no hysteresis type effect is seen in the data. Even though the contamination is not evident from the measurements, it does affect the plasma density fluctuation spectrum as measured by the fixed-bias Langmuir probe. We model the contamination as a simple resistor-capacitor circuit between the probe surface and the plasma. We find that measurements of small scale plasma fluctuations (meter to sub-meter scale) along a rocket trajectory are not affected, but the measured amplitude of large scale plasma density variation (tens of meters or larger) is attenuated. From the model calculations, we determine amplitude and cross-over frequency of the contamination effect on fixed-bias probes for different contamination parameters. The model results also show that a fixed bias probe operating in the ion-saturation region is affected less by contamination as compared to a fixed bias probe operating in the electron saturation region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-linear magnetohydrodynamic simulations of density evolution in Tore Supra sawtoothing plasmas

The plasma density evolution in sawtooth regime on the Tore Supra tokamak is analyzed. The density is measured using fast-sweeping X-mode reflectometry which allows tomographic reconstructions. There is evidence that density is governed by the perpendicular electric flows, while temperature evolution is dominated by parallel diffusion. Postcursor oscillations sometimes lead to the formation of a density plateau, which is explained in terms of convection cells associated with the kink mode. A crescent-shaped density structure located inside q = 1 is often visible just after the crash and indicates that some part of the density withstands the crash. 3D full MHD nonlinear simulations with the code XTOR-2F recover this structure and show that it arises from the perpendicular flows emerging from the reconnection layer. The proportion of density reinjected inside the q = 1 surface is determined, and the implications in terms of helium ash transport are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-harmonic RF test stand for RF breakdown studies

A multi-harmonic RF test stand is under construction at Yale Beam Physics Laboratory. It includes a frequency multiplier which can generate high power harmonics efficiently that are phase locked to the fundamental drive frequency. In a bi-modal asymmetric cavity powered by this RF source, the cavity may experience reduced exposure time to peak fields and sweeping of peak fields across their surfaces, and strong asymmetry between surfaces that may experience cathode-and anode-like fields; these phenomena are to be assessed for their influence on RF breakdown probabilities.

43 PARTICLE ACCELERATORS↗

Nonideal fishbone instability excited by trapped energetic electrons

It is shown that trapped energetic electrons can resonate with the collisionless m = 1 nonideal kink mode, therefore exciting the nonideal e-fishbone, which would often lead to a drop in soft x-ray emissivity and frequency chirping. The theory predictions agree well with the experimental observations of e-fishbone on HL-2A. It is also found that the effects of MHD energy of background plasma might be the reason for the observed phenomena: frequency chirping up and down, and V-font-style sweeping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

All-silicon Michelson instrument on chip: Distance and surface profile measurement and prospects for visible light spectrometry

A miniature Michelson interferometer is analyzed theoretically and experimentally. The fabricated micro-interferometer is incorporated at the tip of a monolithic silicon probe to achieve contactless distance measurements and surface profilometry. For infrared operation, two approaches are studied, based on the use of monochromatic light and wavelength sweep, respectively. A theoretical model is devised to depict the system characteristics taking into account Gaussian beam divergence and light spot size. Furthermore, preliminary results using visible light demonstrate operation of the probe as a visible light spectrometer, despite silicon absorbance, thanks to the micrometer thickness involved in the beam splitter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing the local surface potential and quantum capacitance in single and multi-layer graphene

We report on local measurements of the surface potential and quantum capacitance in single layer graphene as well as multilayers thereof as a function of the carrier density by using frequency-modulated Kelvin probe force microscopy. We find excellent agreement to tight-binding calculations reported for graphene monolayers and extract the minimum quantum capacitance from density sweeps at room temperature. The surface potential of graphene multilayers is found to depend linearly on the carrier density, which suggests treating them as two-dimensional electron gases. In addition, we demonstrate that the simultaneously detected second harmonic of the Kelvin modulation, proportional to |∂{sup 2}C/∂z{sup 2}|, is directly sensitive to local changes in the quantum capacitance of graphene.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A 4 K cryogenic probe for use in magnetic resonance force microscopy experiments

The detailed design of a mechanically detected nuclear magnetic resonance probe using the SPAM (Springiness Preservation by Aligning Magnetization) geometry, operating at 4 K, in vacuum, and a several-Tesla magnetic field is described. The probe head is vibration-isolated well enough from the environment by a three-spring suspension system that the cantilever achieves thermal equilibrium with the environment without the aid of eddy current damping. The probe uses an ultra-soft Si cantilever with a Ni sphere attached to its tip, and magnetic resonance is registered as a change in the resonant frequency of the driven cantilever. The RF system uses frequency sweeps for adiabatic rapid passage using a 500 μm diameter RF coil wound around a sapphire rod. The RF coil and optical fiber of the interferometer used to sense the cantilever's position are both located with respect to the cantilever using a Garbini micropositioner, and the sample stage is mounted on an Attocube nanopositioner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-energy inverse photoemission spectroscopy using a high-resolution grating spectrometer in the near ultraviolet range

An inverse photoemission spectroscopy (IPES) apparatus using a Czerny-Turner grating spectrometer is demonstrated. Previous IPES instruments based on grating spectrometers used a concave grating and operated in the vacuum ultraviolet range. The reflectance of such gratings is lower than 20% and the aberration cannot be finely corrected leading to an energy resolution of up to 0.1 eV. In the present study, employing the low energy IPES regime [H. Yoshida, Chem. Phys. Lett. 539–540, 180 (2012)], incident electrons with a kinetic energy below 5 eV are used, while photon emission in the range of between 250 and 370 nm is analyzed with a 10-cm Czerny-Turner grating spectrometer. The signal intensity is at least 30 times higher than the previous apparatus. The resolution of photon detection is set at 0.07 eV though the ultimate resolution is one order of magnitude higher. The experiment is performed both by sweeping the electron energy (isochromat mode) and by simultaneously analyzing the photon of whole wavelength range (tunable photon energy mode)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanopatterning and tuning of optical taper antenna apex for tip-enhanced Raman scattering performance

This paper focuses on finding optimal electrochemical conditions from linear sweep voltammetry analysis for preparing highly reproducible tip-enhanced Raman scattering (TERS) conical gold tips with dc-pulsed voltage etching. Special attention is given to the reproducibility of tip apex shapes with different etchant mixtures. We show that the fractional Brownian motion model enables a mathematical description of the decaying current kinetics during the whole etching process up to the cutoff event. Further progress in preparation of highly reproducible smooth and sharp tip apexes is related to the effect of an additive, such as isopropanol, to aqueous acids. A finite-difference time-domain method based near-field analysis provides evidence that TERS performance depends critically on tip orientation relative to a highly focused laser beam. A TERS based criterion for recognizing gold tips able to couple/decouple optical near- and far-fields is proposed.

36 MATERIALS SCIENCE↗

An innovative tri-directional broadband piezoelectric energy harvester

This paper presents a tri-directional piezoelectric energy harvester that is able to harvest vibration energy over a wide bandwidth from three orthogonal directions. The harvester consists of a main beam, an auxiliary beam, and a spring-mass system, with magnets integrated to introduce nonlinear force and couple the three sub-systems. Theoretical analysis and experiments were performed at constant acceleration under frequency sweeps to acquire frequency responses. The experimental results show that the voltage can achieve more than 2 V over more than 5 Hz of bandwidth with 1 MΩ load in the three orthogonal directions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-resolved measurement of plasma parameters by means of triple probe

Triple Langmuir probe (TLP) diagnostic system with its necessary driving circuit is developed and successfully applies for time-resolved measurement of plasma parameters in the negative glow region of pulsating-dc discharge. This technique allows the instantaneous measurement of electron temperature [T{sub −}], electron number density [n{sub −}] as well as plasma fluctuations without any voltage or frequency sweep. In TLP configuration two probes are differentially biased and serve as a floating symmetric double probe whereas the third probe is simply floating into plasma to measure floating potential as a function of time and thus incorporates the effect of plasma fluctuations. As an example of the application to time-dependent plasmas, basic plasma parameters such as floating potential, electron temperature, and electron number density in low pressure air discharge are determined as a function of time for different fill pressure. The results demonstrate temporal evolution of plasma parameters and thus plasma generation progression for different fill pressures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recovery of oscillatory magneto-resistance in phase separated La{sub 0.3}Pr{sub 0.4}Ca{sub 0.3}MnO{sub 3} epitaxial thin films

In-plane angular dependent magneto-resistance has been studied in La{sub 0.3}Pr{sub 0.4}Ca{sub 0.3}MnO{sub 3} (LPCMO) manganite thin films deposited on the (100) oriented NdGaO{sub 3}, and (001) oriented SrTiO{sub 3} and LaAlO{sub 3} substrates. At temperatures where the electronic phase separation is the strongest, a metastable irreversible state exists in the films whose resistivity ρ attains a large time dependent value. The ρ decreases sharply with an increasing angle θ between the magnetic field and the current, and does not display an expected oscillatory cos{sup 2}θ/sin{sup 2}θ dependence for all films. The regular oscillations are recovered during repetitive sweeping of θ between 0° and 180°. We discuss possible factors that could produce these unusual changes in the resistivity.

36 MATERIALS SCIENCE↗

Development of radon sources with a high stability and a wide range

A solid {sup 222}Rn (radon) source using a fibrous and porous SiC ceramic disk was developed. The emission rate of radon emanated from the disk depended on the content of {sup 226}Ra and the sintering temperature. A {sup 226}Ra sulfate ({sup 226}RaSO{sub 4}) solution was dropped on a fibrous SiC ceramic disk (33 mmφ) of 1 mm in thickness, and sintered at 400 °C. The radon concentration from a disk containing {sup 226}Ra of 1.85 MBq was measured to be 38 kBq m{sup −3} at a carrier airflow rate of 0.5 L min{sup −1}. By adjusting the {sup 226}Ra content or the sweep airflow rate, the radon concentrations were easily controlled over a wide range of over three orders of magnitude. The concentration was very stable for a long term. The compactness of the source disk made is easy for handling the source container and the shielding of gamma radiation from {sup 226}Ra and its decay products. Such advantages in a radon generation system are desirable for experiments of high-level, large-scale radon exposure.

07 ISOTOPE AND RADIATION SOURCES↗

Hyperfine-induced hysteretic funnel structure in spin blockaded tunneling current of coupled vertical quantum dots at low magnetic field

We outline the properties of the hyperfine-induced funnel structure observed in the two-electron spin blockade region of a weakly coupled vertical double quantum dot device. Hysteretic steps in the leakage current occur due to dynamic nuclear polarization when either the bias voltage or the magnetic field is swept up and down. When the bias voltage is swept, an intriguing ∼3 mT wide cusp near 0 T appears in the down-sweep position, and when the magnetic field is swept, the current at 0 T can be switched from 'low' to 'high' as the bias is increased.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Locating an individual quantum hall island inside a quantum ring

Scanning gate microscopy is used to find the position of a quantum Hall island (QHI) which controls the electron transport through a mesoscopic quantum ring. Such QHIs emerging around potential inhomogeneities are tunnel-coupled with edge states. Approaching a polarized metallic tip over the QHIs gradually changes their surface and generates Coulomb blockade oscillations. This mechanism permits the identification of the center of the QHIs. Here, by sweeping the distance between the tip and the two dimensional electron gas, we clearly locate the center of an individual QHI.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗