Search NASA⌕ Search

SEARCH · Search NASA

Results for “Storage systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Automatic Identification of Application I/O Signatures from Noisy Server-Side Traces

Competing workloads on a shared storage system cause I/O resource contention and application performance vagaries. This problem is already evident in today s HPC storage systems and is likely to become acute at exascale. We need more interaction between application I/O requirements and system software tools to help alleviate the I/O bottleneck, moving towards I/O-aware job scheduling. However, this requires rich techniques to capture application I/O characteristics, which remain evasive in production systems. Traditionally, I/O characteristics have been obtained using client-side tracing tools, with drawbacks such as non-trivial instrumentation/development costs, large trace traffic, and inconsistent adoption. We present a novel approach, I/O Signature Identifier (IOSI), to characterize the I/O behavior of data-intensive applications. IOSI extracts signatures from noisy, zero-overhead server-side I/O throughput logs that are already collected on today s supercomputers, without interfering with the compiling/execution of applications. We evaluated IOSI using the Spider storage system at Oak Ridge National Laboratory, the S3D turbulence application (running on 18,000 Titan nodes), and benchmark-based pseudo-applications. Through our ex- periments we confirmed that IOSI effectively extracts an application s I/O signature despite significant server-side noise. Compared to client-side tracing tools, IOSI is transparent, interface-agnostic, and incurs no overhead. Compared to alternative data alignment techniques (e.g., dynamic time warping), it offers higher signature accuracy and shorter processing time.

Liu, Yang↗

A Hybrid Fuel Cell and Battery Storage Power Management for Grid-Interactive EV Charging Station

With the increasing adoption of renewable energy sources in grid-interactive Electric Vehicle (EV) charging stations, the role of energy storage systems has become critical. While large energy storage systems have mitigated the intermittency of renewable energy, integrating multi-source energy management with prioritized charging can further enhance the reliability of charging stations (CS). This paper presents a decentralized energy management (DEM) approach combining battery energy storage (BES) and fuel cell (FC) systems using a rule-based line resistance correction droop (LRCD) control technique. The proposed droop control dynamically adjusts the gain to balance the state-of-charge (SoC) of the BES, enhancing power support longevity and improving battery life under varying capacity conditions by reducing current stress. Additionally, the paper addresses the challenges of using fuel cells in linear regions to optimize efficiency and manage various charging scenarios. The CS integrates unity power factor grid interaction, and power support for auxiliary loads, maintaining harmonic distortion within 5% during grid islanding. The approach evaluates DC bus voltage regulation under various scenarios of PV array power fluctuations and dynamic load variations, in both grid-connected and standalone operations. In conclusion, the proposed control strategy is validated on a laboratory prototype through various dynamic load variation and grid islanding scenarios.

Khalid, Mohd [Oak Ridge National Laboratory (ORNL)↗

A hierarchical framework for aggregating grid-interactive buildings with thermal and battery energy storage

The behind-the-meter (BTM) thermal and battery energy storage can help improve energy efficiency, reduce energy costs, and enhance energy resilience, particularly in rural areas and for disadvantaged communities. Aggregating numerous BTM energy storage systems can act as a price influencer with a significant source of load shifting and peak demand reduction. An integrated and scalable control mechanism is required to effectively utilize energy storage systems and flexible building loads to maximize the economic benefits, considering various distribution system constraints. Here, this paper presents an innovative hierarchical coordination framework for energy storage and flexible load in buildings, considering various factors such as electricity prices, thermal comfort, and distribution system modeling and constraints. At the upper level, a distribution system operator optimizes the power flow to minimize its power procurement costs from the electricity wholesale market, while at the lower level, aggregators determine the optimal dispatch of battery and thermal energy storage systems in multiple buildings on behalf of end-users to minimize operating costs according to the power prices. These problems are solved using a game-theoretic approach through negotiations between the distribution system operator and aggregators as a bi-level decision model. Simulation case studies have been performed for a test distribution network with a number of building end-users using energy storage systems to quantify the performance of aggregators. The results demonstrate that the proposed strategy can reduce peak load for a reliable electricity distribution network while saving electricity bills for customers.

25 ENERGY STORAGE↗

Energy Conversion and Storage Requirements for Hybrid Electric Aircraft

Among various options for reducing greenhouse gases in future large commercial aircraft, hybrid electric option holds significant promise. In the hybrid electric aircraft concept, gas turbine engine is used in combination with an energy storage system to drive the fan that propels the aircraft, with gas turbine engine being used for certain segments of the flight cycle and energy storage system being used for other segments. The paper will provide an overview of various energy conversion and storage options for hybrid electric aircraft. Such options may include fuel cells, batteries, super capacitors, multifunctional structures with energy storage capability, thermoelectric, thermionic or a combination of any of these options. The energy conversion and storage requirements for hybrid electric aircraft will be presented. The role of materials in energy conversion and storage systems for hybrid electric aircraft will be discussed.

Energy Conversion↗

Reference Station Design for Heavy-Duty Vehicles

Five alternative design configurations for a heavy-duty hydrogen refueling truck stop are detailed in this work. Each of the station concepts provides fast, 5-minute, 50 kg fills of up to 4 vehicles simultaneously, with a station capacity of 4200 kg/day. Two on-site production stations using PEM electrolysis are considered: one with off-peak production of the daily capacity; and one with on-demand production of hydrogen during vehicle refueling. Three delivered liquid hydrogen station concepts are considered: one with the same, high-pressure cascade storage system for dispensing as the electrolysis supplied stations, with low-pressure vaporization of the liquid hydrogen and pressurization via a compressor; and two with on-demand pressurization: one by low-pressure vaporization and compressors; and one with a cryogenic pump and high-pressure vaporization. Design, economic, and operational considerations for each of the components needed in these station concepts is provided. Of all the station concepts, the delivered liquid station with a low-pressure vaporizer and a cascade dispensing system has the lowest capital costs and equipment footprint, but the second highest operating costs primarily due to high costs for liquid hydrogen delivery. The lowest operating cost station is that with on-site production via PEM electrolysis at off-peak hours with a cascade delivery system. The low-pressure buffer storage system and electrolyzers have a large footprint and considerable capital costs, but could result in a low total cost of ownership, depending on the design timeline. The liquid hydrogen station with a cryo-pump has moderate capital costs, the lowest operating costs of the three delivered hydrogen stations, and the same small equipment footprint as the delivered liquid, cascade dispensing system. As cryogenic pumping technology improves and the capital costs for these pumps decreases, this station concept will become even more favorable. Three-dimensional renderings of the five station concepts provide station designers with a starting point for the development of heavy-duty refueling stations.

08 HYDROGEN↗

Fraction-storage unit for drug-identification system

Device, connecting outputs of all gas chromatographs to single, relatively inexpensive IR spectrometer, reduces costs of system. Storage unit provides buffer storage of samples until infrared spectrometer is ready to accept them. Storage unit can be used to separate overlapping peaks.

Campen, C. F.↗

Data archiving

The viewgraphs of a discussion on data archiving presented at the National Space Science Data Center (NSSDC) Mass Storage Workshop is included. The mass storage system at the National Center for Atmospheric Research (NCAR) is described. Topics covered in the presentation include product goals, data library systems (DLS), client system commands, networks, archival devices, DLS features, client application systems, multiple mass storage devices, and system growth.

Pitts, David↗

Thermal energy storage devices, systems, and methods

Methods, systems, and device for thermal energy storage are provided. For example, some embodiments include a thermal energy storage device that may include: a first casing wall; a second casing wall; and/or multiple support structures located between the first casing wall and the second casing wall. The multiple support structures may provide continuous thermal paths and/or continuous mechanical paths between the first casing wall and the second casing wall. The thermal energy storage device may be fabricated utilizing an additive manufacturing technique, such as direct laser metal sintering. Some embodiments may be manufactured utilizing printed metals, such as an aluminum alloy. In some embodiments, a phase-change material is charged between the first casing wall and the second casing wall. The phase-change material may include paraffin.

Isaacs, Steven↗

Energy storage considerations for a robotic Mars surface sampler

The characteristics of various energy storage systems (including Ni-Cd, Ni-H2, Ag-Zn, Li-XS, Na-S, PbSO4, and regenerative fuel cell systems) considered for a robotic Mars surface sampler are reviewed. It is concluded that the bipolar nickel-hydrogen battery and the sodium-sulfur battery are both viable candidates as storage systems for the rover's Radioisotope Thermoelectric Generator. For a photovoltaic storage system, the regenerative fuel cell and the bipolar nickel-hydrogen battery are the primary candidates.

O'Donnell, P. M.↗

Pufferscale: Rescaling HPC Data Services for High Energy Physics Applications

User-space HPC data services are emerging as an appealing alternative to traditional parallel file systems, because of their ability to be tailored to application needs while eliminating unnecessary overheads incurred by POSIX compliance. The High Energy Physics (HEP) community is progressively turning towards such services to enable high-throughput accesses under heavy concurrency to billions of event data produced by instruments and consumed by subsequent analysis workflows. Such services would benefit from the possibility to be rescaled up and down to adapt to changing workloads, as experimental campaigns progress, in order to optimize resource usage. This paper formalizes rescaling a distributed storage system as a multi objective optimization problem considering three criteria: load balance, data balance, and duration of the rescaling operation. We propose a heuristic for rapidly finding a good approximate solution, while allowing users to weight the criteria as needed. The heuristic is evaluated with Pufferscale, a new rescaling manager for microservice-based distributed storage systems. To validate our approach in a real-world ecosystem, we showcase the use of Pufferscale as a means to enable storage malleability in the HEPnOS storage system for HEP applications.

Distributed Storage System↗

Baseline Testing of the Club Car Carryall With Asymmetric Ultracapacitors

The NASA John H. Glenn Research Center initiated baseline testing of the Club Car Carryall with asymmetric ultracapacitors as a way to reduce pollution in industrial settings, reduce fossil fuel consumption, and reduce operating costs for transportation systems. The Club Car Carryall provides an inexpensive approach to advance the state of the art in electric vehicle technology in a practical application. The project transfers space technology to terrestrial use via non-traditional partners, and provides power system data valuable for future space applications. The work was done under the Hybrid Power Management (HPM) Program, which includes the Hybrid Electric Transit Bus (HETB). The Carryall is a state of the art, ground up, electric utility vehicle. A unique aspect of the project was the use of a state of the art, long life ultracapacitor energy storage system. Innovative features, such as regenerative braking through ultracapacitor energy storage, are planned. Regenerative braking recovers much of the kinetic energy of the vehicle during deceleration. The Carryall was tested with the standard lead acid battery energy storage system, as well as with an asymmetric ultracapacitor energy storage system. The report concludes that the Carryall provides excellent performance, and that the implementation of asymmetric ultracapacitors in the power system can provide significant performance improvements.

Eichenberg, Dennis J.↗

XRootD Third Party Copy for the WLCG and HLLHC

A Third Party Copy (TPC) mechanism has existed in the pure XRootD storage environment for many years. However, using the XRootD TPC in the WLCG environment presents additional challenges due to the diversity of the storage systems involved such as EOS, dCache, DPM and ECHO, requiring that we carefully navigate the unique constraints imposed by these storage systems and their site-specific environments through customized configuration and software development. To support multitenant setups seen at many WLCG sites, X509 based authentication and authorization in XRootD was significantly improved to meet both security and functionality requirements. This paper presents architecture of the pull based TPC with optional X509 credential delegation, and how it is implemented in native XRootD and dCache. The paper discusses technical requirements, challenges, design choices and implementation details in the WLCG storage systems, as well as in FTS/gfal2. It also outlines XRootD’s plan to support newer TPC and security models such as token based authorization.

Adye, T.↗

XRootD Third Party Copy for the WLCG and HL- LHC

A Third Party Copy (TPC) mechanism has existed in the pure XRootD storage environment for many years. However, using the XRootD TPC in the WLCG environment presents additional challenges due to the diversity of the storage systems involved such as EOS, dCache, DPM and ECHO, requiring that we carefully navigate the unique constraints imposed by these storage systems and their site-specific environments through customized configuration and software development. To support multitenant setups seen at many WLCG sites, X509 based authentication and authorization in XRootD was significantly improved to meet both security and functionality requirements. This paper presents architecture of the pull based TPC with optional X509 credential delegation, and how it is implemented in native XRootD and dCache. The paper discusses technical requirements, challenges, design choices and implementation details in the WLCG storage systems, as well as in FTS/gfal2. It also outlines XRootD's plan to support newer TPC and security models such as token based authorization. 1

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enabling High Availability Service with oVirt Virtualization and CephFS

The online computing environment at STAR has generated demand for high availability of services (HAS) and a resilient uptime guarantee. Such services include databases, webservers, and storage systems that user and sub-systems tend to rely on for their critical workflows. Standard deployment of services on bare metal creates a problem if the fundamental hardware fails or loses connectivity. Additionally, the configuration of redundant failover nodes (a secondary Web service for example) requires constant syncing of configuration and content and sometimes manual interaction for switching hardware (DNS name comes to mind). For this project, we will focus on two tools: oVirt and Ceph. oVirt is an OpenSource virtualization management application that enables central management of hardware nodes, storage, and network resources used to deploy and monitor virtual machines. oVirt supports the deployment of a virtual environment for your data center leveraging automatic provisioning, live migration, and the ability to easily scale the number of hypervisors. oVirt enables the use of multiple storage technologies where you can store virtual machines, images, and templates within one or multiple storage systems. STAR's recent efforts focused on deploying a CephFS POSIX compliant distributed storage system, we would enable the ability to couple our Ceph storage with the oVirt virtualization management system. When designing an intricate system for hosting critical services, it is a requirement to circumvent single points of failure. This work will involve the testing and viability of such an approach along with test cases for high availability, live migration, and service on demand.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Co-optimized trading of hybrid wind power plant with retired EV batteries in energy and reserve markets under uncertainties

To be competitive in the electricity markets, various technologies have been reported to increase profits of wind farm owners. Combining battery storage system, wind farms can be operated as conventional power plants which promotes the integration of wind power into the power grid. However, high expenses on batteries keep investors away. Retired EV batteries, fortunately, still have enough capacity to be reused and could be obtained at a low price. In this work, a two-stage optimization of a wind energy retired EV battery-storage system is proposed. The economic performance of the proposed system is examined concerning its participation in the frequency containment normal operation reserve (FCR-N) market and the spot market simultaneously. To account uncertainties in the wind farm output, various electricity market prices, and up/down regulation status, a scenario-based stochastic programming method is used. The sizing of the equipment is optimized on top of daily operations of the hybrid system which formulates a mixed-integer linear programming (MILP) problem. Scenarios are generated with the Monte Carlo simulation (MCS) and Roulette Wheel Mechanism (RWM), which are further reduced with the simultaneous backward method (SBM) to increase computational efficiency. A 21 MW wind farm is selected as a case study. Here, the optimization results show that by integrating with a retired EV battery-storage system (RESS) and a bi-directional inverter, the wind farm can increase its profits significantly when forwarding bids in both of the aforementioned electricity markets.

17 WIND ENERGY↗

Upper Atmosphere Research Satellite (UARS) trade analysis

The Upper Atmosphere Research Satellite (UARS) which will collect data pertinent to the Earth's upper atmosphere is described. The collected data will be sent to the central data handling facility (CDHF) via the UARS ground system and the data will be processed and distributed to the remote analysis computer systems (RACS). An overview of the UARS ground system is presented. Three configurations were developed for the CDHF-RACS system. The CDHF configurations are discussed. The IBM CDHF configuration, the UNIVAC CDHF configuration and the vax cluster CDHF configuration are presented. The RACS configurations, the IBM RACS configurations, UNIVAC RACS and VAX RACS are detailed. Due to the large on-line data estimate to approximately 100 GB, a mass storage system is considered essential to the UARS CDHF. Mass storage systems were analyzed and the Braegan ATL, the RCA optical disk, the IBM 3850 and the MASSTOR M860 are discussed. It is determined that the type of mass storage system most suitable to UARS is the automated tape/cartridge device. Two devices of this type, the IBM 3850 and the MASSTOR MSS are analyzed and the applicable tape/cartridge device is incorporated into the three CDHF-RACS configurations.

Fox, M. M.↗

Using Encapsulated Phase Change Material in Thermal Storage for Baseload Concentrating Solar Power Plants

Terrafore successfully demonstrated and optimized the manufacturing of capsules containing phase-changing inorganic salts. The phase change was used to store thermal energy collected from a concentrating solar-power plant as latent heat. This latent heat, in addition to sensible heat increased the energy density (energy stored per unit weight of salt) by over 50%, thus requiring 40% less salt and over 60% less capsule container. Therefore, the cost to store high-temperature thermal energy collected in a concentrating solar power plant will be reduced by almost 40% or more, as compared to conventional two-tank, sensible-only storage systems. The cost for thermal energy storage (TES) system is expected to achieve the Sun Shot goal of $\$ $15 per kWh(t). Costs associated with poor heat-transfer in phase change materials (PCM) were also eliminated. Although thermal energy storage that relies on the latent heat of fusion of PCM improves energy density by as much as 50%, upon energy discharge the salt freezes and builds on the heat transfer surfaces. Since these salts have low thermal conductivity, large heat-transfer areas, or larger conventional heat-exchangers are needed, which increases costs. By encapsulating PCM in small capsules we have increased the heat transfer area per unit volume of salt and brought the heat transfer fluid in direct contact with the capsules. These two improvements have increased the heat transfer coefficient and boosted heat transfer. The program was successful in overcoming the phenomenon of melt expansion in the capsules, which requires the creation of open volume in the capsules or shell to allow for expansion of the molten salt on melting and is heated above its melting point to 550°C. Under contract with the Department of Energy, Terrafore Inc. and Southwest Research Institute, developed innovative method(s) to economically create the open volume or void in the capsule. One method consists of using a sacrificial polymer coating as the middle layer between the salt prill and the shell material. The selected polymer decomposes at temperatures below the melting point of the salt and forms gases which escape through the pores in the capsule shell thus leaving a void in the capsule. We have demonstrated the process with a commonly used inorganic nitrate salt in a low-cost shell material that can withstand over 10,000 high-temperature thermal cycles, or a thirty-year or greater life in a solar plant. The shell used to encapsulate the salt was demonstrated to be compatible with molten salt heat transfer fluid typically used in CSP plants to temperatures up to 600 °C. The above findings have led to the concept of a cascaded arrangement. Salts with different melting points can be encapsulated using the same recipe and contained in a packed bed by cascading the salt melting at higher melting point at the top over the salt melting at lower melting point towards the bottom of the tank. This cascaded energy storage is required to effectively transfer the sensible heat collected in heat transfer fluids between the operating temperatures and utilize the latent heat of fusion in the salts inside the capsule. Mathematical models indicate that over 90% of the salts will undergo phase change by using three salts in equal proportion. The salts are selected such that the salt at the top of the tank melts at about 15°C below the high operating-temperature, and the salt at the bottom of the tank melts 15°C above the low operating-temperature. The salt in the middle of tank melts in-between the operating temperature of the heat transfer fluid. A cascaded arrangement leads to the capture of 90% of the latent-heat of fusion of salts and their sensible heats. Thus the energy density is increased by over 50% from a sensible-only, two-tank thermal energy storage. Furthermore, the Terrafore cascaded storage method requires only one tank as opposed to the two-tanks used in sensible heat storage. Since heat is transferred from the heat transfer fluid by direct contact with capsules, external heat-exchangers are not required for charging storage. Thus, the cost of the thermal storage system is reduced due to smaller containers and less salt. The optimum salt proportions, their melting temperature and the number of salts in the cascade are determined by raw materials costs and the mathematical model. We estimate the processing cost of the encapsulation to be low, where the major cost of the capsule will be the cost of the phase-change salt(s). Our economic analyses show that the cost of EPCM-TES is about $\$ $17.98 per kWh(t), which is about 40% lower than the $\$ $28.36 per kWh(t) for a two-tank sensible heat TES for a large scale CSP-TES design. Finally, additional improvements in the heat-transfer fluids, currently in development elsewhere will further improve the energy density to achieve the SunShot goal of $\$ $15 per kWh(t).

14 SOLAR ENERGY↗