Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗

The Roles of Oxide Growth and Sub-Surface Facets in Oxygen Evolution Activity of Iridium and Its Impact on Electrolysis

This paper combines density functional theory calculations and electrochemical testing to study activity differences among iridium (Ir) surfaces in the oxygen evolution reaction. Ir metal/hydroxide is significantly more active than Ir oxide, which may be due to oxide skins at the surface weakening O-binding relative to pure metal or oxide surfaces. Here we report a disparity in activity between Ir and Ir oxide in half-cells not observed in single-cells. Extended operation at elevated temperature and potential were found to result in oxide growth, limiting how surface differences affect electrolyzer performance. Comparisons of half- and single-cell testing were used to assess how well rotating disk electrode testing predicts membrane electrode assembly performance and durability. Although oxygen evolution activities in half-cells can translate to single-cells, standard rotating disk electrode test procedures can exaggerate the activity benefit of a metal/hydroxide surface relative to membrane electrode assembly performance under typical operating conditions; it also appears that a half-cell test cannot reasonably accelerate activity loss from continual operation. While a variety of novel catalyst approaches, including alloying, faceting, morphology, and supports can improve oxygen evolution kinetics, these results suggest that Ir surfaces at different oxide states may struggle to improve performance at the device level.

36 MATERIALS SCIENCE↗

Experimental Evaluation of High Performance Integrated Heat Pump

Integrated heat pump (IHP) technology provides significant potential for energy savings and comfort improvement for residential buildings. In this study, we evaluate the performance of a high performance IHP that provides space heating, cooling, and water heating services. Experiments were conducted according to the ASHRAE Standard 206-2013 where 24 test conditions were identified in order to evaluate the IHP performance indices based on the airside performance. Empirical curve fits of the unit s compressor maps are used in conjunction with saturated condensing and evaporating refrigerant conditions to deduce the refrigerant mass flowrate, which, in turn was used to evaluate the refrigerant side performance as a check on the airside performance. Heat pump (compressor, fans, and controls) and water pump power were measured separately per requirements of Standard 206. The system was charged per the system manufacturer s specifications. System test results are presented for each operating mode. The overall IHP performance metrics are determined from the test results per the Standard 206 calculation procedures.

Miller, William A↗

Assessment of the Idaho National Laboratory Hot Fuel Examination Facility Stack Monitoring Site for Compliance with ANSI/HPS N13.1 1999

This document reports on a series of tests to determine whether the location of the air sampling probe in the Hot Fuels Examination Facility (HFEF) heating, ventilation and air conditioning (HVAC) exhaust duct meets the applicable regulatory criteria regarding the placement of an air sampling probe. Federal regulations require that a sampling probe be located in the exhaust stack according to the criteria of the ANSI/HPS N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that is representative of the effluent stream. The tests conducted by PNNL during July 2010 on the HFEF system are described in this report. The sampling probe location is approximately 20 feet from the base of the stack. The stack base is in the second floor of the HFEF, and has a building ventilation stream (limited potential radioactive effluent) as well as a process stream (potential radioactive effluent, but HEPA-filtered) that feeds into it. The tests conducted on the duct indicate that the process stream is insufficiently mixed with the building ventilation stream. As a result, the air sampling probe location does not meet the criteria of the N13.1-1999 standard. The series of tests consists of various measurements taken over a grid of points in the duct cross section at the proposed sampling-probe location. The results of the test series on the HFEF exhaust duct as it relates to the criteria from ANSI/HPS N13.1-1999 are desribed in this report. Based on these tests, the location of the air sampling probe does not meet the requirements of the ANSI/HPS N13.1-1999 standard, and modifications must be made to either the HVAC system or the air sampling probe for compliance. The recommended approaches are discussed and vary from sampling probe modifications to modifying the junction of the two air exhaust streams.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Testing Non-Universal Neutrino Couplings with the Super-Kamiokande Solar Data

We present a phenomenological analysis of the non-universal flavor conserving neutrino couplings in the framework of non-standard neutrino interactions. We use the neutrino scattering off electrons in the Super-Kamiokande solar neutrino data. We show that it is possible to obtain constraints that are complementary to the current bounds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of Serum Total and Free PSA Using Immunoaffinity Depletion Coupled to SRM: Correlation with Clinical Immunoassay Tests

Sandwich immunoassay is the standard technique used in clinical labs for quantifying protein biomarkers for disease detection, monitoring and therapeutic intervention. Albeit highly sensitive, the development of a specific immunoassay is rather time-consuming and associated with extremely high cost due to the requirement for paired immunoaffinity reagents of high specificity. Recently, mass spectrometry-based methods, specifically selected reaction monitoring mass spectrometry (SRM-MS), have been increasingly applied to measure low abundance biomarker candidates in tissue and biofluids, owing to high sensitivity and specificity, simplicity of assay configuration, and great multiplexing capability. In this study, we report for the first time the development of immunoaffinity depletion-based workflows and SRM-MS assays that enable sensitive and accurate quantification of total and free prostate-specific antigen (PSA) in serum without the requirement for specific PSA antibodies. With stable isotope dilution and external calibration, low ng/mL level detection of both total and free PSA was consistently achieved in both PSA-spiked female serum samples and actual patient serum samples. Moreover, comparison of the results obtained when SRM PSA assays and conventional immunoassays were applied to the same samples showed very good correlation (R2 values ranging from 0.90 to 0.99) in several independent clinical serum sample sets, including a set of 33 samples assayed in a blinded test. These results demonstrate that the workflows and SRM assays developed here provide an attractive alternative for reliably measuring total and free PSA in human blood. Furthermore, simultaneous measurement of free and total PSA and many other biomarkers can be performed in a single analysis using high-resolution liquid chromatographic separation coupled with SRM-MS.

59 BASIC BIOLOGICAL SCIENCES↗

A hybrid Monte Carlo, discontinuous Galerkin method for linear kinetic transport equations

Here we present a hybrid method for time-dependent particle transport problems that combines Monte Carlo (MC) estimation with deterministic solutions based on discrete ordinates. For spatial discretizations, the MC algorithm computes a piecewise constant solution and the discrete ordinates use bilinear discontinuous finite elements. From the hybridization of the problem, the resulting problem solved by Monte Carlo is scattering free, resulting in a simple, efficient solution procedure. Between time steps, we use a projection approach to “relabel” collided particles as uncollided particles. In conclusion, from a series of standard 2-D Cartesian test problems we observe that our hybrid method has improved accuracy and reduction in computational complexity of approximately an order of magnitude relative to standard discrete ordinates solutions.

97 MATHEMATICS AND COMPUTING↗

Utilization of microalgae for agricultural runoff remediation and sustainable biofuel production through an integrated biorefinery approach

Generally wastewater such agricultural runoff is considered a nuisance; however, it could be harnessed as a potential source of nutrients like nitrates and phosphates in integrated biorefinery context. In the current study, microalgae Chlorella sp. S5 was used for bioremediation of agricultural runoff and the leftover algal biomass was used as a potential source for production of biofuels in an integrated biorefinery context. The microalgae Chlorella sp. S5 was cultivated on Blue Green (BG 11) medium and a comprehensive optimization of different parameters including phosphates, nitrates, and pH was carried out to acquire maximum algal biomass enriched with high lipids content. Dry biomass was quantified using the solvent extraction technique, while the identification of nitrates and phosphates in agricultural runoff was carried out using commercial kits. The algal extracted lipids (oils) were employed in enzymatic trans-esterification for biodiesel production using whole-cell biomass of Bacillus subtilis Q4 MZ841642. The resultant fatty acid methyl esters (FAMEs) were analyzed using Fourier transform infrared (FTIR) spectroscopy and gas chromatography coupled with mass spectrometry (GC–MS). Subsequently, both the intact algal biomass and its lipid-depleted algal biomass were used for biogas production within a batch anaerobic digestion setup. Interestingly, Chlorella sp. S5 demonstrated a substantial reduction of 95% in nitrate and 91% in phosphate from agricultural runoff. The biodiesel derived from algal biomass exhibited a noteworthy total FAME content of 98.2%, meeting the quality standards set by American Society for Testing and Materials (ASTM) and European union (EU) standards. Furthermore, the biomethane yields obtained from whole biomass and lipid-depleted biomass were 330.34 NmL/g VS added and 364.34 NmL/g VS added , respectively. In conclusion, the findings underscore the potent utility of Chlorella sp. S5 as a multi-faceted resource, proficiently employed in a sequential cascade for treating agricultural runoff, producing biodiesel, and generating biogas within the integrated biorefinery concept.

09 BIOMASS FUELS↗

Validation Study of Unnotched Charpy and Taylor-Anvil Impact Experiments using Kayenta

Validation of a single computational model with multiple available strain-to-failure fracture theories is presented through experimental tests and numerical simulations of the standardized unnotched Charpy and Taylor-anvil impact tests, both run using the same material model (Kayenta). Unnotched Charpy tests are performed on rolled homogeneous armor steel. The fracture patterns using Kayenta’s various failure options that include aleatory uncertainty and scale effects are compared against the experiments. Other quantities of interest include the average value of the absorbed energy and bend angle of the specimen. Taylor-anvil impact tests are performed on Ti6Al4V titanium alloy. The impact speeds of the specimen are 321 m/s and 393 m/s. The goal of the numerical work is to reproduce the damage patterns observed in the laboratory. For the numerical study, the Johnson-Cook failure model is used as the ductile fracture criterion, and aleatory uncertainty is applied to rate-dependence parameters to explore its effect on the fracture patterns.

97 MATHEMATICS AND COMPUTING↗

Evaluating climate emulation: fundamental impulse testing of simple climate models

Abstract. Simple climate models (SCMs) are numerical representations of the Earth's gas cycles and climate system. SCMs are easy to use and computationally inexpensive, making them an ideal tool in both scientific and decision-making contexts (e.g., complex climate model emulation, parameter estimation experiments, climate metric calculations, and probabilistic analyses). Despite their prolific use, the fundamental responses of SCMs are often not directly characterized. In this study, we use fundamental impulse tests of three chemical species (CO2, CH4, and black carbon – BC) to understand the fundamental gas cycle and climate system responses of several comprehensive (Hector v2.0, MAGICC 5.3, MAGICC 6.0) and idealized (FAIR v1.0, AR5-IR) SCMs. We find that while idealized SCMs are widely used, they fail to capture the magnitude and timescales of global mean climate responses under emissions perturbations, which can produce biased temperature results. Comprehensive SCMs, which have physically based nonlinear forcing and carbon cycle representations, show improved responses compared to idealized SCMs. Even the comprehensive SCMs, however, fail to capture the response timescales to BC emission perturbations seen recently in two general circulation models. Some comprehensive SCMs also generally respond faster than more complex models to a 4×CO2 concentration perturbation, although this was not evident for lower perturbation levels. These results suggest where improvements should be made to SCMs. Further, we demonstrate here a set of fundamental tests that we recommend as a standard evaluation suite for any SCM. Fundamental impulse tests allow users to understand differences in model responses and the impact of model selection on results.

54 ENVIRONMENTAL SCIENCES↗

Performance Test and Evaluation on Polymer Form of Carbonized Waste - 19164

A carbonized waste is a material obtained by treating combustible wastes with superheated steam for volume reduction. A surrogate-carbonized waste was solidified to a monolith type of polymer form by using epoxy resin because it was obtained in powder form. The polymer form of carbonized waste was tested in accordance with standardized methods to evaluate its performance in terms of its mechanical integrity, durability, leaching properties, and microbiological stability for final disposal in Korea. Performance test results demonstrate that the polymer form of carbonized waste has excellent mechanical integrity and retains its structural integrity after thermal cycling, irradiation and 90-day water immersion. Leachability indices for cesium, cobalt, and strontium of the polymer form of carbonized waste were better than those required of a final disposal site in Korea. In addition, no culture growth of fungi or bacteria and no biodegradation were observed on the polymer form of carbonized waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Panels of HIV-1 Subtype C Env Reference Strains for Standardized Neutralization Assessments

In the search for effective immunologic interventions to prevent and treat HIV-1 infection, standardized reference reagents are a cost-effective way to maintain robustness and reproducibility among immunological assays. To support planned and ongoing studies where clade C predominates, here we describe three virus panels, chosen from 200 well-characterized clade C envelope (Env)-pseudotyped viruses from early infection. All 200 Envs were expressed as a single round of replication pseudoviruses and were tested to quantify neutralization titers by 16 broadly neutralizing antibodies (bnAbs) and sera from 30 subjects with chronic clade C infections. We selected large panels of 50 and 100 Envs either to characterize cross-reactive breadth for sera identified as having potent neutralization activity based on initial screening or to evaluate neutralization magnitude-breadth distributions of newly isolated antibodies. We identified these panels by downselection after hierarchical clustering of bnAb neutralization titers. The resulting panels represent the diversity of neutralization profiles throughout the range of virus sensitivities identified in the original panel of 200 viruses. A small 12-Env panel was chosen to screen sera from vaccine trials or natural-infection studies for neutralization responses. We considered panels selected by previously described methods but favored a computationally informed method that enabled selection of viruses representing diverse neutralization sensitivity patterns, given that we do not a priori know what the neutralization-response profile of vaccine sera will be relative to that of sera from infected individuals. The resulting 12-Env panel complements existing panels. Use of standardized panels enables direct comparisons of data from different trials and study sites testing HIV-1 clade C-specific products. HIV-1 group M includes nine clades and many recombinants. Clade C is the most common lineage, responsible for roughly half of current HIV-1 infections, and is a focus for vaccine design and testing. Standard reference reagents, particularly virus panels to study neutralization by antibodies, are crucial for developing cost-effective and yet rigorous and reproducible assays against diverse examples of this variable virus. We developed clade C-specific panels for use as standardized reagents to monitor complex polyclonal sera for neutralization activity and to characterize the potency and breadth of cross-reactive neutralization by monoclonal antibodies, whether engineered or isolated from infected individuals. We chose from 200 southern African, clade C envelope-pseudotyped viruses with neutralization titers against 16 broadly neutralizing antibodies and 30 sera from chronic clade C infections. We selected panels to represent the diversity of bnAb neutralization profiles and Env neutralization sensitivities. Finally, use of standard virus panels can facilitate comparison of results across studies and sites.

59 BASIC BIOLOGICAL SCIENCES↗

1000–ton testing machine for cyclic fatigue tests of materials at liquid nitrogen temperatures

One of the main tasks of superconductive magnets R and D is to determine the mechanical and fatigue properties of structural materials and the critical design elements in the cryogenic temperature range. This paper describes a new facility built based on the industrial 1000-ton (10 MN) testing machine Schenk PC10.0S. Special equipment was developed to provide the mechanical and cyclic tensile fatigue tests of large-scale samples at the liquid nitrogen temperature and in a given load range. The main feature of the developed testing machine is the cryostat, in which the device converting a standard compression force of the testing machine to the tensile force affected at the test object is placed. The control system provides the remote control of the test and obtaining, processing and presentation of test data. As an example of the testing machine operation the test program and test results of the cyclic tensile fatigue tests of fullscale helium inlet sample of the PF1 coil ITER are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Humidity effects on wire insulation breakdown strength.

Methods for the testing of the dielectric breakdown strength of insulation on metal wires under variable humidity conditions were developed. Two methods, an ASTM method and the twisted pair method, were compared to determine if the twisted pair method could be used for determination of breakdown strength under variable humidity conditions. It was concluded that, although there were small differences in outcomes between the two testing methods, the non-standard method (twisted pair) would be appropriate to use for further testing of the effects of humidity on breakdown performance. The dielectric breakdown strength of 34G copper wire insulated with double layer Poly-Thermaleze/Polyamide-imide insulation was measured using the twisted pair method under a variety of relative humidity (RH) conditions and exposure times. Humidity at 50% RH and below was not found to affect the dielectric breakdown strength. At 80% RH the dielectric breakdown strength was significantly diminished. No effect for exposure time up to 140 hours was observed at 50 or 80%RH.

Appelhans, Leah↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Shaker-structure interaction modeling and analysis for nonlinear force appropriation testing

Nonlinear force appropriation is an extension of its linear counterpart where sinusoidal excitation is applied to a structure with a modal shaker and phase quadrature is achieved between the excitation and response. While a standard practice in modal testing, modal shaker excitation has the potential to alter the dynamics of the structure under test. Previous studies have been conducted to address several concerns, but this work specifically focuses on a shaker-structure interaction phenomenon which arises during the force appropriation testing of a nonlinear structure. Under pure-tone sinusoidal forcing, a nonlinear structure may respond not only at the fundamental harmonic but also potentially at sub- or superharmonics, or it can even produce aperiodic and chaotic motion in certain cases. Shaker-structure interaction occurs when the response physically pushes back against the shaker attachment, producing non-fundamental harmonic content in the force measured by the load cell, even for pure tone voltage input to the shaker. This work develops a model to replicate these physics and investigates their influence on the response of a nonlinear normal mode of the structure. Experimental evidence is first provided that demonstrates the generation of harmonic content in the measured load cell force during a force appropriation test. This interaction is replicated by developing an electromechanical model of a modal shaker attached to a nonlinear, three-mass dynamical system. Several simulated experiments are conducted both with and without the shaker model in order to identify which effects are specifically due to the presence of the shaker. Finally, the results of these simulations are then compared to the undamped nonlinear normal modes of the structure under test to evaluate the influence of shaker-structure interaction on the identified system’s dynamics.

42 ENGINEERING↗

An Affordable Test Approach for Lunar Fission Surface Power Systems

The objective of the Fission Surface Power System (FSPS) development and qualification program is to assure that the components, subsystems and complete power system satisfy all of their mission requirements with a sufficiently high level of confidence. To accomplish this objective, the FSPS program will conduct nuclear and non-nuclear development and testing in compliance with standard NASA practice for all of the reactor, power conversion, and system integration hardware and software items. The anticipated program includes extensive performance and environmental testing of components throughout their predicted operational conditions and possible fault conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗