Search NASA⌕ Search

SEARCH · Search NASA

Results for “acquisition function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Vibration Pattern Imager (VPI): A control and data acquisition system for scanning laser vibrometers

The Vibration Pattern Imager (VPI) system was designed to control and acquire data from scanning laser vibrometer sensors. The PC computer based system uses a digital signal processing (DSP) board and an analog I/O board to control the sensor and to process the data. The VPI system was originally developed for use with the Ometron VPI Sensor, but can be readily adapted to any commercially available sensor which provides an analog output signal and requires analog inputs for control of mirror positioning. The sensor itself is not part of the VPI system. A graphical interface program, which runs on a PC under the MS-DOS operating system, functions in an interactive mode and communicates with the DSP and I/O boards in a user-friendly fashion through the aid of pop-up menus. Two types of data may be acquired with the VPI system: single point or 'full field.' In the single point mode, time series data is sampled by the A/D converter on the I/O board (at a user-defined sampling rate for a selectable number of samples) and is stored by the PC. The position of the measuring point (adjusted by mirrors in the sensor) is controlled via a mouse input. The mouse input is translated to output voltages by the D/A converter on the I/O board to control the mirror servos. In the 'full field' mode, the measurement point is moved over a user-selectable rectangular area. The time series data is sampled by the A/D converter on the I/O board (at a user-defined sampling rate for a selectable number of samples) and converted to a root-mean-square (rms) value by the DSP board. The rms 'full field' velocity distribution is then uploaded for display and storage on the PC.

Rizzi, Stephen A.↗

Isotope ratio characteristics and sensitivity for uranium determinations using a liquid sampling-atmospheric pressure glow discharge ion source coupled to an Orbitrap mass analyzer

Abstract The continued development of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma as an ion source for diverse, elemental/isotopic analysis applications continues. To this end, characterization of the capabilities in performing precise and accurate isotope ratio (IR) determinations is essential. Based on past experience with the Thermo Exactive Orbitrap mass analyzer, the LS-APGD was interfaced with this instrument for these tests. While the Orbitrap platform has demonstrated excellent mass resolution and accuracy in “organic” mass spectrometry (MS) applications, work using an Orbitrap for IR analysis is very sparse. These efforts build off previous work in this coupling, where the importance of a few of the LS-APGD discharge parameters and Orbitrap data acquisition methods on IR precision and accuracy were probed. Presented here are the results of a study that evaluated the analytical precision for natural uranium sample (assumed 235U/238U = 0.0072) determinations. The instrumental parameters evaluated include the number of microscans and scans making up a data acquisition set, uranium concentration/signal level, sample make-up, and Fourier transform digitization window. Ultimately, a precision of 0.41% relative standard deviation (RSD) can be achieved for a single determination, with a reproducibility of 1.63 %RSD over 10 separate analytical measurements. A preliminary study of matrix effects on IR measurements of U is presented, highlighting the importance of pre-mass selection before injection into the Orbitrap. The analytical system sensitivity is suggested with the ability to produce a calibration function having an R2 value of >0.99 over a range of 4 orders of magnitude of concentration (~1 – 1000 ng mL-1). These efforts demonstrate the very promising pairing of the LS-APGD ionization source and the Orbitrap, pointing as well to definitive paths forward to better utilize both components in high quality isotope ratio mass spectrometry (IRMS).

Environmental Molecular Sciences Laboratory↗

APS Data Management System

As the capabilities of modern X-ray detectors and acquisition technologies increase, so do the data rates and volumes produced at synchrotron beamlines. This brings into focus a number of challenges related to managing data at such facilities, including data transfer, near real-time data processing, automated processing pipelines, data storage, handling metadata and remote user access to data. The Advanced Photon Source Data Management System software is designed to help beamlines deal with these issues. Finally, this paper presents the system architecture and describes its components and functionality; the system's current usage is discussed, examples of its use have been provided and future development plans are outlined.

97 MATHEMATICS AND COMPUTING↗

Dynamic scan control in STEM: spiral scans

Abstract Scanning transmission electron microscopy (STEM) has emerged as one of the foremost techniques to analyze materials at atomic resolution. However, two practical difficulties inherent to STEM imaging are: radiation damage imparted by the electron beam, which can potentially damage or otherwise modify the specimen and slow-scan image acquisition, which limits the ability to capture dynamic changes at high temporal resolution. Furthermore, due in part to scan flyback corrections, typical raster scan methods result in an uneven distribution of dose across the scanned area. A method to allow extremely fast scanning with a uniform residence time would enable imaging at low electron doses, ameliorating radiation damage and at the same time permitting image acquisition at higher frame-rates while maintaining atomic resolution. The practical complication is that rastering the STEM probe at higher speeds causes significant image distortions. Non-square scan patterns provide a solution to this dilemma and can be tailored for low dose imaging conditions. Here, we develop a method for imaging with alternative scan patterns and investigate their performance at very high scan speeds. A general analysis for spiral scanning is presented here for the following spiral scan functions: Archimedean, Fermat, and constant linear velocity spirals, which were tested for STEM imaging. The quality of spiral scan STEM images is generally comparable with STEM images from conventional raster scans, and the dose uniformity can be improved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Substation Circuit Breaker SCADA Cut-Over

The electric power industry has a unique set of issues related to the infrastructure put in place since the 1880s. As methods of generation, delivery and protection evolve, so must the equipment used by the utility. Furthermore, the equipment in use has a finite life and must be replaced over time. The substation at which this project takes place was originally built in the 1950s, though most of the equipment had already gone through several updates. The issue presented was upgrading the Supervisory Control and Data Acquisition (SCADA) system for all the devices connected to the last SCADA system installed a few decades ago. Though the SCADA system being replaced was connected to substation transformers, breakers, disconnects, relays and other devices, the scope of this report will focus on the cut-over of a single gas circuit breaker. After connecting the circuit breaker to the new SCADA, a system and operability (SO) test would need to be designed and carried out to validate the proper function of the device before returning it to service. This report will follow the design approach, execution, testing, and troubleshooting for the substation circuit breaker SCADA cut-over.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Time Delay from Corona to Breakdown

This report describes measurements of the time delay between the onset of corona and complete electrical breakdown between a point and a plane in dry air near atmospheric pressure as a function of the distance between the point and the plane. The large variation in these time delays is representative of the stochastic nature of electrical breakdown and the many possible phenomena that occur between the initiation and completion of electrical breakdown, including initiation without complete electrical breakdown. The purpose of this work is to provide data which will be accurately modeled when a model contains the appropriate mechanisms with the proper priorities to describe this fundamental electrical breakdown configuration. The acquisition of these measurements completes a level three milestone for the WSEAT program which sponsors this research. Also included in this report is a description of our plans to “automate” the experimental procedure, protect the high sensitivity fast-gated camera, and add diagnostics and new experimental techniques to the test facility. This will provide measurements of the time delay distributions with improved statistics and additional experimental information about the processes that occur during electrical breakdown.

42 ENGINEERING↗

TIA Software User's Manual

This user's manual describes the installation and operation of TIA, the Thermal-Imaging acquisition and processing Application, developed by the Nondestructive Evaluation Sciences Branch at NASA Langley Research Center, Hampton, Virginia. TIA is a user friendly graphical interface application for the Macintosh 2 and higher series computers. The software has been developed to interface with the Perceptics/Westinghouse Pixelpipe(TM) and PixelStore(TM) NuBus cards and the GW Instruments MacADIOS(TM) input-output (I/O) card for the Macintosh for imaging thermal data. The software is also capable of performing generic image-processing functions.

Cramer, K. Elliott↗

A Co-Investigator Project for the Cornell University Cleft Accelerated Plasma Experimental Rocket-CAPER

The CAPER rocket campaign was to follow the SCIFER experiment as a detailed study of the ion acceleration processes in the Cleft Ion Fountain (CIF) above 1000 km altitude. The SCIFER rocket demonstrated that the experiment was feasible and that the CIF acceleration processes on the dayside are different from those observed in the discrete aurora on the nightside. The responsibility of the GI/UAF co-investigator project was to provide the real-time acquisition and display of large-and small-scale ground observations, and satellite solar wind data at the launch control center at Longyearbyen, Svalbard for the determination of the launch conditions and the later interpretation of the rocket observations. The rocket campaign was proposed for January of 1998, but was slipped to January of 1999. The rocket was launched on January 21, 1999 at 06 h 13 m 30 s UT. All of the GI/UAF co-investigator systems functioned well, except the narrow-field TV camera which was to follow the 140 km conjugate of the payload on command from GPS tracking data sent from Andoya. The data were not available during the flight, and the camera tracked the nominal conjugate. Unfortunately, the trajectory was well west of nominal, so no useful narrow-field conjugate data were acquired . In addition, the payload missed the region of more intense precipitation, brighter aurora, stronger currents, and likely large fluxes of transverse ion acceleration. On the other hand, good data were acquired across a region of the ionosphere that appears to have had a double convection boundary because of the IMF switching its z component shortly before launch. These data are important for understanding the reaction of the magnetosphere and ionosphere to changes in the IMF.

Deehr, Charles S.↗

In-Situ phase and texture characterization of solution deposited PZT thin films during crystallization.

Ferroelectric lead zirconate titanate (PZT) thin films are used for integrated capacitors, ferroelectric memory, and piezoelectric actuators. Solution deposition is routinely used to fabricate these thin films. During the solution deposition process, the precursor solutions are spin coated onto the substrate and then pyrolyzed to form an amorphous film. The amorphous film is then heated at a higher temperature (650-700 C) to crystallize the film into the desired perovskite phase. Phase purity is critical in achieving high ferroelectric properties. Moreover, due to the anisotropy in the structure and properties of PZT, it is desirable to control the texture obtained in these thin films. The heating rate during crystallization process is known to affect the sequence of phase evolution and texture obtained in these thin films. However, to date, a comprehensive understanding of how phase and texture evolution takes place is still lacking. To understand the effects of heating rate on phase and texture evolution, in-situ diffraction experiments during the crystallization of solution deposited PZT thin films were carried out at beamline 6-ID-B, Advanced Photon Source (APS). The high X-ray flux coupled with the sophisticated detectors available at the APS synchrotron source allow for in-situ characterization of phase and texture evolution at the high ramp rates that are commonly used during processing of PZT thin films. A PZT solution of nominal composition 52/48 (Zr/Ti) was spin coated onto a platinum-coated Si substrate (Pt//TiO{sub x}//SiO{sub 2}//Si). The films were crystallized using an infrared lamp, similar to a rapid thermal annealing furnace. The ramp rate was adjusted by controlling the voltage applied to the infrared lamp and increasing the voltage by a constant step with every acquisition. Four different ramp rates, ranging from {approx}1000 C/s to {approx}1 C/s, were investigated. The sample was aligned in grazing incidence to maximize the signal from the thin films. Successive diffraction patterns were acquired with a 1s acquisition time using a MAR SX-165 CCD detector during crystallization. The sample to detector distance and the tilt rotations of the detector were determined in Fit2D{copyright} by using Al{sub 2}O{sub 3} as the calibrant. These corrections were applied to the patterns when binning the data into radial (2{theta}) and azimuthal bins. The texture observed in the thin film was qualitatively analyzed by fitting the intensity peaks along the azimuthal direction with a gaussian profile function to obtain the integrated intensity of the peaks. Data analysis and peak fitting was done using the curve fitting toolbox in MATLAB{copyright}. A fluorite-type phase was observed to form before the perovskite phase for all ramp rates. PtxPb is a transient intermetallic formed due to the interaction of the thin film and the bottom electrode during crystallization. Ramp rate was observed to significantly affect the amount of PtxPb observed in the thin films during crystallization. Ramp rate was also observed to affect the final texture obtained in the thin films. These results will be discussed in the poster in view of the current understanding of these materials.

43 PARTICLE ACCELERATORS↗

Domain-specific functional software testing: A progress report

Software Engineering is a knowledge intensive activity that involves defining, designing, developing, and maintaining software systems. In order to build effective systems to support Software Engineering activities, Artificial Intelligence techniques are needed. The application of Artificial Intelligence technology to Software Engineering is called Knowledge-based Software Engineering (KBSE). The goal of KBSE is to change the software life cycle such that software maintenance and evolution occur by modifying the specifications and then rederiving the implementation rather than by directly modifying the implementation. The use of domain knowledge in developing KBSE systems is crucial. Our work is mainly related to one area of KBSE that is called automatic specification acquisition. One example is the WATSON prototype on which our current work is based. WATSON is an automatic programming system for formalizing specifications for telephone switching software mainly restricted to POTS, i.e., plain old telephone service. Our current approach differentiates itself from other approaches in two antagonistic ways. On the one hand, we address a large and complex real-world problem instead of a 'toy domain' as in many research prototypes. On the other hand, to allow such scaling, we had to relax the ambitious goal of complete automatic programming, to the easier task of automatic testing.

Nonnenmann, Uwe↗

Mycorrhiza helper bacteria

This chapter focuses on the Mycorrhiza Helper Bacteria (MHB), a generic name given to bacteria which stimulate the formation of mycorrhizal symbiosis. By extension, some bacterial strains that positively impact the functioning of mycorrhizal symbiosis are also called MHB. These bacteria have applicative interests, as they indirectly improve the health and growth of tree seedlings. MHB are not restricted to a specific type of ecosystem, but are rather generalist in the way that they associate with both herbaceous and woody mycorrhizal plants from boreal, temperate, arid and tropical ecosystems. However, understanding the molecular mechanisms and their specificities will help us to know more about the ecology of the MHB. The process of acquisition varies between fungal species; while ectomycorrhizal fungi most probably recurrently acquire them from the environment, the association between bacterial endosymbionts and Glomeromycota probably dates back to very ancient times, and has since been vertically transmitted.

Deveau, Aurelie↗

A gimbal platform stabilization for topographic applications

The aim of this work is the stabilization of a Gimbal platform for optical sensors acquisitions in topographic applications using mobile vehicles. The stabilization of the line of sight (LOS) consists in tracking the command velocity in presence of nonlinear noise due to the external environment. The hardware architecture is characterized by an Ardupilot platform that allows the control of both the mobile device and the Gimbal. Here we developed a new approach to stabilize the Gimbal platform, which is based on neural network. For the control system, we considered a plant that represents the transfer function of the servo system control model for an inertial stabilized Gimbal platform. The transductor used in the feed-back line control is characterized by the Rate Gyro transfer function installed onboard of Ardupilot. For the simulation and investigation of the system performance, we used the Simulink tool of Matlab. Results show that the hardware/software approach is efficient, reliable and cheap for direct photogrammetry, as well as for general purpose applications using mobile vehicles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TH-C-17A-05: Cherenkov Excited Phosphorescence Oxygen (CEPhOx) Imaging During Multi-Beam Radiation Therapy

Purpose: Cherenkov radiation is created during external beam radiation therapy that can excite phosphorescence in tissue from oxygen-sensitive, bio-compatible probes. Utilizing the known spatial information of the treatment plan with directed multiple beam angles, Cherenkov Excited Phosphorescence Oxygen (CEPhOx) imaging was realized from the reconstructions of Cherenkov excited phosphorescence lifetime. Methods: Platinum(II)-G4 (PtG4) was used as the oxygen-sensitive phosphorescent probe and added to a oxygenated cylindrical liquid phantom with a oxygenated/deoxygenated cylindrical anomaly. Cherenkov excited phosphorescence was imaged using a time-gated ICCD camera temporallysynchronized to the LINAC pulse output. Lifetime reconstruction was carried out in NIRFAST software. Multiple angles of the incident radiation beam was combined with the location of the prescribed treatment volume (PTV) to improve the tomographic recovery as a function of location. The tissue partial pressure of oxygen (pO2) in the background and PTV was calculated based on the recovered lifetime distribution and Stern-Volmer equation. Additionally a simulation study was performed to examine the accuracy of this technique in the setting of a human brain tumor. Results: Region-based pO2 values in the oxygenated background and oxygenated/deoxygenated PTV were correctly recovered, with the deoxygenated anomaly (15.4 mmHg) easily distinguished from the oxygenated background (143 mmHg). The data acquisition time could be achieved within the normal irradiation time for a human fractionated plan. The simulations indicated that CEPhOx would be a sufficient to sample tumor pO2 sensing from tumors which are larger than 2cm in diameter or within 23mm depth from the surface. Conclusion: CEPhOx could be a novel imaging tool for pO2 assessment during external radiation beam therapy. It is minimally invasive and should work within the established treatment plan of radiation therapy with multiple beams in situations where tumor pO2 measurement is a pertinent radiotherapy efficiency and dosimetric need.

07 ISOTOPE AND RADIATION SOURCES↗

Poster — Thur Eve — 44: Linearization of Compartmental Models for More Robust Estimates of Regional Hemodynamic, Metabolic and Functional Parameters using DCE-CT/PET Imaging

Quantitative analysis of dynamic positron emission tomography (PET) data usually involves minimizing a cost function with nonlinear regression, wherein the choice of starting parameter values and the presence of local minima affect the bias and variability of the estimated kinetic parameters. These nonlinear methods can also require lengthy computation time, making them unsuitable for use in clinical settings. Kinetic modeling of PET aims to estimate the rate parameter k{sub 3}, which is the binding affinity of the tracer to a biological process of interest and is highly susceptible to noise inherent in PET image acquisition. We have developed linearized kinetic models for kinetic analysis of dynamic contrast enhanced computed tomography (DCE-CT)/PET imaging, including a 2-compartment model for DCE-CT and a 3-compartment model for PET. Use of kinetic parameters estimated from DCE-CT can stabilize the kinetic analysis of dynamic PET data, allowing for more robust estimation of k{sub 3}. Furthermore, these linearized models are solved with a non-negative least squares algorithm and together they provide other advantages including: 1) only one possible solution and they do not require a choice of starting parameter values, 2) parameter estimates are comparable in accuracy to those from nonlinear models, 3) significantly reduced computational time. Our simulated data show that when blood volume and permeability are estimated with DCE-CT, the bias of k{sub 3} estimation with our linearized model is 1.97 ± 38.5% for 1,000 runs with a signal-to-noise ratio of 10. In summary, we have developed a computationally efficient technique for accurate estimation of k{sub 3} from noisy dynamic PET data.

60 APPLIED LIFE SCIENCES↗

Glomerular filtrate proteins in acute cardiorenal syndrome

Acute cardiorenal syndrome (CRS-1) is a morbid complication of acute cardiovascular disease. Heart-to-kidney signals transmitted by “cardiorenal connectors” have been postulated, but investigation into CRS-1 has been limited by technical limitations and a paucity of models. To address these limitations, we developed a translational model of CRS-1, cardiac arrest and cardiopulmonary resuscitation (CA/CPR), and now report findings from nanoscale mass spectrometry proteomic exploration of glomerular filtrate 2 hours after CA/CPR or sham procedure. Filtrate acquisition was confirmed by imaging, molecular weight and charge distribution, and exclusion of protein specific to surrounding cells. Filtration of proteins specific to the heart was detected following CA/CPR and confirmed with mass spectrometry performed using urine collections from mice with deficient tubular endocytosis. Cardiac LIM protein was a CA/CPR-specific filtrate component. Cardiac arrest induced plasma release of cardiac LIM protein in mice and critically ill human cardiac arrest survivors, and administration of recombinant cardiac LIM protein to mice altered renal function. These findings demonstrate that glomerular filtrate is accessible to nanoscale proteomics and elucidate the population of proteins filtered 2 hours after CA/CPR. The identification of cardiac-specific proteins in renal filtrate suggests a novel signaling mechanism in CRS-1. We expect these findings to advance understanding of CRS-1.

Wakasaki, Rumie (ORCID:0000000202291919)↗

NASA ground communications

As part of the Communications Requirements and Constraints, NASA's two major Ground Data Networks were briefly described. The NASA Communication Network, called NASCOM, is the worldwide operational telecommunications system which interconnects as the tracking and telemetry acquisition sites, launch areas, mission and project control centers, data capture facilities, and network control centers in support of space flight. For the Space Station era, NASCOM plans are set for higher data rate service utilizing data packet switched technology. Increased use of fiber optics is expected in a much more diverse network topology. The second major ground network, the Program Support Communications Network (PSCN), interconnects all NASA Centers and NASA contractor locations for intercenter non-operation communications. The primary functions are to transport voice, video, data and facsimile information for intercenter coordination, and to provide user access to space science and applications data bases. For the Space Station era, PSCN plans address the significant increase in forecast requirements for science data distribution and access to the Numerical Aerodynamics Simulator, and increased use of the Video Teleconference System.

Roeder, John↗

NASA Johnson Space Center Life Sciences Data System

The Life Sciences Project Division (LSPD) at JSC, which manages human life sciences flight experiments for the NASA Life Sciences Division, augmented its Life Sciences Data System (LSDS) in support of the Spacelab Life Sciences-2 (SLS-2) mission, October 1993. The LSDS is a portable ground system supporting Shuttle, Spacelab, and Mir based life sciences experiments. The LSDS supports acquisition, processing, display, and storage of real-time experiment telemetry in a workstation environment. The system may acquire digital or analog data, storing the data in experiment packet format. Data packets from any acquisition source are archived and meta-parameters are derived through the application of mathematical and logical operators. Parameters may be displayed in text and/or graphical form, or output to analog devices. Experiment data packets may be retransmitted through the network interface and database applications may be developed to support virtually any data packet format. The user interface provides menu- and icon-driven program control and the LSDS system can be integrated with other workstations to perform a variety of functions. The generic capabilities, adaptability, and ease of use make the LSDS a cost-effective solution to many experiment data processing requirements. The same system is used for experiment systems functional and integration tests, flight crew training sessions and mission simulations. In addition, the system has provided the infrastructure for the development of the JSC Life Sciences Data Archive System scheduled for completion in December 1994.

Rahman, Hasan↗

Characterization of Unimorph-Membrane Microactuators and Error-Analysis of the Characterization Process

Microactuators are versatile, low-cost, low-mass electrical-mechanical devices that can be used in many applications. Microactuators consist of two electrodes sandwiching a PZT (piezo-electric) film between them. The centers of the microactuators deflect when a voltage is applied across the electrodes. In order to correctly apply this technology for use, it is important to fully characterize the actuation behavior. Measuring the deflection profile as a function of the voltage of various microactuators is crucial. This measurement process has errors associated with it, so it is being studied to determine the accuracy of the data. In certain applications, microactuators may undergo many cycles of deflection; testing various microactuators through many cycles of deflection simulates these circumstances. However, due to an unknown issue, many of the microactuators exhibit defects that cause them to fail when voltage is applied to their electrodes. These defects do not allow for the acquisition of significant deflection profiles. Vibrations are the largest cause of error in deflection measurements, and the microactuators withstand continuous cycles of deflection, yet the cause of damage is still to be determined. Future projects will be needed to characterize the deflection profiles of various microactuators and to overcome the defects in the microactuators that are currently present.

Wright, Matthew W.↗