Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Radiometric calibration of the airborne imaging spectrometer

Several laboratory calibration tests were developed for the Airborne Imaging Spectrometer (AIS). The goals of these tests are to adjust the physical alignment of the detector within the optical system and set the spectral endpoints, and produce a calibration file of multipliers which equalizes the relative responses of each of the detector elements in the entire two-dimensional array. Tests are also performed as part of an ongoing effort to provide absolute radiometric calibration. The tests are described and the merits and limitations of each are discussed.

Tucker, D.↗

Far-Infrared Imaging Radiometer

Inexpensive far-infrared imaging radiometer contains 128 X 128-picture-element array of AlxGa1-xAs quantum-well detectors. Potentially useful in remote sensing from airborne platforms. Industrial applications include rapid thermal imaging of heat-sensitive components. Astronomical applications include imaging of planets and Sun.

Forrest, Kathrine↗

HILT - A heavy ion large area proportional counter telescope for solar and anomalous cosmic rays

The HILT sensor has been designed to measure heavy ion elemental abundances, energy spectra, and direction of incidence in the mass range from He to Fe and in the energy range 4 to 250 MeV/nucleon. With its large geometric factor of 60 sq cm sr the sensor is optimized to provide compositional and spectral measurements for low intensity cosmic rays (i.e. for small solar energetic particle events and for the anomalous component of cosmic rays). The instrument combines a large area ion drift chamber-proportional counter system with two arrays of 16 Li-drift solid state detectors and 16 CsI crystals. The multi dE/dx-E technique provides a low background mass and energy determination. The sensor also measures particle direction. Combining these measurements with the information on the spacecraft position and attitude in the low-altitude polar orbit, it will be possible to infer the ionic charge of the ions from the local cutoff of the Earth's magnetic field. The ionic charge in this energy range is of particular interest because it provides unique clues to the origin of these particles and has not been investigated systematically so far. Together with the other instruments on board SAMPEX (LEICA, MAST, and PET), a comprehensive measurement of the entire solar and anomalous particle population will be achieved.

Klecker, Berndt↗

BIB mixers

We have determined that the multi-pin 'microprocessor style' packages in which current Blocked Impurity Band (BIB) devices are mounted will not meet our IF bandwidth spec of greater than 2 GHz for a practical mixer. Hence we have started to repackage the Ga:Ge BIB devices in new microwave compatible packages. The smaller size of the microwave package mount necessitates cutting the BIB array down to include only the 3 smallest detectors: 0.2, 0.4, and 0.6 mm sq. A FIR beam incident at f/1.5 can be focussed on the smallest element for wavelengths shorter than 100 microns. A more typical (easier) beam convergence of f/3 will require 0.4 mm elements at 100 microns and 0.6 mm elements at 170 microns wavelength. Since the device capacitance (parasitic loss) scales with detector size, there is a tradeoff of speed of response and optical convenience. Our existing optics produce only the slower convergence beam, so we need to redesign the optical layout and are looking at long focal length all-reflective microscope objectives. BIB detectors and the edge-coupled microbolometers have restricted IF bandwidths, an order of magnitude less than what is possible with the Schottky-diode mixers we currently use for astronomical observations. Consequently the frequencies of the FIR laser lines must be close to the astronomical line of interest to be an effective Local Oscillator (LO). We have therefore begun a coordinated effort to discover and measure new FIR laser transition lines in close frequency coincidence with important astrophysical lines. Most of this effort involves pumping isotopic variants of known good laser molecules with laser lines from isotopic variants of CO2. We have been most successful in detecting new FIR lines in deuterated ammonia. One line in particular is very close to the frequency of HD rotational line at 2675 GHz.

Source record↗

The future of large format HgCdTe arrays for astronomy

Rockwell has developed the 256 x 256 Near Infrared Camera and Multi-Object Spectrometer 3 (NICMOS3) FPA for the Hubble Space Telescope under funding from NASA through the University of Arizona. Since 1989, dozens of science grade devices have been delivered to astronomers throughout the world for ground based infrared observations. These devices have excellent sensitivity at 77 K with mean dark currents of 0.1 e(-)/s, noise of 25 e(-), and quantum efficiency of 55-70%. Pixel yields as high as 99.9% have been achieved. Our present plans are to develop a 1024 x 1024 focal plane array (FPA) with 2.5 micron cutoff and make it available to astronomers. Such large arrays are made possible by the advances in detector material size (3 in. diameter producible alternative to CdTe for epitaxy (PACE-I) wafers), multiplexer advances (ability to verify the design in detail and availability of advanced foundries), and novel hybridization and reliability approaches.

Vural, K.↗

Performance of the SBRC 190, a cryogenic multiplexer for photoconductor arrays

The SBRC 190 cryogenic readouts were developed for use with far-infrared arrays of Ge:Sb and Ge:Ga photoconductor detectors. The SBRC 190 provides an AC-coupled CTIA (capacitance transimpedance amplifier) unit cell for each detector and multiplexes up to 32 detectors. This paper presents our test results characterizing and optimizing the performance of these novel devices. We will discuss their basic behavior in addition to describing the trade-offs inherent in different sampling strategies.

Dotson, Jessie L.↗

Development of High Resolution Mirrors and Cd-Zn-Te Detectors for Hard X-ray Astronomy

We describe the fabrication and implementation of a high-resolution conical, grazing- incidence, hard X-ray (20-70 keV) telescope. When flown aboard stratospheric balloons, these mirrors are used to image cosmic sources such as supernovae, neutron stars, and quasars. The fabrication process involves generating super-polished mandrels, mirror shell electroforming, and mirror testing. The cylindrical mandrels consist of two conical segments; each segment is approximately 305 mm long. These mandrels are first, precision ground to within approx. 1.0 micron straightness along each conical segment and then lapped and polished to less than 0.5 micron straightness. Each mandrel segment is the super-polished to an average surface roughness of approx. 3.25 angstrom rms. By mirror shell replication, this combination of good figure and low surface roughness has enabled us to achieve 15 arcsec, confirmed by X-ray measurements in the Marshall Space Flight Center 102 meter test facility. To image the focused X-rays requires a focal plane detector with appropriate spatial resolution. For 15 arcsec optics of 6 meter focal length, this resolution must be around 200 microns. In addition, the detector must have a high efficiency, relatively high energy resolution, and low background. We are currently developing Cadmium-Zinc-Telluride fine-pixel detectors for this purpose. The detectors under study consist of a 16x16 pixel array with a pixel pitch of 300 microns and are 1 mm and 2 mm thick. At 60 keV, the measured energy resolution is around 2%.

Ramsey, Brian D.↗

The X-ray Microcalorimeter Spectrometer (XMS): A Reference Cryogenic Instrument Design for Constellation-X

Constellation-X, a mission now belonging to the Beyond Einstein initiative, is being planned to inherit the x-ray sky from Chandra, XMM-Newton and Astro-E. The first two of four observatories in the constellation will be launched together in 2013 and followed a year later by the launch of the remaining two. The four will independently orbit the Sun-Earth Lagrange point L2. An instrument compliment resides in the Focal Plane Module (FPM) of each observatory 10 m from the Optics Module and consists of three Hard X-ray Telescope (HXT) detectors, a Reflection Grating Spectrometer (RGS) focal plane CCD camera and an X-ray Microcalorimeter Spectrometer (XMS). Instrument awards are scheduled for early 2006. The reference detector for XMS is a 32 x 32 array of microcalorimetric superconducting Transition Edge Sensors (TES). Each pixel casts a variable resistance in a SQUID based multiplexed readout circuit which is coupled to series SQUID arrays for amplification and finally read out by external electronics. A multi-stage continuous ADR will provide the stable 50 mK desired for the TES array and a stable 1 K for the series SQUID arrays while also lifting thermal parasitic and inefficiency loads to a 6 K cryocooler interface. The 6 K cryocooler is expected to emerge from the joint-project Advanced Cryocooler Technology Development Program (ACTDP) in which Constellation-X is an active participant. Project Pre-Formulation activities are marked by extensive technology development necessitating early, but realistic, thermal and cooling load requirements for ADR and ACTDP-cryocooler design points. Such requirements are driven by the encompassing XMS cryostat and ultimately by the thermal environment imposed by the FPM. It is further desired that the XMS instrument be able to operate on its side in the laboratory, with a warm vacuum shell, during an extensive calibration regime. It is that reference system design of the XMS instrument (microcalorimeter, ADR, cryocooler and cryostat) which is the subject of this paper.

Whitehouse, Paul L.↗

Building the James Webb Space Telescope

The James Webb Space Telescope is the scientific successor to the Hubble and Spitzer Space Telescopes. It will be a large (6.6m) cold (50K) telescope launched into orbit around the second Earth-Sun Lagrange point. It is a partnership of NASA with the European and Canadian Space Agencies. JWST will make progress In almost every area of astronomy, from the first galaxies to form in the early universe to exoplanets and Solar System objects. Webb will have four instruments: The Near-Infrared Camera, the Near-Infrared multi-object Spectrograph, and the Near-Infrared Imager and Slitless Spectrograph will cover the wavelength range 0.6 to 5 microns, while the Mid-Infrared Instrument will do both imaging and spectroscopy from 5 to 28.5 microns. The observatory Is confirmed for launch in 2018; the design is complete and it is in its construction phase. Innovations that make JWST possible include large-area low-noise infrared detectors, cryogenic ASICs, a MEMS micro-shutter array providing multi-object spectroscopy, a non-redundant mask for interferometric coronagraphy and diffraction-limited segmented beryllium mirrors with active wavefront sensing and control. Recent progress includes the completion of the mirrors, the delivery of the first flight instruments and the start of the integration and test phase.

Gardner, Jonathan P.↗

Operation of an ADR Using Helium Exchange Gas as a Substitute for a Failed Heat Switch

The Soft X-ray Spectrometer (SXS) is one of four instruments on the Japanese Astro-H mission, which is currently planned for launch in late 2015. The SXS will perform imaging spectroscopy in the soft X-ray band (0.3-12 keV) using a 6 6 pixel array of microcalorimeters cooled to 50 mK. The detectors are cooled by a 3-stage adiabatic demagnetization refrigerator (ADR) that rejects heat to either a superfluid helium tank (at 1.2 K) or to a 4.5 K Joule-Thomson (JT) cryocooler. Four gas-gap heat switches are used in the assembly to manage heat flow between the ADR stages and the heat sinks. The engineering model (EM) ADR was assembled and performance tested at NASA/GSFC in November 2011, and subsequently installed in the EM dewar at Sumitomo Heavy Industries, Japan. During the first cooldown in July 2012, a failure of the heat switch that linked the two colder stages of the ADR to the helium tank was observed. Operation of the ADR requires some mechanism for thermally linking the salt pills to the heat sink, and then thermally isolating them. With the failed heat switch unable to perform this function, an alternate plan was devised which used carefully controlled amounts of exchange gas in the dewar's guard vacuum to facilitate heat exchange. The process was successfully demonstrated in November 2012, allowing the ADR to cool the detectors to 50 mK for hold times in excess of 10 h. This paper describes the exchange-gas-assisted recycling process, and the strategies used to avoid helium contamination of the detectors at low temperature.

Adiabatic demagnetization↗

Characterization of a Photon Counting Test Bed for Space to Ground Optical Pulse Position Modulation Communications Links

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has developed a laboratory transmitter and receiver prototype of a space to ground optical communications link. The system is meant to emulate future deep space optical communication links, such as the first crewed flight of Orion, in which the transmitted laser is modulated using pulse position modulation and the receiver is capable of detecting single photons. The transmitter prototype consists of a software defined radio, a high extinction ratio electro-optic modulator system, and 1550 nm laser. The receiver is a scalable concept and utilizes a single-pixel array of fiber coupled superconducting nanowire single photon detectors. The transmit and receive waveforms follow the Consultative Committee for Space Data Systems (CCSDS) Optical Communications High Photon Efficiency Standard. This paper describes the transmitter and receiver prototypes as well as the system test configuration. System level tests results are presented and compared to predictions from software simulations.

Nappier, Jennifer M.↗

Characterization of a Photon Counting Test Bed for Space to Ground Optical Pulse Position Modulation Communications Links

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has developed a laboratory transmitter and receiver prototype of a space-to-ground optical communications link. The system is meant to emulate future deep space optical communication links, such as the first crewed flight of Orion, in which the transmitted laser is modulated using pulse position modulation and the receiver is capable of detecting single photons. The transmitter prototype consists of a software defined radio, a high extinction ratio electro-optic modulator system, and a 1550 nm laser. The receiver is a scalable concept and utilizes a single-pixel array of fiber coupled superconducting nanowire single photon detectors. The transmit and receive waveforms follow the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization Standard. A software model of the optical transmitter and receiver has also been implemented to predict performance of the optical test bed. This paper describes the transmitter and receiver prototypes as well as the system test configuration. System level tests results are presented and shown to align with predictions from software simulations. The validated software model can be used to in the future to reduce the design cycle of optical communications systems.

software defined radio↗

LaserCom System Architecture With Reduced Complexity

Spatial acquisition and precision beam pointing functions are critical to spaceborne laser communication systems. In the present invention a single high bandwidth CCD detector is used to perform both spatial acquisition and tracking functions. Compared to previous lasercom hardware design, the array tracking concept offers reduced system complexity by reducing the number of optical elements in the design. Specifically, the design requires only one detector and one beam steering mechanism. It also provides means to optically close the point-ahead control loop. The technology required for high bandwidth array tracking was examined and shown to be consistent with current state of the art. The single detector design can lead to a significantly reduced system complexity and a lower system cost.

Lesh, James R.↗

Lasercom system architecture with reduced complexity

Spatial acquisition and precision beam pointing functions are critical to spaceborne laser communication systems. In the present invention, a single high bandwidth CCD detector is used to perform both spatial acquisition and tracking functions. Compared to previous lasercom hardware design, the array tracking concept offers reduced system complexity by reducing the number of optical elements in the design. Specifically, the design requires only one detector and one beam steering mechanism. It also provides the means to optically close the point-ahead control loop. The technology required for high bandwidth array tracking was examined and shown to be consistent with current state of the art. The single detector design can lead to a significantly reduced system complexity and a lower system cost.

Lesh, James R.↗

CZT Imaging Arrays for Space Applications

The compound CZT offers great promise for space applications with applications in such areas as radiation monitoring, planetary investigations and astrophysics. As crystal quality improves, the challenge for imaging array development is to derive electrode geometries and readout electronics to satisfy particular applications and to understand how the material will perform in the space environment. An overview of present and future detector requirements will be given together with the status of current array developments.

Ramsey, Brian D.↗

Airborne imaging spectrometer - A new tool for remote sensing

The first of a new class of remote sensing instruments is described. The Airborne Imaging Spectrometer represents the first use of two-dimensional integrated infrared area arrays in a scientific application. The instrument images 32 cross-track pixels simultaneously, each in 128 spectral bands in the 1.2- to 2.4-micron region. The IFOV of the instrument is 1.9 mrad/pixel and the spectral sampling interval is 9.6 nm. Plans include upgrading the detector from the current 32 x 32 element HgCdTe CCD array to a 64 x 64 element array in 1985. Science and engineering data are currently being actively gathered with the instrument.

Vane, G.↗

Airborne imaging spectrometer - A new tool for remote sensing

The first of a new class of remote sensing instruments is described. The Airborne Imaging Spectrometer represents the first use of two-dimensional area arrays in a scientific application. The instrument images 32 cross-track pixels simultaneously, each in 128 spectral bands in the 1.2 to 2.4 micro region. The IFOV of the instrument is 1.9 mrad and the spectral sampling interval is 9.6 nanometers. Plans include upgrading the detector from the current 32 x 32 element HgCdTe CCD array to a 64 x 64 element array in 1984. Science and engineering data are currently being actively gathered with the instrument.

Vane, G.↗

Superconducting Sensors for Microwave and Optical Photon-Starved Communications (Plenary)

NASA mission modeling indicates a desire for approximately a tenfold data improvement per decade from the Deep Space Network through the year 2040. Some of this improvement will come from aperture enhancement and antenna arraying, increased use of Ka-band over X-band, and high performance optical terminals (e.g. 12 m ground telescope). The remainder will depend on "disruptive" technologies. Deep-space communications differs from near earth communications. One way light travel times are measured in minutes rather than seconds and distances involved are large enough such that optical signals are photon limited and microwave signals have extremely low flux density. High frequency SQIF receivers and single photon detectors for optical communications will be described. Specifically, progress towards a "noiseless" receiver based on arrays of incommensurate area SQUIDs, and single photon counting detectors based on superconducting nanowires and kinetic inductance effects, will be discussed. Finally, the design of an optimal array of optical telescopes to emulate performance of a monolithic 12 m telescope will be outlined. In this case, optimal means minimizing the initial capital investment and operational cost while maintaining performance requirements of the deep-space link.

Romanofsky, Bob↗