Search NASA⌕ Search

SEARCH · Search NASA

Results for “arraying”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Structural, Optical, and Magnetic Properties of Hydrothermally Grown Fe-Doped ZnO Nanorod Arrays on Glass Substrate

In this paper, undoped and Fe-doped ZnO nanorod arrays were grown on glass substrate by a facile hydrothermal method. Structural, optical, and magnetic properties of the prepared nanorods were investigated. Structural investigation clearly showed that the prepared nanorods had single phase wurtzite structure without any secondary phases and the prepared undoped and Fe-doped nanorods were grown vertically. The optical characterization revealed that the optical band gap of ZnO nanorods was decreased by increasing the value of Fe concentration. Furthermore, the formation of diluted magnetic semiconductor nanorod arrays was verified. The origin of room temperature ferromagnetism is explained by the bound magnetic polaron concept.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Design of a wideband microstrip nanoantenna array

This paper presents the design of a logarithmic array of microstrip nano-antennas at terahertz frequencies. For applications in which small antennas are required, microstrip antennas are preferred. However, they have a narrow bandwidth. To overcome this problem in microstrip antennas, a log-periodic nanoantenna design is presented which exhibits a wide bandwidth and ultra-compact design. This antenna is smaller in size compared to log-periodic antennas in microwave bands and comparable and better radiation characteristics. The proposed Log-periodic microstrip nanoantenna array consists of seven patch elements on a dielectric layer and are fed directly by a feed line through the branch lines connected to each of the elements. Scaling factor, τ = 0.95 is considered for this design and inset feed is used. In this structure, the substrate has a relative dielectric constant of ε{sub r} = 4.4 and a thickness of h = 800 nm. For good performance at high frequencies, gold is used for the design of the antenna. The considered operating frequency is 3.3 THz corresponding to a wavelength of 91 µm. Good impedance matching and a wide bandwidth of 800 GHz is obtained.

42 ENGINEERING↗

Topological plasmonic modes in graphene-coated nanowire arrays

We investigate the topological edge modes of surface plasmonic polaritons (SPPs) in a two-dimensional waveguide array composed of graphene-coated nanowires. The system experiences topological phase transition by tuning the inter-layer spacing between adjacent unit cells. The topological modes emerge at the edge of topological non-trivial nanowire arrays when the intra-layer spacing is larger than the inter-layer spacing. Thanks to the strong confinement of graphene SPPs, the modal wavelength of topological edge modes can be squeezed as small as 1/20 of incident wavelength. The study provides a promising approach to realizing robust light transport beyond diffraction limit.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Numerical analysis of temperature and stress fields in hybrid indium antimonide arrays detector with laser irradiation

Thermal-stress effects are the major cause of failure in infrared focal-plane arrays detector, during laser irradiation. Based on the established three-dimensional structural model of hybrid indium antimonide infrared focal-plane arrays, the temperature and stress fields of hybrid indium antimonide detectors irradiated by 1.064-μm Gauss pulsed laser are studied, considering the temperature-dependent material parameters. The results indicate that the temperature increase and thermal stress effects are different, in each layer. Especially in indium antimonide chip, which is the uppermost layer of the indium antimonide detector that directly absorbs laser energy, the temperature shows not a smooth decrease as laser intensity from centre to outside, but a concentric-ringed ripple decrease with discontinuous high temperature extremum areas; which induces its own unique stress distributions: during the laser irradiation region, the thermal stress in areas above indium bumps is much lower than that in areas above underfill, but the stress distribution outside the laser irradiation region is exactly the opposite. The temperature and stress distribution in other materials are also different from that in indium antimonide chip. The main reason is that each material has different thermal properties, especially indium bump and underfill, which are alternative distribution in middle layers, have quite different thermal parameters. All these make the temperature and stress distribution in each layer having own characteristics. In addition, the change trend of the maximum temperature and stress in each layer in accordance with the laser pulse number are also studied. The maximum stress as well as temperature always occurs in the indium antimonide chip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydrodynamic characterization of the coastal pioneer array ocean observing system

Ocean observation buoys require relatively small amounts of power, yet traditionally necessitate costly resupply trips for battery replacement. With the offshore location of the buoys and small power requirements, wave energy may be an effective solution for providing consistent and reliable power to support the buoy instrumentation. The US National Science Foundation Ocean Observatories Initiative (OOI) includes arrays of point absorber-like buoy systems used for ocean observation that have been deployed at multiple locations including the Southern Mid-Atlantic Bight. A study is currently underway to design a pitch resonator wave energy converter to supplement existing renewable energy generation for powering observation instrumentation. This paper details field measurements from surface moorings of the OOI Coastal Pioneer Array, which informs the subsequent development of a numerical model for the moored observation system. The model is developed in Wave Energy Converter Simulator (WEC-Sim), which leverages the Simscape multibody solver within the MATLAB/Simulink framework and linear potential flow theory to simulate the hydrodynamic interactions and multibody dynamics in 6 degrees of freedom. Multiple tuning variables are considered to produce a model for the system that matches well with empirical data (about 8% error). In conclusion, the WEC-Sim model will serve as a platform for integrating the pitch resonator wave energy converter concept and deployment preparation (detailed design including power take-off and control systems, response evaluation, etc.).

hydrodynamic modeling↗

A new method for multi-bit and qudit transfer based on commensurate waveguide arrays

The faithful state transfer is an important requirement in the construction of classical and quantum computers. While the high-speed transfer is realized by optical-fibre interconnects, its implementation in integrated optical circuits is affected by cross-talk. The cross-talk between densely packed optical waveguides limits the transfer fidelity and distorts the signal in each channel, thus severely impeding the parallel transfer of states such as classical registers, multiple qubits and qudits. Here, we leverage on the suitably engineered cross-talk between waveguides to achieve the parallel transfer on optical chip. Waveguide coupling coefficients are designed to yield commensurate eigenvalues of the array and hence, periodic revivals of the input state. While, in general, polynomially complex, the inverse eigenvalue problem permits analytic solutions for small number of waveguides. We present exact solutions for arrays of up to nine waveguides and use them to design realistic buses for multi-(qu)bit and qudit transfer. Advantages and limitations of the proposed solution are discussed in the context of available fabrication techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low Temperature Propane Oxidation over Co 3 O 4 based Nano-array Catalysts. Ni Dopant Effect, Reaction Mechanism and Structural Stability

Low temperature propane oxidation has been achieved by Co 3 O 4 -based nano-array catalysts featuring low catalytic materials loading. The Ni doping into the Co 3 O 4 lattice has led to enhanced reaction kinetics at low temperature by promoting the surface lattice oxygen activity. In situ DRIFTS investigation in tandem with isotopic oxygen exchange reveals that the propane oxidation proceeds via Mars-van Krevelen mechanism where surface lattice oxygen acts as the active site whereas O 2 in the reaction feed does not directly participate in CO 2 formation. The Ni doping promotes the formation of less stable carbonates on the surface to facilitate the CO 2 desorption. The thermal stability of Ni doped Co 3 O 4 decreases with increased Ni concentration while catalytic activity increases. A balance between enhanced activity and compromised thermal stability shall be considered in the Ni doped Co 3 O 4 nano-array catalysts for low temperature hydrocarbon oxidation. This study provides useful and timely guidance for rational catalyst design toward low temperature catalytic oxidation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization-Inspired Pin-Fin Array for Supercritical Carbon Dioxide Recuperator

Additively manufactured heat exchangers are one possible route to cost-effective sCO 2 power cycles. In this paper, experimental results are obtained for two helical pin fin tubes that were designed following parametric optimization of the fin array. Neither the numerical optimization nor the experimental testing have been previously reported in the literature. The two tube designs were, (1) the optimization inspired design, and (2) the optimization-inspired design with a fin diameter increased by a factor of 2. To characterize the print, the designs were scanned using X-ray computed tomography to measure feature sizes and heat transfer area. The optimization was conducted in a commercial, computational fluid dynamics code. The code solved the Reynolds Averaged Navier-Stokes (RANS) and energy equations with turbulence closure provided by the shear stress transport (SST) k-ω model. In the experiments, the Nusselt number augmentation was measured using the Wilson plot technique and the friction factor was determined with mass flow and pressure drop measurements. The experimental testing indicated that the optimization-inspired design had a friction factor that was four times less than the baseline tube design at equal Nusselt number. Additionally, the optimization-inspired design had a 14% improvement in Nusselt number, at equal friction factor, relative to the best performing computational fluid dynamics (CFD) trial points. Tube design (2), with the larger diameter pin fins, had similar performance, within experimental error, as the tube with the smaller diameter pin fins (1). Both tubes achieved overall fin array efficiencies near 1. A performance factor, V/V 0 , equal to the volume of the enhanced heat exchanger divided by the volume of the baseline (no-fins) heat exchanger, is recommended to quantify internal cooling performance. In conclusion, the experimental shell and tube heat exchanger, using the additively manufactured tube, is competitive with printed circuit heat exchangers in its pressure drop class and could be further improved by optimizing a shell-and-tube heat exchanger utilizing this heat transfer enhancement feature.

42 ENGINEERING↗

X-ray polarimetry with the Polarization Spectroscopic Telescope Array (PolSTAR)

This paper describes the Polarization Spectroscopic Telescope Array (PolSTAR), a mission proposed to NASA’s 2014 Small Explorer (SMEX) announcement of opportunity. PolSTAR measures the linear polarization of 3-50 keV (requirement; goal: 2.5-70 keV) X-rays probing the behavior of matter, radiation and the very fabric of spacetime under the extreme conditions close to the event horizons of black holes, as well as in and around magnetars and neutron stars. The PolSTAR design is based on the technology developed for the Nuclear Spectroscopic Telescope Array (NuSTAR) mission launched in June 2012. In particular, it uses the same X-ray optics, extendable telescope boom, optical bench, and CdZnTe detectors as NuSTAR. The mission has the sensitivity to measure ~1% linear polarization fractions for X-ray sources with fluxes down to ~5 mCrab. This paper describes the PolSTAR design as well as the science drivers and the potential science return

Blazars↗

Discovery of novel antiviral agents directed against the influenza A virus nucleoprotein using photo-cross-linked chemical arrays

The nucleoprotein (NP) of the influenza virus is expressed in the early stage of infection and plays important roles in numerous steps of viral replication. NP is relatively well conserved compared with viral surface spike proteins. This study experimentally demonstrates that NP is a novel target for the development of new antiviral drugs against the influenza virus. First, artificial analogs of mycalamide A in a chemical array bound specifically with high affinity to NP. Second, the compounds inhibited multiplication of the influenza virus. Furthermore, surface plasmon resonance imaging experiments demonstrated that the binding activity of each compound to NP correlated with its antiviral activity. Finally, it was shown that these compounds bound NP within the N-terminal 110-amino acid region but their binding abilities were dramatically reduced when the N-terminal 13-amino acid tail was deleted, suggesting that the compounds might bind to this region, which mediates the nuclear transport of NP and its binding to viral RNA. These data suggest that compound binding to the N-terminal 13-amino acid tail region may inhibit viral replication by inhibiting the functions of NP. Collectively, these results strongly suggest that chemical arrays are convenient tools for the screening of viral product inhibitors.

60 APPLIED LIFE SCIENCES↗

Cobalt nanoparticle-encapsulated carbon nanowire arrays: Enabling the fast redox reaction kinetics of lithium-sulfur batteries

The commercial application of lithium-sulfur batteries is still impeded by the unsatisfying cyclability due to the sluggish reaction kinetics and shuttling effect of polysulfide intermediates. We develop a cobalt nanoparticle-encapsulated carbon nanowire arrays on carbon cloth (CC@Co-CNAs) to enable the fast redox reaction kinetics of the lithium sulfur batteries. The nanowire array-decorated carbon cloth as conductive matrix for sulfur active material could provide highly exposed cobalt nanoparticle active sites, owing to the high length-diameter ratio of the prepared CC@Co-CNAs. The binding affinity between the cobalt nanoparticle-incorporated materials and polysulfide intermediates is enhanced by Co-S bonds, which facilitates the redox reaction of active materials and consequently results in a high sulfur utilization for cathode especially with high sulfur loading. The lithium sulfur battery with CC@Co-CNAs as electrode materials delivers a high initial discharge capacity of 1228 mAh g –1 at 0.25 C, and a high initial discharge capacity of 807 mAh g –1 at 1C with a low capacity fading rate of 0.06% per cycle during 300 cycles. Furthermore, a discharge capacity of 958 mAhg –1 at 0.1 C is achieved for the cell even with a corresponding sulfur loading of 6.2 mg cm –2 .

25 ENERGY STORAGE↗

Microbeam Radiation Therapy: Tissue Dose Penetration and BANG-Gel Dosimetry of Thick-Beams' Array Intelacing

The tissue-sparing effect of parallel, thin (narrower than 100em) synchrotron-generated X-ray planar beams (microbeams) in healthy tissues including the central nervous system (CNS) is known since early 1990s. This, together with a remarkable preferential tumoricidal effect of such beam arrays observed at high doses, has been the basis for labeling the method microbeam radiation therapy (MRT). Recent studies showed that beams as thick as 0.68mm ('thick microbeams') retain part of their sparing effect in the rat's CNS, and that two such orthogonal microbeams arrays can be interlaced to produce an unsegmented field at the target, thus producing focal targeting. We measured the half-value layer (HVL) of our 120-keV median-energy beam in water phantoms, and we irradiated stereotactically bis acrylamide nitrogen gelatin (BANG)-gel-filled phantoms, including one containing a human skull, with interlaced microbeams and imaged them with MRI. A 43-mm water HVL resulted, together with an adequately large peak-to-valley ratio of the microbeams' three-dimensional dose distribution in the vicinity of the 20mmx20mmx20mm target deep into the skull. Furthermore, the 80-20% dose falloff was a fraction of a millimeter as predicted by Monte Carlo simulations. We conclude that clinical MRT will benefit from the use of higher beam energies than those used here, although the current energy could serve certain neurosurgical applications. Furthermore, thick microbeams particularly when interlaced present some advantages over thin microbeams in that they allow the use of higher beam energies and they could conceivably be implemented with high power orthovoltage X-ray tubes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the computation of moments in the Super-Transition-Arrays model for radiative opacity calculations

In the Super-Transition-Array statistical method for the computation of radiative opacity of hot dense matter, the moments of the absorption or emission features involve partition functions with reduced degeneracies, occurring through the calculation of averages of products of subshell populations. Here, in the present work, we discuss several aspects of the computation of such peculiar partition functions, insisting on the precautions that must be taken in order to avoid numerical difficulties. In a previous work, we derived a formula for supershell partition functions, which takes the form of a functional of the distribution of energies within the supershell and allows for fast and accurate computations, truncating the number of terms in the expansion. The latter involves coefficients for which we obtained a recursion relation and an explicit formula. We show that such an expansion can be combined with the recurrence relation for shifted partition functions. We also propose, neglecting the effect of fine structure as a first step, a positive-definite formula for the Super-Transition-Array moments of any order, providing an insight into the asymmetry and sharpness of the latter. The corresponding formulas are free of alternating sums. Several ways to speed up the calculations are also presented.

74 ATOMIC AND MOLECULAR PHYSICS↗

In Vivo Dosimetry Using a Linear Mosfet-Array Dosimeter to Determine the Urethra Dose In {sup 125}I Permanent Prostate Implants

Purpose: In vivo dosimetry during brachytherapy of the prostate with {sup 125}I seeds is challenging because of the high dose gradients and low photon energies involved. We present the results of a study using metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to evaluate the dose in the urethra after a permanent prostate implantation procedure. Methods and Materials: Phantom measurements were made to validate the measurement technique, determine the measurement accuracy, and define action levels for clinical measurements. Patient measurements were performed with a MOSFET array in the urinary catheter immediately after the implantation procedure. A CT scan was performed, and dose values, calculated by the treatment planning system, were compared to in vivo dose values measured with MOSFET dosimeters. Results: Corrections for temperature dependence of the MOSFET array response and photon attenuation in the catheter on the in vivo dose values are necessary. The overall uncertainty in the measurement procedure, determined in a simulation experiment, is 8.0% (1 SD). In vivo dose values were obtained for 17 patients. In the high-dose region (> 100 Gy), calculated and measured dose values agreed within 1.7% {+-} 10.7% (1 SD). In the low-dose region outside the prostate (< 100 Gy), larger deviations occurred. Conclusions: MOSFET detectors are suitable for in vivo dosimetry during {sup 125}I brachytherapy of prostate cancer. An action level of {+-} 16% (2 SD) for detection of errors in the implantation procedure is achievable after validation of the detector system and measurement conditions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In Vivo Dosimetry With a Linear MOSFET Array to Evaluate the Urethra Dose During Permanent Implant Brachytherapy Using Iodine-125

Purpose: To develop a technique to monitor the dose rate in the urethra during permanent implant brachytherapy using a linear MOSFET array, with sufficient accuracy and without significantly extending the implantation time. Methods and Materials: Phantom measurements were performed to determine the optimal conditions for clinical measurements. In vivo measurements were performed in 5 patients during the {sup 125}I brachytherapy implant procedure. To evaluate if the urethra dose obtained in the operating room with the ultrasound transducer in the rectum and the patient in treatment position is a reference for the total accumulated dose; additional measurements were performed after the implantation procedure, in the recovery room. Results: In vivo measurements during and after the implantation procedure agree very well, illustrating that the ultrasound transducer in the rectum and patient positioning do not influence the measured dose in the urethra. In vivo dose values obtained during the implantation are therefore representative for the total accumulated dose in the urethra. In 5 patients, the dose rates during and after the implantation were below the maximum dose rate of the urethra, using the planned seed distribution. Conclusion: In vivo dosimetry during the implantation, using a MOSFET array, is a feasible technique to evaluate the dose in the urethra during the implantation of {sup 125}I seeds for prostate brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of machine learning and electrical resistivity arrays to inverse modeling for locating and characterizing subsurface targets

Here, this study evaluates the performance of multiple machine learning (ML) algorithms and electrical resistivity (ER) arrays for inversion with comparison to a conventional Gauss-Newton numerical inversion method. Four different ML models and four arrays were used for the estimation of only six variables for locating and characterizing hypothetical subsurface targets. The combination of dipole-dipole with Multilayer Perceptron Neural Network (MLP-NN) had the highest accuracy. Evaluation showed that both MLP-NN and Gauss-Newton methods performed well for estimating the matrix resistivity while target resistivity accuracy was lower, and MLP-NN produced sharper contrast at target boundaries for the field and hypothetical data. Both methods exhibited comparable target characterization performance, whereas MLP-NN had increased accuracy compared to Gauss-Newton in prediction of target width and height, which was attributed to numerical smoothing present in the Gauss-Newton approach. MLP-NN was also applied to a field dataset acquired at U.S. DOE Hanford site.

54 ENVIRONMENTAL SCIENCES↗

Modifying the strength and strain concentration profile within collagen scaffolds using customizable arrays of poly-lactic acid fibers

Here, the tendon-to-bone junction is a highly specialized tissue which dissipates stress concentrations between mechanically dissimilar tendon and bone. Upon injury, the local heterogeneities across this insertion are not regenerated, leading to poor functional outcomes such as formation of scar tissue at the insertion and re-failure rates exceeding 90%. Although current tissue engineering methods are moving towards the development of spatially-graded biomaterials to begin to address these injuries, significant opportunities remain to engineer the often complex local mechanical behavior of such biomaterials to enhance their bioactivity. Here, we describe the use of three-dimensional printing techniques to create customizable arrays of poly-lactic acid (PLA) fibers that can be incorporated into a collagen scaffold under development for tendon bone junction repair. Notably, we use additive manufacturing concepts to generate arrays of spatially-graded fibers from biodegradable PLA that are incorporated into collagen scaffolds to create a collagen-PLA composite. We demonstrate the ability to tune the mechanical performance of the fiber-scaffold composite at the bulk scale. We also demonstrate the incorporation of spatially-heterogeneous fiber designs to establish non-uniform local mechanical performance of the composite biomaterial under tensile load, a critical element in the design of multi-compartment biomaterials for tendon-to-bone regeneration applications. Together, this work highlights the capacity to use multi-scale composite biomaterials to control local and bulk mechanical properties, and provides key insights into design elements under consideration for mechanically competent, multi-tissue regeneration platforms.

3D printing↗

Guided skyrmion motion along pinning array interfaces

We examine ac driven skyrmions interacting with the interface between two different obstacle array structures. We consider drive amplitudes at which skyrmions in a bulk obstacle lattice undergo only localized motion and show that when an obstacle lattice interface is introduced, directed skyrmion transport can occur along the interface. The skyrmions can be guided by a straight interface and can also turn corners to follow the interface. For a square obstacle lattice embedded in a square pinning array with a different obstacle radius, we find that skyrmions can undergo transport in all four primary symmetry directions under the same fixed ac drive. We map where localized or translating motion occurs as a function of the ac driving parameters. Our results suggest a new method for controlling skyrmion motion based on transport along obstacle lattice interfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗