Search NASA⌕ Search

SEARCH · Search NASA

Results for “condition based monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Wireless Sensor Node for Autonomous Monitoring and Alerts in Remote Environments

A method, apparatus, system, and computer program products provides personal alert and tracking capabilities using one or more nodes. Each node includes radio transceiver chips operating at different frequency ranges, a power amplifier, sensors, a display, and embedded software. The chips enable the node to operate as either a mobile sensor node or a relay base station node while providing a long distance relay link between nodes. The power amplifier enables a line-of-sight communication between the one or more nodes. The sensors provide a GPS signal, temperature, and accelerometer information (used to trigger an alert condition). The embedded software captures and processes the sensor information, provides a multi-hop packet routing protocol to relay the sensor information to and receive alert information from a command center, and to display the alert information on the display.

Monacos, Steve P.↗

Effects of Polar Stratospheric Clouds in the Nimbus 7 LIMS Version 6 Data Set

The historic Limb Infrared Monitor of the Stratosphere (LIMS) measurements of 1978-1979 from the Nimbus 7 satellite were re-processed with Version 6 (V6) algorithms and archived in 2002. The V6 data set employs updated radiance registration methods, improved spectroscopic line parameters, and a common vertical resolution for all retrieved parameters. Retrieved profiles are spaced about every 1.6 of latitude along orbits and include the additional parameter of geopotential height. Profiles of O3 are sensitive to perturbations from emissions of polar stratospheric clouds (PSCs). This work presents results of implementing a first-order screening for effects of PSCs using simple algorithms based on vertical gradients of the O3 mixing ratio. Their occurrences are compared with the co-located, retrieved temperatures and related to the temperature thresholds needed for saturation of H2O and/or HNO3 vapor onto PSC particles. Observed daily locations where the major PSC screening criteria are satisfied are validated against PSCs observed with the Stratospheric Aerosol Monitor (SAM) II experiment also on Nimbus 7. Remnants of emissions from PSCs are characterized for O3 and HNO3 following the screening. PSCs may also impart a warm bias in the co-located LIMS temperatures, but by no more than 1-2K at the altitudes of where effects of PSCs are a maximum in the ozone; thus, no PSC screening was applied to the V6 temperatures. Minimum temperatures vary between 187 and 194K and often occur 1 to 2 km above where PSC effects are first identified in the ozone (most often between about 21 and 28 hPa). Those temperature-pressure values are consistent with conditions for the existence of nitric acid trihydrate (NAT) mixtures and to a lesser extent of super-cooled ternary solution (STS) droplets. A local, temporary uptake of HNO3 vapor of order 1-3 ppbv is indicated during mid-January for the 550K surface. Seven-month time series of the distributions of LIMS O3 and HNO3 are shown based on their gridded Level 3 data following the PSC screening. Zonal coefficients of both species are essentially free of effects from PSCs on the 550K surface, based on their average values along PV contours and in terms of equivalent latitude. Remnants of PSCs are still present in O3 on the 450K surface during mid- January. It is judged that the LIMS Level 3 data are of good quality for analyzing the larger-scale, stratospheric chemistry and transport processes during the Arctic winter of 1978- 1979.

Remsberg, Ellis↗

The inter- and intrafraction reproducibilities of three common IMRT delivery techniques

Purpose: Intensity modulated radiation therapy (IMRT) treatment delivery requires higher precision than conventional 3D treatment delivery because of the sensitivity of the resulting dose to small geometric misalignment of the modulated beamlets. The chosen treatment delivery technique will affect the treatment precision in different ways, based on the characteristics of the delivery method. Delivery using a multileaf collimator (MLC) can reduce treatment time and therapist workload, but typically requires a greater number of monitor units and the fields are prone to both systematic and random leaf positioning errors. An alternative to MLC-based fields, patient specific brass compensators, do not suffer from these leaf positioning errors. In our study, we set out to investigate which delivery method will provide the highest levels of dosimetric reproducibility and the minimum amount of interfraction variability. Methods: In our study, a seven field IMRT plan for a head and neck treatment was created using the Pinnacle{sup 3} treatment planning system and the intensity maps for each field were obtained. The intensity maps of the fields were delivered with a Varian 2100C/D linear accelerator, using solid compensators and sliding window (SW) and step-and-shoot (SS) MLC segments. Three fields were selected from the seven-beam IMRT plan for comparison. Analysis was carried out using the MatriXX ion chamber array, radiochromic film, and Varian dynalog files. Results: Our results show that the error in MLC leaf positioning has no gantry angle dependence. The compensator and SW deliveries showed excellent agreement, even when stricter than usual gamma criteria were applied. However, we noted that under these strict conditions, the SS fields had at least ten times more pixels out of range than did the compensators. When using step-and-shoot MLC fields, it was observed that the increase in dose rate or the increase of MU/segment degrades the quality of the plan. Analysis of the dynalog files showed that while each individual field had its own propensity for error, all fields showed the same trend: a greater percentage of time the leaves are out of position as dose rate increases, MUs decrease, or both. Conclusions: The compensator-based field and both types of MLC-based fields have MatriXX results that are within the clinically acceptable tolerance of 3% dose difference and 2 mm DTA. However, when the criteria are tightened, it becomes evident that the compensators have a definite advantage over their comparable MLC-based competitors in terms of interfraction reproducibility. Fewer monitor units are required to deliver each portal, potentially improving patient outcomes and reducing unwanted side effects to both patients and therapists. In centers without MLC, compensators represent a simple and cost effective way to offer patients state of the art treatment. Based on the results of this study, compensator-based IMRT is a reliable, viable option for use in clinics both with and without MLC-equipped linacs.

61 RADIATION PROTECTION AND DOSIMETRY↗

Origin and mitigation of wind noise on balloon-borne infrasound microbarometers

High-altitude monitoring of low-frequency acoustic waves (infrasound) on Earth has regained prominence in recent years, primarily driven by improvements in light-weight sensor technology and advances in scientific ballooning techniques. Balloon-borne infrasound monitoring is also being proposed as a remote sensing technique for planetary exploration. Contrary to ground-based infrasound monitoring, the infrasound noise background in the stratosphere as measured by a balloon remains uncharacterized and the efficacy of wind noise mitigation filters has not been investigated. In this study, an analysis of pressure data collected using infrasound microbarometers during the flight of a long-duration zero pressure balloon is presented. Here, a dramatic reduction of background noise in the stratosphere is demonstrated and it is shown that wind noise mitigation filters are not effective at reducing wind noise under these conditions. Results from this study demonstrate stratospheric balloons as a low-noise platform for infrasound monitoring and motivate the development of improved noise mitigation tools.

47 OTHER INSTRUMENTATION↗

Integrated planning and scheduling for Earth science data processing

Several current NASA programs such as the EOSDIS Core System (ECS) have data processing and data management requirements that call for an integrated planning and scheduling capability. In this paper, we describe the experience of applying advanced scheduling technology operationally, in terms of what was accomplished, lessons learned, and what remains to be done in order to achieve similar successes in ECS and other programs. We discuss the importance and benefits of advanced scheduling tools, and our progress toward realizing them, through examples and illustrations based on ECS requirements. The first part of the paper focuses on the Data Archive and Distribution (DADS) V0 Scheduler. We then discuss system integration issues ranging from communication with the scheduler to the monitoring of system events and re-scheduling in response to them. The challenge of adapting the scheduler to domain-specific features and scheduling policies is also considered. Extrapolation to the ECS domain raises issues of integrating scheduling with a product-generation planner (such as PlaSTiC), and implementing conditional planning in an operational system. We conclude by briefly noting ongoing technology development and deployment projects being undertaken by HTC and the ISTB.

Boddy, Mark↗

Management of Asymptomatic Renal Stones in Astronauts

Introduction: Management guidelines were created to screen and manage asymptomatic renal stones in U.S. astronauts. The risks for renal stone formation in astronauts due to bone loss and hypercalcuria are unknown. Astronauts have a stone risk which is about the same as commercial aviation pilots, which is about half that of the general population. However, proper management of this condition is still crucial to mitigate health and mission risks in the spaceflight environment. Methods: An extensive review of the literature and current aeromedical standards for the monitoring and management of renal stones was done. The NASA Flight Medicine Clinic's electronic medical record and Longitudinal Survey of Astronaut Health were also reviewed. Using this work, a screening and management algorithm was created that takes into consideration the unique operational environment of spaceflight. Results: Renal stone screening and management guidelines for astronauts were created based on accepted standards of care, with consideration to the environment of spaceflight. In the proposed algorithm, all astronauts will receive a yearly screening ultrasound for renal calcifications, or mineralized renal material (MRM). Any areas of MRM, 3 millimeters or larger, are considered a positive finding. Three millimeters approaches the detection limit of standard ultrasound, and several studies have shown that any stone that is 3 millimeters or less has an approximately 95 percent chance of spontaneous passage. For mission-assigned astronauts, any positive ultrasound study is followed by low-dose renal computed tomography (CT) scan, and flexible ureteroscopy if CT is positive. Other specific guidelines were also created. Discussion: The term "MRM" is used to account for small areas of calcification that may be outside the renal collecting system, and allows objectivity without otherwise constraining the diagnostic and treatment process for potentially very small calcifications of uncertain significance. However, a small asymptomatic MRM or stone within the renal collecting system may become symptomatic, and so affect launch and flight schedules, cause incapacitation during flight, and ultimately require medical evacuation. For exploration class missions, evacuation is unlikely. The new screening and management algorithm allows better management of mission risks, and will define the true incidence of renal stones in U.S. astronauts. This information will be used to refine future screening, countermeasures and treatment methods; and will also inform the needed capabilities to be flown on exploration-class missions.

Reyes, David↗

Management of Asymptomatic Renal Stones in Astronauts

Introduction: Management guidelines were created to screen and manage asymptomatic renal stones in U.S. astronauts. The risks for renal stone formation in astronauts due to bone loss and hypercalcuria are unknown. Astronauts have a stone risk which is about the same as commercial aviation pilots, which is about half that of the general population. However, proper management of this condition is still crucial to mitigate health and mission risks in the spaceflight environment. Methods: An extensive review of the literature and current aeromedical standards for the monitoring and management of renal stones was done. The NASA Flight Medicine Clinic's electronic medical record and Longitudinal Survey of Astronaut Health were also reviewed. Using this work, a screening and management algorithm was created that takes into consideration the unique operational environment of spaceflight. Results: Renal stone screening and management guidelines for astronauts were created based on accepted standards of care, with consideration to the environment of spaceflight. In the proposed algorithm, all astronauts will receive a yearly screening ultrasound for renal calcifications, or mineralized renal material (MRM). Any areas of MRM, 3 millimeters or larger, are considered a positive finding. Three millimeters approaches the detection limit of standard ultrasound, and several studies have shown that any stone that is 3 millimeters or less has an approximately 95 percent chance of spontaneous passage. For mission-assigned astronauts, any positive ultrasound study is followed by low-dose renal computed tomography (CT) scan, and flexible ureteroscopy if CT is positive. Other specific guidelines were also created. Discussion: The term "MRM" is used to account for small areas of calcification that may be outside the renal collecting system, and allows objectivity without otherwise constraining the diagnostic and treatment process for potentially very small calcifications of uncertain significance. However, a small asymptomatic MRM or stone within the renal collecting system may become symptomatic, and so affect launch and flight schedules, cause incapacitation during flight, and ultimately require medical evacuation. For exploration class missions, evacuation is unlikely. The new screening and management algorithm allows better management of mission risks, and will define the true incidence of renal stones in U.S. astronauts. This information will be used to refine future screening, countermeasures and treatment methods; and will also inform the needed capabilities to be flown on exploration-class missions.

Reyes, David↗

EVA Swab Kit: Tools and Techniques for Collecting Aseptic Samples from Crewed Space Missions

Introduction: When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed spacecraft meet planetary protection requirements—and to protect our science from human contamination—we'll need to assess and verify whether micro-organisms may be leaking/venting from our spacesuits. This requires collecting samples under Extravehicular Activity (EVA) conditions. Detailed, systematic research on forward contamination from robotic spacecraft has been steadily progressing since the Viking missions, but systematic studies of contamination from space suits has not been conducted in many years. The modern EMU (Extravehicular Mobility Unit) suit used by NASA is designed to leak at rates as high as 100 cc/min. Before humans land on Mars there is a critical need to understand the types and quantities of microbes that could be introduced via space suits. The Human Forward Contamination Assessment team at NASA’s Johnson Space Center (JSC) has developed a prototype EVA swab tool [1,2,3,4] designed for use in space to sample cleaned and uncleaned space suits to determine the present day microbial load and eventually the rate of leakage. The ability to assess microbial leakage early in advanced space suit and life support system design cycles will help avoid costly hardware redesign later. Test Objectives: The primary objective of EMU testing was to characterize the type of micro-organisms typically found on or near selected suit pressure joints under suit differential pressure conditions. Most human-borne microbes can fit through a 0.5 to 1.0 µm gap. Knowing which joints are more likely to leak will inform hardware design decisions. Knowing which types of micro-organisms may leak from EVA suits provides a basis for subsequent studies to characterize the viability of those organisms under destination conditions, as well as how far they might spread through natural or human-influenced processes. That data, in turn, will inform exploration mission operations and hardware design. The secondary objective of testing was to evaluate the interface between a fully suited test subject and the EVA swab tool at vacuum. Bulky EVA suits can restrict movement and limit visibility through the helmet visor. Fully suited testing is important for identifying tool design issues prior to flight. At exploration destinations, such as Mars, suited crew may be required to periodically sample their suits as part of an environmental monitoring protocol. Suit Microbial Sampling Results: This report details results of microbial swabs collected from current flight suit configurations worn by crew members assigned to upcoming ISS expedition missions as well as swabs collected from prototype suits intended for use on the Orion spacecraft. These tests were intended to characterize the types of contaminants found on flight suits under current, typical handling conditions. No attempt was made to change suit handling procedures, provide additional sterilization, or to limit typical potential contaminant sources. Using culture based techniques, we cultivated 235 CFU (colony forming units) comprised of 26 bacterial species and one fungal species on the outside of the suits. The fungal species and 14 of the bacterial species were unique to the suit surfaces and were not detected in any of the background samples collected within the chambers. We sequenced 755,434 ribosomal fragments on all of the suit surfaces from swab samples. 557,016 of these sequences represent DNA that survived at least 4 hours at vacuum. These sequences formed 2,464 OTU's (Operational Taxonomic Units, 97% similarity) showing low diversity in the samples. The most abundant sequences that survived vacuum belong to the genera Staphyloccocus, Ralstona, Bacillus and Rhodobacter all of which are common to the human microbiome. [5] See Danko et al., (2021) for more complete details of these first analyses. Further analysis of EVA suit materials with respect to the efficacy of various cleaning protocols and engineered containment solutions is planned to inform suit design for NASA’s Artemis Moon to Mars program crew testing. Swab Tool Function Results: The kit was demonstrated for fit and function in suited subject vacuum tests to determine how well the tool worked as an aseptic microbial sampling device as well as to identify any design elements that could be upgraded for EVA task specific improvement. It was found that sample acquisition efficacy could be enhanced by redesign of the sample canister to end-effector interface. Several modifications of the sample caddy assemblies to optimize EVA safety and functionality were also identified. Consequently, fabrication of the redesigned sample canister to end-effector assembly interfaces and and the sample caddy assemblies are required. Fabrication of sixteen flight sample canister assemblies (8 per each of two EVA Swab Kits) and two sample caddy assemblies are in process to be followed by hardware testing and certification to produce two flight-certified EVA Swab Kits for transport to ISS no earlier than summer of 2022. Sampling Strategy: The International Space Station is an ideal testbed for systematic studies of contamination from crewed vehicles since it has been continuously occupied for 20 years and exposed to non-terrestrial conditions. We will sample the exterior of the ISS during EVA using a purpose-built swab tool capable of maintaining sterility while undergoing temperature changes from -151 to +121°C under hard vacuum. Prior to each EVA, the project team will work with ISS mission managers to identify precise sampling locations, which will vary by EVA based on the translation paths and worksites scheduled for that particular EVA. Ideally, translation path handrails and areas near ECLSS (Environmental Control and Life Support System) external vent openings on a spacecraft would be assessed. There are currently more than a dozen ECLSS external vents on the ISS. Some are connected to systems that vent waste products, while others are intended to equalize cabin pressure. As EVA opportunity allows, microbial samples from any of these external vents would provide a valuable data point, though some will be more useful than others. Four criteria have been identified to help prioritize sampling sites near vents: • EVA Accessibility: To minimize cost, it is desired to piggy-back onto a planned EVA. Therefore, the sampling location must be readily accessible by an EVA crew • Type of Vented Products: Vent products that have been in direct contact with crew, such as cabin air, are more likely to contain microorganisms than vent products associated with isolated systems, such as experiment module combustion products. • Mass of Vented Products: Higher-flow vents are more likely to contain detectible levels of microbial contaminants than lower-flow vents. • Local Environment: Sample locations with relatively benign local conditions, such as warm surfaces shielded from direct ultraviolet (UV) radiation exposure, may be more likely to support microbial growth than locations with harsher local environmental conditions. Because EVA accessibility is the most important criteria, the proposal team worked with an astronaut and flight controllers using the Dynamic Onboard Ubiquitous Graphics (DOUG) tool. The DOUG virtual environment allows an operator to “fly” around the current ISS vehicle configuration to assess EVA translation paths, attach points, and keep-out zones. While analysis on station or rapid return to Earth would be preferable, samples collected from the exterior of the ISS have already been exposed to temperature variations between -157 and +121 °C as well as hard vacuum. Therefore, they should be fairly stable and robust. We hypothesize that samples collected from the ISS exterior could be stored for up to 6 months at -80°C without degradation. Sample canisters will be returned to Earth while frozen at -80°C for analysis, and sterilized canisters can be re-flown back to ISS to support additional sampling opportunities Relevance to NASA Exploration Objectives: These data will allow us to identify new or improved methods, technologies, and procedures for spacecraft sterilization and leakage mitigation to minimize the amount of contamination introduced to the environment by human explorers. This work is funded by NASA research grant: NNH18ZDA001N-PPR References: [1] Bell, M.S. et al. (2015) LPS XLVI, Abst. #1832 [2] Rucker et al. (2018) 42nd COSPAR (PPP.3) [3] Bell, M.S. et al. (2019) Mars Extant Life Conference, Abst. #5096.[4] Bell, M.S. et al., (2020) 43rd COSPAR (BO.2).[5] Danko D, et.al.,(2021)Front.Microbiol.12:608478.

Mary Suzanne Bell↗

Lidar and UAS Measurements of Winds for the NASA Advanced Air Mobility Mission

The envisioned future of Advanced Air Mobility involves low-altitude operation of a new class of air vehicles. The low altitudes of the flight paths would have these vehicles spending most of their operation in conditions where unpredictable wind and turbulence effects may occur. Wind measurements will hence be critical to ensure safe and efficient operations for AAM. Such wind measurement could be used as a monitoring system for warning of hazardous wind events, as data input to forecasting models, or as a research tool to understand wind effects in complex environments. To meet this need NASA is evaluating wind sensing technologies with a capability to probe the atmospheric boundary layer. Doppler lidar is a leading candidate ground-based sensor, as shown by the decades-long history of being an effective tool for many wind studies. However, there is a need to re-assess the Doppler wind lidars for the AAM application which involves evaluating wind effects as vehicles operate in and out of vertiports, notably regarding spatial resolution. Meeting the needs for spatial resolution may involve the use of dual-Doppler techniques, rather than just single Doppler lidar. The study was furthermore motivated by looking toward the future of AAM, in which the air vehicles involved can also provide wind measurements. Airborne wind measurements, obtained directly from vehicle-mounted anemometers or indirectly from vehicle navigation data, offer a means to compare remotely sensed wind lidar with in-situ measurements. The following sections report on results of wind measurements obtained using lidar and the small uninhabited aircraft systems (sUAS’s) operating in the same volume of air.

Adam Medina↗

Edible oil and MicroCED{sup TM} treatability study for enhanced attenuation of cVOCs at P Area, Savannah River Site - 15364

The purpose of the study is to evaluate the capability of Micro-organism Chlorinated Ethene Destruction (MicroCED) to degrade chlorinated volatile organic compounds (cVOCs) in an existing groundwater plume at the Savannah River Site (SRS). MicroCED is similar to other commercially sold Dehalococcoides microbes (i.e., BAV-1 and KB-1) that are used to degrade cVOCs in support of groundwater cleanup actions. However, a primary difference is that this microbe is indigenous to the Twin Lakes area near C Area at the SRS. The Savannah River National Laboratory (SRNL) and Clemson University have been studying the capability and toxicology of the microbe for many years. To assess the potential of MicroCED in an environmental setting, a Treatability Study [5] was developed and submitted to South Carolina Department of Health and Environmental Control (SCDHEC). Approval was received and implementation of the study was conducted during the dates of September 14, 2010 and September 30, 2011. During September - October 2010, approximately 423,966 liters of amendments (pH buffer [AquaBupH{sup TM}] and emulsified oil [EOS{sup TM}) and chase water were injected into a cVOC groundwater plume at P Area at a depth of 26 - 30.5 m below land surface. The amendments were injected to raise the groundwater pH and to convert an oxygenated groundwater system to a reducing environment better suited for MicroCED. MicroCED was injected in January and August 2011; however, only 140 liters of the 6,246 liters needed were injected. The insufficient number of growth chambers and project schedule limited the ability to grow and maintain the required amount of MicroCED needed for the study. Groundwater monitoring of the injection wells and monitoring points were conducted monthly to evaluate and assess changes to the existing cVOC groundwater plumes. Field data collected from the injection wells demonstrated a reducing environment suitable for MicroCED growth. However, nearby monitoring points located within the injection field did not indicate a change in groundwater chemistry. Further analysis of the injected material showed that the actual radius of influence was less than assumed. This resulted in conditions favorable for MicroCED growth to be located near the injection wells versus over a larger area, as expected. Data collected indicates biodegradation of the cVOCs via the MicroCED is encouraging but inconclusive. This could be a result of the insufficient quantity of MicroCED injected and limited time frame of monitoring after MicroCED injections. However, considering that the data were collected within six (6) months of the first MicroCED injection it could also be plausible that microbial growth is limited and is not measurable based on the time frame and quantity of microbes that were injected. But, concentrations of TCE metabolic products have been observed to increase as the study progressed and were most evident after the first MicroCED injection. Due to timing of the second MicroCED injection in August 2011, there are no data available to evaluate subsequent effects of this injection on cVOC concentrations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Database Integrity Monitoring for Synthetic Vision Systems Using Machine Vision and SHADE

In an effort to increase situational awareness, the aviation industry is investigating technologies that allow pilots to visualize what is outside of the aircraft during periods of low-visibility. One of these technologies, referred to as Synthetic Vision Systems (SVS), provides the pilot with real-time computer-generated images of obstacles, terrain features, runways, and other aircraft regardless of weather conditions. To help ensure the integrity of such systems, methods of verifying the accuracy of synthetically-derived display elements using onboard remote sensing technologies are under investigation. One such method is based on a shadow detection and extraction (SHADE) algorithm that transforms computer-generated digital elevation data into a reference domain that enables direct comparison with radar measurements. This paper describes machine vision techniques for making this comparison and discusses preliminary results from application to actual flight data.

Cooper, Eric G.↗

Acoustic Environment of Admiralty Inlet: Broadband Noise Measurements

Admiralty Inlet has been selected as a potential tidal energy site. It is located near shipping lanes, is a highly variable acoustic environment, and is frequented by the highly endangered southern resident killer whale (SRKW). Resolving environmental impacts is the first step to receiving approval to deploy tidal turbines at Admiralty Inlet. Of particular concern is the potential for blade strike or other negative interactions between the SRKW and the tidal turbine. A variety of technologies including passive and active monitoring systems are being considered as potential tools to determine the presence of SRKW in the vicinity of the turbines. Broadband noise level measurements are critical for the determination of design and operation specifications of all marine and hydrokinetic energy capture technologies. Acoustic environment data at the proposed site was acquired at different depths using a cabled vertical line array (VLA) with four calibrated hydrophones. The sound pressure level (SPL) power spectrum density was estimated based on the fast Fourier transform. This study describes the first broadband SPL measurements for this site at different depths with frequency ranging from 10 kHz to 480 kHz in combination with other information. To understand the SPL caused by this bedload transport, three different pressure sensors with temperature and conductivity were also assembled on the VLA to measure the conditions at the hydrophone deployment depth. The broadband SPL levels at frequency ranges of 3 kHz to 7 kHz as a function of depth were estimated. Only the hydrophone at an average depth of 40 m showed the strong dependence of SPL with distance from the bottom, which was possibly caused by the cobbles shifting on the seabed. Automatic Identification System data were also studied to understand the SPL measurements.

16 TIDAL AND WAVE POWER↗

Runtime Assurance Protection for Advanced Turbofan Engine Control

This paper describes technical progress made in the application of run time assurance (RTA) methods to turbofan engines with advanced propulsion control algorithms that are employed to improve engine performance. It is assumed that the advanced algorithms cannot be fully certified using current verification and validation approaches and therefore need to be continually monitored by an RTA system that ensures safe operation. However, current turbofan engine control systems utilize engine protection logic for safe combustion dynamics and stable airflow through the engine. It was determined that the engine protection logic should continue to be used to provide system safety and should be considered as a part of the overall RTA system. The additional function that an RTA system provides is to perform diagnostics on anomalous conditions to determine if these conditions are being caused by errors in the advanced controller. If this is the case, the RTA system switches operation to a trusted reversionary controller. Initial studies were performed to demonstrate this benefit. The other focus was to improve the performance of the engine protection logic, which was deemed too conservative and reduced engine performance during transient operations. It was determined that the conservative response was due to poor tuning of one of the controller channels within the protection logic. An automatic tuning algorithm was implemented to optimize the protection logic control gains based on minimizing tracking error. Improved tracking responses were observed with no change to the existing protection logic control architecture.

runtime monitoring↗

Collisions of Ir oxide nanoparticles with carbon nanopipettes: Experiments with one nanoparticle

Investigating the collisions of individual metal nanoparticles (NPs) with electrodes can provide new insights into their electrocatalytic behavior, mass transport, and interactions with surfaces. Here we report a new experimental setup for studying NP collisions based on the use of carbon nanopipettes to enable monitoring multiple collision events involving the same NP captured inside the pipet cavity. A patch clamp amplifier capable of measuring pA-range currents on the microsecond time scale with a very low noise and stable background was used to record the collision transients. The analysis of current transients produced by oxidation of hydrogen peroxide at one IrO x NP provided information about the origins of deactivation of catalytic NPs and the effects of various experimental conditions on the collision dynamics. Lastly, high-resolution TEM of carbon pipettes was used to attain better understanding of the NP capture and collisions.

36 MATERIALS SCIENCE↗

Risk aware net load balancing in micro grids with high DER penetration

The rapid transformation of micro grids due to the accelerated integration of renewables, storage systems and IoT enabled monitoring and control has opened up new opportunities as well as challenges. Future micro grids will be characterized by high DER penetration and will require sophisticated net load balancing frameworks which explicitly consider the errors in prediction of load and generation due to uncertainty in weather conditions while making decisions. Traditional techniques for grid net load management which rely on isolated shaping of load and supply curves are inadequate and inefficient. For micro grids with high PV penetration, the intermittent and unpredictable nature of PV based energy generation can lead to dramatic and sudden supply demand imbalances thus requiring a holistic framework for balancing net load over the entire horizon. In this paper, we develop a sequential decision making framework for net load management that optimally balances the usage of storage and energy market transactions as a mechanism for mitigating supply demand imbalances (net load imbalances) over the horizon. Our framework specifically accounts for prediction uncertainty of future net load imbalances and minimizes the tail end risk of storage shortfall at the end of the horizon. Using qualitative analysis, we show that our framework achieves its objective of minimum cost net load balancing while accounting for the tail end risk.

14 SOLAR ENERGY↗

Scale-Up Information for Gas-Phase Ammonia Treatment of Uranium in the Vadose Zone at the Hanford Site Central Plateau

Uranium is present in the vadose zone at the Hanford Central Plateau and is of concern for protection of groundwater. The Deep Vadose Zone Treatability Test Plan for the Hanford Central Plateau identified gas-phase treatment and geochemical manipulation as potentially effective treatment approaches for uranium and technetium in the Hanford Central Plateau vadose zone. Based on laboratory evaluation, use of ammonia vapor was selected as the most promising uranium treatment candidate for further development and field testing. While laboratory tests have shown that ammonia treatment effectively reduces the mobility of uranium, additional information is needed to enable deployment of this technology for remediation. Of importance for field applications are aspects of the technology associated with effective distribution of ammonia to a targeted treatment zone, understanding the fate of injected ammonia and its impact on subsurface conditions, and identifying effective monitoring approaches. In addition, information is needed to select equipment and operational parameters for a field design. As part of development efforts for the ammonia technology for remediation of vadose zone uranium contamination, field scale-up issues were identified and have been addressed through a series of laboratory and modeling efforts. This report presents a conceptual description for field application of the ammonia treatment process, engineering calculations to support treatment design, ammonia transport information, field application monitoring approaches, and a discussion of processes affecting the fate of ammonia in the subsurface. The report compiles this information from previous publications and from recent research and development activities. The intent of this report is to provide technical information about these scale-up elements to support the design and operation of a field test for the ammonia treatment technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Initial development of a method for correlating indentation test results to damage accumulation in high temperature structural materials

This report describes an experimental approach based on microindentation creep or relaxation tests for assessing the remaining creep life of a sample material. The objective for this experimental program is to complement the development of passively loaded in situ surveillance specimens. These surveillance specimens could be placed in future advanced reactors to assess the degradation of structural properties, primary creep and creep-fatigue life, when the material is exposed to actual reactor operating conditions. The specimens and the corresponding indentation test protocol could form the basis of a structural health monitoring program designed to ensure the safe continued operation of the component given the relatively unknown effect of the reactor coolant chemistry, radiation exposure, and other environmental effects on the material properties of the constituent structural materials.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Jet transport flight operations using cockpit display of traffic information during instrument meteorological conditions: Simulation evaluation

A simulation study was undertaken to evaluate flight operations using cockpit display of traffic information (CDTI) in a conventional jet transport aircraft. Eight two-person airline flight crews participated as test subjects flying simulated terminal area approach and departure operations under instrument meteorological conditions (IMC). A fixed-base cockpit simulator configured with a full complement of conventional electromechanical instrumentation to permit full workload operations was utilized. Traffic information was displayed on a color cathode-ray tube (CRT) mounted above the throttle quadrant in the typical weather radar location. A transparent touchpanel overlay was utilized for pilot interface with the display. Air traffic control (ATC) simulation included an experienced controller and full partyline radio environment for evaluation of pilot-controlled self-separation and traffic situation monitoring tasks. Results of the study revealed the CDTI to be well received by the test subjects as a useful system which could be incorporated into an existing jet transport cockpit. Crew coordination and consistent operating procedures were identified as important considerations in operational implementation of traffic displays. Cockpit workload was increased with active CDTI tasks. However, all test subjects rated the increase to be acceptable.

Williams, David H.↗