Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Coordinated Use of Smart Inverters with Legacy Voltage Regulating Devices in Distribution Systems with High Distributed PV Penetration — Increase CVR Energy Savings

This paper studies the coordinated use of smart inverters with legacy voltage regulating devices to help increase the energy savings from conservation voltage reduction (CVR) in distribution systems with high photovoltaic penetration. Two voltage optimization algorithms are developed to evaluate the CVR benefit by considering two types of smart inverter functions: aggregated reactive power control and autonomous volt/VAR control. In each algorithm, smart inverters are coordinately controlled with the operation of legacy voltage regulating devices including load tap changers and capacitor banks. Both algorithms are tested on representative utility distribution system models. In conclusion, simulation results demonstrate that the proposed algorithms can achieve around 1.8-3.6% energy savings when only using legacy voltage regulating devices and an additional 0.3-0.9% when adding smart inverters.

14 SOLAR ENERGY↗

Supercapacitor to Provide Ancillary Services: Preprint

Supercapacitor technology has reached a level of maturity as a viable energy storage option available to support a modern electric power system grid; however, its application is still limited because of its energy capacity and the cost of the commercial product. In this paper, we demonstrate transient models of supercapacitor energy storage plants operating in coordination with run-of-the-river (ROR), doubly-fed induction generator hydropower plants (HPP) using a system control concept and architecture developed. A detailed transient model of a supercapacitor energy storage device is coupled with the grid via a three-phase inverter/rectifier and bidirectional DC-DC converter. In addition, we use a version of a 14-bus IEEE test case that includes the models of the supercapacitor energy storage device, ROR HPPs, and synchronous condensers that use the rotating synchronous generators of retired coal-powered plants. The purpose of the synchronous condensers is to enhance the system stability by providing voltage and reactive power control, provide power system oscillations damping, and maintain system inertia at secure levels. The control layer provides coordinated, decentralized operation of distributed ROR HPPs and energy storage as aggregate support to power system operations.

25 ENERGY STORAGE↗

Contextualizing context for synthetic biology - identifying causes of failure of synthetic biological systems

Despite the efforts that bioengineers have exerted in designing and constructing biological processes that function according to a predetermined set of rules, their operation remains fundamentally circumstantial. The contextual situation in which molecules and single-celled or multicellular organisms find themselves shapes the way they interact, respond to the environment and process external information. Since the birth of the field, synthetic biologists have had to grapple with contextual issues, particularly when the molecular and genetic devices inexplicably fail to function as designed when tested in vivo. In this review, we set out to identify and classify the sources of the unexpected divergences between design and actual function of synthetic systems and analyze possible methodologies aimed at controlling, if not preventing, unwanted contextual issues.

59 BASIC BIOLOGICAL SCIENCES↗

Elucidating potential-induced degradation in bifacial PERC silicon photovoltaic modules

This paper elucidates the behavior and underlying mechanism of potential-induced degradation (PID) on the rear side of p-type monocrystalline silicon bifacial passivated emitter and rear cell (PERC) photovoltaic modules. At 50 degrees C, 30% relative humidity, and -1000 V bias to the solar cells with aluminium foil on the rear glass surface, the rear-side performance of bifacial PERC modules at standard testing conditions degraded dramatically after 40 hours with a 40.4%, 36.2%, and 7.2% loss in maximum power (Pmpp), short-circuit current (Isc), and open-circuit voltage (Voc), respectively. The front-side standard testing condition performance, on the other hand, showed less degradation; Pmpp, Isc, and Voc dropped by 12.0%, 5.2%, and 5.3%, respectively. However, negligible degradation was observed when the solar cells were positively biased. Based on I-V characteristics, electroluminescence, external quantum efficiency measurements, and the effective minority-carrier lifetime simulation, the efficiency loss is shown to be caused by the surface polarization effect; positive charges are attracted to the passivation/antireflection stack on the rear surface and reduce its field effect passivation performance. Extended PID testing to 100 hours showed an increase in device performances (relative to 40 hours) due to the formation of an inversion layer along the rear surface. In addition, replacing ethylene-vinyl acetate copolymer with polyolefin elastomer films significantly slows down the progression of PID, whereas a glass/transparent backsheet design effectively protects the rear side of bifacial PERC modules from PID. Furthermore, PID on the rear side of bifacial PERC modules is fully recoverable, and light greatly promotes recovery of the observed PID.

14 SOLAR ENERGY↗

Strategies for Minimizing Occupational Radiation Exposure in Cardiac Imaging

Purpose of Review: Radiation safety has been at the center of interest of both researchers and healthcare institutions. This review will summarize and shed light on the various techniques adapted to reduce staff exposure to ionizing radiation (IR) in the field of cardiac imaging. Recent Findings: In the last years, with the advance of awareness and the development of new technologies, there have been several tools and techniques adapted. The breakthrough of several technologies to lower radiation dose and shorten the duration of diagnostic tests associated with IR, the use of protection devices by staff members, and mostly the awareness of exposure to IR are the hallmark of these advances. Using all these measures has led to a significant decrease in staff exposure to IR. Summary: Reducing staff exposure to meet the “As Low As Reasonably Achievable” principle is feasible. This review introduces the most important strategies applied in cardiac imaging.

61 RADIATION PROTECTION AND DOSIMETRY↗

Micro capillary pumped loop system for a cooling high power device

This work discusses the operation of a capillary-driven two-phase loop, configured on a micro capillary pumped loop (MCPL) system without an external power supply but capable of automatic heat transmission. The MCPL device, fabricated using MEMS (microelectricomechanical system) technology, was tested and yielded the following results: first, the proposed design of a new MCPL system with a water reservoir operating at low pressures is feasible and requires no additional power supply and instead relies on automatic heat transmission. Second, the issue of depriming in a MCPL was effectively controlled, the endurance of MCPL for the depriming problem can be executed by yielding input heat fluxes of 185.2 W/cm{sup 2} at an evaporator temperature of 165 C, thus revealing that this model provides excellent cooling performance. Third, the effective operation range was determined and its successful operation was confirmed for MCPL. The ease of starting up increased with the temperature of the reservoir. Finally, two-phase tension that originated in the groove structures in the evaporator and condenser was confirmed to control the movement of the fluids throughout the system and verified to be effective in improving cooling efficiency. (author)

42 ENGINEERING↗

HIDRA-MAT liquid metal droplet injector for liquid metal applications in HIDRA

A liquid metal droplet injector was explicitly designed for the Hybrid Illinois Device for Research and Applications Material Analysis Test-stand (HIDRA-MAT) at the University of Illinois Urbana-Champaign to prepare liquid metal plasma-facing components (PFCs) for plasma exposure. The design goals were to create a compact, reliable, and robust design that could apply liquid metal droplets in-vacuo to a variety of samples. The injector was designed for liquid metal use, and results discussed pertain to lithium. The injector can produce lithium droplets of consistent size by utilizing programmable piston movement. Here, droplet formation data is presented for four different piston step sizes (0.125 mm, 0.25 mm, 0.5 mm, and 1 mm) at three different nozzle temperatures (185 °C, 230 °C, and 270 °C). Droplets are formed on the injector nozzle tip and a linear shift mechanism vertically translates the droplet to the substrate for application. This design prevents the droplet from inadvertently detaching off the nozzle and falling to the sample. Application of the liquid metal droplet ensures placement consistency on the substrate and helps avoid damage to components in HIDRA-MAT that should not interact with liquid metals. A description of the liquid lithium droplet creation and application results is given and provides additional insight into the cooling and oxidation of lithium droplets under vacuum conditions. A second nozzle was fabricated and demonstrated repeatability in droplet diameter creation having a variance of ±0.14 mm for droplets created from the same number of piston steps. The end-use for the injector on HIDRA-MAT is to apply liquid metals to PFCs and expose them to HIDRA's plasma with subsequent intershot in-vacuo surface analysis in HIDRA-MAT for plasma-material interaction studies.

42 ENGINEERING↗

Electrochemical investigation of stainless steel corrosion in a proton exchange membrane electrolyzer cell

The lack of a fundamental understanding of the corrosion mechanisms in the electrochemical environments of proton exchange membrane (PEM) electrolyzer and/or fuel cells (ECs/FCs) has seriously hindered the improvement of performance and efficiency of PEM ECs/FCs. In this study, a stainless steel mesh was purposely used as an anode gas diffusion layer that was intentionally operated with high positive potentials under harsh oxidative environments in a PEMEC to study the corrosion mechanism of metal migration. A significant amount of iron and nickel cations were determined to transport through the anode catalyst layer, the PEM and the cathode catalyst layer during the PEMEC operation. The formation/deposition of iron oxide and nickel oxide on the carbon paper gas diffusion layer at the cathode side is first revealed by both scanning electron microscope and X-ray diffraction. The results indicate the corrosion elements of iron and nickel are transported from anode to cathode through the catalyst-coated membrane, and deposited on carbon fibers as oxides. This phenomenon could also open a new corrosion-based processing approach to potentially fabricate multifunctional oxide structures on carbon fiber devices. This study has demonstrated a new accelerated test method for investigating the corrosion and durability of metallic materials as well.

08 HYDROGEN↗

Superplastic Creep of Metal Nanowires From Rate-Dependent Plasticity Transition

Understanding the time-dependent mechanical behavior of nanomaterials such as nanowires is essential to predict their reliability in nanomechanical devices. This understanding is typically obtained using creep tests, which are the most fundamental loading mechanism by which the time dependent deformation of materials is characterized. However, due to existing challenges facing both experimentalists and theorists, the time dependent mechanical response of nanowires is not well-understood. Here, we use atomistic simulations that can access experimental time scales to examine the creep of single-crystal face-centered cubic metal (Cu, Ag, Pt) nanowires. Here, we report that both Cu and Ag nanowires show significantly increased ductility and superplasticity under low creep stresses, where the superplasticity is driven by a rate-dependent transition in defect nucleation from twinning to trailing partial dislocations at the micro- or millisecond time scale. The transition in the deformation mechanism also governs a corresponding transition in the stress-dependent creep time at the microsecond (Ag) and millisecond (Cu) time scales. Overall, this work demonstrates the necessity of accessing time scales that far exceed those seen in conventional atomistic modeling for accurate insights into the time-dependent mechanical behavior and properties of nanomaterials.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Diagnostics of Fast Electrons within Castor Tokamak by Means of a Modified Cherenkov-Type Probe

The paper reports on experimental studies performed within the CASTOR tokamak, which was operated at IPP in Prague, Czech Republic, during the last experimental campaign carried out in autumn 2006. The main aim was to implement a new diagnostic technique for measurements of energetic (>80 keV) electrons within the tokamak edge plasma region. The technique was based on the use of a Cherenkov-type probe similar to the first prototype detector, which was tested during the previous experiments with the CASTOR device. In particular, the distributions of fast electrons in a standard scenario at different values of plasma current I{sub p}, and toroidal magnetic field B{sub T} are determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact And Robust Laser Impulse Measurement Device, With Ultrashort Pulse Laser Ablation Results

An impulse measurement device and analysis package was conceived, designed, constructed, tested, and demonstrated to be capable of: measuring nanoNewton-seconds to milliNewton-seconds of impulse due to laser-ablation; being transported as carry-on baggage; set-up and tear-down times of less than an hour; target exchange times of less than two minutes (targets can be ablated at multiple positions for thousands of shots); measurements in air and in vacuum; error of just a few percent; repeatability over a wide range of potential systematic error sources; and time between measurements, including ring-down and analysis, of less than 30 seconds. The instrument consists of a cantilever (i.e. leaf spring), whose time-dependent displacement/oscillation is measured and analyzed to determine the impulse imparted by a laser pulse to a target. These shapes are readily/commercially available, and any target material can be used, provided it can be fashioned in the form of a cantilever, or as a coating/film/tape, suitable for mounting on a cantilever of known geometry. The instrument was calibrated both statically and dynamically, and measurements were performed on brass, steel, and Aluminum, using laser pulses of {approx}7 ns, {approx}500 ps, and {approx}500 fs. The results agree well with those published in the literature, with surface effects, atmosphere, and pre-/post-pulses demonstrating interesting effects and indicating areas for further study. These parameters should be carefully controlled and held constant during a series of measurements. The impulse imparted by ablation due to laser filaments in air was also explored.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic and molecular effects on spherically convergent ion flow. II. Multiple molecular species

A theoretical model for the effect of molecular interactions on the flow of molecular ions in spherically convergent geometry where the inner grid (cathode) is at a large negative potential and the outer grid (anode) is grounded has been developed. The model assumes a weakly ionized deuterium plasma composed of D{sup +}, D{sub 2}{sup +}, and D{sub 3}{sup +} ions that interact with the dominant background gas (D{sub 2}). The interactions included are charge exchange, ionization, and dissociative processes. The formalism developed includes the bouncing motion of the ions in the electrostatic well and sums over all generations of subsequent ions produced by atomic and molecular processes. This leads to a set of two coupled Volterra integral equations, which are solved numerically. From the solution of the Volterra equations, one can obtain quantities of interest, such as the energy spectra of the ions and fast neutral atoms and molecules, and the fusion reaction rate. To provide an experimental test, the model is applied to inertial electrostatic devices and the calculated neutron production rate is compared to previously reported measurements for one University of Wisconsin inertial electrostatic confinement device [D. C. Donovan et al., Fusion Sci. Technol. 56, 507 (2009)]. The results show general agreement with the experimental results, but significant differences remain to be resolved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Silicon detectors for monitoring neutron beams in n-TOF beamlines

During 2014, the second experimental area (EAR2) was completed at the n-TOF neutron beam facility at CERN (n-TOF indicates neutron beam measurements by means of time of flight technique). The neutrons are produced via spallation, by means of a high-intensity 20 GeV pulsed proton beam impinging on a thick target. The resulting neutron beam covers the energy range from thermal to several GeV. In this paper, we describe two beam diagnostic devices, both exploiting silicon detectors coupled with neutron converter foils containing {sup 6}Li. The first one is based on four silicon pads and allows monitoring of the neutron beam flux as a function of the neutron energy. The second one, in beam and based on position sensitive silicon detectors, is intended for the reconstruction of the beam profile, again as a function of the neutron energy. Several electronic setups have been explored in order to overcome the issues related to the gamma flash, namely, a huge pulse present at the start of each neutron bunch which may blind the detectors for some time. The two devices were characterized with radioactive sources and also tested at the n-TOF facility at CERN. The wide energy and intensity range they proved capable of sustaining made them attractive and suitable to be used in both EAR1 and EAR2 n-TOF experimental areas, where they became immediately operational.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary consideration of CFETR ITER-like case diagnostic system

Chinese Fusion Engineering Test Reactor (CFETR) is a new superconducting tokamak device being designed in China, which aims at bridging the gap between ITER and DEMO, where DEMO is a tokamak demonstration fusion reactor. Two diagnostic cases, ITER-like case and towards DEMO case, have been considered for CFETR early and later operating phases, respectively. In this paper, some preliminary consideration of ITER-like case will be presented. Based on ITER diagnostic system, three versions of increased complexity and coverage of the ITER-like case diagnostic system have been developed with different goals and functions. Version A aims only machine protection and basic control. Both of version B and version C are mainly for machine protection, basic and advanced control, but version C has an increased level of redundancy necessary for improved measurements capability. The performance of these versions and needed R&D work are outlined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of visible spectroscopy diagnostics for W sources assessment in WEST

The present work concerns the development of a W sources assessment system in the framework of the tungsten-W environment in steady state tokamak project that aims at equipping the existing Tore Supra device with a tungsten divertor in order to test actively cooled tungsten Plasma Facing Components (PFCs) in view of preparing ITER operation. The goal is to assess W sources and D recycling with spectral, spatial, and temporal resolution adapted to the PFCs observed. The originality of the system is that all optical elements are installed in the vacuum vessel and compatible with steady state operation. Our system is optimized to measure radiance as low as 10{sup 16} Ph/(m{sup 2} s sr). A total of 240 optical fibers will be deployed to the detection systems such as the “Filterscope,” developed by Oak Ridge National Laboratory (USA) and consisting of photomultiplier tubes and filters, or imaging spectrometers dedicated to Multiview analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visible spectroscopy diagnostics for tungsten source assessment in the WEST tokamak: First measurements

The present work concerns the measurements obtained with the Tungsten (W) Environment in Steady-state Tokamak (WEST) visible spectroscopy system during the first experimental campaign. This system has been developed in the framework of the WEST project that equipped the existing Tore Supra device with a tungsten divertor in order to test actively cooled tungsten Plasma Facing Components (PFC) in view of preparing for ITER operation. The goal of this diagnostic is to measure the PFC sources and the deuterium recycling with spectral, spatial, and temporal resolution adapted to the predicted power deposition profiles on the objects observed. Three kinds of PFCs are monitored: the Ion Cyclotron Resonance Heating (ICRH) antenna and Low Hybrid Current Drive (LHCD) launcher W limiters; one of the 6 W inner bumpers; and the upper and lower W divertors. Large-aperture in-vessel actively cooled optical systems (f-number ~ 3) were installed for each view and connected to optical fibres. A total of 240 optical fibers can be distributed on various detection systems including a fast response-time, multi-channel, filtered photodetector-based “Filterscope” system, developed by Oak Ridge National Laboratory (USA) as well as grating spectrometers optimized for multi-sightline analysis. The first WEST experimental campaign conducted in 2017 has been dedicated to plasma start-up development during which the visible spectroscopy system has provided crucial information related to the impurity content first and then impurity sources. The diagnostic setup for that first experimental campaign was limited to the inner bumper and outer limiters but was sufficient to demonstrate that the optical setup was in accordance with the specifications. The radiance calibration procedure allowed us to estimate fluxes from the main limiter of about 8 × 10 18 atoms/(s m 2 ) and to show a first W source radial profile along the outboard limiter.

Meyer, O.↗

Intrinsically stretchable electrode array enabled in vivo electrophysiological mapping of atrial fibrillation at cellular resolution

Electrophysiological mapping of chronic atrial fibrillation (AF) at high throughput and high resolution is critical for understanding its underlying mechanism and guiding definitive treatment such as cardiac ablation, but current electrophysiological tools are limited by either low spatial resolution or electromechanical uncoupling of the beating heart. To overcome this limitation, here we introduce a scalable method for fabricating a tissue-like, high-density, fully elastic electrode (elastrode) array capable of achieving real-time, stable, cellular level-resolution electrophysiological mapping in vivo. Testing with acute rabbit and porcine models, the device is proven to have robust and intimate tissue coupling while maintaining its chemical, mechanical, and electrical properties during the cardiac cycle. The elastrode array records epicardial atrial signals with comparable efficacy to currently available endocardial-mapping techniques but with 2 times higher atrial-to-ventricular signal ratio and >100 times higher spatial resolution and can reliably identify electrical local heterogeneity within an area of simultaneously identified rotor-like electrical patterns in a porcine model of chronic AF.

60 APPLIED LIFE SCIENCES↗