Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Independent Orbiter Assessment (IOA): Analysis of the reaction control system, volume 2

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results for the Reaction Control System (RCS). The RCS is situated in three independent modules, one forward in the orbiter nose and one in each OMS/RCS pod. Each RCS module consists of the following subsystems: Helium Pressurization Subsystem; Propellant Storage and Distribution Subsystem; Thruster Subsystem; and Electrical Power Distribution and Control Subsystem. Volume 2 continues the presentation of IOA analysis worksheets.

Burkemper, V. J.↗

Independent Orbiter Assessment (IOA): Analysis of the reaction control system, volume 3

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results for the Reaction Control System (RCS). The RCS is situated in three independent modules, one forward in the orbiter nose and one in each OMS/RCS pod. Each RCS module consists of the following subsystems: Helium Pressurization Subsystem; Propellant Storage and Distribution Subsystem; Thruster Subsystem; and Electrical Power Distribution and Control Subsystem. Volume 3 continues the presentation of IOA analysis worksheets and the potential critical items list.

Burkemper, V. J.↗

Assessing the Impact of Cybersecurity Attacks on Energy Systems

This paper investigates the cyber resiliency of future power systems with high penetration of distributed energy resources using advanced distributed and (or) hierarchical control architectures. Specifically, we simulate cyberattacks on three prototypical use cases, and we identify attack scenarios that are the most damaging to the overall system performance. We show that these attacks can have a significant impact on grid operation. Results provide additional insights into the robustness of the system to the most common cyberattacks.

buildings↗

Grid-Forming Frequency Shaping Control for Low-Inertia Power Systems

As power systems transit to a state of high renewable penetration, little or no presence of synchronous generators makes the prerequisite of well-regulated frequency for grid-following inverters unrealistic. As such, there is a trend to resort to grid-forming inverters which set frequency directly. We propose a novel grid-forming frequency shaping control that is able to shape the aggregate system frequency dynamics into a first-order one with the desired steady-state frequency deviation and Rate of Change of Frequency (RoCoF) after a sudden power imbalance. The no overshoot property resulting from the first-order dynamics allows the system frequency to monotonically move towards its new steady-state without experiencing frequency Nadir, which largely improves frequency security. We prove that our grid-forming frequency-shaping control renders the system internally stable under mild assumptions. The performance of the proposed control is verified via numerical simulations on a modified Icelandic Power Network test case.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Luminosity distributions for Virgo cluster galaxies. I Near-infrared surface photometry of 81 disk systems

I-band (8500 A) surface photometry of 81 galaxies in Virgo provides the basis for comparing the disk properties of S0 galaxies with those of Sa, Sb, and Sc systems. No significant difference is found in the distributions of either central surface brightness or exponential scale length between S0's and later Hubble types. Because the I-band is dominated by contributions from the old-disk population, this result suggests that the factors which control the distribution of luminous disk material in all types of disk systems are identical. Evidently, environmental factors have not played a significant role in affecting the star-forming histories of the Virgo disks.

Boroson, T. A.↗

Ground test experiment for large space structures, appendix I

Marshall Space Flight Center has developed a Large Space Structure (LSS) ground test verification experiment facility having adequate fidelity and flexibility to accommodate the demands of LSS control theory testing. The first experiment is in the subsystem verification and integration phase. This test employs the ASTROMAST, a lightweight S glass composite deployable beam structure, as the test article and is cited to prove out centralized and distributed sensor control strategies.

Tollison, D. K.↗

Harnessing Virtual Power Plants Reliably: Enabling tools for increased observability, controllability, operation, and aggregation of distributed energy resources

Harnessing virtual power plants enhances the integration of distributed energy resources into utility grids for a sustainable energy future. Virtual power plants (VPPs) aggregate DERs to enhance resource adequacy and reduce emissions. U.S. utilities are exploring various technologies to manage DERs effectively. FERC Order 2222 allows DERs to participate in both wholesale and retail markets. Enhancing observability and controllability of behind-the-meter (BTM) DERs is essential for reliable grid operations. A hierarchical control architecture can improve coordination among residential energy resources. Field tests showed nearly 20% energy savings and 30% peak power reduction during grid events. Effective management of DERs requires enhanced situational awareness to prevent grid congestion. Integrating DER management systems (DERMS) with existing planning tools can improve operational security. Near-real-time grid models can validate optimal resource set points against resource uncertainty. Traditional uninterruptible power supplies (UPS) can be upgraded to support grid services and become part of VPPs. Upgrading UPS systems can reduce costs by 75% and unlock significant battery capacity. New battery management systems and grid-aware controllers are essential for optimizing UPS performance. Continued research and development are necessary to address challenges in integrating DERs into utility grids. Encouraging customer participation in pilot programs is vital for the evolution of VPPs. Here, the shift towards price-responsive DERs and VPPs is expected to enhance energy distribution efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The linear quadratic optimal control problem for infinite dimensional systems over an infinite horizon - Survey and examples

Available published results are surveyed for a special class of infinite-dimensional control systems whose evolution is characterized by a semigroup of operators of class C subscript zero. Emphasis is placed on an approach that clarifies the system-theoretic relationship among controllability, stabilizability, stability, and the existence of a solution to an associated operator equation of the Riccati type. Formulation of the optimal control problem is reviewed along with the asymptotic behavior of solutions to a general system of equations and several theorems concerning L2 stability. Examples are briefly discussed which involve second-order parabolic systems, first-order hyperbolic systems, and distributed boundary control.

Bensoussan, A.↗

Control systems and data management for high-power laser facilities

The next generation of high-power lasers enables repetition of experiments at orders of magnitude higher frequency than what was possible using the prior generation. Facilities requiring human intervention between laser repetitions need to adapt in order to keep pace with the new laser technology. A distributed networked control system can enable laboratory-wide automation and feedback control loops. These higher-repetition-rate experiments will create enormous quantities of data. A consistent approach to managing data can increase data accessibility, reduce repetitive data-software development and mitigate poorly organized metadata. An opportunity arises to share knowledge of improvements to control and data infrastructure currently being undertaken. We compare platforms and approaches to state-of-the-art control systems and data management at high-power laser facilities, and we illustrate these topics with case studies from our community

47 OTHER INSTRUMENTATION↗

3D dose and TCP distribution for radionuclide therapy in nuclear medicine

A common feature to any radiant therapy is that lesion and health tissue dosimetry provides relevant information for treatment optimization along with dose-efficacy and dose-complication correlation studies. Nowadays, different radionuclide therapies are commonly available, assessing both systemic and loco-regional approach and using different alfa-, beta-and gamma-emitting isotopes and binding molecules. It is well established, that specific dosimetric approaches become necessary according to each therapy modality. Sometimes, observed activity distribution can be satisfactory represented by simple geometrical models. However, Monte Carlo techniques are capable of better approaches, therefore becoming sometimes the only way to get dosimetric data since the patient-specific situation can not be adequately represented by conventional dosimetry techniques. Therefore, due to strong limitations of traditional and standard methods, this work concentrates on the development of a dedicated and novel calculation system in order to assess the dose distribution within the irradiated patient. However, physical dose may not be enough information in order to establish real deterministic biological/metabolic effects; therefore complementary radiobiological models have been suitably introduced with the aim of performing realistic 3D dose as well as corresponding Tumor Control Probability distribution calculation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Elemental Characterization of Neutron-Irradiated Tungsten Using the GD-OES Technique

In reactor-relevant fusion divertor conditions, tungsten (W) will be used as an armor material due to its excellent thermal properties. It will be exposed to impurities from numerous sources, including ion implantation and mixing, neutron transmutation, low-Z plasma-facing-component (PFC) redeposition and codeposition of deuterium and tritium fuel, and trapped helium bubbles. The impurity plasma material–interaction effects are a concern because they can cause gradual degradation of the material and of plasma performance due to dust formation, fuel retention, and even changes to the thermal and mechanical properties of the W armor. It is crucial to measure the amount of impurities in W, and the glow discharge–optical emission spectroscopy (GD-OES) technique is exceptionally well suited for analysis of irradiated samples. GD-OES can measure a sample’s elemental composition by sputtering the surface of the sample, ionizing the eroded material, and measuring the optical emission of the excited atoms. In order for the GD-OES technique to be applied to neutron-irradiated tungsten samples, a mounting system for miniature samples was designed. The sample mounting and centering procedure was successful in measuring the depth distribution of control W and W alloy sample elemental concentrations. These control depth spectra will be used as elemental references for postirradiated samples. The residence time of surface layers was measured, a comparison of signals from different anodes was completed, and the influence of initial surface roughness or nonuniformity was understood. The depth distribution of an arc-welded W-0.4% rhenium (Re) alloy was measured to have a stable Re signal that was distributed evenly in the W matrix. Here, the methods developed here will allow for quantification of impurities and transmutation amounts in neutron-irradiated W. GD-OES is a powerful tool but requires calibration and careful optimization of the parameters to obtain meaningful results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Online Optimization as a Feedback Controller: Stability and Tracking

This paper develops and analyzes feedback-based online optimization methods to regulate the output of a linear time-invariant (LTI) dynamical system to the optimal solution of a time-varying convex optimization problem. The design of the algorithm is based on continuous-time primal-dual dynamics, properly modified to incorporate feedback from the LTI dynamical system, applied to a proximal augmented Lagrangian function. The resultant closed-loop algorithm tracks the solution of the time-varying optimization problem without requiring knowledge of (time-varying) disturbances in the dynamical system. The analysis leverages integral quadratic constraints to provide linear matrix inequality (LMI) conditions that guarantee global exponential stability and bounded tracking error. Analytical results show that, under a sufficient time-scale separation between the dynamics of the LTI dynamical system and the algorithm, the LMI conditions can be always satisfied. The paper further proposes a modified algorithm that can track an approximate solution trajectory of the constrained optimization problem under less restrictive assumptions. As an illustrative example, the proposed algorithms are showcased for power transmission systems, to compress the time scales between secondary and tertiary control, and allow to simultaneously power re-balancing and tracking of DC optimal power flow points.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Human supervision and microprocessor control of an optical tracking system

Gunners using small calibre anti-aircraft systems have not been able to track high-speed air targets effectively. Substantial improvement in the accuracy of surface fire against attacking aircraft has been realized through the design of a director-type weapon control system. This system concept frees the gunner to exercise a supervisory/monitoring role while the computer takes over continuous target tracking. This change capitalizes on a key consideration of human factors engineering while increasing system accuracy. The advanced system design, which uses distributed microprocessor control, is discussed at the block diagram level and is contrasted with the previous implementation.

Bigley, W. J.↗

Design of an optically controlled Ka-band GaAs MMIC phased-array antenna

Phased array antennas long were investigated to support the agile, multibeam radiating apertures with rapid reconfigurability needs of radar and communications. With the development of the Monolithic Microwave Integrated Circuit (MMIC), phased array antennas having the stated characteristics are becoming realizable. However, at K-band frequencies (20 to 40 GHz) and higher, the problem of controlling the MMICs using conventional techniques either severely limits the array size or becomes insurmountable due to the close spacing of the radiating elements necessary to achieve the desired antenna performance. Investigations were made that indicate using fiber optics as a transmission line for control information for the MMICs provides a potential solution. By adding an optical interface circuit to pre-existing MMIC designs, it is possible to take advantage of the small size, lightweight, mechanical flexibility and RFI/EMI resistant characteristics of fiber optics to distribute MMIC control signals. The architecture, circuit development, testing and integration of optically controlled K-band MMIC phased array antennas are described.

Kunath, Richard R.↗

Design of an optically controlled Ka-band GaAs MMIC phased-array antenna

Phased array antennas long were investigated to support the agile, multibeam radiating apertures with rapid reconfigurability needs of radar and communications. With the development of the Monolithic Microwave Integrated Circuit (MMIC), phased array antennas having the stated characteristics are becoming realizable. However, at K-band frequencies (20 to 40 GHz) and higher, the problem of controlling the MMICs using conventional techniques either severely limits the array size or becomes insurmountable due to the close spacing of the radiating elements necessary to achieve the desired antenna performance. Investigations were made that indicate using fiber optics as a transmission line for control information for the MMICs provides a potential solution. By adding an optical interface circuit to pre-existing MMIC designs, it is possible to take advantage of the small size, lightweight, mechanical flexibility and RFI/EMI resistant characteristics of fiber optics to distribute MMIC control signals. The architecture, circuit development, testing and integration of optically controlled K-band MMIC phased array antennas are described.

Kunath, Richard R.↗

Dynamic frequency control in power networks

Node controllers in power distribution networks in accordance with embodiments of the invention enable dynamic frequency control. One embodiment includes a node controller comprising a network interface a processor; and a memory containing a frequency control application; and a plurality of node operating parameters describing the operating parameters of a node, where the node is selected from a group consisting of at least one generator node in a power distribution network wherein the processor is configured by the frequency control application to calculate a plurality of updated node operating parameters using a distributed process to determine the updated node operating parameter using the node operating parameters, where the distributed process controls network frequency in the power distribution network; and adjust the node operating parameters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchical Transactive Control of Flexible Building Loads Under Distribution LMP

With grid modernization efforts, future distribution networks, which consist of various distributed generators and flexible loads, will be more flexible and active. All new network components of distributed energy resources (DERs) drive and enable the transition towards a market-based distribution net-work that seeks the optimal allocation of all DERs. To address challenges associated with DERs, one promising solution is to utilize demand-side flexibility of building loads facilitated by demand response (DR) programs and provide ancillary grid services through distribution-level markets. Under this new paradigm, this paper proposes an efficient DR management strategy incorporating emerging price signals of distribution markets, i.e., distribution locational marginal price (DLMP), based on a hierarchical transactive control approach. The proposed approach establishes a two-layer decision-making framework; the upper layer formulates a bilevel model to obtain an optimal demand response (ODR) under DLMP, and the lower layer employs model-free control to dispatch the (aggregated) ODR to individual end users. Numerical case studies using a modified IEEE 33 test network are performed to verify the effectiveness of the proposed approach; load shifting and peak shaving for the distribution system operator and payments’ reduction for end users while maintaining their comfort.

Park, Byungkwon↗

Access control and privacy in large distributed systems

Large scale distributed systems consists of workstations, mainframe computers, supercomputers and other types of servers, all connected by a computer network. These systems are being used in a variety of applications including the support of collaborative scientific research. In such an environment, issues of access control and privacy arise. Access control is required for several reasons, including the protection of sensitive resources and cost control. Privacy is also required for similar reasons, including the protection of a researcher's proprietary results. A possible architecture for integrating available computer and communications security technologies into a system that meet these requirements is described. This architecture is meant as a starting point for discussion, rather that the final answer.

Leiner, B. M.↗