Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron probe data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Overcoming Oxidation State-Dependent Spectral Interferences: Online Monitoring of U(VI) Reduction to U(IV) via Raman and UV–vis Spectroscopy

Analytical characterization of chemical processes is an essential component of both industrial processes and fundamental studies. Applicable techniques abound, but optical spectroscopy has the unique combination of being easily incorporated into on-line (in-situ) monitoring probes and can also provide abundant chemical information (concentration, oxidation state, speciation). However, this abundance of chemical information can make applying optical spectroscopy to complex chemical processes challenging. This is particularly evident in the bulk electrolysis of U(VI) to U(IV), an essential preparatory step in some nuclear fuel recycling schemes. Starting and product materials have interfering spectral signatures in both electronic and vibrational spectroscopies, making accurate and real-time analysis difficult to achieve. In this paper, we discuss the application of optical spectroscopy to the on-line monitoring of a bulk electrolysis process and the methods utilized to analyze data as well as characterize the efficiency and mechanism of U(IV) generation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of Energetic Electron Fluxes Measured by GPS and THEMIS Spacecraft in the Inner Magnetosphere

Key elements of space weather models are energetic electron fluxes in the inner magnetosphere and the outer radiation belt. Flux depletion is driven by various loss processes: scattering into atmosphere, magnetopause shadowing. Flux enhancement is driven by various acceleration processes: local wave-particle interactions, radial transport, plasma sheet injections. Many of these processes operate on ~ hour timescales. Such mesoscale flux variations are not well traced by equatorial spacecraft with much longer orbits. Energetic electron detectors onboard the Global Positioning System (GPS) constellation provide a unique opportunity for probing such ~ hour-scale flux variations. Measurements from up to 23 identically instrumented GPS satellites cover a wide energy and L-shell range with a subhour time resolution. However, their orbits are inclined and thus all measurements at L-shell >4.3 are off-equatorial. Here, in this report, we present a comparison of equatorial THEMIS and nonequatorial GPS measurements of omnidirectional ≤600 keV electron fluxes. Such a comparison allows us to derive coefficients for using off-equatorial GPS fluxes to infer the equatorial values. These coefficients depend on particle energy and L-shell. We demonstrate a new data set derived from GPS measurements and discuss how it can be used to investigate mesoscale dynamics of energetic electron fluxes in the inner magnetosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

Charged particle diagnostics for inertial confinement fusion and high-energy-density physics experiments

MeV-range ions generated in inertial confinement fusion (ICF) and high-energy-density physics experiments carry a wealth of information, including fusion reaction yield, rate, and spatial emission profile; implosion areal density; electron temperature and mix; and electric and magnetic fields. Here, the principles of how this information is obtained from data and the charged particle diagnostic suite currently available at the major US ICF facilities for making the measurements are reviewed. Time-integrating instruments using image plate, radiochromic film, and/or CR-39 detectors in different configurations for ion counting, spectroscopy, or emission profile measurements are described, along with time-resolving detectors using chemical vapor deposited diamonds coupled to oscilloscopes or scintillators coupled to streak cameras for measuring the timing of ion emission. A brief description of charged-particle radiography setups for probing subject plasma experiments is also given. The goal of the paper is to provide the reader with a broad overview of available capabilities, with reference to resources where more detailed information can be found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CONSTRAINTS ON PERTURBATIONS TO THE RECOMBINATION HISTORY FROM MEASUREMENTS OF THE COSMIC MICROWAVE BACKGROUND DAMPING TAIL

The primordial cosmic microwave background at small angular scales is sensitive to the ionization and expansion history of the universe around the time of recombination. This dependence has been exploited to constrain the helium abundance and the effective number of relativistic species. Here we focus on allowed ionization fraction trajectories, x {sub e}(z), by constraining low-order principal components of perturbations to the standard recombination scenario (x {sub e}-eigenmodes) in the circa 2011 South Pole Telescope (SPT), Atacama Cosmology Telescope (ACT), and Wilkinson Microwave Anisotropy Probe seven-year data (WMAP7). Although the trajectories are statistically consistent with the standard recombination, we find that there is a tension similar to that found by varying the helium fraction. As this paper was in press, final SPT and ACT datasets were released and we applied our framework to them: we find that the tension continues, with slightly higher significance, in the new 2012 SPT data, but find no tension with the standard model of recombination in the new 2012 ACT data. We find that the prior probabilities on the eigenamplitudes are substantially influenced by the requirement that x {sub e}-trajectories conserve electron number. We propose requiring a sufficient entropy decrease between posterior and prior marginalized distributions be used as an x {sub e}-mode selection criterion. We find that in the case of the 2011 SPT/ACT+WMAP7 data only two modes are constrainable, but upcoming ACTPol, Planck, and SPTPol data will be able to test more modes and more precisely address the current tension.

79 ASTRONOMY AND ASTROPHYSICS↗

Laminarin stimulates single cell rates of sulfate reduction whereas oxygen inhibits transcriptomic activity in coastal marine sediment

Abstract The chemical cycles carried out by bacteria and archaea living in coastal sediments are vital aspects of benthic ecology. These ecosystems are subject to physical disruption, which may allow for increased respiration and complex carbon consumption—impacting chemical cycling in this environment often thought to be a terminal place of deposition. We use the redox-enzyme sensitive probe RedoxSensor Green to measure rates of electron transfer physiology in individual sulfate reducer cells residing in anoxic sediment, subjected to transient exposure of oxygen and laminarin. We use index fluorescence activated cell sorting and single cell genomics sequencing to link those measurements to genomes of respiring cells. We measure per-cell sulfate reduction rates in marine sediments (0.01–4.7 fmol SO42− cell−1 h−1) and determine that cells within the Chloroflexota phylum are the most active in respiration. Chloroflexota respiration activity is also stimulated with the addition of laminarin, even in marine sediments already rich in organic matter. Evaluating metatranscriptomic data alongside this respiration-based technique, Chloroflexota genomes encode laminarinases indicating a likely ability to degrade laminarin. We also provide evidence that abundant Patescibacteria cells do not use electron transport pathways for energy, and instead likely carry out fermentation of polysaccharides. There is a decoupling of respiration-related activity rates from transcription, as respiration rates increase while transcription decreases with oxygen exposure. Overall, we reveal an active community of respiring Chloroflexota that cycles sulfate at potential rates of 23–40 nmol h−1 per cm3 sediment in incubation settings, and non-respiratory Patescibacteria that can cycle complex polysaccharides.

Lindsay, Melody R.↗

Recovering the phase and amplitude of X-ray FEL pulses using neural networks and differentiable models

Dynamics experiments are an important use-case for X-ray free-electron lasers (XFELs), but time-domain measurements of the X-ray pulses themselves remain a challenge. Shot-by-shot X-ray diagnostics could enable a new class of simpler and potentially higher-resolution pump-probe experiments. Here, we report training neural networks to combine low-resolution measurements in both the time and frequency domains to recover X-ray pulses at high-resolution. Critically, we also recover the phase, opening the door to coherent-control experiments with XFELs. The model-based generative neural-network architecture can be trained directly on unlabeled experimental data and is fast enough for real-time analysis on the new generation of MHz XFELs.

42 ENGINEERING↗

Protocols for x-ray transient grating pump/optical probe experiments at x-ray free electron lasers

Abstract Transient grating spectroscopy is a specialized application of the four-wave-mixing methodology and constitutes a versatile technique for investigating the dynamics of vibrational, magnetic and electronic degrees of freedom of matter in a background-free fashion. Recent developments in free-electron laser sources have enabled the extension of this technique into the extreme ultraviolet range. Ongoing efforts to expand transient grating spectroscopy into the x-ray regime promise numerous advantages: (1) substantial penetration depths that allow for probing bulk material properties, (2) element specificity via specific core-excited states, and (3) short wavelengths that allow for excitation gratings with higher momentum transfer and improved spatial resolution. In this study, we comprehensively outline the procedures for conducting x-ray transient grating pump/optical probe experiment. The process encompasses the design and alignment of the experimental setup, as well as the subsequent steps involved in data acquisition and analysis. This paper is intended as a comprehensive guide for researchers interested in implementing x-ray transient grating spectroscopy, providing valuable insights into the intricacies of the experimental workflow required for this novel technique. Furthermore, we discuss the potential for extending this methodology to an x-ray pump/x-ray probe scheme, envisioning a future direction that holds promise for enhancing the capabilities and scope of x-ray transient grating spectroscopy, opening new opportunities for studying ultrafast processes with unprecedented temporal and spatial resolutions.

Optics↗

Al-26, Pu-244, Ti-50, REE, and trace element abundances in hibonite grains from CM and CV meteorites

Hibonites from the CM meteorites Murchison, Murray, and Cold Bokkeveld, and hibonites and Ti-rich pyroxene from the CV chondrite Allende are studied. Electron microprobe measurements of major element concentrations and track and ion probe measurements of Mg and Ti isotopic ratios, rare earth elements (REEs), and trace element abundances are analyzed. Correlations between isotopic anomalies in Ti, Al-26, Pu-244, and Mg-26(asterisk) are examined. Ti isotopic anomalies are compared with REE and trace element abundance patterns. Reasons for the lack of Al-26 in the hibonites are investigated and discussed. It is observed that there is no correlation between the Ti isotopic compositions, and the presence of Mg-26(asterisk), Pu-244, and REE and trace element patterns in individual hibonite samples. The data reveal that hibonites are not interstellar dust grains but formed on a short time scale and in localized regions of the early solar system.

Fahey, A. J.↗

SISGR: Atom chip microscopy: A novel probe for strongly correlated materials

Microscopy techniques co-opted from nonlinear optics and high energy physics have complemented solid-state probes in elucidating the order manifest in condensed matter materials. Up until now, however, no attempts have been made to use modern techniques of ultracold atomic physics to directly explore properties of strongly correlated or topologically protected materials. Our current program is focused on introducing a novel magnetic field microscopy technique into the toolbox of imaging probes. Our prior DOE ESPM program funded the development of a novel instrument using a dilute gas Bose-Einstein condensate (BEC) as a scanning probe capable of measuring tiny magnetic (and electric) DC and AC fields above materials. We successfully built the world's first “scanning cryogenic atom chip microscope”, and we now are in the process of characterizing its performance before using the instrument to take the first wide-area images of transport flow within unconventional superconductors, pnictides and oxide interfaces (LAO/STO), topological insulators, and colossal magnetoresistive manganites. We will do so at temperatures outside the capability of scanning SQUIDs, with ~10x better resolution and without 1/f-noise. A notable goal will be to measure the surface-to-bulk conductivity ratio in topological insulators in a relatively model-independent fashion. We have completed the construction of this magnetic microscope. The instrument uses atom chips—substrates supporting micron-sized current-carrying wires that create magnetic microtraps near surfaces for ultracold thermal gases and BECs—to enable single-shot and raster-scanned large-field-of-view detection of magnetic fields. The fields emanating from electronic transport may be detected at the 10 -7 flux quantum (Φ0) level and below; that is, few to sub-micron resolution of sub-nanotesla fields over single-shot, millimeter-long detection lengths. By harnessing the extreme sensitivity of atomic clocks and BECs to external perturbations, we are now in a position to use atom chips for imaging transport in new regimes. Scanning quantum gas atom chip microscopy introduces three very important features to the toolbox of high-resolution scanning microscopy of strongly correlated or topological materials: simultaneous detection of magnetic and electric fields (down to the sub-single electron charge level; no invasive large magnetic fields or gradients; simultaneous micro- and macroscopic spatial resolution; DC to MHz detection bandwidth; freedom from 1/ƒ flicker noise at low frequencies; and, perhaps most importantly, the complete decoupling of probe and sample temperatures. The atom chip microscope can operate at maximum sensitivity and resolution without regard to the substrate temperature. While the BEC is among the coldest objects realizable (100 nK temperatures are typical), the atom chip substrate can be positioned 1 μm away from the BEC and be as hot as 400 K or as cold as the cryostat can cool. This is because unlike superconducting probes, whose temperature is closely coupled to nearby materials, quantum gases are immune to radiative heating. The energy gap between a Rb atom’s ground state and first excited state far exceeds the typical energy of room-temperature blackbody radiation; such atoms are therefore transparent to radiation heating by materials at room temperature or below. We experimentally demonstrated a new atom chip trapping system that allows the placement and high-resolution imaging of ultracold atoms within microns from any ≤100 μm-thin, UHV-compatible material, while also allowing sample exchange with minimal experimental downtime. The sample is not connected to the atom chip, allowing rapid exchange without perturbing the atom chip or laser cooling apparatus. Exchange of the sample and retrapping of atoms has been performed within a week turnaround, limited only by chamber baking. Moreover, the decoupling of sample and atom chip provides the ability to independently tune the sample temperature and its position with respect to the trapped ultracold gas, which itself may remain in the focus of a high-resolution imaging system. We confine 100-nK BECs of 104 87Rb atoms near a gold-mirrored 100-μm-thick silicon substrate. The substrate can be cooled to 35 K without use of a heat shield, while the atom chip, 120-μm away, remains at room temperature. Atoms may be imaged with 1-μm resolution and retrapped every 16 s, allowing rapid data collection. Straightforward improvements will allow us to push sample temperatures close to 4 K, and improve imaging resolution from 1 μm down to a few-100 nm, thereby providing 10 -9 Φ0 detection sensitivity. We will test the utility of this technique by imaging the magnetic fields emanating from electronic transport and domain percolation in several interesting examples of strongly correlated or topologically protected materials. STM, transport, and x-ray scattering experiments have, among others, revealed the existence of a quantum liquid crystal state in iron (pnictide) and cuprate superconductors. This strongly correlated state of matter could also be detected by imaging the fluctuating transport (spatially and in time) of electrons as the phase/regime boundary is crossed between the pnictide non-Fermi liquid (cuprate strange metal) and the pnictide magnetic phase (cuprate pseudogap regime). Our ability to image wide-area inhomogeneous current flow from room-temperature to <10 K will allow us to study the developing domain structure and transport near twin boundary interfaces through the T N ≈50–150 K nematic transition recently identified in bulk transport experiments by Ian Fisher's group in underdoped Fe-arsinide superconductors. Again, this highlights a main feature of our cryogenic atom chip microscope: the ability to image transport regardless of the sample temperature since the BEC, at nK temperatures, is transparent to blackbody radiation, even when held a microns from the surface.

36 MATERIALS SCIENCE↗

Probing Ganymede's Magnetosphere with Field Line Resonances

We report on the spectrum of field line resonances identified in data acquired by the Galileo spacecraft within Ganymede's magnetosphere on a relatively low latitude pass. We infer properties of the plasma distribution and its transport from the observed spectrum. The harmonic structure in the spectrum of the magnetometer data agrees very well with the frequencies predicted for resonances of a dipole field. The spectrum implies a density of 2 amu per cubic centimeter near the equator on closed field lines of Ganymede's magnetic field inside of 2 RG (Ganymede radii). This density is significantly reduced relative to the local density of the Jovian plasma sheet near Ganymede (less than or equal to 8 electrons per cubic centimeter, or approximately equal to 100 amu per cubic centimeter for an average ion mass per charge of 20 amu and average charge of 1.5 electron charges). A shadowing effect of Ganymede for the flow of particles injected at a reconnection layer on the side of the moon downstream relative to the direction of torus plasma flow accounts for the marked density depletion. Implications for conducting paths near Ganymede's surface are considered.

Volwerk, M.↗

Chloride Reduction of Mn 3+ in Mild Hydrothermal Synthesis of a Charge Ordered Defect Pyrochlore, CsMn 2+ Mn 3+ F 6 , a Canted Antiferromagnet with a Hard Ferromagnetic Component

Geometrically frustrated systems play an important role in studying new physical phenomena and unconventional thermodynamics. Charge ordered defect pyrochlores AM 2+ M 3+ F 6 offer a convenient platform for probing the interplay between electron distribution over M 2+ and M 3+ sites and structural distortions; however, they are limited to compounds with M 2+/3+ = V, Fe, Ni, and Cu due to difficulties in the simultaneous stabilization of other 3d elements in the +2 and +3 oxidation states. Herein, we employ Cl– anions under hydrothermal conditions for the mild reduction of Mn 2 O 3 in concentrated HF to obtain the CsMn 2+ Mn 3+ F 6 composition as a phase pure sample and study its properties. The magnetism of CsMn 2 F 6 was characterized by measuring the magnetic susceptibility and isothermal magnetization data, and a magnetic transition to a canted antiferromagnet state was found at 24.1 K. We determined the magnetic structure of CsMn 2 F 6 using powder neutron diffraction, which revealed successive long-range ordering of the Mn 2+ and Mn 3+ sites that is accompanied by a second transition. As a result, the role and strength of magnetic exchange interactions were characterized using DFT calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tunable thermodynamics and kinetics for hydrogen storage : nanoparticle synthesis using ordered polymertemplates.

Theory and experiment suggest nanoscale hydride particles are destabilized relative to bulk, but the origin of this effect is unclear. Both size and local environment may play a role. The overall project objective is to achieve tunable thermodynamics for hydrogen storage materials by controlling nanoparticle size, composition, and environment. Key Goals for FY09 are: (1) Demonstrate and downselect infiltration methods; (2) Measure desorption kinetics for MgH{sub 2} and NaAlH{sub 4} nanoparticles and LiBH{sub 4} thin films; (3) Benchmark DFT and atomistic nanoparticle models using Quantum Monte Carlo (QMC); and (4) Quantify effect of nanoparticle size on {Delta}H{sub d}{sup o} using MgH{sub 2} as initial example. Summary of the key results are: (1) New highly ordered nanoporous templates enable systematic probing of nanoscale effects - Nanoscale NaAlH{sub 4} particles (as small as 1.5 nm diameter) exhibit improved H{sub 2} desorption kinetics relative to bulk and Preliminary data suggest MgH{sub 2} nanoparticle formation and possibly improved desorption kinetics; (2) Benchmarking DFT against QMC reveals significant errors that are non-systematic (H{sub 2} desorption energies underpredicted by as much as 30 kJ/mol); (3) QMC predicts greatest effect of size is for extremely small particles; e.g. (MgH{sub 2}){sub n}, n {le} 6 which is much smaller than predicted by Wolfe construction approach and observed in experiments and it suggests factors other than electronic structure (e.g. surrounding chemical environment) influence stability; (4) New NanoPEGS code developed and tested for MgH{sub 2} 2particles; and (5) New mass spec tool (STMBMS) reveals key details of hydrogen desorption process.

08 HYDROGEN↗

Insulator Surface Flashover Due to UV Illumination

The surface of an insulator under vacuum and under electrical charge will flashover when illuminated by a critical dose of ultra-violet (UV) radiation - depending on the insulator size and material, insulator cone angle, the applied voltage and insulator shot-history. A testbed comprised of an excimer laser (KrF, 248 nm, {approx}16 MW, 30 ns FWHM,), a vacuum chamber, and a negative polarity dc high voltage power supply ({le} -60 kV) were assembled to test 1.0 cm thick angled insulators for surface-flashover. Several candidate insulator materials, e.g. High Density Polyethylene (HDPE), Rexolite{reg_sign} 1400, Macor{trademark} and Mycalex, of varying cone angles were tested against UV illumination. Commercial energy meters were used to measure the UV fluence of the pulsed laser beam. In-house designed and fabricated capacitive probes (D-dots, >12 GHz bandwidth) were embedded in the anode electrode underneath the insulator to determine the time of UV arrival and time of flashover. Of the tested insulators, the +45 degree Rexolite insulator showed more resistance to UV for surface flashover; at UV fluence level of less than 13 mJ/cm{sup 2}, it was not possible to induce a flashover for up to -60 kV of DC potential across the insulator's surface. The probes also permitted the electrical charge on the insulator before and after flashover to be inferred. Photon to electron conversion efficiency for the surface of Rexolite insulator was determined from charge-balance equation. In order to understand the physical mechanism leading to flashover, we further experimented with the +45 degree Rexolite insulator by masking portions of the UV beam to illuminate only a section of the insulator surface; (1) the half nearest the cathode and subsequently, (2) the half nearest the anode. The critical UV fluence and time to flashover were measured and the results in each case were then compared with the base case of full-beam illumination. It was discovered that the time for the insulator to flash was earlier in time for the cathode-half beam illumination case than the anode-half illumination case which led us to believe that the flashover mechanism for the UV illumination is initiated from the cathode side of the insulator. Qualitatively stated, the testing revealed that the shielding of the cathode triple point against UV is more important than the anode triple junction in the design of vacuum insulators and electrodes. The goal of this work was to acquire empirical data on critical UV fluence (energy per unit area) required to induce surface flashover of vacuum insulators for some candid insulator materials: High Density Polyethylene (HDPE), Rexolite{reg_sign} 1400, Macor{trademark} and Mycalex. This work was a clarification and extension of studies performed by C.L. Enloe, et. al. in the 80's [1-3]. Additionally, to gain an understanding of the physical mechanism of flashover, we experimented with UV illumination of a portion of the insulator's surface near the cathode and subsequently near the anode. The results of these experiments are covered in detail.

36 MATERIALS SCIENCE↗

Curium(iii) radiation-induced reaction kinetics in aqueous media

Insight into the effects of radiolytic processes on the actinides is critical for advancing our understanding of their solution chemistry because the behaviour of these elements cannot be easily separated from the influence of their inherent radiation field. However, minimal information exists on the radiation-induced redox behaviour of curium (Cm), a key trivalent transuranic element present in used nuclear fuel and frequently used as an alpha radiation source. Here we present a kinetic study on the aqueous redox reactions of Cm(III) with radicals generated through the radiolysis of aqueous media. In particular, we probe reaction kinetics in nitric acid solutions that are used as the aqueous phase component of used nuclear fuel reprocessing solvent systems. Second-order rate coefficients (k) were measured for the reaction of Cm(III) with the hydrated electron (e aq - , k = (1.25 ± 0.03) × 10 10 M -1 s -1 ), hydrogen atom (H˙, k = (5.16 ± 0.37) × 10 8 M -1 s -1 ), hydroxyl radical (˙OH, k = (1.69 ± 0.24) × 10 9 M -1 s -1 ), and nitrate radical (NO 3 ˙, k = (4.83 ± 0.09) × 10 7 M -1 s -1 ). Furthermore, the first-ever Cm(II) absorption spectrum (300–700 nm) is also reported. These kinetic data dispel the status quo notion of Cm(III) possessing little to no redox chemistry in aqueous solution, and suggest that the resulting Cm(II) and Cm(IV) transients could exist in irradiated aqueous solutions and be available to undergo subsequent redox chemistry with other solutes.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Hyperfine Interaction and Shockley–Read–Hall Recombination in Semiconductors

Experimental and theoretical studies on optical orientation and spin-dependent recombination in a semiconductor in a magnetic field under the normal incidence of circularly polarized radiation onto the sample surface are reviewed. The experiments were carried out on GaAs{sub 1 –x}N{sub x} solid solutions, in which Ga{sup 2+} interstitial displacement defects play the role of deep paramagnetic centers responsible for spin-dependent recombination. It is established that, in the investigated materials, the hyperfine interaction of a localized electron with one nucleus of the paramagnetic center remains strong even at room temperature. The theory is compared with an experiment conducted in the steady-state excitation mode and under two-pulse pump-probe conditions. An analytical formula for spin beats in a magnetic field is derived.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV Detector

We present constraints on low mass dark matter-electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of $6.1\,\mathrm{g\cdot days}$ of exposure produces exclusion limits for dark matter-electron scattering cross-sections for masses as low as $1\,\mathrm{MeV}/c^2$, as well as on the photon-dark photon mixing parameter and the coupling constant between axion-like particles and electrons for particles with masses $>1.2\,\mathrm{eV}/c^2$ probed via absorption processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development and preliminary results of 270 GHz microwave forward scattering diagnostic system on the experimental advanced superconducting tokamak (EAST)

To measure localized (intermediate, high) poloidal wavenumber electron density fluctuations, a tangential millimeter-wave collective scattering system has been designed and successfully developed on the experimental advanced superconducting tokamak (EAST). This innovative system employs a 270 GHz mm-wave probe beam, emitted from the mid-plane of Port K and directed towards Port P after passing through a combination of two in-vessel mirrors. Here these two ports are located on the EAST device’s midplane and are 110° apart. The downward scattered signals pass through two in-vessel mirrors, and exit through the P window. The received multi-channel separated scattering signals are arranged along the poloidal direction. This optical arrangement makes the monitored turbulent wave number is poloidal dominant and up to 40 cm −1 . The tangential microwave scattering scheme enables this diagnostic to monitor local density fluctuations, with typically a radial spatial resolution △ R = 5 cm, and a wavenumber resolution of △ k = 0.4 cm −1 . The scattering system underwent comprehensive laboratory testing in 2023, with installation finalized in 2024. The system features steerable launch and receiver optics, allowing remote control to position the scattering volume from normalized radius ρ –0 to the pedestal region on a shot-by-shot basis. Effective experimental data, characterized by distinct off-center spectral peaks, have been successfully obtained in neutral beam-heated plasmas on EAST. The beam tracing forward modeling has been employed for experimental data interpretation. The advanced millimeter-wave scattering system provides fluctuation measurement capability from ion temperature gradient to electron temperature gradient scale on low field side. Preliminary experimental density fluctuation data have been successfully obtained in neutral beam-heated plasmas on EAST. The localized measurement will be used for kinetic turbulence transport numerical simulation validation.

high-k collective scattering↗

Scatter broadening of pulsars and implications on the interstellar medium turbulence

Observations reveal a uniform Kolmogorov turbulence throughout the diffuse ionized interstellar medium (ISM) and supersonic turbulence preferentially located in the Galactic plane. Correspondingly, we consider the Galactic distribution of electron density fluctuations consisting of not only a Kolmogorov density spectrum but also a short-wave-dominated density spectrum with the density structure formed at small scales due to shocks. The resulting dependence of the scatter broadening time on the dispersion measure (DM) naturally interprets the existing observational data for both low- and high-DM pulsars. According to the criteria that we derive for a quantitative determination of scattering regimes over wide ranges of DMs and frequencies ν, we find that the pulsars with low DMs are primarily scattered by the Kolmogorov turbulence, while those at low Galactic latitudes with high DMs undergo more enhanced scattering dominated by the supersonic turbulence, where the corresponding density spectrum has a spectral index of ≈2.6. Furthermore, by considering a volume filling factor of the density structures with the dependence on ν as ∝ν{sup 1.4} in the supersonic turbulence, our model can also explain the observed shallower ν scaling of the scattering time than the Kolmogorov scaling for the pulsars with relatively large DMs. The comparison between our analytical results and the scattering measurements of pulsars in turn makes a useful probe of the properties of the large-scale ISM turbulence, e.g., an injection scale of ∼100 pc, and also characteristics of small-scale density structures.

79 ASTRONOMY AND ASTROPHYSICS↗