Search NASA⌕ Search

SEARCH · Search NASA

Results for “error reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Evaluation of piezoceramic actuators for control of aircraft interior noise

Results of an experiment to evaluate piezoceramic actuators as the control actuator for active control of interior noise in a large-scale fuselage model are presented. Control was demonstrated for tonal excitation using a time domain least mean squares algorithm. A maximum of four actuator channels and six error signals were used. The actuators were employed for control of noise at frequencies where interior cavity modes were the dominant response and for driven acoustic responses where a structure resonance was dominant. Global reductions of 9 to 12 dB were obtained for the cases examined. The most effective configuration of skin-mounted actuators was found to be a pure in-plane forcing function as opposed to a bending excitation. The frame-mounted actuators were found to be equally effective as the skin-mounted actuators. However, both configurations resulted in local regions of unacceptably high vibration response in the structure.

Silcox, Richard J.↗

SNPP VIIRS Reflective Solar Bands On-Orbit Calibration Using the Moon

The Visible Infrared Imaging Radiometer Suite (VIIRS) on board the Suomi National Polar-Orbiting Partnership (SNPP) satellite has been on orbit for more than eight years since its launch on October 28, 2011. The VIIRS has 22 spectral bands, among which 14 are reflective solar bands(RSBs) covering a spectral range from 0.41 to 2.25 m. The VIIRS RSBs are primarily calibrated on-orbit by an onboard solar diffuser (SD) panel and a solar diffuser stability monitor (SDSM). Besides the SD and SDSM calibration, the RSBs are scheduled to view the Moon approximately monthly through the instrument’s space view (SV). The lunar observations have also been used to calibrate the RSBs on-orbit since early mission. Due to the non uniformity of the SD’s degradation, the calibration coefficients that are derived from the SD/SDSM calibration have long-term biases, especially at short wavelengths. In addition, the SDSM has no capability to monitor the SD degradation beyond 0.935 m, resulting in long-term bias in the shortwave infrared bands, about 0.72% for band M8 (1.238 m). These biases induce significant errors and long-term drifts in the VIIRS sensor data records (SDR) and consequently in the environmental data records (EDR). Unlike the SD, the Moon is a known stable target and any temporal drifts observed while viewing the Moon can be attributed to the sensor’s degradation. Thus, the VIIRS lunar calibration is used to track the RSB on-orbit changes, especially to provide an accurate long-term baseline. Due to the non-uniformity of the lunar surface, the lunar irradiance, instead of the lunar radiance, is used to calibrate the RSBs. The lunar irradiance strongly depends on lunar view geometry and it is still a challenge to accurately characterize the geometric effects associated with the lunar measurements and any residual errors can induce seasonal oscillations in the derived calibration coefficients. The errors of the geometric dependence correction induce seasonal oscillations in the derived RSB lunar calibration coefficients. In this paper, the algorithms for the view geometric effect correction are significantly improved, resulting in a significant reduction in the seasonal oscillations observed in the calibration coefficient time-series. The lunar and SD/SDSM calibration results are properly incorporated to generate a set of hybrid calibration coefficients and implementation of these coefficients is shown to significantly improve the long-term stability of the VIIRS SDR. This is of fundamental importance in making accurate Earth observations from which reliable and high quality science products are generated. The consequent improvements in SNPP VIIRS RSB SDRs and EDRs are shown and discussed. The lunar calibration methodology can be directly applied to follow-on VIIRS instruments.

Junqiang Sun↗

Neural Network Machine Learning and Dimension Reduction for Data Visualization

Neural network machine learning in computer science is a continuously developing field of study. Although neural network models have been developed which can accurately predict a numeric value or nominal classification, a general purpose method for constructing neural network architecture has yet to be developed. Computer scientists are often forced to rely on a trial-and-error process of developing and improving accurate neural network models. In many cases, models are constructed from a large number of input parameters. Understanding which input parameters have the greatest impact on the prediction of the model is often difficult to surmise, especially when the number of input variables is very high. This challenge is often labeled the "curse of dimensionality" in scientific fields. However, techniques exist for reducing the dimensionality of problems to just two dimensions. Once a problem's dimensions have been mapped to two dimensions, it can be easily plotted and understood by humans. The ability to visualize a multi-dimensional dataset can provide a means of identifying which input variables have the highest effect on determining a nominal or numeric output. Identifying these variables can provide a better means of training neural network models; models can be more easily and quickly trained using only input variables which appear to affect the outcome variable. The purpose of this project is to explore varying means of training neural networks and to utilize dimensional reduction for visualizing and understanding complex datasets.

Liles, Charles A.↗

First Clinical Release of an Online, Adaptive, Aperture-Based Image-Guided Radiotherapy Strategy in Intensity-Modulated Radiotherapy to Correct for Inter- and Intrafractional Rotations of the Prostate

Purpose: We developed and evaluated a correction strategy for prostate rotations using direct adaptation of segments in intensity-modulated radiotherapy (IMRT). Method and Materials: Implanted fiducials (four gold markers) were used to determine interfractional translations, rotations, and dilations of the prostate. We used hybrid imaging: The markers were automatically detected in two pretreatment planar X-ray projections; their actual position in three-dimensional space was reconstructed from these images at first. The structure set comprising prostate, seminal vesicles, and adjacent rectum wall was transformed accordingly in 6 degrees of freedom. Shapes of IMRT segments were geometrically adapted in a class solution forward-planning approach, derived within seconds on-site and treated immediately. Intrafractional movements were followed in MV electronic portal images captured on the fly. Results: In 31 of 39 patients, for 833 of 1013 fractions (supine, flat couch, knee support, comfortably full bladder, empty rectum, no intraprostatic marker migrations >2 mm of more than one marker), the online aperture adaptation allowed safe reduction of margins clinical target volume-planning target volume (prostate) down to 5 mm when only interfractional corrections were applied: Dominant L-R rotations were found to be 5.3 Degree-Sign (mean of means), standard deviation of means {+-}4.9 Degree-Sign , maximum at 30.7 Degree-Sign . Three-dimensional vector translations relative to skin markings were 9.3 {+-} 4.4 mm (maximum, 23.6 mm). Intrafractional movements in 7.7 {+-} 1.5 min (maximum, 15.1 min) between kV imaging and last beam's electronic portal images showed further L-R rotations of 2.5 Degree-Sign {+-} 2.3 Degree-Sign (maximum, 26.9 Degree-Sign ), and three-dimensional vector translations of 3.0 {+-}3.7 mm (maximum, 10.2 mm). Addressing intrafractional errors could further reduce margins to 3 mm. Conclusion: We demonstrated the clinical feasibility of an online adaptive image-guided, intensity-modulated prostate protocol on a standard linear accelerator to correct 6 degrees of freedom of internal organ motion, allowing safe and straightforward implementation of margin reduction and dose escalation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Head and Neck Margin Reduction With Adaptive Radiation Therapy: Robustness of Treatment Plans Against Anatomy Changes

Purpose: We set out to investigate loss of target coverage from anatomy changes in head and neck cancer patients as a function of applied safety margins and to verify a cone beam computed tomography (CBCT)–based adaptive strategy with an average patient anatomy to overcome possible target underdosage. Methods and Materials: For 19 oropharyngeal cancer patients, volumetric modulated arc therapy treatment plans (2 arcs; simultaneous integrated boost, 70 and 54.25 Gy; 35 fractions) were automatically optimized with uniform clinical target volume (CTV)–to–planning target volume margins of 5, 3, and 0 mm. We applied b-spline CBCT–to–computed tomography (CT) deformable registration to allow recalculation of the dose on modified CT scans (planning CT deformed to daily CBCT following online positioning) and dose accumulation in the planning CT scan. Patients with deviations in primary or elective CTV coverage >2 Gy were identified as candidates for adaptive replanning. For these patients, a single adaptive intervention was simulated with an average anatomy from the first 10 fractions. Results: Margin reduction from 5 mm to 3 mm to 0 mm generally led to an organ-at-risk (OAR) mean dose (D{sub mean}) sparing of approximately 1 Gy/mm. CTV shrinkage was mainly seen in the elective volumes (up to 10%), likely related to weight loss. Despite online repositioning, substantial systematic errors were present (>3 mm) in lymph node CTV, the parotid glands, and the larynx. Nevertheless, the average increase in OAR dose was small: maximum of 1.2 Gy (parotid glands, D{sub mean}) for all applied margins. Loss of CTV coverage >2 Gy was found in 1, 3, and 7 of 73 CTVs, respectively. Adaptive intervention in 0-mm plans substantially improved coverage: in 5 of 7 CTVs (in 6 patients) to <2 Gy of initially planned. Conclusions: Volumetric modulated arc therapy head and neck cancer treatment plans with 5-mm margins are robust for anatomy changes and show a modest increase in OAR dose. Margin reduction improves OAR sparing with approximately 1 Gy/mm at the expense of target coverage in a subgroup of patients. Patients at risk of CTV underdosage >2 Gy in 0-mm plans may be identified early in treatment using dose accumulation. A single intervention with an average anatomy derived from CBCT effectively mitigates discrepancies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implications of CT noise and artifacts for quantitative {sup 99m}Tc SPECT/CT imaging

Purpose: This paper evaluates the effects of computed tomography (CT) image noise and artifacts on quantitative single-photon emission computed-tomography (SPECT) imaging, with the aim of establishing an appropriate range of CT acquisition parameters for low-dose protocols with respect to accurate SPECT attenuation correction (AC). Methods: SPECT images of two geometric and one anthropomorphic phantom were reconstructed iteratively using CT scans acquired at a range of dose levels (CTDI{sub vol} = 0.4 to 46 mGy). Resultant SPECT image quality was evaluated by comparing mean signal, background noise, and artifacts to SPECT images reconstructed using the highest dose CT for AC. Noise injection was performed on linear-attenuation (μ) maps to determine the CT noise threshold for accurate AC. Results: High levels of CT noise (σ ∼ 200–400 HU) resulted in low μ-maps noise (σ ∼ 1%–3%). Noise levels greater than ∼10% in 140 keV μ-maps were required to produce visibly perceptible increases of ∼15% in {sup 99m}Tc SPECT images. These noise levels would be achieved at low CT dose levels (CTDI{sub vol} = 4 μGy) that are over 2 orders of magnitude lower than the minimum dose for diagnostic CT scanners. CT noise could also lower (bias) the expected μ values. The relative error in reconstructed SPECT signal trended linearly with the relative shift in μ. SPECT signal was, on average, underestimated in regions corresponding with beam-hardening artifacts in CT images. Any process that has the potential to change the CT number of a region by ∼100 HU (e.g., misregistration between CT images and SPECT images due to motion, the presence of contrast in CT images) could introduce errors in μ{sub 140} {sub keV} on the order of 10%, that in turn, could introduce errors on the order of ∼10% into the reconstructed {sup 99m}Tc SPECT image. Conclusions: The impact of CT noise on SPECT noise was demonstrated to be negligible for clinically achievable CT parameters. Because CT dose levels that affect SPECT quantification is low (CTDI{sub vol} ∼ 4 μGy), the low dose limit for the CT exam as part of SPECT/CT will be guided by CT image quality requirements for anatomical localization and artifact reduction. A CT technique with higher kVp in combination with lower mAs is recommended when low-dose CT images are used for AC to minimize beam-hardening artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of the Gemini Planet Imager Non-redundant Mask and Spectroscopy of Two Close-separation Binaries: HR 2690 and HD 142527

The Gemini Planet Imager (GPI) contains a 10-hole non-redundant mask (NRM), enabling interferometric resolution in complement to its coronagraphic capabilities. The NRM operates both in spectroscopic (integral field spectrograph, henceforth IFS) and polarimetric configurations. NRM observations were taken between 2013 and 2016 to characterize its performance. Most observations were taken in spectroscopic mode, with the goal of obtaining precise astrometry and spectroscopy of faint companions to bright stars. We find a clear correlation between residual wavefront error measured by the adaptive optic system and the contrast sensitivity by comparing phase errors in observations of the same source, taken on different dates. We find a typical 5σ contrast sensitivity of (2–3) × 10 –3 at $~λ/D$. We explore the accuracy of spectral extraction of secondary components of binary systems by recovering the signal from a simulated source injected into several data sets. We outline data reduction procedures unique to GPI's IFS and describe a newly public data pipeline used for the presented analyses. We demonstrate recovery of astrometry and spectroscopy of two known companions to HR 2690 and HD 142527. NRM+polarimetry observations achieve differential visibility precision of σ ~ 0.4% in the best case. We discuss its limitations on Gemini-S/GPI for resolving inner regions of protoplanetary disks and prospects for future upgrades. We summarize lessons learned in observing with NRM in spectroscopic and polarimetric modes.

79 ASTRONOMY AND ASTROPHYSICS↗

Data Trend Shifts Induced by Method of Concentration for Trace Metals in Seawater: Automated Online Preconcentration vs Borohydride Reductive Coprecipitation of Nearshore Seawater Samples for Analysis of Ni, Cu, Zn, Cd, and Pb via ICP-MS

This research compares performance, reproducibility, and detection limits of ambient seawater analysis for trace metals using both borohydride reductive co-precipitation and an automated chelation column (seaFAST™ 2) co-preconcentration for matrix interferent elimination on total and dissolved grab samples in nearshore to marine waters, over a broad concentration range, prior to ICP-MS injection. A move to an online preconcentration method both minimizes sample preparation, and eliminates correction errors when accounting for trace impurities in precipitated samples, induced via reagents. The reproducability of the online preconcentration method described, coupled with low blanks and method detection limits (MDLs), demonstrates an effective move to an automated procedure using ethylenediaminetriacetic and iminodiacetate acid chelation exchange resin and multi-analyte determination via ICP-MS for total and dissolved Ni, Cu, Zn, Cd, and Pb in marine water samples. Average CASS-5 recoveries using the online preconcentration method (n=9) were 109±7%, 104±5%, 103±7%, 101±3%, and 86±8% respectively. The MDLs obtained from the automated method for Ni, Cu, Zn, Cd and Pb were 3.3, 1.8, 13.5, 4, and 10 times lower, respectively, than for the Borohydride method. There were statistically significant differences between the methods for CASS-5 recoveries of Ni, Cu, Zn (p < 0.0001), and Pb (p = 0.0024). Comparison of methods gave high concordance (rC = 0.90) between methods for total and dissolved Ni, Cu, Zn, and Pb, and total Cd.

seaFAST, borohydride, seawater, Ethylenediaminetet↗

SCIFLI HORIS Windowpane Optical Analysis

This NASA Technical Memorandum summarizes windowpane optical analyses for the OSIRIS-REx (Origins, Spectral Interpretation, Resource Identification and Security Regolith Explorer) mission [1] supported by the SCIFLI (Scientifically Calibrated In-Flight Imagery) team [2] at NASA Langley Research Center (NASA LaRC). The SCIFLI team led a NASA multi-center team in characterization of fused silica (FS) and anti-reflective coated (AR-coated) sapphire materials for use as aircraft windowpanes. These materials were needed for the Hypervelocity OSIRIS-REx Reentry Imaging & Spectroscopy (HORIS) mission and were tested to generate performance parameters relevant to the flight environment. Some of the assessed parameters included optical quality, transmittance, reflectance, color balance, birefringence, transmitted wavefront error, wedge, and haziness of the windows. In order to evaluate the material characteristics in a uniform manner, several criteria were held constant. For example, the physical dimensions of the test articles were held constant (i.e., 17-inch diameter aircraft windowpane and 2-inch diameter witness samples). In this way, the comparison of test results from one material specimen to another was invariant with regard to the manner in which the tests were conducted. This also reduced the variability in how the data were reported. As a result, the results shown in this report, including test data generated by NASA can be used for windowpane material evaluation and future material design trades. Window designers can use the data and the testing method along with the testing matrices to efficiently match material performance to their design and mission objectives and requirements. Standardized testing methodologies and data reduction procedures are described in this report. Unless otherwise noted in the data itself, all the windowpane materials were tested in order to characterize their performance for the HORIS mission. One appendix has been included in this report. These include detailed wavefront interferograms of transmitted wavefront error and optical wedge used in the generation of aggregated material performance.

SCIFLI↗

Micro Fourier Transform Profilometry (μFTP): 3D shape measurement at 10,000 frames per second

We report that fringe projection profilometry is a well-established technique for optical 3D shape measurement. However, in many applications, it is desirable to make 3D measurements at very high speed, especially with fast moving or shape changing objects. In this work, we demonstrate a new 3D dynamic imaging technique, Micro Fourier Transform Profilometry (μFTP), which can realize an acquisition rate up to 10,000 3D frame per second (fps). The high measurement speed is achieved by the number of patterns reduction as well as high-speed fringe projection hardware. In order to capture 3D information in such a short period of time, we focus on the improvement of the phase recovery, phase unwrapping, and error compensation algorithms, allowing to reconstruct an accurate, unambiguous, and distortion-free 3D point cloud with every two projected patterns. We also develop a high-frame-rate fringe projection hardware by pairing a high-speed camera and a DLP projector, enabling binary pattern switching and precisely synchronized image capture at a frame rate up to 20,000 fps. Lastly, based on this system, we demonstrate high-quality textured 3D imaging of 4 transient scenes: vibrating cantilevers, rotating fan blades, flying bullet, and bursting balloon, which were previously difficult or even unable to be captured with conventional approaches.

3D shape measurement↗

Assessing Historical Variability of South Asian Monsoon Lows and Depressions With an Optimized Tracking Algorithm

Abstract Cyclonic low‐pressure systems (LPS) produce abundant rainfall in South Asia, where they are traditionally categorized as monsoon lows, monsoon depressions, and more intense cyclonic storms. The India Meteorological Department (IMD) has tracked monsoon depressions for over a century, finding a large decline in their number in recent decades, but their methods have changed over time and do not include monsoon lows. This study presents a fast, objective algorithm for identifying monsoon LPS and uses it to assess interannual variability and trends in reanalyses. Variables and thresholds used in the algorithm are selected to best match a subjectively analyzed LPS data set while minimizing disagreement between four reanalyses in a training period. The stream function of 850 hPa horizontal wind is found to be optimal in this sense; it is less noisy than vorticity and represents the complete nondivergent wind, even when flow is not geostrophic. Using this algorithm, LPS statistics are computed for five reanalyses, and none show a detectable trend in monsoon depression counts since 1979. Both the Japanese 55‐year Reanalysis (JRA‐55) and the IMD data set show a step‐like reduction in depression counts when they began using geostationary satellite data, in 1979 and 1982, respectively; the 1958–2018 linear trend in JRA‐55, however, is smaller than in the IMD data set, and its error bar includes 0. There are more LPS in seasons with above‐average monsoon rainfall and in La Niña years, but few other large‐scale modes of interannual variability are found to modulate LPS counts, lifetimes, or track length consistently across reanalyses.

54 ENVIRONMENTAL SCIENCES↗

APOSTLE: 11 TRANSIT OBSERVATIONS OF TrES-3b

The Apache Point Survey of Transit Lightcurves of Exoplanets (APOSTLE) observed 11 transits of TrES-3b over two years in order to constrain system parameters and look for transit timing and depth variations. We describe an updated analysis protocol for APOSTLE data, including the reduction pipeline, transit model, and Markov Chain Monte Carlo analyzer. Our estimates of the system parameters for TrES-3b are consistent with previous estimates to within the 2{sigma} confidence level. We improved the errors (by 10%-30%) on system parameters such as the orbital inclination (i {sub orb}), impact parameter (b), and stellar density ({rho}{sub *}) compared to previous measurements. The near-grazing nature of the system, and incomplete sampling of some transits, limited our ability to place reliable uncertainties on individual transit depths and hence we do not report strong evidence for variability. Our analysis of the transit timing data shows no evidence for transit timing variations and our timing measurements are able to rule out super-Earth and gas giant companions in low-order mean motion resonance with TrES-3b.

79 ASTRONOMY AND ASTROPHYSICS↗

Cerebral perfusion computed tomography deconvolution via structure tensor total variation regularization

Purpose: Cerebral perfusion computed tomography (PCT) imaging as an accurate and fast acute ischemic stroke examination has been widely used in clinic. Meanwhile, a major drawback of PCT imaging is the high radiation dose due to its dynamic scan protocol. The purpose of this work is to develop a robust perfusion deconvolution approach via structure tensor total variation (STV) regularization (PD-STV) for estimating an accurate residue function in PCT imaging with the low-milliampere-seconds (low-mAs) data acquisition. Methods: Besides modeling the spatio-temporal structure information of PCT data, the STV regularization of the present PD-STV approach can utilize the higher order derivatives of the residue function to enhance denoising performance. To minimize the objective function, the authors propose an effective iterative algorithm with a shrinkage/thresholding scheme. A simulation study on a digital brain perfusion phantom and a clinical study on an old infarction patient were conducted to validate and evaluate the performance of the present PD-STV approach. Results: In the digital phantom study, visual inspection and quantitative metrics (i.e., the normalized mean square error, the peak signal-to-noise ratio, and the universal quality index) assessments demonstrated that the PD-STV approach outperformed other existing approaches in terms of the performance of noise-induced artifacts reduction and accurate perfusion hemodynamic maps (PHM) estimation. In the patient data study, the present PD-STV approach could yield accurate PHM estimation with several noticeable gains over other existing approaches in terms of visual inspection and correlation analysis. Conclusions: This study demonstrated the feasibility and efficacy of the present PD-STV approach in utilizing STV regularization to improve the accuracy of residue function estimation of cerebral PCT imaging in the case of low-mAs.

60 APPLIED LIFE SCIENCES↗

The false lock performance of Costas loops with hard-limited in-phase channel

The ability of a Costas loop to false lock on a data sideband is a problem which must be dealt with in the design of suppressed-carrier receivers which employ such loops for carrier reconstruction. For conventional Costas loops wherein the error signal is formed from the product of two analog signals, the false lock problem has recently been investigated by the author and others and is now well understood. For implementation reasons associated with the reduction of dc offsets, it is often desirable to hard-limit the output of the in-phase channel and replace the analog multiplier which forms the above product with a chopper-type device. The false lock behavior of such a Costas loop with hard-limited in-phase channel is quite different from that of the conventional Costas loop and is the subject of investigation in this paper. Results are also presented for a modified version of the Costas loop wherein the quadrature arm filter is removed.

Simon, M. K.↗

IUE data reduction: Wavelength determinations and line identifications using a VAX/750 computer

A fully automated, interactive system for determining the wavelengths of features in extracted IUE spectra is described. Wavelengths are recorded from video displays of expanded plots of individual orders using a movable cursor, and then corrected for IUE wavelength scale errors. The estimated accuracy of an individual wavelength in the final tabulation is 0.050 A. Such lists are ideally suited for line identification work using the method of wavelength coincidence statistics (WCS). The results of WCS studies of the ultraviolet spectra of the chemically peculiar (CP) stars iota Coronae Borealis and kappa Camcri. Aside from confirming a number of previously reported aspects of the abundance patterns in these stars, the searches produced some interesting, new discoveries, notably the presence of Hf in the spectrum of kappa Camcri. The implications of this work for theories designed to account for anomalous abundances in chemically peculiar stars are discussed.

Davidson, J. P.↗

Improving Computational Efficiency of Mechanical Finite Element Method Simulations for PV Modules: Preprint

In this work we have elucidated the trade off between structural mechanics FEM model accuracy and computation time by employing lower fidelity viscoelastic models. Results indicate that computation time can easily be cut in half while only expecting a potential maximum error of 10 % by considering lower fidelity models. A novel approach to produce the Prony Series fit for viscoelastic characterization has also been presented. Employing this approach, we were able to achieve a further 10 % reduction in computation time without further sacrificing simulation accuracy.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Efficient, direct compilation of SU(N) operations into SNAP & Displacement gates

We present a function which connects the parameter of a previously published short sequence of selective number-dependent arbitrary phase (SNAP) and displacement gates acting on a qudit encoded into the Fock states of a superconducting cavity, $V_k(\alpha)=D(\alpha)R_\pi(k)D(-2\alpha)R_\pi(k)D(\alpha)$ to the angle of the Givens rotation $G(\theta)$ on levels $|k\rangle,|k+1\rangle$ that sequence approximates, namely $\alpha=\Phi(\theta) = \frac{\theta}{4\sqrt{k+1}}$. Previous publications left the determination of an appropriate $\alpha$ to numerical optimization at compile time. The map $\Phi$ gives us the ability to compile directly any $d$-dimensional unitary into a sequence of SNAP and displacement gates in $O(d^3)$ complex floating point operations with low constant prefactor, avoiding the need for numerical optimization. Numerical studies demonstrate that the infidelity of the generated gate sequence $V_k$ per Givens rotation $G$ scales as approximately $O(\theta^6)$. We find numerically that the error on compiled circuits can be made arbitrarily small by breaking each rotation into $m$$\theta/m$ rotations, with the full $d\times d$ unitary infidelity scaling as approximately $O(m^{-4})$. This represents a significant reduction in the computational effort to compile qudit unitaries either to SNAP and displacement gates or to generate them via direct low-level pulse optimization via optimal control.

Job, Joshua↗

The Importance of Addressing Disagreements Between Nominal and Effective Treatments During Bat Mortality Minimization Validation Studies

As the wind energy industry grows, so too does our need for effective and low-cost bat mortality minimization solutions. Despite knowledge gaps in our understanding of what drives bats to collide with spinning turbines, minimization solutions have shown success during validation studies. Curtailment has been consistently effective, reducing bat mortality from 33%-79%, depending on the curtailment scenario and species present. Several validation studies have demonstrated deterrent solutions, specifically ultrasonic deterrents, to be effective, but overall, more variable compared to curtailment solutions. Further, a study combining curtailment with ultrasonic deterrents produced encouraging results, finding that adding ultrasonic deterrents to turbines that were designated to curtail, significantly reduced mortality rates compared to curtailment only turbines. Despite positive results, the strength of inference achieved with validation studies is limited by methodological constraints associated with appropriately assigning fatalities to treatments. Because of the temporal separation between when a bat collides with a turbine and when it is discovered during a ground-based carcass survey, we must assign carcasses to a treatment that ran during the prior night(s). This process may introduce errors at multiple stages. First, for studies that rotate treatments among turbines, mortality surveyors must be confident that carcasses are 'fresh' such that mortalities are correctly assigned to the treatment from the previous night(s). Second, we must reconcile any misalignments between how we assign treatments and how we implement treatments (e.g., turbines assigned with a deterrent treatment may be implemented as another treatment when deterrent devices are not operating as designed). Finally, for curtailment solutions, it is critical to recognize that measured effects are a function of not just the treatment as implemented but the proportion of the night the treatment is realized (e.g., if wind speeds are greater than the curtailment treatment cut-in speed for the entire night, we cannot expect there to me any differences in mortality reduction relative to control turbines). Using a dataset collected between June and October 2017, that rotated 3 treatments (Deterrent Only, 5 m/s Curtail only, and 5 m/s Curtail & Deterrent) and 1 control condition across 16 turbines each night, we explored the importance and implications of accounting for potential errors in assigning fatalities to treatments. We present preliminary results comparing the mortality associated with error-corrected treatments and control conditions highlighting how the measured effect of a treatment (mortality) greatly depends on site specific implementation.

bats↗