Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy

Purpose: The aim of this study is to evaluate the dosimetric performance of a newly developed proton-sensitive polymer gel formulation for proton therapy dosimetry. Methods: Using passive scattered modulated and nonmodulated proton beams, the dose response of the gel was assessed. A next-generation optical CT scanner is used as the readout mechanism of the radiation-induced absorbance in the gel medium. Comparison of relative dose profiles in the gel to ion chamber profiles in water is performed. A simple and easily reproducible calibration protocol is established for routine gel batch calibrations. Relative stopping power ratio measurement of the gel medium was performed to ensure accurate water-equivalent depth dose scaling. Measured dose distributions in the gel were compared to treatment planning system for benchmark irradiations and quality of agreement is assessed using clinically relevant gamma index criteria. Results: The dosimetric response of the gel was mapped up to 600 cGy using an electron-based calibration technique. Excellent dosimetric agreement is observed between ion chamber data and gel. The most notable result of this work is the fact that this gel has no observed dose quenching in the Bragg peak region. Quantitative dose distribution comparisons to treatment planning system calculations show that most (>97%) of the gel dose maps pass the 3%/3 mm gamma criterion. Conclusions: This study shows that the new proton-sensitive gel dosimeter is capable of reproducing ion chamber dose data for modulated and nonmodulated Bragg peak beams with different clinical beam energies. The findings suggest that the gel dosimeter can be used as QA tool for millimeter range verification of proton beam deliveries in the dosimeter medium.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-573: Evaluation of EBT-XD Radiochromic Films for Verification of SBRT and SRS Treatment Delivery

Purpose: To evaluate the accuracy and precision of radiochromic films EBT-XD for quality control of stereotaxic body radiation therapy (SBRT) and stereotactic radiosurgery (SRS) plan delivery. Methods: A film cut in 3×10 cm2 strips was irradiated from 0 to 20 Gy in increments of 1 to 1.5 Gy using a 15 MeV electron beam. Triple-channel film calibration was completed 24 hours later by scanning the film strips on an Epson 10000XL scanner using a well-defined protocol. Several dose measurements of increasing complexity were subsequently performed with Varian iX accelerators. Pieces of films were first irradiated in a solid water phantom with 6 MV photon beams and a static gantry to doses spanning the calibration range, either in a single field or multiple fields setup. High dose (>15 Gy per fraction) IMRT plans were then measured. Finally films were irradiated with volumetric modulated arc therapy (VMAT) plans of lung and spinal lesions with prescribed doses per fraction between 8 and 20 Gy. The dose measured with the films was compared to the calculated dose from the Eclipse planning system using the Anisotropic Analytical Algorithm (AAA). Results: 77 dose measurements were compared to either ion chamber measurements or dose calculations (reference). The average dose difference between film measurements and reference was 0.7 % and the standard deviation was 1.3%. The maximum and minimum dose differences were +3.5% and −2% in the 4 Gy to 20 Gy range. Measured dose profiles of lung and vertebra treatment plans agreed very well with the calculations. Conclusion: EBT-XD films are a useful dosimeter for quality control of SBRT and SRS plan delivery. The measurement of a full 2D dose plane with high spatial resolution and acceptable dose accuracy make it an advantageous choice compared to other detectors such as ion chambers or diodes.

60 APPLIED LIFE SCIENCES↗

Radiation-Induced Lens Opacities among Interventional Cardiologists: Retrospective Assessment of Cumulative Eye Lens Doses

This study describes the retrospective lens dose calculation methods developed and applied within the European epidemiological study on radiation-induced lens opacities among interventional cardiologists. While one approach focuses on self-reported data regarding working practice in combination with available procedure-specific eye lens dose values, the second approach focuses on the conversion of the individual whole-body dose to eye lens dose. In contrast with usual dose reconstruction methods within an epidemiological study, a protocol is applied resulting in an individual distribution of possible cumulative lens doses for each recruited cardiologist, rather than a single dose estimate. In this way, the uncertainty in the dose estimate (from measurement uncertainty and variability among cardiologists) is represented for each individual. Eye lens dose and whole-body dose measurements have been performed in clinical practice to validate both methods, and it was concluded that both produce acceptable results in the framework of a dose-risk evaluation study. Optimal results were obtained for the dose to the left eye using procedure-specific lens dose data in combination with information collected on working practice. This method has been applied to 421 interventional cardiologists resulting in a median cumulative eye lens dose of 15.1 cSv for the left eye and 11.4 cSv for the right eye. From the individual cumulative eye lens dose distributions obtained for each cardiologist, maxima up to 9-10 Sv were observed, although with low probability. Since whole-body dose values above the lead apron are available for only a small fraction of the cohort and in many cases not for the entire working career, the second method has only been used to benchmark the results from the first approach. This study succeeded in improving the retrospective calculation of cumulative eye lens doses in the framework of radiation-induced risk assessment of lens opacities, but it remains dependent on self-reported information, which is not always reliable for early years. However, the calculation tools developed can also be used to make an assessment of the eye lens dose in current practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

TEST SYSTEM FOR EVALUATING SPENT NUCLEAR FUEL BENDING STIFFNESS AND VIBRATION INTEGRITY

Transportation packages for spent nuclear fuel (SNF) must meet safety requirements specified by federal regulations. For normal conditions of transport, vibration loads incident to transport must be considered. This is particularly relevant for high-burnup fuel (>45 GWd/MTU). As the burnup of the fuel increases, a number of changes occur that may affect the performance of the fuel and cladding in storage and during transportation. The mechanical properties of high-burnup de-fueled cladding have been previously studied by subjecting defueled cladding tubes to longitudinal (axial) tensile tests, ring-stretch tests, ring-compression tests, and biaxial tube burst tests. The objective of this study is to investigate the mechanical properties and behavior of both the cladding and the fuel in it under vibration/cyclic loads similar to the sustained vibration loads experienced during normal transport. The vibration loads to SNF rods during transportation can be characterized by dynamic, cyclic, bending loads. The transient vibration signals in a specified transport environment can be analyzed, and frequency, amplitude and phase components can be identified. The methodology being implemented is a novel approach to study the vibration integrity of actual SNF rod segments through testing and evaluating the fatigue performance of SNF rods at defined frequencies. Oak Ridge National Laboratory (ORNL) has developed a bending fatigue system to evaluate the response of the SNF rods to vibration loads. A three-point deflection measurement technique using linear variable differential transformers is used to characterize the bending rod curvature, and electromagnetic force linear motors are used as the driving system for mechanical loading. ORNL plans to use the test system in a hot cell for SNF vibration testing on high burnup, irradiated fuel to evaluate the pellet-clad interaction and bonding on the effective lifetime of fuel-clad structure bending fatigue performance. Technical challenges include pure bending implementation, remote installation and detachment of the SNF test specimen, test specimen deformation measurement, and identification of a driving system suitable for use in a hot cell. Surrogate test specimens have been used to calibrate the test setup and conduct systematic cyclic tests. The calibration and systematic cyclic tests have been used to identify test protocol issues prior to implementation in the hot cell. In addition, cyclic hardening in unidirectional bending and softening in reverse bending were observed in the surrogate test specimens. The interface bonding between the surrogate clad and pellets was found to impact the bending response of the surrogate rods; confirming this behavior in the actual spent fuel segments will be an important aspect of the hot cell test implementation,

reversal bending fatigue tester↗

Developing Science-based fueling protocols for 250-bar hydrogen tanks onboard hydrogen ferries: Experiments and modeling

Combined modeling and experimental studies are reported of the fueling of a large (28 kg capacity) 250-bar Type IV hydrogen tank of the type being deployed on early hydrogen ferries, such as the MV Sea Change. The primary goal was to determine how such tanks can be successfully fueled with hydrogen (state of charge greater than 97%) within 45 minutes without exceeding the 82 °C temperature limit for such tanks. The modeling studies show that a gas injector is needed to avoid thermal stratification during hydrogen fueling which can result in potential hot spots. Empirically, precooling of the hydrogen to 0 °C was found to be needed in some of the cases examined, as ambient conditions greatly affected the need for a precooling to achieve the 45-minute fill time desired by end users. The experimental results afforded a calibration of the engineering model SOFIL for these large 250-bar tanks, which now enables using SOFIL to predict volume-averaged hydrogen fueling temperatures to an accuracy of ±2.7°C for these tanks. The model can therefore be used to evaluate potential scenarios for development of a standardized fueling methodology for ferries utilizing large Type-IV tanks.

08 HYDROGEN↗

Nb 2 O 5 Protection Layers for Hydrogen Evolution by p-InP Photocathodes in Acidic Electrolytes

Coatings of HfO 2 , Ta 2 O 5 , TiO 2 , and Nb 2 O 5 were evaluated as protection layers for p-InP photocathodes in aqueous acidic electrolytes. Each candidate protection layer was characterized based on interfacial conduction of photogenerated electrons, the thermodynamic and kinetic stability of the overlayer over the relevant potential and pH range for cathodic fuel-forming half-reactions, and inhibition of the primary anodic and/or chemical dissolution processes that limit electrode stability. The conduction of photogenerated electrons and inhibition of anodic oxidation was evaluated using V 3+ / 2+ in 5.0 M HCl(aq) as a one-electron redox couple with a potential close to that of hydrogen evolution in acidic media. Failure modes due to cathodic plating of metal, as well as anodic dissolution and chemical dissolution processes, were evaluated for photocathodes made from etched p-InP, platinized p-InP, and p-InP photoelectrodes that had been coated with the various oxide films and then platinized for use in photoelectrochemical hydrogen evolution in acidic aqueous electrolytes. Nb 2 O 5 best met all of the criteria, contrasting with TiO 2 , which is thermodynamically and kinetically unstable in acid over the potential range relevant for the hydrogen evolution and/or CO 2 reduction electrochemical half-reactions. Furthermore, these protocols should be useful for other materials and semiconductors to determine the effectiveness of protection layers for photocathodes.

Electrodes↗

Evaluation of the Radioactive Material Released in the Harborview Research and Training Building and Some Implications for Emergency Response

On 2 May 2019, during the 137 Cs source recovery operation, a source capsule in a research irradiator containing approximately 77.1 TBq was breached. Based on a geometric reconstruction analysis of the damage to the capsule, approximately 46.3 GBq (0.04%) was impacted by the chop saw (grinder) inside a mobile hot cell on the loading dock at the University of Washington Harborview Research and Training (HRT) Building. A very small fraction of the material impacted, less than 1%, was released from the mobile hot cell and then to the rest of the HRT Building. The objectives of this project were to assess the accidental release of 137 CsCl and its implications related to emergency response methods and the ramifications of 137 CsCl transport. The phenomenology of this event was also compared with past alkali halide dispersal events. The vast number of measurements and samples collected by the remediation contractors, the Department of Energy’s Nuclear Emergency Support Team, and the small number of retrospective samples collected by the authors informed the analysis. The techniques included (1) autoradiography and electron microscopy of samples collected from the HRT Building and the irradiator, (2) 3D visualization of deposition on surfaces and within the ventilation system, and (3) a study of the damage to the source capsule to evaluate the Cs particle size and particle composition due to the grinding accident. Subsequently, the cesium contaminant transport through the numerous pathways in the building was reconstructed to assess the deposition on surfaces as a function of particle size. Furthermore, the implications for emergency response are relevant to data quality and management. A Data Quality Objective guides data collection methods so that they have appropriate accuracy and precision for the intended application. Recommendations were made with respect to the sample collection protocols and archiving of samples.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

SU-D-12A-06: A Comprehensive Parameter Analysis for Low Dose Cone-Beam CT Reconstruction

Purpose: There is always a parameter in compressive sensing based iterative reconstruction (IR) methods low dose cone-beam CT (CBCT), which controls the weight of regularization relative to data fidelity. A clear understanding of the relationship between image quality and parameter values is important. The purpose of this study is to investigate this subject based on experimental data and a representative advanced IR algorithm using Tight-frame (TF) regularization. Methods: Three data sets of a Catphan phantom acquired at low, regular and high dose levels are used. For each tests, 90 projections covering a 200-degree scan range are used for reconstruction. Three different regions-of-interest (ROIs) of different contrasts are used to calculate contrast-to-noise ratios (CNR) for contrast evaluation. A single point structure is used to measure modulation transfer function (MTF) for spatial-resolution evaluation. Finally, we analyze CNRs and MTFs to study the relationship between image quality and parameter selections. Results: It was found that: 1) there is no universal optimal parameter. The optimal parameter value depends on specific task and dose level. 2) There is a clear trade-off between CNR and resolution. The parameter for the best CNR is always smaller than that for the best resolution. 3) Optimal parameters are also dose-specific. Data acquired under a high dose protocol require less regularization, yielding smaller optimal parameter values. 4) Comparing with conventional FDK images, TF-based CBCT images are better under a certain optimally selected parameters. The advantages are more obvious for low dose data. Conclusion: We have investigated the relationship between image quality and parameter values in the TF-based IR algorithm. Preliminary results indicate optimal parameters are specific to both the task types and dose levels, providing guidance for selecting parameters in advanced IR algorithms. This work is supported in part by NIH (1R01CA154747-01)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electric Vehicle Communications Standards Testing and Validation - Phase II: SAE J2931/1

Vehicle to grid communication standards enable interoperability among vehicles, charging stations and utility providers and provide the capability to implement charge management. Several standards initiatives by the Society of Automobile Engineers (SAE), International Standards Organization and International Electrotechnical Commission (ISO/IEC), and ZigBee/HomePlug Alliance are developing requirements for communication messages and protocols. Recent work by the Electric Power Research Institute (EPRI) in collaboration with SAE and automobile manufacturers has identified vehicle to grid communication performance requirements and developed a test plan as part of SAE J2931/1 committee work. This laboratory test plan was approved by the SAE J2931/1 committee and included test configurations, test methods, and performance requirements to verify reliability, robustness, repeatability, maximum communication distance, and authentication features of power line carrier (PLC) communication modules at the internet protocol layer level. The goal of the testing effort was to select a communication technology that would enable automobile manufacturers to begin the development and implementation process. The EPRI/Argonne National Laboratory (ANL)/Pacific Northwest National Laboratory (PNNL) testing teams divided the testing so that results for each test could be presented by two teams, performing the tests independently. The PNNL team performed narrowband PLC testing including the Texas Instruments (TI) Concerto, Ariane Controls AC-CPM1, and the MAXIM Tahoe 2 evaluation boards. The scope of testing was limited to measuring the vendor systems communication performance between Electric Vehicle Support Equipment (EVSE) and plug-in electric vehicles (PEV). The testing scope did not address PEV’s CAN bus to PLC or PLC to EVSE (Wi-Fi, cellular, PLC Mains, etc.) communication integration. In particular, no evaluation was performed to delineate the effort needed to translate the IPv6/SEP2.0 messages to PEV’s CAN bus. The J2931/1 laboratory test results were presented to the SAE membership on March 20-22, 2012. The SAE committee decided to select HomePlug GreenPHY (HPGP) as the communication technology to use between the PEV and EVSE. No technology completely met all performance requirements. Both the MAXIM Tahoe 2 and TI Concerto met the 100Kbps throughput requirement, are estimated to meet the latency measurement performance, and met the control pilot impairment requirements. But HPGP demonstrated the potential to provide a data throughput rate of 10x of the requirement and either met or showed the potential to meet the other requirements with further development.

33 ADVANCED PROPULSION SYSTEMS↗

Evaluation of the Radioactive Material Release in the Harborview Research and Training Building and Implications for Emergency Response

On May 2, 2019, during the 137 Cs source recovery operation, a source capsule in a research irradiator containing approximately 77.1 TBq was breached. Based on a geometric reconstruction analysis of the damage to the capsule, approximately 46.3 GBq (0.04%) was impacted by the chop saw (grinder) inside a Mobile Hot Cell (MHC) on the loading dock at the University of Washington Harborview Research and Training (HRT) Building. A very small fraction of the material impacted, less than 1%) was released from the Mobile Hot Cell and then to the rest of the HRT Building. The objectives of this project were to assess the accidental release of 137 CsCl and its implications related to emergency response methods and the ramifications of 137 CsCl transport. The phenomenology of this event was also compared with past alkali halide dispersal events. The vast number of measurements and samples collected by the remediation contractors, the Department of Energy's Nuclear Emergency Support Team, and the small number of retrospective samples collected by the authors informed the analysis. The techniques included (1) autoradiography and electron microscopy of samples collected from the HRT Building and the irradiator, (2) 3D visualization of deposition on surfaces and within the ventilation system, and (3) a study of the damage to the source capsule to evaluate the Cs particle size and particle composition due to the grinding accident. Subsequently, the cesium contaminant transport through the numerous pathways in the building was reconstructed to assess the deposition on surfaces as a function of particle size. The implications for emergency response are relevant to data quality and management. A Data Quality Objective (DQO) guides data collection methods so that they have appropriate accuracy and precision for the intended application. Recommendations were made with respect to the sample collection protocols and sample archival.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of Inactivation Methods for Rift Valley Fever Virus in Mouse Microglia

Rift Valley fever phlebovirus (RVFV) is a highly pathogenic mosquito-borne virus with bioweapon potential due to its ability to be spread by aerosol transmission. Neurological symptoms are among the worst outcomes of infection, and understanding of pathogenesis mechanisms within the brain is limited. RVFV is classified as an overlap select agent by the CDC and USDA; therefore, experiments involving fully virulent strains of virus are tightly regulated. Here, we present two methods for inactivation of live virus within samples derived from mouse microglia cells using commercially available kits for the preparation of cells for flow cytometry and RNA extraction. Using the flow cytometry protocol, we demonstrate key differences in the response of primary murine microglia to infection with fully virulent versus attenuated RVFV.

60 APPLIED LIFE SCIENCES↗

Parameters Favorable to Intraprostatic Radiation Dose Escalation in Men With Localized Prostate Cancer

Purpose: To identify , within the framework of a current Phase I trial, whether factors related to intraprostatic cancer lesions (IPLs) or individual patients predict the feasibility of high-dose intraprostatic irradiation. Methods and Materials: Endorectal coil MRI scans of the prostate from 42 men were evaluated for dominant IPLs. The IPLs, prostate, and critical normal tissues were contoured. Intensity-modulated radiotherapy plans were generated with the goal of delivering 75.6 Gy in 1.8-Gy fractions to the prostate, with IPLs receiving a simultaneous integrated boost of 3.6 Gy per fraction to a total dose of 151.2 Gy, 200% of the prescribed dose and the highest dose cohort in our trial. Rectal and bladder dose constraints were consistent with those outlined in current Radiation Therapy Oncology Group protocols. Results: Dominant IPLs were identified in 24 patients (57.1%). Simultaneous integrated boosts (SIB) to 200% of the prescribed dose were achieved in 12 of the 24 patients without violating dose constraints. Both the distance between the IPL and rectum and the hip-to-hip patient width on planning CT scans were associated with the feasibility to plan an SIB (p = 0.002 and p = 0.0137, respectively). Conclusions: On the basis of this small cohort, the distance between an intraprostatic lesion and the rectum most strongly predicted the ability to plan high-dose radiation to a dominant intraprostatic lesion. High-dose SIB planning seems possible for select intraprostatic lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and performance of AI agents interfacing with an atomic layer deposition tool

In this work, we introduce the design of an atomic layer deposition (ALD) reactor augmented with an AI interface for autonomous materials synthesis. Our modular design encapsulates the particularities of the hardware behind a Python interface that communicates with the ALD control software via transmission control protocol. This interface is compatible with model context protocol interfaces used in agentic frameworks. We have integrated our tool with a simple AI agent that leverages a large language model to transform user-supplied queries into ALD processes that are then run in our reactor. Our approach uses a JavaScript object notation schema to encode ALD processes. Our experimental results show that the AI interface does not impose a significant overhead to our control software, at least within our fastest 10 ms scale. We also carried out a detailed evaluation of the agent performance using leading models in two classes of tasks: basic instruction and process discovery tasks, where the agent is presented with a target material and needs to identify the correct ALD process compatible with the reactor configuration. Despite the simplicity of our agent design, we observed that most of the advanced models excelled at the instruction tasks. However, only recent models, such as o1, o3, GPT-5, and Claude Opus 4, performed well in process discovery tasks. We also observed significant variability in the response for the hardest challenges. While the results obtained are promising, we identify areas where AI research could improve the performance of agents for ALD.

47 OTHER INSTRUMENTATION↗

Expanding the genetic engineering toolbox for the metabolically flexible acetogen Eubacterium limosum

Abstract Acetogenic bacteria are an increasingly popular choice for producing fuels and chemicals from single carbon (C1) substrates. Eubacterium limosum is a promising acetogen with several native advantages, including the ability to catabolize a wide repertoire of C1 feedstocks and the ability to grow well on agar plates. However, despite its promise as a strain for synthetic biology and metabolic engineering, there are insufficient engineering tools and molecular biology knowledge to leverage its native strengths for these applications. To capitalize on the natural advantages of this organism, here we extended its limited engineering toolbox. We evaluated the copy number of three common plasmid origins of replication and devised a method of controlling copy number and heterologous gene expression level by modulating antibiotic concentration. We further quantitatively assessed the strength and regulatory tightness of a panel of promoters, developing a series of well-characterized vectors for gene expression at varying levels. In addition, we developed a black/white colorimetric genetic reporter assay and leveraged the high oxygen tolerance of E. limosum to develop a simple and rapid transformation protocol that enables benchtop transformation. Finally, we developed two new antibiotic selection markers—doubling the number available for this organism. These developments will enable enhanced metabolic engineering and synthetic biology work with E. limosum.

59 BASIC BIOLOGICAL SCIENCES↗

Studying microbially induced corrosion on glass using ToF-SIMS

Microbially induced corrosion (MIC) is an emerging topic that has huge environmental impacts, such as long-term evaluation of microbial interactions with radioactive waste glass, environmental cleanup and disposal of radioactive material, and weathering effects of microbes. Time-of-flight secondary ion mass spectrometry (ToF-SIMS), a powerful mass spectral imaging technique with high surface sensitivity, mass resolution, and mass accuracy, can be used to study biofilm effects on different substrates. Understanding how to prepare biofilms on MIC susceptible substrates is critical for proper analysis via ToF-SIMS. We present here a step-by-step protocol for preparing bacterial biofilms for ToF-SIMS analysis, comparing three biofilm preparation techniques: no desalination, centrifugal spinning (CS), and water submersion (WS). Comparisons of two desalinating methods, CS and WS, show a decrease in the media peaks up to 99% using CS and 55% using WS, respectively. Proper desalination methods also can increase biological signals by over four times for fatty acids using WS, for example. ToF-SIMS spectral results show chemical compositional changes of the glass exposed in a Paenibacillus polymyxa SCE2 biofilm, indicating its capability to probe microbiologically induced corrosion of solid surfaces. This represents the proper desalination technique to use without significantly altering biofilm structure and substrate for ToF-SIMS analysis. ToF-SIMS spectral results showed chemical compositional changes of the glass exposed by a Paenibacillus bacterial biofilm over 3-month inoculation. Finally, possible MIC products include various phosphate phase molecules not observed in any control samples with the highest percent increases when experimental samples were compared with biofilm control samples.

36 MATERIALS SCIENCE↗

Study of the effective point of measurement for ion chambers in electron beams by Monte Carlo simulation

In current dosimetry protocols for electron beams, for plane-parallel chambers, the effective point of measurement is at the front face of the cavity, and, for cylindrical chambers, it is at a point shifted 0.5r upstream from the cavity center. In this study, Monte Carlo simulations are employed to study the issue of effective point of measurement for both plane-parallel chambers and cylindrical thimble chambers in electron beams. It is found that there are two ways of determining the position of the effective point of measurement: One is to match the calculated depth-ionization curve obtained from a modeled chamber to a calculated depth-dose curve; the other is to match the electron fluence spectrum in the chamber cavity to that in the phantom. For plane-parallel chambers, the effective point of measurement determined by the first method is generally not at the front face of the chamber cavity, which is obtained by the second method, but shifted downstream toward the cavity center by an amount that could be larger than one-half a millimeter. This should not be ignored when measuring depth-dose curves in electron beams. For cylindrical chambers, these two methods also give different positions of the effective point of measurement: The first gives a shift of 0.5r, which is in agreement with measurements for high-energy beams and is the same as the value currently used in major dosimetry protocols; the latter gives a shift of 0.8r, which is closer to the value predicted by a theoretical calculation assuming no-scatter conditions. The results also show that the shift of 0.8r is more appropriate if the cylindrical chamber is to be considered as a Spencer-Attix cavity. In electron beams, since the water/air stopping-power ratio changes with depth in a water phantom, the difference of the two shifts (0.3r) will lead to an incorrect evaluation of the water/air stopping-power ratio at the point of measurement, thus resulting in a systematic error in determining the absorbed dose by cylindrical chambers. It is suggested that a shift of 0.8r be used for electron beam calibrations with cylindrical chambers and a shift of 0.4r-0.5r be used for depth-dose measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analyzing Data Movements and Identifying Techniques for Next-generation High-bandwidth Networks

High-bandwidth networks are poised to provide new opportunities in tackling large data challenges in today's scientific applications. However, increasing the bandwidth is not sufficient by itself; we need careful evaluation of future high-bandwidth networks from the applications’ perspective. We have investigated data transfer requirements of climate applications as a typical scientific example and evaluated how the scientific community can benefit from next generation high-bandwidth networks. We have experimented with current state-of-the-art data movement tools, and realized that there is no single solution for presetting transfer parameters for optimal use of the available bandwidth. Thus, we developed an adaptive transfer methodology for tuning and optimization in wide-area data transfers. This worked well with large files. However, typical scientific datasets may include many small files. Current filecentric data transfer protocols do not perform well with managing the transfer of small files, even when using parallel streams or concurrent transfers over high bandwidth networks. In order to overcome this problem, we develop a new block-based data movement method (in contrast to the current file-based methods) to improve data movement performance and efficiency in moving large scientific datasets that contain many small files. We implemented the new block-based data movement tool, which takes the approach of aggregating files into blocks and providing dynamic data channel management. In our work, we also realized that one of the major obstacles in use of high-bandwidth networks is the limitation in host system resources. 100Gbps is beyond the capacity of today’s commodity machine, since we need substantial amount of processing power and involvement of multiple cores to fill a 40Gbps or 100Gbps network. As a result, host system performance plays an important role in the use of highbandwidth networks. We have conducted a large number of experiments with our new block-based method and with current available file-based data movement tools. In this white paper, we describe future research problems and challenges for efficient use of next-generation science networks, based on the lessons learnt and the experiences gained with 100Gbps network applications.

100Gbps network applications↗

Heat pump concepts for nZEB Technology developments, design tools and testing of heat pump systems for nZEB in the USA: Country report IEA HPT Annex 40 Task 2, Task 3 and Task 4 of the USA

The IEA HPT Annex 40 "Heat pump concepts for Nearly Zero Energy Buildings" deals with the application of heat pumps as a core component of the HVAC system for Nearly or Net Zero energy buildings (nZEB). This report covers Task 2 on the system comparison and optimisation and Task 3 dedicated to the development of adapted technologies for nZEB and field monitoring results of heat pump systems in nZEB. In the US team three institutions are involved and have worked on the following projects: The Oak Ridge National Laboratory (ORNL) will summarize development activities through the field demonstration stage for several integrated heat pump (IHP) systems electric ground-source (GS-IHP) and air-source (AS-IHP) versions and an engine driven AS-IHP version. The first commercial GS-IHP product was just introduced to the market in December 2012. This work is a contribution to Task 3 of the Annex. The University of Maryland will contribute a software development project to Task 2 of the Annex. The software ThermCom evaluates occupied space thermal comfort conditions accounting for all radiative and convective heat transfer effects as well as local air properties. The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net Zero Energy Residential Test Facility (NZERTF). This residential building was constructed on the NIST campus and officially opened in summer 2013. During the first year, between July 2013 and June 2014, baseline performance of the NZERTF was monitored under a simulated occupancy protocol. The house was equipped with an air-to-air heat pump which included a dedicated dehumidification operating mode. Outdoor conditions, internal loads and modes of heat pump operation were monitored. Field study results with respect to heat pump operation will be reported and recommendations on heat pump optimization for a net zero energy building will be provided. This work is a contribution to Task 3 of the Annex.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗