Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Development of Environmentally Benign Heat Pump Water Heaters for the US Market

Improving energy efficiency in water heating applications is important to the nation's energy strategies. Water heating in residential and commercial buildings accounts for about 10% of U.S. buildings energy consumption. Heat pump water heating (HPWH) technology is a significant breakthrough in energy efficiency, as an alternative to electric resistance water heating. Heat pump technology has shown acceptable payback period with proper incentives and successful market penetration is emerging. However, current HPWH require the use of refrigerants with high Global Warming Potential (GWP). Furthermore, current system designs depend greatly on the backup resistance heaters when the ambient temperature is below freezing or when hot water demand increases. Finally, the performance of current HPWH technology degrades greatly as the water set point temperature exceeds 330 K. This paper presents the potential for carbon dioxide, CO2, as a natural, environmentally benign alternative refrigerant for HPWH technology. In this paper, we first describe the system design, implications and opportunities of operating a transcritical cycle. Next, a prototype CO2 HPWH design featuring flexible component evaluation capability is described. The experimental setup and results are then illustrated followed by a brief discussion on the measured system performance. The paper ends with conclusions and recommendations for the development of CO2 heat pump water heating technology suitable for the U.S. market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of Neutron Imaging to InvestigateFlow Through Fractures for EGS

This paper will describe ongoing efforts at Oak Ridge National Laboratory to develop a unique experimental capability for investigating flow through porous and fractured geological media using neutron imaging techniques. This capability is expected to support numerous areas of investigation associated with flow processes relevant to EGS including, but not limited to: experimental visualization and measurement of velocity profiles and other flow characteristics to better inform reduced-order modeling of flow through fractures; laboratory scale validation of flow models and simulators; and a 'real-time' tool for studying geochemical rock/fluid interactions by noninvasively measuring material effects such as precipitation and dissolution in EGS representative conditions. Neutron scattering and attenuation based techniques have many distinctive advantages over other radiographic imaging methods for studying certain types of physical processes because cold and thermal neutrons are more highly attenuated by materials with large Hydrogen compositions while they more easily penetrate higher Z materials, such as those used in structural applications. Experiments exploiting this behavior may therefore be devised to study flow behaviors in samples even when thick pressure vessel walls and large sample masses are present. The objective of this project is to develop an experimental setup and methodology for taking EGS representative core samples with engineered fractures and fracture features, subjecting them to a triaxial stress state at EGS representative temperatures (up to 300 degrees C), and pumping high pressure fluid through the sample while imaging and measuring fluid flow characteristics using high flux neutron beams. This effort will take advantage of signature Oak Ridge National Laboratory facilities, including the Spallation Neutron Source and High Flux Isotope Reactor, as well as its core expertise in Neutron Science. Towards this end, a geothermal pressure test cell and flow system has been developed that can accommodate 1.5 diameter, 6 long core samples and apply a radial confining pressure up to 10,000 psi with fluid flow pressures up to 5,000 psi. This cell has been specially designed to optimize the transmission of neutrons and permit improved imaging of the interior of the sample of interest. Proof of principle measurements of the system have been performed and will be discussed in this paper. Techniques for injecting fluid contrast agents to permit visualization and quantification of flow profiles are also being developed and will be described along with future development plans.

Polsky, Yarom↗

Electron Heating During Reconnection, and the New TREX Experiment

In the first part of the document the author presents some observations, theory and simulations related to electron pressure anisotropy, E||, adiabatic model, collisions, double layers, and E perp energization. The relevant experimental setup is sketched, and some preliminary results are given. It is concluded that at low beta parallel adiabatic motion breaks down → double layers and electrons holes, and E|| pre-energizes and confines electrons, leading to further energization by E perp .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessment of Radiation Background Variation for Moving Detection Systems

The introduction points out that radiation backgrounds fluctuate across very short distances: factors include geology, soil composition, altitude, building structures, topography, and other manmade structures; and asphalt and concrete can vary significantly over short distances. Brief descriptions are given of the detection system, experimental setup, and background variation measurements. It is concluded that positive and negative gradients can greatly reduce the detection sensitivity of an MDS: negative gradients create opportunities for false negatives (nondetection), and positive gradients create a potentially unacceptable FAR (above 1%); the location of use for mobile detection is important to understand; spectroscopic systems provide more information for screening out false alarms and may be preferred for mobile use; and mobile monitor testing at LANL accounts for expected variations in the background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Planned High-brightness Channeling Radiation Experiment at Fermilab's Advanced Superconducting Test Accelerator

In this contribution we describe the technical details and experimental setup of our study aimed at producing high-brightness channeling radiation (CR) at Fermilab’s new user facility the Advanced Superconducting Test Accelerator (ASTA). In the ASTA photoinjector area electrons are accelerated up to 40-MeV and focused to a sub-micron spot on a ~40 micron thick carbon diamond, the electrons channel through the crystal and emit CR up to 80-KeV. Our study utilizes ASTA’s long pulse train capabilities and ability to preserve ultra-low emittance, to produce the desired high average brightness.

43 PARTICLE ACCELERATORS↗

Target Station Design for the Mu2e Experiment

The Mu2e experiment at Fermilab is devoted to search for the conversion of a negative muon into an electron in the field of a nucleus without emission of neutrinos. One of the main parts of the Mu2e experimental setup is its Target Station in which negative pions are generated in interactions of the 8-GeV primary proton beam with a tungsten target. A large-aperture 5-T superconducting production solenoid (PS) enhances pion collection, and an S-shaped transport solenoid (TS) delivers muons and pions to the Mu2e detector. The heat and radiation shield (HRS) protects the PS and the first TS coils. A beam dump absorbs the spent beam. In order for the PS superconducting magnet to operate reliably the sophisticated HRS was designed and optimized for performance and cost. The beam dump was designed to absorb the spent beam and maintaining its temperature and air activation in the hall at the allowable level. Comprehensive MARS15 simulations have been carried out to optimize all the parts while maximizing muon yield. Results of simulations of critical radiation quantities and their implications on the overall Target Station design and integration will be reported.

43 PARTICLE ACCELERATORS↗

Update on the Code Intercomparison and Benchmark for Muon Fluence and Absorbed Dose Induced by an 18 GeV Electron Beam After Massive Iron Shielding

In 1974, Nelson, Kase and Svensson published an experimental investigation on muon shielding around SLAC high-energy electron accelerators [1]. They measured muon fluence and absorbed dose induced by 14 and 18 GeV electron beams hitting a copper/water beamdump and attenuated in a thick steel shielding. In their paper, they compared the results with the theoretical models available at that time. In order to compare their experimental results with present model calculations, we use the modern transport Monte Carlo codes MARS15, FLUKA2011 and GEANT4 to model the experimental setup and run simulations. The results are then compared between the codes, and with the SLAC data.

Fasso, A.↗

Ambient infrared laser ablation mass spectrometry (AIRLAB-MS) with plume capture by continuous flow solvent probe

A new experimental setup for spatially resolved ambient infrared laser ablation mass spectrometry (AIRLAB-MS) that uses an infrared microscope with an infinity-corrected reflective objective and a continuous flow solvent probe coupled to a Fourier transform ion cyclotron resonance mass spectrometer is described. The efficiency of material transfer from the sample to the electrospray ionization emitter was determined using glycerol/methanol droplets containing 1 mM nicotine and is .about.50%. This transfer efficiency is significantly higher than values reported for similar techniques.

36 MATERIALS SCIENCE↗

Heteronuclear Correlation SSNMR Spectroscopy with Indirect Detection under Fast Magic-Angle Spinning [Book Chapter]

The main focus of this chapter is to address experimental strategies on the subject by providing a hands-on guide to fast MAS experiments, with a particular focus on indirect detection. Although our experience is limited to our respective laboratories in Ames and Yokohama, we hope that our descriptions of experimental setups and optimization procedures are sufficiently general to be applicable to all modern instruments. The chapter is organized as follows. Section 2 below introduces briefly the fast MAS technology and its main advantages. In Section 3, we describe the hardware associated with this remarkable technology and provide practical advices on its use, including procedures for loading and unloading the samples, maintaining the probe, reducing t 1 noise, etc. In Section 4, we describe the principles and hands-on aspects of experiments involving the indirect detection of spin-1/2 and 14 N nuclei

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Two-stage Injection-locked Magnetron for Accelerators with Superconducting Cavities

A concept for a two-stage injection-locked CW magnetron intended to drive Superconducting Cavities (SC) for intensity-frontier accelerators has been proposed. The concept considers two magnetrons in which the output power differs by 15-20 dB and the lower power magnetron being frequency-locked from an external source locks the higher power magnetron. The injection-locked two-stage CW magnetron can be used as an RF power source for Fermilab's Project-X to feed separately each of the 1.3 GHz SC of the 8 GeV pulsed linac. We expect output/locking power ratio of about 30-40 dB assuming operation in a pulsed mode with pulse duration of ~ 8 ms and repetition rate of 10 Hz. The experimental setup of a two-stage magnetron utilising CW, S-band, 1 kW tubes operating at pulse duration of 1-10 ms, and the obtained results are presented and discussed in this paper.

43 PARTICLE ACCELERATORS↗

Beam Tests of a High Pressure Gas-Filled Cavity for a Muon Collider

One of the greatest challenges in constructing a Muon Collider is cooling the hot muons into a focused beam after their production. Because the beam must be cooled quickly before the muons decay, compact cooling designs require high gradient cavities inside strong magnetic fields. Unfortunately, due to focused field emission, an external magnetic field degrades the performance of the cavity below what is required for a muon collider. High-pressure gas inside the cavity has been proposed to bot h mitigate this effect, as well as serve as an absorber for transversely cooling the muon beam. A prototype of a high pressure gas-filled cavity is currently being studied at the Muon Test Area at Fermilab. The experimental setup as well as several measur ements of the physics and performance of the apparatus while operating in a 400-MeV proton beam will be discussed.

43 PARTICLE ACCELERATORS↗

Aeroelastic oscillations of a cantilever with structural nonlinearities: theory and numerical simulation.

Our study details the derivation of the nonlinear equations of motion for the axial, biaxial bending and torsional vibrations of an aeroelastic cantilever undergoing rigid body (pitch) rotation at the base. The primary attenstion is focussed on the geometric nonlinearities of the system, whereby the aeroelastic load is modeled by the theory of linear quasisteady aerodynamics. This modelling effort is intended to mimic the wind-tunnel experimental setup at the Royal Military College of Canada. While the derivation closely follows the work of Hodges and Dowell [1] for rotor blades, this aeroelastic system contains new inertial terms which stem from the fundamentally different kinematics than those exhibited by helicopter or wind turbine blades. Using the Hamilton’s principle, a set of coupled nonlinear partial differential equations (PDEs) and an ordinary differential equation (ODE) are derived which describes the coupled axial-bending-bending-torsion-pitch motion of the aeroelastic cantilever with the pitch rotation. The finite dimensional approximation of the coupled system of PDEs are obtained using the Galerkin projection, leading to a coupled system of ODEs. Subsequently, these nonlinear ODEs are solved numerically using the built-in MATLAB implicit ODE solver and the associated numerical results are compared with those obtained using Houbolt’s method. It is demonstrated that the system undergoes coalescence flutter, leading to a limit cycle oscillation (LCO) due to coupling between the rigid body pitching mode and teh flexible mode arising from the flapwise bending motion.

42 ENGINEERING↗

Coherent Transition Radiation Generated from Transverse Electron Density Modulation

Coherent Transition radiation (CTR) of a given frequency is commonly generated with longitudinal electron bunch trains. In this paper, we present a study of CTR properties produced from simultaneous electron transverse and longitudinal density modulation. We demonstrate via numerical simulations a simple technique to generate THz-scale frequencies from mm-scale transversely separated electron beamlets formed into a ps-scale bunch train. The results and a potential experimental setup are discussed.

43 PARTICLE ACCELERATORS↗

Re-Analysis of the RRR/SEG Fast Thermal Coupled Facility

The Rossendorf Research Reactor (RRR), or Rossendorfer Ringzonenreacktor, was an Argonaut type zero power research reactor located at the Rossendorf research facility in Dresden Germany. The RRR consists of an annular core surrounded by a gr¬aphite reflector. Inside the core is an additional removable internal graphite reflector. This internal reflector was replaced in December of 1972 with a rapid deployment lattice known as Schnelles Einsatz-Gitter (SEG). The insertion of the SEG experimental lattice leads to a fast-thermal coupled system with the annular RRR reactor being the thermal driver and the SEG being the fast insertion lattice. The RRR/SEG integral experimental setup was used to perform small sample reactivity measurements using the pile oscillator method. By loading the SEG lattice with specially designed unit cells, a specific adjoint spectra could be obtained (only SEG 6 had a special radial arrangement). With a nearly energy-independent adjoint spectrum, the slowing-down effect becomes a constant and essentially disappears, such that any chan¬¬¬¬ge in reactivity can be attributed to the absorption component of the sample material. SEG 4, 5, and 7 exhibit this characteristic. If the adjoint function is strongly energy-dependent, then the scattering component will dominate. In the case of both SEG 6 lattices, where the adjoint is also monotonously rising, the scattering effect will always be negative. This analysis aims to re-evaluate the central reactivity worths of different samples for the SEG 4, 5, 6, and 7 experiments using modern continuous energy monte-carlo.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Study of Fluctuations in Undulator Radiation in the IOTA Ring at Fermilab

We study turn-by-turn fluctuations in the number of emitted photons in an undulator, installed in the IOTA electron storage ring at Fermilab, with an InGaAs PIN photodiode and an integrating circuit. In this paper, we present a theoretical model for the experimental data from previous similar experiments and in our present experiment, we attempt to verify the model in an independent and a more systematic way. Moreover, in our experiment we consider the regime of very small fluctuation when the contribution from the photon shot noise is significant, whereas we believe it was negligible in the previous experiments. Accordingly, we present certain critical improvements in the experimental setup that let us measure such a small fluctuation.

43 PARTICLE ACCELERATORS↗

Demonstration of CW Accelerating Gradients on a Cryogen-Free Cryocooler Conduction-Cooled SRF Cavity

Conduction-cooling of superconducting radiofrequency (SRF) cavities using closedcycle cryocoolers can lead to compact linear accelerators by eliminating liquid helium and the associated infrastructure. In this paper, we present the first-ever experimental demonstration of continuous wave (cw) accelerating gradients on a niobium SRF cavity that is cooled without using liquid helium. In a newly developed experimental apparatus, a single-cell, 650 MHz niobium cavity was conductively coupled to a 2 W @ 4.2 K pulse tube cryocooler using a high-purity aluminium thermal link. The cw accelerating gradient slightly exceeded 1.5 MV/m, a limit imposed by our RF power supply. Using simple scaling, we project that the niobium cavity when coated with Nb3Sn and operated on the same experimental setup can produce >10 MV/m cw accelerating gradients.

43 PARTICLE ACCELERATORS↗

Submodule Capacitor Reduction for a 1 MVA SiC-Based Modular Multilevel Converter Motor Drive using High Frequency Common-Mode Voltage Injection

This paper describes a strategy to reduce the size of submodule capacitors of a 1 MVA, 0-1 kHz, 7-level modular multilevel converter (MMC) based medium voltage variable speed drive (MVVSD) using 1.7 kV SiC MOSFETs. Hardware designs of submodules to withstand high dv/dt and capacitor selection based on common mode voltage injection have been presented in literature. The issue with injection is the error in tracking of injected circulation current which results in fundamental frequency fluctuations in the submodule capacitor voltage. This paper presents a strategy for higher frequency sinusoidal common mode voltage based on more accurate tracking of the circulating current; realized through an improved control strategy combined with a higher switching frequency. Using the methods presented in this paper, a smaller submodule capacitance and reduced output current THD of the motor drive is achieved. A loss analysis model is proposed to evaluate the effect of the proposed strategy on the MMC efficiency. This helps balance the reduction in the capacitor against the increase in the losses as a result of increased switching frequency. Simulations and a down-scaled experimental setup are used to demonstrate this concept.

Potty, Karun↗