Search NASA⌕ Search

SEARCH · Search NASA

Results for “extrapolation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Dose calculation for photon-emitting brachytherapy sources with average energy higher than 50 keV: Report of the AAPM and ESTRO

Purpose: Recommendations of the American Association of Physicists in Medicine (AAPM) and the European Society for Radiotherapy and Oncology (ESTRO) on dose calculations for high-energy (average energy higher than 50 keV) photon-emitting brachytherapy sources are presented, including the physical characteristics of specific {sup 192}Ir, {sup 137}Cs, and {sup 60}Co source models. Methods: This report has been prepared by the High Energy Brachytherapy Source Dosimetry (HEBD) Working Group. This report includes considerations in the application of the TG-43U1 formalism to high-energy photon-emitting sources with particular attention to phantom size effects, interpolation accuracy dependence on dose calculation grid size, and dosimetry parameter dependence on source active length. Results: Consensus datasets for commercially available high-energy photon sources are provided, along with recommended methods for evaluating these datasets. Recommendations on dosimetry characterization methods, mainly using experimental procedures and Monte Carlo, are established and discussed. Also included are methodological recommendations on detector choice, detector energy response characterization and phantom materials, and measurement specification methodology. Uncertainty analyses are discussed and recommendations for high-energy sources without consensus datasets are given. Conclusions: Recommended consensus datasets for high-energy sources have been derived for sources that were commercially available as of January 2010. Data are presented according to the AAPM TG-43U1 formalism, with modified interpolation and extrapolation techniques of the AAPM TG-43U1S1 report for the 2D anisotropy function and radial dose function.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-104: An Examination of Dose in the Buildup and Build-Down Regions

Purpose: To examine dose in the buildup and build-down regions and compare measurements made with various models and dosimeters Methods: Dose was examined in a 30×30cm {sup 2} phantom of water-equivalent plastic with 10cm of backscatter for various field sizes. Examination was performed with radiochromic film and optically-stimulated-luminescent-dosimeter (OSLD) chips, and compared against a plane-parallel chamber with a correction factor applied to approximate the response of an extrapolation chamber. For the build-down region, a correction factor to account for table absorption and chamber orientation in the posterior-anterior direction was applied. The measurement depths used for the film were halfway through their sensitive volumes, and a polynomial best fit curve was used to determine the dose to their surfaces. This chamber was also compared with the dose expected in a clinical kernel-based computer model, and a clinical Boltzmann-transport-equation-based (BTE) computer model. The two models were also compared against each other for cases with air gaps in the buildup region. Results: Within 3mm, all dosimeters and models agreed with the chamber within 10% for all field sizes. At the entrance surface, film differed in comparison with the chamber from +90% to +15%, the BTE-model by +140 to +3%, and the kernel-based model by +20% to −25%, decreasing with increasing field size. At the exit surface, film differed in comparison with the chamber from −10% to −15%, the BTE-model by −53% to −50%, the kernel-based model by −55% to −57%, mostly independent of field size. Conclusion: The largest differences compared with the chamber were found at the surface for all field sizes. Differences decreased with increasing field size and increasing depth in phantom. Air gaps in the buildup region cause dose buildup to occur again post-gap, but the effect decreases with increasing phantom thickness prior to the gap.

60 APPLIED LIFE SCIENCES↗

Clinical introduction of image lag correction for a cone beam CT system

Purpose: Image lag in the flat-panel detector used for Linac integrated cone beam computed tomography (CBCT) has a degrading effect on CBCT image quality. The most prominent visible artifact is the presence of bright semicircular structure in the transverse view of the scans, known also as radar artifact. Several correction strategies have been proposed, but until now the clinical introduction of such corrections remains unreported. In November 2013, the authors have clinically implemented a previously proposed image lag correction on all of their machines at their main site in Amsterdam. The purpose of this study was to retrospectively evaluate the effect of the correction on the quality of CBCT images and evaluate the required calibration frequency. Methods: Image lag was measured in five clinical CBCT systems (Elekta Synergy 4.6) using an in-house developed beam interrupting device that stops the x-ray beam midway through the data acquisition of an unattenuated beam for calibration. A triple exponential falling edge response was fitted to the measured data and used to correct image lag from projection images with an infinite response. This filter, including an extrapolation for saturated pixels, was incorporated in the authors’ in-house developed clinical CBCT reconstruction software. To investigate the short-term stability of the lag and associated parameters, a series of five image lag measurement over a period of three months was performed. For quantitative analysis, the authors have retrospectively selected ten patients treated in the pelvic region. The apparent contrast was quantified in polar coordinates for scans reconstructed using the parameters obtained from different dates with and without saturation handling. Results: Visually, the radar artifact was minimal in scans reconstructed using image lag correction especially when saturation handling was used. In patient imaging, there was a significant reduction of the apparent contrast from 43 ± 16.7 to 15.5 ± 11.9 HU without the saturation handling and to 9.6 ± 12.1 HU with the saturation handling, depending on the date of the calibration. The image lag correction parameters were stable over a period of 3 months. The computational load was increased by approximately 10%, not endangering the fast in-line reconstruction. Conclusions: The lag correction was successfully implemented clinically and removed most image lag artifacts thus improving the image quality. Image lag correction parameters were stable for 3 months indicating low frequency of calibration requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-C-206-07: A Practical Sparse View Ultra-Low Dose CT Acquisition Scheme for PET Attenuation Correction in the Extended Scan Field-Of-View

Purpose: To further reduce CT dose, a practical sparse-view acquisition scheme is proposed to provide the same attenuation estimation as higher dose for PET imaging in the extended scan field-of-view. Methods: CT scans are often used for PET attenuation correction and can be acquired at very low CT radiation dose. Low dose techniques often employ low tube voltage/current accompanied with a smooth filter before backprojection to reduce CT image noise. These techniques can introduce bias in the conversion from HU to attenuation values, especially in the extended CT scan field-of-view (FOV). In this work, we propose an ultra-low dose CT technique for PET attenuation correction based on sparse-view acquisition. That is, instead of an acquisition of full amount of views, only a fraction of views are acquired. We tested this technique on a 64-slice GE CT scanner using multiple phantoms. CT scan FOV truncation completion was performed based on the published water-cylinder extrapolation algorithm. A number of continuous views per rotation: 984 (full), 246, 123, 82 and 62 have been tested, corresponding to a CT dose reduction of none, 4x, 8x, 12x and 16x. We also simulated sparse-view acquisition by skipping views from the fully-acquired view data. Results: FBP reconstruction with Q. AC filter on reduced views in the full extended scan field-of-view possesses similar image quality to the reconstruction on acquired full view data. The results showed a further potential for dose reduction compared to the full acquisition, without sacrificing any significant attenuation support to the PET. Conclusion: With the proposed sparse-view method, one can potential achieve at least 2x more CT dose reduction compared to the current Ultra-Low Dose (ULD) PET/CT protocol. A pre-scan based dose modulation scheme can be combined with the above sparse-view approaches, which can even further reduce the CT scan dose during a PET/CT exam.

60 APPLIED LIFE SCIENCES↗

SU-D-204-03: Comparison of Patient Positioning Methods Through Modeling of Acute Rectal Toxicity in Intensity Modulated Radiation Therapy for Prostate Cancer. Does Quality of Data Matter More Than the Quantity?

Purpose: To determine if differences in patient positioning methods have an impact on the incidence and modeling of grade >=2 acute rectal toxicity in prostate cancer patients who were treated with Intensity Modulated Radiation Therapy (IMRT). Methods: We compared two databases of patients treated with radiation therapy for prostate cancer: a database of 79 patients who were treated with 7 field IMRT and daily image guided positioning based on implanted gold markers (IGRTdb), and a database of 302 patients who were treated with 5 field IMRT and daily positioning using a trans-abdominal ultrasound system (USdb). Complete planning dosimetry was available for IGRTdb patients while limited planning dosimetry, recorded at the time of planning, was available for USdb patients. We fit Lyman-Kutcher-Burman (LKB) model to IGRTdb only, and Univariate Logistic Regression (ULR) NTCP model to both databases. We perform Receiver Operating Characteristics analysis to determine the predictive power of NTCP models. Results: The incidence of grade >= 2 acute rectal toxicity in IGRTdb was 20%, while the incidence in USdb was 54%. Fits of both LKB and ULR models yielded predictive NTCP models for IGRTdb patients with Area Under the Curve (AUC) in the 0.63 – 0.67 range. Extrapolation of the ULR model from IGRTdb to planning dosimetry in USdb predicts that the incidence of acute rectal toxicity in USdb should not exceed 40%. Fits of the ULR model to the USdb do not yield predictive NTCP models and their AUC is consistent with AUC = 0.5. Conclusion: Accuracy of a patient positioning system affects clinically observed toxicity rates and the quality of NTCP models that can be derived from toxicity data. Poor correlation between planned and clinically delivered dosimetry may lead to erroneous or poorly performing NTCP models, even if the number of patients in a database is large.

60 APPLIED LIFE SCIENCES↗

Specific features of magnetic phase diagram of an MnSi helimagnet

Magnetization curves of MnSi single crystals have been measured in a range of temperatures T = 5.5-35 K and magnetic field strengths H {<=} 11 kOe for H Parallel-To [1 1 1], [0 0 1], and [1 1 0]. Special attention has been paid to the temperature interval near T{sub N} = 28.8 K, where MnSi exhibits a transition to the state with a long-period helical magnetic structure. Some new features in the magnetic behavior of MnSi have been found. In particular, in an intermediate temperature region above the transition (28.8 K = T{sub N} {<=} T < 31.5 K), the dM(H)/dH curves exhibit anomalies that are not characteristic of the typical paramagnetic state. It is established that the line of the characteristic field H*(T) of this anomaly is a natural extrapolation of the temperature dependence of the field of the transition from a conical phase to an induced ferromagnetic phase observed at T < T{sub N}. It is concluded that the properties of MnSi in the indicated intermediate region are related to and governed by those of the conical phase (rather than of the A phase). Based on these data, magnetic phase diagrams of MnSi for H Parallel-To [1 1 1], [0 0 1], and [1 1 0] are plotted and compared to diagrams obtained earlier by other methods.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

How large is 'large N{sub c}' for nuclear matter?

We argue that a so far neglected dimensionless scale, the number of neighbors in a closely packed system, is relevant for the convergence of the large-N{sub c} expansion at high chemical potential. It is only when the number of colors is large w.r.t. this new scale ({approx} O(10)) that a convergent large-N{sub c} limit is reached. This provides an explanation as to why the large-N{sub c} expansion, qualitatively successful in vacuum QCD, fails to describe high baryo-chemical potential systems, such as nuclear matter. It also means that phenomenological claims about high-density matter based on large-N{sub c} extrapolations should be treated with caution. This work is based on [1].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Contribution of the Δ-isobar excitation mechanism to the pp → {pp}{sub s} π{sup 0} reaction

The differential cross section of the reaction pp → {pp}{sub s} π{sup 0}, where {pp}{sub s} is the proton pair in the {sup 1}S{sub 0} state at a small excitation energy E{sub pp} < 3 MeV, is calculated using the box diagram with the excitation of the Δ-isobar. The model demonstrates a clear bump observed in the experimental data at the beam energy of ∼0.6 GeV and the zero diproton outgoing angle; however, its absolute value strongly depends on the off-shell extrapolation of the πNΔ vertex factor and underestimates the data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Composition and optical properties of amorphous a-SiO{sub x}:H films with silicon nanoclusters

The phase composition and optical properties of hydrogenated amorphous films of silicon suboxide (a-SiO{sub x}:H) with silicon nanoclusters are studied. Ultrasoft X-ray emission spectroscopy show that silicon- suboxide films with various oxidation states and various amorphous silicon-cluster contents can be grown using dc discharge modulation. In films with an ncl-Si content of ∼50%, the optical-absorption edge is observed, whose extrapolation yields an optical band gap estimate of ∼3.2–3.3 eV. In the visible region, rather intense photoluminescence bands are observed, whose peak positions indicate the formation of silicon nanoclusters 2.5–4.7 nm in size in these films, depending on the film composition.

36 MATERIALS SCIENCE↗

Thermal stability of hydrogenated small-diameter carbon nanotubes

The initial stage of hydrogen desorption from fully hydrogenated carbon nanotubes (3.0) and (2.2) is numerically studied by the molecular dynamics method. The temperature dependence of the desorption rate is directly determined at T = 1800–2500 K. The characteristic desorption times are determined at temperatures outside this range by extrapolation. It is shown that hydrogen desorption leads to the appearance of electronic states in the band gap.

36 MATERIALS SCIENCE↗

Size Dependence of the Melting Point of Silicon Nanoparticles: Molecular Dynamics and Thermodynamic Simulation

The size dependence of the melting point of Si nanoparticles is investigated using molecular dynamics and thermodynamic simulation based on the Thomson’s formula. The atomistic modeling data obtained using the Stillinger–Weber potential agree with the results reported by other authors and thermodynamic-simulation data and predict a decrease in the melting point T{sub m} of Si nanoparticles with an increase in their reciprocal radius R{sup –1} according to linear law. The available experimental data predict lower T{sub m} values, including the limiting value T{sub m}{sup (∞)}, which corresponds to the linear extrapolation of experimental points to R{sup –1} → 0 (to the radius R → ∞); the underestimation is 200–300 K as compared with the reference melting point of silicon (1688 K). It is concluded that the molecular-dynamics data on T{sub m}(R{sup –1}) obtained using the Stillinger–Weber potential are more adequate than the available experimental data.

74 ATOMIC AND MOLECULAR PHYSICS↗

Structure of Lambda(1405) and threshold behavior of pi Sigma scattering

The scattering length and effective range of the pi-Sigma channel are studied in order to characterize the strangeness S = -1 meson-baryon scattering and the Lambda (1405) resonance. We examine various off-shell dependence of the amplitude in dynamical chiral models to evaluate the threshold quantities with the constraint at the KN threshold. We find that the pi-Sigma threshold parameters are important to the structure of the Lambda (1405) resonance and provide further constraints on the subthreshold extrapolation of the KN interaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparative Iron Oxide Nanoparticle Cellular Dosimetry and Response in Mice by the Inhalation and Liquid Cell Culture Exposure Routes

testing the rapidly growing number of nanomaterials requires large scale use of in vitro systems under the presumption that these systems are sufficiently predictive or descriptive of responses in in vivo systems for effective use in hazard ranking. We hypothesized that improved relationships between in vitro and in vivo models of experimental toxicology for nanomaterials would result from placing response data in vitro and in vivo on the same dose scale, the amount of material associated with cells (target cell dose). Methods: Balb/c mice were exposed nose-only to an aerosol of 12.8 nm (68.6 nm CMD, 19.9 mg/m3, 4 hours) super paramagnetic iron oxide particles, target cell doses were calculated and biomarkers of response anchored with histological evidence were identified by global transcriptomics. Representative murine epithelial and macrophage cell types were exposed in vitro to the same material in liquid suspension for four hours and levels nanoparticle regulated cytokine transcripts identified in vivo were quantified as a function of measured nanoparticle cellular dose. Results. Target tissue doses of 0.009-0.4 μg SPIO/cm2 lung led to an inflammatory response in the alveolar region characterized by interstitial inflammation and macrophage infiltration. In vitro, higher target tissue doses of ~1.2-4 μg SPIO/ cm2 of cells were required to induce transcriptional regulation of markers of inflammation, CXCL2 CCL3, in C10 lung epithelial cells. Estimated in vivo macrophage SPIO nanoparticle doses ranged from 1-100 pg/cell, and induction of inflammatory markers was observed in vitro in macrophages at doses of 8-35 pg/cell. Conclusions: Application of target tissue dosimetry revealed good correspondence between target cell doses triggering inflammatory processes in vitro and in vivo in the alveolar macrophage population, but not in the epithelial cells of the alveolar region. These findings demonstrate the potential for target tissue dosimetry to enable the more quantitative comparison of in vitro and in vivo systems advance their use for hazard assessment and extrapolation to humans. The mildly inflammogentic cellular doses experienced by mice were similar those calculated for humans exposed to the same at the existing permissible exposure limit of 10 mg/m3 iron oxide (as Fe).

Dosimetry↗

Optical constants of crystalline HfO2 for energy range 140-930 eV

We calculated the optical constants of the monoclinic phase of a HfO2 film from reflection spectra measured using synchrotron radiation in the spectral region from 143 eV to 927 eV, which includes the HfN4,5{sup -}, HfN2,3{sup -}, and OK absorption edges. The calculations were carried out using the Kramers-Kronig relations. It could be shown that the relation R(E){approx}E{sup -4} can be used for extrapolation of the experimental reflection spectrum of HfO2 (and probably of other heavy elements) for energies such that {theta}/{theta}c>3.7.

74 ATOMIC AND MOLECULAR PHYSICS↗

Water-Moderated and -Reflected Slabs of Uranium Oxyfluoride

A series of ten experiments were conducted at the Oak Ridge National Laboratory Critical Experiment Facility in December 1955, and January 1956, in an attempt to determine critical conditions for a slab of aqueous uranium oxyfluoride (UO2F2). These experiments were recorded in an Oak Ridge Critical Experiments Logbook and results were published in a journal of the American Nuclear Society, Nuclear Science and Engineering, by J. K. Fox, L. W. Gilley, and J. H. Marable (Reference 1). The purpose of these experiments was to obtain the minimum critical thickness of an effectively infinite slab of UO2F2 solution by extrapolation of experimental data. To do this the slab thickness was varied and critical solution and water-reflector heights were measured using two different fuel solutions. Of the ten conducted experiments eight of the experiments reached critical conditions but the results of only six of the experiments were published in Reference 1. All ten experiments were evaluated from which five critical configurations were judged as acceptable criticality safety benchmarks. The total uncertainty in the acceptable benchmarks is between 0.25 and 0.33 % ?k/keff. UO2F2 fuel is also evaluated in HEU-SOL-THERM-043, HEU-SOL-THERM-011, and HEU-SOL-THERM-012, but these those evaluation reports are for large reflected and unreflected spheres. Aluminum cylinders of UO2F2 are evaluated in HEU-SOL-THERM-050.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantum Monte Carlo Endstation for Petascale Computing

The major achievements enabled by QMC Endstation grant include * Performance improvement on clusters of x86 multi-core systems, especially on Cray XT systems * New and improved methods for the wavefunction optimizations * New forms of trial wavefunctions * Implementation of the full application on NVIDIA GPUs using CUDA The scaling studies of QMCPACK on large-scale systems show excellent parallel efficiency up to 216K cores on Jaguarpf (Cray XT5). The GPU implementation shows speedups of 10-15x over the CPU implementation on older generation of x86. We have implemented hybrid OpenMP/MPI scheme in QMC to take advantage of multi-core shared memory processors of petascale systems. Our hybrid scheme has several advantages over the standard MPI-only scheme. * Memory optimized: large read-only data to store one-body orbitals and other shared properties to represent the trial wave function and many-body Hamiltonian can be shared among threads, which reduces the memory footprint of a large-scale problem. * Cache optimized: the data associated with an active Walker are in cache during the compute-intensive drift-diffusion process and the operations on an Walker are optimized for cache reuse. Thread-local objects are used to ensure the data affinity to a thread. * Load balanced: Walkers in an ensemble are evenly distributed among threads and MPI tasks. The two-level parallelism reduces the population imbalance among MPI tasks and reduces the number of point-to-point communications of large messages (serialized objects) for the Walker exchange. * Communication optimized: the communication overhead, especially for the collective operations necessary to determine ET and measure the properties of an ensemble, is significantly lowered by using less MPI tasks. The multiple forms of parallelism afforded by QMC algorithms make them ideal candidates for acceleration in the many-core paradigm. We presented the results of our effort to port the QMCPACK simulation code to the NVIDIA CUDA GPU platform. We restructured the CPU algorithms to express additional parallelism, minimize GPU-CPU communication, and efficiently utilize the GPU memory hierarchy. Using mixed precision on GT200 GPUs and MPI for intercommunication and load balancing, we observe typical full-application speedups of approximately 10x to 15x relative to quad-core Xeon CPUs alone, while reproducing the double-precision CPU results within statistical error. We developed an all-electron quantum Monte Carlo (QMC) method for solids that does not rely on pseudopotentials, and used it to construct a primary ultra-high-pressure calibration based on the equation of state of cubic boron nitride. We computed the static contribution to the free energy with the QMC method and obtained the phonon contribution from density functional theory, yielding a high-accuracy calibration up to 900 GPa usable directly in experiment. We computed the anharmonic Raman frequency shift with QMC simulations as a function of pressure and temperature, allowing optical pressure calibration. In contrast to present experimental approaches, small systematic errors in the theoretical EOS do not increase with pressure, and no extrapolation is needed. This all-electron method is applicable to first-row solids, providing a new reference for ab initio calculations of solids and benchmarks for pseudopotential accuracy. We compared experimental and theoretical results on the momentum distribution and the quasiparticle renormalization factor in sodium. From an x-ray Compton-profile measurement of the valence-electron momentum density, we derived its discontinuity at the Fermi wavevector finding an accurate measure of the renormalization factor that we compared with quantum-Monte-Carlo and G0W0 calculations performed both on crystalline sodium and on the homogeneous electron gas. Our calculated results are in good agreement with the experiment. We have been studying the heat of formation for various Kubas complexes of molecular hydrogen on Ti(1,2)ethylene-nH2 using Diffusion Monte Carlo. This work has been started and is ongoing. We are studying systems involving 1 and 2 Ti bonding sites with up to 10 hydrogen molecules in numerous configurations. This work will establish a benchmark that will test the accuracy of density functional calculations and establish the feasibility of our methods for similar systems.

97 MATHEMATICS AND COMPUTING↗

RTSTEP Regional Transportation Simulation Tool for Evacuation Planning: Transportation Research and Analysis Computing Center (Final Report)

Large-scale evacuations from major cities during no-notice events - such as chemical or radiological attacks, hazardous material spills, or earthquakes - have an obvious impact on large regions rather than on just the directly affected area. The scope of impact includes the accommodation of emergency evacuation traffic throughout a very large area; the planning of resources to respond appropriately to the needs of the affected population; the placement of medical supplies and decontamination equipment; and the assessment and determination of primary escape routes, as well as routes for incoming emergency responders. Compared to events with advance notice, such as evacuations based on hurricanes approaching an affected area, the response to no-notice events relies exclusively on pre-planning and general regional emergency preparedness. Another unique issue is the lack of a full and immediate understanding of the underlying threats to the population, making it even more essential to gain extensive knowledge of the available resources, the chain of command, and established procedures. Given the size of the area affected, an advanced understanding of the regional transportation systems is essential to help with the planning for such events. The objectives of the work described here (carried out by Argonne National Laboratory) is the development of a multi-modal regional transportation model that allows for the analysis of different evacuation scenarios and emergency response strategies to build a wealth of knowledge that can be used to develop appropriate regional emergency response plans. The focus of this work is on the effects of no-notice evacuations on the regional transportation network, as well as the response of the transportation network to the sudden and unusual demand. The effects are dynamic in nature, with scenarios changing potentially from minute to minute. The response to a radiological or chemical hazard will be based on the time-delayed dispersion of such materials over a large area, with responders trying to mitigate the immediate danger to the population in a variety of ways that may change over time (e.g., in-place evacuation, staged evacuations, and declarations of growing evacuation zones over time). In addition, available resources will be marshaled in unusual ways, such as the repurposing of transit vehicles to support mass evacuations. Thus, any simulation strategy will need to be able to address highly dynamic effects and will need to be able to handle any mode of ground transportation. Depending on the urgency and timeline of the event, emergency responders may also direct evacuees to leave largely on foot, keeping roadways as clear as possible for emergency responders, logistics, mass transport, and law enforcement. This RTSTEP project developed a regional emergency evacuation modeling tool for the Chicago Metropolitan Area that emergency responders can use to pre-plan evacuation strategies and compare different response strategies on the basis of a rather realistic model of the underlying complex transportation system. This approach is a significant improvement over existing response strategies that are largely based on experience gained from small-scale events, anecdotal evidence, and extrapolation to the scale of the assumed emergency. The new tool will thus add to the toolbox available to emergency response planners to help them design appropriate generalized procedures and strategies that lead to an improved outcome when used during an actual event.

99 GENERAL AND MISCELLANEOUS↗

Radiation leukaemogenesis at low doses

This report provides a complete summary of the work undertaken and results obtained under US Department of Energy grant DF-FG02-05 ER 63947, Radiation leukaemogenesis at low doses. There is ample epidemiological evidence indicating that ionizing radiation is carcinogenic in the higher dose range. This evidence, however, weakens and carries increasing uncertainties at doses below 100-200 mSv. At these low dose levels the form of the dose-response curve for radiation-induced cancer cannot be determined reliably or directly from studies of human populations. Therefore animal, cellular and other experimental systems must be employed to provide supporting evidence on which to base judgements of risk at low doses. Currently in radiological protection a linear non-threshold (LNT) extrapolation of risk estimates derived from human epidemiological studies is used to estimate risks in the dose range of interest for protection purposes.

59 BASIC BIOLOGICAL SCIENCES↗