Search NASA⌕ Search

SEARCH · Search NASA

Results for “guide”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Percutaneous CT-Guided Treatment of Osteochondritis Dissecans of the Sacroiliac Joint

Osteochondritis dissecans (OCD) is a joint disorder that affects the articular cartilage and subchondral bone, most commonly at the knee. OCD of the sacroiliac joint is extremely rare. Management of OCD remains controversial, and surgery is often needed, especially when conservative treatment fails. We present a rare case of OCD involving the left sacroiliac joint successfully treated by percutaneous computed tomography-guided retrograde drilling and debridement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Targeted Vessel Ablation for More Efficient Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids

Purpose: To report the first clinical experience with targeted vessel ablation during magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) treatment of symptomatic uterine fibroids. Methods: Pretreatment T1-weighted contrast-enhanced magnetic resonance angiography was used to create a detailed map of the uterine arteries and feeding branches to the fibroids. A three-dimensional overlay of the magnetic resonance angiography images was registered on 3D T2-weighted pretreatment imaging data. Treatment was focused primarily on locations where supplying vessels entered the fibroid. Patients were followed 6 months after treatment with a questionnaire to assess symptoms and quality of life (Uterine Fibroid Symptom and Quality of Life) and magnetic resonance imaging to quantify shrinkage of fibroid volumes. Results: In two patients, three fibroids were treated with targeted vessel ablation during MR-HIFU. The treatments resulted in almost total fibroid devascularization with nonperfused volume to total fibroid volume ratios of 84, 68, and 86%, respectively, of treated fibroids. The predicted ablated volumes during MR-HIFU in patients 1 and 2 were 45, 40, and 82 ml, respectively, while the nonperfused volumes determined immediately after treatment were 195, 92, and 190 ml respectively, which is 4.3 (patient 1) and 2.3 (patient 2) times higher than expected based on the thermal dose distribution. Fibroid-related symptoms reduced after treatment, and quality of life improved. Fibroid volume reduction ranged 31-59% at 6 months after treatment. Conclusion: Targeted vessel ablation during MR-HIFU allowed nearly complete fibroid ablation in both patients. This technique may enhance the use of MR-HIFU for fibroid treatment in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Midterm Results after Uterine Artery Embolization Versus MR-Guided High-Intensity Focused Ultrasound Treatment for Symptomatic Uterine Fibroids

Purpose: To compare the rate of reintervention and midterm changes in symptom severity (SS) and Total health-related quality of life (HRQoL) scores after uterine artery embolization (UAE) and magnetic resonance-guided high-intensity focused ultrasound (MR-g HIFU) for symptomatic uterine fibroids. Methods: Eighty women (median age 38.3 years), equally eligible for MR-g HIFU and UAE who underwent one of both treatments between 2002 and 2009 at our institution, were included. The primary end point of the study was defined as the rate of reintervention after both therapies. The secondary outcome was defined as changes in SS and Total HRQoL scores after treatment. SS and Total HRQoL scores before treatment and at midterm follow-up (median 13.3 months) were assessed by the uterine fibroid symptom and quality-of-life questionnaire (UFS-QoL) and compared. Results: The rate of reintervention was significantly lower after UAE than after MR-g HIFU (p = 0.002). After both treatments, SS and Total HRQoL scores improved significantly from baseline to follow-up (UAE: p < 0.001, p < 0.001; MR-g HIFU: p = 0.002, p < 0.001). Total HRQoL scores were significantly higher after UAE than after MR-g HIFU (p = 0.032). Changes in the SS scores did not differ significantly for both treatments (p = 0.061). Conclusion: UAE and MR-g HIFU significantly improved the health-related quality of life of women with symptomatic uterine fibroids. After UAE, the change in Total HRQoL score improvement was significantly better, and a significantly lower rate of reintervention was observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR-Guided High-Intensity Focused Ultrasound: Current Status of an Emerging Technology

The concept of ideal tumor surgery is to remove the neoplastic tissue without damaging adjacent normal structures. High-intensity focused ultrasound (HIFU) was developed in the 1940s as a viable thermal tissue ablation approach. In clinical practice, HIFU has been applied to treat a variety of solid benign and malignant lesions, including pancreas, liver, prostate, and breast carcinomas, soft tissue sarcomas, and uterine fibroids. More recently, magnetic resonance guidance has been applied for treatment monitoring during focused ultrasound procedures (magnetic resonance-guided focused ultrasound, MRgFUS). Intraoperative magnetic resonance imaging provides the best possible tumor extension and dynamic control of energy deposition using real-time magnetic resonance imaging thermometry. We introduce the fundamental principles and clinical indications of the MRgFUS technique; we also report different treatment options and personal outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone-beam Computed Tomography-guided Stereotactic Liver Punctures: A Phantom Study

Purpose: Images from computed tomography (CT), combined with navigation systems, improve the outcomes of local thermal therapies that are dependent on accurate probe placement. Although the usage of CT is desired, its availability for time-consuming radiological interventions is limited. Alternatively, three-dimensional images from C-arm cone-beam CT (CBCT) can be used. The goal of this study was to evaluate the accuracy of navigated CBCT-guided needle punctures, controlled with CT scans. Methods: Five series of five navigated punctures were performed on a nonrigid phantom using a liver specific navigation system and CBCT volumetric dataset for planning and navigation. To mimic targets, five titanium screws were fixed to the phantom. Target positioning accuracy (TPE{sub CBCT}) was computed from control CT scans and divided into lateral and longitudinal components. Additionally, CBCT-CT guidance accuracy was deducted by performing CBCT-to-CT image coregistration and measuring TPE{sub CBCT-CT} from fused datasets. Image coregistration was evaluated using fiducial registration error (FRE{sub CBCT-CT}) and target registration error (TRE{sub CBCT-CT}). Results: Positioning accuracies in lateral directions pertaining to CBCT (TPE{sub CBCT} = 2.1 {+-} 1.0 mm) were found to be better to those achieved from previous study using CT (TPE{sub CT} = 2.3 {+-} 1.3 mm). Image coregistration error was 0.3 {+-} 0.1 mm, resulting in an average TRE of 2.1 {+-} 0.7 mm (N = 5 targets) and average Euclidean TPE{sub CBCT-CT} of 3.1 {+-} 1.3 mm. Conclusions: Stereotactic needle punctures might be planned and performed on volumetric CBCT images and controlled with multidetector CT with positioning accuracy higher or similar to those performed using CT scanners.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accessible or Inaccessible? Diagnostic Efficacy of CT-Guided Core Biopsies of Head and Neck Masses

PurposeTissue sampling of lesions in the head and neck is challenging due to complex regional anatomy and sometimes necessitates open surgical biopsy. However, many patients are poor surgical candidates due to comorbidity. Thus, we evaluated the use of CT guidance for establishing histopathological diagnosis of head and neck masses.MethodsAll consecutive patients (n = 22) who underwent CT-guided core biopsy of head or neck masses between April 2009 and August 2012 were retrospectively reviewed using the departmental CT interventional procedures database. The indication for each biopsy performed was to establish or exclude a diagnosis of neoplasia in patients with suspicious head or neck lesions found on clinical examination or imaging studies. Patients received conscious sedation and 18 G, semiautomated core needle biopsies were performed by experienced neuroradiologists using 16-slice multidetector row CT imaging guidance (Somatom Definition Siemens Medical Solutions, Germany). Histopathology results of each biopsy were analysed.ResultsSixteen of 22 biopsies that were performed (73 %) yielded a pathological diagnosis. Anatomic locations biopsied included: masticator (n = 7), parapharyngeal (n = 3), parotid (n = 3), carotid (n = 3), perivertebral (n = 3), pharyngeal (n = 2), and retropharyngeal (n = 1) spaces. Six biopsies (27 %) were nondiagnostic due to inadequate tissue sampling, particularly small biopsy sample size and failure to biopsy the true sampling site due to extensive necrosis. No major complications were encountered.ConclusionsThe use of CT guidance to perform core biopsies of head and neck masses is an effective means of establishing histopathological diagnosis and reduces the need for diagnostic open surgical biopsy and general anaesthesia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transarterial Fiducial Marker Placement for Image-guided Proton Therapy for Malignant Liver Tumors

PurposeThe aim of this study is to analyze the technical and clinical success rates and safety of transarterial fiducial marker placement for image-guided proton therapy for malignant liver tumors.Methods and MaterialsFifty-five patients underwent this procedure as an interventional treatment. Five patients had 2 tumors, and 4 tumors required 2 markers each, so the total number of procedures was 64. The 60 tumors consisted of 46 hepatocellular carcinomas and 14 liver metastases. Five-mm-long straight microcoils of 0.018 inches in diameter were used as fiducial markers and placed in appropriate positions for each tumor. We assessed the technical and clinical success rates of transarterial fiducial marker placement, as well as the complications associated with it. Technical success was defined as the successful delivery and placement of the fiducial coil, and clinical success was defined as the completion of proton therapy.ResultsAll 64 fiducial coils were successfully installed, so the technical success rate was 100 % (64/64). Fifty-four patients underwent proton therapy without coil migration. In one patient, proton therapy was not performed because of obstructive jaundice due to bile duct invasion by hepatocellular carcinoma. Thus, the clinical success rate was 98 % (54/55). Slight bleeding was observed in one case, but it was stopped immediately and then observed. None of the patients developed hepatic infarctions due to fiducial marker migration.ConclusionTransarterial fiducial marker placement appears to be a useful and safe procedure for proton therapy for malignant liver tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Anatomical, Procedural, and Operator Skill Factors on the Success and Duration of Fluoroscopy-Guided Transjugular Intrahepatic Portosystemic Shunt

PurposeTo assess the impact of anatomical, procedural, and operator skill factors on the success and duration of fluoroscopy-guided transjugular intrahepatic portoystemic shunt following standard operating procedure (SOP).Material and MethodsDuring a 32-month period, 102 patients underwent transjugular intrahepatic portosystemic shunt creation (TIPS) by two interventional radiologists (IR) following our institutional SOP based on fluoroscopy guidance. Both demographic and procedural data were assessed. The duration of the intervention (D{sub Int}) and of the portal vein puncture (D{sub Punct}) was analyzed depending on the skill level of the IR as well as the anatomic or procedural factors.ResultsIn 99 of the 102 patients, successful TIPS without peri-procedural complications was performed. The mean D{sub Int} (IR1: 77 min; IR2: 51 min, P < 0.005) and the mean D{sub Punct} (IR1: 19 min; IR2: 13 min, P < 0.005) were significantly higher in TIPS performed by IR1 (with 2 years of clinical experience performing TIPS, n = 38) than by IR2 (>10 years of clinical experience performing TIPS, n = 61), (P < 0.005 both, Mann–Whitney U test). D{sub Int} showed a higher correlation with D{sub Punct} for IR2 (R{sup 2} = 0.63) than for IR1 (R{sup 2} = 0.13). There was no significant difference in the D{sub Punct} for both IRs with regard to the success of the wedged portography (P = 0.90), diameter of the portal vein (P = 0.60), central right portal vein length (P = 0.49), or liver function (MELD-Score before the TIPS procedure; P = 0.14).ConclusionTIPS following SOP is safe, fast, and reliable. The only significant factor for shorter D{sub Punct} and D{sub Int} was the clinical experience of the IR. Anatomic variability, successful portography, or liver function did not alter the duration or technical success of TIPS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-Session CT-Guided Percutaneous Microwave Ablation of Bilateral Adrenal Gland Hyperplasia Due to Ectopic ACTH Syndrome

Bilateral adrenalectomy is currently the only available treatment for adrenocorticotropic hormone (ACTH)-dependent Cushing’s syndrome (ectopic ACTH syndrome) that is refractory to pharmacologic therapy. We describe two patients with refractory ectopic ACTH syndrome who were treated with CT-guided percutaneous microwave ablation of both hyperplastic adrenal glands in a single session: One was not a surgical candidate, and the other had undergone unsuccessful surgery. Following the procedure, both patients achieved substantial decreases in serum cortisol, symptomatic improvement, and decreased anti-hypertensive medication requirements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility Study on MR-Guided High-Intensity Focused Ultrasound Ablation of Sciatic Nerve in a Swine Model: Preliminary Results

IntroductionSpastic patients often seek neurolysis, the permanent destruction of the sciatic nerve, for better pain management. MRI-guided high-intensity focused ultrasound (MRgHIFU) may serve as a noninvasive alternative to the prevailing, more intrusive techniques. This in vivo acute study is aimed at performing sciatic nerve neurolysis using a clinical MRgHIFU system.MethodsThe HIFU ablation of sciatic nerves was performed in swine (n = 5) using a HIFU system integrated with a 3 T MRI scanner. Acute lesions were confirmed using T1-weighted contrast-enhanced (CE) MRI and histopathology using hematoxylin and eosin staining. The animals were euthanized immediately following post-ablation imaging.ResultsReddening and mild thickening of the nerve and pallor of the adjacent muscle were seen in all animals. The HIFU-treated sections of the nerves displayed nuclear pyknosis of Schwann cells, vascular hyperemia, perineural edema, hyalinization of the collagenous stroma of the nerve, myelin sheet swelling, and loss of axons. Ablations were visible on CE MRI. Non-perfused volume of the lesions (5.8–64.6 cc) linearly correlated with estimated lethal thermal dose volume (4.7–34.2 cc). Skin burn adjacent to the largest ablated zone was observed in the first animal. Bilateral treatment time ranged from 55 to 138 min, and preparation time required 2 h on average.ConclusionThe acute pilot study in swine demonstrated the feasibility of a noninvasive neurolysis of the sciatic nerve using a clinical MRgHIFU system. Results revealed that acute HIFU nerve lesions were detectable on CE MRI, gross pathology, and histology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous CT-Guided Cryoablation as an Alternative Treatment for an Extensive Pelvic Bone Giant Cell Tumor

A giant cell tumor (GCT) is an intermediate grade, locally aggressive neoplasia. Despite advances in surgical and clinical treatments, cases located on the spine and pelvic bones remain a significant challenge. Failure of clinical treatment with denosumab and patient refusal of surgical procedures (hemipelvectomy) led to the use of cryoablation. We report the use of percutaneous CT-guided cryoablation as an alternative treatment, shown to be a minimally invasive, safe, and effective option for a GCT with extensive involvement of the pelvic bones and allowed structural and functional preservation of the involved bones.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Image-Guided Screw Fixation of Bone Lesions in Cancer Patients: Double-Centre Analysis of Outcomes including Local Evolution of the Treated Focus

AimTo review outcomes and local evolution of treated lesions following percutaneous image-guided screw fixation (PIGSF) of pathological/insufficiency fractures (PF/InF) and impeding fractures (ImF) in cancer patients at two tertiary centres.Materials and methodsThirty-two consecutive patients (mean age 67.5 years; range 33–86 years) with a range of tumours and prognoses underwent PIGSF for non/minimally displaced PF/InF and ImF. Screws were placed under CT/fluoroscopy or cone-beam CT guidance, with or without cementoplasty. Clinical outcomes were assessed using a simple 4-point scale (1 = worse; 2 = stable; 3 = improved; 4 = significantly improved). Local evolution was reviewed on most recent follow-up imaging. Technical success, complications, and overall survival were evaluated.ResultsThirty-six lesions were treated with 74 screws mainly in the pelvis and femoral neck (58.2 %); including 47.2 % PF, 13.9 % InF, and 38.9 % ImF. Cementoplasty was performed in 63.9 % of the cases. Technical success was 91.6 %. Hospital stay was ≤3 days; 87.1 % of lesions were improved at 1-month follow-up; three major complications (early screw-impingement radiculopathy; accelerated coxarthrosis; late coxofemoral septic arthritis) and one minor complication were observed. Unfavourable local evolution at imaging occurred in 3/24 lesions (12.5 %) at mean 8.7-month follow-up, including poor consolidation (one case) and screw loosening (two cases, at least 1 symptomatic). There were no cases of secondary fractures.ConclusionsPIGSF is feasible for a wide range of oncologic patients, offering good short-term efficacy, acceptable complication rates, and rapid recovery. Unfavourable local evolution at imaging may be relatively frequent, and requires close clinico-radiological surveillance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Image-Guided Cryoablation of Challenging Mediastinal Lesions Using Large-Volume Hydrodissection: Technical Considerations and Outcomes

ObjectiveThis study was designed to describe the technique of percutaneous image-guided cryoablation with large-volume hydrodissection for the treatment of challenging mediastinal lesions.MethodsBetween March 2014 and June 2015, three patients (mean age 62.7 years) with four neoplastic anterior mediastinal lesions underwent five cryoablation procedures using large-volume hydrodissection. Procedures were performed under general anaesthesia using CT guidance. Lesion characteristics, hydrodissection and cryoablation data, technical success, complications, and clinical outcomes were assessed using retrospective chart review.ResultsLesions (mean size 2.7 cm; range 2–4.3 cm) were in contact with great vessels (n = 13), trachea (n = 3), and mediastinal nerves (n = 6). Hydrodissection was performed intercostally (n = 4), suprasternally (n = 2), transsternally (n = 1), or via the sternoclavicular joint (n = 1) using 1–3 spinal needles over 13.4 (range 7–26) minutes; 450 ml of dilute contrast was injected (range 300–600 ml) and increased mean lesion-collateral structure distance from 1.9 to 7.7 mm. Vulnerable mediastinal nerves were identified in four of five procedures. Technical success was 100 %, with one immediate complication (recurrent laryngeal nerve injury). Mean follow-up period was 15 months. One lesion demonstrated residual disease on restaging PET-CT and was retreated to achieve complete ablation. At last follow-up, two patients remained disease-free, and one patient developed distant disease after 1 year without local recurrence.ConclusionsCryoablation using large-volume hydrodissection is a feasible technique, enabling safe and effective treatment of challenging mediastinal lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Spinal Ablation: A Review

The image-guided thermal ablation procedures can be used to treat a variety of benign and malignant spinal tumours. Small size osteoid osteoma can be treated with laser or radiofrequency. Larger tumours (osteoblastoma, aneurysmal bone cyst and metastasis) can be addressed with radiofrequency or cryoablation. Results on the literature of spinal microwave ablation are scarce, and thus it should be used with caution. A distinct advantage of cryoablation is the ability to monitor the ice-ball by intermittent CT or MRI. The different thermal insulation, temperature and electrophysiological monitoring techniques should be applied. Cautious pre-procedural planning and intermittent intra-procedural monitoring of the ablation zone can help reduce neural complications. Tumour histology, patient clinical-functional status and life-expectancy should define the most efficient and least disabling treatment option.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Resolution of Postural Orthostatic Tachycardia Syndrome After CT-Guided, Percutaneous T2 Ethanol Ablation for Hyperhidrosis

Postural orthostatic tachycardia syndrome is characterized by orthostatic intolerance. Orthostasis (or other mild physical stress) triggers a cascade of inappropriate tachycardia, lightheadedness, palpitations, and often fainting. The underlying defect is sympathetic dysregulation of the heart, which receives its sympathetic tone from the cervical and upper thoracic sympathetic ganglia. Primary hyperhidrosis is also thought to be the result of sympathetic dysregulation. We present the case of a patient treated with CT-guided, percutaneous T2 EtOH sympatholysis for craniofacial hyperhidrosis. The patient also suffered from postural orthostatic tachycardia syndrome for many years and was unresponsive to treatment. Immediately after sympatholysis, the patient experienced resolution of both craniofacial hyperhidrosis and postural orthostatic tachycardia syndrome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MRI-guided Wire Localization Surgical Biopsy in an Adolescent Patient with a Difficult to Diagnose Case of Lymphoma

A 17-year-old previously healthy female presented with a progressive soft tissue infiltrative process involving the neck and thorax. Extensive diagnostic evaluation including multiple imaging, laboratory, and biopsy studies was nondiagnostic. Due to an urgent need to establish a diagnosis and several previous nondiagnostic biopsies, she was referred to interventional radiology for MRI-guided wire localization immediately prior to open surgical biopsy. Under general anesthesia, wires were placed in the areas of increased T2 signal within the bilateral splenius capitis muscles using intermittent MRI-guidance followed by immediate surgical biopsy down to the wires. Pathology confirmed the diagnosis of diffuse large B-cell lymphoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultrasound-Guided Angioplasty of Dysfunctional Vascular Access for Haemodialysis. The Pros and Cons

PurposeTo describe the benefits and the disadvantages of angioplasty in dialysis fistulas using only ultrasound guidance.Materials and MethodsThis is a prospective study in 132 failing or non-maturing arteriovenous accesses that underwent 189 ultrasound-guided balloon angioplasties. The technical success was defined as non-use of X-ray fluoroscopy during the procedure.Results127 procedures (67%) were successfully completed without fluoroscopy. Most failures were due to difficulty to traverse aneurismal segments, as well as anastomotic stenoses. Including initial failures, the primary patency rates at 6, 12 months and 2 years were 75 ± 3, 41 ± 3 and 14 ± 2%, respectively.ConclusionEndovascular repair of the dysfunctional vascular access for haemodialysis under ultrasound guidance is feasible and safe in roughly two-thirds of cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helical-Tip Needle for Transthoracic Percutaneous Image-Guided Biopsy of Lung Tumors: Results of a Pilot Prospective Comparative Study with a Standard Tru-Cut Needle

PurposeTo prospectively evaluate feasibility and diagnostic performance of the 14-gauge helical-tip (Spirotome™, Cook{sup ®} Medical, Bloomington, USA) needle in transthoracic needle biopsy (TTNB) of lung lesions, compared to a conventional 18-gauge Tru-Cut needle.Materials and MethodsStudy was institutional review board approved, with informed consent obtained. Data from synchronous Spirotome and Tru-Cut image-guided TTNB of 20 consecutive patients with malignant peripheral lung tumors larger than 3 cm were enrolled for pathologic characterization and mutational analysis. Samples obtained with Spirotome and Tru-Cut needle were compared for fragmentation, length, weight, morphologic and immunohistochemistry typifying, tumor cellularity (TC) and DNA concentration.ResultsThe technical success rate for TTNB with Spirotome was 100%, and no major complications occurred. Less fragmentation (mean 2 vs. 3 fragments, P = .418), greater weight (mean 13 vs. 8.5 mg, P = .027) and lower length (mean 10.2 vs. 12.6 mm, P = .174) were observed with Spirotome compared to Tru-Cut needle. Accuracy of Spirotome and Tru-Cut needle in defining cancer histotype was similar (90%). Absolute and relative TC (mean 42 vs. 38, 124 vs. 108/10HPF), and DNA concentration (mean 49.6 vs. 39.0 ng/μl) were higher with Spirotome compared to Tru-Cut needle, with no statistical significance (P = .787 and P = .140, respectively).Conclusions Percutaneous 14-gauge Spirotome TTNB of selected lesions is feasible and accurate. It provides adequate samples for diagnosis, comparable to 18-gauge Tru-Cut needle, with a higher amount of tumor tissue (weight, TC, DNA concentration) even in shorter samples.

62 RADIOLOGY AND NUCLEAR MEDICINE↗