Search NASA⌕ Search

SEARCH · Search NASA

Results for “linearity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Evaluation and comparison of an adaptive method technique for improved performance of linear Fresnel secondary designs

As a line-focus concentrating solar power (CSP) technology, linear Fresnel collectors have the potential to become a low-cost solution for electricity production and a variety of thermal energy applications. However, this technology often suffers from relatively low performance. A secondary reflector is a key component used to improve optical performance of a linear Fresnel collector. The shape of a secondary reflector is particularly critical in determining solar power captured by the absorber tube(s), and thus, the collector's optical performance. However, to the authors' knowledge, no well-established process existed to derive the optimal secondary shape prior to the development of a new adaptive method to optimize the secondary reflector shape. The new adaptive method does not assume any pre-defined analytical form; rather, it constitutes an optimum shape through an adaptive process by maximizing the energy collection onto the absorber tube. In this paper, the adaptive method is compared with popular secondary-reflector designs with respect to a collector's optical performance under various scenarios. For the first time, a comprehensive, in-depth comparison was conducted on all popular secondary designs for CSP applications. In conclusion, it is shown that the adaptive design exhibits the best optical performance.

14 SOLAR ENERGY↗

Incremental Interval Assignment by Integer Linear Algebra with Improvements

Interval Assignment (IA) is the problem of selecting the number of mesh edges (intervals) for each curve for conforming quad and hex meshing. The intervals x is fundamentally integer-valued. Many other approaches perform numerical optimization then convert a floating-point solution into an integer solution, which is slow and error prone. We avoid such steps: we start integer, and stay integer. Incremental Interval Assignment (IIA) uses integer linear algebra (Hermite normal form) to find an initial solution to the meshing constraints, satisfying the integer matrix equation Solving for reduced row echelon form provides integer vectors spanning the nullspace of A. Here we add vectors from the nullspace to improve the initial solution, maintaining Ax = b Heuristics find good integer linear combinations of nullspace vectors that provide strict improvement towards variable bounds or goals. IIA always produces an integer solution if one exists. In practice we usually achieve solutions close to the user goals, but there is no guarantee that the solution is optimal, nor even satisfies variable bounds, e.g. has positive intervals. We describe several algorithmic changes since first publication that tend to improve the final solution. The software is freely available.

97 MATHEMATICS AND COMPUTING↗

Fast multiscale contrast independent preconditioners for linear elastic topology optimization problems

The goal of this work is to present a fast and viable approach for the numerical solution of the high-contrast state problems arising in topology optimization. The optimization process is iterative, and the gradients are obtained by an adjoint analysis, which requires the numerical solution of large high-contrast linear elastic problems with features spanning several length scales. The size of the discretized problems forces the utilization of iterative linear solvers with solution time dependent on the quality of the preconditioner. The lack of clear separation between the scales, as well as the high-contrast, imposes severe challenges on the standard preconditioning techniques. Thus, here we propose new methods for the high-contrast elasticity equation with performance independent of the high-contrast and the multi-scale structure of the elasticity problem. The solvers are based on two-levels domain decomposition techniques with a carefully constructed coarse level to deal with the high-contrast and multi-scale nature of the problem. The construction utilizes spectral equivalence between scalar diffusion and each displacement block of the elasticity problems and, in contrast to previous solutions proposed in the literature, is able to select the appropriate dimension of the coarse space automatically. The new methods inherit the advantages of domain decomposition techniques, such as easy parallelization and scalability. Finally, the presented numerical experiments demonstrate the excellent performance of the proposed methods.

97 MATHEMATICS AND COMPUTING↗

A coupling approach for linear elasticity problems with spatially non-coincident discretized interfaces

Here we present a new method for coupled linear elasticity problems whose finite element discretization may lead to spatially non-coincident discretized interfaces. Our approach combines the classical Dirichlet–Neumann coupling formulation with a new set of discretized interface conditions obtained through Taylor series expansions. We show that these conditions ensure linear consistency of the coupled finite element solution. We then formulate an iterative solution method for the coupled discrete system and apply the new coupling approach to two representative settings for which we also provide several numerical illustrations. The first setting is a mesh-tying problem in which both coupled structures have the same Lamé parameters whereas the second setting is an interface problem for which the Lamé parameters in the two coupled structures are different.

97 MATHEMATICS AND COMPUTING↗

Scalable Preconditioning of Block-Structured Linear Algebra Systems using ADMM

In this paper, we study the solution of block-structured linear algebra systems arising in optimization by using iterative solution techniques. These systems are the core computational bottleneck of many problems of interest such as parameter estimation, optimal control, network optimization, and stochastic programming. Our approach uses a Krylov solver (GMRES) that is preconditioned with an alternating method of multipliers (ADMM). We show that this ADMM-GMRES approach overcomes well-known scalability issues of Schur complement decomposition in problems that exhibit a high degree of coupling. The effectiveness of the approach is demonstrated using linear systems that arise in stochastic optimal power flow problems and that contain up to 2 million total variables and 4,000 coupling variables. We find that ADMM-GMRES is nearly an order of magnitude faster than Schur complement decomposition. Moreover, we demonstrate that the approach is robust to the selection of the augmented Lagrangian penalty parameter, which is a key advantage over the direct use of ADMM.

97 MATHEMATICS AND COMPUTING↗

Massively parallel and linear-scaling algorithm for second-order Moller–Plesset perturbation theory applied to the study of supramolecular wires

Here, we present a scalable cross-platform hybrid MPI/OpenMP/OpenACC implementation of the Divide–Expand–Consolidate (DEC) formalism with portable performance on heterogeneous HPC architectures. The Divide–Expand–Consolidate formalism is designed to reduce the steep computational scaling of conventional many-body methods employed in electronic structure theory to linear scaling, while providing a simple mechanism for controlling the error introduced by this approximation. Our massively parallel implementation of this general scheme has three levels of parallelism, being a hybrid of the loosely coupled task-based parallelization approach and the conventional MPI +X programming model, where X is either OpenMP or OpenACC. We demonstrate strong and weak scalability of this implementation on heterogeneous HPC systems, namely on the GPU-based Cray XK7 Titan supercomputer at the Oak Ridge National Laboratory. Using the “resolution of the identity second-order Moller–Plesset perturbation theory” (RI-MP2) as the physical model for simulating correlated electron motion, the linear-scaling DEC implementation is applied to 1-aza-adamantane-trione (AAT) supramolecular wires containing up to 40 monomers (2440 atoms, 6800 correlated electrons, 24 440 basis functions and 91 280 auxiliary functions). This represents the largest molecular system treated at the MP2 level of theory, demonstrating an efficient removal of the scaling wall pertinent to conventional quantum many-body methods.

97 MATHEMATICS AND COMPUTING↗

Disjunctive linear separation conditions and mixed-integer formulations for aircraft conflict resolution

In this paper, we address the aircraft conflict resolution problem in air traffic control. We introduce new mixed-integer programming formulations for aircraft conflict resolution with speed, heading and altitude control which are based on disjunctive linear separation conditions. We first examine the two-dimensional aircraft conflict resolution problem with speed and heading control represented as continuous decision variables. We show that the proposed disjunctive linear separation conditions are equivalent to the classical nonlinear conditions for aircraft separation. Further, we characterise conflict-free trajectories based on aircraft velocity bounds and propose a simple pre-processing algorithm to identify aircraft pairs which are either always conflict-free, or which cannot be separated using speed and heading control only. We then incorporate altitude control and propose a lexicographic optimisation formulation that aims to minimise the number of flight level changes before resolving outstanding conflicts via two-dimensional velocity control. The proposed mixed-integer programming formulations are nonconvex, and we propose convex relaxations, decomposition methods and constraint generation algorithms to solve the two-dimensional and lexicographic optimisation formulations to guaranteed optimality. Numerical experiments on four types of conflict resolution benchmarking instances are conducted to test the performance of the proposed mixed-integer formulations. Further, the proposed method is compared against two benchmarks based on state-of-the-art approaches for the aircraft conflict resolution problem. Our numerical results show that the proposed method largely outperforms both benchmarks in terms of runtime and is able to solve significantly more instances to global optimality.

97 MATHEMATICS AND COMPUTING↗

Solution of the linear wave-particle kinetic equation for global modes of arbitrary frequency in a tokamak

The linear response of a plasma to perturbations of arbitrary frequency and wavelength is derived for any axisymmetric magnetized toroidal plasma. An explicit transformation to action-angle coordinates is achieved using orthogonal magnetic coordinates and the Littlejohn Lagrangian, establishing the validity of this result to arbitrary order in normalized Larmor radius. The global resonance condition for compressional modes is clarified in more detail than in previous works, confirming that the poloidal orbit-average of the cyclotron frequency gives the desired result at lowest order in Larmor radius. The global plasma response to the perturbation at each resonance is captured by a poloidal and gyroaverage of the perturbing potential. A “global gyroaveraging” of the potential is a natural by-product of this analysis which takes into account the changing of the magnetic field over an orbit. The resonance condition depends on two arbitrary integers which completely separately capture the effects poloidal non-uniformity and finite Larmor radius in generating sidebands. We learn that poloidal sidebands generated for compressional modes are dominated by the change in gyrofrequency over the orbit, which is very different to shear modes where the gyrofrequency only contributes via a finite Larmor radius effect. This increases the number of bounce harmonics required to compute the linear drive, giving a more complicated resonance map. An example calculation is given comparing resonance of shear and compressional modes in a published DIII-D case.

Compressional↗

Preliminary Experience in Treatment of Papillary and Macular Retinoblastoma: Evaluation of Local Control and Local Complications After Treatment With Linear Accelerator-Based Stereotactic Radiotherapy With Micromultileaf Collimator as Second-Line or Salvage Treatment After Chemotherapy

Purpose: To determine the local control and complication rates for children with papillary and/or macular retinoblastoma progressing after chemotherapy and undergoing stereotactic radiotherapy (SRT) with a micromultileaf collimator. Methods and Materials: Between 2004 and 2008, 11 children (15 eyes) with macular and/or papillary retinoblastoma were treated with SRT. The mean age was 19 months (range, 2-111). Of the 15 eyes, 7, 6, and 2 were classified as International Classification of Intraocular Retinoblastoma Group B, C, and E, respectively. The delivered dose of SRT was 50.4 Gy in 28 fractions using a dedicated micromultileaf collimator linear accelerator. Results: The median follow-up was 20 months (range, 13-39). Local control was achieved in 13 eyes (87%). The actuarial 1- and 2-year local control rates were both 82%. SRT was well tolerated. Late adverse events were reported in 4 patients. Of the 4 patients, 2 had developed focal microangiopathy 20 months after SRT; 1 had developed a transient recurrence of retinal detachment; and 1 had developed bilateral cataracts. No optic neuropathy was observed. Conclusions: Linear accelerator-based SRT for papillary and/or macular retinoblastoma in children resulted in excellent tumor control rates with acceptable toxicity. Additional research regarding SRT and its intrinsic organ-at-risk sparing capability is justified in the framework of prospective trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Megavoltage Image-Based Dynamic Multileaf Collimator Tracking of a NiTi Stent in Porcine Lungs on a Linear Accelerator

Purpose: To investigate the accuracy and potential limitations of MV image-based dynamic multileaf collimator (DMLC) tracking in a porcine model on a linear accelerator. Methods and Materials: A thermo-expandable NiTi stent designed for kilovoltage (kV) X-ray visualization of lung lesions was inserted into the bronchia of three anaesthetized Goettingen minipigs. A four-dimensional computed tomography scan was used for planning a five-field conformal treatment with circular multileaf collimator (MLC) apertures. A 22.5 Gy single fraction treatment was delivered to the pigs. The peak-to-peak stent motion was 3 to 8 mm, with breathing periods of 1.2 to 4 s. Before treatment, X-ray images were used for image-guided setup based on the stent. During treatment delivery, continuous megavoltage (MV) portal images were acquired at 7.5 Hz. The stent was segmented in the images and used for continuous adaptation of the MLC aperture. Offline, the tracking error in beam's eye view of the treatment beam was calculated for each MV image as the difference between the MLC aperture center and the segmented stent position. The standard deviations of the systematic error {Sigma} and the random error {sigma} were determined and compared with the would-be errors for a nontracking treatment with pretreatment image-guided setup. Results: Reliable stent segmentation was obtained for 11 of 15 fields. Segmentation failures occurred when image contrast was dominated by overlapping anatomical structures (ribs, diaphragm) rather than by the stent, which was designed for kV rather than MV X-ray visibility. For the 11 fields with reliable segmentation, {Sigma} was 0.5 mm/0.4 mm in the two imager directions, whereas {sigma} was 0.5 mm/1.1 mm. Without tracking, {Sigma} and {sigma} would have been 1.7 mm/1.4 mm and 0.8 mm/1.4 mm, respectively. Conclusion: For the first time, in vivo DMLC tracking has been demonstrated on a linear accelerator showing the potential for improved targeting accuracy. The study mimicked the envisioned patient workflow of future patient treatments. Clinical implementation of MV image-based tracking would require markers designed for MV visibility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Challenges in Linear Accelerator Radiotherapy for Chordomas and Chondrosarcomas of the Skull Base: Focus on Complications

Purpose: Intracranial chordomas and chondrosarcomas are histologically low-grade, locally invasive tumors that infiltrate the skull base. Currently, consensus therapy includes surgical resection and adjuvant radiotherapy. Radiation delivery is typically limited by the proximity of these tumors to critical skull base structures. Methods: This is a retrospective review of 13 cases of chordomas and 2 cases of chondroid chondrosarcomas of the skull based treated with linear accelerator stereotactic radiotherapy (SRT, n = 10) or stereotactic radiosurgery (SRS, n = 5). The average time to the most recent follow-up visit was 4.5 years. The tumor characteristics, treatment details, and outcomes were recorded. Each radiation plan was reviewed, and the dosage received by the brainstem, optic apparatus, and pituitary was calculated. Results: Of the 10 patients treated with SRT, 6 were found to have unchanged or decreased tumor size as determined from radiographic follow-up. Of the 5 patients treated with SRS, 3 were found to have stable or unchanged tumors at follow-up. The complications included 1 SRT patient who developed endocrinopathy, 2 patients (1 treated with SRS and the other with SRT), who developed cranial neuropathy, and 1 SRS patient who developed visual deficits. Additionally, 1 patient who received both SRS and SRT within 2 years for recurrence experienced transient medial temporal lobe radiation changes that resolved. Conclusions: Where proton beam therapy is unavailable, linear accelerator-based SRT or radiosurgery remains a safe option for adjuvant therapy of chordomas and chondrosarcomas of the skull base. The exposure of the optic apparatus, pituitary stalk, and brainstem must be considered during planning to minimize complications. If the optic apparatus is included in the 80% isodose line, it might be best to fractionate therapy. Exposure of the pituitary stalk should be kept to <30 Gy to minimize endocrine dysfunction. Brainstem exposure should be limited to <60 Gy in fractions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional, Time-Resolved, Intrafraction Motion Monitoring Throughout Stereotactic Liver Radiation Therapy on a Conventional Linear Accelerator

Purpose: To investigate the time-resolved 3-dimensional (3D) internal motion throughout stereotactic body radiation therapy (SBRT) of tumors in the liver using standard x-ray imagers of a conventional linear accelerator. Methods and Materials: Ten patients with implanted gold markers received 11 treatment courses of 3-fraction SBRT in a stereotactic body-frame on a conventional linear accelerator. Two pretreatment and 1 posttreatment cone-beam computed tomography (CBCT) scans were acquired during each fraction. The CBCT projection images were used to estimate the internal 3D marker motion during CBCT acquisition with 11-Hz resolution by a monoscopic probability-based method. Throughout the treatment delivery by conformal or volumetric modulated arc fields, simultaneous MV portal imaging (8 Hz) and orthogonal kV imaging (5 Hz) were applied to determine the 3D marker motion using either MV/kV triangulation or the monoscopic method when marker segmentation was unachievable in either MV or kV images. The accuracy of monoscopic motion estimation was quantified by also applying monoscopic estimation as a test for all treatments during which MV/kV triangulation was possible. Results: Root-mean-square deviations between monoscopic estimations and triangulations were less than 1.0 mm. The mean 3D intrafraction and intrafield motion ranges during liver SBRT were 17.6 mm (range, 5.6-39.5 mm) and 11.3 mm (2.1-35.5mm), respectively. The risk of large intrafraction baseline shifts correlated with intrafield respiratory motion range. The mean 3D intrafractional marker displacement relative to the first CBCT was 3.4 mm (range, 0.7-14.5 mm). The 3D displacements exceeded 8.8 mm 10% of the time. Conclusions: Highly detailed time-resolved internal 3D motion was determined throughout liver SBRT using standard imaging equipment. Considerable intrafraction motion was observed. The demonstrated methods provide a widely available approach for motion monitoring that, combined with motion-adaptive treatment techniques, has the potential to improve the accuracy of radiation therapy for moving targets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intraoperative Radiation Therapy in Early Breast Cancer Using a Linear Accelerator Outside of the Operative Suite: An “Image-Guided” Approach

Purpose: To present local control, complications, and cosmetic outcomes of intraoperative radiation therapy (IORT) for early breast cancer, as well as technical aspects related to the use of a nondedicated linear accelerator. Methods and Materials: This prospective trial began in May of 2004. Eligibility criteria were biopsy-proven breast-infiltrating ductal carcinoma, age >40 years, tumor <3 cm, and cN0. Exclusion criteria were in situ or lobular types, multicentricity, skin invasion, any contraindication for surgery and/or radiation therapy, sentinel lymph node involvement, metastasis, or another malignancy. Patients underwent classic quadrantectomy with intraoperative sentinel lymph node and margins evaluation. If both free, the patient was transferred from operative suite to linear accelerator room, and IORT was delivered (21 Gy). Primary endpoint: local recurrence (LR); secondary endpoints: toxicities and aesthetics. Quality assurance involved using a customized shield for chest wall protection, applying procedures to minimize infection caused by patient transportation, and using portal films to check collimator-shield alignment. Results: A total of 152 patients were included, with at least 1 year follow-up. Median age (range) was 58.3 (40-85.4) years, and median follow-up time was 50.7 (12-110.5) months. The likelihood of 5-year local recurrence was 3.7%. There were 3 deaths, 2 of which were cancer related. The Kaplan-Meier 5-year actuarial estimates of overall, disease-free, and local recurrence-free survivals were 97.8%, 92.5%, and 96.3%, respectively. The overall incidences of acute and late toxicities were 12.5% and 29.6%, respectively. Excellent, good, fair, and bad cosmetic results were observed in 76.9%, 15.8%, 4.3%, and 2.8% of patients, respectively. Most treatments were performed with a 5-cm collimator, and in 39.8% of the patients the electron-beam energy used was ≥12 MeV. All patients underwent portal film evaluation, and the shielding was repositioned in 39.9% of cases. No infection or anesthesia complications were observed. Conclusions: Local control with IORT was adequate, with low complication rates and good cosmetic outcomes. More than one-third of patients benefited from the “image-guidance” approach, and almost 40% benefited from the option of higher electron beam energies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anderson acceleration of the Jacobi iterative method: An efficient alternative to Krylov methods for large, sparse linear systems

We employ Anderson extrapolation to accelerate the classical Jacobi iterative method for large, sparse linear systems. Specifically, we utilize extrapolation at periodic intervals within the Jacobi iteration to develop the Alternating Anderson–Jacobi (AAJ) method. We verify the accuracy and efficacy of AAJ in a range of test cases, including nonsymmetric systems of equations. We demonstrate that AAJ possesses a favorable scaling with system size that is accompanied by a small prefactor, even in the absence of a preconditioner. In particular, we show that AAJ is able to accelerate the classical Jacobi iteration by over four orders of magnitude, with speed-ups that increase as the system gets larger. Moreover, we find that AAJ significantly outperforms the Generalized Minimal Residual (GMRES) method in the range of problems considered here, with the relative performance again improving with size of the system. As a result, the proposed method represents a simple yet efficient technique that is particularly attractive for large-scale parallel solutions of linear systems of equations.

97 MATHEMATICS AND COMPUTING↗

Application of linear multifrequency-grey acceleration to preconditioned Krylov iterations for thermal radiation transport

The thermal radiative transfer (TRT) equations comprise a radiation equation coupled to the material internal energy equation. Linearization of these equations produces effective, thermally-redistributed scattering through absorption-reemission. In this paper, we investigate the effectiveness and efficiency of Linear-Multi-Frequency-Grey (LMFG) acceleration that has been reformulated for use as a preconditioner to Krylov iterative solution methods. We introduce two general frameworks, the scalar flux formulation (SFF) and the absorption rate formulation (ARF), and investigate their iterative properties in the absence and presence of true scattering. SFF has a group-dependent state size but may be formulated without inner iterations in the presence of scattering, while ARF has a group-independent state size but requires inner iterations when scattering is present. We compare and evaluate the computational cost and efficiency of LMFG applied to these two formulations using a direct solver for the preconditioners. Finally, this work is novel because the use of LMFG for the radiation transport equation, in conjunction with Krylov methods, involves special considerations not required for radiation diffusion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A linearity preserving nodal variation limiting algorithm for continuous Galerkin discretization of ideal MHD equations

A stabilized continuous Galerkin (CG) method for magnetohydrodynamics (MHD) is presented herein. Ideal, compressible inviscid MHD equations are discretized in space on unstructured meshes using piecewise linear or bilinear finite element bases to get a semi-discrete scheme. Stabilization is then introduced to the semi-discrete method in a strategy that follows the algebraic flux correction paradigm. This involves adding some artificial diffusion to the high order, semi-discrete method and mass lumping in the time derivative term. The result is a low order method that provides local extremum diminishing properties for hyperbolic systems. The difference between the low order method and the high order method is scaled element-wise using a limiter and added to the low order scheme. The limiter is solution dependent and computed via an iterative linearity preserving nodal variation limiting strategy. The stabilization also involves an optional consistent background high order dissipation that reduces phase errors. The resulting stabilized scheme is a semi-discrete method that can be applied to inviscid shock MHD problems and may be even extended to resistive and viscous MHD problems. To satisfy the divergence free constraint of the MHD equations, we add parabolic divergence cleaning to the system. Various time integration methods can be used to discretize the scheme in time. We demonstrate the robustness of the scheme by solving several shock MHD problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RandONets: Shallow networks with random projections for learning linear and nonlinear operators

Deep neural networks have been extensively used for the solution of both the forward and the inverse problem for dynamical systems. However, their implementation necessitates optimizing a high-dimensional space of parameters and hyperparameters. This fact, along with the requirement of substantial computational resources, pose a barrier to achieving high numerical accuracy, but also interpretability. Here, to address the above challenges, we present Random Projection-based Operator Networks (RandONets): shallow networks with random projections and tailor-made numerical analysis methods that learn accurately and fast linear and nonlinear operators. Building on previous works, we prove that RandOnets are universal approximators of linear and nonlinear operators. Due to their simplicity, RandONets provide a one-step transformation of the input space, facilitating interpretability. For the evaluation of their performance, we focus on operators of PDEs. We show, that RandONets outperform by several orders of magnitude, both in terms of numerical approximation accuracy and computational cost, the “vanilla” DeepONets. Hence, we believe that our method will trigger further developments in the field of scientific machine learning, for the development of new ‘’light”schemes that will provide high accuracy while reducing dramatically the computational cost. A MATLAB toolbox for RandONets, including demos, is available on GitHub at https://github.com/GianlucaFabiani/RandONets.

Interpretable machine learning↗

Online Kidney Position Verification Using Non-Contrast Radiographs on a Linear Accelerator with on Board KV X-Ray Imaging Capability

The kidneys are dose-limiting organs in abdominal radiotherapy. Kilovoltage (kV) radiographs can be acquired using on-board imager (OBI)-equipped linear accelerators with better soft tissue contrast and lower radiation doses than conventional portal imaging. A feasibility study was conducted to test the suitability of anterior-posterior (AP) non-contrast kV radiographs acquired at treatment time for online kidney position verification. Anthropomorphic phantoms were used to evaluate image quality and radiation dose. Institutional Review Board approval was given for a pilot study that enrolled 5 adults and 5 children. Customized digitally reconstructed radiographs (DRRs) were generated to provide a priori information on kidney shape and position. Radiotherapy treatment staff performed online evaluation of kidney visibility on OBI radiographs. Kidney dose measured in a pediatric anthropomorphic phantom was 0.1 cGy for kV imaging and 1.7 cGy for MV imaging. Kidneys were rated as well visualized in 60% of patients (90% confidence interval, 34-81%). The likelihood of visualization appears to be influenced by the relative AP separation of the abdomen and kidneys, the axial profile of the kidneys, and their relative contrast with surrounding structures. Online verification of kidney position using AP non-contrast kV radiographs on an OBI-equipped linear accelerator appears feasible for patients with suitable abdominal anatomy. Kidney position information provided is limited to 2-dimensional 'snapshots,' but this is adequate in some clinical situations and potentially advantageous in respiratory-correlated treatments. Successful clinical implementation requires customized partial DRRs, appropriate imaging parameters, and credentialing of treatment staff.

61 RADIATION PROTECTION AND DOSIMETRY↗