Search NASA⌕ Search

SEARCH · Search NASA

Results for “module performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Improved constraints on inelastic dark matter

We perform an extensive study of the DAMA annual modulation data in the context of inelastic dark matter. We find that inelastic dark matter with mass m{sub χ}∼>15 GeV is excluded at the 95% confidence level by the combination of DAMA spectral information and results from other direct detection experiments. However, at smaller m{sub χ}, inelastic dark matter constitutes a possible solution to the DAMA puzzle.

79 ASTRONOMY AND ASTROPHYSICS↗

Continuous-variable quantum computation with spatial degrees of freedom of photons

We discuss the use of the transverse spatial degrees of freedom of photons propagating in the paraxial approximation for continuous-variable information processing. Given the wide variety of linear optical devices available, a diverse range of operations can be performed on the spatial degrees of freedom of single photons. Here we show how to implement a set of continuous quantum logic gates which allow for universal quantum computation. In contrast with the usual quadratures of the electromagnetic field, the entire set of single-photon gates for spatial degrees of freedom does not require optical nonlinearity and, in principle, can be performed with a single device: the spatial light modulator. Nevertheless, nonlinear optical processes, such as four-wave mixing, are needed in the implementation of two-photon gates. The efficiency of these gates is at present very low; however, small-scale investigations of continuous-variable quantum computation are within the reach of current technology. In this regard, we show how novel cluster states for one-way quantum computing can be produced using spontaneous parametric down-conversion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantification of a Minimum Detectable Soiling Level to Affect Photovoltaic Devices by Natural and Simulated Soils

Here, we report that soil accumulation on photovoltaic (PV) modules presents a challenge to long-term performance prediction and lifetime estimates due to the inherent difficulty in quantifying small changes over an extended period. Low mass loadings of soil are a common occurrence but remain difficult to quantify. In order to more accurately describe the specific effects of sparse soil films on PV systems, we have expanded upon an earlier technique to measure the optical losses due to an artificially applied obscurant film. A synthetic soil analog was sprayed onto glass coupons at very brief intervals with a high-volume, low-pressure pneumatic sprayer. Light transmission through the grime film was evaluated using a quantum efficiency test stand and UV/vis spectroscopy. A 0.1-g/m 2 grime loading was determined to be the limit of mass measurement sensitivity, which is similar to some reports of daily soil accumulation. Predictable, linear decreases in transmission were observed for samples with a mass loading between 0.1 and 0.5 g/m 2 . A similar change was observed for soiled coupons from an outdoor monitoring station. Collected soil from the field coupons was analyzed to develop a compositional analog for indoor studies. Lastly, natural and synthetic soils produced similar decreases in transmission.

14 SOLAR ENERGY↗

Arrhenius Analysis of the Degradation Modes in Emerging Photovoltaic Backsheets

With increasingly large-scale deployments of photovoltaic (PV) modules to meet global energy demands, interest in better establishing modules' lifespans is growing. We report on the performance of co-extruded polyolefin- (PO)-based backsheets as environmentally friendly alternatives to fluoropolymer-reinforced polyethylene-terephthalate (PET)-based backsheets using three hygrometric accelerated test conditions. After completing cumulative 4000 hours of aging, we analyzed data from electrical performance (I-V), surface roughness (gloss), and appearance (L, a*, b* color) characterizations to quantify degradation rates, quantify the corresponding activation energy, and cross-correlate between the characteristics examined, thereby providing insights into the relationship between physical characteristics and operating performance.

BackFLIP↗

Estimation of three-dimensional intrinsic dosimetric uncertainties resulting from using deformable image registration for dose mapping

Purpose: This article presents a general procedural framework to assess the point-by-point precision in mapped dose associated with the intrinsic uncertainty of a deformable image registration (DIR) for any arbitrary patient. Methods: Dose uncertainty is obtained via a three-step process. In the first step, for each voxel in an imaging pair, a cluster of points is obtained by an iterative DIR procedure. In the second step, the dispersion of the points due to the imprecision of the DIR method is used to compute the spatial uncertainty. Two different ways to quantify the spatial uncertainty are presented in this work. Method A consists of a one-dimensional analysis of the modules of the position vectors, whereas method B performs a more detailed 3D analysis of the coordinates of the points. In the third step, the resulting spatial uncertainty estimates are used in combination with the mapped dose distribution to compute the point-by-point dose standard deviation. The process is demonstrated to estimate the dose uncertainty induced by mapping a 62.6 Gy dose delivered on maximum exhale to maximum inhale of a ten-phase four-dimensional lung CT. Results: For the demonstration lung image pair, the standard deviation of inconsistency vectors is found to be up to 9.2 mm with a mean {sigma} of 1.3 mm. This uncertainty results in a maximum estimated dose uncertainty of 29.65 Gy if method A is used and 21.81 Gy for method B. The calculated volume with dose uncertainty above 10.00 Gy is 602 cm{sup 3} for method A and 1422 cm{sup 3} for method B. Conclusions: This procedure represents a useful tool to evaluate the precision of a mapped dose distribution due to the intrinsic DIR uncertainty in a patient. The procedure is flexible, allowing incorporation of alternative intrinsic error models.

60 APPLIED LIFE SCIENCES↗

The emergence of nonuniform spatiotemporal fractionation schemes within the standard BED model

Purpose: Nonuniform spatiotemporal radiotherapy fractionation schemes, i.e., delivering distinct dose distributions in different fractions can potentially improve the therapeutic ratio. This is possible if the dose distributions are designed such that similar doses are delivered to normal tissues (exploit the fractionation effect) while hypofractionating subregions of the tumor. In this paper, the authors develop methodology for treatment planning with nonuniform fractions and demonstrate this concept in the context of intensity-modulated proton therapy (IMPT). Methods: Treatment planning is performed by simultaneously optimizing (possibly distinct) IMPT dose distributions for multiple fractions. This is achieved using objective and constraint functions evaluated for the cumulative biologically equivalent dose (BED) delivered at the end of treatment. BED based treatment planning formulations lead to nonconvex optimization problems, such that local gradient based algorithms require adequate starting positions to find good local optima. To that end, the authors develop a combinatorial algorithm to initialize the pencil beam intensities. Results: The concept of nonuniform spatiotemporal fractionation schemes is demonstrated for a spinal metastasis patient treated in two fractions using stereotactic body radiation therapy. The patient is treated with posterior oblique beams with the kidneys being located in the entrance region of the beam. It is shown that a nonuniform fractionation scheme that hypofractionates the central part of the tumor allows for a skin and kidney BED reduction of approximately 10%–20%. Conclusions: Nonuniform spatiotemporal fractionation schemes represent a novel approach to exploit fractionation effects that deserves further exploration for selected disease sites.

60 APPLIED LIFE SCIENCES↗

Detector dose response in megavoltage small photon beams. II. Pencil beam perturbation effects

Purpose: To quantify detector perturbation effects in megavoltage small photon fields and support the theoretical explanation on the nature of quality correction factors in these conditions. Methods: In this second paper, a modern approach to radiation dosimetry is defined for any detector and applied to small photon fields. Fano’s theorem is adapted in the form of a cavity theory and applied in the context of nonstandard beams to express four main effects in the form of perturbation factors. The pencil-beam decomposition method is detailed and adapted to the calculation of perturbation factors and quality correction factors. The approach defines a perturbation function which, for a given field size or beam modulation, entirely determines these dosimetric factors. Monte Carlo calculations are performed in different cavity sizes for different detection materials, electron densities, and extracameral components. Results: Perturbation effects are detailed with calculated perturbation functions, showing the relative magnitude of the effects as well as the geometrical extent to which collimating or modulating the beam impacts the dosimetric factors. The existence of a perturbation zone around the detector cavity is demonstrated and the approach is discussed and linked to previous approaches in the literature to determine critical field sizes. Conclusions: Monte Carlo simulations are valuable to describe pencil beam perturbation effects and detail the nature of dosimetric factors in megavoltage small photon fields. In practice, it is shown that dosimetric factors could be avoided if the field size remains larger than the detector perturbation zone. However, given a detector and beam quality, a full account for the detector geometry is necessary to determine critical field sizes.

07 ISOTOPE AND RADIATION SOURCES↗

Effect of the ultrasonic frequency on the multiple X-ray scattering from a LiNbO{sub 3} crystal modulated by a surface acoustic wave

The effect of multiple scattering on the formation of the {theta}-2{theta} scan curves for a crystal modulated by a surface acoustic wave (SAW), depending on the ultrasonic frequency, has been investigated in the frame-work of the dynamical theory of X-ray diffraction. A model of a Rayleigh surface wave has been analyzed as applied to X-ray diffraction with allowance for the transverse and longitudinal elastic lattice strains. Using the example of the 127 Degree-Sign Y Prime cut of the LiNbO{sub 3} crystal, it is established that the effects of multiple scattering can be neglected for ultrasonic frequencies above 650 MHz; this finding significantly simplifies the numerical calculations of X-ray diffraction from a crystal modulated by a short-wavelength SAW. A comparative quantitative analysis of the experimental data on synchrotron scattering from the 127 Degree-Sign Y Prime cut of a LiNbO{sub 3} crystal modulated by a 952-MHz SAW have been performed, both taking into account and neglecting the effects of multiple scattering. It is shown that the computation time can be reduced by 2 to 3 orders of magnitude.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling Rate Dependent Volume Change in Porous Electrodes in Lithium-Ion Batteries

Automotive manufacturers are working to improve individual cell, module, and overall pack design by increasing the performance, range, and durability, while reducing cost. One key piece to consider during the design process is the active material volume change, its linkage to the particle, electrode, and cell level volume changes, and the interplay with structural components in the rechargeable energy storage system. As the time from initial design to manufacture of electric vehicles decreases, design work needs to move to the virtual domain; therefore, a need for coupled electrochemical-mechanical models that take into account the active material volume change and the rate dependence of this volume change need to be considered. In this study, we illustrated the applicability of a coupled electrochemical-mechanical battery model considering multiple representative particles to capture experimentally measured rate dependent reversible volume change at the cell level through the use of an electrochemical-mechanical battery model that couples the particle, electrode, and cell level volume changes. By employing this coupled approach, the importance of considering multiple active material particle sizes representative of the distribution is demonstrated. The non-uniformity in utilization between two different size particles as well as the significant spatial non-uniformity in the radial direction of the larger particles is the primary driver of the rate dependent characteristics of the volume change at the electrode and cell level.

Electrochemistry↗

Custom ORIGEN Libraries for Tritium Production in Discrete Burnable Absorbers

The ORIGEN module in SCALE is a common method of performing quick depletion and irradiation calculations of various materials in light-water reactors. However, these analyses depend on the neutron spectra in the ARP libraries being accurate for the situation presented. When using insertable burnable absorbers in a LWR with Li-6 in order to produce tritium, the neutron spectrum is highly different than those in the default libraries in ORIGEN, which leads to significant mispredictions in tritium production. Therefore, custom libraries are required, and when comparing to lattice physics codes (CASMO5 and WIMS10) with ORIGEN, using custom libraries is much more accurate than using the default libraries.

Ivanusa, Pavlo↗

A Polyhedral Transformation Framework for Compiler Optimization (Final Project Report)

The project developed the polyhedral compiler transformation module PolyOpt/Fortran in the ROSE compiler framework. PolyOpt/Fortran performs automated transformation of affine loop nests within FORTRAN programs for enhanced data locality and parallel execution. A FORTAN version of the Polybench library was also developed by the project. A third development was a dynamic analysis approach to gauge vectorization potential within loops of programs; software (DDVec) for automated instrumentation and dynamic analysis of programs was developed.

97 MATHEMATICS AND COMPUTING↗

A 200 C Universal Gate Driver Integrated Circuit for Extreme Environment Applications

High-temperature power converters (dc-dc, dc-ac, etc.) have enormous potential in extreme environment applications, including automotive, aerospace, geothermal, nuclear, and well logging. For successful realization of such high-temperature power conversion modules, the associated control electronics also need to perform at high temperature. This paper presents a silicon-on-insulator (SOI) based high-temperature gate driver integrated circuit (IC) incorporating an on-chip low-power temperature sensor and demonstrating an improved peak output current drive over our previously reported work. This driver IC has been primarily designed for automotive applications, where the underhood temperature can reach 200 C. This new gate driver prototype has been designed and implemented in a 0.8 {micro}m, 2-poly, and 3-metal bipolar CMOS-DMOS (Double-Diffused Metal-Oxide Semiconductor) on SOI process and has been successfully tested for up to 200 C ambient temperature driving a SiC MOSFET and a SiC normally-ON JFET. The salient feature of the proposed universal gate driver is its ability to drive power switches over a wide range of gate turn-ON voltages such as MOSFET (0 to 20 V), normally-OFF JFET (-7 to 3 V), and normally-ON JFET (-20 to 0 V). The measured peak output current capability of the driver is around 5 A and is thus capable of driving several power switches connected in parallel. An ultralow-power on-chip temperature supervisory circuit has also been integrated into the die to safeguard the driver circuit against excessive die temperature ({ge}220 C). This approach utilizes increased diode leakage current at higher temperature to monitor the die temperature. The power consumption of the proposed temperature sensor circuit is below 10 {micro}W for operating temperature up to 200 C.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development of Membrane Distillation Technology Utilizing Waste Heat for Treatment of High Salinity Wastewaters

Membrane distillation (MD) can serve as a cost effective method to treat high salinity wastewaters, especially if waste heat is utilized for its operation. The goal of this work is to study the feasibility of employing MD technology for the treatment of high salinity wastewaters which are generated as a result of natural gas production and active reservoir management for CO 2 sequestration. This study also aimed at quantifying the availability of waste heat which could be used as the primary source of thermal energy to drive the MD process. Bench scale studies were carried out with several commercially available membranes using both synthetic and actual high salinity wastewaters. The membranes tested with real wastewater samples exhibited excellent rejection of dissolved ions, including naturally occurring radioactive material (NORM). Long term bench scale experiments with real produced water from the Marcellus shale play revealed that iron oxide could precipitate on the feed side of direct contact MD (DCMD) module but had a negligible effect on the performance of the system. Based on the bench scale experiments, an ASPEN Plus simulation, which incorporated a mathematical model with fundamental heat and mass transfer equations, was developed and used to evaluate the process energy requirements. Despite low operating temperature and pressure for MD, it had a large thermal energy requirement for operation, which could make this technology expensive compared to reverse osmosis (RO) and forward osmosis (FO). However, it is important to note that RO and FO have limited applicability for high salinity shale gas wastewater. Moreover, MD could be integrated with renewable energy sources such as wind or solar energy or industrial waste heat sources to offset the thermal energy requirements and enhance the economics of wastewater treatment. Natural gas compressor stations (NG CS) have been proposed in this study as the source of waste heat based on the estimate of quantity and quality of available waste heat in the exhaust streams of gas turbine and internal combustion compressor engines. Using the actual installed capacity and location of compressor stations in the U.S., this analysis revealed that an average of 610 TJ/day of thermal energy is available at existing NG CS and that this source of waste heat is of high quality with temperatures above 645 K. A systems-level integration of MD with waste heat from NG CS revealed that approximately 56% of available waste heat at NG CS in Pennsylvania is sufficient to concentrate (from 10% to 30% salinity) all wastewater associated with shale gas extraction. Techno-economic assessment (TEA) accounting for capital as well as operating and maintenance costs with and without waste heat integration was conducted for a hypothetical 0.5 million gallons per day (MGD) DCMD plant using experimental and modeling results from this study. TEA revealed that the total cost of shale gas wastewater treatment using MD is $5.7/m 3 feed for the base case scenario in which the thermal energy requirements are met by external steam, however, the total cost can be reduced to $0.74/m 3 feed when integrated with free waste heat from NG CS. Sensitivity analysis revealed that thermal energy cost and feed TDS are the most important factors in total cost of high salinity wastewater treatment using DCMD.

03 NATURAL GAS↗

Arrhenius Analysis of the Degradation Modes in BackFLIP Study of Emerging Photovoltaic Backsheets: Preprint

With increasingly large-scale deployments of photovoltaic (PV) modules to meet global energy demands, interest in better establishing module lifespans is growing. We report on the performance of co-extruded polyolefin- (PO) based backsheets as environmentally friendly alternatives to fluoropolymer-reinforced polyethylene-terephthalate- (PET)-based backsheets using three hygrometric accelerated test conditions. After completing 4000 cumulative hours of aging, we analyzed data from electrical performance (I-V), surface roughness (gloss), and appearance (L, a*, b* color) characterizations are analyzed to quantify degradation rates, quantify the corresponding activation energy, and cross-correlate between the characteristics examined, thereby providing insights into the relationship between physical characteristics and operating performance.

BackFLIP↗

Construction, Test And Calibration of the GLAST Silicon Tracker

The Gamma-ray Large Area Space Telescope represents a great advance in space application of silicon detectors. With a surface of 80 m{sup 2} and about 1 M readout channels it is the largest silicon tracker ever built for a space experiment. GLAST is an astro-particle mission that will study the mostly unexplored, high energy (20 MeV-300 GeV) spectrum coming from active sources or diffused in the Universe. The detector integration and test phase is complete. The full instrument underwent environmental testing and the spacecraft integration phase has just started: the launch is foreseen in late 2007. In the meanwhile the spare modules are being used for instrument calibration and performance verification employing the CERN accelerator complex. A Calibration Unit has been exposed to photon, electron and hadron beams from a few GeV up to 300 GeV. We report on the status of the instrument and on the calibration campaign.

Instrumentation,OTHER↗

Apparatus for fixing latency

An apparatus for fixing computational latency within a deterministic region on a network comprises a network interface modem, a high priority module and at least one deterministic peripheral device. The network interface modem is in communication with the network. The high priority module is in communication with the network interface modem. The at least one deterministic peripheral device is connected to the high priority module. The high priority module comprises a packet assembler/disassembler, and hardware for performing at least one operation. Also disclosed is an apparatus for executing at least one instruction on a downhole device within a deterministic region, the apparatus comprising a control device, a downhole network, and a downhole device. The control device is near the surface of a downhole tool string. The downhole network is integrated into the tool string. The downhole device is in communication with the downhole network.

97 MATHEMATICS AND COMPUTING↗

TH-EF-BRB-10: Dosimetric Validation of a Trajectory Based Cranial SRS Treatment Technique On a Varian TrueBeam Linac

Purpose: This work investigates the dosimetric accuracy of a trajectory based delivery technique in which an optimized radiation beam is delivered along a Couch-Gantry trajectory that is formed by simultaneous rotation of the linac gantry and the treatment couch. Methods: Nine trajectory based cranial SRS treatment plans were created using in-house optimization software. The plans were calculated for delivery on the TrueBeam STx linac with 6MV photon beam. Dose optimization was performed along a user-defined trajectory using MLC modulation, dose rate modulation and jaw tracking. The pre-defined trajectory chosen for this study is formed by a couch rotation through its full range of 180 degrees while the gantry makes four partial arc sweeps which are 170 degrees each. For final dose calculation, the trajectory based plans were exported to the Varian Eclipse Treatment Planning System. The plans were calculated on a homogeneous cube phantom measuring 18.2×18.2×18.2 cm3 with the analytical anisotropic algorithm (AAA) using a 1mm3 calculation voxel. The plans were delivered on the TrueBeam linac via the developer’s mode. Point dose measurements were performed on 9 patients with the IBA CC01 mini-chamber with a sensitive volume of 0.01 cc. Gafchromic film measurements along the sagittal and coronal planes were performed on three of the 9 treatment plans. Point dose values were compared with ion chamber measurements. Gamma analysis comparing film measurement and AAA calculations was performed using FilmQA Pro. Results: The AAA calculations and measurements were in good agreement. The point dose difference between AAA and ion chamber measurements were within 2.2%. Gamma analysis test pass rates (2%, 2mm passing criteria) for the Gafchromic film measurements were >95%. Conclusion: We have successfully tested TrueBeam’s ability to deliver accurate trajectory based treatments involving simultaneous gantry and couch rotation with MLC and dose rate modulation along the trajectory.

60 APPLIED LIFE SCIENCES↗

Structured light approaches in laser-based plasma diagnostics

There is a growing demand for plasma diagnostics suitable for industrial plasma reactors employed in semiconductor nanofabrication, especially relevant to microelectronics and quantum information systems. Such reactors typically have limited optical access and pose considerable diagnostic challenges, including intense background emission, significant thermal loads, and contamination of optical viewports. In this study, we outline research into structured light techniques (laser beams with tailored spatial, temporal, or phase characteristics) that effectively overcome these issues using laser-induced fluorescence (LIF) as an example. The focus of presented diagnostics is on ion kinetics analysis within an industrial plasma source, although this approach is broadly applicable to other plasma systems and diagnostic contexts. We present a confocal LIF implementation using an axicon-generated Bessel annular beam, achieving spatial resolutions of approximately 5 mm at a focal distance of 300 mm, with potential improvements to about 1 mm. This approach matches conventional orthogonal LIF performance but requires only one optical port. Wavelength-modulation LIF employs nonlinear laser wavelength tuning to measure spectral line derivatives, suppressing background emission and enhancing details of spectral line shape. Additionally, we present new results on applying vortex beams (laser beams carrying orbital angular momentum, OAM) for LIF measurements in an industrial plasma device. These measurements enable simultaneous axial and tangential velocity determination using a single laser beam and have been tested with xenon ion transition. Initial quantification of results was performed. Together, these structured-light approaches provide robust, background-resilient, multi-dimensional diagnostics for complex plasma environments.

Romadanov, Ivan [Princeton Plasma Physics Laborato↗