Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Ion probe beam experiments and kinetic modeling in a dense plasma focus Z-pinch

The Z-pinch phase of a dense plasma focus (DPF) emits multiple-MeV ions in a ∼cm length. The mechanisms through which these physically simple devices generate such high energy beams in a relatively short distance are not fully understood. We are exploring the origins of these large gradients using measurements of an ion probe beam injected into a DPF during the pinch phase and the first kinetic simulations of a DPF Z-pinch. To probe the accelerating fields in our table top experiment, we inject a 4 MeV deuteron beam along the z-axis and then sample the beam energy distribution after it passes through the pinch region. Using this technique, we have directly measured for the first time the acceleration of an injected ion beam. Our particle-in-cell simulations have been benchmarked on both a kJ-scale DPF and a MJ-scale DPF. They have reproduced experimentally measured neutron yields as well as ion beams and EM oscillations which fluid simulations do not exhibit. Direct comparisons between the experiment and simulations enhance our understanding of these plasmas and provide predictive design capability for accelerator and neutron source applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal diffusion in Ni/Al multilayer

Two Ni/Al multilayers deposited by ion beam sputtering of nominal design [Ni(200A)/Al(100A)] Multiplication-Sign 5 and [Ni(50A)/Al(227A)] Multiplication-Sign 5 on Si substrates were annealed at 200 Degree-Sign C. As-deposited and annealed samples were characterized by x-ray diffraction (XRD) and x-ray reflectometry (XRR). The effort was to study the path of alloying in the above two multilayers of same elements but of opposite stoichiometric ratio. We find distinct differences in alloying of these samples.

36 MATERIALS SCIENCE↗

Optima HD Imax: Molecular Implant

Molecular implantation offers semiconductor device manufacturers multiple advantages over traditional high current ion implanters. The dose multiplication due to implanting more than one atom per molecule and the transport of beams at higher energies relative to the effective particle energies result in significant throughput enhancements without risk of energy contamination. The Optima HD Imax is introduced with molecular implant capability and the ability to reach up to 4.2 keV effective {sup 11}B from octadecaborane (B{sub 18}H{sub 22}). The ion source and beamline are optimized for molecular species ionization and transport. The beamline is coupled to the Optima HD mechanically scanned endstation. The use of spot beam technology with ionized molecules maximizes the throughput potential and produces uniform implants with fast setup time and with superior angle control. The implanter architecture is designed to run multiple molecular species; for example, in addition to B{sub 18}H{sub 22} the system is capable of implanting carbon molecules for strain engineering and shallow junction engineering. Source lifetime data and typical operating conditions are described both for high dose, memory applications such as dual poly gate as well as lower energy implants for source drain extension and contact implants. Throughputs have been achieved in excess of 50 wafers per hour at doses up to 1x10{sup 16} ions/cm{sup 2} and for energies as low as 1 keV.

36 MATERIALS SCIENCE↗

Measurement of fifth- and sixth-order fluctuations of (net-)proton number in Au + Au collisions from phase II of the beam energy scan program at RHIC

We report high-statistics measurements of fifth- and sixth-order factorial cumulants and cumulant ratios of (net-)proton multiplicity distributions in Au+Au collisions at $\sqrt{s_{NN}}$ = 7.7–27GeV, using data from the STAR experiment collected during the Beam Energy Scan Phase II at RHIC. Protons and antiprotons are identified at midrapidity (|𝑦| < 0.5) with transverse momentum 0.4 < 𝑝 𝑇 < 2.0GeV/𝑐. The proton factorial cumulants 𝜅 4 , 𝜅 5 , and 𝜅 6 increase with order but exhibit no sign alternation within current uncertainties, offering no evidence for a two-component structure in the proton multiplicity distribution, as might be expected near a first-order phase transition. The cumulant ratios 𝐶 5 /𝐶 1 and 𝐶 6 /𝐶 2 fluctuate around zero in collisions at 0–40% centrality. The results are consistent with both the negative predictions from lattice QCD and the positive trends obtained from the ultrarelativistic quantum molecular dynamics (UrQMD) model. At $\sqrt{s_{NN}}$ ≳ 27GeV, the 𝐶 4 /𝐶 2 and 𝐶 5 /𝐶 1 results are compatible with predictions from lattice QCD, functional renormalization group (FRG), and hadron resonance gas (HRG) models, while UrQMD describes the data better at lower energies. Here, these measurements place constraints on baryon number fluctuations and offer valuable insights into the QCD phase structure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-T-487: On-Site Beam Matching of An Elekta Infinity with Agility MLC with An Elekta Versa HD

Purpose: Historically, beam matching of similar Linear Accelerators has been accomplished by sending beam data to the manufacturer to match at their factory. The purpose of this work is to demonstrate that fine beam matching can be carried out on-site as part of the acceptance test, with similar or better results. Methods: Initial scans of a 10 × 10 Percent depth dose (PDD) and a 40 × 40 beam profile at the depth of Dmax, for 6MV and 10 MV were taken to compare with the standard beam data from the Versa. The energy was then adjusted and the beam steered to achieve agreement between the depth dose and the horns of the beam profile. This process was repeated until the best agreement between PDD and profiles was achieved. Upon completion, all other clinical data were measured to verify match. This included PDD, beam profiles, output factors and Wedge factors. For electron beams PDD’s were matched and the beam profiles verified for the final beam energy. Confirmatory PDD and beam profiles for clinical field sizes, as well as Output Factors were measured. Results: The average difference in PDD’s for 6MV and 10MV were within 0.4% for both wedged and open fields. Beam profile comparisons over the central 80% of the field, at multiple depths, show agreement of 0.8% or less for both wedged and open fields. Average output factor agreement over all field sizes was 0.4% for 6MV and 0.2 % for 10MV. Wedge factors agreement was less than 0.6% for both photon energies over all field sizes. Electron PDD agreed to 0.5mm. Cone ratios agreed to 1% or less. Conclusion: This work indicates that beam matching can be carried out on-site simply and quickly. The results of this beam matching can achieve similar or better results than factory matching.

43 PARTICLE ACCELERATORS↗

Resistive Wall Simulations with LAMDA

The prospect for a new downstream transport (DST) beam line for multipulse target testing (MPTL) has raised questions about the resistive-wall instability, which has been theoretically shown to couple between the multiple pulses in a pulse train. Recent upgrades to computer operating systems and the LAMDA beam dynamics code mandate that the code be revalidated before using to explore MPTL parameters. This note is a brief account of the revalidation of LAMDA for resistive wall problems.

43 PARTICLE ACCELERATORS↗

Strong room-temperature ferromagnetism of high-quality lightly Mn-doped ZnO grown by molecular beam epitaxy

Strong room-temperature ferromagnetism is demonstrated in single crystalline Mn-doped ZnO grown by molecular beam epitaxy. With a low Mn concentration of 2 Multiplication-Sign 10{sup 19} cm{sup -3}, Mn-doped ZnO films exhibited room-temperature ferromagnetism with a coercivity field larger than 200 Oe, a large saturation moment of 6 {mu}{sub B}/ion, and a large residue moment that is {approx}70% of the saturation magnetization. Isolated ions with long range carrier mediated spin-spin coupling may be responsible for the intrinsic ferromagnetism.

36 MATERIALS SCIENCE↗

Evaluation of hybrid depth scanning for carbon-ion radiotherapy

Purpose: In radiotherapy with a scanned carbon-ion beam, its Bragg peak is shifted along the depth direction either by inserting the range shifter plates or by changing the beam-extraction energy of a synchrotron. In the former technique (range shifter scanning: RS), the range shifter plates broaden the beam size and produce secondary fragments through nuclear reactions. In the latter technique (active-energy scanning: ES), it may take several seconds to change the beam energy depending on the synchrotron operation cycle, leading to a long treatment time. The authors propose a hybrid depth scan technique (hybrid scanning: HS), where several beam energies are used in conjunction with the range shifter plates for finer range shift. In this study, HS is evaluated from the viewpoints of dose distribution and treatment time. Methods: Assuming realistic accelerator and beam-delivery systems, the authors performed computer simulations using GEANT4 Monte Carlo code for beam modeling and a treatment planning system to evaluate HS. Three target volumes with the same dimensions of 60 x 60 x 60 mm{sup 3} were generated at depths of 45, 85, and 125 mm in water phantom, and uniform clinical dose was planned for these targets. The sizes of lateral dose falloff and the peak to plateau ratio defined as the ratio of the clinical dose averaged over the target to the clinical dose at the entrance as well as the treatment time were compared among the three depth scan techniques. Results: The sizes of lateral dose falloffs at the center of SOBP are 11.4, 8.5, and 5.9 mm for the three targets in RS, while they are 5.7, 4.8, and 4.6 mm in ES and 6.6, 5.7, and 5.0 mm in HS, respectively. The peak to plateau ratios are 1.39, 1.96, and 2.15 in RS, while they are 1.48, 2.04, and 2.19 in ES and 1.47, 2.03, and 2.18 in HS, respectively. The treatment times are 128.7, 128.6, and 128.6 s in ES, while they are 61.2, 54.6, and 47.8 s in RS and 43.2, 44.1, and 44.7 s in HS, respectively. The multiple scattering and the nuclear reaction by range shifter degraded the beam qualities such as lateral dose falloff and peak to plateau ratio, which was especially pronounced for the shallow target in RS. The depth scan timing was limited by accelerator cycle in ES. That increased the treatment time by a few times. Conclusions: This study revealed that HS can provide dose distributions with steeper lateral dose falloffs and higher peak to plateau ratio comparing to RS and comparable to ES. In addition, the treatment time can be considerably reduced in HS compared to ES.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Leakage and scatter radiation from a double scattering based proton beamline

Proton beams offer several advantages over conventional radiation techniques for treating cancer and other diseases. These advantages might be negated if the leakage and scatter radiation from the beamline and patient are too large. Although the leakage and scatter radiation for the double scattering proton beamlines at the Loma Linda University Proton Treatment Facility were measured during the acceptance testing that occurred in the early 1990s, recent discussions in the radiotherapy community have prompted a reinvestigation of this contribution to the dose equivalent a patient receives. The dose and dose equivalent delivered to a large phantom patient outside a primary proton field were determined using five methods: simulations using Monte Carlo calculations, measurements with silver halide film, measurements with ionization chambers, measurements with rem meters, and measurements with CR-39 plastic nuclear track detectors. The Monte Carlo dose distribution was calculated in a coronal plane through the simulated patient that coincided with the central axis of the beam. Measurements with the ionization chambers, rem meters, and plastic nuclear track detectors were made at multiple locations within the same coronal plane. Measurements with the film were done in a plane perpendicular to the central axis of the beam and coincident with the surface of the phantom patient. In general, agreement between the five methods was good, but there were some differences. Measurements and simulations also tended to be in agreement with the original acceptance testing measurements and results from similar facilities published in the literature. Simulations illustrated that most of the neutrons entering the patient are produced in the final patient-specific aperture and precollimator just upstream of the aperture, not in the scattering system. These new results confirm that the dose equivalents received by patients outside the primary proton field from primary particles that leak through the nozzle are below the accepted standards for x-ray and electron beams. The total dose equivalent outside of the field is similar to that received by patients undergoing treatments with intensity modulated x-ray therapy. At the center of a patient for a whole course of treatment, the dose equivalent is comparable to that delivered by a single whole-body XCT scan.

61 RADIATION PROTECTION AND DOSIMETRY↗

Search for an Excess of Electron Neutrino Interactions in MicroBooNE Using Multiple Final State Topologies (submitted to PRL)

We present a measurement of ν e interactions from the Fermilab Booster Neutrino Beam using the MicroBooNE liquid argon time projection chamber to address the nature of the excess of low energy interactions observed by the MiniBooNE collaboration. Three independent ν e searches are performed across multiple single electron final states, including an exclusive search for two-body scattering events with a single proton, a semi-inclusive search for pionless events, and a fully inclusive search for events containing all hadronic final states. With differing signal topologies, statistics, backgrounds, reconstruction algorithms, and analysis approaches, the results are found to be consistent with the nominal ν e rate expectations from the Booster Neutrino Beam and no excess of ν e events is observed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of chromatic-dispersion-induced chirp on the temporal coherence properties of individual beams from spontaneous four-wave mixing

Temporal coherence of individual signal or idler beam, determined by the spectral correlation property of photon pairs, is important for realizing quantum interference among independent sources. Based on spontaneous four-wave mixing in optical fibers, we study the effect of chirp on the temporal coherence property by introducing a different amount of chirp into either the pulsed pump or individual signal (idler) beam. The investigation shows that the pump chirp induces additional frequency correlation into photon pairs; the mutual spectral correlation of photon pairs and the coherence of individual beam can be characterized by measuring the intensity correlation function g{sup (2)} of the individual beam. To improve the coherence degree, the pump chirp should be minimized. Moreover, a Hong-Ou-Mandel-type two-photon interference experiment with the signal beams generated in two different fibers illustrates that the chirp of the individual signal (idler) beam does not change the temporal coherence degree, but affects the temporal mode matching. To achieve high visibility among multiple sources, apart from improving the coherence degree, mode matching should be optimized by managing the chirps of individual beams.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Relativistic beaming and the nuclei of double-lobed radio quasars

A complete sample of double-lobed 3CR quasars with minimal orientation bias is defined. Properties of these objects on the greater than kpc scale are consistent with the simple beaming model for their nuclei. VLBI maps of six nuclei reveal 'core-jet' structures. Both nuclei mapped at multiple epochs are modestly superluminal. The distribution of apparent velocities in this sample will provide a stringent test of beaming.

Hough, D. H.↗

Generation of quasi-monochromatic beams of accelerated electrons during interaction of weak-contrast intense femtosecond laser radiation with a metal-foil edge

The formation of monoenergetic beams of accelerated electrons by focusing femtosecond laser radiation with an intensity of 2 Multiplication-Sign 10{sup 17} W cm{sup -2} onto an edge of aluminium foil has been experimentally demonstrated. The electrons had energy distributions peaking in the range from 0.2 to 0.8 MeV and an energy spread less than 20 %. The acceleration mechanism related to the generation of a plasma wave as a result of self-modulation instability of the laser pulse in the subcritical plasma formed the prepulse of the laser system (arriving 10 ns before the main pulse) is considered. Onedimensional PIC simulation of the interaction between the laser radiation and plasma with a concentration of 5 Multiplication-Sign 10{sup 19} cm{sup -3} showed that effective excitation of a plasma wave, as well as the trapping and acceleration of the electron beam with an energy on the order of 1 MeV, may occur in the presence of inhomogeneities in the density at the plasma boundary and in the temporal shape of the beam. (extreme light fields and their applications)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation of quantum-electrodynamic cascades in oblique collisions of ultrarelativistic electrons with an intense laser field

Quantum-electrodynamic cascade generation is numerically simulated for the case of the oblique collision of a beam of ultrarelativistic electrons with the field of two counterpropagating, focused, circularly polarised laser pulses. It is shown that although the 'collapse and revival' effect is observed at any value of the collision angle, the multiplicity of the cascade essentially depends on this angle and is maximal in the configuration, when the electron beam hits the focus perpendicularly to the optical axis of the laser pulses. (extreme laser radiation: physics and fundamental applications)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In situ x-ray studies of growth of complex oxides on graphene by molecular beam epitaxy

Future technologies are likely to exploit flexible heterostructures exhibiting multifunctional properties constructed from multiple materials. One technique for the synthesis of such systems relies on remote epitaxy, a method employing graphene as a sacrificial layer between a crystalline substrate and an epitaxial film. The technique can be used to create single crystal heterostructures comprised of stacked epitaxial films, their properties optimized by minimizing incompatibilities between the different materials. Details regarding nucleation and growth via remote epitaxy remain unknown, however, due to the many difficulties in studying synthesis in the growth environment with atomic-scale resolution. Here, we describe an in situ synchrotron x-ray investigation of complex oxide thin film growth on graphene by molecular beam epitaxy. Phase retrieval methods were used to reconstruct the electron density profiles from x-ray crystal truncation rods measured under different growth conditions. Our in situ observations combined with post-growth spectroscopy provide a number of key insights regarding graphene in the synthesis environment and the resulting effects on the complex oxide/graphene heterostructure.

36 MATERIALS SCIENCE↗

Self-focusing of profiled ultrashort-wavelength laser beams in air

We report on the results of laboratory experiments of filamentation of sharply focused gigawatt femtosecond laser radiation passed through various aperture diaphragms in air. For the multiple filamentation regime, the dependences of the length and spatial structure of the filamentation region on the initial beam profile are established. It is found that light beam profiling by a diaphragm leads in some cases to a displacement of the filamentation region and to repeated self-focusing of radiation behind the linear focal waist. In the beam of the same power in the absence of a diaphragm and in the regime of the formation of a single filament, this effect terminates in front of the geometrical focus. The experimental results are illustrated by numerical simulation data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-beam laser altimeter

Laser altimetry provides a high-resolution, high-accuracy method for measurement of the elevation and horizontal variability of Earth-surface topography. The basis of the measurement is the timing of the round-trip propagation of short-duration pulses of laser radiation between a spacecraft and the Earth's surface. Vertical resolution of the altimetry measurement is determined primarily by laser pulsewidth, surface-induced spreading in time of the reflected pulse, and the timing precision of the altimeter electronics. With conventional gain-switched pulses from solid-state lasers and sub-nsec resolution electronics, sub-meter vertical range resolution is possible from orbital attitudes of several hundred kilometers. Horizontal resolution is a function of laser beam footprint size at the surface and the spacing between successive laser pulses. Laser divergence angle and altimeter platform height above the surface determine the laser footprint size at the surface, while laser pulse repetition-rate, laser transmitter beam configuration, and altimeter platform velocity determine the space between successive laser pulses. Multiple laser transitters in a singlaltimeter instrument provide across-track and along-track coverage that can be used to construct a range image of the Earth's surface. Other aspects of the multi-beam laser altimeter are discussed.

Bufton, Jack L.↗

Simulations Supporting the Development of Northstar's Indirect Beam Parameters Monitoring System

NorthStar Medical Radioisotopes, LLC is planning to produce the important medical radioisotope molybdenum-99 (Mo-99), the parent of technetium-99m (Tc-99m), through photonuclear reactions in molybdenum-100 (Mo-100). In this approach, a target comprising multiple thin disks of enriched molybdenum metal is bombarded with a 40-MeV electron beam. Electrons impinged on the molybdenum target produce bremsstrahlung X-rays that cause the nuclear reaction. Because enriched Mo-100 is expensive, there is a desire to utilize as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (and heat deposition in the target), which creates challenging requirements for the cooling of the target. The critical part of the target is the target window. It separates the high-pressure helium cooled target from the vacuum beamline and the subject of structural and thermal stress. The temperature of the target window is proportional to the energy density deposited by the beam, so it is critical to maintain the desired beam profile on the target window. The feasibility of indirectly monitoring the maximum energy density of the beam on the beam window through beam losses at the main collimator (Collimator) before the production target was verified. A model of the NorthStar beam transport line was constructed for this purpose using MAD-X and Tao/Bmad codes. Beam optics were computed for the standard operational scenario, followed by an investigation involving approximately 400 cases with parameter variations in the last tuning quadrupoles. This was done to assess the correlation between losses in the collimator and the peak energy density on the target. We developed a model to explore the potential application of Optical transition radiation (OTR) for controlling beam parameters in the NorthStar beam delivery system. This model was based on a generic formula derived from the fundamental solution of the inhomogeneous wave equation of the vector potential, and allowed us to consider various surfaces, even those with irregular or random features, using numerical integration. We applied the model to OTR generated by relativistic electrons impacting an Inconel® 718 beam window. We examined cases with different levels of the window’s surface roughness, ranging from 0.5 to 3.0 microns of root square mean (RMS) deviation. The results of the OTR simulations provided distributions of OTR photons that can be used to study the limitations of optical systems for controlling beam parameters.

43 PARTICLE ACCELERATORS↗