Search NASA⌕ Search

SEARCH · Search NASA

Results for “plane of array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Singular value decomposition with systolic arrays

Systolic arrays for determining the singular value decomposition of a mxn, m n, matrix A of bandwidth w are presented. After A has been reduced to bidiagonal form B by means of Givens plane rotations, the singular values of B are computed by the Golub-Reinsch iteration. The products of plane rotations form the matrices of left and right singular vectors. Assuming each processor can compute or supply a plane rotation, O(wn) processors accomplish the reduction to bidiagonal form in O(np) steps, where p is the number of superdiagonals. A constant number of processors then determines each singular value in about 6n steps. The singular vectors are computed by rerouting the rotations through the arrays used for the reduction to bidiagonal form, or else along the way by employing another rectangular array of O(wm) processors.

Ipsen, I. C. F.↗

The X-ray Integral Field Unit (X-IFU) for Athena

Athena is designed to implement the Hot and Energetic Universe science theme selected by the European Space Agency for the second large mission of its Cosmic Vision program. The Athena science payload consists of a large aperture high angular resolution X-ray optics (2 m2 at 1 keV) and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager. The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), oering 2.5 eV spectral resolution, with approximately 5" pixels, over a field of view of 5' in diameter. In this paper, we present the X-IFU detector and readout electronics principles, some elements of the current design for the focal plane assembly and the cooling chain. We describe the current performance estimates, in terms of spectral resolution, effective area, particle background rejection and count rate capability. Finally, we emphasize on the technology developments necessary to meet the demanding requirements of the X-IFU, both for the sensor, readout electronics and cooling chain.

X-ray↗

Roughness of Ti Substrates for Control of the Preferred Orientation of TiO 2 Nanotube Arrays as a New Orientation Factor

We report the surface roughness of a Ti substrate as a critical factor for controlling the degree of the preferred orientation of anatase TiO2 nanotube arrays (NTAs) which are synthesized by anodization and a subsequent annealing process. The degree of the preferred orientation to the (004) plane of the anatase crystal structure has a strong dependency on the root-mean-square roughness (Sq) of the initial Ti substrate when the roughness-controlled substrates are anodized in an ethylene glycol-based electrolyte containing ~2 wt % of water. Highly preferred oriented NTAs were obtained from low-Sq (<10 nm) substrates, which were accompanied by uniform pore distribution and low concentration of hydroxyl ions in as-anodized amorphous NTAs. The mechanism of the preferred oriented crystallization of nanometer-scaled tube walls is explained considering the microscopic geometrical uniformity of the oxide barrier and nanopores at the early stage of anodization, which affected the local electric field and thus the insertion of the hydroxyl group into the amorphous TiO2 tube walls.

14 SOLAR ENERGY↗

SU-C-209-07: Phantoms for Digital Breast Tomosynthesis Imaging System Evaluation

Purpose: Digital Breast Tomosynthesis (DBT) is gaining importance in breast imaging. There is a need for phantoms that can be used for image evaluation and comparison. Existing commercially available phantoms for DBT are expensive and may lack clinically relevant test objects. The purpose of this study is to develop phantoms for DBT evaluation. Methods Four phantoms have been designed and constructed to assess the image quality (IQ) of two DBT systems. The first contains a spiral of 0.3 mm SiC beads in gelatin to measure the tomographic slice thickness profile and uniformity of coverage in a series of tomographic planes. The second contains simulated tumors inclined with respect to the phantom base to assess tomographic image quality. The third has a tilted array of discs with varying contrast and diameter. This phantom was imaged alone and in a stack of TE slabs giving 2 to 10 cm thickness. The fourth has a dual wedge of glandular and adipose simulating materials. One wedge contains discs with varying diameter and thickness; the other supports a mass with six simulated spicules of varying size and a cluster of simulated calcifications. The simulated glandular tissue material varies between 35 and 100% of the total thickness (5.5 cm). Results: All phantoms were scanned successfully. The best IQ comparison was achieved with the dual wedge phantom as demonstrated by the spiculated mass and calcifications. Images were evaluated by two radiologists and one physicist. The projection images and corresponding set of tomographic planes were comparable and the synthesized projection images were inferior to the projection images for both systems. Conclusion: Four phantoms were designed, constructed and imaged on two DBT systems. They successfully demonstrated performance differences between two systems, and between true and synthesized projection images. Future work will incorporate these designs into a single phantom.

60 APPLIED LIFE SCIENCES↗

Non-linear phenomena in films of solar arrays

The paper assesses nonlinear effects in films which are associated with the instability of their shape as a result of contractions during longitudinal and transverse in-plane oscillations. The following problems are solved analytically: transverse in-plane oscillations, longitudinal oscillations in films of rotating solar sail, transverse in-plane oscillations in films of a rotating solar sail, and effect of damping in films of a rotating solar sail. The reason for damping lies in the loss of kinetic energy during absorption of the film particles by root wrinkles without reflection (absolutely inelastic shock).

Zak, M.↗

Integrating indium antimonide linear arrays at 65K and below

A schematic is presented of a simplified electronic architecture of experimental 128 element infrared imager. Tables are given of sample diode responsivity, 512 element focal plane performance summary, and 128 element FPA mechanical and electrical characteristics. Typical 43 x 43 micron detector IV characteristics at 84 K are given, along with typical 43 x 43 micron Indium Antimonide CV characteristic at 83 K.

Bailey, Gary C.↗

The 12x32 Pop-Up Bolometer Array for the SHARC II Camera

SHARC II is a 350 micron facility camera for the Caltech Submillimeter Observatory (CSO) expected to come on-line in 2002. The key component of SHARC II is a 12x32 array of doped silicon 'pop-up' bolometers developed at NASA/Goddard and delivered to Caltech in March 2002. Each pixel is 1 mm x 1 mm, coated with a 400 Omega/square bismuth film, and located lambda/4 above a reflective backshort to maximize radiation absorption. The pixels cover the focal plane with greater than 95% filling factor. Each doped thermistor occupies nearly the full area of the pixel to minimize 1/f noise. We report some results from the first cold measurements of this array. The bolometers were located inside a dark cover, and 4x32 pixels were read simultaneously. In the best 25% of winter nights on Mauna Kea, SHARC II is expected to have an NEFD at 350 microns of 1 Jy s(sup 1/2) or better.

Dowell, C. Darren↗

Directivity of planar array feeds for satellite reflector applications

Array-fed reflector antennas are used extensively in today's contour and multiple beam satellite antennas. To determine the directivity of these antennas theoretically, the total radiated power of the array feed must be accurately computed. In this paper, a closed-form expression for the radiated power is obtained for arrays with the well-known (cos theta q-type element patterns. The formulation is general, and takes into account polarization, nonsymmetric E- and H-plane element patterns, nonuniform element spacings and arbitrary complex excitation coefficients. Selective numerical data are presented to demonstrate the usefulness of this result. Comparisons are made with the available results obtained using direct numerical integration techniques, and with other available data based on less general formulations. Excellent agreement is observed for all cases. In particular, data are presented on the directivity of seven-element cluster feeds used in multiple beam designs, and an array feed for producing a contour beam covering the United States Eastern Time Zone (ETZ).

Rahmat-Samii, Y.↗

Microshutter Arrays for the NGST NIRSpec

We are developing a programmable multiobject field selector for the NGST NIRSpec. This device is a microshutter array, a close-packed 2000 x 2000 array of 100 micrometer x 100 micrometer shutters fabricated with Micro-ElectroMechanical Systems (MEMS) technologies. The shutters are opened using a magnet scanned over the array. The shutters are held open by electrostatic potentials on adjacent vertical electrodes. Modeling of the magnetic actuation of the microshutters allowed optimization of the magnetic field configuration, the distance between magnet and shutters, and the force and torque produced by the magnet. The results of laboratory tests are consistent with our modeling. We have demonstrated actuation, latching and addressing. We are able to rotate shutters out of the plane up to 90 degree and more, to latch them electrostatically to the walls and release them selectively. During the last six month all critical elements of the array have been demonstrated. Fabrication processes were developed to deposit vertical electrodes on support grid side walls and insulated light-shields that block the gaps between shutters and the support grid. Physical optics analysis was performed to assess the expected optical performance of the microshutters. A preliminary Fourier optics analysis on the microshutter array performance has been carried out. More detailed analysis of wave propagation through 3D structures is a next step. An optical test station for verifying optical parameters of the shutter array at room temperature has been developed. It allows to measure parameters, such as transmission, scattering, contrast ratio, and diffraction of the array structure. Initial data have been acquired and are being analyzed and compared to theoretical predictions.

Moseley, Harvey↗

Step Free Surface Heteroepitaxy of 3C-SiC Layers on Patterned 4H/6H-SiC Mesas and Cantilevers

Most SiC devices are implemented in homoepitaxial films grown on 4H/6H-SiC wafers with surfaces 3 degrees to 8 degrees off-axis from the (0001) basal plane. This approach has not prevented many substrate crystal defects from propagating into SiC epilayers, and does not permit the realization of SiC heteropolytype devices. This presentation describes recent advances in SiC epitaxial growth that begun to overcome the above shortcomings for arrays of mesas patterned into on-axis 4H/6H-SiC wafers. First, we demonstrated that atomic-scale surface steps can be completely eliminated from 4H/6H-SiC mesas via on-axis homoepitaxial step-flow growth, forming (0001) basal plane surfaces (up to 0.4 mm x 0.4 mm) for larger than previously thought possible. Step-free surface areas were then extended by growth fo thin lateral cantilevers from the mesa tops. These lateral cantilevers enabled substrate defects to be reduced and relocated in homoepitaxial films in a manner not possible with off-axis SiC growth. Finally, growth of vastly improved 3C-SiC heterofilms was achieved on 4H/6H-SiC mesas using the recently develop step-free surface heteroepitaxy process. These epitaxial growth developments should enable improved homojunction and heterojunction silicon carbide prototype devices.

Neudeck, Philip G.↗

Programmable Multiresolution CMOS Active Pixel Sensor

CMOS active pixel sensors (APS) allow the flexibility of placing signal processing circuitry on the imaging focal plane. The multiresolution CMOS APS can perform block averaging on-chip to eliminate the off-chip software intensive image processing. This 128 x 128 APS array can be read out at any user-defined resolution by configuring a set of digital shift registers. The resolution frame rate is 30 Hz with higher rates for all other image resolutions.

APS↗

The Synthesis, Structures, and Chemical Properties of Macrocyclic Ligands Covalently Bonded into Layered Arrays

In this part of the proposal we have concentrated on the surface functionalization of α-zirconium phosphate of composition Zr(O3POH)2•H2O. It is a layered compound that can be prepared as particles as small as 30 nm to single crystals in the range of cm. This compound is an ion exchanger with a capacity of 6.64 meq per gram. It finds use as a catalyst, proton conductor, sensors, biosensors, in kidney dialysis and drug delivery. By functionalizing the surface additional uses are contemplated as will be described. The layers consist of the metal, with 4+ charge, that is positioned slightly above and below the mean layer plane and bridged by three of the four phosphate oxygens. The remaining POH groups point into the interlayer space creating double rows of POH groups but single arrays on the surface layers. The surface groups are reactive and we were able to bond silanes, isocyanates, epoxides, acrylates ` and phosphates to the surface POH groups. The layers are easily exfoliated or filled with ions by ion exchange or molecules by intercalation reactions. Highlights of our work include, in addition to direct functionalization of the surfaces, replacement of the protons on the surface with ions of different charge. This allows us to bond phosphates, biophosphates, phosphonic acids and alcohols to the surface. By variation of the ion charge of the ions that replace the surface protons, different surface structures are obtained. We have already shown that polymer fillers, catalysts and Janus particles may be prepared. The combination of surface functionalization with the ability to insert molecules and ions between the layers allow for a rich development of numerous useful other applications as well as nano-surface chemistry.

36 MATERIALS SCIENCE↗

BATATA: a buried muon hodoscope

Muon hodoscopes have several applications, ranging from astrophysics to fundamental particle physics. In this work, we present a detector dedicated to the study, at ground level, of the main signals of cosmic-ray induced showers above 6 PeV. The whole detector is composed by a set of three parallel dual-layer scintillator planes buried at fix depths ranging from 120 g/cm{sup 2} to 600 g/cm{sup 2} and by a triangular array of water cerenkov detectors located nearby on ground.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron field parameter measurements on the JET tokamak by means of super-heated fluid detectors

The neutron field parameters (fluence and energy distribution) at a specific location outside the JET Torus Hall have been measured by means of super-heated fluid detectors (or 'bubble detectors') in combination with an independent, time-of-flight, technique. The bubble detector assemblies were placed at the end of a vertical line of sight at about 16 m from the tokamak mid plane. Spatial distributions of the neutron fluence along the radial and toroidal directions have been obtained using two-dimensional arrays of bubble detectors. Using a set of three bubble detector spectrometers the neutron energy distribution was determined over a broad energy range, from about 10 keV to above 10 MeV, with an energy resolution of about 30% at 2.5 MeV. The very broad energy response allowed for the identification of energy features far from the main fusion component (around 2.45 MeV for deuterium discharges).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Snapshot 3D tracking of insulin granules in live cells

Rapid and accurate volumetric imaging remains a challenge, yet has the potential to enhance understanding of cell function. We developed and used a multifocal microscope (MFM) for 3D snapshot imaging to allow 3D tracking of insulin granules labeled with mCherry in MIN6 cells. MFM employs a special diffractive optical element (DOE) to simultaneously image multiple focal planes. This simultaneous acquisition of information deteunines the 3D location of single objects at a speed only limited by the array detector's frame rate. We validated the accuracy of MFM imaging/tracking with fluorescence beads; the 3D positions and trajectories of single fluorescence beads can be detelinined accurately over a wide range of spatial and temporal scales. The 3D positions and trajectories of single insulin granules in a 3.2um deep volume were deteunined with imaging processing that combines 3D decovolution, shift correction, and finally tracking using the Imaris software package. We find that the motion of the granules is super diffusive, but less so in 3D than 2D for cells grown on coverslip surfaces, suggesting an anisotropy in the cytoskeleton (e.g. microtubules and action).

3D tracking↗

New dominance characteristics for the multivariable Nyquist array method

Three new dominance characteristics are introduced to the multivariable Nyquist array methods. The first characteristic utilizes a conformal mapping procedure to establish a new set of bands in the 'image' plane to assist in feedback gain selection and stability assessment. The second characteristic uses the 'image' band concept to provide a theoretical foundation for finite frequency dominance considerations, thus removing the restrictive requirement of dominance for all s on the Nyquist D contour. The third characteristic provides for the sharing of system dominance among the feedback control loops. The dominance sharing concept may be used to establish dominance and/or to improve the dominance condition in prespecified feedback loops.

Leininger, G. G.↗

Solar power satellite offshore rectenna study

Offshore rectennas are feasible and cost competitive with land rectennas but the type of rectenna suitable for offshore use is quite different from that specified in the present reference system. A nonground plane design minimizes the weight and greatly reduces the number of costly support towers. This perferred design is an antenna array consisting of individually encapsulated dipoles with reflectors or tagis supported on feed wires. Such a 5 GW rectenna could be built at a 50 m water depth site to withstand hurricane, winter storm, and icing conditions for a one time cost of $5.7 billion. Subsequent units would be about 1.3 less expensive. More benign and more shallow water sites would result in substantially lower costs. The major advantage of an offshore rectenna is the removal of microwave radiation from populated areas.

Source record↗

A system definition study for the Advanced Meteorological Temperature Sounder (AMTS)

The functional requirements of Exhibit A (11) were used as the baseline for the conceptual design of a fixed grating out of plane multidetector spectrometer for the Space Shuttle application. Because the grating instrument would be large and the 28 element detector array would be difficult to cool radiatively from a free flying spacecraft and because increasing the spectral resolution of the grating instrument would be difficult in an instrument of reasonable size, a parallel study of a Nichelson interferometer spectrometer was undertaken. This type of instrument offers compact size, fewer detectors to cool, and the possibility of increased spectral resolution. The design and performance parameters of both the grating and interferometer approaches are described. The tradeoffs involved in comparing the two systems for sounding applications are discussed.

Source record↗