Search NASA⌕ Search

SEARCH · Search NASA

Results for “randomized response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

WE-D-207-00: CT Lung Cancer Screening and the Medical Physicist: Moving Forward

In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancer Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in implementing Lung Cancer Screening protocols for CT, including utilizing resources such as the AAPM Protocols and the ACR Designated Lung Screening Center program. UCLA Department of Radiology has an Institutional research agreement with Siemens Healthcare; Dr. McNitt-Gray has been a recipient of Research Support from Siemens Healthcare in the past. Dr. Aberle has been a Member of Advisory Boards for the LUNGevity Foundation (2011-present) and Siemens Medical Solutions. (2013)

60 APPLIED LIFE SCIENCES↗

WE-D-207-01: Background and Clinical Implementation of a Screening Program

In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancer Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in implementing Lung Cancer Screening protocols for CT, including utilizing resources such as the AAPM Protocols and the ACR Designated Lung Screening Center program. UCLA Department of Radiology has an Institutional research agreement with Siemens Healthcare; Dr. McNitt-Gray has been a recipient of Research Support from Siemens Healthcare in the past. Dr. Aberle has been a Member of Advisory Boards for the LUNGevity Foundation (2011-present) and Siemens Medical Solutions. (2013)

60 APPLIED LIFE SCIENCES↗

WE-D-207-02: Capturing Data Elements and the Role of Imaging Informatics

In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancer Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in implementing Lung Cancer Screening protocols for CT, including utilizing resources such as the AAPM Protocols and the ACR Designated Lung Screening Center program. UCLA Department of Radiology has an Institutional research agreement with Siemens Healthcare; Dr. McNitt-Gray has been a recipient of Research Support from Siemens Healthcare in the past. Dr. Aberle has been a Member of Advisory Boards for the LUNGevity Foundation (2011-present) and Siemens Medical Solutions. (2013)

60 APPLIED LIFE SCIENCES↗

WE-D-207-03: CT Protocols for Screening and the ACR Designated Lung Screening Program

In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancer Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in implementing Lung Cancer Screening protocols for CT, including utilizing resources such as the AAPM Protocols and the ACR Designated Lung Screening Center program. UCLA Department of Radiology has an Institutional research agreement with Siemens Healthcare; Dr. McNitt-Gray has been a recipient of Research Support from Siemens Healthcare in the past. Dr. Aberle has been a Member of Advisory Boards for the LUNGevity Foundation (2011-present) and Siemens Medical Solutions. (2013)

60 APPLIED LIFE SCIENCES↗

High throughput single cell multiomics platform [Abstract]

In this collaborative project, PNNL and Scienion will co-develop an integrated microfluidic technology to co-measure the transcriptome and proteome in single cells. The technology will enable us to efficiently separate proteins from mRNA transcripts between two microchips, barcode the molecules, and measure them separately with next-generation sequencing and mass spectrometry, respectively. Multicellular organisms contain diverse cell types and tremendous cell-to-cell heterogeneity that dictates a multitude of biological functions in both physiological and pathological environments. Even in the case of microbes, these genetically identical organisms can randomly differentiate into many subpopulations that assume different roles for the survival of the community. Bulk-scale measurements are insufficient to resolve such complexities. The development and applications of high throughput single-cell omics technologies have transformed our understanding of cellular heterogeneities and their differential responses to internal signaling events or external stimulations. Despite these advances, most current single-cell omic technologies provide information on only one type of biomolecule. Perse, such measurements provide incomplete information because the cell phenotype is determined by multiple layers of biomolecules and the interplay between genome, epigenome, transcriptome, and proteome. For example, mRNA abundance in one cell can not be precisely referred to the corresponding DNA and protein in other cells because of the potential subtle difference in genotype (e.g., somatic mutation or copy number variation) or phenotype (external microenvironment and cell-cell interactions). As such, parallel measurement of multiple biomolecules in the same single cells can offer unique advantages compared with measuring them separately in different single cells. Scienion is a world-leading biotech company focusing on precision liquid handling and its application in single-cell whole-genome sequencing and RNA sequencing. PNNL is the leading institution in ultrasensitive mass spectrometry, microfluidics, and untargeted single-cell proteomics (scProteomics). This collaboration will facilitate a unique fusion between scTranscriptomics capability at Scienion and scProteomics capabilities at PNNL to, for the first time, perform both untargeted transcriptomics and proteomics from the same single cells.

59 BASIC BIOLOGICAL SCIENCES↗

HARMONIC SPACE ANALYSIS OF PULSAR TIMING ARRAY REDSHIFT MAPS

In this paper, we propose a new framework for treating the angular information in the pulsar timing array (PTA) response to a gravitational wave (GW) background based on standard cosmic microwave background techniques. We calculate the angular power spectrum of the all-sky gravitational redshift pattern induced at the Earth for both a single bright source of gravitational radiation and a statistically isotropic, unpolarized Gaussian random GW background. The angular power spectrum is the harmonic transform of the Hellings and Downs curve. We use the power spectrum to examine the expected variance in the Hellings and Downs curve in both cases. Finally, we discuss the extent to which PTAs are sensitive to the angular power spectrum and find that the power spectrum sensitivity is dominated by the quadrupole anisotropy of the gravitational redshift map.

79 ASTRONOMY AND ASTROPHYSICS↗

Test program to develop vibroacoustics test criteria for the Galileo bus

In order to define random vibration test requirements for Galileo bus-mounted hardware, an extensive vibroacoustics test program was conducted on hardware available from the previous Voyager spacecraft development program. The Galileo test program consisted of acoustic tests on three configurations of the Voyager Dynamic Test Model bus and shaker random vibration tests on two flight-like bus equipment bay assemblies and one dummy equipment bay assembly. The primary goal of the acoustic tests was to define vibration levels at locations on the bus structure representative of inputs to bus equipment bay assemblies and to obtain response data on bus bay subassemblies for correlation with the vibration tests response data. The primary purpose of the vibration tests was to determine if the vibration tests excited subassembly responses at least as severely as the bus acoustic tests.

Kern, D. L.↗

Probabilistic Structural Analysis Methods (PSAM) for Select Space Propulsion System Components

Probabilistic Structural Analysis Methods (PSAM) are described for the probabilistic structural analysis of engine components for current and future space propulsion systems. Components for these systems are subjected to stochastic thermomechanical launch loads. Uncertainties or randomness also occurs in material properties, structural geometry, and boundary conditions. Material property stochasticity, such as in modulus of elasticity or yield strength, exists in every structure and is a consequence of variations in material composition and manufacturing processes. Procedures are outlined for computing the probabilistic structural response or reliability of the structural components. The response variables include static or dynamic deflections, strains, and stresses at one or several locations, natural frequencies, fatigue or creep life, etc. Sample cases illustrates how the PSAM methods and codes simulate input uncertainties and compute probabilistic response or reliability using a finite element model with probabilistic methods.

Source record↗

Self-consistent calculation of nuclear photoabsorption cross sections: Finite amplitude method with Skyrme functionals in the three-dimensional real space

The finite amplitude method (FAM), which we have recently proposed [T. Nakatsukasa, T. Inakura, and K. Yabana, Phys. Rev. C 76, 024318 (2007)], significantly simplifies the fully self-consistent calculation of the random-phase approximation (RPA). This article presents a computational scheme of FAM suitable for systematic investigation and shows its performance for realistic Skyrme energy functionals. We adopt the mixed representation in which the forward and backward RPA amplitudes are represented by index of hole orbitals and of the spatial grid points for the three-dimensional real space. We solve a linear algebraic problem with a sparse non-Hermitian matrix, using an iterative method. We show results of the dipole response for selected spherical and deformed nuclei. The calculated peak energies of the giant dipole resonance well agree with experiments for heavy nuclei. However, they are systematically underestimated for light nuclei. We also discuss the width of the giant dipole resonance in the fully self-consistent RPA calculation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Flood Detection with Synthetic Aperture Radar: A Case Study of Houston, Texas Following Hurricane Harvey (2017) using C- and X-Band Observations

Hurricane Harvey produced record-breaking rainfall of up to 60 inches resulting in extensive flooding in Houston, Texas, in late August and early September of 2017. The slow forward motion of the storm following landfall left much of the area unobservable to optical remote sensing instruments for several days due to cloud cover. The active nature of Synthetic Aperture Radar (SAR) instruments allows for observations through clouds, which can supplement efforts to estimate hurricane-induced flood impacts. A growing fleet of SAR constellations has helped lower the latency of imagery following a hurricane, allowing for more timely detections of flooding to help support emergency response efforts. In this study, we leverage publicly available C-band SAR observations from the European Space Agency’s Sentinel-1B (S1B) satellite, collected on 30 August, and X-band SAR imagery collected on 1 September by the Airbus TanDEM-X (TDX) satellite made available through the NASA Commercial Smallsat Data Acquisition (CSDA) program. For each dataset, one co-polarized, StripMap, Radiometric Terrain Corrected (RTC) image was used to create a binary water/no water classification map by referencing permanent water in the Cropland Data Layer (CDL) dataset to determine thresholds. A validation dataset of randomly distributed “ground truth” points was generated using optical imagery from PlanetScope on 31 August, where the domain had relatively little cloud cover. We found that the S1B- and TDX-derived open water maps achieved overall accuracies of 94.17% and 91.57%, respectively. The variation in performance is attributed to both the penetrative abilities of C- and X-band SAR wavelengths in vegetated areas and the increased spatial resolution of the commercial SAR (~3 m) over Sentinel-1 (30 m). While publicly available Sentinel-1 observations are commonly relied upon in response and recovery efforts, these results suggest that including commercial X-band SAR imagery could be beneficial by providing both increased spatial resolution and more frequent revisits when deriving post-event flood mapping products.

Alexander M Melancon↗

Improving convergence of the Matrix Power Control Algorithm for random vibration testing

Herein, this paper describes modifications to the Matrix Power Control Algorithm (MPCA) to improve convergence for Random Vibration Control (RVC) testing. In particular, this paper presents Multiple-Input Multiple-Output (MIMO) implementations of MPCA in simulation and experiment. An Euler–Bernoulli beam model was simulated with applied base excitations and the Box Assembly with Removable Component (BARC) was used in experiment to validate results. The Bayesian optimization package Dragonfly was used to optimize control parameters. Additionally, a moving-average was employed and optimized to improve the measured response feedback for MPCA, reduce the number of averages needed to be taken between control updates, and further improve convergence. The key results of this paper show that the performance of MPCA can be improved by tuning the control parameters and by applying an optimized moving-average. Furthermore, it is demonstrated that convergence can be achieved within 12 drive-frames, which greatly enhances vibration control capability.

42 ENGINEERING↗

Combustion characteristics of fuel droplets with addition of nano and micron-sized aluminum particles

The burning characteristics of fuel droplets containing nano and micron-sized aluminum particles were investigated. Particle size, surfactant concentration, and the type of base fluid were varied. In general, nanosuspensions can last much longer than micron suspensions, and ethanol-based fuels were found to achieve much better suspension than n-decane-based fuels. Five distinctive stages (preheating and ignition, classical combustion, microexplosion, surfactant flame, and aluminum droplet flame) were identified for an n-decane/nano-Al droplet, while only the first three stages occurred for an n-decane/micron-Al droplet. For the same solid loading rate and surfactant concentration, the disruption and microexplosion behavior of the micron suspension occurred later with much stronger intensity. The intense droplet fragmentation was accompanied by shell rupture, which caused a massive explosion of particles, and most of them were burned during this event. On the contrary, for the nanosuspension, combustion of the large agglomerate at the later stage requires a longer time and is less complete because of formation of an oxide shell on the surface. This difference is mainly due to the different structure and characteristics of particle agglomerates formed during the early stage, which is a spherical, porous, and more-uniformly distributed aggregate for the nanosuspension, but it is a densely packed and impermeable shell for the micron suspension. A theoretical analysis was then conducted to understand the effect of particle size on particle collision mechanism and aggregation rate. The results show that for nanosuspensions, particle collision and aggregation are dominated by the random Brownian motion. For micron suspensions, however, they are dominated by fluid motion such as droplet surface regression, droplet expansion resulting from bubble formation, and internal circulation. And the Brownian motion is the least important. This theoretical analysis explains the different characteristics of the particle agglomerates, which are responsible for the different microexplosion behaviors that were observed in the experiments. (author)

33 ADVANCED PROPULSION SYSTEMS↗

Clinical Utility of Epstein-Barr Virus DNA Testing in the Treatment of Nasopharyngeal Carcinoma Patients

Epstein-Barr virus (EBV) DNA analysis has been shown to be useful for early detection, prognostication, and monitoring of treatment response of nasopharyngeal carcinoma (NPC), and the recent literature provides growing evidence of the clinical utility of EBV DNA testing, particularly to inform treatment decisions for NPC patients. Despite the fact that NPC is a rare disease, the NRG Oncology cooperative group has successfully activated a phase 2/3 randomized clinical trial for NPC with international partners and in that process has discovered that the development of a harmonized EBV DNA test is absolutely critical for integration into clinical trials and for future deployment in clinical and central laboratories. In November 2015, the National Cancer Institute (NCI) convened a workshop of international experts in the treatment of NPC and EBV testing to provide a forum for discussing the state of EBV DNA testing and its clinical utility, and to stimulate consideration of future studies and clinical practice guidelines for EBV DNA. This review provides a summary of that discussion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ge auto-doping and out-diffusion in InGaP grown on Ge substrate and their effects on the ordering of InGaP

We report on the Ge auto-doping and out-diffusion in InGaP epilayer with Cu-Pt ordering grown on 4-in. Ge substrate. Ge profiles determined from secondary ion mass spectrometry indicate that the Ge out-diffusion depth is within 100 nm. However, the edge of the wafer suffers from stronger Ge gas-phase auto-doping than the center, leading to ordering deterioration in the InGaP epilayer. In the edge, we observed a residual Cu-Pt ordering layer left beneath the surface, suggesting that the ordering deterioration takes place after the deposition rather than during the deposition and In/Ga inter-diffusion enhanced by Ge vapor-phase auto-doping is responsible for the deterioration. We thus propose a di-vacancy diffusion model, in which the amphoteric Ge increases the di-vacancy density, resulting in a Ge density dependent diffusion. In the model, the In/Ga inter-diffusion and Ge out-diffusion are realized by the random hopping of In/Ga host atoms and Ge atoms to di-vacancies, respectively. Simulation based on this model well fits the Ge out-diffusion profiles, suggesting its validity. By comparing the Ge diffusion coefficient obtained from the fitting and the characteristic time constant of ordering deterioration estimated from the residual ordering layer, we found that the hopping rates of Ge and the host atoms are in the same order of magnitude, indicating that di-vacancies are bound in the vicinity of Ge atoms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RoboPol: first season rotations of optical polarization plane in blazars

Here, we present first results on polarization swings in optical emission of blazars obtained by RoboPol, a monitoring programme of an unbiased sample of gamma-ray bright blazars specially designed for effective detection of such events. A possible connection of polarization swing events with periods of high activity in gamma-rays is investigated using the data set obtained during the first season of operation. It was found that the brightest gamma-ray flares tend to be located closer in time to rotation events, which may be an indication of two separate mechanisms responsible for the rotations. Blazars with detected rotations during non-rotating periods have significantly larger amplitude and faster variations of polarization angle than blazars without rotations. Our simulations show that the full set of observed rotations is not a likely outcome (probability ≤1.5 × 10 -2 ) of a random walk of the polarization vector simulated by a multicell model. Furthermore, it is highly unlikely (~5 × 10 -5 ) that none of our rotations is physically connected with an increase in gamma-ray activity.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic dipole γ-ray strength functions in the crossover from spherical to deformed neodymium isotopes

We calculate the magnetic dipole $\gamma$-ray strength functions in a chain of even-mass neodymium isotopes $^{144-152}$Nd in the framework of the configuration-interaction (CI) shell model. We infer the strength function by applying the maximum entropy method (MEM) to the exact imaginary-time response function calculated with the shell-model Monte Carlo (SMMC) method. The success of the MEM depends on the choice of a good strength function as a prior distribution. We investigate two choices for the prior strength function: the static path approximation (SPA) and the quasiparticle random-phase approximation (QRPA). We find that the QRPA is a better approximation at low temperatures (i.e., near the ground state), while the SPA is a better choice at finite temperatures. We identify a low-energy enhancement (LEE) in the MEM deexcitation $M1$ strength functions of the even-mass neodymium isotopes and compare with recent experimental results for the total deexcitation $\gamma$-ray strength functions. The LEE is already seen in the SPA strength function but not in the QRPA strength function, indicating the importance of large-amplitude static fluctuations around the mean field in reproducing the LEE. Our method is currently the only one which can reproduce LEE in heavy open-shell nuclei where conventional CI shell model calculations are prohibited. With the onset of deformation as number of neutrons increases along the chain of neodymium isotopes, we observe that some of the LEE strength transfers to a low-energy excitation, which we interpret as a finite-temperature ``scissors'' mode. Here, we also observe a finite-temperature spin-flip mode.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mean-field control for efficient mixing of energy loads

In this work, we pose an engineering challenge of controlling an ensemble of energy devices via coordinated, implementation-light, and randomized on/off switching as a problem in nonequilibrium statistical mechanics. We show that mean-field control with nonlinear feedback on the cumulative consumption, assumed available to the aggregator via direct physical measurements of the energy flow, allows the ensemble to recover from its use in the demand response regime, i.e., transition to a statistical steady state, significantly faster than in the case of the fixed feedback. Moreover when the nonlinearity is sufficiently strong, one observes the phenomenon of “super-relaxation,” where the total instantaneous energy consumption of the ensemble transitions to the steady state much faster than the underlying probability distribution of the devices over their state space, while also leaving almost no devices outside of the comfort zone.

25 ENERGY STORAGE↗

Effect of correlated oxide electrodes on disorder pinning and thermal roughening of ferroelectric domain walls in epitaxial PbZr 0.2 Ti 0.8 O 3 thin films

We report the competing effects of disorder pinning and thermal roughening on ferroelectric domain walls as a function of temperature in epitaxial PbZr 0.2 Ti 0.8 O 3 thin films deposited on (001) SrTiO 3 substrates buffered by three types of correlated oxide electrodes, La 0.67 Sr 0.33 MnO 3 , LaNiO 3 , and SrIrO 3 . Piezo-response force microscopy studies show that the 50 nm PbZr 0.2 Ti 0.8 O 3 films are uniformly polarized in the as-grown states, with the patterned domain structures persisting above 700 °C. For all three types of films, the domain wall roughness is dominated by 2D random bond disorder at room temperature, and transitions to 1D thermal roughening upon heating. The roughness exponent ζ increases progressively from 0.3 to 0.5 within a temperature window that depends on the bottom conducting oxide type, from which we extracted the distribution of disorder pinning energy. Lastly, we discuss the possible origins of the disorder pinning and the effect of the correlated oxide electrodes on the energy landscape of DW motion.

36 MATERIALS SCIENCE↗