Search NASA⌕ Search

SEARCH · Search NASA

Results for “reduced set methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

SU-E-I-29: Care KV: Dose It Influence Radiation Dose in Non-Contrast Examination of CT Abdomen/pelvis?

Purpose: CARE kV is a tool that automatically recommends optimal kV setting for individual patient for specific CT examination. The use of CARE kV depends on topogram and the user-selected contrast behavior. CARE kV is expected to reduce radiation dose while improving image quality. However, this may work only for certain groups of patients and/or certain CT examinations. This study is to investigate the effects of CARE kV on radiation dose of non-contrast examination of CT abdomen/pelvis. Methods: Radiation dose (CTDIvol and DLP) from patients who underwent abdomen/pelvis non-contrast examination with and without CARE kV were retrospectively reviewed. All patients were scanned in the same scanner (Siemens Somatom AS64). To mitigate any possible influences due to technologists’ unfamiliarity with the CARE kV, the data with CARE kV were retrieved 1.5 years after the start of CARE kV usage. T-test was used for significant difference in radiation dose. Results: Volume CTDIs and DLPs from 18 patients before and 24 patients after the use of CARE kV were obtained in a duration of one month. There is a slight increase in both average CTDIvol and average DLP with CARE kV compared to those without CARE kV (25.52 mGy vs. 22.65 mGy for CTDIvol; 1265.81 mGy-cm vs. 1199.19 mGy-cm). Statistically there was no significant difference. Without CARE kV, 140 kV was used in 9 of 18 patients, while with CARE KV, 140 kV was used in 15 of 24 patients. 80kV was not used in either group. Conclusion: The use of CARE kV may save time for protocol optimization and minimize variability among technologists. Radiation dose reduction was not observed in non-contrast examinations of CT abdomen/pelvis. This was partially because our CT protocols were tailored according to patient size before CARE kV and partially because of large size patients.

60 APPLIED LIFE SCIENCES↗

Adiabatic representation for a hydrogen atom photoionization in a uniform magnetic field

A new effective method of calculating wave functions of discrete and continuous spectra of a hydrogen atom in a strong magnetic field is developed on the basis of the adiabatic approach to parametric eigenvalue problems in spherical coordinates. The two-dimensional spectral problem for the Schroedinger equation at a fixed magnetic quantum number and parity is reduced to a spectral parametric problem for a one-dimensional angular equation and a finite set of ordinary second-order radial differential equations. The results are in good agreement with the photoionization calculations by other authors and have a true threshold behavior.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Histogram-Free Multicanonical Monte Carlo Algorithm for the Basis Expansion of Density of States

We report a new multicanonical Monte Carlo (MC) algorithm to obtain the density of states (DOS) for physical systems with continuous state variables in statistical mechanics. Our algorithm is able to obtain an analytical form for the DOS expressed in a chosen basis set, instead of a numerical array of finite resolution as in previous variants of this class of MC methods such as the multicanonical (MUCA) sampling and Wang-Landau (WL) sampling. This is enabled by storing the visited states directly in a data set and avoiding the explicit collection of a histogram. This practice also has the advantage of avoiding undesirable artificial errors caused by the discretization and binning of continuous state variables. Our results show that this scheme is capable of obtaining converged results with a much reduced number of Monte Carlo steps, leading to a significant speedup over existing algorithms.

97 MATHEMATICS AND COMPUTING↗

Adjoint Waveform Tomography for Crustal and Upper Mantle Structure the Middle East and Southwest Asia for Improved Waveform Simulations Using Openly Available Broadband Data

We present a new model of radially anisotropic seismic wavespeeds for the crust and upper mantle of a broad region of the Middle East and Southwest Asia (MESWA) derived from adjoint waveform tomography. We inverted waveforms from 192 Global Centroid Moment Tensor earthquakes (MW 5.5-7.0) recorded by over 1000 openly available broadband seismic stations from permanent and temporary networks in the region. Spatial coverage of the available data is highly uneven due to earthquakes clustered along plate boundaries and sparse coverage of open seismic networks in the region. We considered three possible starting models: the SPiRaL global model (Simmons et al., 2021); MEC-1 (Kaviani et al., 2020); and CSEM2.0 (Noe et al., 2023). Because the SPiRaL model provides good fits to the observed waveforms measured by the time-bandwidth product of selected windows in several period bands, provides all the necessary parameters and covers the entire domain we used it for the starting model with the period band 50-100 seconds. Inversion iterations proceeded using time-frequency phase misfits in six stages and 54 total iterations reducing the minimum period to 30 seconds. Our final model, MESWA, provides improved waveform fits compared to the starting model for both the data used in the inversion and an independent validation data set of 66 events. Two metrics of waveform fit (the time-frequency phase misfit used in the optimization and normalized L2 misfit) were both reduced by nearly 60% for both data sets and MESWA provides significantly larger misfit reductions relative to the SPiRaL model than the MEC-1 or CSEM models. We also find that MESWA provides a larger time-bandwidth product of selected windows indicating that more information content of the observed waveforms is explained by MESWA than the other models. Our new model reveals tectonic features imaged by other studies and methods but in a new holistic model of shear and compressional wavespeeds (v S and v P , respectively) with anisotropy covering the crust and uppermost mantle of a larger domain. MESWA has smaller scale-length features and tends to sharpen some features relative to the SPiRaL starting model. Examples include: low crustal v S in the TurkishIranian Plateau, Zagros Mountains, Afghan Central Blocks and Sulaiman Fold Belt; low mantle vSfollowing divergent (Gulf of Aden, Red Sea) and transform (Dead Sea Fault) margins of the Arabian Plate; low and high v S in the mantle beneath the Arabian Shield and Platform, respectively. Low vS is imaged below Cenozoic volcanic centers of the Arabian Peninsula, the so-called Mecca-Madina-Nafud (MMN) Line. Positive anisotropy (v SH > v SV ) is inferred for asthenospheric depths across the region except where up/downwelling may influence fabric alignment (e.g. Afar, Red Sea, Arabian Shield). Elevated vS tracks Makran subduction under southeast Iran. MESWA resembles the SPiRaL model in its long-wavelength structure, but enhances shorter wavelengths features on the order of 200 km and smaller. The resulting model could be used for as a starting model for further improvements, say using waveforms from in-country seismic networks that are not openly available or smaller-scale studies targeting shorter period waveforms. The model also could be used for source characterization and moment tensor inversion to improve earthquake hazard studies and nuclear explosion monitoring.

58 GEOSCIENCES↗

Quality Analysis of Baseline Time-Lapse CSEM Data CarbonSAFE Project, North Dakota

Conference presentation at International Meeting for Applied Geoscience & Energy (IMAGE), Houston, TX, August 28 – September 2, 2022. When a series of time-lapse CSEM surveys are designed to measure the often-small variations in signal seen in CCUS projects, the primary concern must be collecting the highest-quality data and reducing as much noise as possible. This includes optimization during planning and feasibility, careful and consistent quality checks in the field, and transparent and repeatable postprocessing steps. We apply this practice to a baseline (prior to CO 2 injection) CSEM data set collected for a time-lapse survey in Center, North Dakota, as a part of the North Dakota CarbonSAFE project, and describe the rigorous quality control and assessment methods used, including noise removal and data validation with 1D and 3D inversion to tie results to borehole logs. The final result is an accurate and representative CSEM data set and information that stakeholders can use to inform future time-lapse survey costs and designs.

20 FOSSIL-FUELED POWER PLANTS↗

Conotoxin Prediction: New Features to Increase Prediction Accuracy

Conotoxins are toxic, disulfide-bond-rich peptides from cone snail venom that target a wide range of receptors and ion channels with multiple pathophysiological effects. Conotoxins have extraordinary potential for medical therapeutics that include cancer, microbial infections, epilepsy, autoimmune diseases, neurological conditions, and cardiovascular disorders. Despite the potential for these compounds in novel therapeutic treatment development, the process of identifying and characterizing the toxicities of conotoxins is difficult, costly, and time-consuming. This challenge requires a series of diverse, complex, and labor-intensive biological, toxicological, and analytical techniques for effective characterization. While recent attempts, using machine learning based solely on primary amino acid sequences to predict biological toxins (e.g., conotoxins and animal venoms), have improved toxin identification, these methods are limited due to peptide conformational flexibility and the high frequency of cysteines present in toxin sequences. This results in an enumerable set of disulfide-bridged foldamers with different conformations of the same primary amino acid sequence that affect function and toxicity levels. Consequently, a given peptide may be toxic when its cysteine residues form a particular disulfide-bond pattern, while alternative bonding patterns (isoforms) or its reduced form (free cysteines with no disulfide bridges) may have little or no toxicological effects. Similarly, the same disulfide-bond pattern may be possible for other peptide sequences and result in different conformations that all exhibit varying toxicities to the same receptor or to different receptors. We present here new features, when combined with primary sequence features to train machine learning algorithms to predict conotoxins, that significantly increase prediction accuracy.

collisional cross section↗

State vector formulation of substructure coupling for damped systems

A generalized substructure coupling procedure in state vector form is derived for a complex system with general viscous damping. This first-order differential equation formulation is used in order to permit complex substructure modes to be employed easily. The free-interface normal (complex) modes and rigid-body modes of the substructure are defined. Complex residual attachment modes which result from static approximation of neglected higher modes are derived. The motion of each substructure is represented by a selected set of component modes. Equations of interface compatibility are employed to obtain an independent set of system equations of motion. A new method which employs incomplete complex normal modes in conjunction with the complex residual attachment modes to account for the contribution of neglected higher order modes is derived. Examples are employed to indicate how a damped structure may be analyzed by including the effect of residual attachment modes. Numerical results indicate that the new component mode synthesis method provides sytem equations of motion with reduced number of degrees of feedom leading to more accurate approximations to the system frequencies and damping factors than are obtained by pure mode truncation.

Chung, Y.-T.↗

Sea ice classification using fast learning neural networks

A first learning neural network approach to the classification of sea ice is presented. The fast learning (FL) neural network and a multilayer perceptron (MLP) trained with backpropagation learning (BP network) were tested on simulated data sets based on the known dominant scattering characteristics of the target class. Four classes were used in the data simulation: open water, thick lossy saline ice, thin saline ice, and multiyear ice. The BP network was unable to consistently converge to less than 25 percent error while the FL method yielded an average error of approximately 1 percent on the first iteration of training. The fast learning method presented can significantly reduce the CPU time necessary to train a neural network as well as consistently yield higher classification accuracy than BP networks.

Dawson, M. S.↗

Revision of the Dobson total ozone series at Hohenpeissenberg

Total ozone measurements with the Dobson No. 104 (D 104) have been performed at the Meteorological Observatory Hohenpeissenberg since 1967. A critical review of this time series and the comparison with other instruments like TOMS or Brewer spectrophotometer revealed some intervals with uncertainties. Especially in the early eighties a monthly mean bias of about minus 3 percent to TOMS-data with annual variations depending on the mean sun-height exists. An extreme amplitude of 5.6 percent occurs in 1980 with minus 0.76 percent (February) and minus 6.36 percent (July). Two different methods were applied to reprocess the Dobson data set. A comparison of the differently recalculated data showed, that the application of N-corrections by means of the standard-lamp tests starting from the reference values of the Arosa Intercomparison 1986 yields better results than the N-corrections based on a Langley-pilot of the Arosa Intercomparison 1978. The extreme amplitude of the year 1980 is now reduced to 3.02 percent. There is still a slight drift in the monthly and yearly mean differences between TOMS and revised Dobson data. It cannot be excluded, that the satellite data may be responsible for the trend.

Koehler, U.↗

Numerical Simulation of Shock-Induced Combustion Past Blunt Bodies Using Shock-Fitting Technique

Two-dimensional axisymmetric, reacting viscous flow over blunt projectiles is computed to study shock induced combustion at Mach 5.11 and Mach 6.46 in hydrogen-air mixture. A finite-difference, shock-fitting method is used to solve the complete set of Navier Stokes and species conservation equations. In this approach, the bow shock represents a boundary of the computational domain and is treated as a discontinuity across which Rankine-Hugoniot conditions are applied. All interior details of the flow such as compression waves, reaction front, and the wall boundary layer are captured automatically in the solution. Since shock-fitting approach reduces the amount of artificial dissipation, all the intricate details of the flow are captured much more clearly than has been possible with the shock-capturing approach. This has allowed an improved understanding of the physics of shock-induced combustion over blunt projectiles and the numerical results can now be explained more readily with one dimensional wave-interaction model than before.

Ahuja, J. K.↗

Prediction of Cognitive States During Flight Simulation Using Multimodal Psychophysiological Sensing

The Commercial Aviation Safety Team found the majority of recent international commercial aviation accidents attributable to loss of control inflight involved flight crew loss of airplane state awareness (ASA), and distraction was involved in all of them. Research on attention-related human performance limiting states (AHPLS) such as channelized attention, diverted attention, startle/surprise, and confirmation bias, has been recommended in a Safety Enhancement (SE) entitled "Training for Attention Management." To accomplish the detection of such cognitive and psychophysiological states, a broad suite of sensors was implemented to simultaneously measure their physiological markers during a high fidelity flight simulation human subject study. Twenty-four pilot participants were asked to wear the sensors while they performed benchmark tasks and motion-based flight scenarios designed to induce AHPLS. Pattern classification was employed to predict the occurrence of AHPLS during flight simulation also designed to induce those states. Classifier training data were collected during performance of the benchmark tasks. Multimodal classification was performed, using pre-processed electroencephalography, galvanic skin response, electrocardiogram, and respiration signals as input features. A combination of one, some or all modalities were used. Extreme gradient boosting, random forest and two support vector machine classifiers were implemented. The best accuracy for each modality-classifier combination is reported. Results using a select set of features and using the full set of available features are presented. Further, results are presented for training one classifier with the combined features and for training multiple classifiers with features from each modality separately. Using the select set of features and combined training, multistate prediction accuracy averaged 0.64 +/- 0.14 across thirteen participants and was significantly higher than that for the separate training case. These results support the goal of demonstrating simultaneous real-time classification of multiple states using multiple sensing modalities in high fidelity flight simulators. This detection is intended to support and inform training methods under development to mitigate the loss of ASA and thus reduce accidents and incidents.

Harrivel, Angela R.↗

A histogram-free multicanonical Monte Carlo algorithm for the construction of analytical density of states

We report a new multicanonical Monte Carlo (MC) algorithm to obtain the density of states (DOS) for physical systems with continuous state variables in statistical mechanics. Our algorithm is able to obtain an analytical form for the DOS expressed in a chosen basis set, instead of a numerical array of finite resolution as in previous variants of this class of MC methods such as the multicanonical (MUCA) sampling and Wang-Landau (WL) sampling. This is enabled by storing the visited states directly in a data set and avoiding the explicit collection of a histogram. This practice also has the advantage of avoiding undesirable artificial errors caused by the discretization and binning of continuous state variables. Our results show that this scheme is capable of obtaining converged results with a much reduced number of Monte Carlo steps, leading to a significant speedup over existing algorithms.

Li, Ying Wai↗

Adsorption Modeling at the Front and Back Ends of the Nuclear Fuel Cycle

Adsorption is a diverse and complex physicochemical process that has many different applications in chemical, environmental, and nuclear sciences. For example, adsorption can be found at both the front and back ends of the nuclear fuel cycle for (i) capturing uranium from seawater to use as a new source of nuclear fuel and (ii) treatment of the off-gases produced when reprocessing used nuclear fuel. Accurate modeling of these processes is important for the design of efficient capture, recovery, and removal systems for the particular aqueous or gaseous species of interest. A set of algorithms and methods designed for flexibility and portability will greatly improve the ability to rigorously model such a complex set of systems. This approach allows more specific models to be built upon the more generic methods, which gives the overall modeling effort larger breadth and greater usability. Due to the complexity of adsorption processes, it is necessary to develop relatively complex mechanistic models to accurately predict the behavior of engineered adsorption systems. Capture and recovery systems designed for nuclear energy need to have a high level of accuracy to reduce uncertainties and aid in the implementation of separations technologies for efficient nuclear energy systems. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Flow Visualization for the Separation of Air-water Bubbly Two-phase Flow Through a Vertical T-junction

T-junction is a typical structure in many industrial systems such as power plants, chemical process, and hydrocarbon production industries. The separation of two-phase flow passing through T-junction is a common flow phenomenon. There are lots of investigations regarding two-phase flow separation in branching tees and wyes tees. The characteristic of the two-phase flow between the two outlets are always non-uniform, and this kind of fluid status may contribute to the unpredictable damage of downstream facilities. For the nuclear power plants, severe accidents analysis is important especially for Light-Water Reactors (LWR) when Loss of Coolant Accident (LOCA) occurs. The small break of the pipe may cause the coolant become two-phase flow due to the pressure drop. Under certain conditions, the behavior of T-junction is similar to a gas-liquid separator, as a result of the gas enters the side arm and the liquid flows straight along the run arm. The partial separation of gas-liquid mixtures can reduce the load on the main separator, probably leading to smaller units. The study aims to establish complete visual observations for the benchmark of Computational Fluid Dynamics (CFD) model. As a consequence, a vertical T-junction (D = 26 mm) experimental loop was set up for the purpose of elaborating the complex two-phase fluid phenomena. In this experiment, variables were manipulated under highly controlled conditions and a photographic method was proposed to analyze the images of phase separation. Furthermore, the images obtained by camera have been discussed to receive valuable information about the two phase flow behavior around the T-junction.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Computer-aided detection of breast masses: Four-view strategy for screening mammography

Purpose: To improve the performance of a computer-aided detection (CAD) system for mass detection by using four-view information in screening mammography. Methods: The authors developed a four-view CAD system that emulates radiologists' reading by using the craniocaudal and mediolateral oblique views of the ipsilateral breast to reduce false positives (FPs) and the corresponding views of the contralateral breast to detect asymmetry. The CAD system consists of four major components: (1) Initial detection of breast masses on individual views, (2) information fusion of the ipsilateral views of the breast (referred to as two-view analysis), (3) information fusion of the corresponding views of the contralateral breast (referred to as bilateral analysis), and (4) fusion of the four-view information with a decision tree. The authors collected two data sets for training and testing of the CAD system: A mass set containing 389 patients with 389 biopsy-proven masses and a normal set containing 200 normal subjects. All cases had four-view mammograms. The true locations of the masses on the mammograms were identified by an experienced MQSA radiologist. The authors randomly divided the mass set into two independent sets for cross validation training and testing. The overall test performance was assessed by averaging the free response receiver operating characteristic (FROC) curves of the two test subsets. The FP rates during the FROC analysis were estimated by using the normal set only. The jackknife free-response ROC (JAFROC) method was used to estimate the statistical significance of the difference between the test FROC curves obtained with the single-view and the four-view CAD systems. Results: Using the single-view CAD system, the breast-based test sensitivities were 58% and 77% at the FP rates of 0.5 and 1.0 per image, respectively. With the four-view CAD system, the breast-based test sensitivities were improved to 76% and 87% at the corresponding FP rates, respectively. The improvement was found to be statistically significant (p<0.0001) by JAFROC analysis. Conclusions: The four-view information fusion approach that emulates radiologists' reading strategy significantly improves the performance of breast mass detection of the CAD system in comparison with the single-view approach.

60 APPLIED LIFE SCIENCES↗

Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: A digital phantom study

Purpose: Prospective respiratory-gated 4D CT has been shown to reduce tumor image artifacts by up to 50% compared to conventional 4D CT. However, to date no studies have quantified the impact of gated 4D CT on normal lung tissue imaging, which is important in performing dose calculations based on accurate estimates of lung volume and structure. To determine the impact of gated 4D CT on thoracic image quality, the authors developed a novel simulation framework incorporating a realistic deformable digital phantom driven by patient tumor motion patterns. Based on this framework, the authors test the hypothesis that respiratory-gated 4D CT can significantly reduce lung imaging artifacts. Methods: Our simulation framework synchronizes the 4D extended cardiac torso (XCAT) phantom with tumor motion data in a quasi real-time fashion, allowing simulation of three 4D CT acquisition modes featuring different levels of respiratory feedback: (i) “conventional” 4D CT that uses a constant imaging and couch-shift frequency, (ii) “beam paused” 4D CT that interrupts imaging to avoid oversampling at a given couch position and respiratory phase, and (iii) “respiratory-gated” 4D CT that triggers acquisition only when the respiratory motion fulfills phase-specific displacement gating windows based on prescan breathing data. Our framework generates a set of ground truth comparators, representing the average XCAT anatomy during beam-on for each of ten respiratory phase bins. Based on this framework, the authors simulated conventional, beam-paused, and respiratory-gated 4D CT images using tumor motion patterns from seven lung cancer patients across 13 treatment fractions, with a simulated 5.5 cm{sup 3} spherical lesion. Normal lung tissue image quality was quantified by comparing simulated and ground truth images in terms of overall mean square error (MSE) intensity difference, threshold-based lung volume error, and fractional false positive/false negative rates. Results: Averaged across all simulations and phase bins, respiratory-gating reduced overall thoracic MSE by 46% compared to conventional 4D CT (p ∼ 10{sup −19}). Gating leads to small but significant (p < 0.02) reductions in lung volume errors (1.8%–1.4%), false positives (4.0%–2.6%), and false negatives (2.7%–1.3%). These percentage reductions correspond to gating reducing image artifacts by 24–90 cm{sup 3} of lung tissue. Similar to earlier studies, gating reduced patient image dose by up to 22%, but with scan time increased by up to 135%. Beam paused 4D CT did not significantly impact normal lung tissue image quality, but did yield similar dose reductions as for respiratory-gating, without the added cost in scanning time. Conclusions: For a typical 6 L lung, respiratory-gated 4D CT can reduce image artifacts affecting up to 90 cm{sup 3} of normal lung tissue compared to conventional acquisition. This image improvement could have important implications for dose calculations based on 4D CT. Where image quality is less critical, beam paused 4D CT is a simple strategy to reduce imaging dose without sacrificing acquisition time.

60 APPLIED LIFE SCIENCES↗

USEtox - The UNEP-SETAC toxicity model: recommended characterisation factors for human toxicity and freshwater ecotoxicity in Life Cycle Impact Assessment

Background, Aim and Scope. In 2005 a comprehensive comparison of LCIA toxicity characterisation models was initiated by the UNEP-SETAC Life Cycle Initiative, directly involving the model developers of CalTOX, IMPACT 2002, USES-LCA, BETR, EDIP, WATSON, and EcoSense. In this paper we describe this model-comparison process and its results--in particular the scientific consensus model developed by the model developers. The main objectives of this effort were (i) to identify specific sources of differences between the models' results and structure, (ii) to detect the indispensable model components, and (iii) to build a scientific consensus model from them, representing recommended practice. Methods. A chemical test set of 45 organics covering a wide range of property combinations was selected for this purpose. All models used this set. In three workshops, the model comparison participants identified key fate, exposure and effect issues via comparison of the final characterisation factors and selected intermediate outputs for fate, human exposure and toxic effects for the test set applied to all models. Results. Through this process, we were able to reduce inter-model variation from an initial range of up to 13 orders of magnitude down to no more than 2 orders of magnitude for any substance. This led to the development of USEtox, a scientific consensus model that contains only the most influential model elements. These were, for example, process formulations accounting for intermittent rain, defining a closed or open system environment, or nesting an urban box in a continental box. Discussion. The precision of the new characterisation factors (CFs) is within a factor of 100-1000 for human health and 10-100 for freshwater ecotoxicity of all other models compared to 12 orders of magnitude variation between the CFs of each model respectively. The achieved reduction of inter-model variability by up to 11 orders of magnitude is a significant improvement.Conclusions. USEtox provides a parsimonious and transparent tool for human health and ecosystem CF estimates. Based on a referenced database, it has now been used to calculate CFs for several thousand substances and forms the basis of the recommendations from UNEP-SETAC's Life Cycle Initiative regarding characterization of toxic impacts in Life Cycle Assessment. Recommendations and Perspectives. We provide both recommended and interim (not recommended and to be used with caution) characterisation factors for human health and freshwater ecotoxicity impacts. After a process of consensus building among stakeholders on a broad scale as well as several improvements regarding a wider and easier applicability of the model, USEtox will become available to practitioners for the calculation of further CFs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗